VC 1.1
2020
7
2
8
1
4
3
5 6
9
A primary seal made of polyisobutylene is used for its high resistance against ultraviolet rays and is combined to a
secondary seal made of high quality silicone.
The tubular profile contains a highly effective drying agent, providing moisture-free air space between glass panels.
The unique hollow-chambered louvers provide maximum rigidity and strength and maintain the parallel alignment of
the blades for utmost privacy and light control.
The 2 1/2" (63.5mm) dehydrated airspace reduces noise, providing sound attenuation superior to insulating glass
units with standard airspaces. 2" (50.8mm) airspace available.
All pivots, pinions, and racks are made of u.v. stabilized material to ensure dimensional stability, durability, never
needing lubrication.
Various glazing products and polycarbonates are available according to applications and project needs.
The rack is made of corrosion-resistant aluminum.
The gear housing (for crank handles, knobs and motors) is mechanically attached to the frame.
The fingertip crank handles, thumbwheels and knobs operators are made of long-lasting plastic, zinc, brass or
aluminum, easy to rotate and requiring no maintenance.
1
2
3
4
5
6
7
8
9
VISION CONTROL
®
FEATURES
-
54mm
2 1/8''
57
.9
mm
2 9
/3
2''
B
1
B
STANDARD HEIGHT
1
B
2
B
NON-STANDARD HEIGHT
2
BB
NON-STANDARD HEIGHT
3
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 1.2.1
2020
VISION CONTROL
®
HANDLE / KNOB POSITION
25.6mm
1''
GEAR
HOUSING
17
.2
mm
11
/1
6''
50
.8
mm
2''
TYPICAL DETAIL TYPICAL DETAIL
BA
18.1mm
23/32''
54
mm
2 1
/8
''
9.5mm
3/8''
4.7
6m
m
3/1
6''
16
1.9
mm
6 3
/8
"
VA
RIE
S
16
6.7
mm
6 9
/1
6"
17
1.5
mm
6 3
/4
"
9.5
mm
3/8
''
REFER TO STANDARD GLASS SIZES FOR HEIGHTS ON PAGE VC 1.6
OPTIONAL OPERATORS:
LOUVERS BETWEEN INSULATING GLASS
MANUALLY OPERATED
OPTION : ELECTRICALLY OPERATED
A
B
(N
ON
-S
TA
ND
AR
D L
OC
AT
IO
N
FO
R O
PE
RA
TO
RS
A
VA
IL
AB
LE
)
AIR
S
PA
CE
* VISIBLE SEALANT
AT PERIMETER
3/4" (19.1mm) Ø
ALUMINUM KNOB
1" (25.4mm) Ø
ALUMINUM KNOB
FOLDABLE ZINC
CRANK HANDLE
(WHITE OR GRAY)
31/32'' (24.6mm) Ø
BRASS LIGATURE-RESISTANT KNOB
(PAINTED WHITE OR GRAY)
- WHITE K-1285
- GRAY K-20794
- CUSTOM COLORS
FOLDABLE ZINC
CRANK HANDLE
(WHITE OR GRAY)
ALUMINUM FINISH:
STANDARD DURACRON
- GLOSSY WHITE K-1285
- METALLIC GRAY K-20794
1 IN
CR
EM
EN
T
2 IN
CR
EM
EN
TS
-
63.5mm
2 1/2''
B
1
B
1
B
2
B
2
BB
3
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 1.2.2
2020
25.6mm
1''
17
.2
mm
11
/1
6''
50
.8
mm
2''
BA
18.1mm
23/32''
8.7mm
11/32''
1 IN
CR
ÉM
EN
T
4.7
6m
m
3/1
6''
18
7.3
mm
7 3
/8
"
2 IN
CR
ÉM
EN
TS
9.5
mm
3/8
''
A
B
19
2.1
mm
7 9
/1
6"
19
6.9
mm
7 3
/4
"
AIR
S
PA
CE
STANDARD HEIGHTNON-STANDARD HEIGHT NON-STANDARD HEIGHT
VISION CONTROL
®
THUMBWHEEL POSITION
TYPICAL DETAIL TYPICAL DETAIL
ALUMINUM FINISH:
STANDARD DURACRON
- GLOSSY WHITE K-1285
- METALLIC GRAY K-20794
* SEALANT REVEAL
AT PERIMETER
VA
RIE
S
VA
RIE
S
REFER TO STANDARD GLASS SIZES FOR HEIGHTS ON PAGE VC 1.6
LOUVERS BETWEEN INSULATING GLASS
MANUALLY OPERATED
OPTION : ELECTRICALLY OPERATED
(N
ON
-S
TA
ND
AR
D L
OC
AT
IO
N
FO
R O
PE
RA
TO
RS
A
VA
IL
AB
LE
)
OPTIONAL OPERATORS:
FAN-SHAPED THUMBWHEEL OPERATOR
(VARIABLE DIAMETER)
- WHITE ALUMINUM
- GRAY ALUMINUM
- BLACK POLYMER
FULL THUMBWHEEL OPERATOR
(VARIABLE DIAMETER)
- WHITE ALUMINUM
- GRAY ALUMINUM
- BLACK POLYMER
-
48 in. = 1.219 m
1219mm
48''
5810 in.
2
= 3.75 m
2
1473mm
58''
1727mm
68''
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 1.3
50.8mm
2''
50.8mm
2''
50.8mm
2''
58 in. = 1.473 m4640 in.
2
= 2.99 m
2
68 in. = 1.727 m4080 in.
2
= 2.63 m
2
6.4
mm
1/4
''
9.5
mm
3/8
''
12.7
mm
1/2
''
35.6m
m
1 13/32''
33
.3
mm
1 5
/1
6''
35.6m
m
1 13/32''
33
.3
mm
1 5
/1
6''
35.6m
m
1 13/32''
33
.3
mm
1 5
/1
6''
63.5mm
2 1/2''
2020
3 3/4 in. = 95.3 mm 3 3/4 in. = 95.3 mm 3 3/4 in. = 95.3 mm
MAXIMUM AREA MAXIMUM WIDTH MAXIMUM AREA MAXIMUM WIDTH
MAXIMUM GLASS SIZE
MAXIMUM AREA MAXIMUM WIDTH
VISION CONTROL
®
BLADE TYPES, AIRSPACES AND
MINIMUM / MAXIMUM SIZES
- VISION CONTROL
®
GLASS PANELS ARE MADE WITH INTERLOCKING BLADES,
OFFERING TOTAL PRIVACY AND OPTIMAL LIGHT CONTROL WHEN CLOSED.
- GLASS SIZE LIMITATIONS AND THICKNESSES TO BE DETERMINED BY UNICEL'S ENGINEERING DEPARTMENT.
- TWO AIRSPACE THICKNESSES ARE AVAILABLE: 2" AND 2 1/2" (50.8mm AND 63.5mm)
- THREE BLADE THICKNESSES ARE AVAILABLE: 1/4", 3/8" AND 1/2" (6.4mm, 9.5mm AND 12.7mm)
* If required sizes are outside of feasibility range, please contact Unicel for special arrangements.
MAX. WIDTH
MAXIMUM GLASS SIZEMAXIMUM GLASS SIZE
MAX. WIDTH MAX. WIDTH
OPTIONAL SPACER:
MINIMUM WIDTH
MINIMUM GLASS SIZE
MINIMUM WIDTH
MINIMUM GLASS SIZE
MINIMUM WIDTH
MINIMUM GLASS SIZE
-
20.6mm
13/16''
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 1.4
96" (2438mm)
116" (2946mm)
136" (3454mm)
1/4" (6.4mm)
3/8" (9.5mm)
1/2" (12.7mm)
12.7mm
1/2''
2020
12.7mm
1/2''
MAXIMUM GLASS WIDTH
VISION CONTROL
®
DOUBLE PANELS
MAXIMUM GLASS WIDTH BLADE TYPE
CLEARANCE
REQUIRED
CLEARANCE
REQUIRED
MIDDLE INNER
SPACER
VISION CONTROL
®
PANEL
GEAR HOUSING
2 1/8'' x 2 9/32''
(54mm x 57.9mm)
FOLDABLE ZINC
CRANK HANDLE
DETAIL
ELEVATION
MIDDLE INNER SPACER FOR INTERMEDIATE LOUVER SUPPORT
-
A
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 1.5
2020
53.2mm
50
.8
mm
2''
39.4mm
1 9/16''
2 3/32''
A
A
TYPICAL DETAIL
RIGHT-ANGLED TRIANGLE TRAPEZOIDAL
GEAR HOUSING
2 1/8'' X 2 9/32''
(54mm X 57.9mm)
VISION CONTROL
®
RIGHT-ANGLED TRIANGLE
AND TRAPEZOIDAL SHAPE
-
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 1.6
2020
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
1376.4
1409.7
1443.0
1476.4
1509.7
1543.1
1576.4
1609.7
1643.1
1676.4
1709.7
1743.1
1776.4
1809.8
1843.1
1876.4
1909.8
1943.1
1976.4
2009.8
2043.1
2076.5
2109.8
2143.1
2176.5
2209.8
2243.1
2276.5
2309.8
2343.2
2376.5
2409.8
2443.2
2476.5
2509.8
2543.2
2576.5
54 3/16
55 1/2
56 13/16
58 1/8
59 7/16
60 3/4
62 1/16
63 3/8
64 11/16
66
67 5/16
68 5/8
69 15/16
71 1/4
72 9/16
73 7/8
75 3/16
76 1/2
77 13/16
79 1/8
80 7/16
81 3/4
83 1/16
84 3/8
85 11/16
87
88 5/16
89 5/8
90 15/16
92 1/4
93 9/16
94 7/8
96 3/16
97 1/2
98 13/16
100 1/8
101 7/16
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
2609.9
2643.2
2676.5
2709.9
2743.2
2776.5
2809.9
2843.2
2876.6
2909.9
2943.2
2976.6
3009.9
3043.2
3076.6
3109.9
3143.3
3176.6
3209.9
3243.3
3276.6
3309.9
3343.3
3376.6
3410.0
3443.3
3476.6
3510.0
3543.3
3576.6
3610.0
3643.3
3676.7
3710.0
3743.3
3776.7
3810.0
102 3/4
104 1/16
105 3/8
106 11/16
108
109 5/16
110 5/8
111 15/16
113 1/4
114 9/16
115 7/8
117 3/16
118 1/2
119 13/16
121 1/8
122 7/16
123 3/4
125 1/16
126 3/8
127 11/16
129
130 5/16
131 5/8
132 15/16
134 1/4
135 9/16
136 7/8
138 3/16
139 1/2
140 13/16
142 1/8
143 7/16
144 3/4
146 1/16
147 3/8
148 11/16
150
142.9
176.2
209.6
242.9
276.2
309.6
342.9
376.2
409.6
442.9
476.3
509.6
542.9
576.3
609.6
642.9
676.3
709.6
743.0
776.3
809.6
843.0
876.3
909.6
943.0
976.3
1009.7
1043.0
1076.3
1109.7
1143.0
1176.3
1209.7
1243.0
1276.4
1309.7
1343.0
5 5/8
6 15/16
8 1/4
9 9/16
10 7/8
12 3/16
13 1/2
14 13/16
16 1/8
17 7/16
18 3/4
20 1/16
21 3/8
22 11/16
24
25 5/16
26 5/8
27 15/16
29 1/4
30 9/16
31 7/8
33 3/16
34 1/2
35 13/16
37 1/8
38 7/16
39 3/4
41 1/16
42 3/8
43 11/16
45
46 5/16
47 5/8
48 15/16
50 1/4
51 9/16
52 7/8
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
METRIC (mm)IMPERIAL (")# BLADES METRIC (mm)IMPERIAL (")# BLADES # BLADES METRIC (mm)IMPERIAL (")
VISION CONTROL
®
HEIGHT CHART
STANDARD GLASS SIZES FOR HEIGHTS*
(FOR HORIZONTAL LOUVERS ONLY)**
*NON-STANDARD GLASS HEIGHTS ARE ALSO AVAILABLE BY ADDING SERIES OF 3/16"(4.76mm) INCREMENTS TO ANY GIVEN STANDARD HEIGHT (SEE PAGE VC 1.2.1 & 1.2.2)
**FOR VERTICAL LOUVERS, THIS CHART CAN BE INTERPRETED AS STANDARD GLASS SIZES FOR WIDTHS
-
50.8mm
2''
X YX Y
X Y
63.5mm
2 1/2''
63.5mm
2 1/2''
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 1.7
2020
50.8mm
2''
X Y
1/4" (6mm) 2" (50.8mm) 1/4" (6mm) 41
1/4" (6mm) 2 1/2" (63.5mm) 42
1/4" (6mm) 45
1/4" (6mm) 46
3/8" (10mm) 48
1/8" - .060" PVB - 1/8" (3mm - 1.6mm PVB - 3mm) 50
1/8" - .060" PVB - 1/8" (3mm - 1.6mm PVB - 3mm) 51
2" (50.8mm)
2" (50.8mm)
2" (50.8mm)
2" (50.8mm)
2 1/2" (63.5mm)
1/4" (6mm)
1/8" - .060" PVB - 1/8" (3mm - 1.6mm PVB - 3mm)
3/16" - .060" PVB - 3/16" (5mm - 1.6mm PVB - 5mm)
1/4" - .060" PVB - 1/4" (6mm - 1.6mm PVB - 6mm)
1/8" - .060" PVB - 1/8" (3mm - 1.6mm PVB - 3mm)
1/8" - .060" PVB - 1/8" (3mm - 1.6mm PVB - 3mm)
NOTE:
ALL DATA SHOULD BE VERIFIED VIA TESTING THE ACTUAL WINDOW ASSEMBLY TO ASCERTAIN THE EFFECTS OF WINDOW FRAMES ON TOTAL WINDOW SYSTEM SOUND TRANSMISSION LOSS.
ALL DATA WERE ESTIMATED (DERIVED FROM TESTED SAMPLES COMPARABLE IN CONFIGURATION TO THOSE ABOVE) AND ARE NOT GUARANTEED FOR ALL SAMPLES OR APPLICATIONS.
VISION CONTROL
®
ACOUSTICAL GLAZING
SOUND CONTROL GLASS
VISION CONTROL
®
IS AVAILABLE WITH VARIOUS GLASS TYPES AND THICKNESSES WITH THE OPTION
OF 2" (50.8mm) OR 2 1/2" (63.5mm) AIRSPACE, OFFERING EXCEPTIONAL SOUND DAMPING CHARACTERISTICS.
IGU AVAILABLE
WITHOUT BLADES
EXAMPLES OF STC RATINGS WITH VARYING GLASS CONFIGURATIONS
GLASS LITE X AIRSPACE GLASS LITE Y STC (ESTIMATED)
-
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 1.8
2020
17.5mm
11/16"
81mm
3 3/16"
17.5mm
11/16"
76.2mm
3"
= =
12
.7
mm
1/2
"
7.9mm
5/16"
7.9mm
5/16"
7.9
mm
5/1
6"
6.4
mm
1/4
"
3.2
mm
1/8
"
1/4
"
6m
m
1 19/32"
40mm
15
.9
mm
5/8
"
12
.7
mm
1/2
"
A A
4
8
"
-
9
6
"
1
2
1
9
.
2
m
m
-
2
4
3
8
.
4
m
m
19.1mm
3/4"
28
.6
mm
1 1
/8
"
VISION CONTROL
®
ACCESSORIES
GLASS STOPS THUMBWHEEL COVER
HOLE(2) 9/64" (3.6mm) Ø COUNTERSINK (HS #4)
SCREW #6 X 3/4" (19.1mm)
STAINLESS STEEL PHILLIPS OVAL HEAD
EXTENSION POLE
HEXAGONAL SOCKET
EXTENSION POLE
FOR OUT-OF-REACH VISION CONTROL
®
UNITS
VISION CONTROL
®
PANEL
HEXAGONAL
SOCKET
OVAL PLATE
OVAL PLATE
SNAP-ON COVER
STANDARD FINISHES*
DURACRON WHITE K-1285
DURACRON GRAY K-20794
CLEAR ANODIZED (CLASS II)
GLASS STOPS
* OTHER FINISHES AVAILABLE UPON REQUEST.
25.4mm
1"
44
.5
mm
1 3
/4
"
25.4mm
1"
44
.5
mm
1 3
/4
"
PSYCHIATRIC
APPLICATION
-
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 2.1.1
2020
AC
B
C
A B
50
.8
mm
2''
63.5mm
2 1/2''
28
.6
mm
1 1
/8
''
1.6mm
1/16''
1.6mm
1/16''
19.1mm
3/4''
12
.7
mm
1/2
''
16
1.9
mm
6 3
/8
''
28.6mm
1 1/8''
12.7mm
1/2''
19
.1
mm
3/4
''
63
.5
mm
2 1
/2
''
1.6
mm
1/1
6''
1.6
mm
1/1
6''
12.7mm
1/2''
12
.7
mm
1/2
''
16
1.9
mm
6 3
/8
''
50
.8
mm
2''
25.4mm
1''
28
.6
mm
1 1
/8
''
SETTING BLOCK
BY OTHERS
STEEL FRAME
BY OTHERS
ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL
ALUMINUM
BLOCK
GEAR HOUSING
ALUMINUM
BLOCK
FOLDABLE ZINC
CRANK HANDLE
(OPTIONAL)
ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL
CLEARANCE
REQUIRED
GEAR
HOUSING
FOLDABLE ZINC
CRANK HANDLE
VISION CONTROL
®
PANEL
ALUMINUM BLOCK
ALUMINUM
GLASS STOPS
BY UNICEL
SETTING BLOCK
BY OTHERS
OVAL PLATE
VISION CONTROL
®
INTERIOR WALL
HOLLOW METAL FRAME
CRANK HANDLE OPERABLE ON ONE OR BOTH SIDE(S)
STANDARD FINISHES*
DURACRON WHITE K-1285
DURACRON GRAY K-20794
CLEAR ANODIZED (CLASS II)
LOUVERS GLASS STOPS
* OTHER FINISHES AVAILABLE UPON REQUEST.
VISION CONTROL
®
PANEL
FOLDABLE ZINC
CRANK HANDLE
FOLDABLE ZINC
CRANK HANDLE
FOLDABLE ZINC
CRANK HANDLE
(OPTIONAL)
-
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 2.1.2
2020
A A
B B
28.6mm
1 1/8''
9.5mm
3/8''
63
.5
mm
2 1
/2
''
9.5
mm
3/8
''
19
.1
mm
3/4
''
A
B
28.6mm
1 1/8''
9.5mm
3/8''
50
.8
mm
2''
9.5
mm
3/8
''
19
.1
mm
3/4
''
50.8mm
2''
28
.6
mm
1 1
/8
''
12
.7
mm
1/2
''
18
7.3
mm
7 3
/8
''
19.1mm
3/4''
50.8mm
2''
19.1mm
3/4''
9.5mm
3/8''
28
.6
mm
1 1
/8
''
12
.7
mm
1/2
''
18
7.3
mm
7 3
/8
''
9.5mm
3/8''
9.5mm
3/8''
9.5mm
3/8''
9.5mm
3/8''
VISION CONTROL
®
INTERIOR WALL
HOLLOW METAL FRAME
THUMBWHEEL OPERABLE ON ONE OR BOTH SIDE(S)
ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL
CLEARANCE
REQUIRED
VISION CONTROL
®
PANEL
CLEARANCE
REQUIRED
SETTING BLOCK
BY OTHERS
STEEL FRAME
BY OTHERS
ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL
FULL THUMBWHEEL
OPERATOR
(VARIABLE DIAMETER)
CU
T-O
UT
CU
T-O
UT
CU
T-O
UT
CU
T-O
UT
ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL
VISION CONTROL
®
PANEL
ACCESSIBLE ON BOTH SIDES ACCESSIBLE ON ONE SIDE
SETTING BLOCK
BY OTHERS
STEEL FRAME
BY OTHERS
ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL
FAN-SHAPED
THUMBWHEEL OPERATOR
(VARIABLE DIAMETER)
CU
T-O
UT
CU
T-O
UT
FAN-SHAPED
THUMBWHEEL OPERATOR
(VARIABLE DIAMETER)
STANDARD FINISHES*
DURACRON WHITE K-1285
DURACRON GRAY K-20794
CLEAR ANODIZED (CLASS II)
LOUVERS GLASS STOPS
* OTHER FINISHES AVAILABLE UPON REQUEST.
FULL THUMBWHEEL OPERATOR
(VARIABLE DIAMETER)
± 115°
NOTE:
ROTATION LIMITED TO
APPROX. 115° INSTEAD OF 180°
LOUVERS COME DOWN
FROM OPERABLE SIDE
-
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 2.1.3
2020
A B
DC
1.6mm
1/16''
50.8mm
2''
1.6mm
1/16''
25.4mm
1''
16
1.9
mm
6 3
/8
''
50
.8
mm
2''
12
.7
mm
1/2
''
28
.6
mm
1 1
/8
''
50.8mm
2''
1.6mm
1/16''
1.6mm
1/16''
25.4mm
1''
12
.7
mm
1/2
''
28
.6
mm
1 1
/8
''
50
.8
mm
2''
25.4mm
1''
16
1.9
mm
6 3
/8
''
50
.8
mm
2''
12
.7
mm
1/2
''
28
.6
mm
1 1
/8
''
C
50.8mm
2''
1.6mm
1/16''
1.6mm
1/16''
50.8mm
2''
1.6mm
1/16''
1.6mm
1/16''
25.4mm
1''
12
.7
mm
1/2
''
28
.6
mm
1 1
/8
''
B
D
16
1.9
mm
6 3
/8
''
SETTING BLOCK
BY OTHERS
X-RAY SHIELDING
LEAD GLASS
VISION CONTROL
®
PANEL
LEAD LINING
BY OTHERS
ALUMINUM BLOCK
UN
IC
EL
RE
CO
MM
EN
DS
STEEL FRAME &
GLASS STOPS
BY OTHERS
VISION CONTROL
®
PANEL
3/8" (10mm)
POLYCARBONATE
SETTING BLOCK
BY OTHERS
ALUMINUM BLOCK
DETAIL - INTERIOR
X-RAY SHIELDING
FOLDABLE REMOVABLE
ZINC CRANK HANDLE
UN
IC
EL
RE
CO
MM
EN
DS
SETTING BLOCK
BY OTHERS
PYROSTOP
FIRE-RATED
GLASS (45 MIN;
60 MIN; 90 MIN)
VISION CONTROL
®
PANEL
ALUMINUM BLOCK
FIRE-RATED
STEEL FRAME &
GLASS STOPS
BY OTHERS
UN
IC
EL
RE
CO
MM
EN
DS
DETAIL - INTERIOR
FIRE-RATED
VARIES
SETTING BLOCK
BY OTHERS
VISION CONTROL
®
PANEL
ALUMINUM
BLOCK
STEEL FRAME &
GLASS STOPS
BY OTHERS
UN
IC
EL
RE
CO
MM
EN
DS
STEEL FRAME &
GLASS STOPS
BY OTHERS
HEXAGONAL
SOCKET
DETAIL - INTERIOR
POLYCARBONATE
DETAIL - INTERIOR
VERTICAL LOUVERS
VISION CONTROL
®
INTERIOR WALL
HOLLOW METAL FRAMES
FOLDABLE ZINC
CRANK HANDLE
(REFER TO PAGE VC 1.2.1
FOR OPTIONAL OPERATORS)
FOLDABLE ZINC
CRANK HANDLE
(REFER TO PAGE VC 1.2.1
FOR OPTIONAL OPERATORS)
FOLDABLE ZINC
CRANK HANDLE
(REFER TO PAGE VC 1.2.1
FOR OPTIONAL OPERATORS)
A
VARIABLE
MIN
. 1
2.7
mm
1/2
"
-
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 2.1.4
2020
E F
HG
50.8mm
2''
18
7.3
mm
7 3
/8
''
19.1mm
3/4''
9.5mm
3/8''
127mm OR 152.4mm
5" OR 6"
12
.7
mm
1/2
''
50.8mm
2''
18
7.3
mm
7 3
/8
''
19.1mm
3/4''
9.5mm
3/8''
12
.7
mm
1/2
''
44
.5
mm
1 3
/4
''
1.6mm
1/16''
1.6mm
1/16''
50
.8
mm
2''
16
1.9
mm
6 3
/8
''
50.8mm
2''
25.4mm
1''
12
.7
mm
1/2
''
50.8mm
2''
44
.4
mm
1 3
/4
''
28
.6
mm
1 1
/8
''
19.1mm
3/4''
19.1mm
3/4''
5" OR 6"
127mm OR 152.4mm
19.1mm
3/4''
12
.7
mm
1/2
''
28
.6
mm
1 1
/8
''
1.6mm
1/16''
44
.5
mm
1 3
/4
''
16
1.9
mm
6 3
/8
''
50
.8
mm
2''
28
.6
mm
1 1
/8
''
28
.6
mm
1 1
/8
''
6.4
mm
1/4
''
E F
G H
6.4
mm
1/4
''
FULL THUMBWHEEL
OPERATOR
(VARIABLE DIAMETER)
SETTING BLOCK
BY OTHERS
VISION CONTROL
®
PANEL
ALUMINUM FRAME &
GLASS STOPS
BY UNICEL
SETTING BLOCK
BY OTHERS
FAN-SHAPED
THUMBWHEEL OPERATOR
(VARIABLE DIAMETER)
VISION CONTROL
®
PANEL
ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL
WOOD FRAME
BY OTHERS
ALUMINUM
SNAP-ON
GLASS STOPS
BY UNICEL
SETTING BLOCK
BY OTHERS
VISION CONTROL
®
PANEL
STEEL FRAME
BY OTHERS
ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL
ALUMINUM
BLOCK
SETTING BLOCK
BY OTHERS
VISION CONTROL
®
PANEL
ALUMINUM FRAME
& GLASS STOPS
BY UNICEL
ALUMINUM
BLOCK
FOLDABLE ZINC
CRANK HANDLE
(REFER TO PAGE VC 1.2.1
FOR OPTIONAL OPERATORS)
CU
T-O
UT
CU
T-O
UT
CU
T-O
UT
CU
T-O
UT
VISION CONTROL
®
INTERIOR WALL
VARIOUS FRAMES
CU
T-O
UT
CU
T-O
UT
FOLDABLE ZINC
CRANK HANDLE
(REFER TO PAGE VC 1.2.1
FOR OPTIONAL OPERATORS)
DETAIL - INTERIOR DETAIL - INTERIOR
WOOD FRAME
DETAIL - INTERIORDETAIL - INTERIOR
FRAME BY UNICEL RABETTED FRAME
FRAME BY UNICEL
± 115°
NOTE:
ROTATION LIMITED TO
APPROX. 115° INSTEAD OF 180°
LOUVERS COME DOWN
FROM OPERABLE SIDE
-
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 2.1.5
2020
9.5mm
3/8''
50.8mm
2''
1.6mm
1/16''
19.1mm
3/4''
1.6mm
1/16''
19.1mm
3/4''
9.5mm
3/8''
50.8mm
2''
12
.7
mm
1/2
''
28.6mm
1 1/8''
18
7.3
mm
7 3
/8
''
9.5mm
3/8''
28
.6
mm
1 1
/8
''
B
A
BA
28
.6
mm
1 1
/8
''
VISION CONTROL
®
INTERIOR WALL
SOUND OR SMOKE BARRIER
FAN-SHAPED
THUMBWHEEL
(VARIABLE DIAMETER)
FAN-SHAPED
THUMBWHEEL
(VARIABLE DIAMETER)
SOUND OR
SMOKE BARRIER
BY OTHERS
VISION CONTROL
®
PANEL
STEEL FRAME
BY OTHERS
SETTING BLOCK
BY OTHERS
ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL
DETAIL DETAIL
SOUND OR
SMOKE BARRIER
BY OTHERS
STANDARD FINISHES*
DURACRON WHITE K-1285
DURACRON GRAY K-20794
CLEAR ANODIZED (CLASS II)
LOUVERS GLASS STOPS
* OTHER FINISHES AVAILABLE UPON REQUEST.
DOUBLE FAN-SHAPED THUMBWHEEL OPERABLE ON BOTH SIDES
± 115°
NOTE:
ROTATION LIMITED TO
APPROX. 115° INSTEAD OF 180°
LOUVERS COME DOWN
FROM OPERABLE SIDE
NOTE:
ROTATION LIMITED TO
APPROX. 115° INSTEAD OF 180°
LOUVERS COME UP
FROM OPERABLE SIDE
± 115°
VA
RIE
S
-
C
B
A
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 2.1.6
A
2020
VISION CONTROL
®
INTERIOR WALL
CORNER CONFIGURATIONS
INTERIOR
DETAIL
BUTT-GLAZED WITH CORNER BRAKE METAL
9.5mm
3/8''
9.5
mm
3/8
''
19
.1
mm
3/4
''
19
.1
mm
3/4
''
63
.5
mm
2 1
/2
''
19.1mm
3/4''
19.1mm
3/4''
63.5mm
2 1/2''
33
.4
mm
1 5
/1
6''
1.6
mm
1/1
6''
1.6
mm
1/1
6''
91.4mm
3 19/32''
17
mm
21
/3
2''
22
.7
mm
29
/3
2''
5.2mm
7/32''
3.2mm
1/8''
12.1mm
15/32''
9
0
°
1.6mm
1/16''
1.6mm
1/16''
9.5mm
3/8''
9.5
mm
3/8
''
FAN-SHAPED THUMBWHEEL OPERATOR ACCESSIBLE ON
ONE SIDE ONLY (VARIABLE DIAMETER)
ALSO AVAILABLE: FULL THUMBWHEEL OPERATOR
ACCESSIBLE ON BOTH SIDES
CLEARANCE
REQUIRED
VISION CONTROL
®
PANEL
ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL
HOLLOW METAL
FRAME BY OTHERS
OUTSIDE & INSIDE
0.080" (2mm)
THICK BREAK METAL
CLOSURE BY UNICEL
GLAZING TAPE
BY OTHERS
3M TAPE 1/16" (1.6mm)
TYPICAL
BY OTHERS
VIEW
90° ANGLE
FINITIONS STANDARD* BREAK METALGLASS STOPS
DURACRON WHITE K-1285
DURACRON GRAY K-20794
CLEAR ANODIZED (CLASS II)
LOUVERS
* OTHER FINISHES AVAILABLE UPON REQUEST.
-
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 2.1.7
2020
VISION CONTROL
®
INTERIOR WALL
CORNER CONFIGURATIONS
INTERIOR
DETAIL
BUTT-GLAZED WITH CORNER BRAKE METAL
B
19
.1
mm
3/4
''
19
.1
mm
3/4
''
63
.5
mm
2 1
/2
''
19.1mm
3/4''
19.1mm
3/4''
63.5mm
2 1/2''
9
0
°
12.7mm
1/2''
28
.6
mm
1 1
/8
''
9.5mm
3/8''
9.5
mm
3/8
''
19
.1
mm
3/4
''
19
.1
mm
3/4
''
63
.5
mm
2 1
/2
''
9.5
mm
3/8
''
28
.6
mm
1 1
/8
''
INTERIOR
DETAIL
BUTT-GLAZED WITHOUT CORNER BRAKE METAL
VIEW
VISION CONTROL
®
PANEL
HOLLOW METAL
FRAME BY OTHERS
GLAZING TAPE
BY OTHERS
FOLDABLE ZINC
CRANK HANDLE
(OPTIONAL)
GEAR HOUSING
FOLDABLE ZINC CRANK HANDLE
(REFER TO PAGE VC 1.2.1
FOR OPTIONAL OPERATORS)
CERAMIC FRIT ON
INSIDE FACE OF GLASS
(COLOR TO BE DETERMINED)
SILICONE JOINTS ON
CORNER GLASS
BY OTHERS
ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL
CLEARANCE
REQUIRED
9
0
°
C
VISION CONTROL
®
PANEL
ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL
GLAZING TAPE
BY OTHERS
CLEARANCE
REQUIRED
HOLLOW METAL
FRAME BY OTHERS
ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL
HOLLOW METAL
FRAME BY OTHERS
FULL THUMBWHEEL
OPERATOR ACCESSIBLE ON BOTH SIDES
(VARIABLE DIAMETER)
ALSO AVAILABLE: FAN-SHAPED THUMBWHEEL
OPERATOR ACCESSIBLE ON ONE SIDE
19.1mm
3/4''
19.1mm
3/4''
63.5mm
2 1/2''
-
C
B
A
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 2.1.8
9.5mm
3/8''
A
9.5mm
3/8''
9.5
mm
3/8
''
19
.1
mm
3/4
''
19
.1
mm
3/4
''
63
.5
mm
2 1
/2
''
2
8
.
6
m
m
1
1
/
8
'
'
2020
VISION CONTROL
®
INTERIOR WALL
CORNER CONFIGURATIONS
VARIES
VARIES
V
A
R
I
E
S
V
A
R
I
E
S
V
A
R
I
E
S
HOLLOW METAL
FRAME BY OTHERS
OUTSIDE & INSIDE 0.080" (2mm)
THICK BREAK METAL CLOSURE
BY UNICEL
RIGID INSULATOR
(IF REQUIRED)
BY OTHERS
3M TAPE 1/16" (1.6mm) TYPICAL
BY OTHERS
VISION CONTROL
®
PANEL
ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL
GLAZING TAPE
BY OTHERS
FAN-SHAPED THUMBWHEEL OPERATOR
ACCESSIBLE ON ONE SIDE ONLY
(VARIABLE DIAMETER)
ALSO AVAILABLE: FULL THUMBWHEEL
OPERATOR ACCESSIBLE ON BOTH SIDES
VIEW
INTERIOR
DETAIL
BUTT-GLAZED WITH CORNER BRAKE METAL
CLEARANCE
REQUIRED
VARIABLE ANGLE
FINITIONS STANDARD* BREAK METALGLASS STOPS
DURACRON WHITE K-1285
DURACRON GRAY K-20794
CLEAR ANODIZED (CLASS II)
LOUVERS
* OTHER FINISHES AVAILABLE UPON REQUEST.
-
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 2.1.9
1
2
.
7
m
m
1
/
2
'
'
12.7mm
1/2''
9.5mm
3/8''
9.5
mm
3/8
''
B
C
19
.1
mm
3/4
''
19
.1
mm
3/4
''
63
.5
mm
2 1
/2
''
19
.1
mm
3/4
''
19
.1
mm
3/4
''
63
.5
mm
2 1
/2
''
2
8
.
6
m
m
1
1
/
8
'
'
2
8
.
6
m
m
1
1
/
8
'
'
9.5
mm
3/8
''
2020
VISION CONTROL
®
INTERIOR WALL
CORNER CONFIGURATIONS
V
A
R
I
E
S
HOLLOW METAL FRAME
BY OTHERS
VISION CONTROL
®
PANEL
ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL
GLAZING TAPE
BY OTHERSCERAMIC FRIT ON
INSIDE FACE OF GLASS
(COLOR TO BE DETERMINED)
SILICONE JOINTS ON
CORNER GLASS
BY OTHERS
HOLLOW METAL FRAME
BY OTHERS
HOLLOW METAL FRAME
BY OTHERS
VISION CONTROL
®
PANEL
ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL
GLAZING TAPE
BY OTHERS
FULL THUMBWHEEL
OPERATOR ACCESSIBLE ON BOTH SIDES
(VARIABLE DIAMETER)
ALSO AVAILABLE: FAN-SHAPED THUMBWHEEL
OPERATOR ACCESSIBLE ON ONE SIDE
VIEW
VIEW
INTERIOR
DETAIL
INTERIOR
DETAIL
CLEARANCE
REQUIRED
CORNER POST
BUTT-GLAZED WITHOUT CORNER BRAKE METAL
GEAR HOUSING
CLEARANCE
REQUIRED
FOLDABLE ZINC
CRANK HANDLE
(OPTIONAL)
FOLDABLE ZINC
CRANK HANDLE
(REFER TO PAGE VC 1.2.1
FOR OPTIONAL OPERATORS)
V
A
R
I
E
S
-
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 2.2.1
B
A
B
A
12
.7
mm
1/2
''
16
1.8
mm
6 3
/8
''
50.8mm
2''
1.6mm
1/16''
2.8mm
1/8''
15
.7
mm
5/8
''
16
1.8
mm
6 3
/8
''
50.8mm
2''
28
.6
mm
1 1
/8
''
33
.4
mm
1 5
/1
6''
2020
50
.8
mm
2''
VISION CONTROL
®
EXTERIOR WALL
VARIOUS FRAMES
EXTERIOR
DETAIL
EXTERIOR
DETAIL
OVAL PLATE
VISION CONTROL
®
PANEL
ALUMINUM
BLOCK
ALUMINUM FRAME
BY OTHERS
SETTING BLOCK
FLYSCREEN
ALUMINUM WINDOW FRAME
OPENING INWARDS
BY UNICEL
VISION CONTROL
®
PANEL
SETTING BLOCK
OPERABLE WINDOW
STOREFRONT SYSTEM
UNIVERSAL
L-ANGLE TRIM
BY UNICEL
FOLDABLE ZINC
CRANK HANDLE
(REFER TO PAGE VC 1.2.1
FOR OPTIONAL OPERATORS)
FOLDABLE ZINC
CRANK HANDLE
(REFER TO PAGE VC 1.2.1
FOR OPTIONAL OPERATORS)
ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL
PRESSURE PLATES AND
SNAP-ON COVERS BY UNICEL
-
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 2.2.2
28
.6
mm
1 1
/8
''
50.8mm
2''
19.1mm
3/4''
16
1.9
mm
6 3
/8
''
C
E
C D
25
.4
mm
1''
16
1.9
mm
6 3
/8
''
50.8mm
2''
6mm
1/4''
6mm
1/4''
E
6mm
1/4''
19.1mm
3/4''
28
.6
mm
1 1
/8
''
9.5mm
3/8''
63.5mm
2 1/2''
3.2mm
1/8''
18
7.3
mm
7 3
/8
"
12
.7
mm
1/2
''
63
.5
mm
2 1
/2
''
D
50.8m
m
2''
105.5mm
4 5/32''
25.4mm
1''
3.2
mm
1/8
''
50
.8
mm
2''
25.4mm
1''
2020
EXTERIOR
DETAIL
VISION CONTROL
®
EXTERIOR WALL
VARIOUS FRAMES
ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL
VISION CONTROL
®
PANEL
EXTERIOR
DETAIL
FAN-SHAPED
THUMBWHEEL OPERATOR
(VARIABLE DIAMETER)
VISION CONTROL
®
PANEL
BRASS LIGATURE-RESISTANT KNOB
(REFER TO PAGE VC 1.2.1
FOR OPTIONAL OPERATORS)
ROUND PLATE
1/4" (6mm) CLEAR
POLYCARBONATE
1/4" (6mm) CLEAR
TEMPERED GLASS
1/4" (6mm) CLEAR
TEMPERED GLASS WITH
SOFT-COAT LOW-E #2
ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL
CURTAIN WALL SYSTEMS
BY UNICEL OR BY OTHERS
SETTING BLOCKS
BY OTHERS
GEAR HOUSING
ALUMINUM BLOCK
EXTERIOR
DETAIL
EXISTING CURTAIN WALL SYSTEM CURTAIN WALL ADAPTER
OFFSET TRIPLE GLAZED
OVAL
PLATE
ALUMINUM
BLOCK
SETTING BLOCK
BY OTHERS
CURTAIN WALL
SYSTEMS BY
UNICEL OR
BY OTHERS
CURTAIN WALL SYSTEMS
BY UNICEL OR BY OTHERS
CURTAIN WALL ADAPTER
(FACTORY-GLAZED)
FOLDABLE ZINC
CRANK HANDLE
(REFER TO PAGE VC 1.2.1
FOR OPTIONAL OPERATORS)
± 115°
NOTE:
ROTATION LIMITED TO
APPROX. 115° INSTEAD OF 180°
LOUVERS COME DOWN
FROM OPERABLE SIDE
-
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 2.2.3
2020
F
25.4mm
1''
82.5mm
3 1/4''
6.4mm
1/4''
45.3mm
1 25/32''
16
1.9
mm
6 3
/8
''
44
.4
mm
1 3
/4
''
6.4
mm
1/4
''
6.3mm
1/4''
25.4mm
1''
6.4mm
1/4''
7.7mm
5/16''
F
G
16
1.9
mm
6 3
/8
''
63.5mm
2 1/2''
6mm
1/4''
12.5mm
1/2''
G
VISION CONTROL
®
EXTERIOR WALL
PSYCHIATRIC APPLICATION
CURTAIN WALL
EXISTING WALL
EXTERIOR
DETAIL
SETTING BLOCK BY OTHERS
NORTON TAPE THERMALBOND
1/4" X 3/4"
STRUCTURAL SILICONE JOINT
GEAR HOUSING
1/2" (12.7mm)1/4" CLEAR POLYCARBONATE
1/4" (6mm) CLEAR TEMPERED GLASS
BRASS LIGATURE-RESISTANT KNOB
(REFER TO PAGE VC 1.2.1
FOR OPTIONAL OPERATORS)
ROUND PLATE
VISION CONTROL
®
PANEL
SILICONE SEALANT
EXTERIOR
DETAIL
BRASS LIGATURE-RESISTANT KNOB
(REFER TO PAGE VC 1.2.1
FOR OPTIONAL OPERATORS)
ROUND PLATE
1/2" (12.7mm)1/4" CLEAR
POLYCARBONATE
1/4" (6mm) CLEAR TEMPERED GLASS
STRUCTURAL SILICONE JOINT
VISION CONTROL
®
PANEL
GEAR HOUSING
ALUMINUM SUPPORT
FOR SETTING BLOCK
(WELDED EXTENSION)
SETTING BLOCK
20
.6
mm
13
/1
6''
UNICEL'S CURTAIN WALL (CW) SYSTEM
- SEE SECTION CURTAIN WALL (CW) OF
UNICEL'S CORPORATE CATALOG
WIELDED PERIMETER
ALUMINUM ANGLE 2"X2"X1/4"
STRUCTURAL SILICONE JOINT
ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL
AAMA 501.8-TESTED FOR
2000 FT-LB HUMAN IMPACTS
AAMA 501.8-TESTED FOR
2000 FT-LB HUMAN IMPACTS
WOOD BLOCKING
AutoCAD SHX Text R
-
VC 3.1.1
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
C
B
A
12
.7
mm
1/2
''
15
.9
mm
5/8
''
58
.7
mm
2 5
/1
6''
12
.7
mm
1/2
''
42
.9
mm
1 1
1/1
6''
58
.7
mm
2 5
/1
6''
50.8mm
2''
82.6mm
3 1/4''
44.5mm
1 3/4''
12
.7
mm
1/2
''
A
C
9.5mm
3/8''
27mm
1 1/16''
B
82
.6
mm
3 1
/4
''
63
.5
mm
2 1
/2
''
2020
VISION CONTROL
®
DOOR CONFIGURATION
CRANK HANDLE OPERABLE ON ONE OR BOTH SIDE(S)
VISION CONTROL
®
FURNISHED FACTORY-GLAZED IN UNICEL'S ALUMINUM TRIMS
VISION CONTROL
®
PANEL
OVAL PLATE
SETTING BLOCK
BY UNICEL
VA
RIE
S
FOLDABLE ZINC
CRANK HANDLE
DOOR BY OTHERS
COEX GLAZING
SNAP-ON TRIM
SETTING BLOCK
BY UNICEL
GEAR HOUSING
VISION CONTROL
®
PANEL
FOLDABLE ZINC
CRANK HANDLE
(OPTIONAL)
VA
RIE
S
GEAR HOUSING
DOOR
BY OTHERS
COEX GLAZING
SNAP-ON TRIM
FOLDABLE ZINC
CRANK HANDLE
(OPTIONAL)
FOLDABLE ZINC
CRANK HANDLE
OVAL PLATE
(N
ON
-S
TA
ND
AR
D L
OC
AT
IO
N
FO
R O
PE
RA
TO
RS
A
VA
IL
AB
LE
)
FOLDABLE ZINC
CRANK HANDLE
(WHITE OR GRAY)
OVAL
PLATE
STANDARD FINISHES*
DURACRON WHITE K-1285
DURACRON GRAY K-20794
CLEAR ANODIZED (CLASS II)
LOUVERS DOOR TRIMS
* OTHER FINISHES AVAILABLE UPON REQUEST.
SETTING BLOCK
BY OTHERS
OPTIONAL OPERATORS:
31/32'' (24.6mm) Ø
BRASS LIGATURE-RESISTANT KNOB
(PAINTED WHITE OR GRAY)
3/4" (19.1mm) Ø
ALUMINUM KNOB
- WHITE K-1285
- GRAY K-20794
- CUSTOM COLORS
-
VC 3.1.2
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
C
B
A
12.7m
m
1/2''
15.9m
m
5/8''
58.7m
m
2 5/16''
12.7m
m
1/2''
187.3m
m
7 3/8''
A76.2m
m
3''
9.5mm
3/8''
9.5mm
3/8''
27mm
1 1/16''
82.6m
m
3 1/4''
50.8m
m
2''
B
9.5m
m
3/8''
9.5m
m
3/8''
42.9m
m
1 11/16''
58.7m
m
2 5/16''
50.8mm
2''
82.6mm
3 1/4''
44.5mm
1 3/4''
187.3m
m
7 3/8''
12.7m
m
1/2''
C
9.5mm
3/8''
2020
9.5mm
3/8''
VISION CONTROL
®
DOOR CONFIGURATION
STANDARD FINISHES*
DURACRON WHITE K-1285
DURACRON GRAY K-20794
CLEAR ANODIZED (CLASS II)
LOUVERS DOOR TRIMS
* OTHER FINISHES AVAILABLE UPON REQUEST.
THUMBWHEEL OPERABLE ON BOTH SIDES
VISION CONTROL
®
FURNISHED FACTORY-GLAZED IN UNICEL'S ALUMINUM TRIMS
THUMBWHEEL
OPERATOR
DOOR
BY OTHERS
DOOR BY OTHERS
COEX GLAZING
SNAP-ON TRIM
SETTING BLOCK
BY UNICEL
VISION CONTROL
®
PANEL
CUT-OUT
COEX GLAZING
SNAP-ON TRIM
SETTING BLOCK
BY UNICEL
VISION CONTROL
®
PANEL
SETTING BLOCK
BY OTHERS
FULL THUMBWHEEL
OPERATOR
- WHITE ALUMINUM
- GRAY ALUMINUM
- BLACK POLYMER
FULL THUMBWHEEL
OPERATOR
- WHITE ALUMINUM
- GRAY ALUMINUM
- BLACK POLYMER
-
VC 3.1.3
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
A
B
C
82
.6
mm
3 1
/4
''
50
.8
mm
2''
B
42
.9
mm
1 1
1/1
6''
58
.7
mm
2 5
/1
6''
50.8mm
2''
82.6mm
3 1/4''
44.5mm
1 3/4''
18
7.3
mm
12
.7
mm
1/2
''
A
9.5mm
3/8''
7 3
/8
"
A
12
.7
mm
1/2
''
58
.7
mm
2 5
/1
6''
12
.7
mm
1/2
''
18
7.3
mm
C
7 3
/8
"
76
.2
mm
3''
9.5mm
3/8''
9.5mm
3/8''
27mm
1 1/16''
9.5
mm
3/8
''
9.5mm
3/8''
2020
VISION CONTROL
®
DOOR CONFIGURATION
STANDARD FINISHES*
DURACRON WHITE K-1285
DURACRON GRAY K-20794
CLEAR ANODIZED (CLASS II)
LOUVERS DOOR TRIMS
* OTHER FINISHES AVAILABLE UPON REQUEST.
FAN-SHAPED THUMBWHEEL OPERABLE ON ONE SIDE
VISION CONTROL
®
FURNISHED FACTORY-GLAZED IN UNICEL'S ALUMINUM TRIMS
DOOR
BY OTHERS
DOOR BY OTHERS
COEX GLAZING
SNAP-ON TRIM
SETTING BLOCK
BY UNICEL
VISION CONTROL
®
PANEL
CLOSED OPEN
VISION CONTROL
®
PANEL
SETTING BLOCK
BY UNICEL
FAN-SHAPED
THUMBWHEEL OPERATOR
CUT-OUT
COEX GLAZING
SNAP-ON TRIM
SETTING BLOCK
BY OTHERS
± 115°
NOTE:
ROTATION LIMITED TO
APPROX. 115° INSTEAD OF 180°
LOUVERS COME DOWN
FROM OPERABLE SIDE
FAN-SHAPED
THUMBWHEEL
OPERATOR
- WHITE ALUMINUM
- GRAY ALUMINUM
- BLACK POLYMER
FAN-SHAPED
THUMBWHEEL
OPERATOR
- WHITE ALUMINUM
- GRAY ALUMINUM
- BLACK POLYMER
-
VC 3.2
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
A
50.8mm
2''
A
B
1.6mm
1/16''
12.7mm
1/2''
1.6mm
1/16''
12.7mm
1/2''
B
1.6mm
1/16''
12.7mm
1/2''
1.6mm
1/16''
12.7mm
1/2''
D
C D
50.8mm
2''
187.3m
m
7 3/8''
C
9.5mm
3/8''
50.8mm
2''
1.6mm
1/16''
3.2mm
1/8''
1.6mm
1/16''
3.2mm
1/8''
161.9m
m
6 3/8''
12.7m
m
1/2''
12.7m
m
1/2''
12.7m
m
1/2''
161.9m
m
6 3/8''
12.7m
m
1/2''
2020
50.8mm
2''
1.6mm
1/16''
12.7mm
1/2''
1.6mm
1/16''
12.7mm
1/2''
9.5mm
3/8''
9.5mm
3/8''
44.5mm
1 3/4''
44.5mm
1 3/4''
44.5mm
1 3/4''
44.5mm
1 3/4''
28.6m
m
1 1/8''
28.6m
m
1 1/8''
28.5m
m
1 1/8''
28.5m
m
1 1/8''
187.3m
m
7 3/8''
GEAR HOUSING
VISION CONTROL
®
PANEL
FOLDABLE ZINC
CRANK HANDLE
FOLDABLE ZINC
CRANK HANDLE
(OPTIONAL)
DETAIL
SUGGESTED CUSTOM DOOR TRIMS BY OTHERS
VISION CONTROL
®
PANEL
DETAIL
DETAIL
FULL THUMBWHEEL
OPERABLE ON
BOTH SIDES
VISION CONTROL
®
PANEL
DETAIL
FAN-SHAPED
THUMBWHEEL
OPERABLE
ON ONE SIDE ONLY
VISION CONTROL
®
PANEL
CU
T-O
UT
CU
T-O
UT
CUT-OUT
BY OTHERS
CUT-OUT
BY OTHERS
GLAZING TAPE
BY OTHERS
GLAZING TAPE
BY OTHERS
GLAZING TAPE
BY OTHERS
FOLDABLE ZINC
CRANK HANDLE
FOLDABLE ZINC
CRANK HANDLE
(OPTIONAL)
GEAR HOUSING
VISION CONTROL
®
DOOR CONFIGURATION
± 115°
NOTE:
ROTATION LIMITED TO
APPROX. 115° INSTEAD OF 180°
LOUVERS COME DOWN
FROM OPERABLE SIDE
GLAZING TAPE
BY OTHERS
DOOR BY OTHERS
WOOD TRIM
BY OTHERS
SETTING BLOCK
BY OTHERS
DOOR BY OTHERS
STEEL TRIM
BY OTHERS
SETTING BLOCK
BY OTHERS
DOOR BY OTHERS
WOOD TRIM
BY OTHERS
SETTING BLOCK
BY OTHERS
DOOR BY OTHERS
STEEL TRIM
BY OTHERS
SETTING BLOCK
BY OTHERS
OPTIONAL OPERATORS:OPTIONAL OPERATORS:
31/32'' (24.6mm) Ø
BRASS LIGATURE-RESISTANT KNOB
(PAINTED WHITE OR GRAY)
3/4" (19.1mm) Ø
ALUMINUM KNOB
31/32'' (24.6mm) Ø
BRASS LIGATURE-RESISTANT KNOB
(PAINTED WHITE OR GRAY)
3/4" (19.1mm) Ø
ALUMINUM KNOB
-
VC 4.1.1
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
2020
CARACTÉRISTIQUES DU MOTEUR:
5
6
4
1
3
2
7
1- WORM GEAR SHAFT
2- GEARING WHEEL
3- GEAR HOUSING 2 1/8" x 2 9/32" (54mm x 57.9mm)
4- PLASTIC COVER & SCREW #5-40 x 1/2" (12.7mm)
5- FLEXIBLE CABLE
6- SOMFY
®
MOTOR
7- VISION CONTROL
®
PANEL
MOTOR TYPE TO BE DETERMINED BY
UNICEL'S ENGINEERING DEPARTMENT
NOTE: REFER TO APPROVED SHOP DRAWINGS FOR MORE INFORMATION
SOMFY
®
MOTOR
VISION CONTROL
®
MOTORIZATION
- MODEL: SOMFY
®
- APPROX. DIM.: 29/32" x 1 7/32"
(23.1mm x 31.2mm)
- AMP: 1.2
- VOLTS: 12 DC
- RPM: 68
- RTS: 433.42 MHZ
-
VC 4.1.2
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
28.6mm
1 1/8"
2020
2
1
4
3
CLEARANCE
(TYPICAL)
VISION CONTROL
®
GROUPED MOTORIZATION
SOMFY
®
MOTOR
UNLIMITED NUMBER OF VISION CONTROL
®
PANELS (ONE MOTOR PER UNIT)
1- SOMFY
®
MOTOR
2- GEAR HOUSING 2 1/8" x 2 9/32"
(54mm x 57.9mm)
3- FLEXIBLE CABLE
4- VISION CONTROL
®
PANEL
VISION CONTROL
®
PANEL
WIRING DIAGRAM FOR 12 VOLT DC MOTOR
- MODEL: SOMFY
®
- APPROX. DIM.: 29/32" x 1 7/32"
(23.1mm x 31.2mm)
- AMP: 1.2
- VOLTS: 12 DC
- RPM: 68
- RTS: 433.42 MHZ
MOTOR SPECIFICATIONS:
12 VOLT
POWER SUPPLY
120 - 220 V/AC
MOTOR
-
VC 4.1.3
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
2020
B
B
50.8mm
2''
18
7.3
mm
127mm OR 152.4mm
5" OR 6"
25
.4
mm
1''
44
.5
mm
1 3
/4
''
44
.4
mm
1 3
/4
''
6.4
mm
1/4
''
25.4mm
1''
7 3
/8
"
57.9mm
2 9/32''
54
mm
2 1
/8
''
57.9mm
2 9/32''
A
10
1.6
mm
4''
A
28.6mm
1 1/8''
44.5mm
1 3/4''
44.4mm
1 3/4''
23.1mm
29/32''
31
.2
mm
1 7
/3
2''
50
.8
mm
2''
25
.4
mm
1''
5" O
R 6
"
SOMFY
®
MOTOR
VISION CONTROL
®
MOTORIZATION
INTERIOR
DETAIL
SOMFY
®
MOTOR
SETTING BLOCK
BY OTHERS
VISION CONTROL
®
PANEL
ALUMINUM FRAME &
GLASS STOPS
BY UNICEL
GEAR HOUSING
VA
RIE
S
INTERIOR
DETAIL
SOMFY
®
MOTOR
GEAR HOUSING
VISION CONTROL
®
PANEL
ALUMINUM FRAME &
GLASS STOPS
BY UNICEL
12
7m
m O
R 1
52
.4
mm
- MODEL: SOMFY
®
- APPROX. DIM.: 29/32" x 1 7/32"
(23.1mm x 31.2mm)
- AMP: 1.2
- VOLTS: 12 DC
- RPM: 68
- RTS: 433.42 MHZ
MOTOR SPECIFICATIONS:
FLEXIBLE CABLE
-
VC 4.2.1
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
2020
4
3
9
2
1
5
8
10
6
7
10
1- WORM GEAR SHAFT
2- GEARING WHEEL
3- GEAR HOUSING 2 1/8" x 2 9/32" (54mm x 57.9mm)
4- PLASTIC COVER & SCREW #5-40 x 1/2" (12.7mm)
5- FLEXIBLE CABLE
6- CORNER DRIVE
7- BALDOR MOTOR
8- RIGID SHAFT 5/8" Ø (15.9mm)
9- VISION CONTROL
®
PANEL
10- SET SCREW #10-24 x 3/16" (4.8mm)
MOTOR TYPE TO BE DETERMINED BY
UNICEL'S ENGINEERING DEPARTMENT
NOTE: REFER TO APPROVED SHOP DRAWINGS FOR MORE INFORMATION
BALDOR MOTOR
VISION CONTROL
®
MOTORIZATION
- MODEL: BALDOR
- APPROX. DIM.: 3 3/4" x 8 1/8"
(95.3mm x 206.4mm)
- AMP: 1
- VOLTS: 120 AC
- RPM: 163
- HZ: 60
- PHASE: 1
- TORQUE 28.5 IN-LB
MOTOR SPECIFICATIONS:
-
5
4
1
7
2
3
3
6
VC 4.2.2
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
12.7mm
1/2"
8
FIL
#5NC
NO
C#5
#1
#0
#0NC
NO
C
CAM
2020
CLEARANCE
(TYPICAL)
VISION CONTROL
®
GROUPED MOTORIZATION
(WITH LIMIT SWITCH)
BALDOR MOTOR
MAXIMUM OF 12 VISION CONTROL
®
PANELS PER MOTOR (MAY VARY DEPENDING ON SIZES)
1- BALDOR MOTOR
2- CORNER DRIVE
3- GEAR HOUSING 2 1/8" x 2 9/32"
(54mm x 57.9mm)
4- FLEXIBLE CABLE
5- RIGID SHAFT 5/8" Ø (15.9mm)
6- VISION CONTROL
®
PANEL
7- JUNCTION BOX
8- LIMIT SWITCH
VISION CONTROL
®
PANEL
WIRING DIAGRAM FOR 120 VOLT AC MOTOR WITH LIMIT SWITCH
ELECTRICAL DIAGRAM
NOTES:
1- SWITCH SPDT SHOWN FOR ILLUSTRATION ONLY
2- LIMIT SWITCH SHOWN IN CLOSED POSITION
3- POWER TO THE #5 WIRE OPERATES UNIT INTO CLOSED POSITION
4- POWER TO THE #0 WIRE OPERATES UNIT INTO CLOSED POSITION
- MODEL: BALDOR
- APPROX. DIM.: 3 3/4" x 8 1/8"
(95.3mm x 206.4mm)
- AMP: 1
- VOLTS: 120 AC
- RPM: 163
- HZ: 60
- PHASE: 1
- TORQUE 28.5 IN-LB
MOTOR SPECIFICATIONS:
LIMIT SWITCH
JUNCTION BOX
ELECTRIC BOX FOR SWITCH
(MUST BE INSTALLED
IN A LOCATION PERMITTING
VISUAL CONTROL)
120 - 220 V-AC
CAPACITOR
MOTOR
LIMIT
SWITCH
AC LINE
120 VOLTS
MOTOR
SPDT
SWITCH
-
5
VC 4.2.3
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
3
6
2
4
7
3
#1
#5
#0
1
2020
12.7mm
1/2"
VISION CONTROL
®
GROUPED MOTORIZATION
(WITHOUT LIMIT SWITCH)
BALDOR MOTOR
MAXIMUM OF 12 VISION CONTROL
®
PANELS PER MOTOR (MAY VARY DEPENDING ON SIZES)
1- BALDOR MOTOR
2- CORNER DRIVE
3- GEAR HOUSING 2 1/8" x 2 9/32"
(54mm x 57.9mm)
4- FLEXIBLE CABLE
5- RIGID SHAFT 5/8" Ø (15.9mm)
6- VISION CONTROL
®
PANEL
7- JUNCTION BOX
VISION CONTROL
®
PANEL
WIRING DIAGRAM FOR 120 VOLT AC MOTOR WITHOUT LIMIT SWITCH
- MODEL: BALDOR
- APPROX. DIM.: 3 3/4" x 8 1/8"
(95.3mm x 206.4mm)
- AMP: 1
- VOLTS: 120 AC
- RPM: 163
- HZ: 60
- PHASE: 1
- TORQUE 28.5 IN-LB
MOTOR SPECIFICATIONS:
JUNCTION BOX
WIRE
ELECTRIC BOX FOR SWITCH
(MUST BE INSTALLED
IN A LOCATION PERMITTING
VISUAL CONTROL)
120 - 220 V-AC
MOTOR
ELECTRICAL DIAGRAM
MOTOR
CAPACITOR
GREEN - YELLOW
NEUTRAL
120 VOLTS AC
SWITCH
CLEARANCE
(TYPICAL)
-
MIN
IM
UM
8
" (2
03
.2
m
m)
19mm
3/4''
28
.6
mm
1 1
/8
''
19.1mm
3/4''
28
.6
mm
1 1
/8
''
63
.5
mm
2 1
/2
''
18
7.3
mm
63
.5
mm
2 1
/2
''
8.9
mm
11
/3
2''
88.9mm
3 1/2''
21.1mm
27/32''
B
50.8mm
2''
18
7.3
m
m
12
.7
mm
1/2
''
50.8mm
2''
63
.5
mm
2 1
/2
''
9.5
mm
3/8
''
VC 4.2.4
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
A
7 3
/8
"
7 3
/8
"
A
B
2020
54
mm
2 1
/8
''
57.9mm
2 9/32''
54
mm
2 1
/8
''
57.9mm
2 9/32''
12
.7
mm
1/2
''
50
.8
mm
2''
VA
RIE
S
THERMALLY BROKEN
ALUMINUM FRAME
DETAIL
INTERIOR WALL
DETAIL
EXTERIOR WALL
VISION CONTROL
®
PANEL
BALDOR MOTOR
CORNER DRIVE
ALUMINUM
TRACK
LAY-IN CEILING
FLEXIBLE CABLE
GEAR HOUSING
LIMIT SWITCH
BALDOR MOTOR
CORNER DRIVE
FLEXIBLE CABLE
GEAR HOUSING
VISION CONTROL
®
PANEL
- MODEL: BALDOR
- APPROX. DIM.: 3 3/4" x 8 1/8"
(95.3mm x 206.4mm)
- AMP: 1
- VOLTS: 120 AC
- RPM: 163
- HZ: 60
- PHASE: 1
- TORQUE 28.5 IN-LB
MOTOR SPECIFICATIONS:
VISION CONTROL
®
MOTORIZATION
BALDOR MOTOR
(SUGGESTED DETAIL)
WITHOUT LIMIT SWITCH WITH LIMIT SWITCH
-
5
VC 4.3.1
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
2020
3
2
4
1
9
10
6
7
8
10
MOTOR TYPE TO BE DETERMINED BY
UNICEL'S ENGINEERING DEPARTMENT
NOTE: REFER TO APPROVED SHOP DRAWINGS FOR MORE INFORMATION
PITTMAN MOTOR
VISION CONTROL
®
MOTORIZATION
- MODEL: PITTMAN
- APPROX. DIM.: 2" x 3 5/8"
(50.8mm x 92.1mm)
- AMP: 0.6
- VOLTS: 24 DC
- RPM: 160
MOTOR SPECIFICATIONS:
1- WORM GEAR SHAFT
2- GEARING WHEEL
3- GEAR HOUSING 2 1/8" x 2 9/32" (54mm x 57.9mm)
4- PLASTIC COVER & SCREW #5-40 x 1/2" (12.7mm)
5- FLEXIBLE CABLE
6- CORNER DRIVE
7- PITTMAN MOTOR
8- RIGID SHAFT 5/8" Ø (15.9mm)
9- VISION CONTROL
®
PANEL
10- SET SCREW #10-24 x 3/16" (4.8mm)
-
SEE VC 4.3.4
VC 4.3.2
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
1 2
3
4
6
7 8
A
5
#5
#0
#1
24 VDC
2020
VISION CONTROL
®
MOTORIZATION
(WITH LIMIT SWITCH)
1- PITTMAN MOTOR
2- CORNER DRIVE
3- GEAR HOUSING 2 1/8" x 2 9/32"
(54mm x 57.9mm)
4- FLEXIBLE CABLE
5- RIGID SHAFT 5/8" Ø (15.9mm)
6- VISION CONTROL
®
PANEL
7- JUNCTION BOX
8- LIMIT SWITCH
VISION CONTROL
®
PANEL
WIRING DIAGRAM FOR 24 VDC MOTOR WITH LIMIT SWITCH
LIMIT SWITCH
JUNCTION BOX
WIRE
24 VDC POWER SUPPLY
120 - 220 V-AC
MOTOR
WIRE
STANDARD ELECTRIC BOX
FOR DPDT SWITCH
LIMIT
SWITCH
LIMIT
SWITCH
RED
BLACK
RED
BLACK
MOTOR
ELECTRICAL DIAGRAM
DPDT MAINTAIN OR
MOMENTARY SWITCH
PITTMAN MOTOR
MAXIMUM OF 4 VISION CONTROL
®
PANELS PER MOTOR (MAY VARY DEPENDING ON SIZES)
- MODEL: PITTMAN
- APPROX. DIM.: 2" x 3 5/8"
(50.8mm x 92.1mm)
- AMP: 0.6
- VOLTS: 24 DC
- RPM: 160
MOTOR SPECIFICATIONS:
AutoCAD SHX Text+
AutoCAD SHX Text-
-
VC 4.3.3
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
12
3
4
7
6
B
5
FIL
FIL
24 VDC
2020
VISION CONTROL
®
MOTORIZATION
(WITHOUT LIMIT SWITCH)
SEE VC 4.3.4
1- PITTMAN MOTOR
2- CORNER DRIVE
3- GEAR HOUSING 2 1/8" x 2 9/32"
(54mm x 57.9mm)
4- FLEXIBLE CABLE
5- RIGID SHAFT 5/8" Ø (15.9mm)
6- VISION CONTROL
®
PANEL
7- JUNCTION BOX
VISION CONTROL
®
PANEL
WIRING DIAGRAM FOR 24 VDC MOTOR WITHOUT LIMIT SWITCH
JUNCTION BOX
24 VDC POWER SUPPLY
LOCATE THIS SUPPLY NEAR
YOUR ELECTRICAL PANEL
120 - 220 V-AC
MOTOR
STANDARD ELECTRIC BOX
FOR DPDT SWITCH
ELECTRICAL DIAGRAM
MOTOR
RED
BLACK
DPDT
MOMENTARY
SWITCH
RED
BLACK
PITTMAN MOTOR
MAXIMUM OF 4 VISION CONTROL
®
PANELS PER MOTOR (MAY VARY DEPENDING ON SIZES)
- MODEL: PITTMAN
- APPROX. DIM.: 2" x 3 5/8"
(50.8mm x 92.1mm)
- AMP: 0.6
- VOLTS: 24 DC
- RPM: 160
MOTOR SPECIFICATIONS:
AutoCAD SHX Text+
AutoCAD SHX Text-
-
A
50
.8
mm
2''
28
.6
mm
1 1
/8
''
50
.8
mm
2''
50
.8
mm
2''
28
.6
mm
1 1
/8
''
18
7.3
mm
7 3
/8
''
12
.7
mm
1/2
''
50.8mm
2''
1.6mm
1/16''
1.6mm
1/16''
19.1mm
3/4''
19.1mm
3/4''
VC 4.3.4
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
B
50
.8
mm
2''
28
.6
mm
1 1
/8
''
50
.8
mm
2''
50
.8
mm
2''
28
.6
mm
1 1
/8
''
18
8.1
mm
7 1
3/3
2''
12
.7
mm
1/2
''
2020
19.1mm
3/4''
19.1mm
3/4''
50.8mm
2''
1.6mm
1/16''
1.6mm
1/16''
54
mm
2 1
/8
''
57.9mm
2 9/32''
54
mm
2 1
/8
''
57.9mm
2 9/32''
VA
RIE
S
INTERIOR WALL
DETAIL
VISION CONTROL
®
MOTORIZATION
PITTMAN MOTOR
(SUGGESTED DETAIL)
PITTMAN MOTOR
CORNER DRIVE
ALUMINUM
SUPPORT
ALUMINUM TRACK
LIMIT SWITCH
BOX
LAY-IN CEILING
BY OTHERS
FLEXIBLE CABLE
GEAR HOUSING
VA
RIE
S
INTERIOR WALL
DETAIL
PITTMAN MOTOR
CORNER DRIVE
ALUMINUM
SUPPORT
ALUMINUM TRACK
LAY-IN CEILING
BY OTHERS
FLEXIBLE CABLE
- MODEL: PITTMAN
- APPROX. DIM.: 2" x 3 5/8"
(50.8mm x 92.1mm)
- AMP: 0.6
- VOLTS: 24 DC
- RPM: 160
ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL
ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL
GEAR HOUSING
MOTOR SPECIFICATIONS:
VISION CONTROL
®
PANEL
VISION CONTROL
®
PANEL
WITH LIMIT SWITCH WITHOUT LIMIT SWITCH
-
5
0
.
8
m
m
2
'
'
VC 5.1
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
2020
6
.
4
m
m
1
/
4
'
'
A
A
A
A
SKYLIGHT
VISION CONTROL
®
MOTORIZATION APPLICATION
VISION CONTROL
®
PANEL
FLEXIBLE CABLE
CORNER DRIVE
MOTOR
FLASHING
ALUMINUM PLATE
MEMBRANE
GEAR HOUSING
UNICEL'S SKYLIGHT FRAMING SYSTEM
- SEE SECTION SKYLIGHT (SK) OF
UNICEL'S CORPORATE CATALOG
DETAIL
EXTERIOR
-
VC 5.2
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
2020
BOÎTE
D'ENGRENAGE
M
I
N
.
2
0
3
.
2
m
m
8
'
'
M
I
N
.
2
0
3
.
2
m
m
8
'
'
B
B
B
SOLARIUM
VISION CONTROL
®
MOTORIZATION APPLICATION
VISION CONTROL
®
PANEL
CRANK HANDLE
UNICEL'S SKYLIGHT (SK) SYSTEM
- SEE SECTION SKYLIGHT (SK) OF
UNICEL'S CORPORATE CATALOG
GEAR HOUSING
VISION CONTROL
®
PANEL
BALDOR MOTOR
PITTMAN MOTOR
DETAIL
EXTERIOR
DETAIL
EXTERIOR
FLEXIBLE CABLE
-
VC 5.3
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
2020
4
8
6
3
9
6
8
7
4
5
2
5
2
1
VISION CONTROL
®
MOTORIZATION APPLICATION
SLOPED GLAZING
1- MOTOR
2- CORNER DRIVE
3- GEAR HOUSING 2 1/8" x 2 9/32" (54mm x 57.9mm)
4- FLEXIBLE CABLE
5- RIGID SHAFT 5/8" Ø (15.9mm)
6- VISION CONTROL
®
PANEL
7- ALUMINUM SUPPORT
8- ALUMINUM STRUCTURE
9- SETTING BLOCK
-
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 6.1
3
0
4
.
8
m
m
1
'-
0
''
30
4.8
mm
1'-0
''
2020
Storage Instructions
A. In Crates
Crates must be kept upright, covered, ventilated and in a dry and safe location.
B. Loose Lots
Sealed units must be upright, on blocks and in a safe and dry location. Sealed units should not be stored in
a stack, or in direct sunlight as heat build-up may cause breakage. Sealed units should have a base to
provide support to all component lites of the unit so that individual lites will not slide out of alignment or out
of square causing seal failure or breakage.
Handling Instructions
A. Extreme care must be taken when a unit is being moved. Edges and corners should be protected in order to
prevent glass from fracturing. The use of a corner protector is suggested.
FLOOR
WA
LL
CORRECT
METHOD
FLOOR
WA
LL
INCORRECT
METHOD
B. When moving Vision Control
® sealed glass panels, always do so as indicated below, flat or the gearhousing downwards.
VISION CONTROL
®
STORAGE & HANDLING
SEALED UNIT
CORNER PROTECTOR
WOOD BLOCKING
PLYWOOD
1/2" (12.7mm)
GEAR HOUSING
GEAR HOUSING
V
A
R
I
E
S
1
st
method : Flat 2
nd
method: Gear housing down
-
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 6.2
2020
Frame/Sash
1. All framing members must be specifically designed to accept the glass specified and must have adequate structural
strength to support the weight of the glass without deformation.
2. Frame and/or sash must be level, plumb, square and in plane and also be free of any glazing obstruction.
3. Joints must be adequately buttered with sealant to prevent water and air infiltration and all sill members must have
weep holes to the outside.
Clearance and edge bite
1. Adequate edge and face clearances must be provided to allow the glass to float freely in the opening, without undue
restriction by the framing members. The recommended clearance on both vertical edges of the units is a minimum
of 3/8" (9.5mm) for thumbwheel-operated units, 1/2" (12.7mm) for units operated by crank handles, knobs or
Pittman and Baldor motors and 1 1/8" for Somfy motors.
2. Adequate bite is mandatory to maintain a watertight, weather-proof seal as well as retain the glass in the opening
under conditions of wind loading and deformation of the framing members.
Setting blocks
1. Neoprene setting blocks should be used on the bottom edge of each sealed unit. Place setting blocks at the end
points, under the metallic plates.
Sealing materials
1. For channel glazing, use only a non-hardening, non-corrosive, gun-applied sealant specifically recommended by the
sealant manufacturer for the type of glass specified
2. In no case shall glazing be performed with any oleo-resinous or oil-base compounds, nor shall any glazing sealant
be diluted or thinned with any solvent.
3. Never fill the space between the bottom edge of the glass and the sill. This will interfere with the weepage system.
4. All sealants must be applied to provide an absolute watertight seal; on insulating glass units, sealant must contact
the glass a minimum of 1/8” above the metal edge protection.
5. Sash with neoprene or structural neoprene gaskets must have a supplementary wet seal applied between the
gasket and the glass, at the bottom edge (sill) of the glass and 6” (152.4mm) up on each jamb. Sill section of all
structural neoprene gaskets must have weep holes to the exterior.
6. Special care must be taken when glazing laminated glass, polycarbonates and glass-clad polycarbonates, as they
may react unfavorably with certain sealant components. Sealants made of 100% solid components, containing no
solvents, must be used. Verify with your sealant manufacturer.
7. All surfaces to be sealed must be completely clean and dry. Verify with sealant manufacturer's recommendations for
proper cleaning procedures.
VISION CONTROL
®
INSTALLATION
GLAZING INSTRUCTIONS
-
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 6.3
13
2020
5A
15
6
7A
8
15
9
3
2
4
1
7A
8
6
15
5A
15
7B
5B
12
10
11
5C
14
15
5C
5B
7B
15
14
6
6
CRANK HANDLE OR KNOB OPERATORS
VISION CONTROL
®
INSTALLATION
HOLE (SEE STEP D)
OPTION: DOUBLE
ALUMINUM KNOB
OPTION: DOUBLE ZINC
CRANK HANDLE
A. Install stainless steel worm gear shaft 1 into the cavity provided for it in the gear housing 3 . To insert the worm gear shaft in position, center it in the
gear housing and press firmly. Insert the white gearing wheel 2 on the brass shaft.
B. Make sure that the gear housing 3 is free of dirt. Screw the plastic cover 4 in place. Do not use excessive torque on screws in securing the plastic
cover.
C. (Skip this step if the operator is an ligature-resistant knob 5C ). Test the functionality of the units by temporarily installing the operator 5A or 5B and
tightening the set screw 15 . The mechanism is self-reversing and should be tested as follows: Turn the operator in one direction (e.g. clockwise).
When the louvers reach the closed position, continue turning 4-8 times in the same direction (e.g. clockwise) without fear of breaking the mechanism
until the louvers eventually re-open. Complete two full louver cycles by turning the operator in the same direction (e.g. clockwise). Repeat these steps
in the opposite direction (e.g. counter-clockwise) for two more full louver cycles.
D. Drill the following hole (behind the aluminum block 13 ) in glass stop at the appropriate position (for worm gear shaft 1 according to Unicel's approved
shop drawings): for the zinc crank handle 5A and the aluminum knob 5B , drill a 5/8" (15.9mm) diameter hole; for the ABS ligature-resistant knob 5C ,
drill a 3/8" (9.5mm) diameter hole.
E. Install setting blocks 12 under the metal plates glued to the unit. Make sure they are sufficiently rigid to secure glass panel into its permanent position.
F. Install the Vision Control
®
panel 9 in the opening which must be level, plumb, square and in plane. Make sure the shaft 1 is centered in the hole
drilled in step D.
G. If necessary, install aluminum supporting block 13 by securing with screws.
H. According to operator:
1. Zinc crank handle: Screw the oval plate 7A , the crank handle 5A and extension shaft 8 into the the frame with screws 6 .
Tighten the set screw 15 of the crank handle 5A if loose.
2. Aluminum knob: Screw the oval plate 7A , the knob 5B and extension shaft 8 into the the frame with screws 6 .
Tighten the set screw 15 of the knob 5B if loose.
3. Brass ligature-resistant knob: Assemble the extension shaft 8 with the round plate 7B and the brass adaptor 14 and tighten the first set screw.
Fix the assembly and the base of the knob 5C into the frame with screws 6 . Push the knob 5C into its base and tighten the second set screw 15 .
OPTION: REMOVABLE ZINC CRANK HANDLE
OPTION: DOUBLE BRASS
LIGATURE-RESISTANT
KNOB
1- WORM GEAR SHAFT
2- GEARING WHEEL
3- GEAR HOUSING 2 1/8" x 2 9/32" (54mm x 57.9mm)
4- PLASTIC COVER & SCREW #5-40 x 1/2" (12.7mm)
5A- ZINC CRANK HANDLE
5B- ALUMINUM KNOB
5C- BRASS LIGATURE-RESISTANT KNOB
6- SCREW #6 x 1/2" (12.7mm)
7A- OVAL PLATE
7B- ROUND PLATE
8- EXTENSION SHAFT
9- VISION CONTROL
®
PANEL
10- FRAME BY OTHERS
11- HEXAGONAL SOCKET
12- SETTING BLOCK
13- ALUMINUM BLOCK
14- BRASS ADAPTOR
15- SET SCREW
15
15
-
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 6.4
2020
VISION CONTROL
®
INSTALLATION
FULL THUMBWHEEL OPERATOR
Install setting blocks under the metal plates glued to each unit. Make sure they are sufficiently rigid to secure the glass panels into their
permanent position. The units must be level, plumb, square and in plane. Install the glass stops, which should have been notched at
predetermined locations according to approved shop drawings, to accomodate thumbwheel operator.
ADDITIONAL INSTRUCTIONS
STEP 1 STEP 2
METAL PLATE
SETTING BLOCK
METAL PLATE
SETTING BLOCK
CIRCLIP
IMPORTANT NOTE:
Various thumbwheel diameters may occur throughout
this order. Please refer to approved shop drawings to
identify the proper thumbwheel diameter size to install.
This operation must be performed before installing
the sealed units in their respective openings.
Test the functionality of the units by turning the
thumbwheel in one direction (e.g. clockwise). When the
louvers reach the closed position, continue turning in
the same direction (e.g. clockwise) without fear of
breaking the mechanism until the louvers eventually
re-open. Complete two full louver cycles by turning the
operator, always in the same direction (e.g. clockwise).
Repeat these steps in the opposite direction (e.g.
counter-clockwise) for two more full louver cycles.
-
ARCHITECTURAL
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil • Québec • J4G 2J4 • Canada
R
T: 800.668.1580 | 450.670.6844 • F: 866.496.2628 | 450.670.7144
E: [email protected] • www.unicelarchitectural.com
VC 6.5.1
2020
Install setting block under the metal plates glued to each unit. Make sure they are sufficiently rigid to secure the glass panels into their
permanent position. The units must be level, plumb, square and in plane. Install the glass stops, which should have been notched at
predetermined locations according to approved shop drawings, to accomodate thumbwheel operator.
VISION CONTROL
®
INSTALLATION
IMPORTANT NOTE:
Various thumbwheel diameters may occur throughout this order.
Please refer to approved shop drawings to identify the proper thumbwheel diameter size to install.
This operation must be performed before installing the glass units in their respective openings.
Follow the instructions for either left side or right side, as required.
RIGHTLEFT
ADDITIONAL INSTRUCTIONS
FAN-SHAPED THUMBWHEEL OPERATORS
LEFT SIDE AND RIGHT SIDE
STICKERS SHOULD BE FACING OUT
LR
STEP 1
STEP 2
O
P
E
R
A
B
L
E
S
I
D
E
O
P
E
R
A
B
L
E
S
I
D
E
LEFT AND RIGHT SIDES WHEN
VIEWED FROM THE OPERABLE
SIDE OF THE ROOM
LOUVERS IN
OPEN POSITION
LOUVERS IN
OPEN POSITION
RIGHTLEFT
METAL PLATE
SETTING BLOCK
METAL PLATE
SETTING BLOCK