DESCRIPTION
Variable Rate Fertilizer at Reduced Scales. Randy Taylor Biosystems and Agricultural Engineering Oklahoma State University. 2010 NUE Conference Stillwater, OK. Field Scale Variability. Macro-variability Likely tied to soil type, landscape position, or something else Micro-variability. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Variable Rate Fertilizer at Reduced Scales](https://reader036.vdocuments.net/reader036/viewer/2022062520/568161e6550346895dd208ef/html5/thumbnails/1.jpg)
OSU
Pre
cisi
on S
ensi
ng
Variable Rate Fertilizer at Reduced Scales
Randy TaylorBiosystems and Agricultural Engineering
Oklahoma State University
2010 NUE ConferenceStillwater, OK
![Page 2: Variable Rate Fertilizer at Reduced Scales](https://reader036.vdocuments.net/reader036/viewer/2022062520/568161e6550346895dd208ef/html5/thumbnails/2.jpg)
OSU
Pre
cisi
on S
ensi
ng
Field Scale Variability
• Macro-variability– Likely tied to soil type, landscape position, or
something else• Micro-variability
0
2
4
6
8
10
12
14
16
18
App
licat
ion
Rat
e, g
pa
RX_RATERATE
![Page 3: Variable Rate Fertilizer at Reduced Scales](https://reader036.vdocuments.net/reader036/viewer/2022062520/568161e6550346895dd208ef/html5/thumbnails/3.jpg)
OSU
Pre
cisi
on S
ensi
ng
Variability View from Equipment
• Longitudinal– Down-the-row– Response time issues
• Lateral– Across the boom– Boom divisions
A greater distance between the control and delivery points means a lower resolution and increased scale.
![Page 4: Variable Rate Fertilizer at Reduced Scales](https://reader036.vdocuments.net/reader036/viewer/2022062520/568161e6550346895dd208ef/html5/thumbnails/4.jpg)
OSU
Pre
cisi
on S
ensi
ngSub-Meter Application System is a Proven Concept
![Page 5: Variable Rate Fertilizer at Reduced Scales](https://reader036.vdocuments.net/reader036/viewer/2022062520/568161e6550346895dd208ef/html5/thumbnails/5.jpg)
OSU
Pre
cisi
on S
ensi
ng
Liquid Systems
• The initial sub-meter application system met market resistance
• However, sensor based VRA has found commercial success
• Section control systems have also renewed the interest in sub-boom width application
![Page 6: Variable Rate Fertilizer at Reduced Scales](https://reader036.vdocuments.net/reader036/viewer/2022062520/568161e6550346895dd208ef/html5/thumbnails/6.jpg)
OSU
Pre
cisi
on S
ensi
ng
Accepted Resolution
0
2
4
6
8
10
12
14
0 20 40 60 80 100
Min
imum
Res
pons
e Tim
e, s
Application Scale, ft
5 mph10 mph15 mphLimit
![Page 7: Variable Rate Fertilizer at Reduced Scales](https://reader036.vdocuments.net/reader036/viewer/2022062520/568161e6550346895dd208ef/html5/thumbnails/7.jpg)
OSU
Pre
cisi
on S
ensi
ng
Reduced Scale
0.0
0.5
1.0
1.5
2.0
2.5
3.0
0 5 10 15 20
Min
imum
Res
pons
e Tim
e, s
Application Scale, ft
5 mph10 mph15 mphLimitLimit
![Page 8: Variable Rate Fertilizer at Reduced Scales](https://reader036.vdocuments.net/reader036/viewer/2022062520/568161e6550346895dd208ef/html5/thumbnails/8.jpg)
OSU
Pre
cisi
on S
ensi
ng
Liquid Systems
• Most commercial rate controllers can be set to about a 2 second response time.
• Multiple control sections will require multiple control valves and possibly flow meters.
• Pulse width modulation and binary valve systems have promise.
![Page 9: Variable Rate Fertilizer at Reduced Scales](https://reader036.vdocuments.net/reader036/viewer/2022062520/568161e6550346895dd208ef/html5/thumbnails/9.jpg)
OSU
Pre
cisi
on S
ensi
ng
Granular VRT
• Granular distribution/delivery systems follow two basic designs– Gate/belt or chain/spinner– Metering wheel/air boom
• While both systems can be used for variable rate application, reducing the application scale to a partially width is really not feasible
![Page 10: Variable Rate Fertilizer at Reduced Scales](https://reader036.vdocuments.net/reader036/viewer/2022062520/568161e6550346895dd208ef/html5/thumbnails/10.jpg)
OSU
Pre
cisi
on S
ensi
ng
Spinner Spreaders• Reducing application scales
with spinner spreaders is really not feasible.
• The material is centrally metered and distributed.
• Furthermore, VRA with spinner spreaders is a challenge.– Spread distribution patterns
are typically a function of flow rate onto the spinner
![Page 11: Variable Rate Fertilizer at Reduced Scales](https://reader036.vdocuments.net/reader036/viewer/2022062520/568161e6550346895dd208ef/html5/thumbnails/11.jpg)
OSU
Pre
cisi
on S
ensi
ng
Air Boom Systems
• The material is centrally metered, but patterns are created locally.
• The primary challenge is lag time from the metering system to the point of application
![Page 12: Variable Rate Fertilizer at Reduced Scales](https://reader036.vdocuments.net/reader036/viewer/2022062520/568161e6550346895dd208ef/html5/thumbnails/12.jpg)
OSU
Pre
cisi
on S
ensi
ng
Potential Solutions
• The central hopper/conveying system might be a good model to follow
![Page 13: Variable Rate Fertilizer at Reduced Scales](https://reader036.vdocuments.net/reader036/viewer/2022062520/568161e6550346895dd208ef/html5/thumbnails/13.jpg)
OSU
Pre
cisi
on S
ensi
ng
Section Control System Speed
![Page 14: Variable Rate Fertilizer at Reduced Scales](https://reader036.vdocuments.net/reader036/viewer/2022062520/568161e6550346895dd208ef/html5/thumbnails/14.jpg)
OSU
Pre
cisi
on S
ensi
ng
Rate Controllers and Tuning
0
2
4
6
8
10
12
14
0.0 0.2 0.4 0.6 0.8 1.0NDVI
Pres
crip
tion,
GPA 1 gpa/0.05 NDVI
2.5 gpa/0.05 NDVI
0
2
4
6
8
10
12
14
16
18
App
licat
ion
Rat
e, G
PA
RX_RATERATE
• Prescriptions should not be developed without considering rate controller performance.
• Worry about the macro variability within the field.
• Are you capturing the general trend?