· web viewassam agricultural university. jorhat-785013. bidding document (terms and conditions)...

63
ASSAM AGRICULTURAL UNIVERSITY Jorhat-785013 BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A)/30226-34 Dtd: 04.02.2017. Directorate of Research ASSAM AGRICULTURAL UNIVERSITY Jorhat-785013

Upload: duongkiet

Post on 26-Apr-2018

217 views

Category:

Documents


3 download

TRANSCRIPT

Page 1:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

ASSAM AGRICULTURAL UNIVERSITYJorhat-785013

BIDDING DOCUMENT (Terms and conditions)

2-1 (41.3) /2009-10 /DRA (A)/30226-34 Dtd: 04.02.2017.

Directorate of ResearchASSAM AGRICULTURAL UNIVERSITY

Jorhat-785013

Page 2:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

Terms and Conditions

1. The quotation fees of Rs.200/- (Rupees Two hundred only) in favour of Director of Research (Agri.), AAU, Jorhat is not refundable. Those who will submit the quotation by down loading the tender documents,they must have to submit the quotation fee in the form of DD along with the quotation without which quotation will be rejected

2. The bidder shall enclose EMD 2% of the quoted price in the shape of DD drawn in favour of the Director of Research (Agri.) AAU, Jorhat The bids that are not accompanied by the aforesaid bid security will not be accepted. The details of bid security must be provided. The bid security of the unsuccessful bidders will be released after issuing supply to the successful bidder and the bid security of the successful bidder will be released after execution of the order.

3. The quotation shall be sealed and super scribed at the top of sealed cover “Quotation for Lab equipments invited vide memo no. No. 2-1(41.3)/2009-10/DRA(A)/ 30226-34 Dtd. 04.02.2017

4. Quoted price: To facilitate format evaluation, the bidder shall quote the price of items separately along with relevant papers for supporting the quoted price such as catalogue, dealership certificate and Co’s printed price list, user list etc. failing which the bid shall be treated as non-responsive at the discretion of the purchaser.

5. The bid submitted to the bidder shall remain valid for a period of 90(ninety) days. Bid not conforming to this provision shall be treated as non-responsive.

6. To facilitate prompt evaluation, the bidder shall provide Technical Compliance Report (TCR) and price data for each item separately.

7. Quotation must also be submitted in a soft copy in CD (to support in Microsoft words only) in the following format failing which the bid treated as non-responsive, at the discretions of the purchaser. In case of any optional items, pictures should be shown separately. Any discrepancies in the soft copy will be the responsibility of the quotioners.

Format

Page 3:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

Name of Item Brief Specification

Unit Price VAT/CST/Freight Charge if any (FOR Jorhat)/2% Entry

tax (where applicable) etc

Total

8. The rate shall be quoted for all duties, taxes and other levies payable by the bidder(other than VAT) shall be included in the item rate. VAT should be quoted separately(TIN No. must be furnished)

9. Bidders from outside Assam may include 2% Entry tax on the Unit price in the Quotation.

10. There should not be any overwriting. Corrections, if any, should be made with dated initial of bidder. Bidder shall submit quotation separately in each item.

11. Rates should be quoted clearly both in words and figures separately for each item without which the quotation shall stand rejected.

12. The price quoted shall be fixed and not subject to adjustment/variation during the performance of the contract.

13. The warranty of the items shall be as per the prevailing warranty policy/certificate of manufacturer (where necessary) for the items and warranty period shall not be less than months from the date of commissioning of items at site.

14. The bidder shall furnish the warranty for all the items at the time of delivery and commissioning. The purchaser shall reject the items not enclosed by warranty certificate from their manufacturer. The warranty certificate should be duly signed and sealed.

15. Bidders must supply the items at their own cost. All machineries/equipments are to be supplied FOR destination. Delivery of goods shall have to be completed within 30 (thirty) days from the date of issuing supply order.

16. Installation and commissioning charges, it any, inclusive of expenses of foundation work etc. are to be mentioned separately against each machine. In case of no mention, the same will be considered as inclusive of installation cost whenever applicable.

17. The machineries are to be supplied ready to operate, complete with motor, starter and any necessary gadgets including catalogues, trouble shooting manual etc. without which the same will be considered as incomplete supply.

Page 4:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

18. List of spare parts with current price to be required during operation of the machines and addresses of the source of spare parts availability including contact no., e-mail etc. are to be provided in a separate sheet.

19. Price of one set of critical wearable spares that would hamper the working of the machineries/equipments should be mentioned separately against each machine.

20. The supplier shall provide free maintenance services during the period of warranty. Any repair and maintenance including providing of spare parts (covered by manufacturer’s warranty certificate) during the warranty period shall be bidder’s responsibility.

21. Detailed specification with make, model, size, and code no., catalogue, and name of manufacturer should be furnished. ISO certificate must be furnished for the offer make where applicable.

22. Copies of S.S.I registration or such documents may be produced with quotation.

23. Attested copies of dealership certificate and Co’s printed price list must be enclosed with the quotation.

24. Up-to-date sale Tax clearance certificate and Income Tax return of last two years duly attested must be submitted along with the quotation. PAN No. must be furnished.

25. All payment shall be made preferably in Indian Rupees only.

26. Where ever the laws and regulations require, deduction of taxes at source of payment, the purchaser shall effect such deduction from the payment due the supplier, the remittance of amounts so deducted and insurance certificate for such deduction shall be made by the purchaser as per the laws and regulation in force.

27. The quotation will be opened on the day of last date of submission at 1 p.m. in the office of the undersigned, AAU, Jorhat-13. The bidder or his authorized representative may attend the bid opening. Except price, no other details will be announced during the opening.

28. Every page of the bidding documents purchased from the purchaser are to be signed by the bidder including their acceptance of terms and conditions and returned with their quotation.

29. The undersigned reserves the right to accept or reject any quotation and to cancel the instant bidding process and reject all quotation at any

Page 5:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

time prior to award of contact, without thereby incurring any obligation to the affected bidders of grounds for the purchaser action.

Page 6:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

ANNEXURE –IFormat for EMD Details

Sl.No Sl. No of the item (as per bid document)

Name of the item quoted

Basic price of the item (excluding taxes and transportation charges)

Price in Indian rupee ( for imported items at the prevailing rate of exchange)

Amount of EMD (2% of basic price)

Details of EMD submitted including amount and validity

ANNEXURE – IIFormat for Technical Compliance Report & Price Data

1. Sl. No of the item (as per bid document)2. Name of the item:3. Name of scheme:

Sl.No Specification asked for ( strictly as mentioned in bid document)

Specification offered (Corresponding to specification in bid document)

Technical compliance (Yes / No)

Variation if any Technical literature supporting the technical compliance (Suitably tagged)

FORMAT FOR QUOTATION(Separate Quotation for individual items to be submitted)

Sl. No Name of the item (s) Brief Specification

Unit price % of VAT / TAX / Freight

Total amount

Page 7:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

charge/2% Entry tax etc.

We agree to supply the above items in accordance with the technical specification mentioned. We also confirm that normal commercial warranty / guarantee of ………….months shall apply to the offered goods.

Quotationers Name : Signature

Date: Seal

Page 8:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

Sl. No

Name of the Project

Name of Equipmen

tsSpecification

1. AICRP on Farm Implement and Machinery, AAU, Jorhat

Tractor with accessories

A. Tractor: i). Type : Agricultural tractor with 55-60 Engine HP,

power steering with cage wheel, standard tools and accessories

ii). CMVR certifiediii). Tested at CFMTTI, Budni, MPiv). 4 WD desirable

B. Accessoriesi). Trailer: Two wheel semi low bed double drop down

type non tipping trailer of mild steel with provision of spring leaf and hitching arrangement, Capacity 2-3 ton, MS sheet thickness sides 2.5 mm or more, bottom 4 mm or more, Hydraulic system as per AIS:043-2005

ii). Reversible Plough- 2- Furrow, Weight-not less than 339kg, Depth of furrow-150-200 mm

Matching Ballast Weight, Canopy, Canopy Holder, Tow Hook, Wagon Hitch, Drawbar

2. AICRP on Farm Implement and Machinery, AAU, Jorhat

Sub soiler Tractor power 45-55 HP

No. of tynes 1

No. of shank position 1

Working depth 610 mm

Working width 70 mm

Tyne size 152 X 36 mm

Frame size 254 X90X926 mm

Weight 120 kg

3. AICRP on Farm Implement and Machinery, AAU, Jorhat

Tractor operated inter

row weeder

Tractor power 35 HP

Working width 1200 mm

Weeding blade rotary

Rotary number 2

Weight 400 kg

4. AICRP on Farm Tractor Tractor power 45 and Above

Page 9:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

Implement and Machinery, AAU, Jorhat

operated bund former

No. of discs 2

No. of shank position 1

Working depth 330 mm

Maximum width 1100 mm

Weight 210 kg

5. AICRP on Farm Implement and Machinery, AAU, Jorhat

Paddy transplanter

Walk behind type , L-3140mm, W- 2090mm, H-1860mm, Weight-648kgs, Fuel tank capacity-20L, 4 cycle air cooled, Dimensions (LWH)-3.14X2.09X1.86 M,, Field capacity- 0-16 m/sec

6. AICRP on Farm Implement and Machinery, AAU, Jorhat

Tractor operated

reaper

Tractor power 35 HP, minimum width of cut 120 cm

7. AICRP on Farm Implement and Machinery, AAU, Jorhat

Paddy transplanter walk behind

type

L-3140mm, W- 2090mm, H-1860mm, Weight-648kgs, Fuel tank capacity-20L, 4 cycle air cooled, Dimensions (LWH)-3.14X2.09X1.86 M, , Field capacity- 0-16 m/sec

8. AICRP on Farm Implement and Machinery, AAU, Jorhat

Mini reaper binder

Harvesting and binding of grains crops in single operation, Engine-10hp, Air cooled, Fuel consumption-=1 Lit, Gear-4F 1R, Cutting Width- 1.22m, L-360cm, Width-185 cm, Weight- 400 Kgs, Crops- Wheat, Paddy, Oats, Barely and other grain crops of height upto 85 to 110 cm, Field apacity-0.4 Ha/h

9. RARS, Diphu Xerox /copier machine

Memory-128 MB, Dimensions(mm): 1,020 x 565 x 678, Weight: 80 kg, Max Power consumption: 120 VAC, 60Hz, 15A, Max Paper size: A3, Copy/ print speed: 33ppm.

10. AICRP on Natural Fibre, BNCA

UV Vis Spectrophotome

ter

Measuring Principle : Single BeamLamp Type : Xenon FlagshipWavelength Range : 190-1100nmMeasuring modes : Concentration, Absorbance, % transmittance, Multi wave length, Scanning, KineticsWavelength Cal. : AutomaticMonochromator : Grating monochromator with step motor. 1200lines/nmMaximum Scanning speed : Approx. 3300 nm/minAccuracy : + 1nmReproducibility : + 0.5nm (Checkable with Holmium oxide Filters)Resolution : + 1 nmSpectral Bandwidth : 4nmLight Sensor : PhotodiodeMeasuring Range : A=-3.300

Page 10:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

Linearity : <1% for A< 2.000 in range of 340 to 900 nmAccuracy : - 0.003 for A < 0.600- 0.5% of reading for 0.600 < A < 2.000Reproducibility : + 0.002 at A= 1.000Resolution : ∆A = 0.001Stray Light : <0.1% transmission at 340nm & 409nmUSB – 1X USB A (For printer, USB storage medium, Barcode Reader, Keyboard)Weight : Approx. 3.7 kg without plug in power supplyBattery back up facility : option Available

11. AICRP on Natural Fibre, BNCA

Electronic Balance

Capacity : 220 gmsMinimum Display : 0.1 mgPan Size : 91Main body dimensions (mm) : 210(W)x 340(D)x325(H)Weight : 6.2 kgPower requirement : 12V, 1ATouch key calibration : internal

12. AICRP on Natural Fibre, BNCA

Soil moisture meter with accessories

Digital display of 1-100%Available soil moisture; High accuracy

13. AICRP on Natural Fibre, BNCA

Shaker Double Walled; Inner S.S. 304; Outer M.S. Powder Coated ;Microprocessor PID Digital Temp. Indicator-cum-Controller; Temp. ranges from Ambient to 60 ºC +/- 1 ºC; 2 Nos of SS Clamps of Each Size cap Flask 50,100, 250, 500 & 1000ml Flasks ( Total 10 Nos ) are provided ;Shaker has VARIABLE SPEED of 20-250 RPM; Orbit dia 25mm ; Universal Platform of 16”x 14” ; Work on 220V/230 volts. A.C. EXTRA SS Clamps of Any Size ( Please Mention Quantity & Size )

14. AICRP on Natural Fibre, BNCA

pH/conductivity/TDS/ salinity

meter

Range : 0.0 -99.9ppm/ 100-999ppm / 1.00 – 10.00ppt/ 0.0-1.00%Resolution : 0.1ppm/1ppm/0.01ppt / 0.01%Accuriacy : ± 1% full scale Cal. Point : 1(manual above 1.00ppt)TemperatureRange : 0-50.0° C / 32-122.0° FResolution : 0.1° C / 0.1° FAccuracy : 0.5° C / 0.9° FMeter features : Auto off 8.5Mins after last key pressed. Duel LCD display (2.1 x 2.7cm), Power 4 x 1.5V A76 micro alkaline battery. Tester dimension 16.5 x 3.8 cm: 90gm

15. AICRP on National Seed Project (Crops),AAU, Jorhat

Generator 30/40 KVA Silent Diesel Generator set, Starting system 12 volt DC self

16. AICRP on National Seed Project (Crops),AAU, Jorhat

Lyophilizer Capable of handling half of the total ice holding capacity for small tissues.  Temperature differential of 15–20˚ between the samples' freezing point and the collector chamber. Cascade -84˚C to freeze dry and effectively trap the solvents.  Control System :

Page 11:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

PC/PLC with Opti-Dry Software Shelf Temperature Range -48C or –70C to +65C ,Shelf Heat Transfer Hollow Fluid Filled, Shelf Size and Finish 10” x 18” , 316L, 20 Ra or better Shelf Area 3.75 sq ft Shelf Assembly Bulk or Stoppering ,Condenser Temperature -53C or –85C ,Condenser Capacity 8L,Condensing Rate 6L in 24 hours Condenser Style Exposed Coil Compressors Hermetic Defrost Hot Gas Vacuum Pump 200 LPM, Corrosion Resistant Vacuum Control Pirani w/Solenoid & Needle Valve Gas Backfill Included Product Sensors Four (4) Cabinet 35”W x 40”D x 52”H Electrical 230V/60Hz or 200V/50Hz, 1PH

17. AICRP on National Seed Project (Crops),AAU, Jorhat

Photocopier Print / Copy / Scan features; B / W Laser Multifunctional (Reader / Printer Console), Copy speed: A4 minimum 22ppm, A3 Minimum 11ppm, OS compatibility: Windows 8.1 / 8 / 7 / Vista / XP / 2000, Windows Server 2012 / Server 2008 / Server 2003, Mac OS X 10.5.8 or later, Processor speed: Minimum 400MHZ, Memory Capacity: Minimum 128MB, Resolution Scan: Minimum 300dpi, Print Copy Minimum 600 dpi, Paper Sizes: A3, B4, A4R, A4, B5R, B5, A5R, Envelope (COM 10, Monarch, ISO-C5, DL), Connectivity: Ethernet 100BASE-TX / 10BASE-T, USB 1.1 / 2.0.

18. AICRP on National Seed Project (Crops),AAU, Jorhat

Gas Analyser for fumigation

studies

Oxygen and Carbon dioxide Analyzer; O2: EC Sensor, CO2: Infrared, Dual wavelength sensor, Voltage: 90-260 VAC (50-60 Hz) True colour graphic display, upto 500 product setup programmes for alarms and data sorting, data logging capabilities of more than 10000 test results, Built in alarm for high and low gas concentrations, Resolution: 0.1% O2 and CO2, Gas cylinder O2 with regulator and manifold, sample container, 2-5 kg capacity, 10 and 20 kg capacity.

19. AICRP on PHET, AAU, Jorhat

Digital Data Logger With data acquisition system

8 channel: Temperature / Process datalogger Universal input: J,K,R,S,B, RTD (Pt-100)/2 or 3 wire, (4-20 mA, (0-1)V, (0-5)VDual display for channel Number & process value; Input: User selectable for each channelRange: 0 to 20000Reference junction support : YesAccuracy: ± 0.1%Resolution: 0.1Logging interval: 1 to 99 min (user selectable) Logging Types: Continuous / Value Triggered / TimeReal Time :   Internal Real Time Clock with Battery Back

Page 12:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

USB Host Port for connecting USB; USB to PC interference with software;

Storage: Store the data included minimum for last 7 days for all channel;

Operating Power : 230V AC, 50Hz with suitable external power adaptor;

Any external device necessary for operation should be included.Data acquisition: 500GB 7200 RPM SATA ; Memory: 4GB; OS:W7 64B

20. AICRP on PHET, AAU, Jorhat

Water activity meter

Measuring Principle: Resistive - electrolyticMeasuring Range: 0.20 to 0.80 aw

A ccuracy: +/- 0.030 aw, Repeatability: +/- 0.01 aw

Display: Reflective, high contrast LCD - display, dimension: 35 x 69 mmOperating: 3x multi-function keys including On / OffMeasuring chamber: standardised sample dishesSpring-loaded measurement head External universal power supply Spare pre-filters & Tension ringRHAccuracy: ± 0.003 aw ;

21. AICRP on PHET, AAU, Jorhat

Vertical gel electrophoresis assembly with power supply

Number of gels :1–4 Precast gels :Ready Gel precast gels Handcast gels: Cast using Mini-PROTEAN spacer plates Gel size (W x L): Precast: 8.6 x 6.8 cm; Handcast: 8.3x7.3 cm ; Glass plate size (W x L)      Short plate : 10.1 x 7.3 cm ;   Spacer plate : 10.1 x 8.2 cm Total buffer volume for 2 gels : 700 ml ; Total buffer volume for 4 gels : 1,000 ml ;Typical run times for SDS-PAGE : 35–45 min (at 200 V constant) Power supply: To run on 220 V AC

22. AICRP on Weed Management, AAU, Jorhat

Drone:(Phantom 4 Specs)

Aircraft

Weight (including battery and propellers) 1380 gMax Ascent Speed 6 m/s (Sport mode)Max Descent Speed 4 m/s (Sport mode)

Max Speed 20 m/s (Sport mode)Max Service Ceiling Above Sea Level 19685 feet (6000 m)

Max Flight Time Approx. 28 minutes

Operating Temperature 32° to 104° F (0° to 40° C)

GPS Mode GPS / GLONASSHover Accuracy Vertical:

+/- 0.1 m (when Vision Positioning is active)

Page 13:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

or +/-0.5 mHorizontal: +/- 0.3 m (when Vision Positioning is active) or +/-1.5 m

Diagonal Size (Excluding Propellers) 350 mmForward Vision System

Obstacle Sensory Range 2 - 49 feet (0.7 - 15 m)

Operating Environment Surface with clear pattern and adequate lighting (lux > 15)

Camera

Sensor: 1/2.3” (CMOS), Effective pixels:12.4 M

Lens: FOV 94° 20 mm (35 mm format equivalent) f/2.8, focus at ∞

ISO Range: 100-3200 (video) 100-1600 (photo)

Shutter Speed: 8s -1/8000s

Image Max Size:4000×3000

Still Photography Modes: Single shotBurst shooting: 3 / 5 / 7 framesAuto Exposure Bracketing ( AEB ): 3 / 5 bracketed frames at 0.7 EV BiasTimelapseHDR

Video Recording Modes:UHD: 4096×2160 (4K) 24 / 25p3840×2160 (4K) 24 / 25 / 30p2704×1520 (2.7K) 24 / 25 / 30pFHD: 1920×1080 24 / 25 / 30 / 48 / 50 / 60 / 120pHD: 1280×720 24 / 25 / 30 / 48 / 50 / 60p

Max Video Bitrate:60 Mbps

Page 14:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

Supported File Formats:FAT32 ( ≤ 32 GB ); exFAT ( > 32 GB )

Photo: JPEG, DNG ( RAW )Video:MP4, MOV (MPEG-4

AVC/H.264)Supported SD Card Types: Micro SD

Max capacity: 64 GB. Class 10 or UHS-1 rating required

Operating Temperature: 32° to 104° F ( 0° to 40° C )

ChargerVoltage: 17.4 V

Rated Power: 100 WApp / Live View

Mobile App: DJI GOEIRP: 100mW

Power Spectral Density: 6.9mW/MHzLive View Working Frequency: 2.4GHz ISM

Live View Quality: 720P @ 30fps Latency: 220ms (depending on

conditions and mobile device)

Required Operating Systems: iOS 8.0 or later Android 4.1.2 or later

Accessories: (i). Installation software(ii). Operating System (Samsung tabs

705C or iPad Air 2 or Samsung NOTE4 or any other

with compatibility and best quality)(iii). Additional Battery 2 Number. (iv). Any other accessories required for

the drone

Page 15:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

23. Management of green waste for economic benefit and women empowerment, Dept. of FRM, AAU, Jorhat

31K Leather stitching machine

S with link machine mechanism, suitable for canvas and leather, pressure boot can be controlled by hand or by knee lifter, industrial heavy duty machine

24. Onychomycosis in agricultural workers of North – East India: Epidemiological study and molecular characterization of the etiological agents.” Dept of Plant pathology, AAU, Jorhat

Bench Top Centrifuge

Capacity 4X57 ml cap. Permitted density (kg/dm3) 1.2, Centrifugal acceleration (G) 2000 Kinetic energy max. (nm) 20, Motor rating input (W) 12, Motor rating output (W) 8. Speed range (rpm) 3500 rpm, Reversible direction of rotation, no speed deviation (%) 5, Power –on –time ON (min) 99, Timer yes, Timer display 7 segment LED, Permissible ON time (%) 100, Unbalance sensor no, Quick stop yes, Cover opening automatic, Rotor exchange without tool, Protective cover yes, Dimension (WxHxD) (MM) 155x105x175, Weight (kg) 1.4, Permissible ambient temperature (0C) 5-40, Permissible relative moisture (%) 80, Protection class according to DIN EN 60529 IP 30, USB interface no RS 232 interface no, analog output no, Voltage (V) 100-240, Frequency (Hz) 50/60, Power input (W) 12, DC Voltage (V=24), Current consumption (mA) 500

25. Onychomycosis in agricultural workers of North – East India: Epidemiological study and molecular characterization of the etiological agents.” Dept of Plant pathology, AAU, Jorhat

Lyophilizer Capacity 3.25 litres approx, CE approved

26. Identification of genes contributing resistance to Alternaria brassicae from a nonhost plant and their characterization in Arabidopsis for durable crop protection against blight disease in Brassica rapa

Plant growth chamber

Temperature: 5ºCto 50ºC (lamp off) /10ºC to 50ºC. (lamp on);Max. to 20,000 Lux;40 to 80% RH (at 20~35 ºC);300 to 5,000ppm CO2 control (optional); High intensity and uniformed luminescence distribution;Wide inner tempered glass door for clear observation of plant growth;Adjustable shelves; Availability of water supply during operation; Auto-tuning / Calibration

27. Identification of genes contributing

Refrigerated shaker

Speed range: 10 to 500 rpm; Temperature range: Amb. -20°C (Min.

Page 16:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

resistance to Alternaria brassicae from a nonhost plant and their characterization in Arabidopsis for durable crop protection against blight disease in Brassica rapa

incubator +4) to 80°C;Microprocessor PID control and auto-tuning; Three-point temperature calibration;Chambers stackable, up to two or more levels;Automatic shaking speed adjustment in case of excessive workload; Shaker protection system against over-current

28. GENOME AND TRANSCRIPTOME SEQUENCING OF AROMATIC RICES FROM NORTH EASTERN REGION

Gel Documentation System

Bioimaging system (PC based) for publication quality image capture and analysis of fluorescent nucleic acid gels, colorimetric protein gels etc. It should include darkroom, UV transilluminator, camera, cables, Image acquisition and analysis software compatible with Window OS. Camera: minimum 12 bit CCD camera with option to export image to 16 bit image; Image resolution: >4 megapixels or equivalentsMain body & Darkroom should be Lightweight modular design with wide access door, gel viewer window, retractable sliding transilluminator tray for placing benchtop transilluminators.Should be quoted with matching Benchtop large UV transilluminator with minimumarea 25 X 26 cm for nucleic acid gels along with requisite emission filters.Necessary Acquisition and Analysis Software that controls the camera functions, image capture and image enhancement, and facilitate image saving in various file formats including TIFF, JPEG, BMF & GIF etc.Must be supplied with desktop computer for operation with genuine Windows OS (at least 4GB, RAM & 500 GB HDD, Intel Core i3, 18.5 inch display) with a laser printer.All equipment should come with 3 years on-site warranty after installation and on-site training

29. GENOME AND TRANSCRIPTOME SEQUENCING OF AROMATIC RICES FROM NORTH EASTERN REGION

Thermal cycler

Should come out Independently-controlled blocks system which can be independently controlled. Option to add 96 X 0.2 ml Block should be there. Should have Gradient facility with minimum 8 temperature zone gradient functionality without sacrificing uniformity in each block.Ramp rate should be minimum 4°C/Sec Block Temperature range should be 4°C to99°CTemperature accuracy should be ±0.2° (@95°)Temperature Uniformity should be ±0.4° (@95° C)Gradient Temperature Range should be 30° C to 100° CVolume Capacity should be 10-100μlShould have a memory capacity of >1000 protocolsShould have pre loaded protocolsThe System should have a Display Size 7 inches at least with Display

Page 17:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

Type Full Touch LCD .Must quote swappable, independent 96–deep well reaction module for running PCR reactions in plate or tube formats as accessory.Should be licensed for Research. All equipment should come with 3 years on-site warranty after installation and on-site training.

30. GENOME AND TRANSCRIPTOME SEQUENCING OF AROMATIC RICES FROM NORTH EASTERN REGION Gel

electrophoresis system

Comprised of two basic unit Gel electrophoresis system to run the gel size of at least 25 x 10cm, 25 x 15cm, and should be supplied with 25 x 15 & 25 x 10 cm Tray along with the Gel tank, safety lid, Tape free casting module, Comb and Comb holder. The supplied gel trays should be UV proof and the trays can be directly kept on the UV transilluminator and should have a integrated fluorescent ruler in the tray.Must be supplied with two number of system compatible 26-Well Comb of 1.5 mm thick with adjustable height. One number of 25 x 10 cm gel tray and one number of 25 x 15 cm gel tray.  All equipment should come with 3 years on-site warranty after installation and on-site training.

31. GENOME AND TRANSCRIPTOME SEQUENCING OF AROMATIC RICES FROM NORTH EASTERN REGION

Spectrophotometer

Microprocessor controlled Double Beam UV/Vis Spectrophotometer with scanning, kinetic and multi wave length measurement facility. Instrument should have internal wavelength calibration facility. 1. Wavelength Range (nm) : 190-900; 2. Wavelength Accuracy ((nm) : 0.2 or better; 3. Wavelength Repeatability (nm): 0.2 or better; 4. Spectral Bandwidth (nm) : 0.5 to 4.0 or better; 5. Light Source : Deuterium & Tungsten Halogen Lamp; 6. Monochromoter : Holographic grating; 7. Photometric Mode : Absorbance, Transmittance (%); 8. Photometric Range : 0 to 3.0 Abs or better; 9. Photometric Accuracy : ± 0.005 Abs at 1 Abs; 10. Photometric Reproducibility : ± 0.002 Abs at 1 Abs; 11. Scan/Skew Speed : Min 2500 nm/min or better; 12. Detector : Photo Multiplier Tube/Silicon Photo Diode; 13. Temperature controller : Peltier system for both sample and reference beam. ; 14. Quartz Cuvettes : Two pairs (0.7 ml capacity, 10 mm path length), Two pairs (1.4 ml capacity, 10 mm path length); Two pairs (3.5 ml capacity, 10 mm path length); Minimum One Years Warranty post-installation

32. AICRP on Honey bees and pollinators, AAU, Jorhat

Binocular microsope

Binocular dissecting,Built-In Both incident(top)Lighting and Transmitted(bottom) Lighting,Four Magnification settings 20x,30x,40x & 60x with camera attachment

33. AICRP on Honey bees and pollinators, AAU, Jorhat

LCD Projector Good quality, contrast ratio;3000;1, Aspect Ratio : 16:10

Page 18:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

34. AICRP on Honey bees and pollinators, AAU, Jorhat

Copier and fax machine

For Printing,copy,scan,fax,email Color: up to 36 ppm,Black: up to 36ppm, Paper capacity : standard

35. AICRP on Honey bees and pollinators, AAU, Jorhat

(a)Apis mellifera

Beehive(Langstroth) with 4 frame seed colony

36. AICRP on Honey bees and pollinators, AAU, Jorhat

(b)Apis cerana Beehive ISI-A type with 4 frame seed colony(i)Wooden(ii)Bamboo

37. AICRP on Honey bees and pollinators, AAU, Jorhat

(c)Trigona Beehive with seed colony

38. AICRP on Honey bees and pollinators, AAU, Jorhat

(d)Beehive stand

Iron(four frame)

39. AICRP on Honey bees and pollinators, AAU, Jorhat

(h)Queen excluder sheet

Apis melliferaApis cerena

40. AICRP on Honey bees and pollinators, AAU, Jorhat

(i)Swarm catcher

Good quality

41. DIC-IIT project on ‘Development of automatic fish seed grader cum counter’ at Fisheries Research Centre, AAU, Jorhat-13

Precision laboratory balance

(economical)0.001g-300gm

Page 19:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

42. DIC-IIT project on ‘Development of automatic fish seed grader cum counter’ at Fisheries Research Centre, AAU, Jorhat-13

High precision table top balance

0.1g-10kg

43. DIC-IIT project on ‘Development of automatic fish seed grader cum counter’ at Fisheries Research Centre, AAU, Jorhat-13

Microprocessor pH meter

2 point calibration

44. DIC-IIT project on ‘Development of automatic fish seed grader cum counter’ at Fisheries Research Centre, AAU, Jorhat-13

Nursery fishing net

1) Size- 45mt X 8mt2) Size- 25mt X 8mt

45. DIC-IIT project on ‘Development of automatic fish seed grader cum counter’ at Fisheries Research Centre, AAU, Jorhat-13

Multifuel pump with all accessories

Power: 2HP

46. DIC-IIT project on ‘Development of automatic fish seed grader cum counter’ at Fisheries Research Centre, AAU, Jorhat-13

Drill Machine (10mm)

Page 20:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

47. DBT sponsored project on “Biodiversity Studies of Aromatic Rice in North-East India”

MULTICAPILLARY ELECTROPHORESIS SYSTEM

A fully automated gel-free capillary electrophoresis system for high throughput nucleic acid analysis of up to 96 samples in one run within 30-45 minutes. It should be able to perform automated DNA & RNA fragment analysis. System should come with Ready-to-run cartridges allowing 96 samples to be analyzed without use of ethidium bromide. It should be possible to use the capacity of the cartridge partially and reuse after storing the same.It should offer the advantage of dual format (gel based and peak based) data analysisSystem should offer a resolution of fragments less than 5 bp.Real time monitoring of the sample analysis should be visible on the computer screen immediately after the starting of a run. System should work with an input volume of less than 1 μl offering a high sensitivity of up to 1000pg. System should analyse Post PCR samples directly for fragment analysis without prior purification of samples.The instrument should be capable of being used for VNTR/MultiLocus VNTR, SSR/STR, Microsatellites, ISSR analysis, genotyping, restriction digestion, PCR- RFLPs qualitative single-plex or multiplex PCR, PCR-based cDNA library screening and other routine molecular biology applications. System Technology: Capillary electrophoresis; Operating temperature: 20- 28°C;ExcitationSource: light-emitting diode; Ready-to-use gel cartridges; Robust results for nucleic acid concentrations as low as 0.1 ng/μl; Standardized and accurate analysis with a resolution down to 3–5 bp.Instrument should come with user-friendly analysis software and necessary data capture equipment.All necessary components / accessories required for installation and smooth running for the equipment to be quoted. The running cost of the equipment in terms of cost per fragment must be included alongwith supporting literature.

48. AICRP on AGROMETEOROLOGY, AAU, JORHAT Net radiometer

Response time (95%):<60s; Non-linearity (over full range)<1%; Temperature dependence of sensitivity: -0.1%/ ºc (typical); Sensitivity: 10µV/W/m2(nominal); Spectral range (50% points):200nm to 100 nm; Field of view:180ºUpper and lower sensor; Mounting rod: Fixed, 800mm longx20mmø; Standard cable: 15m fixed cable; Operating Temperature Range: -40ºto 80ºc

49. AICRP on AGROMETEOROLOGY, AAU, JORHAT

Line Quantum Sensor

Sensitivity: 7µA/100 mole/s/m2; Response time :10µs; Temperature sensitivity: 0.15%/ ºc

Page 21:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

50. AICRP on AGROMETEOROLOGY, AAU, JORHAT

Soil thermometer (glass type)(5,10,15cm)

51. AICRP on AGROMETEOROLOGY, AAU, JORHAT

Luminous Solar Inverter 850 KVA

52. AICRP on AGROMETEOROLOGY, AAU, JORHAT

Sunshine cards (long curved cards, short curved cards and straight cards).

53. AICRP on AGROMETEOROLOGY, AAU, JORHAT

Rainfall Charts As per IMD specification

54. AICRP on Fruits, AAU, Jorhat

Sterioscopic Binoclar Research Microscope

Binocular Zoom Stereoscopic Microscope, Zoom ratio 1.4. long working distance : 82mm with dual light stable stand with ball bearing slides & large size knobs for smooth focusing. Dual illumination Built in illumination both for incident light (12v-20w Halogen) and transmitted light (12v-10w) on dual light stand. Binocular zoom Pod 1:4 inclined at 450 .Inter papillary distance 54mm-74mm. with fixed or focusable movement. Stage plate: One of 5mm thick glass, another one of moulded ABS-one side black other side white, easily replaceable, with 2 stage clips.Eyepieces Paired Objectives1x-4x Standard Zoom objective 2x-8x with Aux.2x objectiveWith 10x WF(FN20) 10xto40x 20x to 80xWith 15xWF (FN15) 15x to 60x 30x to 120xWith 20x WF (FN 13) 20x to 80x 40x to 160x

Total Magnification Range 10x to 160x with optional Eyepiece & Auxillary Objective.

55. AICRP on Fruits, AAU, Jorhat

Electronic Weighing Balance

Electronic Weighing Balance: Portable/Top loading Balance with 3000g capacity; 0.1g readability;+ 0.1g linearity: EA 3000(Imported)

Page 22:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

56. AICRP on Fruits, AAU, Jorhat

Autoclave AUTOCLAVE VERTICAL type with Digital Temp. Controller cum indicator and sensor to control temperature, connected to Timer (0 to 99 minutes) for semi auto operation. Inner body is made of heavy gauge stainless steel welded; the lid & the ring are made of stainless steel plate. The lid heavily polished & is fitted with pressure gauge, safety valve & steam exhaust valve & safety value is set to blow of 20lb./sq.inc to remove excess steam & maintain constant pressure. a molded single piece rubber gasket is fitted in the ring to ensure tight joints, outer cover made of polished stainless steel; with CI legs; fitted with immersion water heater/s & foot lifting arrangement. WORKING SIZE: 12" X 12" DIA X HT: 30 x 50 cm RATING: 2.0 KW CAP. : 30 Ltrs Appx. Inner: STEEL OUTER: MS PAINTED CAPACITY, Ltrs Approx: 178With following features:(a) Low water level cut off Device for above Autoclaves (b) Electric Time Switch (c) Vacuum Breaker for Safety Device pressure gauge. After sale support : JORHAT, Assam

57. AICRP on Fruits, AAU, Jorhat

Banana Fiber Extractor

1 H.P ISI motorHard chrome bladesRoyal Blue ColourType : Agri. Based Machinery

58. AICRP on Fruits, AAU, Jorhat

Tree height Gauge

Digital height Gauge, Model no-1150-1000, Type B, Range (mm): 0-1000mm, Stainless steel, Battery SR44, LCD display.

59. AICRP on Fruits, AAU, Jorhat

Fertigation unit with drip system for 2ha of area in Banana plantation

Main lne 75mm PVC pipe 4kg/cm2, Submain line 63mm PVC pipe 4kg/cm2, Lateral 12mm 2.5kg, Self cleaning PC dripper 4.2 lph, Grommet take off 12x8mm, Barbed poly jointer 12mm, Lateral end stop 8 shape 12mm, Screen filter 25m3/hr, Ventury mainifold GI+MGV 2, Ventury assembly complete ¾, Flash valve 63mm, PVC air release valve, Air release valve assembly 63mm, control valve 63, elbow (equal) 63mm HD, elbow (equal) 75mm HD, Reducer S/S 75x63mm HD, Male thread adopter 63mmHD, Female thread adopter 63mm HD, Tee (equal) 75mm HD, Tee (equal) 63mm HD, End cap (plain) 75mm, End cap (plain) 63mm, Pressure gauge ¼”, solvent cement.

60. AICRP on Fruits, AAU, Jorhat

Precision Weighing Scale 

Capacity (Max) 30kg, Readability 0.001kg, nmax-30,000, Platter 220x290mm all stainless steel, Dual power source.

Page 23:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

61. Biodiversity Studies of Aromatic Rice of North East India, RARS, Titabar

PCR (Multiple Block Gradient PCR)

1. The system should be a Multiple Block Gradient PCR with 64 / 32 x 0.2 mL PCR tubes; 45 / 17 x 0.5 mL PCR tubes

2. System should have Independent block operation, with separate run status access

3. Gradient PCR, with gradient range should be of 12°C (8-column gradient (0.2 mL tubes); 7-column gradient (0.5 mL tubes)

4. Gradient temperature should be in range: 30 - 99ºC5. Block temperature control range: 4°C to 99°C,

Temperature Accuracy: ± 0.2°C 6. Heating rate: 3 °C/s; Cooling rate: 2 °C/s7. Should have Intuitive Graphic programming with larger

display8. System should have administrator and user login with or

without PIN for enhanced security9. Auto Restart facility with user defined time interval when

power fails and resumes10. Two USB ports: for Protocol transfer, Self-test, USB,

printer / mouse11. Maximum power consumption: 700 W12. Warranty period of 5 years should be provided.

62. Biodiversity Studies of Aromatic Rice of North East India, RARS, Titabar

Gel documentation system

1. Gel documentation system with in-built touch screen computer, Should have motorized zoom lens

2. Dark room with full slide out UV transilluminator on pull-out rails for comfortable work

3. UV safety shutoff with widely accessible door to handle gels while placing or moving gels on transilluminator table

4. Scientific grade camera with native image resolution of at least 2600 (H) x 1950 (V) yielding image resolution of 5 megapixels

5. Field of imaging must be at least 26 x 21 cms6. System should have analysis software for image enhancement, image analysis

includes molecular weight calculation, band quantification, distance calculation.

7. System should be supplied with refrigerated Centrifuge should be 18-places Microcentrifuge with Maximum Speed of 16873xg /14000 rpm

8. Instrument should have a maximum rotor capacity of 18 x 1.5/2mL tubes9. Temperature range should be of 0 deg C to 40 deg C 10. System should be of guaranteed temp of 4 Deg at maximum rotational speed

with ECO Power shut-off facility11. Timer should be of 30 s to 9.59 hr with cont run function12. Warranty of the instruments should be of 5 years .

Page 24:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

63. Development of High yielding, Non lodging and Biotic resistant Varieties of Black Scented Rice of Manipur and Joha Rice of Assam through Biotechnological Intervention, RARS, Titabar

PCR (Ultra Fast Thermal Cycler)

1. SIlver block for 96 x 0.2 mL and 1 x 96-well PCR Plate (unskirted / semi-skirted and fullskirted PCR plate)

2. Should support minimum Sample working volume of 5μL, without the need to use liquid wax or overlaying.

3. Temperature control of block: 4 to 99°C4. 12-Column gradient block with Steady Slope technology,

selectable from 1 to 20° C across the entire temp. control range

5. Gradient should be capable of running at the specified ramping rates.

6. Block Homogeneity (20 – 72°C): ≤ ± 0.3°C; (95°C): ≤ � �±0.4°C

7. Control Accuracy: ±0.2°C, Heating rate: 6°C/Sec; Cooling rate: 4.5°C/Sec

8. Auto restart option in event of Power failures9. Display to indicate cycler number in a network, with

possibility to network at least 5 unitscontrollable through single control panel

10. PC controllable higher throughput upgradability up to 30 units should be possible in future

11. Must have following interfaces: Centronics, USB, CAN in, CAN out

12. Calibration according to NIST, DKD, UKAS standards, Must have CE, ISO certification and comply to RoHS

13. Warranty of the instruments should be of 5 years .Accessories: Utility: Everyday Use Type: Notebook Screen Size: 13.3 Inch, Processor: Core i5, RAM: 16 GB

Hard Disk Capacity: 1TB, Operating System: Mac OS, Generation: 5th Generation, Graphic Processor: Intel HD Graphics 6000

64. Development of High yielding, Non lodging and Biotic resistant Varieties of Black Scented Rice of Manipur and Joha Rice of Assam through Biotechnological Intervention, RARS, Titabar

-200 Deep freezer

1. Temp Range : –16*C ~ –25*C2. Cap : 340 Ltrs,3. Door : Solid Door4. Dim : 24 x 25 x 735. Storage Type : 2+5 Pull Out Drawers6. Wheels : 2 Rear wheels7. *Tropical zed at 43*C8. *Body Insulation – 80 mm9. *A+ Category–Low Power Consumption 0.78 unit/ 24 Hrs10. Should have optional fittings: Lock & Digital Temperature

Display

Page 25:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

65. Development of shorter duration of the mega variety Ranjit with the help of mutation and breeding and marker aided selection, RARS, Titabar

Balance 1. Capacity: 220 g2. Readability: 0.1 mg3. Repeatability: +/- 0.1 mg.4. Linearity : +/- 0.3 mg5. Pan size: 90mm dia6. Response time: 3-4 sec.7. Display: Back light LCD Display.8. Calibration: Internal Motorized Calibration.9. Units of Measure: gm, lbs, tl, momme, ounces,ct, GN, ozt, dwt,

pennetc10. Operating Temp: 10°C to 40°C.11. Tare range: Full 12. Power supply: A/C Adapter 230V or 115V +/- 20% 50-60 Hz

66. Genetic enhancement of rice for low moisture stress tolerance, RARS, Titabar

PCR machine (Gradient PCR)

1. System with Universal Block for 96 x 0.2 ml PCRTube, 71 x 0.5 ml PCR Tube, One 8 x 12 PCR Plate

2. System should be gradient PCR, capable of testing 12 different temperatures simultaneously across a gradient range of 1 - 20°C

3. System should having SteadySlope Gradient Technology ensures ramp rates are identical in both gradient and normal operation.

4. Temperature Control Range : from 4° C to 99° C5. Lid Temperature range : 37° C to 110° C6. Block Temperature Accuracy : ± 0.2° C, Gradient range from 1

°C to 20°C, Gradient Temperature Range : 30 0C to 99 0C, Block Homogeneity :-20 0C to 72 0C : < + 0.3 0C95 0C : < + 0.4 0C

7. Temperature control speed approx. 3 °C/s (heating )8. Temperature control speed approx. 2 °C/s (cooling)9. Intuitive Graphic programming with larger display10. Auto Restart facility with user defined time interval when power

fails and resumes11. System memory of more than 100 User folders and more than

700 programs12. Warranty period of 5 years should be provided.

67. AICRP(Fruits), CRS, AAU, Tinsukia

Ultra Deep fridge (-80°C)

Single compressor, low energy consumption, low heat dissipation,100% HCFC/CFC freeDim. ExteriorWXDXH(mm):600x680x810Net capacity: SSL, Temperature range:-8soC/-40°C,Power supply: 230V,Frequency: SO/60Hz

Page 26:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

68. AICRP(Fruits), CRS, AAU, Tinsukia

Incubator cum shaker

Instrument is to be designed in such a way that it can accommodate 5Oml,100ml, 250ml, 5OOmland 1000mlflask.Motion: Orbital,Speed: 30-2S0rpm, Speed Controller:Digital, Platform size: 400x360mm,Tray: Universal Tray with springs,Temperature range: above ambient to600

( checked at 28°), Controller: DigitalPID controller.

69. AICRP(Fruits), CRS, AAU, Tinsukia

UV-VIS Spectrophotometer

UV-Visible Double beam spectrophotometerWave length range: 190-11 OOnm,Spectral Bandwidth:2nm(Snm,4nm.lnm, O.Snm optional),Wavelength accuracy: ±O.3nm,Wavelength reproductibility:=O.ISnm,working mode:T,A,C,EBaseline flatness:±0.002A,Stability:=O.OOIA(at SOOnm,afterwarming up)

70. AICRP(Fruits), CRS, AAU, Tinsukia

ELISA reader & 80 columnDot matrix printer

With on-board data reduction & reporting - Reads 6,12,24,48 & 96 wellmicro plates, Flat, U&V bottom forwide range of applications.Wavelength: 400-750nm, absorbancerange: 0.000 to 3.000 O.D., Filters:405,450,490 & 630nm, onboard endpoint & curve fit read mode, serialRS232C, parallel printer interface,230V AC, 50/60Hz with 80 columnDot matrix printer for hard copy ofresults.

71. AICRP(Fruits), CRS, AAU, Tinsukia

Liquid Nitrogen can

Cryogenic container (Liquid nitrogen can) capacity: 10.SL, State evaporationloss :0.1 17L1day, Static holding time:90 days, working time: 120 days, Totalheight: 550mm, strawholding capacity

72. AICRP(Fruits), CRS, AAU, Tinsukia

Autoclave NIL

73. AICRP(Fruits), CRS, AAU, Tinsukia

Net House for elite candidate

25M(length )x6M(breadth )x3M(Height) insect proof net house with GI pipeI fittings & double door @ 2.5 lakh/unit

74. AICRP(Fruits), CRS, AAU, Tinsukia

Net House for rootstocks &PF planting material

25 M(length)x6M(breadth)x3M(Height) insect proof net house with GI pipefittings & double door @ 2.5 lakhlunit

Page 27:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

75. AICRP(Fruits), CRS, AAU, Tinsukia

Water purification system

NIL

76. AICRP on IFS, AAU, Jorhat

Paddle Thresher

Manually operated

77. AICRP on IFS, AAU, Jorhat

Kellplus digestion set(glass tube)

Good quality

78. AICRP on IFS, AAU, Jorhat

Standard IS sieve

5,1,0.2 & 0.1mm sieve size

79. AICRP on Agro Forestry, HRS, Kahikuchi

Irrigation facilities

1. 3” GI Pipe Medium (ISI) 250 metre2. 2” GI Pipe Medium (ISI) 706 metre3. 3” x 2” Reducing Tee 2 nos.4. 2” Tee 2 nos.5. 2” Gate Valve Scud (ISI) 15 nos.6. 2” x 6” Nipple 30 nos.7. 3” Tank Nipple 1 no.8. 3” Bend 2 nos.9. 3” Union 3 nos.10. 2” Union 16 nos. Other fitting and acessories

80. Crop condition assessment under abiotic stress of few selected major crops of NER using remote sensing technique

.Green Seeker *Crop Sensor should be Hand Held Type *Provide direct NDVI values *Can be used in Indian Conditions and crops *It should be calibrated for Indian Conditions *Provide the list of users in India

81. Crop condition assessment under abiotic stress of few selected major crops of NER using remote sensing technique

Inverter for CNH analyser

*6 KVA *Sufficient back up atleast 3 hours

Page 28:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

82. Development of improved moisture stress tolerant variety in Indian mustard through mutation breeding.

Rainout Shelter

*Total floor Area: 50 m2 *Structure: single span naturally ventilated*Polycarbonate sheet *40 Mesh insect proof net to protect from insect, dust and rain shower in sides.*Should be raised up to 45 cm with fertile soil *Brick in cement mortar with good finish up to 60 cm from plinth level in all sides*Provision for rain water harvesting *Warranty: Minimum one year with free maintenance

83. Strengthening/ establishment of Biofertilizer and Biocontrol Producdtion Units for increasing pulse production in India

Vertical Autoclave

(Big)

Description: Autoclave(vertical) with thermostatic controlCapacity: 100LitresMaterial: stainless steel 316 grade in side chamber & outer M.S sheet powder coatedHeat Source: Internal electric element 2.0kw 239V 50Hz ACWorking temperature:121 degree COperating pressure :15-20 PSI(All S.Steel inner 4 outer)Digitally operated

84. Strengthening/ establishment of Biofertilizer and Biocontrol Producdtion Units for increasing pulse production in India

Horizontal Autoclave(Bi

g)

Autoclave(Horizontal rectangular type)Capacity 100LitersMounted on a M.S. tubular stand. Inner & Outer chamber & steam jacket are made of S.S. 304. Steam jacket allows Dry sterilization. Hinged door is made of Stainless steel with Radial locking arms. Gasket is of synthetic neoprene, Steam is generated in a separate boiler which is placed below the Main body. The steam generator is fitted with easily replaceable Heaters and water level indicator. Autoclave hold pressure at selected Point between 10 to 20 psi +/- 3 psi pressure control switch has Markings which are approximate, correct pressure is as shown by the pressure gauge Hydraulically tested at 40psi. Fitted With safety valves, pressure gauges, air filter, steam release valve, Stream trap, and one tray. 1Kg. Cm2 = 14.7 psi.

85. Strengthening/ establishment of Biofertilizer and Biocontrol Producdtion Units for increasing pulse production in India

Hot air Oven Sturdy double walled units with outer chamber made of M.S sheet duly enamel with inner made up of anodized aluminium or S.S sheet. The gap between inner and outer chamber is filled with high grade glass wool to avoid thermal losses. Beaded heating elements are placed in ribs at bottom and sides. Inner chamber is provided with ribs for adjusting perforated shelves to convenient height. Temperature is controlled by imported hydraulic type capillary thermostat from 50degree C to 250 degree C ± 1 degree C. An-L dhaped prismatic thermometer is fitted to the unit for reading the chamber temperature. Air ventilators are also provided on the sides of Unit. To work on 220/230voltsA.CSize 605×605×605Capacity 224litres

Page 29:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

86. Strengthening/ establishment of Biofertilizer and Biocontrol Producdtion Units for increasing pulse production in India

Open air shakers(Large)

Electronic adjustment of speed and timerDigital display makes it possible to read the speed, timer function and operating modes Electronic time switching clock: 0 - 9 h 59 min or continuous operation (endless)With integrated end point positioning (for automated robot-controlled sampling)All functions can be controlled and documented with labworldsoft®Special version with reverse rotating direction on requestWide range of attachment combinations makes it possible to use almost all shapes and sizes of vesselsIncluding: Universal attachment tray for various types of vessels. Infinitely variable clamping rolls allow universal adaptation to the vessels.Holding capacity- 5000ml flasksShaking limit- 5 to 6 flasks at a timeSpeed:5-5000rpmWith adjustable rods

87. Strengthening/ establishment of Biofertilizer and Biocontrol Producdtion Units for increasing pulse production in India

Foot Sealing Machine

Foot operated:Red:60cm(Pedal Bag Heat Sealing Machine Packaging Machinery Pedal Bag Heat Sealer)

88. Strengthening/ establishment of Biofertilizer and Biocontrol Producdtion Units for increasing pulse production in India

B.O.D Incubator

Temperature: 5-60 degree CPower-220 voltsTemperature Accuracy : + / - 0.5°CTemperature Control: Microprocessor ControlCabinet: M.S. Steel Powder CoatedShelves :1 to 5 Stainless SteelInsulation :Polyurethane FoamWith glass doorAir Circulation: Fan or BlowerHeating System: U Shaped S. S. Nichrome WireWith Interior LightDisplay :LED / LCDCooling :CFC FreeRefrigerant :R134a with Air Heater

89. Strengthening/ establishment of Biofertilizer and Biocontrol Producdtion Units for increasing pulse production in India

Industrial Mixer Grinder

Capacity- 1000kgsMotor: HP 2Size: 35×20×34’’ Gross weight- 110kgs

Page 30:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

90. DIC(IIT Ghy) project “ Design &

Performance….…….NE Region”

Pyranometre/ Solar radiation

sensor

1. Solar radiation received in plane surface expressed in Watt/m2 .2. In an 1800 field of view angle.3. Output both in digital and analogue.4. With Solar radiation Data logging facility, complete with accessory

Temp. = 0° to +65° CRange = 0 to 1800 W/m2

Out put = 0 to 3 VDC (0- 1800 w/m2)Displays – Solar irradianceAdditional feature – To integrate theirradiance values and displays total incident energy over a set period of time.AccessoryData logging of Solar radiation sensor data2. USB interface cable3. Associated software for transferring data from Logger to computer.Data logger-1. Logging rate – 1min-24hrs2. Memory – 15,000 values.3. With Reset button.

91. DBT project “Molecular breeding for

development of cold tolerant boro rice cultivators at the seedling stage suitable for Assam

condition”

Spectrophotometer

Fixed/open wavelengths at 230 - 600 nm Display of purity scan for specific applications Preprogrammed applications for quick start Integrated application and results memory Data transfer via USB interface Direct printer port available Xenon flash lamp with very long life time Guided software process to minimize errors Compatible with microvolume measuring cells and standard

cuvettes92. DBT project

“Molecular breeding for

development of cold tolerant boro rice cultivators at the seedling stage suitable for Assam

condition”

Bead crusher Shaking Method: Pendular swing method Applied beads : All of nonmetallic beads and some of SUS

beads Shaking Speed: 2,500 - 4,600r/min Timer 5 - 60 sec. countdown Safety device / function Limiter for open/close lid: (Stop

shaking when lid open), Overcurrent protection safety device. Should mix 1.5-5ml tubes Power Supply AC220V

Page 31:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

93. DBT project “Elucidating the role of bacterial

endosymbionts in phytopathogenic fungi for toxin production and pathogenesis.

-20 ° Deep Freezer

The system should be stainless steel exterior and stainless steel interiorShould have reversible door and air forced coolingShould be microprocessor controller with digital displayShould have Approx. 72 hours battery backup for alarms, loggings and temperature display in case of power cut Should be prepared for GSM alarmShould be prepared for connection of two additional probesShould be 3 level password protectedDisplay text should be available in different languagesTemperature graph should be presentShould have RS485/RS232 interface Should have visual and acoustic alarmIntegrated memory should be for 20 yearsShould have probe failure alarm, power failure alarm, instrument failure alarm, Door open alarm, contact for remote alarm,Capacity: 600 to 620 LtrsTemperature range: -20 to 10 °CNo. of compressors: 1Should have adjustable high/low alarm

94. Development of high yielding, non-lodging and biotic

resistant varieties of black scented rice of Manipur and Joha

rice of Assam through

Biotechnological intervention, AAU,

Jorhat

Thermo cycler Should have a sample capacity of 96x0.2ml tubes, 0.2ml tube strips or universal or standard 1x96-well plate of 8x12 format or may be multi-block type totaling 96 well with six or more heating and cooling.

System which are not capable of taking plates will not be considered.

Should have true gradient capability with Dynamic ramping technology , other technologies apart from gradient will not be considered.

Should have the feature of dynamic ramping with identical hold times for all the 8 rows of gradient.

Should have a temperature differential range of 1-25degC across the rows.

Should have intuitive 5.7” (14.5 cm) touch screen interface which can displays graphics in high resolution for easy programming.

The touch screen should be responsive for both gloved and ungloved fingers.

Should be capable of running reaction volumes from 1-100ul. Should have a maximum ramp rate of 3- 4 deg C/second. Should have a temperature range of 4-100 deg C Should have a gradient range of 30-100 deg C Should have a temperature accuracy and uniformity of ±0.5 deg

C Should have a memory of >500 programs with further

expansion through a USB Flash drive for transfer of files. Should have block and calculated temperature control modes. The software should be capable of exporting Run logs and

Page 32:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

system error logs Should have quick boot up time of not more than 1 min. Should be quiet in operation. System should have built in library of standard protocols

for long PCR, fast PCR, reverse transcription PCR etc. Should have the feature of “Instant Incubation” to keep samples

at constant temp for ligation and restriction digests. Should have power save mode. Should be compatible with all kind of plastic consumables

and reagents specially reusable sealing Mats.

95. Augmentation of Agriculture through efficient resource utilisation with Participatory approach

Hot plate 30 x 45 x 18 cm, digital controller PID based, 2 KW, heating up to 3500C, 220-240 V

96. Augmentation of Agriculture through efficient resource utilisation with Participatory approach

Flame photometer

Microprocessor-based, digital display, precision ± 2 % of FSD with 10 mg/l Na-, K-, and 20 mg/l Ca-standard solution. 230 V ± 10 %, 50 to 60 Hz ± 5 %, fuel LPG, air pressure 0.3-0.6 kg/cm2, aspiration time ≤ 30 sec, with K, Na and Ca filters

97. Augmentation of Agriculture through efficient resource utilisation with Participatory approach

UV-vis-spectrophotometer

PC-based, double beam, wavelength range 200-1000 nm (accuracy ±0.5 nm, band width 2 nm), operating in single and multiple wavelength mode, automatic baseline correction, with Tungsten-halogen and Deuterium lamps, minimum 4 sample holders and cuvets.

98. Augmentation of Agriculture through efficient resource utilisation with Participatory approach

Kjeldahl distillation unit

Microprocessor-based, semi-automatic type with time and solvent control

99. Augmentation of Agriculture through efficient resource utilisation with Participatory approach

Digestion assembly

Microprocessor-based temperature control, 20 place, heating up to 350-4000C, with scrubber, table top unit

Page 33:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

100.Augmentation of Agriculture through efficient resource utilisation with Participatory approach

Digital pH meter

pH range 0-14, Resolution : 0.01, Temperature Range : 0.0 to 100ºC (Manual Compensation) Display : 31/2 Digit LED Display, Power Supply : 230VAC ±10%, 50 Hz

101.Augmentation of Agriculture through efficient resource utilisation with Participatory approach

Hot air oven 24” x 24” x 36”, heating up to 2000C, automatic temperature control, stainless steel chamber, 4 shelves

102.Augmentation of Agriculture through efficient resource utilisation with Participatory approach

Analytical balance

Capacity maximum up to 100g, minimum 0.1 mg, 230-240 V with adapter, digital display, open pan with dust cover shield, sliding door

103.Augmentation of Agriculture through efficient resource utilisation with Participatory approach

Water distillation, steel

Stainless steel, wall mounted, capacity 4-5 litre/hour, 230-240 V, 2KW power, accessories heating element

104. Augmentation of Agriculture through

efficient resource utilisation with Participatory

approach

Multi-Function Printer/Scanner/ Xerox machine

Printer Functions Print/Scan/Copy with B/W print output printer brand Xerox, Interface USB, print out time 7.5-10 seconds, tray capacity – 100, additional tray with capacity 250, warranty one year

Page 34:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

105.Wild mushroom from NE India: evaluation of their nutritional status and medicinal properties

Thermocycler Gradient Thermal Cycler with Peltier heating and cooling based system.Can accommodate both 0.5 ml & 0.2ml tubes.Should have a sample capacity of 125 ul.Dynamic gradient capabilityHas an option to add 2 x 48 X 0.2 ml Block or 384 Well Block. All the

blocks have the gradient capability.Has adjustable heated lid Temperature range of 0-100 deg CTemperature accuracy of ± 0.2 deg CUniformity of ± 0.4 deg C well to well within 10 seconds of arrival at 90

degC and have 6 Thermoelectric modules.Gradient range of 30-100 deg C and use dynamic ramping for gradient.High resolution touch screen display with 6 USB ports for Protocol

transfer and multiple connectivity.Memory of >1000 programs with further expansion through a USBFlash drive for transfer of files.Option to protect files with optional log-in, restricted user privileges and

secured mode for controlled environment is there.Has automatic option for graphical or text based programmingThe software has exportable Run logs and system error logsCapable of using through a PC or without it.O-ring seal to protect thermal electric modules.Licensed for Research and IVD Applications.

106.Wild mushroom from NE India: evaluation of their nutritional status and medicinal properties

Orbital Shaker

Shaking Speed : ~250rpm, Orbit 20mm Independent Timer Load Capacity : More than 7 Kg Display : LCD Platform : Universal Platform Power supply : ~ 240V Flask Clamps for 50-100ml : 10 Flask Clamps for 200-~250ml : 10 Flask Clamps for 500ml : 5 Flask Clamps for 1000ml : 5 Platform for the clamps

107.Wild mushroom from NE India: evaluation of their nutritional status and medicinal properties

Digital Magnetic Stirrer and Hot-Plate

Stirring Speed : 100 rpm to 1200 rpm. Stirring Capacity : 10 Ltrs. maximum (at Viscosity of

water) Power Supply : 240V, 50Hz. A.C. Supply Top Plate : Ceramic Dimension : 26 x 26 cm Temp Range : 50 degree – 300 degree. S S Support Rod : 1 Boss Head Clamp : 1 Clamping Rod : 1 External Probe 6 inch : 1

Page 35:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

108.Wild mushroom from NE India: evaluation of their nutritional status and medicinal properties

Micropipettes1 no. of eachvolumes 0.2-2.0 μL, 1.0-10 μL, 2-20 μL , 20-100 μL, 50-200 μL, 200-1000 μL,

Micropiette Adjustable volume of Micropipette Volume Display: at least 3 Digits. Easy removable lower part for cleaning pipette

109.Breeding for higher productivity of indigenous Joha rice of Assam through induced mutations for morpho-agronomic traits, Dept. of PBG, AAU, Jorhat

Electronic Precision Balance

0.1 mg to 120 gAny recognized make

110.“Induced mutagenesis for early maturing plant type of Indian Mustard” Dept. of PBG, AAU, Jorhat-13

Hot air oven Microprocessor controlled with auto time control unit and other accessoriesSize: WxDxH: 43x84x91cmTray capacity: 12

111.“Induced mutagenesis for early maturing plant type of Indian Mustard” Dept. of PBG, AAU, Jorhat-13

Seed storage cabinet

Steel almirah type seed storage cabinet with 8-10 shelves, to be locally made.

112.“Induced mutagenesis for early maturing plant type of Indian Mustard” Dept. of PBG, AAU, Jorhat-13

Top pan balance

Digital, Max. cap. 10 kgAccuracy 0.5gSWIT 105

Page 36:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

113.“Induced mutagenesis for early maturing plant type of Indian Mustard” Dept. of PBG, AAU, Jorhat-13

Electronic balance

Max. capacity 220 g, Accuracy=0.1 mg

114.Office of Spoke Institute (DIC), Department of Family Resource Management, College of Home Science, AAU

Wireless EMG system

The system should have:- Should be able to work in Lab and Field studies (Portable & easy to carry) High speed USB based 16 channels recording station upgradable to 32 or more

channels. The station should provide charging/transmitting console that communicates with

the software to automatically recognise the sensor status for charging, recording and signal strength.

RF Transmitting Range at-least 40 meters and ADC resolution of atleast 16 Bits. High sampling rate of 2-4KHz or more with a variable sampling rate on each

channel. High CMRR Ratio: 80 dB or more Should have software controlled filtering High Pass, Low Pass filters, AC

Coupling, Digital filters, band pass filter & Main filters. Simple recording view, averaging, Zooming, Fast Fourier Transform, Spectrum

etc. Must have a facility for online/offline analysis with MATLAB. The software should have built in smart analysis features like rms, power

spectrum, template matching, curve fitting, cross correlation, Arithmetic & mathematic formulae based calculations.etc.

Wireless EMG Sensor ( 2 Nos.)

Parallel-Bar technology for guaranteed high fidelity signals no motion artifacts.

Each sensor should provide 1 EMG and 3 acceleration signals. Small size lightweight sensors of 37 mm x 26 mm x 15 mm or

less. Software selectable accelerometer sensitivity of ± 1.5g or ±6g

US FDA, ISO &European IEC certificates to be provided. Demonstration & Training free of cost at the site by company experts. Consumables:- Adhesive strips electrodes (1000 nos). The system should be supplied with the branded laptop with latest

configuration

115. Office of Spoke Institute (DIC), Department of

Family Resource Management,

College of Home Science, AAU

Pedometer Digital

Page 37:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

116. DIC sponsored project “Ergonomic design approaches for occupational

wellness of pluckers engaged in manual

tea plucking activity”,

Department of Family Resource

Management, College of Home

Science, AAU

Force Sensitive Resistor

- Wireless FSR sensor -4 channels- Easy to carry for field experiments

117. DIC sponsored project “Ergonomic design approaches for occupational

wellness of pluckers engaged in manual

tea plucking activity”,

Department of Family Resource

Management, College of Home

Science, AAU

Steadiness tester

- Hole type (Electrical) with 9 progressively smaller holes.- Metal-tipped stylus.- With a timer, score counter and fault counter.

118.NASF funded Project entitled ‘Understanding mechanisms of tolerance to low light intensity in rice’ DEPARTMENT OF CROP PHYSIOLOGY:: FACULTY OF AGRICULTURE:: AAU:: JORHAT-13

UV-Visible Spectroph-otometer

Wave length range 190-1,100nmLamp type: Xenon flash lampDouble Beam/Single BeamMeasuring modes: Concentration, absorbance, transmission, multi wavelengths, spectra and kinetics in absorbance, and transmission mode.Special bandwidth: 4nmWavelength resolution:1nm (scan 0.1nm)Wavelength reproducibility: ± 0.2nmWavelength accuracy: ±1nmStray light: ≤ 0.1% transmission at 340nm, ≤1% transmission at 198nmPhotometric range: ±3.0AbsAbsorbance resolution:0.001AbsAbsorbance reproducibility: ±0.003 absorbance at 0.003 Absorbance at 1 absorbance: between 200nm and 900nm.Absorbance accuracy: at 230-900nm:1Absorbance: ±0.005nm absorbance2Absorbance: ±0.005nm absorbance2.5Absorbance: ±0.008absorbance. etc.

Page 38:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

119.DEVELOPMENT AND EVALUATION OF DEHYDRATED AND IRRADIATED JACKFRUIT (Artocarpus heterophyllus) PRODUCTS, Department of Food Science and Nutrition, AAU, Jorhat-13

Tray dryer Capacity: 12 to 24 trays Robust construction. Built on formed angles of 3mm thick sheet and suitably reinforced with angles

and sections. External walls are manufactured from 1.6mm thick stainless steel sheets of 304

qualities. The internal of the dryer is built of 1.6 mm thick s.s 304 quality sheets insulated

with minimum 50 mm thick glass wool insulation and caddied with s,s, polished sheets.

Fresh air inlet through 20 micron pp cloth filters and a adjustable air outlet flap and a door at the front.

Explosion proof door is locked with the help of spring loaded ball latches with suitable pressure.

To prevent leakages door lips are having neoprene rubber gasket Finishing. Designed and manufactured as per GMP standard. Aesthetic look. Buffed externally to 150 grit matt finish. Internally buffed to 220 grit mirror finish Electrical heating. The heaters are fitted on the sides of the dryer to facilitate uniform heating. Maximum temperature attained inside the dryer is 100' C. The temperature is indicated and controlled by a Digital Temperature indicator

cum controller over full range of heating load.

120.DEVELOPMENT AND EVALUATION OF DEHYDRATED AND IRRADIATED JACKFRUIT (Artocarpus heterophyllus) PRODUCTS, Department of Food Science and Nutrition, AAU, Jorhat-13

Heat sealing machine

Vertical band sealing/ horizontal/ cup sealing Voltage V/Hz: AC 220/50 AC 110/60 Motor power (W) : 315 to 500 Heater power (W) 90x2 to 300x2 Printing heating power (W): 40x2 The Machine is suitable for sealing & packing of single, double & multilayer pouches. NP-1120 series machine is specially designed for vertical sealing. According to

different carrying load, such machine is divided into different model with maximum carrying load for single bag of 5kg respectively.

Moreover, it can also be equipped with solid-ink coding system for color printing. The height of head and conveyor both can be adjusted, so as to making widely using,

it also matches to operate with production line.

121.DEVELOPMENT AND EVALUATION OF DEHYDRATED AND IRRADIATED JACKFRUIT (Artocarpus heterophyllus) PRODUCTS, Department of Food Science and Nutrition, AAU, Jorhat-13

Digital refractometer

Wide measuring range: Brix 0-85% Refractive index 1.3200-1.5000 Data storage: Up to 1100 measurements results Data transfer to your computer by supplied software via infrared port. Can also

output via RS232C with RS converter for infrared (Option). Can display measurement results in Refractive Index (RI), Temperature compensated

RI, Brix % and the like. Automatic data saving and Automatic data output can be chosen. Three different sucrose conversion tables Brix and isomerized sugar HFCS42, HFCS55. Data can be converted to user-defined concentration and the unit can be used as a

concentration meter. Sample measurement: Either drip sample liquid onto the prism of RA-130 on a

desktop or dip the prism into sample liquid. Display contents: Refractive index, Temp. comp. RI, Brix, HFCS42, HFCS55 and

Temperature ( C/ F) Sample number, Data storage, Data output, Data deletion, Battery alarm.

Power source: DC 3V (2 x 1.5V alkaline AAA dry cells) Battery life: 60 hours (one measurement in one minute)

Page 39:  · Web viewASSAM AGRICULTURAL UNIVERSITY. Jorhat-785013. BIDDING DOCUMENT (Terms and conditions) 2-1 (41.3) /2009-10 /DRA (A) / 30226-34. Dtd: 04.02.2017. Directorate of Research

122.AICRPDA, BNCA, AAU

Flame photometer

Micro-controller based, For estimation of Na, K, Li, Ca and Ba with automatic ignition, automatic gas shut off and optional PC compatibility with RS 232C interface.Flame system- LPG & oil free dry air. Power requirement- 90-260 V AC. Accessories- filters for Na, K, Air compressor with buffer tank, 5cc beakers, cleaning wire and capillary and other accessories.

123.AICRPDA, BNCA, AAU

Zero Till Multi crop planter- Power tiller drawn

Rows: 4 rowsTractor HP: 10-15Row to row spacing: 8” and adjustableFertilizer metering: Agitator & sliding orifice typeSeed metering: Rotating disc with cells on periphery

124.AICRPDA, BNCA, AAU

Rice miller Sample Quantity: 150gm approx Timer: Provided with a timer Pressure time: 30-40 sec Operating Voltage: 220V, 50Hz AC Motor: ½ HP Size: 370 x 250 x 270 mm. (approx.) Weight: 24kg.

125.AICRPDA, BNCA, AAU

Digital grain vernier

Range : 0 to 12.7mm Accuracy : 0.01 mm Dimensions (approx) :145 mm x 75 mm (LXB) (approx) Weight : 304 gm (Approx) Stem Diameter :8mm

126.AICRPDA, BNCA, AAU

Soil Thermometer

5 cm and 10 cm