vinyl acetate ch co ch:ch no

1
Vinyl Acetate CH3CO2CH:CH2 No.143 10 20 40 60 80 100 ppm n=2 143 1 ppm4 pump strokesWhite Brown Temperature 0 to 40 (32 to 104 ) correction not used Relative humidity 0 to 90 % correction not used 15 % for 10 to 20 ppm, 10 % for 20 to 100 ppm10 tubes for 5 tests 36 months Detecting limit : Colour change : Operating conditions : Relative standard deviation : Tube quantity and number of tests per box : Shelf life : Performance 5 to 10 ppm 10 to 100 ppm 100 to 250 ppm 4400 mL2200 mL1100 mL1/2 1 2.5 2 min 1 min 30 sec Measuring range Number of pump strokes Correction factor Sampling time CH3CO2CH:CH2 C6H3 CH33 H2S2O7 Condensation polymer Reaction principle Diffusion tube method Calibration gas generation When used, these tubes are to be connected. See page 2-3. Possible coexisting substances and their interferences Aldehydes, Ketones Brown Etylene 1000 ppm Yellow Vinyl chloride 500 ppm Substance Concentration Interference Changes colour by itself to Scale

Upload: others

Post on 16-Feb-2022

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Vinyl Acetate CH CO CH:CH No

Vinyl Acetate CH3CO2CH:CH2 No.143

10 20 40 60 80 100

ppm

n=2

143

1 ppm(4 pump strokes)White → BrownTemperature 0 to 40 ℃ (32 to 104 ℉) correction not usedRelative humidity 0 to 90 % correction not used15 %(for 10 to 20 ppm), 10 %(for 20 to 100 ppm)10 tubes for 5 tests36 months

Detecting limit :Colour change :Operating conditions :

Relative standard deviation :Tube quantity and number of tests per box :Shelf life :

Performance

5 to 10 ppm 10 to 100 ppm 100 to 250 ppm 4(400 mL) 2(200 mL) 1(100 mL) 1/2 1 2.5 2 min 1 min 30 sec

Measuring rangeNumber of pump strokesCorrection factorSampling time

CH3CO2CH:CH2 + C6H3(CH3)3 + H2S2O7 → Condensation polymer Reaction principle

Diffusion tube methodCalibration gas generation

When used, these tubes are to be connected. See page 2-3.

Possible coexisting substances and their interferences

Aldehydes, Ketones + BrownEtylene ≧ 1000 ppm + YellowVinyl chloride ≧ 500 ppm +

Substance Concentration Interference Changes colour by itself to

Scale