1 Model UT601: OPERATING MANUAL Table of Contents Title Page Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Functional Buttons Display Symbols Measurement Operation A. Measuring Resistance B. Capacitance Measurement C. Diode and Continuity Test D. Transistor hFE Measurement General Specifications Accuracy Specifications A. Resistance Test B. Capacitance Test C. Continuity & Diodes D. Transistor Maintenance A. General Service B. Replacing the Battery C. Replacing the Fuse 3 4 5 6 8 9 9 10 11 11 13 15 17 18 19 19 20 20 21 22 22 23 24

Upload: angelo-antunes

Post on 19-Oct-2015

5 views

Category:

Documents


0 download

TRANSCRIPT

  • 1Model UT601: OPERATING MANUAL

    Table of ContentsTitle PageOverviewUnpacking InspectionSafety InformationRules For Safe OperationInternational Electrical SymbolsThe Meter StructureFunctional ButtonsDisplay SymbolsMeasurement Operation A. Measuring Resistance B. Capacitance Measurement C. Diode and Continuity Test D. Transistor hFE MeasurementGeneral SpecificationsAccuracy Specifications A. Resistance Test B. Capacitance Test C. Continuity & Diodes D. TransistorMaintenance A. General Service B. Replacing the Battery C. Replacing the Fuse

    345689910111113151718191920202122222324

  • 2Model UT601: OPERATING MANUAL

  • To avoid electric shock or personal injury, read theSafety Information and Rules for Safety Operationcarefully before using the Meter.

    Warning

    3

    Model UT601: OPERATING MANUAL

    OverviewThis Operating Manual covers information on safety andcautions. Please read the relevant information carefullyand observe all the Warnings and Notes strictly.

    Digital Capacitance Meter Model UT601 (hereafter referredto as the Meter) is a 3 1/2 digits with steady operations,fashionable design and highly reliable hand-held measuringinstrument. The Meter can also measure resistance,transistor, diode and continuity buzzer.

    The Meter has a broad capacitance measurement rangeand precise accuracy. It can be used in measuring thecircuit designed capacitance of cable, switch and PCBlayout.

  • 4Model UT601: OPERATING MANUAL

    Unpacking InspectionOpen the package case and take out the Meter. Checkthe following items carefully to see any missing or damagedpart:

    Item Description Qty1

    2

    3

    English Operating Manual

    Test Clip

    9V Battery (NEDA1604, 6F22 or 006P)

    (installed)

    1 piece

    1 pair

    1 piece

    In the event you find any missing or damage, please contactyour dealer immediately.

  • Safety InformationThis Meter complies with the standards EMC EN61326.

    Use the Meter only as specified in this operating manual,otherwise the protection provided by the Meter may beimpaired.

    In this manual, a Warning identifies conditions and actionsthat pose hazards to the user, or may damage the Meteror the equipment under test.

    A Note identifies the information that user should payattention on.

    International electrical symbols used on the Meter and inthis Operating Manual are explained on page 8.

    5

    Model UT601: OPERATING MANUAL

  • To avoid possible electric shock or personal injury,and to avoid possible damage to the Meter or to theequipment under test, adhere to the following rules:

    Warning

    Before using the Meter inspect the case. Do not usethe Meter if it is damaged or the case (or part of thecase) is removed. Look for cracks or missing plastic.Pay attention to the insulation around the connectors.Inspect the test clips for damaged insulation orexposed metal. Check the test clips for continuity.Replace damaged test clips with identical modelnumber or electrical specifications before using theMeter.Do not apply voltage to the Meter.The rotary switch should be placed in the rightposition and no any changeover of range shall bemade during measurement is conducted to preventdamage of the Meter.Do not apply more than 30Vrms between theterminals and the grounding to avoid electric shockand damage to the Meter.Use the proper terminals, function, and range foryour measurements.Do not use or store the Meter in an environment ofhigh temperature, humidity, explosive, inflammableand strong magnetic field. The performance of theMeter may deter iorate af ter dampened.Disconnect circuit power and discharge all high-voltage capacitors before testing resistance,continuity, capacitance or diodes.Replace the battery as soon as the battery indicator appears. With a low battery, the Meter mightproduce false readings that can lead to electric shockand personal injury.Remove test clips from the Meter and turn the Meterpower off before opening the Meter case.

    l

    l

    ll

    l

    l

    l

    l

    l

    l

    Rules For Safe Operation

    6

    Model UT601: OPERATING MANUAL

  • When servicing the Meter, use only the same modelnumber or identical electrical specificationsreplacement parts.The internal circuit of the Meter shall not be alteredat will to avoid damage of the Meter and any accident.Soft cloth and mild detergent should be used toclean the surface of the Meter when servicing. Noabrasive and solvent should be used to prevent thesurface of the Meter from corrosion, damage andaccident.The Meter is suitable for indoor use.Turn the Meter power off when it is not in use andtake out the battery when not using for a long time.Please constantly check the battery as it may leakwhen it has been using for some time, replace thebattery as soon as leaking appears. A leaking batterywill damage the Meter.

    l

    l

    l

    l

    l

    7

    Model UT601: OPERATING MANUAL

  • 8Model UT601: OPERATING MANUAL

    International Electrical Symbols

    Grounding

    Double Insulated

    Deficiency of Built-In Battery.

    Continuity Test.

    Diode.

    Capacitance Test

    Fuse.

    Warning. Refer to the Operating Manual.

    Conforms to Standards of European Union.

  • 9Model UT601: OPERATING MANUAL

    The Meter Structure (see figure 1)

    Functional Buttons

    1. LCD Display2. Capacitance Zero Adjustment Switch3. Transistor Jack4. Resistance, Diode and Continuity Buzzer Input Terminal5. Capacitance Input Terminal6. Small Value Capacitance Jack7. Rotary Switch .8. Power Button

    (figure 1)

    Below table indicated for information about the functionalbutton operations.

    Button Description

    Press the Power down to turn the Meter on. Press

    the Power again to turn the Meter power off.Power

    1

    2

    3

    6

    7

    8

    5 4

  • 10

    Model UT601: OPERATING MANUAL

    Display Symbols (see figure 2)

    (figure 2)

    Data hold is active.

    The battery is low.

    Warning: To avoid false readings, which

    could lead to possible electric shock or

    personal injury, replace the battery as soon

    as the battery indicator appears.

    Transistor Test

    Test of diode.

    The continuity buzzer is on.

    Farad. The unit of capacitance

    pF: Picofarad. 1x10-12 or 0.000000000001

    farads.

    nF: Nanofarad. 1x10-9 or 0.000000001 farads.

    F: Microfarad.1x10-6 or 0.000001 farads.

    mF: Millifarad. 1x10-3 or 0.001 farads.

    : Ohm. The unit of resistance

    k : ki lohm. 1x103 or 1000 ohms

    M : Megaohm. 1x106 or 1,000,000 ohms

    H: Henry. The unit of Inductance.

    mH: Millihenry. 1x10-3 or 0.001 henry.

    No. Symbol Meaning

    1

    2

    3

    4

    5

    6

    7

    8

    pF, nF,

    F, mF

    , k ,

    M

    H, mH

    mFFnFpF

    mHH

    kM

    3

    1

    2

    5

    4

    6

    8

    7

  • Make sure the Low Battery Display is not on,otherwise false readings may be provided.Pay extra attention to the symbol, before carryingmeasurement, which is located besides the inputterminals of the Meter.

    l

    l

    To avoid damages to the Meter or to the devices undertest, disconnect circuit power and discharge all thehigh-voltage capacitors before measuring resistance.

    Warning

    The resistance ranges are 20 , 200 , 2k , 20k , 200k ,2M , 20M , 200M and 2000M .

    To measure resistance, please connect the Meter asfollows:

    Insert the red test clip into the terminal andthe black test clip into COM terminal.Set the rotary switch to range.Connect the test clips across with the object beingmeasured.The measured value shows on the display.

    1.

    2.3.

    11

    Model UT601: OPERATING MANUAL

    Measurement Operation

    A. Measuring Resistance (see figure 3)

    (figure 3)

  • When measuring at 20 and 200 range, the test clipscan add 0.1 to 0.3 error to resistance. To obtain precisereadings in these low-resistance measurement, that isthe range 20 and 200, short circuit the input terminalsbeforehand and record the reading obtained (called thisreading as X). (X) is the additional resistance from thetest clips.Then use the equation:measured resistance value (Y) (X) = precision readingsof resistance.The Meter displays 1 when there is no input, forexample, open circuit situation.For high resistance measurement (>1M), it is normaltaking several seconds to obtain a stable reading.When resistance measurement has been completed,disconnect the connection between the testing clips andthe circuit under test and remove the testing clips awayfrom the input terminals of the Meter.

    l

    l

    l

    l

    12

    Model UT601: OPERATING MANUAL

    Note

  • To avoid damage to the Meter or to the equipmentunder test, disconnect circuit power and dischargeall high-voltage capacitors before measuringcapacitance. Use the DC Voltage function to confirmthat the capacitor is discharged.

    Warning

    The Meters capacitance ranges are:200pF, 2nF, 20nF,200nF, 2F, 20F, 200F, 2mF and 20mF.

    To measure capacitance, connect the Meter as follows:

    Set the rotary switch to F measurement mode. If thevalue of capacitor to be measured is unknown, use theminimum measurement position 200pF and increasethe range step by step until a satisfactory reading isobtained and the overloading icon 1 is disappeared.Insert the red test clip into the CAP + terminal and blacktest clip into the CAP terminal. For small valuecapacitor measurement, insert the capacitor into theSmall Value Capacitance Jack.Use the red test clip to clip the capacitors positive andthe black test clip to clip the capacitors negative whenthe capacitor has polarity.

    1.

    2.

    3.

    13

    Model UT601: OPERATING MANUAL

    B. Capacitance Measurement (see figure 4)

    (figure 4)

  • Do not short the test clips to avoid the consumption ofbattery.To minimize the effect of capacitance stored in the testclips, the test clips should be as short as possible anduse the Small Value Capacitance Jack when measuringsmall value of capacitance.When capacitance measurement has been completed,disconnect the connection between the testing clips andthe circuit under test and remove the testing clips awayfrom the input terminals of the Meter.

    l

    l

    l

    When measuring small value capacitor, that is 200pF,2nF and 20nF, first open circuit the test clips or theSmall Value Capacitance Jack, then turn theCapacitance Zero Adjustment Switch to adjust zero.The measured value shows on the display.

    4.

    5.

    14

    Model UT601: OPERATING MANUAL

    Note

  • To avoid damages to the Meter or to the devices undertest, disconnect circuit power and discharge all thehigh-voltage capacitors before measuring diodes andcontinuity.

    Testing Diodes

    Warning

    Use the diode test to check diodes, transistors, and othersemiconductor devices. The diode test sends a currentthrough the semiconductor junction, and then measuresthe voltage drop across the junction. A good silicon junctiondrops between 0.5V and 0.8V.

    To test a diode out of a circuit, connect the Meter as follows:Insert the red test clip into the terminal andthe black test clip into the COM terminal.Set the rotary switch to .For forward voltage drop readings on any semiconductorcomponent, place the red test clip on the componentsanode and place the black test clip on the componentscathode.The display shows the diode forward voltage dropsnearest value.

    1.

    2.3.

    15

    Model UT601: OPERATING MANUAL

    C. Diode and Continuity Test (see figure 5)

    (figure 5)

    red

  • In a circuit, a good diode should still produce a forwardvoltage drop reading of 0.5V to 0.8V; however, thereverse voltage drop reading can vary depending on theresistance of other pathways between the probe tips.Connect the test clips to the proper terminals as saidabove to avoid error display. The LCD will display 1indicating open-circuit for wrong connection. The unit ofdiode is Volt (V), displaying the positive-connectionvoltage-drop value.When diode measurement has been completed,disconnect the connection between the testing clips andthe circuit under test and remove the testing clips awayfrom the input terminals of the Meter.

    l

    l

    l

    To test for continuity, connect the Meter as below:Insert the red test clip into the terminal andthe black test clip into the COM terminal.Set the rotary switch to .Connect the test clips across with the object beingmeasured.The beeper comes on continuously when the testresistance

  • To measure transistor, set up the Meter as follows:Check that the transistor is PNP or NPN type.Insert the transistor to be measured to the correspondingTransistor Jack.The Meter displays the tested transistors nearest value.

    When transistor measurement has been completed,disconnect the connection between the testing clips andthe circuit under test and remove the testing clips awayfrom the input terminals of the Meter.

    l

    17

    Model UT601: OPERATING MANUAL

    D. Transistor hFE Measurement (see figure 6)

    (figure 6)

    1.2.

    3.

    Note

    NPN

    PNP

    hFE

  • Fused Protection for capacitance Input Terminal: 0.315A,250V, fast type fuse, 5x20 mm.Maximum Display: Display: 1999.Measurement Speed: Updates 2-3 times /second.Polarity: Auto. (Display - when negative)Overloading: Display 1Range: Manual RangingCapacitance range zero adjustment:The range around 20pFTemperature:

    Operating: 0oC~40oC (32oF ~104oF).Storage: -10oC~50oC (14oF ~122oF).

    Relative Humidity: 75% @ 0oC - 30oC; 50% @ 31oC - 40oC.

    Altitude: Operating: 2000 m.Storage: 10000 m.

    Battery Type:One piece of 9V NEDA1604 or 6F22 or 006P.Battery Deficiency: DisplayDimensions (HxWxL): 172 x 83 x 38 mm.Weight: Approximate 310g (battery included).Safety/Compliances: EMC EN61326.Certification: , UL & CUL pending.

    l

    llllll

    l

    l

    l

    l

    lllll

    18

    Model UT601: OPERATING MANUAL

    General Specifications

  • Accuracy: (a% reading + b digits), guarantee for 1 year.Operating temperature: 23oC 5oC.Relative humidity:
  • Overload Protection0.315A, 250V, fast type fuse, 5x20 mmIf the Meter can not adjust to zero, you could use thetested values minus the open circuit value to get thecorrect measurement value.Measure of Capacitance: 1F=103mF = 106F = 109nF= 1012pF

    l

    l

    l

    Diode:Open Circuit Voltage around 2.8V.ContinuityAround < 120 , beeper comes on continuously.

    l

    l

    20

    Model UT601: OPERATING MANUAL

    B. Capacitance Test

    Range Resolution AccuracyTesting

    Frequency

    200.0pF

    2.000nF

    20.00nF

    200.0nF

    2.000F

    20.00F

    200.0F

    2.000mF

    20.00mF

    0.1pF

    0.001nF

    0.01nF

    0.1nF

    0.001F

    0.01F

    0.1F

    0.001mF

    0.01mF

    (0.5%+10)

    (2%+2)

    800Hz

    80Hz

    8Hz

    Remarks:

    C. Continuity & Diodes

    Range ResolutionOverload

    ProtectionFunction

    Diode

    Continuity

    1mV

    1250V rms

    Remarks:

  • The display value is the tested transistors nearest value(0~1000).l

    21

    Model UT601: OPERATING MANUAL

    D. Transistor

    Range ResolutionOverload

    Protection

    hFEVce 2.8V

    I bo 10A250V rms

    Remarks:

    Testing

    Condition

    1

  • This section provides basic maintenance informationincluding battery and fuse replacement instruction.

    Do not attempt to repair or service your Meter unlessyou are qualified to do so and have the relevantcalibration, performance test, and service information.

    To avoid electrical shock or damage to the Meter, donot get water inside the case.

    Warning

    Periodically wipe the case with a damp cloth and milddetergent. Do not use abrasives or solvents.To clean the terminals with cotton bar with detergent, asdirt or moisture in the terminals can affect readings.Turn the Meter power off when it is not in use and takeout the battery when not using for a long time.Do not store the Meter in a place of humidity, hightemperature and strong magnetic field.

    l

    l

    l

    l

    22

    Model UT601: OPERATING MANUAL

    Maintenance

    A. General Service

  • To avoid false readings, which could lead to possibleelectric shock or personal injury, replace the batteryas soon as the battery indicator appears.

    Warning

    Turn the Meter power off and remove all connectionsfrom the terminals.Remove the screw from the battery compartment, andseparate the battery compartment from the case bottom.Remove the battery from the battery compartment.Replace the battery with a new 9V battery (NEDA1604,6F22 or 006P)Rejoin the case bottom and battery compartment, andreinstall the screw.

    1.

    2.

    3.4.

    5.

    23

    Model UT601: OPERATING MANUAL

    B. Replacing the Battery (see figure 7)

    (figure 7)

    To replace the battery:

  • To avoid electrical shock or arc blast, or personalinjury or damage to the Meter, use specified fusesONLY in accordance with the following procedure.

    Warning

    To replace the Meters fuse:Turn the Meter power off and remove all connectionsfrom the terminals.Remove the screw from the battery compartment, andseparate the battery compartment from the case bottom.Remove the screws from the case bottom, and separatethe case top from the case bottom.Remove the fuse by gently prying one end loose, thentake out the fuse from its bracket.Install ONLY replacement fuses with the identical typeand specification as follows and make sure the fuse isfixed firmly in the bracket.Fuse 1: 0.315A, 250V, fast type fuse, 5x20 mm.Rejoin the battery compartment and the case top, andreinstall the screw.Rejoin the case bottom and case top, and reinstall thescrews.

    1.

    2.

    3.

    4.

    5.

    6.

    7.

    24

    Model UT601: OPERATING MANUAL

    C. Replacing the Fuse (see figure 8)

    (figure 8)

    SCREW

  • ** END **

    Replacement of the fuses is seldom required. Burning ofa fuse always results from improper operation.

    25

    Model UT601: OPERATING MANUAL

  • Copyright 2005 Uni-Trend Group Limited.All rights reserved.

    Manufacturer:Uni-Trend Technology (Dongguan) LimitedDong Fang Da DaoBei Shan Dong Fang Industrial Development DistrictHu Men Town, Dongguan CityGuang Dong ProvinceChinaPostal Code: 523 925

    Headquarters:Uni-Trend Group LimitedRm901, 9/F, Nanyang Plaza57 Hung To RoadKwun TongKowloon, Hong KongTel: (852) 2950 9168Fax: (852) 2950 9303Email: [email protected]://www.uni-trend.com

    26

    Model UT601: OPERATING MANUAL