Operator TrainingMCM-100S
12 June 2013 Stefaan Verkest – version 00
Agenda
1. Key features of the product
2. Identification of main parts
3. Powering the system on/off
4. Connections
5. On Screen Display (OSD) or ‘Menu’
6. Basic operations
7. Maintenance
8. Warnings
9. Limitations and restrictions
10.Diagnostics
11. List of available documentation
12.Who to contact in case of problems
MCM-100S2
13jun132
Key features of the product (1)
Image processing box HDTV (1920x1080) or WUXGA resolution (1920x1200) Designed for multi-projector V&AR display systems▫ Geometry correction (Warping)
▫ Color alignment (Dynacolor)
▫ Edge blending (Soft edge)
▫ Image correction on a pixel-by-pixel base (Alpha/Beta planes)
3D stereo▫ Active stereo up to 120Hz
▫ StereoCreator
▫ Synchronization between boxes
MCM-100S3
Key features of the product (2)
Output can run synchronously with selected input
Controlled via RCU (IR) or XDS RACU (Ethernet)
Compatible with XDS Control Center software
Very suitabe in▫ Corporations: multi channel meeting rooms, flat and curved
screens
▫ Automotive, Oil & Gas, Scientific research:3D visualization
▫ Theme parks
MCM-100S4
13jun133
Identification of the main parts (1)
MCM-100S5
Diagnostic LEDsDiagnostic LEDs
Mount bracketsMount brackets
IR receiverIR receiver
Identification of the main parts (2)
MCM-100S6
Description
A Desktop input
B Source inputs
C Stereo sync inputs
D Stereo syncoutputs
E Network
F Output connector
G Power connector
H Fuse
13jun134
Identification of the main parts (3)
MCM-100S7
Power supplyPower supply
Remote Control UnitRemote Control Unit
Power cordPower cord
Powering the system ON and OFF (1)
Powering ON1. Connect the power supply
to the MCM-100S
2. Connet the power cord to the power supply
3. Connect the power cord to the wall outlet.
4. Wait for the unit to come to active mode (ON).
MCM-100S8
13jun135
Powering the system ON and OFF (2)
Switching OFFi.e. switching from Active mode to Standby mode
1. In Active mode, press the on/off key for 3 seconds.
2. The “ON” LED turns off and the “STANDBY” LED turns on.
MCM-100S9
Powering the system ON and OFF (3)
Switching ONi.e. switching from Standby mode to Active mode
1. In Standby mode, press the on/off key for 1 second.
2. The “STANDBY” LED turns off and the “ON” LED turns on.
MCM-100S10
13jun136
Powering the system ON and OFF (4)
Powering OFF1. Switch off the MCM-100S
2. Disconnect the power cord from the wall outlet.
MCM-100S11
Connections Additional information▫ Desktop IN: see XDS
Displays training
▫ DVI connectors do not support analog signals
▫ SL-DVI and DL-DVI available
▫ RGB data: RGBHV, RGsB, RGBCs, YUV
▫ DVI out is HDTV or WUXGA
▫ Stereo sync out: stereo emitter and/or synchronization
MCM-100S12
13jun137
On Screen Display (OSD) or ‘Menu’ (1)
In the ‘Menu’▫ “<Main menu item>”: press the down arrow
key on the RCU to open the drop down menu (e.g. General)
▫ “<Text>...” :a new dialog box or edit box opens when selecting and confirming this item (e.g. Identification...)
▫ “<Text> ►”: press the right arrow key on the RCU to open the drop down menu (e.g. Desktop ►)
MCM-100S13
On Screen Display (OSD) or ‘Menu’ (2)
In edit boxes of the ‘Menu’▫ Select the edit field and confirm
▫ Use arrow keys ◄ and ►to select the character to be changed
▫ Use arrow keys ▲ and ▼ to change the selected character, orUse the keys 0..9 to enter a digit
MCM-100S14
13jun138
Basic operations (1)
MCM-100S15
Setting the RCU address▫ Common MCM-100S IR
address is “0” by default
Setting the MCM-100S IR address
Basic operations (2)
MCM-100S16
Selecting a source via RCU
Selecting a source via menu
13jun139
Basic operations (3)
MCM-100S17
Aligning a source on the screen
, or perform a Limited or Full scan(full scan can take more than two minutes)
Basic operations (4)
MCM-100S18
Pause - Resume
Freeze - Unfreeze
13jun1310
Basic operations (5)
MCM-100S19
Image settings: do not change in multi-channel systems!
Basic operations (6)
MCM-100S20
Changing color temperature▫ In multi channel systems, this will lead to bad color uniformity!
▫ If colors have been aligned during installation, return to those settings by enabling Dynacolor (see next slide)
13jun1311
Basic operations (7)
MCM-100S21
Enabling defined color correction (Dynacolor)▫ Enabling Dynacolor only makes sense if colors have been
calibrated and/or aligned during installation
▫ In multi channel systems, Dynacolor should always be enabled!
Maintenance (1)
First use▫ Check device and cables on damage
Weekly maintenance▫ Check device and cables on damage: repair or replace
damaged items
▫ Display test patterns and check the projected image
MCM-100S22
13jun1312
Maintenance (2)
Monthly maintenance▫ Vacuum clean air inlet grids in dusty environment
Yearly maintenance▫ Clean the device
MCM-100S23
Maintenance (3)
MCM-100S24
Condition based maintenance▫ Make a backup each time settings are changed
▫ Upgrade the firmware if needed
▫ Replace the batteries of the RCU
13jun1313
Warnings
Message Description
No signal Source signal not available: check source, cables
Desktop resolution not valid
Source signal on XDS Desktop input is not WUXGA@60Hz: check source, cables
Wait box Processing is ongoing: wait
MCM-100S25
Limitations and restrictions
10°C – 50°F < Operational temperature < 40°C – 104°F
MCM-100S26
13jun1314
Diagnostics
Diagnostic LEDs
MCM-100S27
LED/ status Nopower
Standby mode Configuring Active mode IR activity
Hardware error
STANDBY (red) OFF ON ON OFF NA NA
ON (green) OFF OFF ON ON NA NA
ERROR (red) OFF OFF OFF OFF NA ON
IR (green) OFF ON (network ok)OFF (no network)
ON ON (network ok)OFF (no network)
BLINKING NA
List of available documentation
Basic user
▫ User guide: R5905187
▫ Safety manual: R5905189
▫ WEEE Recycling passport: R59770743
Advanced user / administrator▫ API command set:
R5905497
MCM-100S28
13jun1315
Who to contact in case of problems (1)
First line help:
▫ Contact a certified MCM-100S specialist in your company
Escalation flow:
▫ Contact your local Barco Partner or Integrator
▫ Contact Barco support:www.barco.com Training & Support > Support
MCM-100S29
Who to contact in case of problems (2)
Make sure to have the following information available:
▫ Device identification
▫ Diagnostics information
MCM-100S30
13jun1316
www.twitter.com/Barco
www.facebook.com/Barco
www.youtube.com/BarcoTV