Page 2: User Guide: First Solar Series 4 Module

Series 4 Module User Guide—Global | Page i of 15

PD-5-200-04 | REV 3.1| 0348_UG_A4_11JUL17

Table of Contents

1 Introduction ...................................................................................................................................................................1

1.1 Before You Begin ..............................................................................................................................................1

1.2 Key Product Features .......................................................................................................................................1

1.3 Safety ...............................................................................................................................................................2

2 Regulatory Compliance ..................................................................................................................................................3

3 ElectricalSpecifications .................................................................................................................................................4

3.1 SystemDeratingFactors...................................................................................................................................4

4 Installation .....................................................................................................................................................................5

4.1 Mounting ..........................................................................................................................................................5

4.2 ModuleOrientation .........................................................................................................................................6

4.3 ModuleShadingConsiderations .......................................................................................................................7

4.4 ElectricalInterconnection ................................................................................................................................8

5 MechanicalSpecifications&Drawings.........................................................................................................................11

6 ProperOperatingConditions .......................................................................................................................................12

7 Service .........................................................................................................................................................................13

8 WarrantyTerms&Conditions ......................................................................................................................................13

9 Notice ..........................................................................................................................................................................14

10 Document References ..................................................................................................................................................15

Page 3: User Guide: First Solar Series 4 Module

Series 4 Module User Guide—Global | Page 1 of 15

PD-5-200-04 | REV 3.1| 0348_UG_A4_11JUL17

1 Introduction

FirstSolarSeries4andSeries4AModulesaremanufacturedinstate-of-the-artfacilitiesusingahighlyinnovativeprocessthatrapidlydepositsthinfilmsofsemiconductoronglass.Series4AmodulesareconstructedidenticallytoSeries4modulesandaddanti-reflectivecoatedglasstoSeries4modules.Themoduleshavebeendesignedtohavealongoperatinglifeandhighenergyyieldwheninstalled,operated,andservicedinaccordancewiththeinstructionsinthisUserGuide.FirstSolarSeries4andSeries4AModulesareelectricallyandmechanicallycompatiblewithoneanother,providedappropriatesystemdesignpracticesareemployed.Series4andSeries4AModulesarenotcompatiblewithFirstSolarSeries3Moduleswithinthe same interconnected string.

1.1 Before You Begin

This document provides guidelinesandinformationonFirstSolarSeries4andSeries4AModulesofmodeltypesFS-4xxx,FS-4xxxA,FS-4xxx-2,FS-4xxxA-2,FS-4xxx-3,andFS-4xxxA-3forsystemdesigners,installers,andmaintenancepersonnel.ReadthisUserGuidethoroughlybeforebeginninganyworkrelatedtotheinstallation,operation,ormaintenanceoftheFirstSolarSeries4orSeries4AModule.Onlyqualifiedpersonnelshouldinstall,operate,ormaintainaPVmoduleorsystem.

Failuretofollowinstallationandhandlinginstructionsmayresultininjury.

Failuretomaintainproperoperatingconditionrequirementsforthemoduleswillvoidtheapplicablewarranties.

Thisuserguideaddressestypicalmoduleinstallationandusageglobally.Certainregionsmayhaveadditionalrequirementsorconcerns.PleasecontactFirstSolar([email protected])orvisitwww.firstsolar.comforadditionalregionalUserGuidesthatmaybeavailable,orforadditionalsupport.

Keep this User Guide for future reference.

Guidelinesrelatedtosystemconstructionarebeyondthescopeofthisdocumentandarenotcoveredinthisdocument.

1.2 Key Product Features

• Highenergyyieldsinreal-worldconditions.

• Sizeandweightthatenablesefficienthandlingandinstallation.

• Easy,quick-connectwiringforfastinterconnection.

• Compatiblewithadvanced1500Vplantarchitectures

• Internationallyrecognizedproductcertifications.

• Twenty-fiveyearlimitedperformancewarranties.

Page 4: User Guide: First Solar Series 4 Module

Series 4 Module User Guide—Global | Page 2 of 15

PD-5-200-04 | REV 3.1| 0348_UG_A4_11JUL17

1.3 Safety

The Series 4 and Series 4A Modules may produce voltage up to 110 Volts DC (VDC) or current up to 3.0 Amps when exposed to sunlight. A single module could create a lethal shock hazard during hours of daylight, including periods of low light levels. The danger increases as modules are connected together in series and/or parallel.

To avoid fire and/or injury due to ground fault and associated electrical hazards:

• Do not unplug PV module connections while under load. Do not disconnect the module connectors during daylight hours unless the module is in an open circuit condition or all modules in series and parallel are covered with an opaque material, such as a tarp or blanket.

• Repair or replace damaged wires immediately. Keep all array wiring out of reach of non-qualified personnel.

• Do not concentrate light on the module in an attempt to increase power output.

• Never allow the PV array system voltage to exceed 1500VDC under any condition.

• Replace broken modules immediately.

• Repair any ground faults immediately.

• Do not work on modules or systems when the modules or wiring are wet.

Reverse currents higher than the rated values for a First Solar module (reverse current overload), may result in module failure, including module breakage. Extreme and continuous reverse current overload conditions may cause a fire or create electrical shock hazards. To avoid reverse current overload:

• Maintain equivalent voltage in parallel strings by installing an equal number of modules per string within the same source circuit. Failure to install modules with balanced voltage in parallel strings can result in voltage imbalance.

• Comply with all practices as stated in this document and repair ground faults.

It is the responsibility of the PV system installer to ensure compliance with all local building codes. As a minimum level of protection, all building mounted PV systems should utilize Ground Fault Circuit interrupters and Arc Fault Circuit Interrupters to minimize risk of electrical shocks and fires.

Wear safety glasses (ANSI Z87.1-2003) and cut-resistant gloves when working on non-interconnected modules or systems. Wear electrically rated PPE when working on interconnected modules or system components.

Series 4 and Series 4A Modules are not compatible with Series 3 Modules within the same interconnected string.

• To avoid risk of fire, do not interconnect Series 4/4A Modules within the same interconnected string as Series 3 Modules.

Page 5: User Guide: First Solar Series 4 Module

Series 4 Module User Guide—Global | Page 3 of 15

PD-5-200-04 | REV 3.1| 0348_UG_A4_11JUL17

2 Regulatory Compliance

Itistheresponsibilityoftheinstallerand/orsystemintegratortoensurecompliancewithalllocalelectricalcodeswhichmaybeapplicabletotheinstallationanduseofFirstSolarSeries4andSeries4AModules.

• BeforebeginningthePVsystemdesignandinstallation,contactappropriatelocalauthoritiestodeterminelocalcode,permit,andinspectionrequirements.

WhenusingMC4connectors,Series4andSeries4AModulesmeettherequirementsofProtectionClassIIfor1000VDCsystemsandProtectionClass0for1500VDCsystems.WhenusingMC4-EVO2connectors,Series4andSeries4AModulesmeettherequirementsofProtectionClassIIfor1000VDCand1500VDCsystems.Series4andSeries4AModulesaretestedandcertifiedperIEC61730withmaximumovercurrentprotectionratingsof4.0A.Series4andSeries4AModulesaretestedandcertifiedperIEC61646/IEC61215foramaximumsystemvoltageof1500V.

Page 6: User Guide: First Solar Series 4 Module

Series 4 Module User Guide—Global | Page 4 of 15

PD-5-200-04 | REV 3.1| 0348_UG_A4_11JUL17

3 Electrical Specifications

SeetheSeries4andSeries4AModuleProductSpecification(PD-5-101-04)andmodulelabelforallelectricalratingsofthemodule.AllelectricalratingsarelistedatStandardTestConditions(irradianceof1000W/m2,AM1.5spectrum,andacelltemperatureof25°C).

3.1 SystemDeratingFactors

Undernormaloperation,aphotovoltaicmodulemayexperienceconditionsthatproducemorecurrentand/orvoltagethanreportedatStandardTestConditions.Accordingly,thedatasheetandlabelspecificationvalueslistedforSTCshouldbemultipliedbyafactorof1.25forvoltageandcurrentwhendeterminingcomponentratings.Adjustmentsofthosefactorsmightbeneededtorespectsitespecificclimateconditions.

AsdefinedintheNationalElectricCodeandIEC62548,themaximumsystemvoltageforaPhotovoltaicSystemisdeterminedusingtheopencircuitvoltageofthePVmodules.

Page 7: User Guide: First Solar Series 4 Module

Series 4 Module User Guide—Global | Page 5 of 15

PD-5-200-04 | REV 3.1| 0348_UG_A4_11JUL17

4 Installation

4.1 Mounting

Physically damaged modules may cause ground faults and associated electrical hazards. To avoid these conditions:

Do not install the modules during high wind or wet conditions to reduce the likelihood of injury.

Wear safety glasses (ANSI Z87.1-2003) and cut-resistant gloves when working on non-interconnected modules or systems.

Wear electrically rated PPE when working on interconnected modules or system components.

• Handle modules with care during installation, as heavy impact on the front, back, or edges could result in damage to the module. Do not walk or stand on modules or retaining clips.

• Do not stack or carry multiple modules on top of one another after removal from factory packaging to minimize the risk of breakage.

• Do not lift or pull on modules using lead wires or strain relief wire loops to minimize the risk of wire damage.

MountingoftheSeries4andSeries4AModuletoasuitablestructurecanbedonebyattachingthemoduledirectlytothestructureusingretainingclips(seeFigure5.1).

Theinterfaceofthemountingstructuretothemodule(includingtheretainingclipandrubberinsulator)mustmeetthetechnicalrequirementsspecifiedinFirstSolarApplicationNotePD-5-320-04andmustbeapprovedforusebyFirstSolarpriortoinstallation.Themountingsystemdesignmustprovideadequatesupportforthemoduletopreventdamagefromoccurringwhenthemoduleissubjectedtopressuresof2400Pa(whichequatestowindpressureof130km/hour,withasafetyfactorof3forgustyconditionsbasedonIEC61646/IEC61215).Thelocationoftheclipsshallbealongthe1200mmlengthofthemoduleandthecenterpointoftheclipshallbelocatedbetween250mmand300mmfromthemoduleedge.SeeFigure5.1forallowedlocation.Rubberinsulatormaterial,orequivalentmustbeusedbetweenthemoduleandboththeclipandmountingstructuretoprovideadequateprotectionofthemoduleandmustmeetallrequirementsdescribedinPD-5-320-04ModuleMounting.Nodirectcontactofrigidstructuresispermittedagainstthesurfaceoredgesofthemodule.

Allmountingstructuresmustprovideaflatplaneforthemodulestobemountedon,andmustnotcauseanytwistorstresstobeplacedonthemodule.

Modulesshouldnotbeinstalledinawaythatrestrictsaircirculationtotheundersideofthemodule.Modulesgenerateheatandrequireadequateairflowforcooling.

Installationlocationsandmodulesupportstructuresshouldbeselectedtoensuremodulesandconnectors(openormated)areneversubmersedinstandingwater.FirstSolarmodulesaretestedandcertifiedforapplicationsinvolvingpressuresfromsnow/ice/windupto2400Pawhenmountedproperly.Snowdriftscouldresultinanonuniformloadingofthemoduleswhichexceedsthetestedpressure.Ifitisexpectedthatloadswillexceed2400Pa,itisrecommendedtoclearsnowfrom

!

!

!

!

Page 8: User Guide: First Solar Series 4 Module

Series 4 Module User Guide—Global | Page 6 of 15

PD-5-200-04 | REV 3.1| 0348_UG_A4_11JUL17

modules,andensurethatice/thaw/freezecyclesundersnowdriftsdonotresultinexcessivestressesonthemodule.

Heavyconstructionandtrenchingshouldbecompletedpriortomoduleinstallationtominimizedebrisanddust.

Ensureanysitepreparationormaintenancechemicals(soilbindingagentsorchemicalsusedforon-sitedustcontrolorweedcontrol)donotspray,splash,ordriftontothesurfaceofthemodulesoritsassociatedcomponents.

Maximumallowablepressureonmodulesmaynotexceed2400PawithoutadditionalmodulesupportthatmustbetestedandapprovedbyFirstSolartoreceiveaprojectspecificapproval.

Forrooftopmounting,modulesmustbemountedoverafireresistantroofcoveringratedfortheapplication.Therecommendedminimumstandoffheightis8cm.

4.1.1 Series 4A Module Installation Considerations (with Anti-Reflective Coating)

Handlewithglovestopreservevisualappearanceofanti-reflectivecoatedmodules(Series4A).

Duringhandlingandinstallation,avoidabrasivecontactwithtopglasssurfacetopreventscratchesofanti-reflectivecoatingon Series 4A modules.

Donotremovecardboardseparatorpaperbeforeremovingmodulesfrombox.DoingsomayresultinscratchesoftheARCfilmwhenpullingmodulesoutofthebox.

WhencleaningAnti-ReflectiveCoatedmodules,specificmodulecleaningguidelinesdocumentedinPD-5-804ModuleCleaningGuidelinesmustbefollowed.FailuretocomplywiththeModuleCleaningGuidelinesmayvoidwarranty.

BasiccleaningguidelinesforAnti-ReflectiveCoatedmodulesareasfollows:

AllowableCleaningMethods

• Lowpressurenon-contact watercleaningmaybeusedwithunlimitedcycles(i.e.watersprayisallowed,butscrubbingorbrushingwithwaterisprohibited).

• Drycleaningwithsoftclothmopsuptosixtimesannually

ProhibitedCleaningMethods

• Wetcontactcleaning(i.e.combiningwaterwithmops,brushes,squeegees)

• Drycontactcleaningwithanythingotherthansoftclothsormops(i.e.bristlebrushes,sponges,orsqueegees).

4.2 ModuleOrientation

PVperformancemodelingsoftwareshouldbeusedtodeterminetheoptimumorientationandtiltangleforeachlocation.

Fortiltedfree-fieldapplicationsorsingle-axistrackerapplicationswherethereisrow-to-rowshading,modulesshallbeinstalledinlandscapeorientation.

Page 9: User Guide: First Solar Series 4 Module

Series 4 Module User Guide—Global | Page 7 of 15

PD-5-200-04 | REV 3.1| 0348_UG_A4_11JUL17

4.3 ModuleShadingConsiderations

Tomaximizeperformance,modulesshouldbelocatedinanareathatreceivesdirectsunlightfrommid-morningtomid-afternoon(typically9:00a.m.to3:00p.m.).Installationmustavoidlocatingthemoduleswhereshadowsmaybecausedbybuildings,trees,etc.

Specificshadingpatternscancausedamagetomodulecellsduetothecreationoflocalizedareasofreversebias.Reversebiasisgeneratedbyoneormoreseries-connectedcellsbeingshadedwhiletherestofthecellsarefullyilluminated.Whenshadinggeometryissuitablefordamagetooccur,itcanhappeninveryshortdurations(secondstominutes)andunderawiderangeofirradiance(aslowas160W/m2).Anexampleofprohibitedshadingorientationispresentedbelow.

Thereisnoriskofmoduledamagedueto“row-to-row”shadinginlandscapeorientation.Thereisalsonoriskifshadingoccurswhilemodulesareinopencircuitconditionsornoriskfromdiffuseshadingforobjectsgreaterthan2metersor7feet.

Thereisalowriskofmoduledamageduetoshadingfromwalkingorstandinginfrontofoperatingmodulesorfromparkingordrivingvehiclesinfrontofoperatingmodulesduringilluminatedtimes.Bestpracticeistostayclosetothebacksideoftheadjacentrackasonetravelsdownarowofoperatingmodules.

InstancesofshadingthatwillleadtoavoidedwarrantyincludetheHighRiskitemslistedbelow.

High Risk (Prohibited) Shading

1. Restingoradheringslenderobjects(tools,brooms,clothing,wires,tape)onsunnysideofoperatingmodules,orwhennearerthan~1.5-2metersaboveoperatingmodules,especiallywhenshadoworientedparalleltocells.

2. Fixedobjectswithin~1.5-2metersaboveoperatingmodulesthatcastashadowoverthelongdimensionofthecells.Closeobjectslikeposts,ropes,signs,fences,orequipmentcanbegintoincreaseriskofpartialshadingoffullcellswhennearerthan~1.5-2metersfromthesunny-sideofoperatingmodule.

3. Asupportframeormountingmethodontheshortedge(s)ofmodulesthatfullyshadestheentirelengthofacell(eitherpartiallyorcompletely).

4. Workingcontinuouslywithoutstretchedarmsortoolsoveroperatingmodules.

5. Cleaningapparatuses,includingcleaningrobotsandothermechanismsthattraversethemodulerepeatedlywhilethesystemisoperating(unlessevaluatedandapprovedbyFirstSolar).

Page 10: User Guide: First Solar Series 4 Module

Series 4 Module User Guide—Global | Page 8 of 15

PD-5-200-04 | REV 3.1| 0348_UG_A4_11JUL17

4.4 ElectricalInterconnection

FirstSolarSeries4andSeries4AModulesarepre-configuredwithindustrystandardconnectorsthatare“touchproof”withalllivepartsprotectedagainstaccidentalcontactandprotectedagainstpolarityreversal.ThecablesandMC4connectorsareUVandweatherresistantfrom–40°Cto+85°C,andratedfor1500VDCand22.5A(minimum,beforederatingforambienttemperature).ThecablesandMC4-EVO2connectorsareUVandweatherresistantfrom–40°Cto+85°C,andratedfor1500VDCProtectionClassIIapplicationsand39A(ambienttemperature).

Modules with different FS Series numbers (i.e. FS 3 vs. FS 4) have significantly different electrical operating characteristics and should not be interconnected within the same inverter or MPPT to prevent power output loss and voltage imbalance conditions that may create the risk of reverse current overload.

Damaged wires, connectors, or junction boxes may cause ground faults, and associated electrical hazards, including electrical shock. To avoid these conditions:

• Protect unmated connectors from dust and moisture by using sealing caps (not provided, available from connector manufacturer).

• Limit module connectors to 10 or fewer plug cycles.

• Do not pull lead wires tight at any time. After installation, the connected wire must not be under stress or tension.

• Do not use junction box assembly or lead wire strain relief loops to secure excess wire or to bear weight greater than that of a (properly wire managed) module’s own wire and mated connector pair.

• Connector bodies and cables should not be tightly secured at both ends to any mounting structure to allow for thermal expansion and contraction.

• Secure wire or connected components so that no loose wires or components are hanging within 0.46m (1.5 feet) of the ground in free field applications, and so that wire/components are hanging clear of roof coverings or pooled water in rooftop applications.

• Ensure connectors are fully mated.

• Ensure wire securement methods, such as use of cable ties, do not damage wire insulation. The minimum module lead wire bend radius is 5 times wire diameter. Observe minimum bend radius specifications on all other PV system wiring.

• Ensure wires are not in contact with sharp edges of the mounting structure to avoid abrading the wire sheath.

• Inspect and maintain wire management requirements over the life of the plant.

!

!

Page 11: User Guide: First Solar Series 4 Module

Series 4 Module User Guide—Global | Page 9 of 15

PD-5-200-04 | REV 3.1| 0348_UG_A4_11JUL17

Componentsusedtointerconnectthemodulesmustbecompatiblewiththeconnectors,andprovidepropersystemoperationandfaultprotectionasrequiredbyanyapplicablecodesandstandards.

Module-to-moduleandmodule-to-harnessinterconnectionisadvisedtobedonebetweensamemanufacturerandtypeofconnectorsorusingconnectorscertifiedasmateable.TheFirstSolarmodulewarrantyisnotaffectedbytheinterconnectionofdifferentsupplierconnectors,however,FirstSolarcannotguaranteethatconnectorsfromdifferentmanufacturerswillbemateableineveryconnectioninstance.

Connector Identification

MC4connectorsofpartnumbers(PV-KST4/PV-KBT4)

MC4-EVO2connectorsofpartnumbers(PV-KST-EVO2/PV-KBT-EVO2)

Connectormanufacturerwebsite:http://ec.staubli.com/

4.4.1 Inverter Compatibility

Series4andSeries4AModulesaredesignedforutilitygridconnected,commercialandindustrial,off-gridenergyaccess,andfueldisplacementapplications.FirstSolarFSSeriesPVModulesarecompatiblewitharangeofstring,central,andtransformerlessinverters.Whenconnectingmodulesormodulestringsinseriesensureinverterratingsareappropriate.

WhenconnectingFirstSolarSeries4and/orSeries4AModulesinaseriesstring,ensurethatthesystemdesignvoltageandinverterdesignspecificationsarenotexceeded.For1000VDCapplications,thisistypicallyensuredbylimitingseriesstringsto10modulesorless.For1500VDCapplications,thisistypicallyensuredbylimitingseriesstringsto15modulesorless.

TheMaximumPowerPoint(MPP)voltageofamodulearraymustbeconsideredforcompatibilitywiththespecifiedMPPwindowoftheinverter.Similartothemaximumopen-circuitvoltage,theMPPvoltageofthearrayisdependentonambientconditions,andthesystemshouldbedesignedtoensurethattheMPPvoltageofthearrayremainswithintheMPPwindowforexpectedoperatingconditions.

Whenselectinganinverter,systembiasconditionsandgroundingshouldalsobeconsidered.FSSeriesPVModulescanbe

Page 12: User Guide: First Solar Series 4 Module

Series 4 Module User Guide—Global | Page 10 of 15

PD-5-200-04 | REV 3.1| 0348_UG_A4_11JUL17

usedinnegative-groundedorungroundedinstallations.Useinbi-polarsystemsshouldbereviewedindetailbyFirstSolarpriortoapproval.FSSeriesPVModulesshouldnotbeusedinpositive-groundedsystems.

4.4.2 Grounding Method

FirstSolarSeries4andSeries4AModuleshavenoexposedconductivesurfacesanddonotrequireequipmentgroundingaslongasacliplengthof100mmforastandard4clipmountingisnotexceeded.

FirstSolarSeries4andSeries4AModulescanbeusedinnegative-grounded,ungrounded,floating,andbi-polarsystemarchitectures,providedallappropriatedesignrequirementsaremetandapprovedbyFirstSolar.FSSeriesPVModulesshouldnotbeusedinpositive-groundedsystems.

4.4.3 Overcurrent Protection

Series4andSeries4AModuleshaveamaximumovercurrentprotectionratingof4.0AasdefinedbyIEC61730testmethods.

PVsystemsshouldbedesignedtocomplywithandprovidemoduleovercurrentprotectionconsistentwithlocalcodesasappropriatefortheintendedapplicationclassofthesystem.

Connectionofparallelstringsmustincorporatemeasurestoprotectmodulesagainstreversecurrentsexceedingtheirrating.

PleaserefertoFSApplicationNotePD-5-308foradditionalinformationonmoduleovercurrentprotection.

Page 13: User Guide: First Solar Series 4 Module

Series 4 Module User Guide—Global | Page 11 of 15

PD-5-200-04 | REV 3.1| 0348_UG_A4_11JUL17

5 Mechanical Specifications & Drawings

Table 5.1: Mechanical Specifications

Specifications Series4&Series4AModules

Length 1200 mm

Width 600 mm

Thickness 6.8 mm

Total Area 0.72 m2

IndividualLeadwire1 657 mm

LeadwireConnectionSpan2 1314 mm

Weight 12kg

Fire Performance Type3 Type 10 ModuleClass A Spread of FlameClass B Burning Brand

OperatingTemperature -40°Cto+85°C

1Minimum from strain relief to connector mating surface²Minimum from positive strain relief to negative strain relief of adjacent module3Roof mounted fire rating is established by assessing rack and module as a unit

Figure 5.1 Mechanical Drawing for Series 4 and Series 4A Modules

Page 14: User Guide: First Solar Series 4 Module

Series 4 Module User Guide—Global | Page 12 of 15

PD-5-200-04 | REV 3.1| 0348_UG_A4_11JUL17

6 Proper Operating Conditions

Theproperoperatingconditionrequirementslistedbelowmustbemaintained.

Important: Failure to maintain proper operating condition requirements for the modules will void the applicable warranties.

Requirements:

• Shortcircuitoperationispermittedonlyduringshortdurationsystemsafetytestingorinfail-safesystemstates.

• Allelectroniccomponentsthatareinterconnectedtomodulesmustberatedforthemaximumoperatingvoltageofthearray,musthaveanoperatingvoltagewindowthatmatchesthemaximumpowerpointofthearray,andmustbecapableofoperatingthearrayatthemaximumpowerpoint.

• Modulesmusthaveadequateventilationandairflowtopreventoperatingtemperaturesabove85°C.

• Modulerow-to-rowshadinginlandscapeorientationisacceptable;Modulerow-to-rowshadinginportraitorientationisprohibited.

• Strainreliefcabletiesmustnotberemoved.

• Ifmodulecleaningisundertaken,modulesmustbecleanedonlywheninopencircuit–eitherdisconnectedfromload,orduringtimeswheninverteristurnedoffandotherwiseinaccordancewithPD-5-804“FSSeriesPVModuleCleaningGuidelines”.

• Series4AModulesincludeanti-reflectivecoatedglass.Useofprohibitedcleaningmethodscanreducetheenergyenhancingeffectsoftheanti-reflectivecoatedglassandvoidwarranty.PleaseconsultPD-5-804“FSSeriesPVModuleCleaningGuidelines”forallowablecleaningmethodscompatiblewithSeries4AModules.

• ModuleboxesmustbehandledperPD-5-801BoxHandlingandStorage.FailuretofollowtheBoxHandlingandStorageguidelinesmayresultindamagetomodulesthatwouldnotbecoveredundertheModuleWarrantyTermsandConditions.

Page 15: User Guide: First Solar Series 4 Module

Series 4 Module User Guide—Global | Page 13 of 15

PD-5-200-04 | REV 3.1| 0348_UG_A4_11JUL17

7 Service

Cleaning activities create risk of damage to the modules and array components, as well as the potential for electric shock.Largeamountsofdustanddirtonthesurfaceofthemodulecanreducethepowerproduced.Naturalrainfallwilltypicallyremovemostdust.Shouldauxiliarycleaningberequired,pleaserefertotheModuleCleaningGuidelines(PD-5-804)foradditionalinformation.FailuretocomplywiththeModuleCleaningGuidelinesmayvoid

warranty.

Broken modules should be replaced immediately. Periodically,annuallyataminimum,inspectmodulesforanysignsofdamageorbrokenglass.Ifbrokenmodulesarefound,placematerialintoaclosedcontainerforreturntoFirstSolarrecyclingprogram,ordisposeofmoduleinaccordancewithlocalrequirements.Pleasevisitwww.firstsolar.com/recyclingforfurtherdetailsontherecyclingprogram.

• Itisnormalforthemodulestoexhibitvisualirregularitieswhichdonotimpactpower.Series4AModuleswithanti-reflectivecoatedglassaremorelikelytoexaggeratethevisualappearanceofnormalscratches,fingerprints,andotherblemishesduetotheopticalpropertiesoftheglassinterface.

• Checkthatallelectricalconnectionsaretightandcorrosionfree.

ThemostcommoncausesoflowerthanexpectedPVsystempoweroutputare:

• Inverter failure

• Improperorfaultyfieldwiringorconnections

• Blownfusesortrippedcircuitbreakers

• Excessiveamountsofdirtanddustonthemodules

• Shadingofmodulesbytrees,poles,orbuildings

• Improperlycalibratedormalfunctioningmonitoringequipment

8 Warranty Terms & Conditions

Pleasereferto“FirstSolarFSSeriesModuleWarrantyTerms&Conditions”forindividualmodulewarrantyterms,limitations,andproductreturnpolicies.

!

!

Page 16: User Guide: First Solar Series 4 Module

Series 4 Module User Guide—Global | Page 14 of 15

PD-5-200-04 | REV 3.1| 0348_UG_A4_11JUL17

9 Notice

ChangestocertaincomponentsofthemodulearecommonasFirstSolarcontinuouslystrivesforproductimprovements.Changesmaybearesultofcomponentimprovementsorchangesbyasupplier,orbyminordesignmodificationsinitiatedbyFirstSolar.Allproductswithinthesamemodelclassificationremainfunctionallyequivalentandfullycompatiblewithoneanother,eventhoughtheremaybeslightdifferences,providedappropriatesystemdesignpracticesareemployed.Modificationsthatdonotimpactthefunctionalityoftheproductwilltypicallybemadewithoutcustomernotification.Internaltesting,andrevieworretestingbyacertifyingagency,willbecompletedbeforecomponentordesignchangesareintroduced into the manufacturing process.

FirstSolarreservestherighttomakechangesinsolarmoduledesignand/orspecificationsatanytimewithoutnotice.Accordingly,thereaderiscautionedtoverifythatdatasheetsarecurrentbeforeplacingordersorfinalizingsystempermittingand/ordesign.InformationfurnishedbyFirstSolarisbelievedtobeaccurateandreliable.However,noresponsibilityisassumedbyFirstSolaroritssubsidiariesforitsuse;norforanyinfringementsofpatentsorotherrightsofthirdpartieswhichmayresultfromitsuse.NolicenseisgrantedbyimplicationorotherwiseunderanypatentorpatentrightsofFirstSolaroritssubsidiaries.

IntheeventofaconflictbetweenthismoduleUserGuideandtheinstructionsofoneofthesystemcomponentmanufacturers,thesystemcomponentinstructionsshouldprevail.

ForinformationregardingFirstSolaranditsproducts,pleasevisitwww.firstsolar.com.Fortechnicalsupport,[email protected].

Global

FirstSolar,Inc. P.O.Box730 Toledo,OHUSA43697-0730

Tel: +1(602)414-9300 Fax: +1(602)414-9400 Web: www.firstsolar.com Email: [email protected]

Page 17: User Guide: First Solar Series 4 Module

Series 4 Module User Guide—Global | Page 15 of 15

PD-5-200-04 | REV 3.1| 0348_UG_A4_11JUL17

10 Document References

DocumentNumber Document Title

PD-5-101-04 FirstSolarSeries4PVModuleProductSpecification

PD-5-320-04 FSSeries4PVModuleMounting

PD-5-804 FSSeriesPVModuleCleaningGuidelines

PD-5-308 FSSeriesPVModules-ReverseCurrentOverload

PD-5-801 FSSeriesPVModule-BoxHandlingandStorage