vitocal / vitovent 300

20
VITOCAL Heat pumps VITOVENT 300 Domestic ventilation system

Upload: others

Post on 03-Feb-2022

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Vitocal / Vitovent 300

VITOCAL Heat pumps

VITOVENT 300Domestic ventilation system

Page 2: Vitocal / Vitovent 300
Page 3: Vitocal / Vitovent 300

Heating with nature’s resources .....

well into the future

Environmental awareness is risingas natural resources are exploitedto exhaustion, so the issue ofutilising renewable resourcescontinues to grow in importance.The increasing demand foreconomical and future-proofheating technology challengesevery responsible home owner and builder. Vitocal 300 heatpumps are one of many newsystems answering thesechallenges.

Elementary energies

Heat pumps utilise renewableenergy resources from the worldaround us. A modicum of electricalpower converts solar energy storedin the ground, or in groundwater,into convenient heating fuel.Viessmann heat pumps are soefficient, that they can even beutilised as sole heat provider.Air/water heat pumps can also be operated in parallel with anadditional heat generator to cover demand, for example, onparticularly cold days. In otherwords, you can achieve a trulydual-mode, energy-saving heatingsystem.

The right combination

Economical and environmentallyresponsible heating requires theright choice of equipment, too. The system design must provideoptimum matching of individualcomponents to work togetherharmoniously, to achieve thehighest level of efficiency withminimum effort. Additional solarcollectors and domestic ventilationsystems, with heat recovery, mayalso be used to supplement theheating operation.

The right decision

This brochure introduces you tothe most important, state of the art,heating technology componentswhich are also economical andenvironmentally-friendly.Viessmann’s system philosophyenables all components to worktogether, like the cogs in a watch,to achieve optimum energyutilisation, environmentalprotection and performance.

3

Index

VITOCAL 300heat pumps.............. Page 4 to 9VITOCAL 350heat pump................ Page 10/11VITOCAL 343Compact heatingtower......................... Page 12/13VITOVENT 300domestic ventilation Page 14/15SpecificationVitocal 300 / 350....... Page 16/17SpecificationVitocal 343 and Vitovent 300..............Page 18/19

Page 4: Vitocal / Vitovent 300
Page 5: Vitocal / Vitovent 300

5

Ground or groundwater as

heat source –

VITOCAL 300

Vitocal 300

Brine/water heat pump

Vitocal 300 heat pumps utiliserenewable energies from theground, groundwater and the air.Their efficiency enables them to beused as sole heat generator all theyear round.

Uniform design –

versatile performance

Every Vitocal heat pump followsthe Vitotec system designphilosophy, which is based on auniform building block principle.This makes installation,maintenance and service an easytask for your heating contractor.And, thanks to a Compliant scrollcompressor, Vitocal 300 not onlyoffers high operational safety andreliability, but also very quietoperation. The digital control unit,CD 60, offers the same degree ofconvenience, as it manages notonly the entire heating system, but also an optional solar heatingsystem. In summer, the controlfunction “Natural cooling” allowsthe low temperatures underground or in groundwater to beused to conveniently cool thebuilding (requires additionalcomponents).

Benefits at a glance:

● Suitable for all operating modes:– in mono operation provides

central and DHW heating– in dual-mode, it works in

combination with a second heatgenerator, e.g. in modernisationprojects.

● High operational safety andreliability, quiet operation throughhermetically sealed Compliantscroll compressor with double anti-vibration mounts.

● CFC-free, non-flammable andbiologically degradable refrigerantR 407 C.

● Particularly suitable for lowtemperature heating systems, e.g.underfloor heating systems.

● Weather-compensated digitalheating circuit control unit, CD 60,with start-up current limiter andintegral cooling and solar heatingfunctions – up to three loadingsources can be controlled. Menu-guided operation with plain textsupport and integral diagnosticsystem.

● Comprehensive model rangewith output ranging from– 4.8 to 32.6 kW as Vitocal 300

brine/water heat pump– 6.3 to 43.0 kW as Vitocal 300

water/water heat pump.

● High performance factors:– up to 4.61 as Vitocal 300

brine/water heat pump (brine: 0 °C, flow temperature: 35 °C),

– up to 5.90 as Vitocal 300water/water heat pump (groundwater: 10 °C, flowtemperature: 35 °C).

Heat from the ground

The Vitocal 300 brine/water heatpump utilises energy stored underground. Just as in groundwater,even temperatures prevailunderground all the year round.The pump withdraws energy fromthe ground, via a ground collector,set approximately 1.5 m deep intothe earth.

A space-saving alternative to theground collector is the groundprobe, which penetrates deeperinto the earth. At this level, thetemperature stays at a constant 10 °C all the year round. Thismakes Vitocal 300 independent ofprevailing outside temperatures,enabling the system to cover theentire heating operation – even oncold days.

To utilise groundwater energy,Vitocal 300 can be simplyconverted into a water/water heatpump. This mode achieves thehighest performance factor.

Page 6: Vitocal / Vitovent 300
Page 7: Vitocal / Vitovent 300

7

Two-stage heat pump up to 106.8 kW –

VITOCAL 300

Compliant scroll compressors

make Vitocal heat pumps not only

very safe and reliable, but also

extremely quietVitocal 300

Water/water heat pump

output up to 106.8 kW

The heart of the scroll compressor

The new two-stage version of theVitocal 300 heat pump achieves anoutput of up to 106.8 kW and issuitable for utilising groundwaterand ground energy sources.

These features enable this modelto be matched to any requirementand demand. The modular design,based on two compressor circuits,ensures particularly high efficiencyin the partial load range.

Benefits at a glance:

● Suitable for all operating modes:– in mono operation provides

central and DHW heating– in dual-mode, it works in

combination with a second heatgenerator, e.g. in modernisationprojects.

● Two-stage version enables partload operation.

● High operational safety andreliability, quiet operation throughhermetically sealed Compliantscroll compressor with double anti-vibration mounts.● CFC-free, non-flammable andbiologically degradable refrigerantR 407 C.

● Particularly suitable for lowtemperature heating systems, e.g.underfloor heating systems.

● Weather-compensated digitalheating circuit control unit, CD 60,with start-up current limiter andintegral cooling and solar heatingfunctions – up to three loadingsources can be controlled. Menu-guided operation with plain textsupport and integral diagnosticsystem.

● High performance factors:– up to 5.60 as Vitocal 300

water/water heat pump(groundwater: 10 °C, flowtemperature: 35 °C).

– up to 4.3 as Vitocal 300brine/water heat pump (brine: 0 °C, flow temperature: 35 °C).

All Vitocal 300 heat pumps aredesigned according to the Vitotecsystem design philosophy, which isbased on a uniform modularconcept. As a result, installation,maintenance and service aredramatically speeded up.

Whilst ensuring high operationalsafety and reliability, the Compliantscroll compressor makes Vitocal300 an extremely quiet operator.

Page 8: Vitocal / Vitovent 300
Page 9: Vitocal / Vitovent 300

Energy from the air –

VITOCAL 300

9

Vitocal 300

Air/water heat pump

Output: 5.4 to 14.6 kW

Weather-compensated, digital

CD 60 heating circuit control unit

with start-up current limiter and

integral cooling and solar heating

functions – up to three loading

groups may be controlled

The Vitocal 300 air/water heatpump utilises the outside airheated by the sun. The powerfulCompliant scroll compressor turnsthis energy into useful heat. TheCD 60 control unit operates withequal ease: apart from enabling allfunctions to be checked, it allowsconvenient communication withthe heat pump. Users are assistedby plain text displays whenselecting or deselecting functions.Furthermore, the CD 60 is alreadyprepared for the connection of asolar heating system.

Benefits at a glance:

● Suitable for all operating modes:– in mono operation provides

central and DHW heating– in dual-mode, it works in

combination with a second heatgenerator.

● High operational safety andreliability, quiet operation throughhermetically sealed Compliantscroll compressor with double anti-vibration mounts.

● CFC-free, non-flammable andbiologically degradable refrigerantR 407 C.

● Particularly suitable for lowtemperature heating systems, e.g. underfloor heating systems.

● Weather-compensated digitalheating circuit control unit, CD 60,with start-up current limiter andintegral cooling and solar heatingfunctions – up to three loadingsources can be controlled. Menu-guided operation with plain textsupport and integral diagnosticsystem.

● Comprehensive model rangewith output ranging from5.4 to 14.6 kW.

● High performance factorsup to 3.31 (air: 2 °C, flowtemperature: 35 °C).

The perfect complement

At low air temperatures, heatingoutput drops – yet heat demandrises, requiring a supplementaryheat generator to be added to theVitocal 300 air/water heat pump.For the coldest days of the year, aViessmann oil or gas-fired boilerwould be the ideal choice, becauseVitocal control units are optimisedfor the use of a second heat sourcefrom Viessmann. As long as theheat pump supplies sufficientheating energy, the Viessmannboiler will stay off completely. Thisavoids unnecessary heat lossesand saves heating energy. As an alternative to an oil or gas-fired boiler, you could equally wellsupplement the heat pump supplyon very cold days by using anelectric instantaneous water heaterfor a, so-called, mono-energeticapplication.

Page 10: Vitocal / Vitovent 300
Page 11: Vitocal / Vitovent 300

11

Vitocal 350

Air/water heat pump

Flow temperature: up to 65 °C

Output: 9.4 kW

Heat pumps with flow temperatures

up to 65 °C – VITOCAL 350

● Weather-compensated digitalheating circuit control unit CD 60with start-up current limiter andintegral solar heating function – up to three loading sources can becontrolled. Menu-guided operationwith plain text support and integraldiagnostic system.

● Output:– brine/water heat pump 11.0 kW,– water/water heat pump 14.1 kW,– air/water heat pump 9.4 kW.

● High performance factors:– brine/water heat pump (0/35 °C):

4.31,– water/water heat pump: 5.22,– air/water heat pump (2/35 °C):

3.30.

● Annual work factor above 3, evenwith flow temperature 65 °C.

The utilisation of renewableenergies is gaining importance for modernisation projects too.The new Vitocal 350 heat pump canreach flow temperatures up to65 °C, thanks to additional vapourinjection (EVI cycle) in thecompressor circuit.This makes Vitocal 350 ideal, notonly for new buildings, but equallyfor the modernisation of radiatorheating systems in older buildings.

Its high flow temperatures of up to65 °C also allows it to heat up DHWto a temperature of 58 °C. ThusVitocal 350 can offer a high level ofDHW convenience.

The Vitocal 350 heat pump is soefficient it can even be used as soleheat source for central heating andDHW production all the year round(mono-operation).

The Compliant scroll compressorensures not only high operationalreliability, but also very quietoperation.

Subject to system concept, theintegral control function “Naturalcooling” can be utilised. Thismeans that the low temperaturesunder ground or in thegroundwater can be used insummer to cool the building.

This makes Vitocal 350 an idealchoice for utilising natural heatingand cooling in existing homes.

Benefits at a glance:

● Particularly suitable for radiatorheating systems with flowtemperatures up to 65 °C.

● DHW temperature up to 58 °C.

● In mono-mode covers the totalcentral heating and DHWrequirement – all year round (thesame applies to the air/water heatpump).

● High operational safety, reliabilityand quiet operation throughhermetically sealed Compliantscroll compressor with dual anti-vibration mounts.

● CFC-free, non-flammable andbiologically degradable refrigerantR 407 C.

Page 12: Vitocal / Vitovent 300
Page 13: Vitocal / Vitovent 300

13

Vitocal 343

Compact heating tower for

low energy houses

Menu-guided control unit CD 70

Compact heating tower for

low energy houses – VITOCAL 343

The future belongs to houses withlow energy demand, because theyare kind to the environment,minimise CO2 emissions and savenatural resources. This particularlyapplies when renewable energiesare utilised, such as with the Vitocal343 (brine/water heat pump).

Vitocal 343 is a compact completesolution for low energy houses.This means brine/water heat pump,DHW cylinder and all componentsrequired for integrating a solarheating system – on a foot print ofonly 600 x 670 mm.

The heart of Vitocal 343 is theCompliant scroll compressor,already well proven in the Vitocal300 heat pump. The heat pumpmodule is completely enclosedand, therefore, operates with verylow noise emissions.

Hot water heating accounts for asubstantial part of the total energyconsumption of a low energyhouse. The DHW cylinder with 250 litres capacity, which is integralto Vitocal 343 and which provides asecond heat exchanger forconnection to a solar heatingsystem, features high draw-offrates and low standby losses. It,therefore, combines economy withthe highest DHW convenience.

Benefits at a glance:

● Compact heating tower forcentral heating and DHW heating,fully assembled and ready toconnect.

● Footprint of only 600 x 670 mm,side clearances for service are notrequired.

● Ready for connection to a solarheating system. Integral waterconnection, Solar-Divicon andcontrol unit.

● Integral immersion heater withthree stage operation for automaticDHW and heating circuit backup (2, 4, 6 kW).

● Particularly quiet operationthrough fully enclosed heat pump.

● Refrigerant: R 410 A.

● New menu-guided control unitCD 70 including all controlfunctions for weather-compensatedheating, solar circuit and “Naturalcooling”.

● Output: – mono-mode 6 kW,– mono-energetic 12 kW.

● Performance factor: (heating mode) 4.3.

● Maximum temperatures: Heatpump 60 °C, immersion heaterelement 70 °C.

● DHW cylinder capacity: 250 litres.

Menu guided control unit CD 70

CD 70, the new menu-guidedcontrol unit with all functionsnecessary for weather-compensated heating and anintegral solar circuit, also offers thefunction “Natural cooling”. Thisallows the lower undergroundtemperatures to be used on hotsummer days to cool the buildinginterior.

Page 14: Vitocal / Vitovent 300
Page 15: Vitocal / Vitovent 300

Optimum conditions for your home

and finances – VITOVENT 300 –modern domestic ventilation

15

Natural changes of air – essentialfor health, comfort and the well-being of the building itself – arefrequently lacking in low energyhomes, because of their airtightconstruction. The previous practiceof airing by opening windows ishardly controllable and no longerappropriate, as it undermines theintended energy-consciousregulation of heat. For thesereasons, a domestic ventilationsystem should be utilised in lowenergy houses. These change precisely the correctvolume of air, so that windows canstay shut throughout the heatingseason – without sacrificingambient air quality.

How does it work?

Ventilation systems constantlyrefresh the ambient air, removingodours and contaminants. Inaddition, domestic ventilationsystems with heat recoverytransfer heat from spent air to the inrushing fresh air. This lowersthe ventilation heat demandsubstantially – so heating coststumble to a minimum.

Benefits at a glance:

● Provides a comfortable andhealthy ambient climate.

● Saves heating energy andprotects the environment, as theair changes are matched to actualrequirements.

● Convenient, demand-dependentoperation of the domesticventilation via remote control.

● Heat recovery better than 90%reduces the ventilationrequirement to a minimum andreduces heating costs.

● Integral bypass for cool night airduring summer.

● Pollen filters purify the outside air(filter class F6) for improvedconditions inside.

● Fungal growth and buildingdamage through excessivehumidity are prevented.

● Compact design reduces spacerequirements; Vitovent 300 can beinstalled freestanding or wall-mounted.

● Simple and space-savinginstallation through Fastflex flatchannel air distribution ducts.

● Economical DC motors keep theair flow constant, independent ofstatic pressure or air distribution.

Simple filter changing Convenient remote controlFastflex flat channel air

distribution system

Vitovent 300

Vitovent 300 is a compact domesticventilation system with heatrecovery. Exhaust air is routed viaa heat exchanger which transfersthe heat, in the counter currentprinciple, to the inrushing fresh air.This enables more than 90% oflatent heat to be recovered. Thebenefits to you are obvious: fresh,filtered and pre-heated air in allrooms – whilst your windows stayshut. Occupants are not disturbedby noise or dust, and an effectivepollen filter provides clean air tofilter class 6 standard. Even thosewho suffer from allergies can enjoya perfect climate in low energyhouses – any time.

The benefits of Vitovent 300 arealso available outside the heatingseason – thanks to a temperature-controlled bypass circuit, the heatexchanger function, which is notrequired in summer, is linked outand cool night air is channelledinto living spaces.

Page 16: Vitocal / Vitovent 300

Heat from the air:

Vitocal 300 utilises the outside

air heated by the sun.

On colder days, a second heat

source can be used as backup.

Bathr./WCLiving room

DHW cylinder

Cellar

Vitocal 300 Calorifier

Bathr./WCLiving room

Cellar

DHW cylinderVitocal 300

Bathr./WCLiving room

DHW calorifier

Cellar

Vitocal 300 Calorifier

Return wellDelivery well

Intermediate heat exchanger

Flow

Bathr./WCLiving room

DHW calorifier

Cellar

Vitocal 300 Calorifier

Bathr./WCLiving room

Cellar

DHW

cylinder

Vitocal 300 Calorifier

Light duct

Bathr./WCLiving room

Cellar

DHWcylinder

Vitocal 300

Heat from the ground:

Vitocal 300 extracts heat

from underground using

ground probes or ground

collectors and can cover

the entire heating requirement

all year round.

Heat from water:

Vitocal 300 extracts heat from

groundwater which offers a

stable temperature, thereby

achieving permanently high

performance factors – even on

colder days.

Page 17: Vitocal / Vitovent 300

VITOCAL 300VITOCAL 350Brine/water heat pump

VITOCAL 300VITOCAL 350Air/waterheat pump

Version 106 108 110 113 116 110

Vitocal 300 Vitocal 350

Performance factor 3.18 3.18 3.31 3.21 3.18 3.3(Air 2 °C / water 35 °C)

Rated output kW 5.4 7.2 9.3 12.2 14.6 9.4

Cooling output kW 3.7 4.95 6.5 8.4 10.2 6.55

Dimensions (overall)

Length x width x height mm 760 x 1200 x 1510

Version 104 106 108 110 113 116 208 212 216 220 226 232 110

Vitocal 300 Vitocal 300 Vitocal 350

single stage two-stage single stage

Performance factor 4.36 4.57 4.61 4.50 4.59 4.53 4.35 4.56 4.60 4.49 4.57 4.51 4.31(Brine 0 °C / water 35 °C)

Rated output kW 4.8 6.4 8.3 10.8 14.0 16.3 9.6 12.8 16.6 21.6 28.0 32.6 11.0

Cooling output kW 3.7 5.0 6.5 8.4 11.0 12.7 7.4 10.0 13.0 16.8 22.0 25.4 8.45

Dimensions (overall)

Length x width x height mm 650 x 600 x 945 650 x 780 x 1245 650 x 600 x 945

VITOCAL 300Water/waterheat pump

Version two-stage 240 254 268 280

Performance factor

Water 10 °C/water 35 °C 5.6 5.6 5.6 5.6

Brine 0 °C/water 35 °C 4.3 4.3 4.3 4.3

Rated output

as water/water heat pump kW 52.0 73.2 90.2 106.8

as brine/water heat pump kW 39.6 55.6 68.6 81.2

Cooling output

as water/water heat pump kW 42.8 60.0 74.0 87.8

as brine/water heat pump kW 30.4 42.7 52.6 62.3

Dimensions (overall) mm Length: 760 / Width: 1200 / Height: 1505

Vitocal 350 up to 65 °C flow temperature available from July 2003

17

VITOCAL 300VITOCAL 350Water/waterheat pump

Vitocal 350 up to 65 °C flow temperature available from July 2003

Version 104 106 108 110 113 116 208 212 216 220 226 232 110

Vitocal 300 Vitocal 300 Vitocal 350

single stage two-stage single stage

Performance factor 5.48 5.60 5.74 5.68 5.90 5.81 5.46 5.58 5.72 5.66 5.87 5.79 5.22(Brine 0 °C / water 35 °C)

Rated output kW 6.3 8.4 10.9 14.2 18.3 21.5 12.6 16.8 21.8 28.4 36.6 43.0 14.1

Cooling output kW 5.15 6.9 9.0 11.7 15.2 17.8 10.3 13.8 18.0 23.4 30.4 35.6 11.4

Dimensions (overall)

Length x width x height mm 650 x 600 x 945 650 x 780 x 1245 650 x 600 x 945

Vitocal 350 up to 65 °C flow temperature available from July 2003

Page 18: Vitocal / Vitovent 300

Bedroom

Solar collector

Bathroom

Living roomKitchenNursery

Vitocal 343

Cellar

Bedroom Bathr./WC Kitchen Living room

Solar collector

DHW

cylinder

Domestic

ventilation system

Exhaust air

Fresh air

Boiler

Solar control

unit

Vitovent 300 domestic ventilation

system with heat recovery and air

pre-heating for comfortable

ambient conditions all year round;

reduced air heating requirement

and lower heating costs result.

Vitocal 343 Compact heating

tower is a complete solution for

low energy houses.This means:

brine/water heat pump, DHW

cylinder and all components for

solar heating integration in one

housing.

Page 19: Vitocal / Vitovent 300

19

VITOCAL 343

Dimensions (overall)

Length x width x height mm 670 x 600 x 2100

Brine/water heat pump

Rated output kW 6.0

Performance factor (Brine 0 °C/water 35 °C) 4.3

Weight (total) kg 280

DHW cylinder capacity l 250

Output (total) (incl. 6 kW electrical) kW 12

VITOVENT 300

Max. air volume flow (three-stage adjustable) m3/h 50 to 260

Suitable for houses up to m2 180

Power consumption W 10 to 120

Dimensions (overall)

Length mm 525

Width mm 675

Height mm 705

● 4 DN 160 connectors for outside air, extract, ventilation and exhaust air● Remote control unit with time, program selector switch and “filter dirty”

indicator● Balance control● Constant volume flow control● Integral bypass damper

Page 20: Vitocal / Vitovent 300

Your heating contractor:

Subject to technical modifications9446 753 GB 06/2003

Viessmann offers

you a diverse

range of products,

which are uniform

in quality and

adaptable enough

to be able to meet

any demand and

any requirement

Wall-mounted

oil and gas fired

condensing boilers

The Viessmann Group

The Viessmann Group employs approxi-mately 6800 staff worldwide and is oneof the foremost manufacturers of heat-ing equipment. For freestanding boilers,Viessmann is the most successful brandin Europe. The Viessmann brand standsfor competence and innovation. TheViessmann Group offers a comprehen-sive range of top-quality, high-techproducts along with perfectly matchedmodular components. For all their diversity, our products haveone thing in common: a consistentlyhigh standard of quality that is reflectedin operational reliability, energy savings,environmental compatibility and user-friendliness.

Many of our developments point theway forward for the heating sector, bothin terms of conventional heating tech-nologies and in the field of renewableforms of energy, such as solar and heatpump technology.

In all our developments we pursue our philosophy of always achieving the greatest possible benefit: for ourcustomers, the environment and ourpartners, the heating contractors.

The Viessmann Group:

Viessmann Werke

D-35107 Allendorf (Eder)

Tel: + 49 6452 70 - 0

Fax: + 49 6452 70 - 2780

www.viessmann.com

Viessmann UK Office:

Viessmann Limited

Hortonwood 30,Telford

Shropshire,TF1 7YP, GB

Tel: + 44 1952 675000

Fax: + 44 1952 675040

E-Mail: [email protected]