Energy-efficient Dynamic Capacity Provisioning in Server Farms VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

Upload: aliza-jolles

Post on 01-Apr-2015

219 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

Energy-efficient Dynamic Capacity Provisioning in Server Farms

VARUN GUPTACarnegie Mellon University

1

Partly based on joint work with:

Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

Page 2: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

2

The “provisioning for peak” problem

Demand(t)

Time (t)

?

Data CenterCapacity

PROBLEM: Want to turn servers OFF/ON to match (t)…

… and also minimize setup penalties!

Page 3: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

3

First Attempt: ON/OFF policy

0 2 4 6 8 10 120

50

100

150

200

250r(t)#Busy servers

Time (hrs)

(t)# Busy servers# Jobs

Mean Job Size = 1sSetup delay = 200sBusy power = 240W

Page 4: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

4

First Attempt: ON/OFF policy

0 2 4 6 8 10 120

50

100

150

200

250r(t)#Busy servers

Time (hrs)

(t)# Busy servers# Jobs

Mean Job Size = 1sSetup delay = 200sBusy power = 240W

Page 5: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

5

First Attempt: ON/OFF policy

0 2 4 6 8 10 120

50

100

150

200

250r(t)#Busy servers

Time (hrs)

(t)# Busy servers# Jobs

Mean Job Size = 1sSetup delay = 200sBusy power = 240W

Page 6: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

6

First Attempt: ON/OFF policy

0 2 4 6 8 10 120

50

100

150

200

250r(t)#Busy servers

Time (hrs)

(t)# Busy servers# Jobs

Mean Job Size = 1sSetup delay = 200sBusy power = 240W

WITH SETUP: E[Power] = 51.9 kW E[Response time] = 13s

NO SETUP: E[Power] = 14.4 kW E[Response time] = 1s

Page 7: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

7

First Attempt: ON/OFF policy

0 2 4 6 8 10 120

50

100

150

200

250r(t)#Busy servers

Time (hrs)

(t)# Busy servers# Jobs

Mean Job Size = 1sSetup delay = 200sBusy power = 240WCan we do better than ON/OFF? .

Add inertia while turning servers OFF

Page 8: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

8

Our Prescription: DELAYEDOFF

Turn OFF a server after idle for twait

twait independent of (t)!

new arrival routed to themost recently busy (MRB) server

arriving job turns a server ONif all servers busy

Page 9: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

9

twait timers

Page 10: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

10

twait timers

Page 11: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

11

twait timers

Page 12: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

12

Our Prescription: DELAYEDOFF

THEOREM: For Poisson arrivals, as the load , the number of ON servers is concentrated around

--- Proof Intuition ---

Step 1: An equivalent system view

k jobs run on the “first” k servers

Step 2: Analysis of idle periods of M/G/∞

Time from a k(k-1) to the next (k-1)k transition

Page 13: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

13

Intuition for idle periods

1. # jobs Normal with mean and variance

2.

3. Events happen at rate

4. Mean idle period of server

1

2

3

MRB servers for any constant twait !

In practice, we choose twait to amortize setup cost

Page 14: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

14

0 2 4 6 8 10 120

50

100

150

200

250

r(t)#Busy servers

Time (hrs)

0 2 4 6 8 10 120

50

100

150

200

250

Time (hrs)

Mean Job Size = 1sSetup delay = 200sBusy power = 240W

(t)# Busy+idle servers# Jobs

ON/OFF

DELAYEDOFF

Page 15: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

15

0 2 4 6 8 10 120

50

100

150

200

250

r(t)#Busy servers

Time (hrs)

0 2 4 6 8 10 120

50

100

150

200

250

Time (hrs)

Mean Job Size = 1sSetup delay = 200sBusy power = 240W

(t)# Busy+idle servers# Jobs

ON/OFF

DELAYEDOFF

Page 16: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

16

0 2 4 6 8 10 120

50

100

150

200

250

r(t)#Busy servers

Time (hrs)

0 2 4 6 8 10 120

50

100

150

200

250

Time (hrs)

Mean Job Size = 1sSetup delay = 200sBusy power = 240W

(t)# Busy+idle servers# Jobs

ON/OFF

DELAYEDOFF

DELAYEDOFF: E[Power] = 18.9 kW E[Response time] = 1.002s

NO SETUP: E[Power] = 14.4 kW E[Response time] = 1s .

Page 17: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

17

0 2 4 6 8 10 120

50

100

150

200

r(t)#Busy servers

Time (hrs)

0 2 4 6 8 10 120

50

100

150

200

Time (hrs)

Mean Job Size = 1sSetup delay = 200sBusy power = 240W

(t)# Busy+idle servers# Jobs

DELAYEDOFF

SQ. ROOT W/LOOKAHEAD

(“optimal offline”)

Page 18: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

18

0 2 4 6 8 10 120

50

100

150

200

r(t)#Busy servers

Time (hrs)

0 2 4 6 8 10 120

50

100

150

200

Time (hrs)

Mean Job Size = 1sSetup delay = 200sBusy power = 240W

(t)# Busy+idle servers# Jobs

DELAYEDOFF

SQ. ROOT W/LOOKAHEAD

(“optimal offline”)

Page 19: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

19

0 2 4 6 8 10 120

50

100

150

200

r(t)#Busy servers

Time (hrs)

0 2 4 6 8 10 120

50

100

150

200

Time (hrs)

Mean Job Size = 1sSetup delay = 200sBusy power = 240W

(t)# Busy+idle servers# Jobs

DELAYEDOFF

DELAYEDOFF: E[Power] = 18.9 kW E[Response time] = 1.002s w/LOOKAHEAD: E[Power] = 15.8 kW E[Response time] = 1.036s

SQ. ROOT W/LOOKAHEAD

(“optimal offline”)

Page 20: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

DELAYEDOFF mods

1. Speed scaling algorithms2. A simple proxy for MRB routing3. Heterogeneous servers4. Managing Virtual Machines in the Cloud5. Wear-leveling/Performance tradeoffs

20

Page 21: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

21

Effect of DELAYEDOFF on speed-scaling

PowerP(s)

Speed (s)

Q: Optimal speed to balance energy-performance?

A: your favorite metric =

Page 22: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

22

A simple proxy for MRB routing

MRB requires a lot of state updates

Proxy policy• Assign static ranks to servers• Route a new arrival to highest ranked idle server

Almost the same performance as MRB+ easier to implement than MRB+ easy to extend

(MRB)

Rank

1

2

3

4

5

Rank-based

Page 23: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

23

DELAYEDOFF for heterogeneous servers

more efficient

less efficient

Assign ranks to servers based on efficiency (1 = most efficient)

Route a new arrival to highest ranked idle server

1

2

3

4

5

Page 24: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

24

Managing Virtual Machines in the Cloud

2GB RAM

2GB RAM

2GB RAM

1GB

1GB

1GB

Page 25: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

25

Managing Virtual Machines in the Cloud

1

2

3

4

5

6Split physical servers into “virtual” servers

Assign static ranks to virtual servers

Route a new VM request to highest ranked idle virtual server

Turn the physical server OFF after each virtual server has idled for twait

Page 26: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

Conclusions Problem: unpredictable

demand and non-trivial setup costs

DELAYEDOFF : A new traffic-oblivious capacity scaling scheme

Extensions to real-world scenarios

26

Time (hrs)

Demand

?Time

MaxCapacity

Page 27: VARUN GUPTA Carnegie Mellon University 1 Partly based on joint work with: Anshul Gandhi Mor Harchol-Balter Mike Kozuch (CMU) (CMU) (Intel Research)

27

The Importance of Being MRB

THEOREM [MRB]: As the load , the number of ON servers is concentrated around

THEOREM [Round-Robin]: As the load , for constant

job sizes, the number of ON servers is

N serversArrival rate = λ