visual site inspection report - mountain valley pipeline...sep 18, 2018  · mv 11553+66 no no full...

3
1. 2. 3. 4. 5. Corrective Action Corrective Time Frame Date Repaired Visual Site Inspection Report AFE Date/Time Spread Report # Contractor Inspector Project Name E&S BMPs (List BMPs and note if installed and maintained as per the plan. If corrective action is needed, a picture is required.) E&S BMPs Compliance Level GPS Location Rain Accumulation Time (days) Are the approved (stamped) E&S Plan and PCSM Plan present on site? Are there activities occurring outside of the limits of disturbance shown on the plan drawings? (If yes, notify the MVP Environmental Permitting Coordinator and explain in comments.) Is Construction sequence outlined in the construction notes of the E&S plan set or PCSM plan set being followed? (If No, notify MVP Environmental Permitting Coordinator and explain in comments.) Permit # Inspection Type Station Begin State Inspection Area Station End Ground Temperature (ºF) Municipality Weather Rain Gauge (in) County Site Conditions Is an unauthorized discharge (such as sediment, gravel, oil, HDD fluid, etc.) occurring to waters, wetlands, or beyond defined limits of disturbance resulting from earth disturbance activity or ineffective BMP? If yes, take a photo and immediately contact MVP Environmental Permitting Coordinator. Have inactive disturbed areas (stockpiles, final grade) been stabilized per state requirements? Are slopes 3:1 and greater stabilized with appropriate BMPs as per E&S plans? Has a new slip/slide been observed? (If yes, complete Slide Report Form) MVP-34 REV 0 Page 1 of 3 cerjr 15166 9/18/2018 4:14:50 P -80.39 9/1 3.80 37.13 Yes 9/18/2018 8:25 AM 9/18/2018 4:13:55 P MV 11553+66 No No Full H-600 Pipeline Spread G No VA SWPP No 37.13364145, -80.39471332 VA 11596+94 3.00 Montgomery Yes N/A TBD Cloudy No MV Muddy 201809 P89 1414 Yes ENV-0 79.00 9/1 8053 124300137 9/18/2018 4:18:20 PM -04:00 N/A 9/1 H-600 Pipeline Spread G Precision Rob Robertson No Visual Site Inspection R Rob Robertson Erosion Control Blanket Housekeeping Stone Inlet Protection Sump Pit Silt Fence (Reinforced Filter Fabric Fence) Silt Fence (Filter Fabric Fence) Vegetative Stabilization (Temporary) Waterbar Waterbar Outlet Protection Communication Acceptable Acceptable Communication Acceptable Communication Communication Communication Communication Maintenance needed Maintenance needed Maintenance needed Adjust Ph levels Maintenance needed Maintenance needed 48 Hours 48 Hours 48 Hours 48 Hours 48 Hours 48 Hours

Upload: others

Post on 05-Mar-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Visual Site Inspection Report - Mountain Valley Pipeline...Sep 18, 2018  · MV 11553+66 No No Full H-600 Pipeline Spread G No VA SWPP No 37.13364145, -80.39471332 VA 11596+94 3.00

1.

2.

3.

4.

5.

Corrective ActionCorrective

Time Frame

Date

Repaired

Visual Site Inspection Report

AFE

Date/Time

Spread

Report # Contractor

Inspector

Project Name

E&S BMPs (List BMPs and note if installed and maintained as per the plan. If corrective action is needed, a picture

is required.)

E&S BMPsCompliance

Level

GPS Location Rain Accumulation Time (days)

Are the approved (stamped) E&S Plan and PCSM Plan present on site?

Are there activities occurring outside of the limits of disturbance shown on the plan drawings?

(If yes, notify the MVP Environmental Permitting Coordinator and explain in comments.)

Is Construction sequence outlined in the construction notes of the E&S plan set or PCSM plan set being

followed? (If No, notify MVP Environmental Permitting Coordinator and explain in comments.)

Permit # Inspection Type Station Begin

State Inspection Area Station End

Ground Temperature (ºF)

Municipality Weather Rain Gauge (in)

County

Site Conditions

Is an unauthorized discharge (such as sediment, gravel, oil, HDD fluid, etc.) occurring to waters, wetlands, or

beyond defined limits of disturbance resulting from earth disturbance activity or ineffective BMP? If yes, take

a photo and immediately contact MVP Environmental Permitting Coordinator.

Have inactive disturbed areas (stockpiles, final grade) been stabilized per state requirements?

Are slopes 3:1 and greater stabilized with appropriate BMPs as per E&S plans?

Has a new slip/slide been observed? (If yes, complete Slide Report Form)

MVP-34 REV 0 Page 1 of 3

cerjr

151669/18/2018 4:14:50 P

-80.399/1

3.80

37.13

Yes

9/18/2018 8:25 AM

9/18/2018 4:13:55 P

MV

11553+66

NoNo

Full

H-600 Pipeline Spread G

No

VA SWPP

No

37.13364145, -80.39471332

VA 11596+94

3.00

Montgomery

Yes

N/A

TBD

Cloudy

No

MV

Muddy

201809P89

1414

Yes

ENV-0

79.00

9/18053

124300137

9/18/2018 4:18:20 PM -04:00

N/A

9/1

H-600 Pipeline Spread G

Precision

Rob Robertson

No

Visual Site Inspection RRob Robertson

Erosion Control Blanket

Housekeeping

Stone Inlet Protection

Sump Pit

Silt Fence (Reinforced Filter Fabric Fence)

Silt Fence (Filter Fabric Fence)

Vegetative Stabilization (Temporary)

Waterbar

Waterbar Outlet Protection

Communication

Acceptable

Acceptable

Communication

Acceptable

Communication

Communication

Communication

Communication

Maintenance needed

Maintenance needed

Maintenance needed

Adjust Ph levels

Maintenance needed

Maintenance needed

48 Hours

48 Hours

48 Hours

48 Hours

48 Hours

48 Hours

Page 2: Visual Site Inspection Report - Mountain Valley Pipeline...Sep 18, 2018  · MV 11553+66 No No Full H-600 Pipeline Spread G No VA SWPP No 37.13364145, -80.39471332 VA 11596+94 3.00

6.

7.

Date

Repaired

Corrective

Time FrameCorrective Action

AFE Date/Time Report #

PCSM BMPs (List BMPs and note if installed and maintained as per the plan. If corrective action is needed, a

picture is required.)

PCSM BMPsCompliance

Level

Identify all remedial measures that have been taken since the previous inspection was conducted.

Comments (Reference above questions as appropriate.)

Note: It is a condition of National Pollutant Discharge Elimination System and Erosion and Sediment permits that a

maintenance program be conducted to provide for the operation and maintenance of all BMPs to be inspected on a

weekly basis and after each stormwater event. Please list in the space provided comments to note if repairs or

replacement are needed or have been made for BMPs as a result of the inspection. Failure to conduct the required

inspection may result in permit suspension or the imposition of civil penalties. If supplemental monitoring is required

as part of a permit condition this form may be used to meet those monitoring requirements.

MVP-34 REV 0 Page 2 of 3

9/18/2018 8:25 AM 8053124300137

Conducted the required VADEQ SWPPP inspection scheduled for today on Sinking Creek Mountain. The area has received 3.8” ofrainfall due to hurricane Florence over the past 3 days. Surface conditions are saturated. The contractor’s environmental crew wason site this morning to look at conditions and made minor repairs with hand tools before leaving. Transcon inspectors (3) were onsite looking for environmental compliance issues. Slope breaker, sump and end treatments need maintenance as expected. Nosediment migration beyond approved LOD was located. Recent installation of additional controls including stone in front of slopepipe inlets helped control run off and sediment migration. Several areas where stabilization failed on fill slopes and topsoil pileswere noted. A punch list of repairs needed was created and will be given to the contractor to add to the environmental crew’sfindings. It will be a couple of days before equipment can access ROW to assist with ECD repairs. No impact to resources wasidentified.

Page 3: Visual Site Inspection Report - Mountain Valley Pipeline...Sep 18, 2018  · MV 11553+66 No No Full H-600 Pipeline Spread G No VA SWPP No 37.13364145, -80.39471332 VA 11596+94 3.00

37.3738618148839, -80.7319978159673

37.13364145, -80.39471332

37.133130789769, -80.3945041728023

37.133130789769, -80.3945041728023

37.133130789769, -80.3945041728023

37.133130789769, -80.3945041728023Comment and correct coordinates on photo.Stone lined inlets helped control migration ofsediment.

Comment and correct coordinates on photo.Fill slope collapse near 11570+25

Comment and correct coordinates on photo.Topsoil storage piles not properly stabilized.

Comment and correct coordinates on photo.Slope pipe carrying water from spring near11569+00.

Comment and correct coordinates on photo.Maintenance needed for controls beyond LODat the S-PP21 crossing.

Comment and correct coordinates on photo.Outlet needed to convey water off ROW at11569+40.

9/18/2018 8:25 AM 8053124300137