1 /59 Chhattisgarh State Industrial Development Corporation Limited (A Government of Chhattisgarh Undertaking) LIC Campus, Pandri Raipur 492 004 (C.G) Phone 91-771-2583789-90, Fax : 91-771-2583794, 4091879 Website: www.csidc.in, Email : [email protected], [email protected] No./CSIDC/MKD/ PS- II / 12-13/ Raipur, Dated : LIST OF PARALLEL RATE CONTRACT FOR ITEM- UPS System S.No. Name of Unit Valid upto Rate Contract No 1 M/s. Power Generation E-94, Sector-1, Devendra Nagar B/o Mahalaxmi Cloth Market Pandri Raipur -492001 Pho. No.- 0771-2110028 , 9425205059, Toll free - 18002335090 26.09.2012 to 25.09.2013 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/PG/4225 2 M/s. RS Power System H1-85, RIICO Industrial Area Mansarovar, Jaipur-302020 Pho. 0141-2396550, 2395860 Fax- 0141-2395860 26.09.2012 to 25.09.2013 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/RS/4226 3 M/s. Cyber Net Shop No-177 & 178 , Sector -6 "E" Market, Bhilai Distt-Durg (C.G.) Mob- 9826161015 26.09.2012 to 25.09.2013 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/CN/4227 4 M/s. Global Network Solutions, C/13, Shailendra Nagar Raipur CG - 492001 Pho-07714094432, 8889871071 26.09.2012 to 25.09.2013 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/GN/4228 (Subas Chandra Bhagat ) I/c Marketing-I

Upload: suman94103

Post on 03-Nov-2014

88 views

Category:

Documents


3 download

DESCRIPTION

ups system

TRANSCRIPT

Page 1: ups system

1 /59 Chhattisgarh State Industrial Development Corporation Limited (A Government of Chhattisgarh Undertaking) LIC Campus, Pandri Raipur 492 004 (C.G) Phone 91-771-2583789-90, Fax : 91-771-2583794, 4091879 Website: www.csidc.in, Email : [email protected], [email protected]

No./CSIDC/MKD/ PS- II / 12-13/ Raipur, Dated :

LIST OF PARALLEL RATE CONTRACT FOR ITEM-

UPS System

S.No. Name of Unit Valid upto Rate Contract No 1 M/s. Power Generation

E-94, Sector-1, Devendra Nagar B/o Mahalaxmi Cloth Market Pandri Raipur -492001 Pho. No.- 0771-2110028 , 9425205059, Toll free - 18002335090

26.09.2012 to 25.09.2013 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/PG/4225

2 M/s. RS Power System H1-85, RIICO Industrial Area Mansarovar, Jaipur-302020 Pho. 0141-2396550, 2395860 Fax- 0141-2395860

26.09.2012 to 25.09.2013 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/RS/4226

3 M/s. Cyber Net Shop No-177 & 178 , Sector -6 "E" Market, Bhilai Distt-Durg (C.G.) Mob- 9826161015

26.09.2012 to 25.09.2013 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/CN/4227

4 M/s. Global Network Solutions, C/13, Shailendra Nagar Raipur CG -492001 Pho-07714094432, 8889871071

26.09.2012 to 25.09.2013 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/GN/4228

(Subas Chandra Bhagat )

I/c Marketing-I

Page 2: ups system

2 /59 Chhattisgarh State Industrial Development Corporation Limited (A Government of Chhattisgarh Undertaking) LIC Campus, Pandri Raipur 492 004 (C.G) Phone 91-771-2583789-90, Fax : 91-771-2583794, 4091879 Website: www.csidc.in, Email : [email protected], [email protected]

No./CSIDC/MKD/ PS- II / 12-13/ Raipur, Dated : Registered A/D Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/PG/4225 Dated: 26.09.2012 To,

M/s. Power Generation E-94, Sector-1, Devendra Nagar B/o Mahalaxmi Cloth Market Pandri Raipur -492001 Pho. No.- 0771-2110028 , Toll free – 18002335090, 9425205059

Sub :- Rate Contract for the supply of Item UPS System (Valid From dated 26.09.2012 to 25.09.2013)

Ref :- (I) This Office Tender Enquiry No. CSIDC/MKD/ PS- II / 71-291/12-13 (II) Your Bid No. 5982 dated 24.07.2012 (III) Your Offer acceptance along with undertaking submitted on dated 20.09.2012

Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2 . The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction .

You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment . SCHEDULES ANNEXED : 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item UPS System

Item UPS System 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 15 pages

Yours faithfully,

(Subas Chandra Bhagat ) I/c Marketing-I

For and on behalf of the purchaser named in CSIDC Form No.2

Page 3: ups system

3 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/PG/4225 Dated: 26.09.2012 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .

2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .

3. The Accountant General Chhattisgarh State, Raipur.

4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC, pre dispatched inspection of stores, also acceptance of store and ensure to endorse the copy of purchase order (Indent) to the CSIDC Ltd., for further approval of authorized pre dispatch Inspection Agency enlisted in the CSIDC panel.

5. All The Collectors ,Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC, pre dispatched inspection of stores, acceptance of store and ensure to endorse the copy of purchase order (Indent) to the CSIDC Ltd., for further approval of authorized pre dispatch Inspection Agency enlisted in the CSIDC panel

6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control

7. (i) The Director Directorate of Public Instruction, Pension bada, Raipur (ii) The Director Directorate of Tribal welfare & Backward Classes ,Pt.R.S.U. Campus Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .

Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. release of supply order, inspection of stores, payment of bill whichever is applicable, as the responsibility rests with the concerned authority .

8. (i) ADG (Q & A) , DGS&D, Jeewan Tara Building 5 Parliament Street New Delhi 110001 (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor, Infront

of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Churchgate Station Road, Second Floor, M.K.

Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-

462011. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.

9. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file of Rate Contract.

10. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.

11. Main file of Item- UPS System

(Subas Chandra Bhagat )

I/c Marketing-I For and on behalf of the purchaser

Named in CSIDC Form No.2

Page 4: ups system

4 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/PG/4225 Dated: 26.09.2012

SCHEDULE “A” Description of Stores, Prices, Duties/Taxes

For the supply of Item- UPS System as per Annexure’A’ enclosed.

1. (a) NAME AND FULL ADDRESS OF :- M/s. Power Generation THE FIRM E-94, Sector-1, Devendra Nagar

Mahalaxmi Cloth Market Pandri Raipur -492001

NAME AND FULL ADDRESS OF M/s. Power Generation MANUFACTURER E-94, Sector-1, Devendra Nagar Mahalaxmi Cloth Market

Pandri Raipur -492001

(b1) CATEGORY :- General

2. VALIDITY OF RATE CONTRACT :- From 26.09.2012 to 25.09.2013 3. DESCRIPTION OF ITEM- UPS System SPECIFICATION, UNIT RATE AS BELOW

Item Code No. Item Description Class Rate FOR Dest.

ED &VAT/CST Extra As Applicable Rate Per Unit

1 2 3 Schedule1On-Line UPS with isolation transformer suitable for Three Phase AC Inputand Three Phase AC Output,Floor Mounted TypeUnit :NOS.Rating of UPS Indicative Back-Up time

UPS27001002 10 KVA / 60 minutes 164551.00 UPS27001004 15 KVA / 30 minutes 182864.00 UPS27001005 15 KVA / 60 minutes 229269.00 UPS27001006 15 KVA / 120 minutes 339528.00 UPS27001007 20 KVA / 30 minutes 223572.00 UPS27001008 20 KVA / 60 minutes 299996.00 UPS27001009 20 KVA / 120 minutes 458386.00 UPS27001010 30 KVA / 30 minutes 175680.00 UPS27001011 30 KVA / 60 minutes 370625.00 UPS27001012 30 KVA / 120 minutes 631731.00 Schedule-2 On-Line UPS with isolation transformer suitable for Three Phase AC Input and Single Phase AC Output,Floor Mounted Type Unit : NOS. Rating of UPS Indicative Back-Up time

UPS27001013 10 KVA / 30 minutes 104714.00 UPS27001014 10 KVA / 60 minutes 136899.00 UPS27001015 10 KVA / 120 minutes 191296.00 UPS27001016 15 KVA / 30 minutes 145965.00 UPS27001017 15 KVA / 60 minutes 178603.00 UPS27001018 15 KVA / 120 minutes 281958.00 UPS27001019 20 KVA / 30 minutes 161378.00 UPS27001020 20 KVA / 60 minutes 244786.00 UPS27001021 20 KVA / 120 minutes 389845.00 UPS27001022 30 KVA / 30 minutes 222121.00 UPS27001023 30 KVA / 60 minutes 351767.00 UPS27001024 30 KVA / 120 minutes 545784.00 Schedule4On-Line UPS with isolation transformer suitable for single phase AC input & single phase AC output, Floor Mounted TypeUnit :NOSating of UPS Indicative Back-up time

UPS27001043 5.0 KVA / 30 Minutes 55303.00 UPS27001044 5.0 KVA / 60Minutes 70716.00 UPS27001045 5.0 KVA / 120 Minutes 106980.00 UPS27001051 7.5 KVA / 120 Minutes 62733.00

(Subas Chandra Bhagat ) I/c Marketing-I

Page 5: ups system

5 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/PG/4225 Dated: 26.09.2012

Schedule5Line Interactive UPS with AVR for single phase AC 160V to 280V input.Unit :NOS.Specification:As per detailed specification and General Technical Requirements.Rated KVA Minimum VAH

UPS27001055 0.5 / 84 1469.00 UPS27001056 0.5 / 168 2457.00 UPS27001057 0.5 / 400 3826.00 UPS27001059 0.65 / 400 4170.00 UPS27001061 0.8 / 168 3055.00 UPS27001062 0.8 / 400 4597.00 UPS27001063 0.8 / 216 3581.00 UPS27001064 1.0 / 168 3654.00 UPS27001065 1.0 / 400 5553.00 UPS27001066 1.0 / 216 3762.00 UPS27001068 1.5 / 800 8794.00 UPS27001069 1.5 / 600 7797.00 UPS27001070 2.0 / 800 11015.00 UPS27001071 2.0 / 1600 13123.00 Schedule6Line Interactive UPS (CE or UL certified) with AVR for single phase AC160V to 280V input.Unit :NOS.Specification: As per detailed specification and General Technical Requirements.Rated KVA Minimum VAHRated KVA Minimum VAH

UPS27001072 0.5 / 84 1477.00 UPS27001073 0.5 / 168 2468.00 UPS27001074 0.5 / 400 3840.00 UPS27001075 0.65 / 168 2609.00 UPS27001076 0.65 / 400 4176.00 UPS27001077 0.65 / 108 2232.00 UPS27001078 0.8 / 168 3071.00 UPS27001079 0.8 / 400 4612.00 UPS27001080 0.8 / 216 3595.00 UPS27001081 1.0 / 168 3662.00 UPS27001082 1.0 / 400 5565.00 UPS27001083 1.0 / 216 4923.00 UPS27001084 1.0 / 800 7501.00 UPS27001088 2.0 / 1600 14055.00

Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination ( Any where in C.G.State ) 5. EXCISE DUTY : Extra as applicable 6. SALES TAX /VAT/CST : Extra as applicable

Tin No. 22761601616 Address:-

M/s. Power Generation E-94, Sector-1, Devendra Nagar Mahalaxmi Cloth Market Pandri Raipur -492001

7. DELIVERY PERIOD : With in 30 to 90 days 8. a. ANNUAL TURN OVER/ : 2006-07 Rs. 4000000

2007-08 Rs. 6000000 2008-09 Rs. 9000000

b. MONETARY LIMIT : NM

(Subas Chandra Bhagat ) I/c Marketing-I

Page 6: ups system

6 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/PG/4225 Dated: 26.09.2012 c. INSTALLED CAPACITY : (as per DTIC Registration Certificate) Description Capacity/Annum

UPS System 2000 Nos for 5 Items.

9. SLAB DISCOUNT (IF ANY) : Nil 10. PRICES : Prices are Firm and Final 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : Manufacturer

FIRM 13. REGISTRATION STATUS : Manufacturer is Registered with DTIC RAIPUR DTIC- 220111100888 dt 22.05.2009

14 BIS LICENSE : NM 15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding

Officers (DDOs). 16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each

consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .

17 INSPECTION AUTHORITY : Accorded by CSIDC Ltd. While receipt of copy of purchase Order(Indent) in Favour of authorized pre dispatched Inspection Agency enlisted in the CSIDC panel prior to submission of application from the Rate Contract Holders.

18 QUALITY ASSURANCE: a)Accorded by CSIDC Ltd. While receipt of copy of purchase

Order (Indent) in Favour of authorized pre dispatched Inspection Agency enlisted in the CSIDC panel prior to submission of application from the Rate Contract Holders.

b)Post-dispatch inspection by the committee constituted by the Direct Demanding Officers /Purchase Department .

OR Post Dispetch Inspection of Stores carried by the Inspection

Agency enlisted in the CSIDC prior to receiving of proposal from the end user/Purchase Department.

19. PLACE WHERE THE STORES At Manufacturer’s Factory at

ARE TO BE OFFERED FOR M/S. POWER GENERATION INSPECTION E-94, Sector-1, Devendra Nagar

Mahalaxmi Cloth Market Pandri Raipur -492001

(Subas Chandra Bhagat ) I/c Marketing-I

Page 7: ups system

7 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/PG/4225 Dated: 26.09.2012

20 INSPECTION CHARGES : Inspection charges 0.60%+ Service Tax As applicable to be

paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.

21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause

7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.

22. Special Note 1. Purchasing Departments will ensure pre dispatch inspection of Materials. 2. Purchasing Departments will be responsible for ensuring the Quality of accepted materials. 3. Purchasing Departments will ensure sending copy of every order to this office.

(Subas Chandra Bhagat ) I/c Marketing-I

Page 8: ups system

8 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/PG/4225 Dated: 26.09.2012

Annexure - “A” Technical Particulars For On-Line UPS For IT Applications Schedule 1 On-Line UPS with isolation transformer suitable for Three Phase AC Input and Three Phase AC Output,Floor Mounted Type Unit : NOS. Rating of UPS Indicative Back-Up time

UPS27001002 10 KVA / 60 minutes UPS27001004 15 KVA / 30 minutes UPS27001005 15 KVA / 60 minutes UPS27001006 15 KVA / 120 minutes UPS27001007 20 KVA / 30 minutes UPS27001008 20 KVA / 60 minutes UPS27001009 20 KVA / 120 minutes UPS27001010 30 KVA / 30 minutes UPS27001011 30 KVA / 60 minutes UPS27001012 30 KVA / 120 minutes

Schedule 2 On-Line UPS with isolation transformer suitable for Three Phase AC Input and Single Phase AC Output,Floor Mounted Type Unit : NOS. Rating of UPS Indicative Back-Up time

UPS27001013 10 KVA / 30 minutes UPS27001014 10 KVA / 60 minutes UPS27001015 10 KVA / 120 minutes UPS27001016 15 KVA / 30 minutes UPS27001017 15 KVA / 60 minutes UPS27001018 15 KVA / 120 minutes UPS27001019 20 KVA / 30 minutes UPS27001020 20 KVA / 60 minutes UPS27001021 20 KVA / 120 minutes UPS27001022 30 KVA / 30 minutes UPS27001023 30 KVA / 60 minutes UPS27001024 30 KVA / 120 minutes

Schedule 4 On-Line UPS with isolation transformer suitable for single phase AC input & single phase AC output, Floor Mounted Type Unit : NOS. Rating of UPS Indicative Back-up time

UPS27001043 5.0 KVA / 30 Minutes UPS27001044 5.0 KVA / 60Minutes UPS27001045 5.0 KVA / 120 Minutes UPS27001051 7.5 KVA / 120 Minutes

(M.A. Ansari ) Incharge PS-II

Page 9: ups system

9 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/PG/4225 Dated: 26.09.2012 Questionnaire Schedule On-Line UPS with isolation transformer suitable for Three Phase AC Input and Single Phase AC Output,Floor Mounted Type 1 Online UPS for IT application 1.1 Charging voltage (DC Bus Voltage) 1.2 Charging current 1.3 Switching device (MOSFET/IGBT) 1.4 Switching frequency (should be more than 10kHz) 1.5 Battery AH capacity 1.6 Battery voltage 1.7 No of batteries 1.8 Make/Model of batteries Questionnaire Schedule On-Line UPS with isolation transformer suitable for single phase AC input & single phase AC output, Floor Mounted Type 1. Online UPS for IT application 1.1 Charging voltage (DC Bus voltage) 1.2 Charging current 1.3 Switching device (MOSFET /IGBT) 1.4 Switching frequency( (should be more than 10kHz) 1.5 Battery AH capacity 1.6 Battery voltage 1.7 No of batteries 1.8 Make/Model of batteries Questionnaire Schedule On-Line UPS with isolation transformer suitable for Three Phase AC Input and Three Phase AC Output,Floor Mounted Type 1 Online UPS for IT application 1.1 Charging voltage (DC Bus Voltage) 1.2 Charging current 1.3 Switching device (MOSFET/IGBT) 1.4 Switching frequency (should be more than 10kHz) 1.5 Battery AH capacity 1.6 Battery voltage 1.7 No of batteries 1.8 Make/Model of batteries General Technical requirement For TE : 1. General a. UPS shall be free from workmanship defects, sharp edges, nicks, scratches, burs, etc. All fasteners shall be fixed properly. The equipment shall be complete with all parts and all parts shall be functional. b. Enclosures shall conform to protection requirement of IP2L1 to IS13947 (part 1)/1993 (reaffirmed 1998). c. By-pass facility shall be provided for maintenance of UPS. d. UPS shall supply output power and charging current at the same time. e. Switching device shall be MOSFET or IGBT and the same shall be confirm in the offer. f. Switching frequency shall be above 10 KHz and shall be declared in the offer. g. KW rating of the UPS shall be 0.70 times the KVA rating. 2. Input (as applicable) a. 160V-260V, 50 +/-3% Hz single phase AC or b. 300V-450V, 50 +/-3%Hz three phase AC

(M.A. Ansari )

Incharge PS-II

Page 10: ups system

10 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/PG/4225 Dated: 26.09.2012 3. Output (as applicable) a. 230V +/-1% (with alternative setting for 220V +/-1%) 50 +/-0.5Hz, single phase. b. 400V +/-1% (with alternative setting for 380V +/-1%) 50 +/-0.5Hz three phase. Voltage regulation from no load to full load shall be within +/-1% in both the cases. UPS shall also have facility for operation in synchronous mode in which output frequency shall be same as that of mains frequency. 4. Total harmonics distortion at output : 2% maximum for UPS up to 5KVA and 3% maximum for UPS above 5 KVA on resistive load. If total input harmonics are less than or equal to 10%. 5. Efficiency (at rated output voltage and frequency) a. Overall efficiency (minimum) : 90% 6. UPS power factor at rated load : better than 0.9 lagging. 7. Over load : UPS shall withstand 20% overload for 10 minutes and 50% over load for one minute. 8. Protections : Following protection shall be provided in UPS: a. Over voltage, short circuit, and overload at UPS output terminal. b. Under voltage at battery terminal. c. Over shoot and under shoot shall not be greater than 4% of rated voltage for duration of 40m sec. (maximum) 9. Indicators and meters a. Following indicators shall be provided:- (i) Mains presence. (ii) Battery charging and discharging (iii) Output overload (iv) Low battery voltage. b. Digital meter shall be provided for monitoring the following parameters in UPS(not applicable for rack mounting): (i) Input AC voltage. (ii) Output AC Voltage, current and frequency (iii) Battery voltage and current. 10. Battery bank: a. UPS shall be supplied with SMF VRLA battery only. b. Tenderers shall declare battery AH capacity, battery voltage, number of batteries of each rating, make and model of batteries offered with each item of UPS. c. Batteries for UPS shall be of the following makes:- Exide, Panasonic, Amar Raja, Global, Rocket ,Base, RITAR make & DGS&D registered batteries or any other make duly type tested to JIS C 8702 from DGS&D approved lab. d. The UPS shall be complete with Trolley for battery bank and the firms shall also connect the batteries with UPS and commission the same. e. Minimum VAH rating of battery bank for different duration of back up time shall be as detailed below: UPS rating Min.VAH Min. VAH Min VAH Min. VAH in KVA 30 minute 60 minute 120 minute 240 minute back up back up back up back up 0.5 KVA 400 800 1600 3200 1 KVA 800 1600 3200 6400 2 KVA 1600 3200 6400 12800 3 KVA 2400 4800 9600 19200 5 KVA 4000 8000 16000 32000 6 KVA 4800 9600 19200 38400 7.5 KVA 6000 12000 24000 48000 10 KVA 8000 16000 32000 64000 15 KVA 12000 24000 48000 96000 20 KVA 16000 32000 64000 128000 30 KVA 24000 48000 96000 192000

(M.A. Ansari ) Incharge PS-II

Page 11: ups system

11 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/PG/4225 Dated: 26.09.2012 16. Testing requirement for UPS: a. Type Tests : Following shall constitute type test and at least one sample shall be type tested for each rating with maximum backup time. Type testing shall be conducted either atan independent govt. lab or at the premises of the manufacturer in presence of an officer from concerned Directorate of Quality Assurance. (i) Visual examination. (ii) Verification of output power and frequency. (iii) Verification of voltage regulation. (iv) Verification of efficiency. (v) Verification of total harmonics distortion. (vi) Verification of overshoot, undershoot limits and over voltage protection. (vii) Test for insulation resistance, leakage current high voltage as per IS:616/86 (reaffirmed in 1991. Insulation resistance should not be less than 100 mega ohms. (viii) Verification of VAH as per Rate Contract. (ix) Environmental tests: Following environmental tests shall be carried out on the highest rating. Tests at SL. No. i to iii above shall be repeated during the last half an hour of each environmental condition. Tests at Sl. No. i to vi shall be repeated after completing the environmental tests sequence of the three conditions and recovery period of 1 to 2 hours. There shall be no deterioration in any of these parameters when compared to the test results obtained before environmental tests (A) Dry Heat Test : shall be carried out in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2004) at 55 degree C for 16 hrs. (B) Damp Heat : shall be carried out at upper Temperature of 40 degree C,two cycles of (12+12 hours)each in accordance with IS:9000 (part 5/sec.2)1981 (reaffirmed 2004). (C) Cold Test : shall be carried out in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2004) at -10 degree C for 4 hrs. b. Acceptance Tests : Tests listed at Sl. No.i to viii shall constitute acceptance test. Acceptance test shall be carried out on all the items offered for inspection. Schedule 5 Line Interactive UPS with AVR for single phase AC 160V to 280V input. Unit : NOS. Specification : As per detailed specification and General Technical requirements. Rated KVA Minimum VAH

UPS27001055 0.5 / 84 UPS27001056 0.5 / 168 UPS27001057 0.5 / 400 UPS27001059 0.65 / 400 UPS27001061 0.8 / 168 UPS27001062 0.8 / 400 UPS27001063 0.8 / 216 UPS27001064 1.0 / 168 UPS27001065 1.0 / 400 UPS27001066 1.0 / 216 UPS27001068 1.5 / 800 UPS27001069 1.5 / 600 UPS27001070 2.0 / 800 UPS27001071 2.0 / 1600

Schedule 6 Line Interactive UPS (CE or UI, certified ) with AVR for single phase AC Unit : Nos. 160V to 280V input. Specification : As per detailed specification and General Technical Requirements. Rated KVA Minimum VAH

UPS27001072 0.5 / 84 UPS27001073 0.5 / 168 UPS27001074 0.5 / 400 UPS27001075 0.65 / 168

(M.A. Ansari )

Incharge PS-II

Page 12: ups system

12 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/PG/4225 Dated: 26.09.2012

UPS27001076 0.65 / 400 UPS27001077 0.65 / 108 UPS27001078 0.8 / 168 UPS27001079 0.8 / 400 UPS27001080 0.8 / 216 UPS27001081 1.0 / 168 UPS27001082 1.0 / 400 UPS27001083 1.0 / 216 UPS27001084 1.0 / 800 UPS27001088 2.0 / 1600

Tenderers to note : 1. Tenderers shall be reqistered for the product in the name of line interactive UPS. They shall be in Possession of TYPE Test Certificates, except Environmental tests, for each rating with highest VAH . However , the Environment Test Certificate only for the highest rating with highest VAH would be acceptable. These test certificates shall be from any Govt. laboratory . For CE or UL Certified Line Interactive UPS, tenderers shall be in possession of CE or UL Certificate for each item quoted and furnish copy thereof with their offer. 2. Tenderers shall declare charging voltage (DC bus voltage) and charging current for each item quoted in their offer. 3. Switching device shall be MOSFET or IGBT and the same shall be declared in the offer by the tenderers. 4. Switching frequency shall be above 50 Hz and shall be declared in the offer. 5. Tenderers hall declare battery AH Capacity , battery voltage , number of batteries of each rating , make and model of batteries offered woth each item of UPS corresponding to the specified minimum VAH rating of battery bank. 6. The Batteries shall be SMF VRLA Type as per JISC and the firms shall submit compliance certificate to the governing specification from OEM to QA officers at the time of inspection. Indentors to note : Typical power consumption of PC is 160 VA , of PC with inkjet printer is 300-400 VA and for PC with laser printer is 700-800 VA . The back up time as available for each item can be calculated on this basis by the indentor before ordering the item. Detailed Specification Schedule 5 Line Interactive UPS with AVR for single phase AC 160V to 280V input. Specification : Line Interactive UPS (CE or UL certified) with AVR and PWM technology for computers suitable for single phase AC input voltage range 160V to 280V, 50 +/-3 Hz and be housed in rugged enclosure made of M.S. Sheet of 1 mm (minimum) thick aesthetically finished , duly pretreated and powder coated or ABS body. Schedule 6 Line Interactive UPS (CE or UL Certified) with AVR for single phase AC 160V to 280V input. Specification : Line Interactive UPS (CE or UL certified) with AVR and PWM technology for computers suitable for single phase AC input voltage range 160V to 280V, 50 +/-3 Hz and single phase AC output voltage 230V +/-9%, 50+/-0.5 Hz in AC mode. It shall be housed in rugged enclosure made of M.S. sheet of 1 mm (minimum) thick aesthetically finished , duly pretreated and powder coated or ABS body. General Technical requirement For TE : A. Suppliers shall furnish complete & satisfactory type test certificate except Environmental test for each rating with highest VAH, however, the, the Environment test certificates only for the highest rating with highest VAH to the Director (QA) concerned at the time of inspection of first lot. TTC shall be from Govt. laboratory. Suppliers, who have already got type test certificates for the existing ratings, would not be required to obtain fresh type test certificates for the same ratings. For CE or UL certified Line Interactive UPS, supplier shall be in possession of CE or UL certificate for each item. B. The firm shall registered for the subject stores in the name of Line Interactive UPS. The type test report for the highest rating of the UPS will be acceptable only for the purpose of grant of registration. C. Specification for Line Interactive UPS with AVR for Computers and general purpose .

(M.A. Ansari ) Incharge PS-II

Page 13: ups system

13 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/PG/4225 Dated: 26.09.2012 1. General (a) UPS shall be free from workmanship defects, sharp edges, nicks,scratches, burs, etc. All fasteners shall be fixed properly. The equipment shall be complete with all parts and all parts shall be functional. (b) Enclosures shall conform to protection requirement of IP2L1 to IS13947 (Part 1)/1993 (reaffirmed 2004). (c) Switching device shall be MOSFET or IGBT and the same shall be declared in the offer by the tenderers. (d) Switching frequency shall be above 50 Hz and shall be declared in the offer. 2. Switching over time from AC mains to UPS mode on power failure should be 10 milliseconds maximum. 3. Input : 160 to 280V, 50 +-3 Hz Single Phase AC. 4. Output : (a) AVR output voltage in AC mode : 230 Volts +/- 9 %, 50 +/- 3Hz. (b) UPS output voltage in battery mode : 230 volts +/-10%, 50 +/-0.5 Hz. at Load power factor of not less than 0.6 lag. 5. Total Harmonics distortion : 40% maximum to be mea sued in DC mode. 6. Efficiency (at rated output voltage and frequency) Inverter efficiency : Minimum 70% 7. Regulation : Total variation of voltage from no load to full shall not exceed 10% and at no point the output voltage should go beyond the permissible band of 230 volts +/-9% 8. Overload : UPS shall withstand 10% overload for at least 10 minutes inmains node. 9. Protections: (a) Input voltage goes outside the range 160 to 280 Volts the system shalls witch over to battery mode. (b) Over voltage, short circuit, and overload at UPS output terminals. (c) Protection of battery terminals falls below 10.5 V for 12 Volts and 21V for 24 Volts battery system. 10. Indicators and meters: (i) Mains mode. (ii) UPS mode. (iii) Battery Low 11. Battery Bank: (a) The batteries shall be of 12 Volts Sealed Lead Acid Valve Regulated Type (VRLA) as per JISC: 8707/1992 or to JISC: 8702 /1998 & the supplier shall submit compliance certificate to the governing specification from OEM to the concerned D(QA) at the time of inspection (b) Suppliers shall declare battery AH Capacity, battery Voltage, number of batteries of each rating, make and model of batteries offered with each item of UPS corresponding to the specified minimum VAH rating of battery bank. (c) In case the batteries are not housed inside UPS cabinet, suitable enclosure/rack to mount these batteries shall also be supplied along with the batteries. 12. Freight charges for dispatch shall be per unit basis subject to the conditions specified in terms & conditions of T/e for various distanceslabs/regions/destinations. D. Testing requirement for UPS 1. Type tests : Following shall constitute the type testing. And shall be carried out at least on one unit of each rating (a) Visual examination (b) Verification of output power and frequency (c) Verification of voltage regulation. (d) Verification of efficiency (e) Verification of total harmonics distortion. (f) Verification over voltage protection. (g) Test for insulation resistance, leakage current and high voltage as per IS : 616/2003 (IEC 60065-2001) Insulation resistance should not be less than 100 mega ohms.

(M.A. Ansari ) Incharge PS-II

Page 14: ups system

14 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/PG/4225 Dated: 26.09.2012 (h) Test for minimum VAH capacity of the battery. (i) Capacity test (C20) and High rate Discharge shall also be carried out at the time of first inspection for each rating, make and model of battery at the firm's premises. 2. Environmental tests : Following environment tests shall be carried out. During the last 1/2 an hour of each environmental test functional tests functional tests, as at SL. No. 1, 2 further after each environmental test the functional performance mentioned at SL. No. (a) To (f) shall be checked after recovery period of 1 hour and test results shall be satisfactory. (a) Burn-inTest: At a temperature of 45 degree C for 48 hours with power on and at full load. (b) Dry Heat Test: At 45 degree C for 16 hrs in accordance with IS: 9000 (Part 3/Sec. 5)/1997). (Reaffirmed 2004) (c) Damp Heat Test: At 40 degree C, RH 95% for two cycles. In accordance with IS:: 9000 (Part 5/sec. 1) 1981 (Reaffirmed 2004) (d) Cold Test: At 0 degree C for 2 hrs in accordance with IS: 9000 (Part 2/Sec. 4)/1997). (Reaffirmed 2004) 3. Acceptance tests: Tests listed at SL. No. (a) To (h) shall constitute acceptance test and shall be carried out on all the items offered for inspection. Capacity test for the battery shall also be carried out as an acceptance test against each lot.

(M.A. Ansari )

Incharge PS-II

Page 15: ups system

15 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/PG/4225 Dated: 26.09.2012

SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)

---------------------------------------NIL ------------------------------------ ------------------------------------------------------------------------------------------------------------------------

(Subas Chandra Bhagat ) I/c Marketing-I

Page 16: ups system

16 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/PG/4225 Dated: 26.09.2012

SCHEDULE – “D”

FORMAT FOR QUATERLY DRAWAL REPORT

Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of

Department Quantity and Value of Orders Received (Rs.)

Quantity and Value of Orders Executed (Rs.)

Balance Quantity and Value to be Supplied (Rs.)

Reasons

Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.

Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges

2. Nil report should also be Submitted.

(Subas Chandra Bhagat ) I/c Marketing-I

Page 17: ups system

17 /59 Chhattisgarh State Industrial Development Corporation Limited (A Government of Chhattisgarh Undertaking) LIC Campus, Pandri Raipur 492 004 (C.G) Phone 91-771-2583789-90, Fax : 91-771-2583794, 4091879 Website: www.csidc.in, Email : [email protected], [email protected]

No./CSIDC/MKD/ PS- II / 12-13/ Raipur, Dated : Registered A/D Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/RS/4226 Dated: 26.09.2012 To,

M/s. RS Power System H1-85, RIICO Industrial Area Mansarovar, Jaipur-302020 Pho. 0141-2396550, 2395860 Fax- 0141-2395860

Sub :- Rate Contract for the supply of Item UPS System (Valid From dated 26.09.2012 to 25.09.2013)

Ref :- (I) This Office Tender Enquiry No. CSIDC/MKD/ PS- II / 71-291/12-13 (II) Your Bid No. 5948 dated 21.07.2012 (III) Your Offer acceptance along with undertaking submitted on dated 20.09.2012

Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2 . The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction .

You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment . SCHEDULES ANNEXED : 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item UPS System

Item UPS System 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 15 pages

Yours faithfully,

(Subas Chandra Bhagat ) I/c Marketing-I

For and on behalf of the purchaser named in CSIDC Form No.2

Page 18: ups system

18 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/RS/4226 Dated: 26.09.2012 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .

2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .

3. The Accountant General Chhattisgarh State, Raipur.

4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC, pre dispatched inspection of stores, also acceptance of store and ensure to endorse the copy of purchase order (Indent) to the CSIDC Ltd., for further approval of authorized pre dispatch Inspection Agency enlisted in the CSIDC panel.

5. All The Collectors ,Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC, pre dispatched inspection of stores, acceptance of store and ensure to endorse the copy of purchase order (Indent) to the CSIDC Ltd., for further approval of authorized pre dispatch Inspection Agency enlisted in the CSIDC panel

6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control

7. (i) The Director Directorate of Public Instruction, Pension bada, Raipur (ii) The Director Directorate of Tribal welfare & Backward Classes ,Pt.R.S.U. Campus Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur

Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. release of supply order, inspection of stores, payment of bill whichever is applicable, as the responsibility rests with the concerned authority .

8. (i) ADG (Q & A) , DGS&D, Jeewan Tara Building 5 Parliament Street New Delhi 110001 (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor, Infront

of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Churchgate Station Road, Second Floor, M.K.

Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-

462011. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.

9. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file of Rate Contract.

10. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.

11. Main file of Item- UPS System

(Subas Chandra Bhagat )

I/c Marketing-I For and on behalf of the purchaser

Named in CSIDC Form No.2

Page 19: ups system

19 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/RS/4226 Dated: 26.09.2012

SCHEDULE “A” Description of Stores, Prices, Duties/Taxes

For the supply of Item- UPS System as per Annexure’A’ enclosed.

1. (a) NAME AND FULL ADDRESS OF :- M/s. RS Power System THE FIRM H1-85, RIICO Industrial Area

Mansarovar, Jaipur-302020

NAME AND FULL ADDRESS OF M/s. RS Power System MANUFACTURER H1-85, RIICO Industrial Area

Mansarovar, Jaipur-302020

(b1) CATEGORY :- General

2. VALIDITY OF RATE CONTRACT :- From 26.09.2012 to 25.09.2013 4. DESCRIPTION OF ITEM- UPS System SPECIFICATION, UNIT RATE AS BELOW

Item Code No. Item Description Class Rate FOR Dest.

ED &VAT/CST Extra As Applicable Rate Per Unit

1 2 3 Schedule1On-Line UPS with isolation transformer suitable for Three Phase AC Inputand Three Phase AC Output,Floor Mounted TypeUnit :NOS.Rating of UPS Indicative Back-Up time

UPS27001002 10 KVA / 60 minutes 164551.00 UPS27001004 15 KVA / 30 minutes 182864.00 UPS27001005 15 KVA / 60 minutes 229269.00 UPS27001006 15 KVA / 120 minutes 339528.00 UPS27001007 20 KVA / 30 minutes 223572.00 UPS27001008 20 KVA / 60 minutes 299996.00 UPS27001009 20 KVA / 120 minutes 458386.00 UPS27001010 30 KVA / 30 minutes 175680.00 UPS27001011 30 KVA / 60 minutes 370625.00 UPS27001012 30 KVA / 120 minutes 631731.00 Schedule-2 On-Line UPS with isolation transformer suitable for Three Phase AC Input and Single Phase AC Output,Floor Mounted Type Unit : NOS. Rating of UPS Indicative Back-Up time

UPS27001013 10 KVA / 30 minutes 104714.00 UPS27001014 10 KVA / 60 minutes 136899.00 UPS27001015 10 KVA / 120 minutes 191296.00 UPS27001016 15 KVA / 30 minutes 145965.00 UPS27001017 15 KVA / 60 minutes 178603.00 UPS27001018 15 KVA / 120 minutes 281958.00 UPS27001019 20 KVA / 30 minutes 161378.00 UPS27001020 20 KVA / 60 minutes 244786.00 UPS27001021 20 KVA / 120 minutes 389845.00 UPS27001022 30 KVA / 30 minutes 222121.00 UPS27001023 30 KVA / 60 minutes 351767.00 UPS27001024 30 KVA / 120 minutes 545784.00 Schedule4On-Line UPS with isolation transformer suitable for single phase AC input & single phase AC output, Floor Mounted TypeUnit :NOSating of UPS Indicative Back-up time

UPS27001043 5.0 KVA / 30 Minutes 55303.00 UPS27001044 5.0 KVA / 60Minutes 70716.00 UPS27001045 5.0 KVA / 120 Minutes 106980.00 UPS27001051 7.5 KVA / 120 Minutes 62733.00

(Subas Chandra Bhagat ) I/c Marketing-I

Page 20: ups system

20 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/RS/4226 Dated: 26.09.2012

Schedule5Line Interactive UPS with AVR for single phase AC 160V to 280V input.Unit :NOS.Specification:As per detailed specification and General Technical Requirements.Rated KVA Minimum VAH

UPS27001055 0.5 / 84 1469.00 UPS27001056 0.5 / 168 2457.00 UPS27001057 0.5 / 400 3826.00 UPS27001059 0.65 / 400 4170.00 UPS27001061 0.8 / 168 3055.00 UPS27001062 0.8 / 400 4597.00 UPS27001063 0.8 / 216 3581.00 UPS27001064 1.0 / 168 3654.00 UPS27001065 1.0 / 400 5553.00 UPS27001066 1.0 / 216 3762.00 UPS27001068 1.5 / 800 8794.00 UPS27001069 1.5 / 600 7797.00 UPS27001070 2.0 / 800 11015.00 UPS27001071 2.0 / 1600 13123.00 Schedule6Line Interactive UPS (CE or UL certified) with AVR for single phase AC160V to 280V input.Unit :NOS.Specification: As per detailed specification and General Technical Requirements.Rated KVA Minimum VAHRated KVA Minimum VAH

UPS27001072 0.5 / 84 1477.00 UPS27001073 0.5 / 168 2468.00 UPS27001074 0.5 / 400 3840.00 UPS27001075 0.65 / 168 2609.00 UPS27001076 0.65 / 400 4176.00 UPS27001077 0.65 / 108 2232.00 UPS27001078 0.8 / 168 3071.00 UPS27001079 0.8 / 400 4612.00 UPS27001080 0.8 / 216 3595.00 UPS27001081 1.0 / 168 3662.00 UPS27001082 1.0 / 400 5565.00 UPS27001083 1.0 / 216 4923.00 UPS27001084 1.0 / 800 7501.00 UPS27001088 2.0 / 1600 14055.00

Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination ( Any where in C.G.State ) 5. EXCISE DUTY : Extra as applicable 6. SALES TAX /VAT/CST : Extra as applicable

Tin No. 08191606089 Address:-

M/s. RS Power System H1-85, RIICO Industrial Area Mansarovar, Jaipur-302020

7. DELIVERY PERIOD : With in 30 to 90 days 8. a. ANNUAL TURN OVER/ : 2007-08 Rs. 12668193569

2008-09 Rs. 127775743.05 2009-10 Rs. 100101691.29

b. MONETARY LIMIT : NM

(Subas Chandra Bhagat ) I/c Marketing-I

Page 21: ups system

21 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/RS/4226 Dated: 26.09.2012 c. INSTALLED CAPACITY : (as per DGS&D Registration Certificate) Description Capacity/Annum

UPS System 7200 Nos.

9. SLAB DISCOUNT (IF ANY) : Nil 10. PRICES : Prices are Firm and Final 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : Manufacturer

FIRM 13. REGISTRATION STATUS : Manufacturer is Registered with DGS&D Jaipur DGS7D/REGN/JAI/S-3751/10/05399 valid upto 10.03.2010 to 09.03.2013 14 BIS LICENSE : NM 15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding

Officers (DDOs). 16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each

consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .

17 INSPECTION AUTHORITY : Accorded by CSIDC Ltd. While receipt of copy of purchase Order(Indent) in Favour of authorized pre dispatched Inspection Agency enlisted in the CSIDC panel prior to submission of application from the Rate Contract Holders.

18 QUALITY ASSURANCE: a)Accorded by CSIDC Ltd. While receipt of copy of purchase

Order (Indent) in Favour of authorized pre dispatched Inspection Agency enlisted in the CSIDC panel prior to submission of application from the Rate Contract Holders.

b)Post-dispatch inspection by the committee constituted by the Direct Demanding Officers /Purchase Department .

OR Post Dispetch Inspection of Stores carried by the Inspection

Agency enlisted in the CSIDC prior to receiving of proposal from the end user/Purchase Department.

19. PLACE WHERE THE STORES At Manufacturer’s Factory at

ARE TO BE OFFERED FOR M/S. RS POWER SYSTEM INSPECTION H1-85, RIICO INDUSTRIAL AREA

MANSAROVAR, JAIPUR-302020

(Subas Chandra Bhagat ) I/c Marketing-I

Page 22: ups system

22 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/RS/4226 Dated: 26.09.2012

20 INSPECTION CHARGES : Inspection charges 0.60%+ Service Tax As applicable to be

paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.

21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause

7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.

22. Special Note 1. Purchasing Departments will ensure pre dispatch inspection of Materials. 2. Purchasing Departments will be responsible for ensuring the Quality of accepted materials. 3. Purchasing Departments will ensure sending copy of every order to this office.

(Subas Chandra Bhagat ) I/c Marketing-I

Page 23: ups system

23 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/RS/4226 Dated: 26.09.2012

Annexure - “A” Technical Particulars For On-Line UPS For IT Applications Schedule 1 On-Line UPS with isolation transformer suitable for Three Phase AC Input and Three Phase AC Output,Floor Mounted Type Unit : NOS. Rating of UPS Indicative Back-Up time

UPS27001002 10 KVA / 60 minutes UPS27001004 15 KVA / 30 minutes UPS27001005 15 KVA / 60 minutes UPS27001006 15 KVA / 120 minutes UPS27001007 20 KVA / 30 minutes UPS27001008 20 KVA / 60 minutes UPS27001009 20 KVA / 120 minutes UPS27001010 30 KVA / 30 minutes UPS27001011 30 KVA / 60 minutes UPS27001012 30 KVA / 120 minutes

Schedule 2 On-Line UPS with isolation transformer suitable for Three Phase AC Input and Single Phase AC Output,Floor Mounted Type Unit : NOS. Rating of UPS Indicative Back-Up time

UPS27001013 10 KVA / 30 minutes UPS27001014 10 KVA / 60 minutes UPS27001015 10 KVA / 120 minutes UPS27001016 15 KVA / 30 minutes UPS27001017 15 KVA / 60 minutes UPS27001018 15 KVA / 120 minutes UPS27001019 20 KVA / 30 minutes UPS27001020 20 KVA / 60 minutes UPS27001021 20 KVA / 120 minutes UPS27001022 30 KVA / 30 minutes UPS27001023 30 KVA / 60 minutes UPS27001024 30 KVA / 120 minutes

Schedule 4 On-Line UPS with isolation transformer suitable for single phase AC input & single phase AC output, Floor Mounted Type Unit : NOS. Rating of UPS Indicative Back-up time

UPS27001043 5.0 KVA / 30 Minutes UPS27001044 5.0 KVA / 60Minutes UPS27001045 5.0 KVA / 120 Minutes UPS27001051 7.5 KVA / 120 Minutes

(M.A. Ansari ) Incharge PS-II

Page 24: ups system

24 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/RS/4226 Dated: 26.09.2012 Questionnaire Schedule On-Line UPS with isolation transformer suitable for Three Phase AC Input and Single Phase AC Output,Floor Mounted Type 1 Online UPS for IT application 1.1 Charging voltage (DC Bus Voltage) 1.2 Charging current 1.3 Switching device (MOSFET/IGBT) 1.4 Switching frequency (should be more than 10kHz) 1.5 Battery AH capacity 1.6 Battery voltage 1.7 No of batteries 1.8 Make/Model of batteries Questionnaire Schedule On-Line UPS with isolation transformer suitable for single phase AC input & single phase AC output, Floor Mounted Type 1. Online UPS for IT application 1.1 Charging voltage (DC Bus voltage) 1.2 Charging current 1.3 Switching device (MOSFET /IGBT) 1.4 Switching frequency( (should be more than 10kHz) 1.5 Battery AH capacity 1.6 Battery voltage 1.7 No of batteries 1.8 Make/Model of batteries Questionnaire Schedule On-Line UPS with isolation transformer suitable for Three Phase AC Input and Three Phase AC Output,Floor Mounted Type 1 Online UPS for IT application 1.1 Charging voltage (DC Bus Voltage) 1.2 Charging current 1.3 Switching device (MOSFET/IGBT) 1.4 Switching frequency (should be more than 10kHz) 1.5 Battery AH capacity 1.6 Battery voltage 1.7 No of batteries 1.8 Make/Model of batteries General Technical requirement For TE : 1. General a. UPS shall be free from workmanship defects, sharp edges, nicks, scratches, burs, etc. All fasteners shall be fixed properly. The equipment shall be complete with all parts and all parts shall be functional. b. Enclosures shall conform to protection requirement of IP2L1 to IS13947 (part 1)/1993 (reaffirmed 1998). c. By-pass facility shall be provided for maintenance of UPS. d. UPS shall supply output power and charging current at the same time. e. Switching device shall be MOSFET or IGBT and the same shall be confirm in the offer. f. Switching frequency shall be above 10 KHz and shall be declared in the offer. g. KW rating of the UPS shall be 0.70 times the KVA rating. 2. Input (as applicable) a. 160V-260V, 50 +/-3% Hz single phase AC or b. 300V-450V, 50 +/-3%Hz three phase AC

(M.A. Ansari )

Incharge PS-II

Page 25: ups system

25 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/RS/4226 Dated: 26.09.2012 3. Output (as applicable) a. 230V +/-1% (with alternative setting for 220V +/-1%) 50 +/-0.5Hz, single phase. b. 400V +/-1% (with alternative setting for 380V +/-1%) 50 +/-0.5Hz three phase. Voltage regulation from no load to full load shall be within +/-1% in both the cases. UPS shall also have facility for operation in synchronous mode in which output frequency shall be same as that of mains frequency. 4. Total harmonics distortion at output : 2% maximum for UPS up to 5KVA and 3% maximum for UPS above 5 KVA on resistive load. If total input harmonics are less than or equal to 10%. 5. Efficiency (at rated output voltage and frequency) a. Overall efficiency (minimum) : 90% 6. UPS power factor at rated load : better than 0.9 lagging. 7. Over load : UPS shall withstand 20% overload for 10 minutes and 50% over load for one minute. 8. Protections : Following protection shall be provided in UPS: a. Over voltage, short circuit, and overload at UPS output terminal. b. Under voltage at battery terminal. c. Over shoot and under shoot shall not be greater than 4% of rated voltage for duration of 40m sec. (maximum) 9. Indicators and meters a. Following indicators shall be provided:- (i) Mains presence. (ii) Battery charging and discharging (iii) Output overload (iv) Low battery voltage. b. Digital meter shall be provided for monitoring the following parameters in UPS(not applicable for rack mounting): (i) Input AC voltage. (ii) Output AC Voltage, current and frequency (iii) Battery voltage and current. 10. Battery bank: a. UPS shall be supplied with SMF VRLA battery only. b. Tenderers shall declare battery AH capacity, battery voltage, number of batteries of each rating, make and model of batteries offered with each item of UPS. c. Batteries for UPS shall be of the following makes:- Exide, Panasonic, Amar Raja, Global, Rocket ,Base, RITAR make & DGS&D registered batteries or any other make duly type tested to JIS C 8702 from DGS&D approved lab. d. The UPS shall be complete with Trolley for battery bank and the firms shall also connect the batteries with UPS and commission the same. e. Minimum VAH rating of battery bank for different duration of back up time shall be as detailed below: UPS rating Min.VAH Min. VAH Min VAH Min. VAH in KVA 30 minute 60 minute 120 minute 240 minute back up back up back up back up 0.5 KVA 400 800 1600 3200 1 KVA 800 1600 3200 6400 2 KVA 1600 3200 6400 12800 3 KVA 2400 4800 9600 19200 5 KVA 4000 8000 16000 32000 6 KVA 4800 9600 19200 38400 7.5 KVA 6000 12000 24000 48000 10 KVA 8000 16000 32000 64000 15 KVA 12000 24000 48000 96000 20 KVA 16000 32000 64000 128000 30 KVA 24000 48000 96000 192000

(M.A. Ansari ) Incharge PS-II

Page 26: ups system

26 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/RS/4226 Dated: 26.09.2012 16. Testing requirement for UPS: a. Type Tests : Following shall constitute type test and at least one sample shall be type tested for each rating with maximum backup time. Type testing shall be conducted either atan independent govt. lab or at the premises of the manufacturer in presence of an officer from concerned Directorate of Quality Assurance. (i) Visual examination. (ii) Verification of output power and frequency. (iii) Verification of voltage regulation. (iv) Verification of efficiency. (v) Verification of total harmonics distortion. (vi) Verification of overshoot, undershoot limits and over voltage protection. (vii) Test for insulation resistance, leakage current high voltage as per IS:616/86 (reaffirmed in 1991. Insulation resistance should not be less than 100 mega ohms. (viii) Verification of VAH as per Rate Contract. (ix) Environmental tests: Following environmental tests shall be carried out on the highest rating. Tests at SL. No. i to iii above shall be repeated during the last half an hour of each environmental condition. Tests at Sl. No. i to vi shall be repeated after completing the environmental tests sequence of the three conditions and recovery period of 1 to 2 hours. There shall be no deterioration in any of these parameters when compared to the test results obtained before environmental tests (A) Dry Heat Test : shall be carried out in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2004) at 55 degree C for 16 hrs. (B) Damp Heat : shall be carried out at upper Temperature of 40 degree C,two cycles of (12+12 hours)each in accordance with IS:9000 (part 5/sec.2)1981 (reaffirmed 2004). (C) Cold Test : shall be carried out in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2004) at -10 degree C for 4 hrs. b. Acceptance Tests : Tests listed at Sl. No.i to viii shall constitute acceptance test. Acceptance test shall be carried out on all the items offered for inspection. Schedule 5 Line Interactive UPS with AVR for single phase AC 160V to 280V input. Unit : NOS. Specification : As per detailed specification and General Technical requirements. Rated KVA Minimum VAH

UPS27001055 0.5 / 84 UPS27001056 0.5 / 168 UPS27001057 0.5 / 400 UPS27001059 0.65 / 400 UPS27001061 0.8 / 168 UPS27001062 0.8 / 400 UPS27001063 0.8 / 216 UPS27001064 1.0 / 168 UPS27001065 1.0 / 400 UPS27001066 1.0 / 216 UPS27001068 1.5 / 800 UPS27001069 1.5 / 600 UPS27001070 2.0 / 800 UPS27001071 2.0 / 1600

Schedule 6 Line Interactive UPS (CE or UI, certified ) with AVR for single phase AC Unit : Nos. 160V to 280V input. Specification : As per detailed specification and General Technical Requirements. Rated KVA Minimum VAH

UPS27001072 0.5 / 84 UPS27001073 0.5 / 168 UPS27001074 0.5 / 400 UPS27001075 0.65 / 168

(M.A. Ansari )

Incharge PS-II

Page 27: ups system

27 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/RS/4226 Dated: 26.09.2012

UPS27001076 0.65 / 400 UPS27001077 0.65 / 108 UPS27001078 0.8 / 168 UPS27001079 0.8 / 400 UPS27001080 0.8 / 216 UPS27001081 1.0 / 168 UPS27001082 1.0 / 400 UPS27001083 1.0 / 216 UPS27001084 1.0 / 800 UPS27001088 2.0 / 1600

Tenderers to note : 1. Tenderers shall be reqistered for the product in the name of line interactive UPS. They shall be in Possession of TYPE Test Certificates, except Environmental tests, for each rating with highest VAH . However , the Environment Test Certificate only for the highest rating with highest VAH would be acceptable. These test certificates shall be from any Govt. laboratory . For CE or UL Certified Line Interactive UPS, tenderers shall be in possession of CE or UL Certificate for each item quoted and furnish copy thereof with their offer. 2. Tenderers shall declare charging voltage (DC bus voltage) and charging current for each item quoted in their offer. 3. Switching device shall be MOSFET or IGBT and the same shall be declared in the offer by the tenderers. 4. Switching frequency shall be above 50 Hz and shall be declared in the offer. 5. Tenderers hall declare battery AH Capacity , battery voltage , number of batteries of each rating , make and model of batteries offered woth each item of UPS corresponding to the specified minimum VAH rating of battery bank. 6. The Batteries shall be SMF VRLA Type as per JISC and the firms shall submit compliance certificate to the governing specification from OEM to QA officers at the time of inspection. Indentors to note : Typical power consumption of PC is 160 VA , of PC with inkjet printer is 300-400 VA and for PC with laser printer is 700-800 VA . The back up time as available for each item can be calculated on this basis by the indentor before ordering the item. Detailed Specification Schedule 5 Line Interactive UPS with AVR for single phase AC 160V to 280V input. Specification : Line Interactive UPS (CE or UL certified) with AVR and PWM technology for computers suitable for single phase AC input voltage range 160V to 280V, 50 +/-3 Hz and be housed in rugged enclosure made of M.S. Sheet of 1 mm (minimum) thick aesthetically finished , duly pretreated and powder coated or ABS body. Schedule 6 Line Interactive UPS (CE or UL Certified) with AVR for single phase AC 160V to 280V input. Specification : Line Interactive UPS (CE or UL certified) with AVR and PWM technology for computers suitable for single phase AC input voltage range 160V to 280V, 50 +/-3 Hz and single phase AC output voltage 230V +/-9%, 50+/-0.5 Hz in AC mode. It shall be housed in rugged enclosure made of M.S. sheet of 1 mm (minimum) thick aesthetically finished , duly pretreated and powder coated or ABS body. General Technical requirement For TE : A. Suppliers shall furnish complete & satisfactory type test certificate except Environmental test for each rating with highest VAH, however, the, the Environment test certificates only for the highest rating with highest VAH to the Director (QA) concerned at the time of inspection of first lot. TTC shall be from Govt. laboratory. Suppliers, who have already got type test certificates for the existing ratings, would not be required to obtain fresh type test certificates for the same ratings. For CE or UL certified Line Interactive UPS, supplier shall be in possession of CE or UL certificate for each item. B. The firm shall registered for the subject stores in the name of Line Interactive UPS. The type test report for the highest rating of the UPS will be acceptable only for the purpose of grant of registration. C. Specification for Line Interactive UPS with AVR for Computers and general purpose .

(M.A. Ansari ) Incharge PS-II

Page 28: ups system

28 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/RS/4226 Dated: 26.09.2012 1. General (a) UPS shall be free from workmanship defects, sharp edges, nicks,scratches, burs, etc. All fasteners shall be fixed properly. The equipment shall be complete with all parts and all parts shall be functional. (b) Enclosures shall conform to protection requirement of IP2L1 to IS13947 (Part 1)/1993 (reaffirmed 2004). (c) Switching device shall be MOSFET or IGBT and the same shall be declared in the offer by the tenderers. (d) Switching frequency shall be above 50 Hz and shall be declared in the offer. 2. Switching over time from AC mains to UPS mode on power failure should be 10 milliseconds maximum. 3. Input : 160 to 280V, 50 +-3 Hz Single Phase AC. 4. Output : (a) AVR output voltage in AC mode : 230 Volts +/- 9 %, 50 +/- 3Hz. (b) UPS output voltage in battery mode : 230 volts +/-10%, 50 +/-0.5 Hz. at Load power factor of not less than 0.6 lag. 5. Total Harmonics distortion : 40% maximum to be mea sued in DC mode. 6. Efficiency (at rated output voltage and frequency) Inverter efficiency : Minimum 70% 7. Regulation : Total variation of voltage from no load to full shall not exceed 10% and at no point the output voltage should go beyond the permissible band of 230 volts +/-9% 8. Overload : UPS shall withstand 10% overload for at least 10 minutes inmains node. 9. Protections: (a) Input voltage goes outside the range 160 to 280 Volts the system shalls witch over to battery mode. (b) Over voltage, short circuit, and overload at UPS output terminals. (c) Protection of battery terminals falls below 10.5 V for 12 Volts and 21V for 24 Volts battery system. 10. Indicators and meters: (i) Mains mode. (ii) UPS mode. (iii) Battery Low 11. Battery Bank: (a) The batteries shall be of 12 Volts Sealed Lead Acid Valve Regulated Type (VRLA) as per JISC: 8707/1992 or to JISC: 8702 /1998 & the supplier shall submit compliance certificate to the governing specification from OEM to the concerned D(QA) at the time of inspection (b) Suppliers shall declare battery AH Capacity, battery Voltage, number of batteries of each rating, make and model of batteries offered with each item of UPS corresponding to the specified minimum VAH rating of battery bank. (c) In case the batteries are not housed inside UPS cabinet, suitable enclosure/rack to mount these batteries shall also be supplied along with the batteries. 12. Freight charges for dispatch shall be per unit basis subject to the conditions specified in terms & conditions of T/e for various distanceslabs/regions/destinations. D. Testing requirement for UPS 1. Type tests : Following shall constitute the type testing. And shall be carried out at least on one unit of each rating (a) Visual examination (b) Verification of output power and frequency (c) Verification of voltage regulation. (d) Verification of efficiency (e) Verification of total harmonics distortion. (f) Verification over voltage protection. (g) Test for insulation resistance, leakage current and high voltage as per IS : 616/2003 (IEC 60065-2001) Insulation resistance should not be less than 100 mega ohms.

(M.A. Ansari ) Incharge PS-II

Page 29: ups system

29 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/RS/4226 Dated: 26.09.2012 (h) Test for minimum VAH capacity of the battery. (i) Capacity test (C20) and High rate Discharge shall also be carried out at the time of first inspection for each rating, make and model of battery at the firm's premises. 2. Environmental tests : Following environment tests shall be carried out. During the last 1/2 an hour of each environmental test functional tests functional tests, as at SL. No. 1, 2 further after each environmental test the functional performance mentioned at SL. No. (a) To (f) shall be checked after recovery period of 1 hour and test results shall be satisfactory. (a) Burn-inTest: At a temperature of 45 degree C for 48 hours with power on and at full load. (b) Dry Heat Test: At 45 degree C for 16 hrs in accordance with IS: 9000 (Part 3/Sec. 5)/1997). (Reaffirmed 2004) (c) Damp Heat Test: At 40 degree C, RH 95% for two cycles. In accordance with IS:: 9000 (Part 5/sec. 1) 1981 (Reaffirmed 2004) (d) Cold Test: At 0 degree C for 2 hrs in accordance with IS: 9000 (Part 2/Sec. 4)/1997). (Reaffirmed 2004) 3. Acceptance tests: Tests listed at SL. No. (a) To (h) shall constitute acceptance test and shall be carried out on all the items offered for inspection. Capacity test for the battery shall also be carried out as an acceptance test against each lot.

(M.A. Ansari )

Incharge PS-II

Page 30: ups system

30 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/RS/4226 Dated: 26.09.2012

SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)

---------------------------------------NIL ------------------------------------ ------------------------------------------------------------------------------------------------------------------------

(Subas Chandra Bhagat ) I/c Marketing-I

Page 31: ups system

31 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/RS/4226 Dated: 26.09.2012

SCHEDULE – “D”

FORMAT FOR QUATERLY DRAWAL REPORT

Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of

Department Quantity and Value of Orders Received (Rs.)

Quantity and Value of Orders Executed (Rs.)

Balance Quantity and Value to be Supplied (Rs.)

Reasons

Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.

Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges

2. Nil report should also be Submitted.

(Subas Chandra Bhagat ) I/c Marketing-I

Page 32: ups system

32 /59 Chhattisgarh State Industrial Development Corporation Limited (A Government of Chhattisgarh Undertaking) LIC Campus, Pandri Raipur 492 004 (C.G) Phone 91-771-2583789-90, Fax : 91-771-2583794, 4091879 Website: www.csidc.in, Email : [email protected], [email protected]

No./CSIDC/MKD/ PS- II / 12-13/ Raipur, Dated : Registered A/D Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/CN/4227 Dated: 26.09.2012 To,

M/s. Cyber Net Shop No-177 & 178 , Sector -6 "E" Market, Bhilai Distt-Durg (C.G.) Mob- 9826161015

Sub :- Rate Contract for the supply of Item UPS System (Valid From dated 26.09.2012 to 25.09.2013)

Ref :- (I) This Office Tender Enquiry No. CSIDC/MKD/ PS- II / 71-291/12-13 (II) Your Bid No. 5950 dated 17.07.2012 (III) Your Offer acceptance along with undertaking submitted on dated 20.09.2012

Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2 . The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction .

You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment . SCHEDULES ANNEXED : 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item UPS System

Item UPS System 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 13 pages

Yours faithfully,

(Subas Chandra Bhagat ) I/c Marketing-I

For and on behalf of the purchaser named in CSIDC Form No.2

Page 33: ups system

33 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/CN/4227 Dated: 26.09.2012 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .

2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .

3. The Accountant General Chhattisgarh State, Raipur.

4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC, pre dispatched inspection of stores, also acceptance of store and ensure to endorse the copy of purchase order (Indent) to the CSIDC Ltd., for further approval of authorized pre dispatch Inspection Agency enlisted in the CSIDC panel.

5. All The Collectors ,Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC, pre dispatched inspection of stores, acceptance of store and ensure to endorse the copy of purchase order (Indent) to the CSIDC Ltd., for further approval of authorized pre dispatch Inspection Agency enlisted in the CSIDC panel

6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control

7. (i) The Director Directorate of Public Instruction, Pension bada, Raipur (ii) The Director Directorate of Tribal welfare & Backward Classes ,Pt.R.S.U. Campus Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .

Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. release of supply order, inspection of stores, payment of bill whichever is applicable, as the responsibility rests with the concerned authority .

8. (i) ADG (Q & A) , DGS&D, Jeewan Tara Building 5 Parliament Street New Delhi 110001 (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor, Infront

of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Churchgate Station Road, Second Floor, M.K.

Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-

462011. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.

9. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file of Rate Contract.

10. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.

11. Main file of Item- UPS System

(Subas Chandra Bhagat )

I/c Marketing-I For and on behalf of the purchaser

Named in CSIDC Form No.2

Page 34: ups system

34 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/CN/4227 Dated: 26.09.2012

SCHEDULE “A” Description of Stores, Prices, Duties/Taxes

For the supply of Item- UPS System as per Annexure’A’ enclosed.

1. (a) NAME AND FULL ADDRESS OF :- M/s. Cyber Net THE FIRM Shop No-177 & 178 , Sector -6 "E" Market,

Bhilai Distt-Durg (C.G.)

NAME AND FULL ADDRESS OF M/s. Samtek Electronics MANUFACTURER Addr.256 A Street No.4 Pandev Nagar

Delhi-110091 Mob-09826161078

(b1) CATEGORY :- General

2. VALIDITY OF RATE CONTRACT :- From 26.09.2012 to 25.09.2013 5. DESCRIPTION OF ITEM- UPS System SPECIFICATION, UNIT RATE AS BELOW

Item Code No. Item Description Class Rate FOR Dest.

VAT/CST Extra As Applicable Rate Per Unit

1 2 3 Schedule1On-Line UPS with isolation transformer suitable for Three Phase AC Inputand Three Phase AC Output,Floor Mounted TypeUnit :NOS.Rating of UPS Indicative Back-Up time

UPS27001002 10 KVA / 60 minutes 164551.00 UPS27001004 15 KVA / 30 minutes 182864.00 UPS27001005 15 KVA / 60 minutes 229269.00 UPS27001006 15 KVA / 120 minutes 339528.00 UPS27001007 20 KVA / 30 minutes 223572.00 UPS27001008 20 KVA / 60 minutes 299996.00 UPS27001009 20 KVA / 120 minutes 458386.00 UPS27001010 30 KVA / 30 minutes 175680.00 UPS27001011 30 KVA / 60 minutes 370625.00 UPS27001012 30 KVA / 120 minutes 631731.00 Schedule-2 On-Line UPS with isolation transformer suitable for Three Phase AC Input and Single Phase AC Output,Floor Mounted Type Unit : NOS. Rating of UPS Indicative Back-Up time

UPS27001013 10 KVA / 30 minutes 104714.00 UPS27001014 10 KVA / 60 minutes 136899.00 UPS27001015 10 KVA / 120 minutes 191296.00 UPS27001016 15 KVA / 30 minutes 145965.00 UPS27001017 15 KVA / 60 minutes 178603.00 UPS27001018 15 KVA / 120 minutes 281958.00 UPS27001019 20 KVA / 30 minutes 161378.00 UPS27001020 20 KVA / 60 minutes 244786.00 UPS27001021 20 KVA / 120 minutes 389845.00 UPS27001022 30 KVA / 30 minutes 222121.00 UPS27001023 30 KVA / 60 minutes 351767.00 UPS27001024 30 KVA / 120 minutes 545784.00 Schedule4On-Line UPS with isolation transformer suitable for single phase AC input & single phase AC output, Floor Mounted TypeUnit :NOSating of UPS Indicative Back-up time

UPS27001043 5.0 KVA / 30 Minutes 55303.00 UPS27001044 5.0 KVA / 60Minutes 70716.00 UPS27001045 5.0 KVA / 120 Minutes 106980.00

(Subas Chandra Bhagat ) I/c Marketing-I

Page 35: ups system

35 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/CN/4227 Dated: 26.09.2012

Schedule5Line Interactive UPS with AVR for single phase AC 160V to 280V input.Unit :NOS.Specification:As per detailed specification and General Technical Requirements.Rated KVA Minimum VAH

UPS27001055 0.5 / 84 1469.00 UPS27001056 0.5 / 168 2457.00 UPS27001057 0.5 / 400 3826.00 UPS27001059 0.65 / 400 4170.00 UPS27001061 0.8 / 168 3055.00 UPS27001062 0.8 / 400 4597.00 UPS27001063 0.8 / 216 3581.00 UPS27001064 1.0 / 168 3654.00 UPS27001065 1.0 / 400 5553.00 UPS27001066 1.0 / 216 3762.00 UPS27001068 1.5 / 800 8794.00 UPS27001069 1.5 / 600 7797.00 UPS27001070 2.0 / 800 11015.00 UPS27001071 2.0 / 1600 13123.00

Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination ( Any where in C.G.State ) 5. EXCISE DUTY : Not applicable 6. SALES TAX /VAT/CST : Extra as applicable

Tin No. 22683201481 Address:-

M/s. Cyber Net Shop No-177 & 178 , Sector -6 "E" Market, Bhilai Distt-Durg (C.G.)

7. DELIVERY PERIOD : With in 30 to 90 days 8. a. ANNUAL TURN OVER/ : NM

b. MONETARY LIMIT : NM c. INSTALLED CAPACITY : (as per DGS&D Registration Certificate) Description Capacity/Annum

UPS System 24000 Nos

9. SLAB DISCOUNT (IF ANY) : Nil 10. PRICES : Prices are Firm and Final 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : Manufacturer

FIRM 13. REGISTRATION STATUS : Manufacturer is Registered with DGS&D New Delhi DGS7D/REGN/Del/S-3805/10/05484/10 valid upto 10.08.2010 to 08.04.2013 14 BIS LICENSE : NM

(Subas Chandra Bhagat ) I/c Marketing-I

Page 36: ups system

36 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/CN/4227 Dated: 26.09.2012 15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding

Officers (DDOs). 16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each

consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .

17 INSPECTION AUTHORITY : Accorded by CSIDC Ltd. While receipt of copy of purchase Order(Indent) in Favour of authorized pre dispatched Inspection Agency enlisted in the CSIDC panel prior to submission of application from the Rate Contract Holders.

18 QUALITY ASSURANCE: a)Accorded by CSIDC Ltd. While receipt of copy of purchase

Order (Indent) in Favour of authorized pre dispatched Inspection Agency enlisted in the CSIDC panel prior to submission of application from the Rate Contract Holders.

b)Post-dispatch inspection by the committee constituted by the Direct Demanding Officers /Purchase Department .

OR Post Dispetch Inspection of Stores carried by the Inspection

Agency enlisted in the CSIDC prior to receiving of proposal from the end user/Purchase Department.

19. PLACE WHERE THE STORES At Manufacturer’s Factory at

ARE TO BE OFFERED FOR M/s. Samtek Electronics INSPECTION Addr.256 A Street No.4 Pandev Nagar

Delhi-110091 Mob-09826161078

20 INSPECTION CHARGES : Inspection charges 0.60%+ Service Tax As applicable to be paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.

21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause

7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.

22. Special Note 1. Purchasing Departments will ensure pre dispatch inspection of Materials. 2. Purchasing Departments will be responsible for ensuring the Quality of accepted materials. 3. Purchasing Departments will ensure sending copy of every order to this office.

(Subas Chandra Bhagat ) I/c Marketing-I

Page 37: ups system

37 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/CN/4227 Dated: 26.09.2012

Annexure - “A” Technical Particulars For On-Line UPS For IT Applications Schedule 1 On-Line UPS with isolation transformer suitable for Three Phase AC Input and Three Phase AC Output,Floor Mounted Type Unit : NOS. Rating of UPS Indicative Back-Up time

UPS27001002 10 KVA / 60 minutes UPS27001004 15 KVA / 30 minutes UPS27001005 15 KVA / 60 minutes UPS27001006 15 KVA / 120 minutes UPS27001007 20 KVA / 30 minutes UPS27001008 20 KVA / 60 minutes UPS27001009 20 KVA / 120 minutes UPS27001010 30 KVA / 30 minutes UPS27001011 30 KVA / 60 minutes UPS27001012 30 KVA / 120 minutes

Schedule 2 On-Line UPS with isolation transformer suitable for Three Phase AC Input and Single Phase AC Output,Floor Mounted Type Unit : NOS. Rating of UPS Indicative Back-Up time

UPS27001013 10 KVA / 30 minutes UPS27001014 10 KVA / 60 minutes UPS27001015 10 KVA / 120 minutes UPS27001016 15 KVA / 30 minutes UPS27001017 15 KVA / 60 minutes UPS27001018 15 KVA / 120 minutes UPS27001019 20 KVA / 30 minutes UPS27001020 20 KVA / 60 minutes UPS27001021 20 KVA / 120 minutes UPS27001022 30 KVA / 30 minutes UPS27001023 30 KVA / 60 minutes UPS27001024 30 KVA / 120 minutes

Schedule 4 On-Line UPS with isolation transformer suitable for single phase AC input & single phase AC output, Floor Mounted Type Unit : NOS. Rating of UPS Indicative Back-up time

UPS27001043 5.0 KVA / 30 Minutes UPS27001044 5.0 KVA / 60Minutes UPS27001045 5.0 KVA / 120 Minutes UPS27001051 7.5 KVA / 120 Minutes

(M.A. Ansari ) Incharge PS-II

Page 38: ups system

38 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/CN/4227 Dated: 26.09.2012 Questionnaire Schedule On-Line UPS with isolation transformer suitable for Three Phase AC Input and Single Phase AC Output,Floor Mounted Type 1 Online UPS for IT application 1.1 Charging voltage (DC Bus Voltage) 1.2 Charging current 1.3 Switching device (MOSFET/IGBT) 1.4 Switching frequency (should be more than 10kHz) 1.5 Battery AH capacity 1.6 Battery voltage 1.7 No of batteries 1.8 Make/Model of batteries Questionnaire Schedule On-Line UPS with isolation transformer suitable for single phase AC input & single phase AC output, Floor Mounted Type 1. Online UPS for IT application 1.1 Charging voltage (DC Bus voltage) 1.2 Charging current 1.3 Switching device (MOSFET /IGBT) 1.4 Switching frequency( (should be more than 10kHz) 1.5 Battery AH capacity 1.6 Battery voltage 1.7 No of batteries 1.8 Make/Model of batteries Questionnaire Schedule On-Line UPS with isolation transformer suitable for Three Phase AC Input and Three Phase AC Output,Floor Mounted Type 1 Online UPS for IT application 1.1 Charging voltage (DC Bus Voltage) 1.2 Charging current 1.3 Switching device (MOSFET/IGBT) 1.4 Switching frequency (should be more than 10kHz) 1.5 Battery AH capacity 1.6 Battery voltage 1.7 No of batteries 1.8 Make/Model of batteries General Technical requirement For TE : 1. General a. UPS shall be free from workmanship defects, sharp edges, nicks, scratches, burs, etc. All fasteners shall be fixed properly. The equipment shall be complete with all parts and all parts shall be functional. b. Enclosures shall conform to protection requirement of IP2L1 to IS13947 (part 1)/1993 (reaffirmed 1998). c. By-pass facility shall be provided for maintenance of UPS. d. UPS shall supply output power and charging current at the same time. e. Switching device shall be MOSFET or IGBT and the same shall be confirm in the offer. f. Switching frequency shall be above 10 KHz and shall be declared in the offer. g. KW rating of the UPS shall be 0.70 times the KVA rating. 2. Input (as applicable) a. 160V-260V, 50 +/-3% Hz single phase AC or b. 300V-450V, 50 +/-3%Hz three phase AC

(M.A. Ansari )

Incharge PS-II

Page 39: ups system

39 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/CN/4227 Dated: 26.09.2012 3. Output (as applicable) a. 230V +/-1% (with alternative setting for 220V +/-1%) 50 +/-0.5Hz, single phase. b. 400V +/-1% (with alternative setting for 380V +/-1%) 50 +/-0.5Hz three phase. Voltage regulation from no load to full load shall be within +/-1% in both the cases. UPS shall also have facility for operation in synchronous mode in which output frequency shall be same as that of mains frequency. 4. Total harmonics distortion at output : 2% maximum for UPS up to 5KVA and 3% maximum for UPS above 5 KVA on resistive load. If total input harmonics are less than or equal to 10%. 5. Efficiency (at rated output voltage and frequency) a. Overall efficiency (minimum) : 90% 6. UPS power factor at rated load : better than 0.9 lagging. 7. Over load : UPS shall withstand 20% overload for 10 minutes and 50% over load for one minute. 8. Protections : Following protection shall be provided in UPS: a. Over voltage, short circuit, and overload at UPS output terminal. b. Under voltage at battery terminal. c. Over shoot and under shoot shall not be greater than 4% of rated voltage for duration of 40m sec. (maximum) 9. Indicators and meters a. Following indicators shall be provided:- (i) Mains presence. (ii) Battery charging and discharging (iii) Output overload (iv) Low battery voltage. b. Digital meter shall be provided for monitoring the following parameters in UPS(not applicable for rack mounting): (i) Input AC voltage. (ii) Output AC Voltage, current and frequency (iii) Battery voltage and current. 10. Battery bank: a. UPS shall be supplied with SMF VRLA battery only. b. Tenderers shall declare battery AH capacity, battery voltage, number of batteries of each rating, make and model of batteries offered with each item of UPS. c. Batteries for UPS shall be of the following makes:- Exide, Panasonic, Amar Raja, Global, Rocket ,Base, RITAR make & DGS&D registered batteries or any other make duly type tested to JIS C 8702 from DGS&D approved lab. d. The UPS shall be complete with Trolley for battery bank and the firms shall also connect the batteries with UPS and commission the same. e. Minimum VAH rating of battery bank for different duration of back up time shall be as detailed below: UPS rating Min.VAH Min. VAH Min VAH Min. VAH in KVA 30 minute 60 minute 120 minute 240 minute back up back up back up back up 0.5 KVA 400 800 1600 3200 1 KVA 800 1600 3200 6400 2 KVA 1600 3200 6400 12800 3 KVA 2400 4800 9600 19200 5 KVA 4000 8000 16000 32000 6 KVA 4800 9600 19200 38400 7.5 KVA 6000 12000 24000 48000 10 KVA 8000 16000 32000 64000 15 KVA 12000 24000 48000 96000 20 KVA 16000 32000 64000 128000 30 KVA 24000 48000 96000 192000

(M.A. Ansari ) Incharge PS-II

Page 40: ups system

40 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/CN/4227 Dated: 26.09.2012 16. Testing requirement for UPS: a. Type Tests : Following shall constitute type test and at least one sample shall be type tested for each rating with maximum backup time. Type testing shall be conducted either atan independent govt. lab or at the premises of the manufacturer in presence of an officer from concerned Directorate of Quality Assurance. (i) Visual examination. (ii) Verification of output power and frequency. (iii) Verification of voltage regulation. (iv) Verification of efficiency. (v) Verification of total harmonics distortion. (vi) Verification of overshoot, undershoot limits and over voltage protection. (vii) Test for insulation resistance, leakage current high voltage as per IS:616/86 (reaffirmed in 1991. Insulation resistance should not be less than 100 mega ohms. (viii) Verification of VAH as per Rate Contract. (ix) Environmental tests: Following environmental tests shall be carried out on the highest rating. Tests at SL. No. i to iii above shall be repeated during the last half an hour of each environmental condition. Tests at Sl. No. i to vi shall be repeated after completing the environmental tests sequence of the three conditions and recovery period of 1 to 2 hours. There shall be no deterioration in any of these parameters when compared to the test results obtained before environmental tests (A) Dry Heat Test : shall be carried out in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2004) at 55 degree C for 16 hrs. (B) Damp Heat : shall be carried out at upper Temperature of 40 degree C,two cycles of (12+12 hours)each in accordance with IS:9000 (part 5/sec.2)1981 (reaffirmed 2004). (C) Cold Test : shall be carried out in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2004) at -10 degree C for 4 hrs. b. Acceptance Tests : Tests listed at Sl. No.i to viii shall constitute acceptance test. Acceptance test shall be carried out on all the items offered for inspection. Schedule 5 Line Interactive UPS with AVR for single phase AC 160V to 280V input. Unit : NOS. Specification : As per detailed specification and General Technical requirements. Rated KVA Minimum VAH

UPS27001055 0.5 / 84 UPS27001056 0.5 / 168 UPS27001057 0.5 / 400 UPS27001059 0.65 / 400 UPS27001061 0.8 / 168 UPS27001062 0.8 / 400 UPS27001063 0.8 / 216 UPS27001064 1.0 / 168 UPS27001065 1.0 / 400 UPS27001066 1.0 / 216 UPS27001068 1.5 / 800 UPS27001069 1.5 / 600 UPS27001070 2.0 / 800 UPS27001071 2.0 / 1600

(M.A. Ansari ) Incharge PS-II

Page 41: ups system

41 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/CN/4227 Dated: 26.09.2012 Tenderers to note : 1. Tenderers shall be reqistered for the product in the name of line interactive UPS. They shall be in Possession of TYPE Test Certificates, except Environmental tests, for each rating with highest VAH . However , the Environment Test Certificate only for the highest rating with highest VAH would be acceptable. These test certificates shall be from any Govt. laboratory . For CE or UL Certified Line Interactive UPS, tenderers shall be in possession of CE or UL Certificate for each item quoted and furnish copy thereof with their offer. 2. Tenderers shall declare charging voltage (DC bus voltage) and charging current for each item quoted in their offer. 3. Switching device shall be MOSFET or IGBT and the same shall be declared in the offer by the tenderers. 4. Switching frequency shall be above 50 Hz and shall be declared in the offer. 5. Tenderers hall declare battery AH Capacity , battery voltage , number of batteries of each rating , make and model of batteries offered woth each item of UPS corresponding to the specified minimum VAH rating of battery bank. 6. The Batteries shall be SMF VRLA Type as per JISC and the firms shall submit compliance certificate to the governing specification from OEM to QA officers at the time of inspection. Indentors to note : Typical power consumption of PC is 160 VA , of PC with inkjet printer is 300-400 VA and for PC with laser printer is 700-800 VA . The back up time as available for each item can be calculated on this basis by the indentor before ordering the item. Detailed Specification Schedule 5 Line Interactive UPS with AVR for single phase AC 160V to 280V input. Specification : Line Interactive UPS (CE or UL certified) with AVR and PWM technology for computers suitable for single phase AC input voltage range 160V to 280V, 50 +/-3 Hz and be housed in rugged enclosure made of M.S. Sheet of 1 mm (minimum) thick aesthetically finished , duly pretreated and powder coated or ABS body. Schedule 6 Line Interactive UPS (CE or UL Certified) with AVR for single phase AC 160V to 280V input. Specification : Line Interactive UPS (CE or UL certified) with AVR and PWM technology for computers suitable for single phase AC input voltage range 160V to 280V, 50 +/-3 Hz and single phase AC output voltage 230V +/-9%, 50+/-0.5 Hz in AC mode. It shall be housed in rugged enclosure made of M.S. sheet of 1 mm (minimum) thick aesthetically finished , duly pretreated and powder coated or ABS body. General Technical requirement For TE : A. Suppliers shall furnish complete & satisfactory type test certificate except Environmental test for each rating with highest VAH, however, the, the Environment test certificates only for the highest rating with highest VAH to the Director (QA) concerned at the time of inspection of first lot. TTC shall be from Govt. laboratory. Suppliers, who have already got type test certificates for the existing ratings, would not be required to obtain fresh type test certificates for the same ratings. For CE or UL certified Line Interactive UPS, supplier shall be in possession of CE or UL certificate for each item. B. The firm shall registered for the subject stores in the name of Line Interactive UPS. The type test report for the highest rating of the UPS will be acceptable only for the purpose of grant of registration. C. Specification for Line Interactive UPS with AVR for Computers and general purpose . 1. General (a) UPS shall be free from workmanship defects, sharp edges, nicks,scratches, burs, etc. All fasteners shall be fixed properly. The equipment shall be complete with all parts and all parts shall be functional. (b) Enclosures shall conform to protection requirement of IP2L1 to IS13947 (Part 1)/1993 (reaffirmed 2004). (c) Switching device shall be MOSFET or IGBT and the same shall be declared in the offer by the tenderers. (d) Switching frequency shall be above 50 Hz and shall be declared in the offer. 2. Switching over time from AC mains to UPS mode on power failure should be 10 milliseconds maximum. 3. Input : 160 to 280V, 50 +-3 Hz Single Phase AC. 4. Output : (a) AVR output voltage in AC mode : 230 Volts +/- 9 %, 50 +/- 3Hz. (b) UPS output voltage in battery mode : 230 volts +/-10%, 50 +/-0.5 Hz. At Load power factor of not less than 0.6 lag. 5. Total Harmonics distortion : 40% maximum to be mea sued in DC mode. 6. Efficiency (at rated output voltage and frequency) Inverter efficiency : Minimum 70%

(M.A. Ansari ) Incharge PS-II

Page 42: ups system

42 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/CN/4227 Dated: 26.09.2012 7. Regulation : Total variation of voltage from no load to full shall not exceed 10% and at no point the output voltage should go beyond the permissible band of 230 volts +/-9% 8. Overload : UPS shall withstand 10% overload for at least 10 minutes inmains node. 9. Protections: (a) Input voltage goes outside the range 160 to 280 Volts the system shalls witch over to battery mode. (b) Over voltage, short circuit, and overload at UPS output terminals. (c) Protection of battery terminals falls below 10.5 V for 12 Volts and 21V for 24 Volts battery system. 10. Indicators and meters: (i) Mains mode. (ii) UPS mode. (iii) Battery Low 11. Battery Bank: (a) The batteries shall be of 12 Volts Sealed Lead Acid Valve Regulated Type (VRLA) as per JISC: 8707/1992 or to JISC: 8702 /1998 & the supplier shall submit compliance certificate to the governing specification from OEM to the concerned D(QA) at the time of inspection (b) Suppliers shall declare battery AH Capacity, battery Voltage, number of batteries of each rating, make and model of batteries offered with each item of UPS corresponding to the specified minimum VAH rating of battery bank. (c) In case the batteries are not housed inside UPS cabinet, suitable enclosure/rack to mount these batteries shall also be supplied along with the batteries. 12. Freight charges for dispatch shall be per unit basis subject to the conditions specified in terms & conditions of T/e for various distanceslabs/regions/destinations. D. Testing requirement for UPS 1. Type tests : Following shall constitute the type testing. And shall be carried out at least on one unit of each rating (a) Visual examination (b) Verification of output power and frequency (c) Verification of voltage regulation. (d) Verification of efficiency (e) Verification of total harmonics distortion. (f) Verification over voltage protection. (g) Test for insulation resistance, leakage current and high voltage as per IS : 616/2003 (IEC 60065-2001) Insulation resistance should not be less than 100 mega ohms. (h) Test for minimum VAH capacity of the battery. (i) Capacity test (C20) and High rate Discharge shall also be carried out at the time of first inspection for each rating, make and model of battery at the firm's premises. 2. Environmental tests : Following environment tests shall be carried out. During the last 1/2 an hour of each environmental test functional tests functional tests, as at SL. No. 1, 2 further after each environmental test the functional performance mentioned at SL. No. (a) To (f) shall be checked after recovery period of 1 hour and test results shall be satisfactory. (a) Burn-inTest: At a temperature of 45 degree C for 48 hours with power on and at full load. (b) Dry Heat Test: At 45 degree C for 16 hrs in accordance with IS: 9000 (Part 3/Sec. 5)/1997). (Reaffirmed 2004) (c) Damp Heat Test: At 40 degree C, RH 95% for two cycles. In accordance with IS:: 9000 (Part 5/sec. 1) 1981 (Reaffirmed 2004) (d) Cold Test: At 0 degree C for 2 hrs in accordance with IS: 9000 (Part 2/Sec. 4)/1997). (Reaffirmed 2004) 3. Acceptance tests: Tests listed at SL. No. (a) To (h) shall constitute acceptance test and shall be carried out on all the items offered for inspection. Capacity test for the battery shall also be carried out as an acceptance test against each lot.

(M.A. Ansari )

Incharge PS-II

Page 43: ups system

43 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/CN/4227 Dated: 26.09.2012

SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)

---------------------------------------NIL ------------------------------------ ------------------------------------------------------------------------------------------------------------------------

(Subas Chandra Bhagat ) I/c Marketing-I

Page 44: ups system

44 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/CN/4227 Dated: 26.09.2012

SCHEDULE – “D”

FORMAT FOR QUATERLY DRAWAL REPORT

Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of

Department Quantity and Value of Orders Received (Rs.)

Quantity and Value of Orders Executed (Rs.)

Balance Quantity and Value to be Supplied (Rs.)

Reasons

Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.

Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges

2. Nil report should also be Submitted.

(Subas Chandra Bhagat ) I/c Marketing-I

Page 45: ups system

45 /59 Chhattisgarh State Industrial Development Corporation Limited (A Government of Chhattisgarh Undertaking) LIC Campus, Pandri Raipur 492 004 (C.G) Phone 91-771-2583789-90, Fax : 91-771-2583794, 4091879 Website: www.csidc.in, Email : [email protected], [email protected]

No./CSIDC/MKD/ PS- II / 12-13/ Raipur, Dated : Registered A/D Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/GN/4228 Dated: 26.09.2012 To,

M/s. Global Network Solutions, C/13, Shailendra Nagar Raipur CG -492001 Pho-07714094432, 8889871071

Sub :- Rate Contract for the supply of Item UPS System (Valid From dated 26.09.2012 to 25.09.2013)

Ref :- (I) This Office Tender Enquiry No. CSIDC/MKD/ PS- II / 71-291/12-13 (IV) Your Bid No. 5980 dated 24.07.2012 (V) Your Offer acceptance along with undertaking submitted on dated 22.09.2012

Dear Sir, You are hereby informed that your above referred tender read with subsequent letters mentioned above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be governed by the terms and conditions brought in CSIDC Form No.1 & 2 . The Rate Contract and the Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction .

You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the time of getting the payment . SCHEDULES ANNEXED : 1. Schedule “A” Description of Stores, Prices, Duties/Taxes . 2. Annexure -“A” Technical Particulars of Item UPS System

Item UPS System 3. Schedule “B” Special conditions of contract (if any). 4. Schedule “C” Information to DDOs about parallel rate contracts. 5. Schedule “D” Format for Drawal Report. Encl. 15 pages

Yours faithfully,

(Subas Chandra Bhagat ) I/c Marketing-I

For and on behalf of the purchaser named in CSIDC Form No.2

Page 46: ups system

46 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/GN/4228 Dated: 26.09.2012 Copy to, 1. The Secretary, Chhattisgarh Vidhan Sabha ,Raipur .

2. The Registrar, Honourable High court Chhattisgarh, Bilaspur .

3. The Accountant General Chhattisgarh State, Raipur.

4. All HODs of Chhattisgarh Govt. with a request to circulate the copy of R/C to all Direct Demanding Officers of your institution against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC, pre dispatched inspection of stores, also acceptance of store and ensure to endorse the copy of purchase order (Indent) to the CSIDC Ltd., for further approval of authorized pre dispatch Inspection Agency enlisted in the CSIDC panel.

5. All The Collectors ,Chhattisgarh State against issue of purchase order (Indent) in Favour of Rate Contract Holders of CSIDC, pre dispatched inspection of stores, acceptance of store and ensure to endorse the copy of purchase order (Indent) to the CSIDC Ltd., for further approval of authorized pre dispatch Inspection Agency enlisted in the CSIDC panel

6. The Director Treasury, Chhattisgarh Govt., Raipur with a request to circulate copy of R/C to all branches under your control

7. (i) The Director Directorate of Public Instruction, Pension bada, Raipur (ii) The Director Directorate of Tribal welfare & Backward Classes ,Pt.R.S.U. Campus Raipur (iii) The Commissioner , Local Administrator , RDA Building Raipur (iv) Engineer in Chief PWD C.G.Civil lines Raipur .

Sr. No. 1 to 7 above are requested to call for original INK-SIGNED Rate Contract for verification to their full satisfaction including validity of various documents like Registration, Tax Registration etc. before taking action i.e. release of supply order, inspection of stores, payment of bill whichever is applicable, as the responsibility rests with the concerned authority .

8. (i) ADG (Q & A) , DGS&D, Jeewan Tara Building 5 Parliament Street New Delhi 110001 (ii) Manager (Operation) Indian Register of Shipping, Senior MIG-2, Secter A, 1st Floor, Infront

of Bank of India Indrapuri Bhopal. (iii) Chief Engineer, PDIL, 4th floor, 4/2 Karaya Road, 67 Shekespeare Sarani, Kolkata (W.B.) (iv) General Manager (Inspection) RITES Ltd., Churchgate Station Road, Second Floor, M.K.

Road, Mumbai-400020 (v) Operations Manager SGS India Pvt, Ltd. 43, RR Arcade, Zone-2, MP Nagar, Bhopal (MP)-

462011. For information and necessary action against Authorized Inspection Agency accorded by CSIDC for inspection of stores.

9. Manager (Tender), Marketing Div., CSIDC Ltd., Raipur. He is requested to maintain a master file of Rate Contract.

10. Computer cell, CSIDC Ltd., Raipur to release Rate Contract on CSIDC website.

11. Main file of Item- UPS System

(Subas Chandra Bhagat )

I/c Marketing-I For and on behalf of the purchaser

Named in CSIDC Form No.2

Page 47: ups system

47 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/GN/4228 Dated: 26.09.2012

SCHEDULE “A” Description of Stores, Prices, Duties/Taxes

For the supply of Item- UPS System as per Annexure’A’ enclosed.

1. (a) NAME AND FULL ADDRESS OF :- M/s. Global Network THE FIRM Solutions, C/13, Shailendra Nagar Raipur CG -492001 Pho-07714094432, 8889871071

NAME AND FULL ADDRESS OF M/s. NPP Energy Limited , MANUFACTURER 1961/3, Arya Samaj Road, Near HDFC Bank,

Narela New Delhi

(b1) CATEGORY :- General

2. VALIDITY OF RATE CONTRACT :- From 26.09.2012 to 25.09.2013 6. DESCRIPTION OF ITEM- UPS System SPECIFICATION, UNIT RATE AS BELOW

Item Code No. Item Description Class Rate FOR Dest.

VAT/CST Extra As Applicable Rate Per Unit

1 2 3 Schedule1On-Line UPS with isolation transformer suitable for Three Phase AC Inputand Three Phase AC Output,Floor Mounted TypeUnit :NOS.Rating of UPS Indicative Back-Up time

UPS27001002 10 KVA / 60 minutes 164551.00 UPS27001004 15 KVA / 30 minutes 182864.00 UPS27001005 15 KVA / 60 minutes 229269.00 UPS27001006 15 KVA / 120 minutes 339528.00 UPS27001007 20 KVA / 30 minutes 223572.00 UPS27001008 20 KVA / 60 minutes 299996.00 UPS27001009 20 KVA / 120 minutes 458386.00 UPS27001010 30 KVA / 30 minutes 175680.00 UPS27001011 30 KVA / 60 minutes 370625.00 UPS27001012 30 KVA / 120 minutes 631731.00 Schedule-2 On-Line UPS with isolation transformer suitable for Three Phase AC Input and Single Phase AC Output,Floor Mounted Type Unit : NOS. Rating of UPS Indicative Back-Up time

UPS27001013 10 KVA / 30 minutes 104714.00 UPS27001014 10 KVA / 60 minutes 136899.00 UPS27001015 10 KVA / 120 minutes 191296.00 UPS27001016 15 KVA / 30 minutes 145965.00 UPS27001017 15 KVA / 60 minutes 178603.00 UPS27001018 15 KVA / 120 minutes 281958.00 UPS27001019 20 KVA / 30 minutes 161378.00 UPS27001020 20 KVA / 60 minutes 244786.00 UPS27001021 20 KVA / 120 minutes 389845.00 UPS27001022 30 KVA / 30 minutes 222121.00 UPS27001023 30 KVA / 60 minutes 351767.00 UPS27001024 30 KVA / 120 minutes 545784.00 Schedule4On-Line UPS with isolation transformer suitable for single phase AC input & single phase AC output, Floor Mounted TypeUnit :NOSating of UPS Indicative Back-up time

UPS27001043 5.0 KVA / 30 Minutes 55303.00 UPS27001044 5.0 KVA / 60Minutes 70716.00 UPS27001045 5.0 KVA / 120 Minutes 106980.00 UPS27001051 7.5 KVA / 120 Minutes 62733.00

(Subas Chandra Bhagat ) I/c Marketing-I

Page 48: ups system

48 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/GN/4228 Dated: 26.09.2012

Schedule5Line Interactive UPS with AVR for single phase AC 160V to 280V input.Unit :NOS.Specification:As per detailed specification and General Technical Requirements.Rated KVA Minimum VAH

UPS27001055 0.5 / 84 1469.00 UPS27001056 0.5 / 168 2457.00 UPS27001057 0.5 / 400 3826.00 UPS27001059 0.65 / 400 4170.00 UPS27001061 0.8 / 168 3055.00 UPS27001062 0.8 / 400 4597.00 UPS27001063 0.8 / 216 3581.00 UPS27001064 1.0 / 168 3654.00 UPS27001065 1.0 / 400 5553.00 UPS27001066 1.0 / 216 3762.00 UPS27001068 1.5 / 800 8794.00 UPS27001069 1.5 / 600 7797.00 UPS27001070 2.0 / 800 11015.00 UPS27001071 2.0 / 1600 13123.00 Schedule6Line Interactive UPS (CE or UL certified) with AVR for single phase AC160V to 280V input.Unit :NOS.Specification: As per detailed specification and General Technical Requirements.Rated KVA Minimum VAHRated KVA Minimum VAH

UPS27001072 0.5 / 84 1477.00 UPS27001073 0.5 / 168 2468.00 UPS27001074 0.5 / 400 3840.00 UPS27001075 0.65 / 168 2609.00 UPS27001076 0.65 / 400 4176.00 UPS27001077 0.65 / 108 2232.00 UPS27001078 0.8 / 168 3071.00 UPS27001079 0.8 / 400 4612.00 UPS27001080 0.8 / 216 3595.00 UPS27001081 1.0 / 168 3662.00 UPS27001082 1.0 / 400 5565.00 UPS27001083 1.0 / 216 4923.00 UPS27001084 1.0 / 800 7501.00 UPS27001088 2.0 / 1600 14055.00

Note :- Technical particulars as per Annexure A enclosed 4. TERMS OF DELIVERY : F. O. R Destination ( Any where in C.G.State ) 5. EXCISE DUTY : Not applicable 6. SALES TAX /VAT/CST : Extra as applicable

Tin No. 22101306420 Address:-

M/s. Global Network Solutions, C/13, Shailendra Nagar Raipur CG -492001

Pho-07714094432, 8889871071

7. DELIVERY PERIOD : With in 30 to 90 days 8. a. ANNUAL TURN OVER/ : NM

b. MONETARY LIMIT : NM

(Subas Chandra Bhagat )

I/c Marketing-I

Page 49: ups system

49 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/GN/4228 Dated: 26.09.2012 c. INSTALLED CAPACITY : (as per DGS&D Registration Certificate) Description Capacity/Annum

UPS System 4800 Nos

9. SLAB DISCOUNT (IF ANY) : Nil 10. PRICES : Prices are Firm and Final 11. MINIMUM QUANTITY IN : Not Mentioned. SINGLE SUPPLY ORDER 12. STATUS OF RC HOLDING : Manufacturer

FIRM 13. REGISTRATION STATUS : Manufacturer is Registered with DGS&D New Delhi DGS&D/Regn/DEL/S-1793/05/2524 dt 27.10.2010 to 11.10.2012 14 BIS LICENSE : NM 15. PAYING AUTHORITY : As Mentioned in supply order to be issued by Direct Demanding

Officers (DDOs). 16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each

consignment there-of will be made after receipt and acceptance of the stores by the consignee/interim consignee in full and good condition within 20 days as per SPR rule No.11, if the bills are in order. In case of delay in payment without any reason the department will be liable to pay interest as per prevailing bank rate. Bills are to be submitted in the prescribed form of the paying authority of purchaser / indenter and are to be supported with inspection note issued by the inspector and consignee’s Receipt Certificate .

17 INSPECTION AUTHORITY : Accorded by CSIDC Ltd. While receipt of copy of purchase Order(Indent) in Favour of authorized pre dispatched Inspection Agency enlisted in the CSIDC panel prior to submission of application from the Rate Contract Holders.

18 QUALITY ASSURANCE: a)Accorded by CSIDC Ltd. While receipt of copy of purchase

Order (Indent) in Favour of authorized pre dispatched Inspection Agency enlisted in the CSIDC panel prior to submission of application from the Rate Contract Holders.

b)Post-dispatch inspection by the committee constituted by the Direct Demanding Officers /Purchase Department .

OR Post Dispetch Inspection of Stores carried by the Inspection

Agency enlisted in the CSIDC prior to receiving of proposal from the end user/Purchase Department.

19. PLACE WHERE THE STORES At Manufacturer’s Factory at

ARE TO BE OFFERED FOR M/s. NPP Energy Limited , INSPECTION 1961/3, Arya Samaj Road, Near HDFC Bank, Narela New Delhi

20 INSPECTION CHARGES : Inspection charges 0.60%+ Service Tax As applicable to be

paid extra at the time of inspection to Quality Assurance Officer which will be billed by the unit along with bill of the material and will be reimbursed by the paying authority of DDO.

(Subas Chandra Bhagat ) I/c Marketing-I

Page 50: ups system

50 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/GN/4228 Dated: 26.09.2012 21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause

7, the Purchaser / DDOs may require the contractor to furnish a security deposit which shall be made after issue of the acceptance of the supply order within the period specified by the purchaser / DDOs. Such security deposit shall not ordinarily exceed 3% . The security shall be in form of Demand Drafts issued by any of the Scheduled Commercial Banks. No other form of security is to be accepted. The security deposit amount is to be refunded after successful completion of the supply.

22. Special Note 1. Purchasing Departments will ensure pre dispatch inspection of Materials. 2. Purchasing Departments will be responsible for ensuring the Quality of accepted materials. 3. Purchasing Departments will ensure sending copy of every order to this office.

(Subas Chandra Bhagat ) I/c Marketing-I

Page 51: ups system

51 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/GN/4228 Dated: 26.09.2012

Annexure - “A” Technical Particulars For On-Line UPS For IT Applications Schedule 1 On-Line UPS with isolation transformer suitable for Three Phase AC Input and Three Phase AC Output,Floor Mounted Type Unit : NOS. Rating of UPS Indicative Back-Up time

UPS27001002 10 KVA / 60 minutes UPS27001004 15 KVA / 30 minutes UPS27001005 15 KVA / 60 minutes UPS27001006 15 KVA / 120 minutes UPS27001007 20 KVA / 30 minutes UPS27001008 20 KVA / 60 minutes UPS27001009 20 KVA / 120 minutes UPS27001010 30 KVA / 30 minutes UPS27001011 30 KVA / 60 minutes UPS27001012 30 KVA / 120 minutes

Schedule 2 On-Line UPS with isolation transformer suitable for Three Phase AC Input and Single Phase AC Output,Floor Mounted Type Unit : NOS. Rating of UPS Indicative Back-Up time

UPS27001013 10 KVA / 30 minutes UPS27001014 10 KVA / 60 minutes UPS27001015 10 KVA / 120 minutes UPS27001016 15 KVA / 30 minutes UPS27001017 15 KVA / 60 minutes UPS27001018 15 KVA / 120 minutes UPS27001019 20 KVA / 30 minutes UPS27001020 20 KVA / 60 minutes UPS27001021 20 KVA / 120 minutes UPS27001022 30 KVA / 30 minutes UPS27001023 30 KVA / 60 minutes UPS27001024 30 KVA / 120 minutes

Schedule 4 On-Line UPS with isolation transformer suitable for single phase AC input & single phase AC output, Floor Mounted Type Unit : NOS. Rating of UPS Indicative Back-up time

UPS27001043 5.0 KVA / 30 Minutes UPS27001044 5.0 KVA / 60Minutes UPS27001045 5.0 KVA / 120 Minutes UPS27001051 7.5 KVA / 120 Minutes

(M.A. Ansari ) Incharge PS-II

Page 52: ups system

52 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/GN/4228 Dated: 26.09.2012 Questionnaire Schedule On-Line UPS with isolation transformer suitable for Three Phase AC Input and Single Phase AC Output,Floor Mounted Type 1 Online UPS for IT application 1.1 Charging voltage (DC Bus Voltage) 1.2 Charging current 1.3 Switching device (MOSFET/IGBT) 1.4 Switching frequency (should be more than 10kHz) 1.5 Battery AH capacity 1.6 Battery voltage 1.7 No of batteries 1.8 Make/Model of batteries Questionnaire Schedule On-Line UPS with isolation transformer suitable for single phase AC input & single phase AC output, Floor Mounted Type 1. Online UPS for IT application 1.1 Charging voltage (DC Bus voltage) 1.2 Charging current 1.3 Switching device (MOSFET /IGBT) 1.4 Switching frequency( (should be more than 10kHz) 1.5 Battery AH capacity 1.6 Battery voltage 1.7 No of batteries 1.8 Make/Model of batteries Questionnaire Schedule On-Line UPS with isolation transformer suitable for Three Phase AC Input and Three Phase AC Output,Floor Mounted Type 1 Online UPS for IT application 1.1 Charging voltage (DC Bus Voltage) 1.2 Charging current 1.3 Switching device (MOSFET/IGBT) 1.4 Switching frequency (should be more than 10kHz) 1.5 Battery AH capacity 1.6 Battery voltage 1.7 No of batteries 1.8 Make/Model of batteries General Technical requirement For TE : 1. General a. UPS shall be free from workmanship defects, sharp edges, nicks, scratches, burs, etc. All fasteners shall be fixed properly. The equipment shall be complete with all parts and all parts shall be functional. b. Enclosures shall conform to protection requirement of IP2L1 to IS13947 (part 1)/1993 (reaffirmed 1998). c. By-pass facility shall be provided for maintenance of UPS. d. UPS shall supply output power and charging current at the same time. e. Switching device shall be MOSFET or IGBT and the same shall be confirm in the offer. f. Switching frequency shall be above 10 KHz and shall be declared in the offer. g. KW rating of the UPS shall be 0.70 times the KVA rating. 2. Input (as applicable) a. 160V-260V, 50 +/-3% Hz single phase AC or b. 300V-450V, 50 +/-3%Hz three phase AC

(M.A. Ansari )

Incharge PS-II

Page 53: ups system

53 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/GN/4228 Dated: 26.09.2012 3. Output (as applicable) a. 230V +/-1% (with alternative setting for 220V +/-1%) 50 +/-0.5Hz, single phase. b. 400V +/-1% (with alternative setting for 380V +/-1%) 50 +/-0.5Hz three phase. Voltage regulation from no load to full load shall be within +/-1% in both the cases. UPS shall also have facility for operation in synchronous mode in which output frequency shall be same as that of mains frequency. 4. Total harmonics distortion at output : 2% maximum for UPS up to 5KVA and 3% maximum for UPS above 5 KVA on resistive load. If total input harmonics are less than or equal to 10%. 5. Efficiency (at rated output voltage and frequency) a. Overall efficiency (minimum) : 90% 6. UPS power factor at rated load : better than 0.9 lagging. 7. Over load : UPS shall withstand 20% overload for 10 minutes and 50% over load for one minute. 8. Protections : Following protection shall be provided in UPS: a. Over voltage, short circuit, and overload at UPS output terminal. b. Under voltage at battery terminal. c. Over shoot and under shoot shall not be greater than 4% of rated voltage for duration of 40m sec. (maximum) 9. Indicators and meters a. Following indicators shall be provided:- (i) Mains presence. (ii) Battery charging and discharging (iii) Output overload (iv) Low battery voltage. b. Digital meter shall be provided for monitoring the following parameters in UPS(not applicable for rack mounting): (i) Input AC voltage. (ii) Output AC Voltage, current and frequency (iii) Battery voltage and current. 10. Battery bank: a. UPS shall be supplied with SMF VRLA battery only. b. Tenderers shall declare battery AH capacity, battery voltage, number of batteries of each rating, make and model of batteries offered with each item of UPS. c. Batteries for UPS shall be of the following makes:- Exide, Panasonic, Amar Raja, Global, Rocket ,Base, RITAR make & DGS&D registered batteries or any other make duly type tested to JIS C 8702 from DGS&D approved lab. d. The UPS shall be complete with Trolley for battery bank and the firms shall also connect the batteries with UPS and commission the same. e. Minimum VAH rating of battery bank for different duration of back up time shall be as detailed below: UPS rating Min.VAH Min. VAH Min VAH Min. VAH in KVA 30 minute 60 minute 120 minute 240 minute back up back up back up back up 0.5 KVA 400 800 1600 3200 1 KVA 800 1600 3200 6400 2 KVA 1600 3200 6400 12800 3 KVA 2400 4800 9600 19200 5 KVA 4000 8000 16000 32000 6 KVA 4800 9600 19200 38400 7.5 KVA 6000 12000 24000 48000 10 KVA 8000 16000 32000 64000 15 KVA 12000 24000 48000 96000 20 KVA 16000 32000 64000 128000 30 KVA 24000 48000 96000 192000

(M.A. Ansari ) Incharge PS-II

Page 54: ups system

54 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/GN/4228 Dated: 26.09.2012 16. Testing requirement for UPS: a. Type Tests : Following shall constitute type test and at least one sample shall be type tested for each rating with maximum backup time. Type testing shall be conducted either atan independent govt. lab or at the premises of the manufacturer in presence of an officer from concerned Directorate of Quality Assurance. (i) Visual examination. (ii) Verification of output power and frequency. (iii) Verification of voltage regulation. (iv) Verification of efficiency. (v) Verification of total harmonics distortion. (vi) Verification of overshoot, undershoot limits and over voltage protection. (vii) Test for insulation resistance, leakage current high voltage as per IS:616/86 (reaffirmed in 1991. Insulation resistance should not be less than 100 mega ohms. (viii) Verification of VAH as per Rate Contract. (ix) Environmental tests: Following environmental tests shall be carried out on the highest rating. Tests at SL. No. i to iii above shall be repeated during the last half an hour of each environmental condition. Tests at Sl. No. i to vi shall be repeated after completing the environmental tests sequence of the three conditions and recovery period of 1 to 2 hours. There shall be no deterioration in any of these parameters when compared to the test results obtained before environmental tests (A) Dry Heat Test : shall be carried out in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2004) at 55 degree C for 16 hrs. (B) Damp Heat : shall be carried out at upper Temperature of 40 degree C,two cycles of (12+12 hours)each in accordance with IS:9000 (part 5/sec.2)1981 (reaffirmed 2004). (C) Cold Test : shall be carried out in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2004) at -10 degree C for 4 hrs. b. Acceptance Tests : Tests listed at Sl. No.i to viii shall constitute acceptance test. Acceptance test shall be carried out on all the items offered for inspection. Schedule 5 Line Interactive UPS with AVR for single phase AC 160V to 280V input. Unit : NOS. Specification : As per detailed specification and General Technical requirements. Rated KVA Minimum VAH

UPS27001055 0.5 / 84 UPS27001056 0.5 / 168 UPS27001057 0.5 / 400 UPS27001059 0.65 / 400 UPS27001061 0.8 / 168 UPS27001062 0.8 / 400 UPS27001063 0.8 / 216 UPS27001064 1.0 / 168 UPS27001065 1.0 / 400 UPS27001066 1.0 / 216 UPS27001068 1.5 / 800 UPS27001069 1.5 / 600 UPS27001070 2.0 / 800 UPS27001071 2.0 / 1600

Schedule 6 Line Interactive UPS (CE or UI, certified ) with AVR for single phase AC Unit : Nos. 160V to 280V input. Specification : As per detailed specification and General Technical Requirements. Rated KVA Minimum VAH

UPS27001072 0.5 / 84 UPS27001073 0.5 / 168 UPS27001074 0.5 / 400 UPS27001075 0.65 / 168

(M.A. Ansari )

Incharge PS-II

Page 55: ups system

55 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/GN/4228 Dated: 26.09.2012

UPS27001076 0.65 / 400 UPS27001077 0.65 / 108 UPS27001078 0.8 / 168 UPS27001079 0.8 / 400 UPS27001080 0.8 / 216 UPS27001081 1.0 / 168 UPS27001082 1.0 / 400 UPS27001083 1.0 / 216 UPS27001084 1.0 / 800 UPS27001088 2.0 / 1600

Tenderers to note : 1. Tenderers shall be reqistered for the product in the name of line interactive UPS. They shall be in Possession of TYPE Test Certificates, except Environmental tests, for each rating with highest VAH . However , the Environment Test Certificate only for the highest rating with highest VAH would be acceptable. These test certificates shall be from any Govt. laboratory . For CE or UL Certified Line Interactive UPS, tenderers shall be in possession of CE or UL Certificate for each item quoted and furnish copy thereof with their offer. 2. Tenderers shall declare charging voltage (DC bus voltage) and charging current for each item quoted in their offer. 3. Switching device shall be MOSFET or IGBT and the same shall be declared in the offer by the tenderers. 4. Switching frequency shall be above 50 Hz and shall be declared in the offer. 5. Tenderers hall declare battery AH Capacity , battery voltage , number of batteries of each rating , make and model of batteries offered woth each item of UPS corresponding to the specified minimum VAH rating of battery bank. 6. The Batteries shall be SMF VRLA Type as per JISC and the firms shall submit compliance certificate to the governing specification from OEM to QA officers at the time of inspection. Indentors to note : Typical power consumption of PC is 160 VA , of PC with inkjet printer is 300-400 VA and for PC with laser printer is 700-800 VA . The back up time as available for each item can be calculated on this basis by the indentor before ordering the item. Detailed Specification Schedule 5 Line Interactive UPS with AVR for single phase AC 160V to 280V input. Specification : Line Interactive UPS (CE or UL certified) with AVR and PWM technology for computers suitable for single phase AC input voltage range 160V to 280V, 50 +/-3 Hz and be housed in rugged enclosure made of M.S. Sheet of 1 mm (minimum) thick aesthetically finished , duly pretreated and powder coated or ABS body. Schedule 6 Line Interactive UPS (CE or UL Certified) with AVR for single phase AC 160V to 280V input. Specification : Line Interactive UPS (CE or UL certified) with AVR and PWM technology for computers suitable for single phase AC input voltage range 160V to 280V, 50 +/-3 Hz and single phase AC output voltage 230V +/-9%, 50+/-0.5 Hz in AC mode. It shall be housed in rugged enclosure made of M.S. sheet of 1 mm (minimum) thick aesthetically finished , duly pretreated and powder coated or ABS body. General Technical requirement For TE : A. Suppliers shall furnish complete & satisfactory type test certificate except Environmental test for each rating with highest VAH, however, the, the Environment test certificates only for the highest rating with highest VAH to the Director (QA) concerned at the time of inspection of first lot. TTC shall be from Govt. laboratory. Suppliers, who have already got type test certificates for the existing ratings, would not be required to obtain fresh type test certificates for the same ratings. For CE or UL certified Line Interactive UPS, supplier shall be in possession of CE or UL certificate for each item. B. The firm shall registered for the subject stores in the name of Line Interactive UPS. The type test report for the highest rating of the UPS will be acceptable only for the purpose of grant of registration. C. Specification for Line Interactive UPS with AVR for Computers and general purpose .

(M.A. Ansari ) Incharge PS-II

Page 56: ups system

56 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/GN/4228 Dated: 26.09.2012 1. General (a) UPS shall be free from workmanship defects, sharp edges, nicks,scratches, burs, etc. All fasteners shall be fixed properly. The equipment shall be complete with all parts and all parts shall be functional. (b) Enclosures shall conform to protection requirement of IP2L1 to IS13947 (Part 1)/1993 (reaffirmed 2004). (c) Switching device shall be MOSFET or IGBT and the same shall be declared in the offer by the tenderers. (d) Switching frequency shall be above 50 Hz and shall be declared in the offer. 2. Switching over time from AC mains to UPS mode on power failure should be 10 milliseconds maximum. 3. Input : 160 to 280V, 50 +-3 Hz Single Phase AC. 4. Output : (a) AVR output voltage in AC mode : 230 Volts +/- 9 %, 50 +/- 3Hz. (b) UPS output voltage in battery mode : 230 volts +/-10%, 50 +/-0.5 Hz. at Load power factor of not less than 0.6 lag. 5. Total Harmonics distortion : 40% maximum to be mea sued in DC mode. 6. Efficiency (at rated output voltage and frequency) Inverter efficiency : Minimum 70% 7. Regulation : Total variation of voltage from no load to full shall not exceed 10% and at no point the output voltage should go beyond the permissible band of 230 volts +/-9% 8. Overload : UPS shall withstand 10% overload for at least 10 minutes inmains node. 9. Protections: (a) Input voltage goes outside the range 160 to 280 Volts the system shalls witch over to battery mode. (b) Over voltage, short circuit, and overload at UPS output terminals. (c) Protection of battery terminals falls below 10.5 V for 12 Volts and 21V for 24 Volts battery system. 10. Indicators and meters: (i) Mains mode. (ii) UPS mode. (iii) Battery Low 11. Battery Bank: (a) The batteries shall be of 12 Volts Sealed Lead Acid Valve Regulated Type (VRLA) as per JISC: 8707/1992 or to JISC: 8702 /1998 & the supplier shall submit compliance certificate to the governing specification from OEM to the concerned D(QA) at the time of inspection (b) Suppliers shall declare battery AH Capacity, battery Voltage, number of batteries of each rating, make and model of batteries offered with each item of UPS corresponding to the specified minimum VAH rating of battery bank. (c) In case the batteries are not housed inside UPS cabinet, suitable enclosure/rack to mount these batteries shall also be supplied along with the batteries. 12. Freight charges for dispatch shall be per unit basis subject to the conditions specified in terms & conditions of T/e for various distanceslabs/regions/destinations. D. Testing requirement for UPS 1. Type tests : Following shall constitute the type testing. And shall be carried out at least on one unit of each rating (a) Visual examination (b) Verification of output power and frequency (c) Verification of voltage regulation. (d) Verification of efficiency (e) Verification of total harmonics distortion. (f) Verification over voltage protection. (g) Test for insulation resistance, leakage current and high voltage as per IS : 616/2003 (IEC 60065-2001) Insulation resistance should not be less than 100 mega ohms.

(M.A. Ansari ) Incharge PS-II

Page 57: ups system

57 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/GN/4228 Dated: 26.09.2012 (h) Test for minimum VAH capacity of the battery. (i) Capacity test (C20) and High rate Discharge shall also be carried out at the time of first inspection for each rating, make and model of battery at the firm's premises. 2. Environmental tests : Following environment tests shall be carried out. During the last 1/2 an hour of each environmental test functional tests functional tests, as at SL. No. 1, 2 further after each environmental test the functional performance mentioned at SL. No. (a) To (f) shall be checked after recovery period of 1 hour and test results shall be satisfactory. (a) Burn-inTest: At a temperature of 45 degree C for 48 hours with power on and at full load. (b) Dry Heat Test: At 45 degree C for 16 hrs in accordance with IS: 9000 (Part 3/Sec. 5)/1997). (Reaffirmed 2004) (c) Damp Heat Test: At 40 degree C, RH 95% for two cycles. In accordance with IS:: 9000 (Part 5/sec. 1) 1981 (Reaffirmed 2004) (d) Cold Test: At 0 degree C for 2 hrs in accordance with IS: 9000 (Part 2/Sec. 4)/1997). (Reaffirmed 2004) 3. Acceptance tests: Tests listed at SL. No. (a) To (h) shall constitute acceptance test and shall be carried out on all the items offered for inspection. Capacity test for the battery shall also be carried out as an acceptance test against each lot.

(M.A. Ansari )

Incharge PS-II

Page 58: ups system

58 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/GN/4228 Dated: 26.09.2012

SCHEDULE ‘B’ (SPECIAL CONDITION OF CONTRACT)

---------------------------------------NIL ------------------------------------ ------------------------------------------------------------------------------------------------------------------------

(Subas Chandra Bhagat ) I/c Marketing-I

Page 59: ups system

59 /59 Rate Contract No. CSIDC/MKD/ PS- II / 71-291/12-13/UPS/GN/4228 Dated: 26.09.2012

SCHEDULE – “D”

FORMAT FOR QUATERLY DRAWAL REPORT

Name of the Firm __________________ I- Jan-Mar Report No. __________________ II- Apr-June Rate Contract No. __________________ III- July-Sept. Date of Submission __________________ IV- Oct - Dec Total Position of Order against Rate Contract till the submission of Report. S.No. Name of

Department Quantity and Value of Orders Received (Rs.)

Quantity and Value of Orders Executed (Rs.)

Balance Quantity and Value to be Supplied (Rs.)

Reasons

Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.

Total value inclusive of all Taxes duties and incidental b) Value of orders supplied during the quarter-Rs. Charges

2. Nil report should also be Submitted.

(Subas Chandra Bhagat ) I/c Marketing-I