ventilation.pdf
DESCRIPTION
OutfittingsTRANSCRIPT
-
Marin
An oAir terang
The provimachthe cthe s
Type
Thernaturtempscoo
Mostperfo
The
abc-
neOutfittings
ocean-goingemperaturee from 0oC
air from thide an accehinery use cargo. The ships trade
es of Syste
re are two bral ventilatperature anops towards
t modern ormance an
mechanica
- Mechani- Mechani- Mechani
s
g ship is reqes may rang
to 38oC. T
he air-condeptable climand to maidesign of sroutes, typ
ems
basic typestion system
nd density os the wind.
ships utilnd the reduc
l ventilation
cal-supply /cal- exhauscal-supply /
Ven
quired to oge from -15he moisture
itioning anmate for thintain temp
suitable syspes of cargo
s of ventilatm, air moof inside an
ize mechaced size of
n system m
/ natural-exst / natural-/ mechanic
ntilation
perate in a
5oC to 50oCe content o
d ventilatioe crew to
perature andstems will tho and mach
tion systemovement isnd outside
anical vencowls nece
ay be eithe
xhaust type- supply typcal- exhaust
n
a variety of and sea w
of the air wil
on plants islive and wod humidity herefore reqhinery insta
ms; natural as created
air and the
ntilation foressary.
er:
e, or pe, or t type
Prof.Dr.
very differewater tempe
l vary cons
s therefore ork in, suffat acceptaquire informllation.
and mechaby the d
e trimming
r reliability
YousriWelay
ent climateseratures masiderably.
required tficient air foble levels t
mation abou
anical. In thifference iof cowls o
y, improve
ya
s. ay
to or to ut
he in or
ed
-
Marin
Depe(a) wmainis usmigheitheon th
Mechsystesupp
The can blow o
The admiinsulof the
neOutfittings
ending upowill maintainntain a slighsed in spaceht dispel ther a slight phe relative r
hanical venem uses aplied along t
air is drawnbe reversedoutside air t
closed sysitted. The vating wall oe hold.
s
n the locatin a slight poht negative es such as e heat and
positive or nratings of th
ntilation canaxial flow fatrunking an
n from the d if condentemperature
stem recircuventilation aor curtain b
ion of the faositive prespressure wgalleys, to
d odors intonegative prhe supply a
n also be claans fitted i
nd ducts to t
top of the hsation is like.
ulates air aair is distribbetween the
2
an or fans wssure withinwithin the silets, and po adjacent ressure witnd exhaust
assified as in the inletthe bottom
hold just bekely near th
and a contrbuted aroune two. Exha
within the sn the spacepace serve
pantries whe spaces. T
hin the spat fans.
open or clot and exhaof the hold
elow the dehe deck hea
rolled amound the hold aust air is d
Prof.Dr.
system. In ges served. Ted. This typere a positiType (c) maces served
osed systemaust trunksd.
ecks. The eads, for exa
unt of freshand cargo
drawn from
YousriWelay
general typType (b) w
pe of systemive pressur
may producd dependin
m. The ope. The air i
exhaust fanample with
h air can b, forming a
m the bottom
ya
pe ill m re ce ng
en is
ns a
be an m
-
3
MarineOutfittings Prof.Dr.YousriWelaya
Ventilation of Refrigerated Cargo Holds
These require a carefully controlled air-replacing system for each individual space. Cooled air is supplied to the refrigerated hold where it gains heat from ripening cargoes and entrains the gases produced. This air is then exhausted and a careful balance must be maintained between inlet and exhaust gas quantities, regardless of the outside climatic conditions.
In figure this is achieved by drawing outside air down to a bank of cooler tubes via a central unit. The dehumidified air then passes into the cargo holds. The exhaust gases are drawn from the hold through ducts to the central unit and then returned to the outside atmosphere.
-
Marin
Mach
The combthe o
Certaas looccuI.C.EVentspacdifficuncoand provi
Variothe fi
neOutfittings
hinery Spa
machinerybustion engoperating st
ain machinow temperaurring in theE. Over pretilation is alce and thuscult task isooled air to
control roided with an
ous systemigure.
s
aces
y space regines, comptaff to work
ery consumature as pre machineressure mayso necessa
s provide as achieved as many re
ooms, beinn acceptab
ms of air su
equires anpressors, ein.
mes or requactically pory space wy lead to leary to remo
a reasonablby the pr
egions as pg small, m
ble working
pply to the
4
n air supptc., and to
uires air forossible showill affect theakage of ove the heale climate frovision of
possible. Pamay be aiclimate.
e machinery
ly for the maintain a
r its operatiould be prohe efficienchot air into
at generatefor the staff ducted sarticular arer condition
y space an
Prof.Dr.
operation satisfactory
ion and sufovided. Undcy and perfo the acco
ed within theff to work iupplies of eas such asned and m
nd casing a
YousriWelay
of boilersy climate fo
fficient air ader pressurformance o
ommodatione machinern. This verfiltered bu
s workshopmore readil
are shown i
ya
s, or
at re of n. ry ry ut ps ly
in
-
Marin
(a)vepre
Figurtrunkexhafan tprovimedivario
Doub
neOutfittings
) Machineryentilation usingessure axial f
re (a) utiliking, whichausts througto supply ides air thrium pressu
ous outlets a
ble-Bottom
s
y space g medium flow fan
zes a medh is proporgh the top oair into therough ducture axial float the vario
m Tanks
(b) Maventilationaxial flowpressure
dium pressrtionally reof the casine casing as to outletsow fans to
ous platform
5
chinery spacen using low p
w fan and highcentrifugal fa
sure axial leased at ng. Figure (area. Also s at the va
o provide ams. This me
e
pressure h an
flow fan the variou
(b) uses a a high pr
arious platfa through tethod has p
Prof.Dr.
(c) Machineventilation uspressure axiathrough trunk
supplying us platformlow pressuressure cenforms. Figutrunking syroved to be
YousriWelay
ery space sing medium al flow fans anking system
air down levels anre axial flowntrifugal faure (c) useystem to the the best.
ya
nd a
a d w
an es e
-
6
MarineOutfittings Prof.Dr.YousriWelaya
Ventilation of double-bottom tanks is provided by means of an air pipe situated remote from the filling pipe and usually at the highest point in the tank to avoid unventilated pockets. The air pipe is led up to the weather deck to a gooseneck or patent type of head. Air pipes from fuel tanks are positioned in low risk areas and have flame screen gauzes fitted (see figure).
Cargo Tanks
Ventilation of cargo tanks avoid overpressure or partial pressure conditions which could occur during loading and unloading of cargo. Temperature fluctuations during a voyage could have a similar effect. Vapor pipelines from the cargo hatch are led to pressure/vacuum relief valves which are usually mounted on a standpipe some distance above the deck. Individual vent lines are fitted for each tank on large tankers and a common venting line is led up a mast or Sampson post on smaller vessels.
Design Criteria
The criteria include the recommended ventilation system, the temperature rise which is the maximum difference between exhaust air and supply air temperature (6oC for the galley and toilets), and the maximum air change which is the time in minutes for the supply of a quantity of air equal to the space volume (2 for the battery room, 10 for the emergency generator room, 1 for the galley, 4 for the toilets and showers).
In designing a ventilation system, the aim of the designer should be to run the duct in as nearly a straight line as possible, avoiding sharp bends, abrupt changes in duct sizes or shapes to minimize excessive pressure losses. Cross-sectional areas of ducts should be large enough to permit the air to flow at moderate velocities to avoid power waste and to reduce noise. Maximum duct velocity of 10 m/sec for areas where quiet operation is essential and 18 m/sec for areas where quiet operation is not essential, are good values.
When smaller ducts are taken off the main supply duct to serve individual spaces, the air quantity is divided in proportion to the area of the duct.
Construction Details
Ducts may be constructed of galvanizes sheet steel in order to withstand corrosion and vibration, or ducts may be constructed of aluminum in order to save topside weight. Vertical and horizontal ducts in general cargo holds are usually constructed of 6.5 mm and 4.8 mm plates respectively.
Because of headroom requirements, most ducts are rectangular; round ducts being used only in the smaller sizes. Usually a heavy section of ductwork is
-
7
MarineOutfittings Prof.Dr.YousriWelaya
welded into the penetrated structure where structural compensation is required. Hand holes, access holes, and portable sections are provided to permit cleaning, painting, and inspection. Ducts passing over electrical equipment are made watertight. Ducts are made with either riveted, welded, or hook seams and are airtight.
To maintain habitable temperature in machinery spaces and for the removal of fumes, spot cooling with large quantities of air at high terminal velocities, 13-15 m/s, is used at operating stations and other strategic locations. Exhaust terminals should be located in the vicinity of heat-producing equipment, and on the upper levels of the machinery space.
Ventilation Components
a) Types of Fans
Axial flow fans are used widely because of compactness and high efficiency and are well adapted for ventilation of cargo spaces, machinery spaces and other spaces where noise is not a significant consideration. Centrifugal fans are used for ventilation where quiet operation is desired and also for galleys, battery room exhaust, and areas where explosive vapors are removed, where the motor is not to be located in the air stream. Propeller fans are used in bulkhead installations and sometimes in a cowl for machinery space supply and exhaust systems where the pressure is small.
b) Weather-Terminal Openings
-
8
MarineOutfittings Prof.Dr.YousriWelaya
These include cowls, goosenecks, mushrooms, louvers and air lift boxes on deck or in bulkheads. All of these devices are fitted with wire mesh for rat-proofing. Weather terminals should be so located that exhaust air or stack gasses do not contaminate supply air.
c) Interior Terminals
High velocity directional terminals are used in galleys, pantries, laundries, machinery spaces, and similar heat-producing spaces where spot cooling is desired. Slotted outlets may be used in front of galleys hoods and switchboards. Ceiling or wall type diffusers are used for ventilated living spaces, with terminal
-
9
MarineOutfittings Prof.Dr.YousriWelaya
velocities so as to provide diffusion and throw, without objectionable air movement and air noise in the space.
Terminals for holds and storerooms are merely open-ended ducts or a cut in the side of the duct fitted with wire-mesh screens for rat proofing.
d) Exhaust Terminals
These are located close to heat sources and are usually an open-ended duct covered with wire-mesh or grilles where appearance is important. Exhaust inlet velocities should be about 5-8 m/s in living spaces and up to 10 m/s in other places.
e) Dampers
They are sometimes used to control the volume of air delivered at terminals. Manually operated dampers must be provided on passenger ships at the weather opening in all ventilating systems to shut off the passage of air in the event f fire.
Automatic dampers are required in exhaust ducts over potential sources of fire in galleys and are required to operate by melting a fusible link.
Air Conditioning Systems
-
10
MarineOutfittings Prof.Dr.YousriWelaya
These are used to modify the outside fresh air to improve the ships interior environment by heating, cooling, dehumidifying, and contaminant removal processes. Air conditioning is used almost exclusively for living spaces and sometimes for spaces containing electronic equipment. Conditioning of the air is accomplished by a cooling medium of chilled water or Freon and a heating medium of steam, hot water or electricity.
Types of Systems
a) Combination heating and cooling systems. b) Cooling systems. c) Dehumidification: for preventing moisture damage or condensation of
moisture on cargo and internal structures of all those portions of holds suitable for carrying dry cargo.
Design Criteria
Shipboard air conditioning systems are usually designed to maintain inside air temperatures ranging from 24oC to 29oC dry bulb, and a relative humidity of 50% with an outside air temperature of 35oC dry bulb and 28oC wet bulb during the summer season and inside air temperature of 21oC dry bulb with an outside temperature of -18oC dry bulb during the winter season.
The criteria for cargo hold dehumidification is normally to maintain the dew-point of atmosphere within the hold at a minimum design depression of 6oC dew-point below the surface temperature of the cargo or ships structure.