ultrasonic level transmitter ult200h
TRANSCRIPT
Page 1 of 2
Non contact type, continuous level measurement with no moving parts.•Measures liquid height, distance to liquid, volume or flow in open•
channels.
Two wire direct current loop powered.• Narrow beam technology.• Self diagnostic function i.e error messages on display provided•
to ease settings up.
Automatic temperature compensation.• Local display 8 X 1 LCD• Instrument configuration settings are password protected.• Process down time minimized.• Software calibration.• Compact size & easy maintenance.•
2 WIRE ULTRASONIC LEVEL TRANSMITTERULT-200 / ULT 200H
ELECTRONET
SALIENT FEATURES
DESCRIPTION
TECHNICAL SPECIFICATIONS
Electronet series ULT-200 / ULT-200H are 2 wire Ultrasonic level transmitters designed for non contact type level measurement. Ultrasonic level measurement is based on the time required by ultrasonic pulses to travel from sensor to the surface of liquid & back to sensor. Ultrasonic level transmitters are the best for applications such as slurries, corrosive liquids & waste water. The transmitter provides 4-20 mA DC continuous output with local indication through LCD. The measuring range is available from 0.6 to 12 mtrs.
Measurement Principle : Ultrasonic, time of flight Measuring Range : 0.6 to 12 mtrs.Type of Output : 4-20 mA DC, 2 wirePower Supply : 24 V DC, ExternalPower Consumption : < 500 mWDead Band : 0.6 mtrDisplay : Local display 8X1 LCDAccuracy : ± 0.25% of F. S.Process Temperature : -30 to 80 °COperating Pressure : AtmosphericBeam Angle : < 8°Response Time : < 500 msMeasuring Frequency : 25 kHzTemperature Coefficient : ± 0.01% per °CEnclosure : Weather-proof, IP-65, Aluminium die cast typeProcess Connection : 2” BSP (M) ThreadedMounting : Top of the tankWeight : 1.5 kgOperating Conditions : Temperature 0 to 55 °C / Humidity 5 to 95% non condensingProduct description : Two wire compact type ultrasonic level transmitterMaterial of construction : Aluminium die cast typeSensor Ingress Protection : IP-65
CAT/ULT-200-R1
60
(±1
)mm
38
(±1
)mm
12(±1)mm
12(±1)mm
131(±
1)m
m
ULT 200
P
137(± 1)mm
60
(± 1
)mm
38
(± 1
)mm
12(± 1)mm
12(± 1)mm
205(± 1)mm
131(±
1)m
m
ULT 200
P
Page 2 of 2
ORDERING INFORMATION
*Accuracy defined at lab conditions.
*Due to our continuous product revisions, Design, Specifications and Model Number are subject to change without notice.
SERIES
65 mm01
01
Probe Length
A
Upto 12mtr
CAT/ULT-200-R1
ULT-200
LOOP DIAGRAM
POWER SUPPLY Vs LOAD GRAPH
16 18 24 30 36 420
250
500
750
1000
1250
1500
With HART Communication
Without HART Communication
500 ohms
1200 ohms
Power Supply Load limitation
Lo
ad
, o
hm
s
65 mm02
01
02
Output
B
4-20mA
4-20 mA with HART
DIMENSIONAL DRAWING INSTALLATION DETAIL
LOOP DIAGRAM
4-20mA Output
Input Device
Sensor
HART Communicator
SensorSignal
An
alo
g O
utp
ut
Output Device
Le
ve
l
EmptyLevel
Transmitter ElectronicsModule
Microprocessor Digital PV
Deadband
Le
ve
l
Empty
4.00mA
20.00mA
Level
Beam Angle
<
7°
ULT 200
P
NK Instruments Pvt Ltd501-504, Raunak Arcade, Near THC Hospital, Gokhale Road,Thane - W 400602, Maharashtra, India. Contact: 91-22-25301330/31/32Email : [email protected] Website: www.nkinstuments.com
Authozied Dealer