validation part3
TRANSCRIPT
![Page 1: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/1.jpg)
Validation | Slide 1 of 43 August 2006
Validation
Supplementary Training Modules on Good Manufacturing Practice
WHO Technical Report Series, No. 937, 2006. Annex 4.
![Page 2: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/2.jpg)
Validation | Slide 2 of 43 August 2006
ValidationValidation
Part 1. General overview on qualification and validation
Part 2. Qualification of HVAC and water systems
Part 3. Cleaning validation
Part 4. Analytical method validation
Part 5. Computerized system validation
Part 6. Qualification of systems and equipment
Part 7. Non sterile product process validation
![Page 3: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/3.jpg)
Validation | Slide 3 of 43 August 2006
Cleaning Validation
Part 3
Supplementary Training Modules on Good Manufacturing Practice
WHO Technical Report Series, No. 937, 2006. Annex 4. Appendix 3
![Page 4: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/4.jpg)
Validation | Slide 4 of 43 August 2006
ValidationValidation
Objectives
To discuss principles and approaches to cleaning validation including:
Protocols and reports Personnel and equipment Use of detergents Microbiology Sampling Analytical methods and Acceptable limits
![Page 5: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/5.jpg)
Validation | Slide 5 of 43 August 2006
ValidationValidation
Principle
The objectives of GMP include prevention of possible contamination and cross-contamination
Contamination by a variety of substances– contaminants (e.g. microbes, previous products (both API
and excipient residues), residues of cleaning agents, airborne materials (e.g. dust and particulate matter), lubricants and ancillary material, such as disinfectants
Also decomposition residues from product or detergents
1.1 – 1.2
![Page 6: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/6.jpg)
Validation | Slide 6 of 43 August 2006
ValidationValidation
Principle (2)
Adequate cleaning procedures important
Documented evidence needed - cleaning procedure will provide clean equipment, suitable for intended use.
What is the objective of cleaning validation?– product, detergent and microbial residues– prevent possible contamination and cross-contamination
1.3 – 1.4
![Page 7: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/7.jpg)
Validation | Slide 7 of 43 August 2006
ValidationValidation
Principle (3)
Where is cleaning validation required?– Not necessarily for non-critical cleaning, e.g. between
batches of the same product (or different lots of the same intermediate in a bulk process), or of floors, walls, the outside of vessels, and following some intermediate steps.
– Considered important in multiproduct facilities - should be performed, e.g. for equipment, sanitization procedures and garment laundering.
1.5 – 1.6
![Page 8: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/8.jpg)
Validation | Slide 8 of 43 August 2006
ValidationValidation
Scope
Guidelines: General aspects of cleaning validation
Excluding specialized cleaning or inactivation– e.g. for removal of viral or mycoplasmal contaminants in
the biological manufacturing industry.
Normally cleaning validation needed for critical cleaning, e.g.– between manufacturing of one product and another– contact surfaces (products, drug products and API).
2.1 – 2.2
![Page 9: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/9.jpg)
Validation | Slide 9 of 43 August 2006
ValidationValidation
General
Written SOPs for cleaning processes – validated
Cleaning policy and cleaning validation procedure to cover:– contact surfaces;– cleaning after product changeover;– between batches in campaigns;– bracketing products for cleaning validation; and– periodic evaluation and revalidation of the number of
batches manufactured between cleaning validations.
3.1 – 3.2
![Page 10: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/10.jpg)
Validation | Slide 10 of 43 August 2006
ValidationValidation
General (2)
The company has to prove consistency
What are the variables when a cleaning procedure is followed?
How many consecutive applications of the cleaning procedure should be performed?
Training of personnel
3.3, 5.1
![Page 11: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/11.jpg)
Validation | Slide 11 of 43 August 2006
ValidationValidation
Cleaning validation protocols
Approved by QC or QA and to cover, e.g.– disassembly of system;– pre-cleaning;– cleaning agent, concentration, solution volume, water
quality;– time and temperature;– flow rate, pressure and rinsing;– complexity and design of the equipment;– training of operators; and– size of the system. 4.1.1 – 4.1.2
![Page 12: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/12.jpg)
Validation | Slide 12 of 43 August 2006
ValidationValidation
Cleaning validation protocols (2)
The cleaning validation protocol should include:– objectives, responsible people; – description of the equipment including the make, model,
serial number or other unique code; – time intervals; bioburden; cleaning procedures; – equipment used for routine monitoring (e.g. conductivity
meters, pH meters and total organic carbon analysers);– number of cleaning cycles; sampling procedures (e.g.
direct sampling, rinse sampling, in process monitoring and sampling locations) and the rationale for their use
4.1.3
![Page 13: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/13.jpg)
Validation | Slide 13 of 43 August 2006
ValidationValidation
Cleaning validation protocols (3)
The cleaning validation protocol should include (2):– data on recovery studies (efficiency of the recovery of the
sampling technique should be established); – analytical methods; – acceptance criteria (with rationale for setting the specific
limits) including a margin for error and for sampling efficiency;
– cleaning agent to be used;– revalidation requirements.
4.1.3
![Page 14: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/14.jpg)
Validation | Slide 14 of 43 August 2006
ValidationValidation
Cleaning validation protocols (4)
Cleaning agent used, scientifically justified and based on: – the solubility of the materials to be removed;– the design and construction of the equipment and surface
materials to be cleaned;– the safety of the cleaning agent;– the ease of removal and detection;– the product attributes;– the minimum temperature and volume of cleaning agent
and rinse solution; and– the manufacturer's recommendations 4.1.3
![Page 15: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/15.jpg)
Validation | Slide 15 of 43 August 2006
ValidationValidation
Cleaning validation protocols (5)
Bracketing:
Very similar cleaning procedures for products and processes - no need for individual validation. “Worst case” may be acceptable and should be justified.
Consider type of products and equipment; allowed only where products are similar in nature or property and processed on the same equipment; and identical cleaning procedures used.
4.1.4 – 4.1.6
![Page 16: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/16.jpg)
Validation | Slide 16 of 43 August 2006
ValidationValidation
Cleaning validation protocols (6)
Bracketing:
Representative product - most difficult to clean.
Equipment - only when it is similar or the same equipment in different sizes (e.g. 300 l, 500 l and 1000 l tanks).
– Alternative approach may be to validate the smallest and the largest sizes separately.
4.1.7 – 4.1.8
![Page 17: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/17.jpg)
Validation | Slide 17 of 43 August 2006
ValidationValidation
Cleaning validation reports
The relevant cleaning records – (signed by the operator, checked by production and reviewed by quality assurance) – and source data (original results) should be kept.
The results of the cleaning validation should be presented in cleaning validation reports stating the outcome and conclusion.
4.2.1
![Page 18: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/18.jpg)
Validation | Slide 18 of 43 August 2006
ValidationValidation
Equipment
Cleaning of contact surfaces to be validated, with consideration to “non-contact” parts. Critical areas should be identified.
Dedicated equipment for:– products which are difficult to clean, – equipment which is difficult to clean, – products with a high safety risk where it is not possible to
achieve the required cleaning acceptance limits using a validated cleaning procedure.
6.1– 6.2
![Page 19: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/19.jpg)
Validation | Slide 19 of 43 August 2006
ValidationValidation
Equipment (2)
If one SOP for cleaning a piece of equipment, review:– products being produced, – cleaning in a large campaign, – cleaning between batches of different products.
The design of equipment may influence the effectiveness of the cleaning process.
Consider design, e.g. V-blenders, transfer pumps or filling lines.
6.3 – 6.4
![Page 20: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/20.jpg)
Validation | Slide 20 of 43 August 2006
Basic Principles of GMPBasic Principles of GMP
Which are the critical areas for sampling?
What would be considered an appropriate approach for cleaning validation for this piece of equipment?
![Page 21: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/21.jpg)
Validation | Slide 21 of 43 August 2006
Basic Principles of GMPBasic Principles of GMP
Which are the critical areas for sampling?
What would be considered an appropriate approach for cleaning validation for this piece of equipment?
![Page 22: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/22.jpg)
Validation | Slide 22 of 43 August 2006
ValidationValidation
Detergents
Released by quality control and meet food standards or regulations
Composition known
Easily removed with rinsing - demonstrated - with acceptable limits defined
If persistent residues (e.g. cationic detergents) - avoided
Consider also detergent breakdown7.1 – 7.4
![Page 23: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/23.jpg)
Validation | Slide 23 of 43 August 2006
ValidationValidation
Microbiology
Prevent microbial growth and remove contamination Documented evidence
– routine cleaning
– storage of equipment The period and conditions
– storage of unclean equipment before cleaning
– between cleaning and equipment reuse Equipment stored in a dry condition after cleaning (no stagnant
water) Control of bioburden important 8.1 – 8.5
![Page 24: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/24.jpg)
Validation | Slide 24 of 43 August 2006
Basic Principles of GMPBasic Principles of GMP
What is important about cleaning validation for components/ parts of equipment?
Consider also the different materials, e.g. stainless steel contact surfaces, silicon seals and others
![Page 25: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/25.jpg)
Validation | Slide 25 of 43 August 2006
ValidationValidation
Sampling (General)
Clean as soon as possible after use– especially topical products, suspensions and bulk drug or– where the drying of residues will directly affect the
efficiency of a cleaning procedure
Two methods of sampling:– direct surface sampling and – rinse samples
Combination of the two - most desirable9.1.1 – 9.1.2
![Page 26: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/26.jpg)
Validation | Slide 26 of 43 August 2006
ValidationValidation
Sampling (General) (2)
Re-sampling: – not to be done before or during cleaning
Constant re-testing and re-sampling:– can show that the cleaning process is not validated– may indicate presence of unacceptable residue and
contaminants resulting from an ineffective cleaning process
9.1.3
![Page 27: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/27.jpg)
Validation | Slide 27 of 43 August 2006
ValidationValidation
Direct surface sampling (direct method)
Most commonly used method
Use “swabs” (inert material) - type of sampling material should not interfere with the test
Factors to be considered include:– supplier of the swab,– area swabbed, number of swabs used, whether they are
wet or dry swabs,– swab handling and swabbing technique
9.2.1
![Page 28: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/28.jpg)
Validation | Slide 28 of 43 August 2006
ValidationValidation
Direct surface sampling (direct method) (2)
Other factors include:– location from which the sample is taken (including worst
case locations, identified in the protocol)– composition of the equipment (e.g. glass or steel)
Critical areas (hardest to clean)– e.g. in semi-automatic/fully automatic clean-in-place
systems
Use appropriate sampling medium and solvent9.2.2 – 9.2.4
![Page 29: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/29.jpg)
Validation | Slide 29 of 43 August 2006
ValidationValidation
Rinse samples (indirect method)
Allows sampling of:– a large surface – areas that are inaccessible or that cannot be routinely
disassembled
Provides an "overall picture"
Useful for checking for residues of cleaning agents
In combination with other sampling methods such as surface sampling
9.3.1
![Page 30: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/30.jpg)
Validation | Slide 30 of 43 August 2006
ValidationValidation
Rinse samples (indirect method) (2)
The manufacturer has to provide evidence that samples are accurately recovered
What is considered acceptable in terms of recovery?
9.3.2
![Page 31: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/31.jpg)
Validation | Slide 31 of 43 August 2006
Validation
Recovery
> 80% is considered good
![Page 32: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/32.jpg)
Validation | Slide 32 of 43 August 2006
Validation
Recovery
> 80% is considered good >50% is considered
reasonable
![Page 33: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/33.jpg)
Validation | Slide 33 of 43 August 2006
Validation
Recovery
<50% is consideredquestionable
> 80% is considered good >50% is considered
reasonable
![Page 34: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/34.jpg)
Validation | Slide 34 of 43 August 2006
ValidationValidation
Batch placebo method
A placebo batch is manufactured and checks are done for carry-over of the previous product
– Expensive and laborious process– Little assurance that the contaminants are dislodged– Particles not necessarily uniformly dispersed– Method used in conjunction with rinse and/or surface
sampling method(s)– Samples taken throughout the process of manufacture– Sensitivity of the assay may be greatly reduced by dilution
of the contaminant 9.4
![Page 35: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/35.jpg)
Validation | Slide 35 of 43 August 2006
ValidationValidation
Analytical methods
Validated analytical methods – able to detect residuals or contaminants:
– specific for the substance(s) being assayed– at an appropriate level of cleanliness (sensitivity)
Sensitive and specific - may include:– chromatographic methods (e.g. high pressure liquid
chromotography (HPLC), gas chromotography (GC), and high pressure thin-layer chromatography (HPTLC)). Others include (alone or in combination), e.g. total organic carbon (TOC), pH, conductivity, ultraviolet (UV) spectroscopy, and ELISA
10.1, 10.2, 10.5
![Page 36: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/36.jpg)
Validation | Slide 36 of 43 August 2006
ValidationValidation
Analytical methods (2)
Validation of the analytical method should include, e.g.– precision, linearity and selectivity (the latter if specific
analytes are targeted);– limit of detection (LOD);– limit of quantitation (LOQ);– recovery, by spiking with the analyte; and– reproducibility
Detection limit (sufficiently sensitive) to detect the established acceptable level of residue / contaminants
10.3 – 10.4
![Page 37: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/37.jpg)
Validation | Slide 37 of 43 August 2006
ValidationValidation
Establishing acceptable limits
Limits: Practical, achievable and verifiable
Rationale: Logical, based on knowledge of materials
Each situation assessed individually
Principal reactant and other chemical variations
Screening (thin-layer chromatography) in addition to chemical analyses where necessary
11.1 – 11.3
![Page 38: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/38.jpg)
Validation | Slide 38 of 43 August 2006
ValidationValidation
Establishing acceptable limits (2)
There should be no residue from:
Previous product
Reaction by-products and degradants
Cleaning process itself (e.g. detergents or solvents)
Remember: Uniform distribution of contaminants is not guaranteed
11.4
![Page 39: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/39.jpg)
Validation | Slide 39 of 43 August 2006
ValidationValidation
Establishing acceptable limits (3)
The limit-setting approach can:– be product-specific– group products into families and choose a worst case
product– group products into groups according to risk, e.g. very
soluble products, products with similar potency, highly toxic, or difficult to detect products
– use different safety factors for different dosage forms based on physiological response (this method is essential for potent materials)
11.5
![Page 40: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/40.jpg)
Validation | Slide 40 of 43 August 2006
ValidationValidation
Establishing acceptable limits (4)
Limits may be expressed as:– a concentration in a subsequent product (ppm), – limit per surface area (mcg/cm2), or – in rinse water as ppm.
Limits for carry-over of product residues should meet defined criteria.
What are the three most commonly used criteria?
11.6 – 11.8
![Page 41: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/41.jpg)
Validation | Slide 41 of 43 August 2006
ValidationValidation
Establishing acceptable limits (5)
The three most commonly used criteria are:
– Visually clean No residue visible on equipment after cleaning. Spiking studies to determine the concentration at which most active ingredients are visible. (May not be suitable for high potency, low-dosage drugs.)
– No more than 10 ppm of one product will appear in another product (basis for heavy metals in starting materials).
– No more than 0.1% of the normal therapeutic dose of one product will appear in the maximum daily dose of a subsequent product.
11.9
![Page 42: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/42.jpg)
Validation | Slide 42 of 43 August 2006
ValidationValidation
Establishing acceptable limits (6)
The most stringent of three options should be used
Certain allergenic ingredients and highly potent material should be undetectable by the best available analytical methods
– e.g. penicillins and cephalosporins– e.g. anovulent steroids, potent steroids and cytotoxics
Dedicated manufacturing facilities needed
11.10 – 11.11
![Page 43: Validation Part3](https://reader034.vdocuments.net/reader034/viewer/2022042512/55d746d5bb61ebe2108b45cb/html5/thumbnails/43.jpg)
Validation | Slide 43 of 43 August 2006
ValidationValidation
Group session