AN ISO 9001 & 14001 COMPANY TENDER DOCUMENT TENDER No: DLI/CON/710/634 dated 04.08.2018 FOR “External & Internal Electrical works including Supply, Installation, Testing & Commissioning of Transformers, Electrical HT/LT Panels, Air-conditioning & Fire Fighting works for 1st Phase (B+G+IV) of Administrative Building of New Town Kolkata Development Authority at Plot No. DG/13, Premises No.04- 3333, Action Area 1D, New Town, Kolkata”. VOLUME III BILL OF QUANTITY

Upload: ngothien

Post on 28-Aug-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: VOLUME III - engineeringprojects.comengineeringprojects.com/Tender/UploadFiles/VOl-III.pdf · power cable directly in duct/hume pipe as per IS : 7098 ... Supply and Erecting of perforated

AN ISO 9001 & 14001 COMPANY

TENDER DOCUMENT

TENDER No: DLI/CON/710/634 dated 04.08.2018

FOR

“External & Internal Electrical works including Supply, Installation, Testing & Commissioning of Transformers, Electrical HT/LT Panels, Air-conditioning & Fire Fighting works for 1st Phase (B+G+IV) of Administrative Building of New

Town Kolkata Development Authority at Plot No. DG/13, Premises No.04-3333, Action Area – 1D, New Town, Kolkata”.

VOLUME – III

BILL OF QUANTITY

Page 2: VOLUME III - engineeringprojects.comengineeringprojects.com/Tender/UploadFiles/VOl-III.pdf · power cable directly in duct/hume pipe as per IS : 7098 ... Supply and Erecting of perforated

Engineering Projects (India) Ltd.

(A Govt. Of India Enterprise)

Abstract Sheet

Tender No: DLI/CON/710/634 dtd. 04.08.2018

Tender for “External & Internal Electrical works including Supply, Installation, Testing & Commissioning of Transformers, ElectricalHT/LT Panels, Air-conditioning& Fire Fighting works for 1st Phase (B+G+IV) of Administrative Building of New Town Kolkata Development Authority at Plot No. DG/13, Premises No.04-3333, Action Area – 1D, New Town Kolkata”.

Sl. No. Item Description Value(in Rs.)

1 HT Sub-Station 10997060.42

2 Generator & AMF panel 9619588.29

3 Air condition system with VRF 24635119.00

4 Compound Lighting 5470262.29

5 Fire 14812025.25

Total 65510055.25

Add Tender Premium-1 @ 8.44% 5529048.66

Total 71039103.91

Add Tender Premium-2 @ 0.40% 284156.41

Total 71323260.32

Add Tender Premium-3 @ 2.00% 1426465.20

Total 72749725.52

Say= 7,27,49,725.00

Total Estimated Value: Rupees Seven Cores Twenty Seven Lakh Forty Nine Thousand Seven Hundred Twenty Five Only.

Note : The quoted price by the bidder shall be inclusive of all taxes and duties including GST

Page 3: VOLUME III - engineeringprojects.comengineeringprojects.com/Tender/UploadFiles/VOl-III.pdf · power cable directly in duct/hume pipe as per IS : 7098 ... Supply and Erecting of perforated

Sl. Item Description Qnty Unit Rate (Rs.) Amount (Rs.)

1 ELECTRICAL SECTION -I ( Sub Station)

Transformer & Accessories

Supply, installation, testing and commissioning of 750KVA, 11/0.433KV, 3 Phase, 4 wire, 50 Hz, ONAN transformer for indoor

duty with a -20% to +5% Off-load tap changer in the step of 1.25%, cable box at primary and secondary end with double float

buchholz relay protection, high winding & oil temparature sensors - Alarm & Trip, and at neutral earthing conductor with

control cabling from transformer to HT Breaker (to trip primary breaker) complete with all fittings, interconnection of control

cables and accessories , first filling of oil as per detailed technical specifications and as required.(Voltamp / ABB / Areva / Tesla)

2 Set 14,99,432.87 29,98,865.74

HT Panel

Supply, delivery, erection, testing and commissioning of Three (3) panel, 630 Amps, 11KV, 3-Phase, 50HZ, metal clad, dead front,

350MVA rupturing capacity Vacuam Circuit Breaker as per the detailed specifications and drawings including connections, etc.

complete with following incommers and outgoings as required.(Siemens / ABB / Areva)

Incommer:

1 No. VCB Pannel having the following.

1 No. 630A, 11KV, 3 Phase, 50HZ, metal clad, dead front, 350 MVA rupturing capacity, Fully drawout type , Vacuum Circuit

Breaker(Breaker Breaking capacity -25KA).

1 No. 11KV/110V resin cast Potential Transformer with HRC fuses.having accuracy class-1 for metering

1 set of Phase indicating lamp with HRC fuses.

1 No. 0-15KV voltmeter with selector switch

1 set of indicating lamps to indicate ON,OFF,TRIP ,Spring Charge & TRIP CIRCUIT HEALTHY.)

2 No. Push Buttom for CLOSE and TRIP.

1 no.Trip /Neutral/Close Switch

1 no.Local/Remote Switch

1 No. 100/5-5A Current Transformer for metering and protection(accuracy class-

-0.5 for metering & 5P10 for protection)

1 No 0-100 Amps ammeter with selector switch.

1 set of CDG 61(2 No.O/C, 1 No. E/R relay (electromagnetic/electrostatic)

1 set of Undervoltage relay and Overvoltage relay.(Electromagnetic)

1 no 30V DC shunt trip coil & 1 no.30V DC closing coil.

1 No. Master Trip relay.(Electromagnetic)

1 No. Power factor meter.

1 no.Trivectormeter

1 no.Frequency Meter

Busbar:

11 KV, 350 MVA, 800 Amps Three Phase busbars of Cu.for Incomer & Outgoing

2 nos.Outgoings:

1 No. VCB Pannel having the following

1 No. 630A, 11KV, 3 Phase, 50HZ, metal clad, dead front, 350 MVA rupturing capacity, Fully drawout type , Vacuum Circuit

Breaker(VCB breaking capacity -25KA)

1 set indicating lamps to indicate ON, OFF, TRIP, SPRING CHARGED, TRIP CIRCUIT HEALTHY.

2 No. Push Buttom for CLOSE and TRIP.

1 no.Trip/Neutral/Close Switch

1 no.Local/Remote Switch

1 No. 50/5-5A Current Transformer for metering and protection.

1 No 0-50 Amps ammeter with selector switch.

1 set of CDG 61(2 No.O/C, 1 No. E/R relay (Electromagnetic/electrostatic).

1 No Master Trip Relay(Electromagnetic).

2 Set ofAuxiliary relay Buchholz,Oil & winding temp Protaction with alarm and trip signals.(Electromagnetic)

1 no.buzar with Push Buttor for common to the Switchboard

H.T. Panel as mentioed above

Electrical Interlocking between HT,LT & Generator set will be done accordingly as per scheme.Necessary scheme will be

intimated at the time of drawing approval.

3 Battery Chager:

Supply, delivery, erection, testing and commissioning of the battery charger panel complete with battery control cabling, etc. as

required.

Rate shall also include provision of minimum 200 AH 30/24 volt SMF.

VRLA Battery including Float cum Boost Thyrister/IGBT controlled.

battery charger with one no. as Hot standby suitable for operation at

240 volt AC 50 Hz supply,

1 No. AC Voltmeter (0 - 500 Volt).

1 No. DC Voltmeter.

1 No. DC Ammeter.

1 set of AC and DC indicating lamps.

1 No. DC Battery charging position indicator.

DCDB with 63A DP MCB as incomer and 16 nos SP MCB as outgoing complete as per specifications and suitable to above.

Control cabling between DC Distribution panel to the HT panel of the Substation with cable size 4C X 2.5 Sqmm. Copper cable.

Battery Charger Panel as mentioned above

1 set 2,23,948.31 2,23,948.31

4 Safety Equipments

Supply and laying of 12 KV grade, 12mm, 1 metre wide anti skid chequered type rubber mat.100 sqmm 869.61 86,961.00

5 Supply and laying of 1.1 KV grade 12mm, 1 metre wide anti skid chequered type rubber mat. 500 sqmm 417.13 2,08,565.00

6 Supply and installation of Fire Buckets 13 litre capacity 4 Nos. duly filled with sand and GI pipe support stand for these buckets

including painting, etc. complete as required.4 Set 1,457.43 5,829.72

7 Supply and fixing shock treatment chart in English, Hindi and local language mounted on 5mm. Thick plywood and 3mm. Thick

plain glass front complete as required.4 Set 325.22 1,300.88

8 Supply and fixing of ISI marked 6.5 kg Co2 type portable fire extinguisher with necessary clamps, supports and trolley in Panel

room approved by ISI complete as required.6 Set 7,374.01 44,244.06

ENGINEERING PROJECTS (INDIA) LIMITED

( A GOVT OF INDIA ENTERPRISE )

Name of the Work : Construction of 1st Phase (B+G+IV) of Administrative Building of New Town Kolkata Development Authority at Plot No. DG/13, Premises No. 04-3333, Action Area - 1D, New Town Kolkata

NIT No. - DLI/CON/710/634 Dated 04.08.2018

BILL OF QUANTITIES

1 set 17,16,938.39 17,16,938.39

2

Page 4: VOLUME III - engineeringprojects.comengineeringprojects.com/Tender/UploadFiles/VOl-III.pdf · power cable directly in duct/hume pipe as per IS : 7098 ... Supply and Erecting of perforated

Sl. Item Description Qnty Unit Rate (Rs.) Amount (Rs.)

9 Supply, storing, handling and fixing in position First Aid Medical Box and an 'Artificial Respirator' complete as per technical

specifications as required.5 Each 522.17 2,610.85

10 Supply and testing of 11KV ISI marked hand gloves 2 Each 517.12 1,034.24

11 Supply, installation, testing and commissioning of self contained emergency light unit consisting of 1X20 watt fluorescent tube

and dry type SMF battery for 1 hour backup complete as required.2 Each 2,012.93 4,025.86

12 H.T. Cables

Supply, laying, testing and commissioning of following sizes of 11KV grade multicore aluminium conductor XLPE armoured

power cable directly in duct/hume pipe as per IS : 7098(contractor to measure exact required quantity before supply as per

installation position) (Nicco / Polycab)

12.1 3C X 240 Sq.mm. 200 M 2,421.98 4,84,396.00

12.2 3C X 120 Sq.mm. 69 M 1,498.84 1,03,419.96

13 H.T. Cable Terminations.

Supplying and making end termination with heat shrinkable jointing kit(outdoor type) with Raychem kits complete with all

accessories including lugs suitable for following size 3 core, XLPE aluminium conductor cable of 11KV grade as required.

13.1 3C X 240 Sq.mm. 1 Each 19,311.20 19,311.20

13.2 3C X 120 Sq.mm. 1 Each 19,311.20 19,311.20

14 Supplying and making end termination with heat shrinkable jointing kit(indoor type) with Raychem kits complete with all

accessories including lugs suitable for following size 3 core, XLPE aluminium conductor cable of 11KV grade as required.

14.1 3C X 240 Sq.mm. 3 Each 12,401.79 37,205.37

14.2 3C X 120 Sq.mm. 4 Each 11,852.35 47,409.40

15 Supply and laying of following sizes non pressure NP2 class(light duty) RCC pipe(300mm) with collar joint with stiff mixture of

cement (1-cement : 2-fine sand) including testing the joints, etc. as per specification and required. 15 Metre 792.85 11,892.75

15.1 Cable Tray

Supply and Erecting of perforated type Hot dip G.I. cable tray of 14G of specific dimensions. The cable tray shall be hung from

ceiling/ fixed to wall with necessary ceiling suspensors, tee, nots, nuts etc, together with tees, bends etc. All necessary required

hard ware for mounting cable tray along with fabricated supports as per site condition shall be included in cable tray rate. The

tray shall be continuously earthed with included in cable tray rate. The tray shall be continuously earthed with 25 x 6 mm GI

Flat. The cost of GI Flat shall be included along with cable tray rates complete as per specification.(Rattan Eng.)

15.2 150 x 75 mm 200 Meter 909.00 1,81,800.00

15.3 300 x 75 mm 150 Meter 1,616.00 2,42,400.00

16 LT CABLES

Supply, Laying of cables on cable trays/Hume pipes/structural supports/underground and cable supports provided, include

unloading, shifting upto site. The scope includes clamping of cables by ready made G.I. spacers, saddles or clamps fabricated out

of GI strip 3 mm thick. (NICCO /POLYCAB /SKYTONE / NATIONAL / GLOSTER/ECKO)

16.1 4C X 16Sq.mm. - Al stranded for Substation & lighting panel 350 Metre 197.96 69,286.00

16.2 3.5C X 300Sq.mm. - Al for FIRE PNL & Rising Main 160 Metre 1,356.43 2,17,028.80

16.3 3.5C X 400Sq.mm. - Al for trf, capacitor pnl, VRF & DG Set 550 Metre 1,732.15 9,52,682.50

17 LT Cable Terminations: Supplying & fixing of double compression type Brass glands & making joint with necessary AL. / CU.

crimping socket of long neck type connecting the same to various equipment like section pillar, switch, starter, motor etc. for

the following sizes:(COMET/ CONNECT WEL/ DOWELS)

17.1 4C X 16Sq.mm. - Al 4 End 104.54 418.16

17.2 3.5C X 300Sq.mm. - Al 8 End 631.76 5,054.08

17.3 3.5C X 400Sq.mm. - Al 32 End 631.76 20,216.32

18 Supplying & finishing cable ends with necessary AL. / CU. crimping socket of long neck type connecting the same to various

equipment like section pillar, switch, starter, motor etc. for the following sizes:(COMET/ CONNECT WEL/ DOWELS)

18.1 4C X 16Sq.mm. - Al 4 Set 99.99 399.96

18.2 3.5C X 300Sq.mm. - Al 8 Set 1,422.59 11,380.72

18.3 3.5C X 400Sq.mm. - Al 32 Set 2,111.91 67,581.12

DISTRIBUTION PANEL

Main L.T panel complete as per Technical Specifications/ data sheets/ SLD and applicable standards.

Supply, delivery, erection, testing and commissioning of LT Panel, cubicle type, totally enclosed, free standing type, dust, damp

and vermin proof panel made up of 14 SWG CRCA sheet, complete with copper busbars, danger notice plate, interconnections

with suitable capacity copper leads / solid copper strips/rods, necessary interlocking, power coat painted and having incoming

and outgoing switchgears as mentioned below and complete as per technical specifications and as required.

1. All ACBs shall have 5 NO + 5 NC contacts

2. All relays to operate at 240Volts, Single phase, 50Hz, AC supply through UPS

Incommer:

2 Nos. ACB Panels each having following.

1 No. 1250A, 415/500V, Rated service short circuit rupturing capacity (Ics) 50 KA, Motorised, Fully Drawout type(EDO), Four

Pole, Air Circuit Breaker with microprocessor based overload, short circuit & earth fault trip including under voltage release and

lockable trip push button. ACB should have Icw=50KA for 1 sec.(L&T / ABB )

Indicating lamps with 2A protection MCBs to indicate OPEN, CLOSE, TRIP for ACB

Push button to CLOSE the ACB.

R, Y, & B Phase indicating lamps with 2A control SP MCBs

1000/5A CTs with CT shorting links for power factor inprovement panel suitable for giving signal to APFCR at less than 10% of

secondary ratio current.

All Incoming ACBs shall have multi function meter - parameters - digital multifunction meter EM6400 or equivalent shall

indicating A / V / KWH / PF / FREQ / DM / VAR with RS-485 port with suitable CTs, CT shorting links.

Busbar:

19

1 Set 23,27,487.43 23,27,487.43

Page 5: VOLUME III - engineeringprojects.comengineeringprojects.com/Tender/UploadFiles/VOl-III.pdf · power cable directly in duct/hume pipe as per IS : 7098 ... Supply and Erecting of perforated

Sl. Item Description Qnty Unit Rate (Rs.) Amount (Rs.)

2000 AMP,50KA, 650 Volts, 3 phase 50 Hz FP Al. bus bars of suitable length - Current ratio shall be 1 sq mm = 0.8 A.

Buscoupler:

1 Nos. ACB Panels each having following.

1 No. 1250A, 415/500V, Rated service short circuit rupturing capacity (Ics) 50 KA, Motorised, Fully Drawout type(EDO), Four

Pole, Air Circuit Breaker with microprocessor based overload, short circuit, Instanteneous & earth fault trip including under

voltage release and lockable trip push button. The ACB should have Icw=35KA for 1 sec.(L&T / ABB ).

1 set of indicating lamps to indicate OPEN, CLOSE, TRIP

Push button to CLOSE the ACB

1 set of meter with ASS and CTs

OUTGOINGS:

5 No. MCCB as per following details / specifications:

630 Amps, 415V, 50KA(Ics) FP MCCB with variable current settings of 0.4 to 1.0 In and having microprocessor based O/L, S/C &

E/F protection release.(Legrand / L&T /ABB/Havells)

Extended rotary operating mechanism with door interlock with defeat feature and padlock facility. MCCB should have spreader

links & phase barriers

Indicating lamps with 2A protection MCBs to indicate OPEN, CLOSE, TRIP for MCCB..

R, Y & B Phase indicating lamps (LED type) with 2A control SP MCBs

3 No. MCCB as per following details / specifications:

500 Amps, 415V, 35KA(Ics) FP MCCB with variable current settings of 0.4 to 1.0 In and having microprocessor based O/L, S/C &

E/F protection release.(Legrand / L&T /ABB/Havells)

Extended rotary operating mechanism with door interlock with defeat feature and padlock facility. MCCB should have spreader

links & phase barriers

Indicating lamps with 2A protection MCBs to indicate OPEN, CLOSE, TRIP for MCCB

R,Y & B phase indicating lamps(LED type)with 2A control SP MCBs.

2 No. MCCB as per following details / specifications:

250 Amps, 415V, 25KA(Ics) FP MCCB with thermal magnetic release having variable current settings of 0.4 to 1.0 In.(Legrand /

L&T /ABB/Havells)

Extended rotary operating mechanism with door interlock with defeat feature and padlock facility. MCCB should have spreader

links & phase barriers.

Indicating lamps with 2A protection MCBs to indicate OPEN, CLOSE, TRIP for MCCB.

R, Y & B Phase indicating lamps (LED type) with 2A control SP MCBs.

2 No. MCCB as per following details / specifications:

150 Amps, 415V, 25KA(Ics) FP MCCB with thermal magnetic release having variable current settings of 0.4 to 1.0 In.(Legrand /

L&T /ABB/Havells)

Extended rotary operating mechanism with door interlock with defeat feature and padlock facility. MCCB should have spreader

links & phase barriers.

Indicating lamps with 2A protection MCBs to indicate OPEN, CLOSE, TRIP for MCCB.

R, Y & B Phase indicating lamps (LED type) with 2A control SP MCBs.

2 No. MCCB as per following details / specifications:

100 Amps, 415V, 25KA(Ics) FP MCCB with thermal magnetic release having variable current settings of 0.4 to 1.0 In.(Legrand /

L&T /ABB/Havells)

Extended rotary operating mechanism with door interlock with defeat feature and padlock facility. MCCB should have spreader

links & phase barriers.

Indicating lamps with 2A protection MCBs to indicate OPEN, CLOSE, TRIP for MCCB.

R, Y & B Phase indicating lamps (LED type) with 2A control SP MCBs.

4 No. MCCB as per following details / specifications:

63 Amps, 415V, 25KA(Ics) FP MCCB with thermal magnetic release having variable current settings of 0.4 to 1.0 In.(Legrand /

L&T /ABB/Havells)

Extended rotary operating mechanism with door interlock with defeat feature and padlock facility. MCCB should have spreader

links & phase barriers.

Indicating lamps with 2A protection MCBs to indicate OPEN, CLOSE, TRIP for MCCB.

R, Y & B Phase indicating lamps (LED type) with 2A control SP MCBs.

All Outgoing MCCBs shall have multi function meter - parameters - digital multifunction meter shall indicating A / V / KWH with

RS-485 port with suitable CTs, CT shorting links.

ASS/VSS : Make - KAYCEE/ L&T.

Main LT Panel as mentioned above (T/N/C switch should be provided all the Incomer/Outgoing/Buscoupler panel)

Electrical Interlocking between HT,LT & Generator set will be done accordingly as per scheme.Necessary scheme will be

intimated at the time of drawing approval.

19.3 Capacitor Panel (250 KVAR)

Supply, installation, testing, and commissioning of M.V. cubicle type, 14 SWG CRCA Sheet, totally enclosed free standing type,

dust, damp and vermin proof capacitor panel complete with busbars, M.V. danger notice plate, ammeter, ammeter selector

switch, indicating lamps, CT's , Extra heavy duty capacitors suitable for non linear loads upto 20% (L&T model MD-XL or

equivalent), contactors suitable for capacitor switching(current limiting contactor circuit to supress switching inrush current)

interconnections with suitable capacity aluminium leads / solid aluminium strips, rods, connection of incoming and outgoing

cables with thimbles, stove enamelled painted and having following incoming and outgoing switchgears complete as required.

Incommer:

1No. 500A, 415/500V , 35KA rupturing capacity, FP Moulded Case Circuit Breaker with thermal magneticx release having varible

current setting of 0.8 to 1.0 In.

Extended rotary operating mechanism with door interlock with defeat feature and padlock facility. MCCB should have spreader

links & phase barriers.

1 set of phase indicating lamps with HRC fuses.

Incoming MCCB shall have multi function meter - parameters - digital multifunction meter shall indicating A / V / PF / VAR with

RS-485 port with suitable CTs, CT shorting links.

Busbar:

630 AMP,35KA, 650 Volts, 3 phase 50 Hz FP Al. bus bars of suitable length - Current ratio shall be 1 sq mm = 0.8 A

Outgoings:

1 No. 100 KVAR capacitor bank each with 250 Amps TPN MCCB, 250A TP contractor suitable for capacitor switching with push

buttons and indicators.(Legrand / L&T /Havells)

2 Set 4,30,027.70 8,60,055.40

19

1 Set 23,27,487.43 23,27,487.43

Page 6: VOLUME III - engineeringprojects.comengineeringprojects.com/Tender/UploadFiles/VOl-III.pdf · power cable directly in duct/hume pipe as per IS : 7098 ... Supply and Erecting of perforated

Sl. Item Description Qnty Unit Rate (Rs.) Amount (Rs.)

1 No. 50 KVAR capacitor bank each with 125 Amps TPN MCCB, 100A TP contractor suitable for capacitor switching with push

buttons and indicators.(Legrand / L&T /Havells) suitable for capacitor switching with push buttons and indicators.(Legrand / L&T

/Havells)

1no.40KVAR capacitor bank each with 100Amps TPN MCCB,100A TP contractor suitable for capacitor switching with push

button and indicators (Legrand/L&T/Havells)

1 No. 30 KVAR capacitor bank each with 63 Amps TPN MCCB, 63A TP contractor suitable for capacitor switching with push

buttons and indicators.(Legrand / L&T /Havells)

1 No. 20 KVAR capacitor bank each with 63 Amps TPN MCCB, 63A TP contractor suitable for capacitor switching with push

buttons and indicators.(Legrand / L&T /Havells)

1 No. 10 KVAR capacitor bank each with 32 Amps TPN MCCB, 32A TP contractor

suitable for capacitor switching with push buttons and indicators.(Legrand / L&T /Havells)

1 No. Electronic type, microprocessor based, Automatic power factor correction relay in 8 steps

1,09,73,060.42

2 Set 4,30,027.70 8,60,055.40

Page 7: VOLUME III - engineeringprojects.comengineeringprojects.com/Tender/UploadFiles/VOl-III.pdf · power cable directly in duct/hume pipe as per IS : 7098 ... Supply and Erecting of perforated

Sl. Item Description Qnty Unit Rate (Rs.) Amount (Rs.)

1 Electrical Section II (Generator & AMF Panel )

LT cables

Supply ,Laying of cables on cable trays/Hume pipes/structural supports/undergrounds and cable

supports provided ,include unloading ,shifting upto site.The scope includes clamping of cables by

ready made G.I spacers,saddles or clamps fabricated out of GI strip 3 mm

thick.(Polycab/Havells/KEI)

3.5CX400sq.mm -for DG set

650 Metre 1,732.51 11,26,131.50

2 LT Cable Terminations

Supplying & fixing of double compression type Brass glands & making joint with necessary AL. / CU.

crimping socket of long neck type connecting the same to various equipment like section pillar,

switch, starter, motor etc. for the following sizes:(COMET/ CONNECT WEL/ DOWELS).

3.5C X 400Sq.mm. - Al

32 End 631.76 20,216.32

3 Supplying & finishing cable ends with necessary AL. / CU. crimping socket of long neck type

connecting the same to various equipment like section pillar, switch, starter, motor etc. for the

following sizes:(COMET/ CONNECT WEL/ DOWELS).

3.5C X 400Sq.mm. - Al32 End 2,111.91 67,581.12

DG Set & accessories

Supply, installation, testing and commissioning of sound proof 750 KVA Diesel Generator set

comprising of water cooled radiator type, Diesel Engine with rated capacity of suitable BHP at 1500

rpm, direct injection type, 4 stroke, with suitable no. cylinders coupled to 750 KVA brushless type

415 Volts, 50HZ, self exciting Alternator with suitable size of flexible coupling and following main

components, complete with all accessores conforming to technical specifications and as required.

Make :Kirloskar / Jackson / Starling & Wilson.

Cooling System : water cooled radiator type.

Exhaust System : Pipe, Chimney, silencer and supports (as approved by Pollution Control Board /

Local Authorities ).

Fuel system : Day tank (990 litres-2 nos.) and their interconnecting piping system.

Lube oil system.

Air system.

Electronic Governer.

Starting System.

Coupling arrangement.

safety controls.

Instrument panel for engine.

Control panel with metering, interlocks and annunciations complete as per specifications.

Batteries, Boost and trickle battery charger.

Provision of Busduct connection from alternator terminals to AMF Panel, control cable, neutral and

equipment earthing complete as required.

Spring loaded cushy pads, foundation bolts, etc

This includes protection relays, meters etc complete. control cabling from AMF

DG set mentioned as above panel.

panel to DG set & LT panels is deemed to be included in this item.

AMF - PANEL (FOR 750 KVA ABOVE DG SET)

Supply, installation, testing and commissioning of M.V. cubicle type totally enclosed free standing

type, dust, damp, and vermin proof capacitor panel complete with busbars, M.V. damper notice

plate, ammeter, ammeter selector switch, voltmeter, voltmeter selector switch, PF meter

indicating lamps, CTs,

interconnections, interlocking between two feeders and bus coupler, with suitable capacity

aluminium leads / solid alumionium strips / rods, connection of incoming & outgoing cables with

thimbles, stove enamelled painted and having following incoming and outgoing switchgears and as

per technical bapecifications & as required.1 Set 84,05,659.35 84,05,659.35

4

ENGINEERING PROJECTS (INDIA) LIMITED

( A GOVT OF INDIA ENTERPRISE )

Name of the Work : Construction of 1st Phase (B+G+IV) of Administrative Building of New Town Kolkata Development Authority at Plot No. DG/13, Premises No. 04-3333, Action

Area - 1D, New Town Kolkata

NIT No. - DLI/CON/710/634 Dated 04.08.2018

BILL OF QUANTITIES

Page 8: VOLUME III - engineeringprojects.comengineeringprojects.com/Tender/UploadFiles/VOl-III.pdf · power cable directly in duct/hume pipe as per IS : 7098 ... Supply and Erecting of perforated

1 No. ACB Panels each having following.

1 No. 1250A, 415/500V, rated service short circuit rupturing capacity (Ics) 50 KA, mororised, fully

drawout type(EDO), four pole, Air Circuit Breaker with microprocessor based overload, short

circuit & earth fault trip including under voltage release and lockable trip push button ACB should

have Icw=50KA for 1 sec.

1 set of indicating lamps with 2A protection MCBs to indicate OPEN, CLOSE, TRIP for ACB.

Push button to CLOSE the ACB.

R, Y & B Phase indicating lamps (LED type) with 2A control SP MCBs.

Incoming ACB shall have multi function meter - parameters - digital multifunction meter shall

indicating A / V / KWH with RS-485 port with suitable CTs, CT shorting links.

AMF Cubicle

1 No. frequency meter (45-55 HZ.)

1 set under voltage relay.

1set over voltage relay.

1 set under frequency relay.

1 set of Master trip / supervisory relay.

1 set of battery charger (with tricle and boost charger.).

1 set of DC voltmeter and ammeter.

1 set of Reverse power and Reactive power relay.

1 set R, Y, B, Breaker ON/OFF & other fault indication lamps.

1 set 8 window Alarm annunciator with separate hooter, accept, reset and rest push button.

1 No. Hooter.

1 No. Engine Cranking Relay.

1 set of Main supply voltage monitor, alternate voltmeter monitor and Engine starting relays.

1 set of Auxiliary relays, timer, push button and control fuses.

ENCLOSURE

Fabrication, PVC sleeving, control/ power wiring and necessary hardware for complete AMF Panel

Total of DG Set & AMF Panel.

Electrical Interlocking between HT,LT & Generator set will be done accordingly as per

scheme.Necessary scheme will be intimated at the time of drawing approval.

96,19,588.29

1 Set 84,05,659.35 84,05,659.35

4

Page 9: VOLUME III - engineeringprojects.comengineeringprojects.com/Tender/UploadFiles/VOl-III.pdf · power cable directly in duct/hume pipe as per IS : 7098 ... Supply and Erecting of perforated

Sl. Item Description Qnty Unit Rate (Rs.) Amount (Rs.)

1.0 Electrical Section III ( AIR-CONDITIONING SYSTEM)

Supply, Laying of cables on cable trays/Hume pipes/structural supports/underground and cable

supports provided, include unloading, shifting upto site. The scope includes clamping of cables by

ready made G.I. spacers, saddles or clamps fabricated out of GI strip 3 mm thick. (KEI/POLYCAB

/Havells)

0.00

1.1 3.5C X 95Sq.mm. - Al basement ventilation PNL 120 Metre 532.27 63,872.40

1.2 3.5C X 400Sq.mm. - Al for VRF PNL 550 Metre 1,732.51 9,52,880.50

2.0 LT Cable Terminations

Supplying & fixing of double compression type Brass glands & making joint with necessary AL. / CU.

crimping socket of long neck type connecting the same to various equipment like section pillar,

switch, starter, motor etc. for the following sizes:(COMET/ CONNECT WEL/ DOWELS)

2.1 3.5C X 95Sq.mm. - Al 6 End 324.21 1,945.26

2.2 3.5C X 400Sq.mm. - Al 32 End 631.76 20,216.32

3.0 Supplying & finishing cable ends with necessary AL. / CU. crimping socket of long neck type

connecting the same to various equipment like section pillar, switch, starter, motor etc. for the

following sizes:(COMET/ CONNECT WEL/ DOWELS)

3.1 3.5C X 95Sq.mm. - Al 6 End 349.97 2,099.82

3.2 3.5C X 400Sq.mm. - Al 32 End 2,111.91 67,581.12

VRF Main Panel

Supply, installation, testing and commissioning of following outdoor type with sloping canopy on

the top, double door, M.V cubicle type totally enclosed, 14 SWG CRCA Sheet, IP-54 protected, free

standing type, dust, damp and vermin proof, Distribution Board/Panel complete with busbars, M.V.

danger notice plate, interconnections with suitable capacity aluminium leads/solid aluminium

strips/rods, connection of incomming and outgoing cables with thimbles, powder coat painted and

having following incoming and outgoing switchgears complete as required.

Incommer:

630 Amps, 415V, 50KA(Isc), FP MCCB with thermal magnetic release having variable current setting

of 0.8 to 1.0 In.

Extended rotary operating mechanism with door interlock with defeat feature and padlock facility.

MCCB should have spreader links & phase barriers.

1 set of phase indicating lamps with 2A SP control MCB.

Incoming MCCB shall have multi function meter - parameters - digital multifunction meter shall

indicating A / V with RS-485 port with suitable CTs, CT shorting links.

Busbar:

1000 AMP,50KA, 650 Volts, 3 phase 50 Hz FP Al. bus bars of suitable length - Current ratio shall be

1 sq mm = 0.8 A

Outgoings:

4 sets of the following:

150 Amps, 415V, 25KA(Isc), FP MCCB with thermal magnetic release having variable current setting

of 0.8 to 1.0 In.

1 set of phase indicating lamps with 2A SP control MCB.

1 No. 0-200 Amps ammeter with selector switch and CT's 200/5A.

3 sets of the following:

100 Amps, 415V, 10KA(Isc), FP MCCB with phase indicating lamps.

1 set of phase indicating lamps with 2A SP control MCB.

1 No. 0-100 Amps ammeter with selector switch and CT's 100/5A.

2 sets of the following:

63 Amps, 415V, 10KA(Isc), FP MCB with phase indicating lamps.

1 set of phase indicating lamps with 2A SP control MCB.

1 No. 0-100 Amps ammeter with selector switch and CT's 100/5A.

All MCBs are C-series type.

1 Set 2,66,640.00 2,66,640.00

4.0

ENGINEERING PROJECTS (INDIA) LIMITED

( A GOVT OF INDIA ENTERPRISE )

Name of the Work : Construction of 1st Phase (B+G+IV) of Administrative Building of New Town Kolkata Development Authority at Plot No. DG/13, Premises No. 04-3333,

NIT No. - DLI/CON/710/634 Dated 04.08.2018

BILL OF QUANTITIES

Page 10: VOLUME III - engineeringprojects.comengineeringprojects.com/Tender/UploadFiles/VOl-III.pdf · power cable directly in duct/hume pipe as per IS : 7098 ... Supply and Erecting of perforated

Basement Ventilation Panel:

Supply, installation, testing and commissioning of following M.V cubicle type totally enclosed, 14

SWG CRCA Sheet, IP-54 protected, free standing type, dust, damp and vermin proof, Distribution

Board/Panel complete with busbars, M.V. danger notice plate, interconnections with suitable

capacity aluminium leads/solid aluminium strips/rods, connection of incomming and outgoing

cables with thimbles, powder coat painted and having following incoming and outgoing

switchgears complete as required.

Incommer:

150 Amps, 415V, 25KA(Isc), FP MCCB with thermal magnetic release having variable current setting

of 0.8 to 1.0 In.

Extended rotary operating mechanism with door interlock with defeat feature and padlock facility.

MCCB should have spreader links & phase barriers.

1 set of phase indicating lamps with HRC fuses.

Incoming MCCB shall have multi function meter - parameters - digital multifunction meter shall

indicating A / V with RS-485 port with suitable CTs, CT shorting links.

Busbar:

200 AMP,25KA, 650 Volts, 3 phase 50 Hz FP Al. bus bars of suitable length - Current

ratio shall be 1 sq mm = 0.8 A.

Outgoings:

3 set of the following (Axial flow exhaust fan).

32 Amps, 415V, 25KA(Isc), FP MCCB with thermal magnetic release having variable current setting

of 0.8 to 1.0 In.

Extended rotary operating mechanism with door interlock with defeat feature and padlock facility.

MCCB should have spreader links & phase barriers.

1 No. 3 Phase, DOL Starter for 7.5KW, pump motor with TP contactors, thermal overload relay,

Timer, Local Push Push Buttons and Auto-manual selector switch.

Single Phase preventer.

1 set of phase indicating lamp bwith 2A SP control MCBs.

Indicating Lamps for ON / OFF / TRIP indication with 2A SP control MCBs.

1 No. 0-100 Amps ammeter with selector switch and CT's 100/5A.

4.4 7 set of the following (Jet Fan)

32 Amps, 415V, 25KA(Isc), FP MCCB with thermal magnetic release having variable current setting

of 0.8 to 1.0 In.

Extended rotary operating mechanism with door interlock with defeat feature and padlock facility.

MCCB should have spreader links & phase barriers.

1 No. 3 Phase, DOL Starter for 3.7KW, pump motor with TP contactors, thermal overload relay,

Timer, Local Push Push Buttons and Auto-manual selector switch.

Single Phase preventer.

1 set of phase indicating lamp with 2A SP control MCBs.

Indicating Lamps for ON / OFF / TRIP indication with 2A SP control MCBs.

1 No. 0-100 Amps ammeter with selector switch and CT's 100/5A.

All Outgoing MCCBs shall have multi function meter - parameters - digital multifunction meter shall

indicating A / V with RS-485 port with suitable CTs, CT shorting links.

1 Set 5,71,188.33 5,71,188.33

5.0 Supply of Aircooled Digital Scroll VRF SYSTEM Unit with R 410a Refrigerant, Aircooled Condenser

along with inbuilt microprocessor panel.

OUTDOOR UNIT

5.1 63 HP - GROUND FLOOR 1 Each 14,05,420.05 14,05,420.05

5.2 12 HP - GROUND FLOOR 1 Each 3,59,455.97 3,59,455.97

5.3 63 HP - FIRST FLOOR 1 Each 14,05,420.05 14,05,420.05

5.4 57 HP - SECOND FLOOR 1 Each 13,32,695.00 13,32,695.00

5.5 54 HP - THIRD FLOOR 1 Each 1,30,949.53 1,30,949.53

5.6 50 HP - FOURTH FLOOR 1 Each 12,82,650.51 12,82,650.51

6.0 VRF INDOOR UNITS

6.1 COMPACT CASSETTE UNIT 0.6 TR 8 Each 33,979.43 2,71,835.44

6.2 COMPACT CASSETTE UNIT 0.6 TR 16 Each 34,277.38 5,48,438.08

6.3 LARGE CASSETTE UNIT 2.8 TR 4 Each 48,876.93 1,95,507.72

6.4 LARGE CASSETTE UNIT 2.3 TR 3 Each 42,089.73 1,26,269.19

6.5 LARGE CASSETTE UNIT 1.5 TR 1 Each 41,098.92 41,098.92

6.6 WALL MOUNTED UNIT 1.0 TR 6 Each 20,999.92 1,25,999.52

6.7 WALL MOUNTED UNIT 0.8 TR 4 Each 20,909.02 83,636.08

6.8 DUCTED UNIT 8.0 TR 10 Each 63,753.22 6,37,532.20

6.9 DUCTED UNIT 6.0 TR 6 Each 60,122.27 3,60,733.62

6.1 DUCTED UNIT 5.0 TR 6 Each 57,703.32 3,46,219.92

6.1 DUCTED UNIT 4.0 TR 11 Each 43,272.44 4,75,996.84

1 Set 2,66,640.00 2,66,640.00

4.0

Page 11: VOLUME III - engineeringprojects.comengineeringprojects.com/Tender/UploadFiles/VOl-III.pdf · power cable directly in duct/hume pipe as per IS : 7098 ... Supply and Erecting of perforated

6.1 DUCTED UNIT 3.0 TR 6 Each 34,540.99 2,07,245.94

6.1 5.5 TR TREATED FRESH AIR UNIT 2 Each 47,614.43 95,228.86

6.1 3.5 TR TREATED FRESH AIR UNIT 2 Each 41,843.29 83,686.58

6.2 SUPPLY OF IMPORTED REFNET JOINTS 79 Each 7,434.61 5,87,334.19

6.2 CORDLESS CONTROLLER 42 Each 915.06 38,432.52

6.2 CORDED CONTROLLER 39 Each 3,139.08 1,22,424.12

6.2 2.0 TR (3 STAR) NON VRF STAND ALONE SPLIT UNIT FOR SERVER ROOM 3 Each 45,450.00 1,36,350.00

7.0 Price for Supply Installation & Commissioning of Ancillary Items for VRF

7.1 Installation & Commissioning of Digital Scroll VRF Units , with outdoor mounting, pressure testing,

nitrogen flushing etc16 Each 23,583.50 3,77,336.00

7.2 REF ( R - 410 ) VRF 130 Kg 1,959.40 2,54,722.00

7.3 V I Pads- VRF 16 Set 686.80 10,988.80

7.4 Installation of VRF Indoor Units 85 Each 1,767.50 1,50,237.50

7.5 Installation of stand alone split unit including copper pipe, control cable between indoor &

outdoor units, refrigerant gas etc.3 Each 4,913.65 14,740.95

7.6 Installation of Axial Fan units 10 Each 3,928.90 39,289.00

7.7 Installation of jet fan units 12 Each 2,060.40 24,724.80

7.8 installation of co sensor 4 Each 1,572.57 6,290.28

7.9 Supply and Installation of imported REFNET JOINTS 1 LOT 38,814.30 38,814.30

7.1 Refrigerant Piping with insulation

Suction/ Liquid line with Nitrile rubber insulation

7.1 1 3/8" OD 140 Rmt 1,920.01 2,68,801.40

7.1 15/8" OD 145 Rmt 2,232.10 3,23,654.50

7.1 11/8" OD 200 Rmt 1,395.82 2,79,164.00

7.1 7/8" OD 285 Rmt 1,094.84 3,12,029.40

7.2 5/8" OD 180 Rmt 805.98 1,45,076.40

7.2 3/4" OD 320 Rmt 968.59 3,09,948.80

7.2 3/8" OD 160 Rmt 507.02 81,123.20

7.2 1/2" OD 485 Rmt 604.99 2,93,420.15

7.2 1/4" OD 240 Rmt 369.66 88,718.40

8.0 HDPE Drain piping with insulation

8.1 40 mm. 100 Rmt 298.96 29,896.00

8.2 32 mm 200 Rmt 259.57 51,914.00

8.3 25 mm 400 Rmt 219.17 87,668.00

9.0 Electricals/Cables

Control Cable 2C x 1.5 sqmmfor VRF unit1400 Rmt 158.57 2,21,998.00

10.0 GSS Ducting 24G with hangers, supports etc.

10.1 24 G 1050 Sqmtr 785.78 8,25,069.00

10.2 22 G 300 Sqmtr 914.05 2,74,215.00

10.3 DUCT THERMAL INSULATION WITH13 MM AL. FOIL FACED GLASS WOOL (TAIL END) 750 Sqmtr 874.66 6,55,995.00

10.4 Duct Acoustic Insulation with 12 mm thick FGP (48Kg/cum) RP Tissue + 36g Aluminium Perforated

Sheet200 Sqmtr 661.55 1,32,310.00

10.5 Air distribution Discrete Grilles / Diffusers

10.6 GI Duct Dampers 10 Smt 4,484.40 44,844.00

10.7 Supply air grilles/diffusers air grille with VCD and air box 20 Smt 9,039.50 1,80,790.00

10.8 Return air grilles/diffusers air grille with VCD 28 Smt 8,682.97 2,43,123.16

10.9 Fresh air packaged with BIRD SCREEN/COWL/DAMPER 18 Each 4,129.89 74,338.02

10.10 Flexible fire retardent canvass connection 43 Each 2,161.40 92,940.20

11.0 BASEMENT VENTILLATION SYSTEM

Axial fan 800mm Dia Tube axial Type Fan is suitable for 3~, 400 V, 50 Hz power supply and for

300°C & 2 hrs operation.

11.1 30000 CMH 10 Each 1,26,250.00 12,62,500.00

11.2 315mm dia Jet Fan is suitable for 3~, 400 V, 50 Hz power supply and for 300°C & Hrs operation. CFD

analysis price is Included in our offer.12 Each 60,600.00 7,27,200.00

11.3 CO SENSOR 8 Each 25,250.00 2,02,000.00

12.0 Supply, Laying of cables on cable trays/Hume pipes/structural supports/underground and cable

supports provided, include unloading, shifting upto site. The scope includes clamping of cables by

ready made G.I. spacers, saddles or clamps fabricated out of GI strip 3 mm thick. (Havells /POLYCAB

/KEI)

12.1 3.5C X 16Sq.mm. - PVC/Cu ARM, stranded, from VRF Panel to unit. 120 Metre 1,300.88 1,56,105.60

12.2 3.5C X 25Sq.mm. - PVC/Cu ARM, stranded, from VRF Panel to unit. 250 Metre 1,761.44 4,40,360.00

12.3 3.5C X 120Sq.mm. - PVC, Al, stranded as incommer from Rising Main 320 Metre 1,037.27 3,31,926.40

12.4 3.5C X 150Sq.mm. - PVC, Al, stranded as incommer from Rising Main 80 Metre 1,203.92 96,313.60

Page 12: VOLUME III - engineeringprojects.comengineeringprojects.com/Tender/UploadFiles/VOl-III.pdf · power cable directly in duct/hume pipe as per IS : 7098 ... Supply and Erecting of perforated

13.0 Supplying & fixing of double compression type Brass glands & making joint with necessary AL. / CU.

crimping socket of long neck type connecting the same to various equipment like section pillar,

switch, starter, motor etc. for the following sizes:(COMET/ CONNECT WEL/ DOWELS)

13.1 4C X 16Sq.mm. - Cu 8 End 104.54 836.32

13.2 3.5C X 25Sq.mm. - Cu 24 End 160.59 3,854.16

13.3 3.5C X 120Sq.mm. - Al 8 End 324.21 2,593.68

13.4 3.5C X 150Sq.mm. - Al 2 End 324.21 648.42

14.0 Supplying & finishing cable ends with necessary AL. / CU. crimping socket of long neck type

connecting the same to various equipment like section pillar, switch, starter, motor etc. for the

following sizes:(COMET/ CONNECT WEL/ DOWELS)

14.1 4C X 16Sq.mm. - Cu 8 End 99.99 799.92

14.2 3.5C X 25Sq.mm. - Cu 24 End 125.75 3,018.00

14.3 3.5C X 120Sq.mm. - Al 8 End 452.99 3,623.92

14.4 3.5C X 150Sq.mm. - Al 2 End 477.23 954.46

15.0 VRF Panel (Type - 1)

Supply, installation, testing and commissioning of following outdoor type Distribution Board with

sloping canopy on the top, IP-65 protected, double door, M.V. cuble type totally enclosed, 14 SWG

CRCA Sheet, free standing type, dust, damp and vermin proof, MV Panel complete with busbars,

M.V. danger notice plate, interconnections witrh suitable capacity aluminium leads/solid

aluminium strips/rods, connection of incomming and outgoing cables with thimbles, stove

enamelled painted and having following incomming and outgoing switchgears complete as

required for VRF Panel.

Incommer:

125 Amps, 415V, 25KA(Isc), FP MCCB with thermal magnetic release having variable current setting

of 0.8 to 1.0 In.

Extended rotary operating mechanism with door interlock with defeat feature and padlock facility.

MCCB should have spreader links & phase barriers.

1 set of phase indicating lamps with HRC fuses.

Incoming MCCB shall have multi function meter - parameters - digital multifunction meter shall

indicating A / V with RS-485 port with suitable CTs, CT shorting links.

Busbar:

200 AMP,25KA, 650 Volts, 3 phase 50 Hz FP Al. bus bars of suitable length - Current ratio shall be 1

sq mm = 0.8 A

Outgoings:

4 Nos. 50 Amps 415V, FP MCB, 10KA with phase indicating lamps.

1 No. 0-100 Amps ammeter with selector switch and CT's 100/5A with each feeder.

All MCBs are C-series type.

VRF Panel (Type - 1) as above.

6 set 2,02,000.00 12,12,000.00

VRF Panel (Type - 2)

Supply, installation, testing and commissioning of following outdoor type Distribution Board with

sloping canopy on the top, IP-65 protected, double door, M.V. cuble type totally enclosed, 14 SWG

CRCA Sheet, free standing type, dust, damp and vermin proof, MV Panel complete with busbars,

M.V. danger notice plate, interconnections witrh suitable capacity aluminium leads/solid

aluminium strips/rods, connection of incomming and outgoing cables with thimbles, stove

enamelled painted and having following incomming and outgoing switchgears complete as

required for VRF Panel.

Incommer:

160 Amps, 415V, 25KA(Isc), FP MCCB with thermal magnetic release having variable current setting

of 0.8 to 1.0 In.

Extended rotary operating mechanism with door interlock with defeat feature and padlock facility.

MCCB should have spreader links & phase barriers.

1 set of phase indicating lamps with HRC fuses

Incoming MCCB shall have multi function meter - parameters - digital multifunction meter shall

indicating A / V with RS-485 port with suitable CTs, CT shorting links.

Busbar:

250 AMP,25KA, 650 Volts, 3 phase 50 Hz FP Al. bus bars of suitable length - Current ratio shall be 1

sq mm = 0.8 A.

Outgoings:

5 Nos. 50 Amps 415V, FP MCB, 10KA with phase indicating lamps.

1 No. 0-100 Amps ammeter with selector switch and CT's 100/5A with each feeder.

All MCBs are C-series type.

VRF Panel (Type - 1) as above

17.0 OTHER FITTING

17.1 32A FP SFU ISOLATOR (for 12HP outdoor unit at Gnd Fl. ) Make : Laygrad 1 No. 2,020.00 2,020.00

17.2 Supply and fixing 250 Volt , 6-10A per way, (2+6) way SPN MCBDB with SS enclosure double door

with IP 42/43 protrction with 1 no 40 A DP isolator as a incomer and 5 nos SPMCBs (C curve 10 KA)

as outgoing concelled in wall after cutting the wall and mending good damages to original finish

including interconnection with suitable size of copper wire and neutral link & protrction for

earthing attachment . Make : Legrand.

1 No. 3,354.21 3,354.21

18.0 Electrical Rising main & Tap off boxes for VRF

1 set 2,27,250.00 2,27,250.00

16.0

Page 13: VOLUME III - engineeringprojects.comengineeringprojects.com/Tender/UploadFiles/VOl-III.pdf · power cable directly in duct/hume pipe as per IS : 7098 ... Supply and Erecting of perforated

18.1 Supply, erection, testing and commissioning of 1000 Amps, FP internally earthed Al. Rising Main

System, IP54, 50KA breaking capacity along with all necessary fabrication of supports and other

accessories works complete as per specification, through the shaft/ceiling/wall of different floor as

required including end feed units with MCCB & tap off boxes of rating as follows at every floor . All

joints / tees bends / phase change over boxes etc are deemed to be included in the supply.

Arrangement for future extention arrangement upto eight floor has to included and complete as

required of make MDS-Legrand/C&S or approved equivalent.

35 Mtr. 25,425.74 8,89,900.90

18.2 End Feed Unit, 1000A, ACB, 50KA 1 Each 1,45,736.94 1,45,736.94

18.3 Tap Off boxes, 160A, 25KA for Gnd Floor 1 Each 43,680.48 43,680.48

18.4 Tap Off boxes, 125A, 25KA for 1st Fl, 2nd Fl, 3rd Fl & 4th Fl. 4 Each 41,072.66 1,64,290.64

19.0 BASEMENT VENTILATION SYSTEM

LT CABLES

Supply, Laying of cables on cable trays/Hume pipes/structural supports/underground and cable

supports provided, include unloading, shifting upto site. The scope includes clamping of cables by

ready made G.I. spacers, saddles or clamps fabricated out of GI strip 3 mm thick. (Havells /POLYCAB

/KEI)

19.1 3C X 2.5 Sq.mm. - PVC/Cu ARM, stranded, for Jet Fan. 300 Metre 341.38 1,02,414.00

19.2 3C X 10 Sq.mm. - PVC, Al, stranded, for Axial Fan 250 Metre 310.07 77,517.50

19.3 3.5C X 150 Sq.mm. - PVC, Al, stranded, as incommer. 70 Metre 1,203.92 84,274.40

20.0 Cutting channel of 40mm X 40mm size on masonry wall incl. S&F heavy gauge 19 mm dia 3 mm

thick polythene pipe by means of iron hooks and supplying and drawing 18 SWG GI Wire fish wire

incl. mending good damages to building works

1400 RM 74.49 1,04,286.00

21.0 Supplying and Drawing 1.1 KV, 2 x 22/0.3 (1.5 sqmm), single core, stranded, 'FR' PVC insulated&

unsheathedsingle core stranded copper wire (approved make) of the following sizes in the prelaid

19mm dia 3mm thick polythene pipe and by the prelaid 18 SWG GI Wire fish wire and making necy.

connection as required for VRF unit/ CO Sensor.

1400 RM 40.40 56,560.00

22.0 Supplying & fixing of double compression type Brass glands & making joint with necessary AL. / CU.

crimping socket of long neck type connecting the same to various equipment like section pillar,

switch, starter, motor etc. for the following sizes:(COMET/ CONNECT WEL/ DOWELS)

22.1 3C X 2.5Sq.mm. - PVC/Cu ARM, stranded, for Jet Fan. 24 End 59.09 1,418.16

22.2 3C X 10Sq.mm. - PVC, Al, stranded, for Axial Fan 20 End 104.54 2,090.80

22.3 3.5C X 150Sq.mm. - PVC, Al, stranded, as incommer. 2 End 324.21 648.42

23.0 Supplying & finishing cable ends with necessary AL. / CU. crimping socket of long neck type

connecting the same to various equipment like section pillar, switch, starter, motor etc. for the

following sizes:(COMET/ CONNECT WEL/ DOWELS)

23.1 3C X 2.5Sq.mm. - PVC/Cu ARM, stranded, for Jet Fan. 24 set 52.52 1,260.48

23.2 3C X 10Sq.mm. - PVC, Al, stranded, for Axial Fan 20 set 72.72 1,454.40

23.3 3.5C X 150Sq.mm. - PVC, Al, stranded, as incommer. 2 set 531.26 1,062.52

2,46,35,119.19

Page 14: VOLUME III - engineeringprojects.comengineeringprojects.com/Tender/UploadFiles/VOl-III.pdf · power cable directly in duct/hume pipe as per IS : 7098 ... Supply and Erecting of perforated

Sl. Item Description Qnty Unit Rate (Rs.) Amount (Rs.)

1 Electrical Section IV ( COMPOUND LIGHTING )

Supply, Laying of cables on cable trays/Hume pipes/structural supports/underground and cable

supports provided, include unloading, shifting upto site. The scope includes clamping of cables by

ready made G.I. spacers, saddles or clamps fabricated out of GI strip 3 mm thick. (Havells /POLYCAB

/KEI)

1.1 3C X 2.5Sq.mm. - PVC/Cu ARM, stranded, for Campus Lighting pnl outdoor lighting 500 Metre 127.26 63,630.00

1.2 4C X 10Sq.mm. - Al stranded for Campus Lighting pnl outgoing 500 Metre 105.04 52,520.00

1.3 4C X 16Sq.mm. - Al stranded for Substation & lighting pnl 350 Metre 139.38 48,783.00

2 Supplying & fixing of double compression type Brass glands & making joint with necessary AL. / CU.

crimping socket of long neck type connecting the same to various equipment like section pillar,

switch, starter, motor etc. for the following sizes:(COMET/ CONNECT WEL/ DOWELS)

2.1 4C X 10Sq.mm. - Al, 20 End 69.69 1,393.80

2.2 4C X 16Sq.mm. - Al 4 End 69.69 278.76

3 Supplying & finishing cable ends with necessary AL. / CU. crimping socket of long neck type

connecting the same to various equipment like section pillar, switch, starter, motor etc. for the

following sizes:(COMET/ CONNECT WEL/ DOWELS)

3.1 4C X 10Sq.mm. - Al, 20 End 48.48 969.60

3.2 4C X 16Sq.mm. - Al 4 End 66.66 266.64

4 Campus / Outdoor Lighting Panel

Supply, installation, testing and commissioning of following outdoor type Lighting Distribution

Board with Synchronous Timer / Timer Circuit for automatic controlling, sloping canopy on the top,

IP-65 protected, double door, M.V. cuble type totally enclosed, 14 SWG CRCA Sheet, free standing

type, dust, damp and vermin proof, MV Panel complete with busbars, M.V. danger notice plate,

interconnections witrh suitable capacity aluminium leads/solid aluminium strips/rods, connection

of incomming and outgoing cables with thimbles, stove enamelled painted and having following

incomming and outgoing switchgears complete as required for campus / outdoor lighting.

Incommer:

40 Amps, 415V, 25KA(Isc), FP MCCB with thermal magnetic release having variable current setting

of 0.8 to 1.0 In.

1 set of phase indicating lamp with HRC fuses.

Timer

All incoming with 40A DIGITAL, 365 DAYS, 24 HRS. PROGRAMMABLE TIMER with suitable contactor.

Busbar:

100 AMP,25KA, 650 Volts, 3 phase 50 Hz FP Al. bus bars of suitable length - Current ratio shall be 1

sq mm = 0.8 A

Outgoings:

4 Nos. 20 Amps 415V, FP MCB phase indicating lamps.

9 Nos. 10 Amps 415V, DP MCB phase indicating lamps.

All MCBs are C-series type.

3 set 51,533.54 1,54,600.62

5 Campus / Outdoor Lighting Panel as above

Supply, Installation, testing & commissioning of standard light fittings and lighting accessories

including lamp and other accessories as required.The scope shall include, providing of all hardware

such as downrod, nuts,anchor fastners, bolts, screws, cleats, clamps, Lugs, PVC insulated wires /

cables (CROMPTON GREAVES / BAJAJ / PHILIPS)

5.1 Excavation in all sorts of soils including hard rock/ murrum for required depth and back filling.

Contractor's scope of work under this item shall include disposal of surplus earth and shoring,

shuttering and dewatering if required. Excavation shall be done as per directions of Engineer-in-

charge.

600 Rmt 190.89 1,14,534.00

5.2 Supplying and spreading fine sand for a thickness of 100 mm. and providing and laying bricks for

cable protection. on all the three sides.600 Rmt 124.23 74,538.00

5.3 Supply & fixing of 25mm. external dia rigid PVC conduit laid in floor/wall etc for laying of cable/GI

wire by cutting & making good for damages , inclusive of all tees, bends, elbows, reducers, bell

mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.

complete as per the direction of EIC.

600 M 46.46 27,876.00

ENGINEERING PROJECTS (INDIA) LIMITED

( A GOVT OF INDIA ENTERPRISE )

Name of the Work : Construction of 1st Phase (B+G+IV) of Administrative Building of New Town Kolkata Development Authority at Plot No. DG/13, Premises No. 04-3333,

NIT No. - DLI/CON/710/634 Dated 04.08.2018

BILL OF QUANTITIES

Page 15: VOLUME III - engineeringprojects.comengineeringprojects.com/Tender/UploadFiles/VOl-III.pdf · power cable directly in duct/hume pipe as per IS : 7098 ... Supply and Erecting of perforated

6 Supply, installation, testing and commissioning of 5.6 mtr above ground, seamless conical tapering

GI poles with single seamless conical tapering suitable length of GI bracket of approved shape &

suitable for mounting with 28W LED fixture & Solar Panel of approved make. The rates shall be

inclusive of necessary foundation (min. 450 x 450 x 750 mm, M:15) with anchor bolts coping with

baseplate, etc. complete. The pole shall have concealed type (flush door with proper strengthening

to the cutout of the door opening) junction box with loop in loop out connector (bakelite connector

of 15A) and MCB for fixture.

a) 40 mm diameter GI pipe with long bend for each cable entry .

b) Wiring up to the light fixture from the junction box using 3nos x 2.5 sq.mm. flexible copper wires

of specified make.

c) Excavation & back filling for erection of poles. Debris to be removed from the site to suitable

location instruction of the engineer incharge.

d) Earthing with GI earth spike, size 1822 length X 20 mm. dia directly driven in soil below ground

level & interconnection of spike with poles / looping box with 6 SWG GI wire (2 runs). GI protection

for earthing lead of suitable length (Av. 3 mtr. approx.) for pole earthing & looping box earthing.

40 set 1,06,050.00 42,42,000.00

7 Supply, installation, testing and commissioning of BOLLARD, GARDINA 2, 1x26W CFL(TU), HAVELLS

CAT NO. LHLC02126099 or approved equivalent, complete with base & log bolts,terminal box etc.

for garden & wiring through 3CX2.5 sqmm. copper armoured cable.

a) 25 mm diameter GI pipe with long bend for each cable entry .

b) Providing necessary foundation with 300mmX300mmX300mm. Deep 1:3:6 ratio cement

concrete complete as required.

c) Excavation & back filling for erection . Debris to be removed from the site to suitable location

instruction of the engineer incharge.

30 set 8,561.42 2,56,842.60

8 Supply, installation, testing and commissioning of JETA 6, 1X400W MH Set, HAVELLS CAT NO.

LHFY40140C99 with lamp or approved make, outdoor fittings as integral architectural flood

lightings, terminal box, etc. of building complete with all accessoies and necessary electrical wiring

through 3CX2.5 sqmm. copper armoured cable.

a) 25 mm diameter GI pipe for each cable entry .

b) Providing necessary foundation with 300mmX300mmX300mm. Deep 1:3:6 ratio cement

concrete complete as required.

c) Excavation & back filling for erection. Debris to be removed from the site to suitable location

instruction of the engineer incharge.

15 set 13,171.41 1,97,571.15

9 Supply, installation, testing and commissioning of Impact popular arrylic IP 65, 1X 70W SON,

Havells Cat No. LHRY28170D99, street light fixture, outdoor fitting, with 70 Watts Sodium Vapour

lamp complete with control gear, acrylic cover, terminal box, etc. and its wiring with 2CX2.5 sq.mm.

PVC insulated copper wire and 1.5 sq.mm. PVC insulated copper earth wire from control box

complete as required to be connected with Substation DB.(wiring for the same shall be paid in rmt)

4 Each 5,400.28 21,601.12

10 Garden spike and mini flood luminaires, 1 X 50W E-27 for garden use (Make : Bajaj) 20 Each 2,594.77 51,895.40

11 Supply, installation, testing and commissioning of Water body light philips cat no. EW Graze power

Wee narrow 2700K or equivalent model from approved makes as required.

The above installations shall be completed as per specifications and as required.20 Each 7,836.99 1,56,739.80

12 SITC of IP66 Water Tight Junction Box 139mm x 115mm x 70mm With necessary clamp for

mounting of the J.B. (All the cable / wire connections to the DB shall be with the Water tight IP 66

Polyamide Glands, open Holes should be sealed with the IP65 Grommets only ) J. B. Should be

provided with cable connectors to connect 1 nos. of 4.0 sq. mm. x 2 core cables + Earth wire & 6

nos. of 2.5 sq. mm x 2 core wires + Earthing wires.(Make of Hensel make cat.no. KD5065 +

Connectors + IP65 Glands + IP65 Grommets or equivalent) (wiring for the same shall be paid in

rmt) - fountain, ramp light, etc. from Campus lighting Panel (wiring for the same shall be paid in

rmt).

4 Each 1,055.45 4,221.80

54,70,262.29

Page 16: VOLUME III - engineeringprojects.comengineeringprojects.com/Tender/UploadFiles/VOl-III.pdf · power cable directly in duct/hume pipe as per IS : 7098 ... Supply and Erecting of perforated

Sl. Item Description Qnty Unit Rate (Rs.) Amount (Rs.)

1 Electrical Section -V ( Fire)

INSIDE PUMP HOUSE

Providing & fixing, testing and commissioning of electrically driven high pressure centrifugal fire

hydrant and sprinkler pump, suitable for automatic operation consisting of the following:

Horizontal, end suction centrifugal pump, suitable for operation on 415 volts ± 6%, 3 phase, 50 HZ

A.C supply. The installation shall be complete with flexible coupling and coupling guard as

required. Fire pump shall have C.I. casing, CS diffusers, bronze impeller (hard finished and

dynamically balanced) and S.S. (304) Shaft with mechanical seal, capable for delivering head to

ensure a minimum pressure of 3.5 Kg/Sqcm at the farthest or topmost hydrant / sprinkler. The

installation shall be complete with necessary pressure gauge with gun metal shut off cock on

delivery side.

Squirrel cage induction motor, TEFC type suitable for operation on 415 volts, 3 phase 50 HZ A.C

supply, for the above pump with synchronous speed of 2900 RPM, conforming to IP 55 protection

& class F insulation. The motor shall conform to IS 325-1978 (up to date) with flexible coupling

and coupling guard, complete as required.

Suitable cement concrete foundation with cement concrete plaster (design and drawing to be

provided by the Contractor while the foundation will be done by others) complete with anti-

vibration arrangement of cushy foot mountings.

The complete Pumps and Motor sets shall mounted on common MS base frame.

The rate includes interconnecting cables, foundations design & foundation bolts

Capacity : 2850 LPM.

Head : 80 M

2 Sets 2,35,000.00 4,70,000.00

2 Providing & fixing, testing and commissioning of Diesel Engine driven fire pump suitable for

automatic operation comprising of the following and conforming to BS 649/IS 10002 all

amended upto date.

Horizontal, split casing centrifugal pump, suitable for operation on 415 volts ± 6%, 3 phase, 50 HZ

A.C supply. The installation shall be complete with flexible coupling and coupling guard as

required. Fire pump shall have C.I. casing, CS diffusers, bronze impeller (hard finished and

dynamically balanced) and SS (304) shaft with mechanical seal, capable for delivering head to

ensure a minimum pressure of 3.5 Kg/Sqcm at the farthest or topmost hydrant / sprinkler. The

installation shall be complete with necessary pressure gauge with gun metal shut off cock on

delivery side.

Heat exchanger cooled (secondary cooling) diesel engine of speed 1500 RPM suitable for the

above pump with automatic starting mechanism and other accessories including fuel tank

(fabricated from 3mm MS sheet, painted with two coats of synthetic enamel paint over a coat of

primer) of capacity adequate to sustain pump operation for 8 hours continuous working. The tank

shall be fitted with Magnetic oil level indicator, MH with cover, drain valve, air vent including

structural supports (painted with approved shade), 2 Nos. x 12 volt battery, heat exchanger with

necessary piping connections & fittings, flexible coupling, coupling guard & exhaust pipe

connection complete as required.

The complete Pumps and Motor sets shall mounted on common MS base frame. Interlocking with

the main pump so that both electrical and diesel do not operate simultaneaously.

Suitable cement concrete foundation with plaster, (design and drawing to be provided by the

Contractor while the foundation will be done by others) complete with antivibration arrangement

of cushy foot mountings.

The rate includes interconnecting cables, foundations Design & foundation

1 Set 7,27,200.00 7,27,200.00

ENGINEERING PROJECTS (INDIA) LIMITED

( A GOVT OF INDIA ENTERPRISE )

Name of the Work : Construction of 1st Phase (B+G+IV) of Administrative Building of New Town Kolkata Development Authority at Plot No. DG/13, Premises No. 04-3333,

NIT No. - DLI/CON/710/634 Dated 04.08.2018

BILL OF QUANTITIES

Page 17: VOLUME III - engineeringprojects.comengineeringprojects.com/Tender/UploadFiles/VOl-III.pdf · power cable directly in duct/hume pipe as per IS : 7098 ... Supply and Erecting of perforated

Sl. Item Description Qnty Unit Rate (Rs.) Amount (Rs.)

3 bolts.

Capacity : 2850LPM.

Head : 80 M

Supply, installation, testing and commissioning of Jockey pump (pressurisation pump) of the

following duty:

Horizontal end suction Centrifugal pump, suitable for operation on 415 volts ± 6%, 3 phase, 50 HZ

A.C supply. The installation shall be complete with Flexible coupling and coupling guard, complete

as required. Jockey pump shall be of stainless steel construction.

Horizontal, end suction centrifugal pump, suitable for operation on 415 volts ± 6%, 3 phase, 50 HZ

A.C supply. The installation shall be complete with flexible coupling and coupling guard as

required. Fire pump shall have C.I. casing, CS diffusers, bronze impeller (hard finished and

dynamically balanced) and S.S. (304) Shaft with mechanical seal, capable for delivering head to

ensure a minimum pressure of 3.5 Kg/Sqcm at the farthest or topmost hydrant / sprinkler. The

installation shall be complete with necessary pressure gauge with gun metal shut off cock on

delivery side. (The pump should be tested for bench mark at factory and shall be gotten approved

by the Local fire Authority).

Squirrel cage induction motor TEFC type for operation on 415 V, 3 phase 50 HZ AC supply for the

above pump with a synchronous speed of 2900 R.P.M. with flexible coupling and coupling guard

etc. as required.

The complete Pumps and Motor sets shall mounted on common MS base frame.

Suitable cement concrete foundation with plaster, (design and drawing to be provided by the

Contractor while the foundation will be done by others) complete with Antivibration arrangement

of cushy foot mounting.

For pump defined above & of duty as follows :

Flow : 180 LPM,Head : 80M

1 Set 95,950.00 95,950.00

4 Providing & fixing MS Class ‘C’ diesel engine exhaust pipe (including all fittings, clamps, steel

support) of suitable dia for the engine. The pipe shall be provided with 12 mm thick supercera

ceramic fibre rope.

150 mm dia

36 RM 1,818.00 65,448.00

5 Providing & fixing dial type (150 mm) pressure gauge suitable for working pressure of 250 PSI. 5 Each 1,111.00 5,555.00

6 Providing & fixing testing and commissioning of adjustable pressure switches for

jockey pump/ electric pump along with control wiring up to main panel as required 8 Each 2,222.00 17,776.00

Control Panel for Fire Pumps.

Fabricating & supply, installing, testing and commissioning of compartmentalised common control

Panel for Electrical Motor driven pumps.

and diesel engine driven pump.

INCOMING.

1 nos.630 A TPN MCCB (25KA)

PVC Sleeves.

1 set RYB indicating lamps with individual HRC Control fuses.

1 No. 96 sq.mm 0-600 Amps. Ammeter with selector switch and suitable rated.

current transformers.

1 No. 0-500V 96 sqmm Voltmeter with selector Switch.

1 Nos 600 A, 4 POLE ATS (ASCO 300 Series) OVER LAPPING NEUTRAL.

OUTGOING

Feeder for Main Fire Pump - 2 Nos.

1 Nos 250 A TP MCCB.

DOL starter with TP Contractors and indicating lamps ON/OFF/TRIP push.

Buttons

2 Nos. Automanual Switch.

Feeder for Jockey Pump - 1Nos.

1 No.32 TP MCCB

DOL starter with TP contractors and indicating lamps with ON/OFF/Trip

push buttons.

2 No. 32 A. TP MCCB (Spare)

3 Nos Auto manual switch

1 set 1,86,850.00 1,86,850.00

7

Page 18: VOLUME III - engineeringprojects.comengineeringprojects.com/Tender/UploadFiles/VOl-III.pdf · power cable directly in duct/hume pipe as per IS : 7098 ... Supply and Erecting of perforated

Sl. Item Description Qnty Unit Rate (Rs.) Amount (Rs.)

DIESEL ENGINE PUMP (STAND BY OPERATION) - 1 No.

20 Amps DPMCB - 2 Nos

Battery charger with transformers with rectifier resistence DC ammeter, DC

voltmeter, Trickle/Booster/Off selector switch -2 nos

1 set of indicating lamps for the following :

Phase indication

Battery charger on

DC supply on

Control switch on

Engine fails to start

Pump on

Low oil pressure.

High water temperature.

Auto manual selector switch.

1 sets of push button stations for the following :

Engine start.

Engine stop

Engine hooter ACK.

Engine Fault reset.

Selector switches (Engine control, mode selector) - 1 No.

Auxilarys relays /contactors/timer for sequence

and stopping of the engine - 1 set

Hooter for Audio Alarm (Indusrial type) -1 set

All the components shall be housed in a common cubical made of 16 SWG MS Sheet with required

stiffners (if required) The Panel shall be powder coated of approved color both inside & outside.

The Panel shall be powder coated of approved colour both inside & outside. The Panel shall have

both bottom & top cable entry provisions and panel shall be mounted on Pedestal of 300 mm

height Also panel shall have sufficient (minimum 06 nos per pump set) NO/NC contacts for

extending the status of Fire Pumps to integrate with the Fire Alarm Panel

8 1100 V GRADE POWER / CONTROL CABLES

Supply, laying, testing & commissioning of FRLS, PVC outer sheathed, steel armoured,

aluminium/copper condoctor,1100 V grade power cables with glands etc. The cables shall be laid in

tray/hume pipe/in trenches/on walls/floor etc.as required. For cables laid outdoor the rate shall

include Earth excavation providing brick and sand protection ,refiliing and compacting the Earth.

The rate shall excludes tray & Hume Pipes. The minimum size of the cable shall mentioned below

8.1 3.5 C x 70 sq mm YFY for Main Pumps 35 Meter 757.50 26,512.50

8.2 4 C x 10 sq mm YFY for Jockey Pumps 20 Meter 242.40 4,848.00

8.3 12 C x 2.5 sq mm for Diesel Engines 20 Meter 459.55 9,191.00

8.4 2 C x 2.5 sqmm for instrumentation 55 Meter 191.90 10,554.50

9 G.I Earthing strips of 50 mm x 6 mm thick strip shall be run on floor/ceiling/walls etc from Fire

Pumps to MCC Panel30 Meter 85.85 2,575.50

10 Supply,installation,testing & commissioning of MS Pipes IS : 1239/3589 with painting, one coat of

primer with two coats of synthetic enamel paint of approved color/shade.(Above Ground Piping)

10.1 200 mm Nb (6.35 mm thick. IS-3589) 36 RM 2,020.00 72,720.00

10.2 150 mm Nb 24 RM 1,717.00 41,208.00

10.3 100 mm Nb 6 RM 1,111.00 6,666.00

10.4 50 mm Nb 18 RM 454.50 8,181.00

10.5 25 mm Nb 6 RM 277.75 1,666.50

11 Supply,installation,testing & commissioning of CI Gate Valve as per IS : 14846 (PN 10) and non

rising spindle type with flanges,

bolts, nuts, washers, gaskets, etc.

11.1 150 mm Nb 3 Each 11,110.00 33,330.00

11.2 100 mm Nb 1 Each 6,060.00 6,060.00

11.3 c) 50 mm Nb 2 Each 3,535.00 7,070.00

12 Supply, installation, testing & commissioning of CI Non Return Valve as per IS : 5312 (PN 16) swing

check type with required

flanges, nuts, bolts, gaskets etc.

12.1 150 mm Nb 4 Each 10,100.00 40,400.00

12.2 50 mm Nb 1 Each 3,535.00 3,535.00

12.3 40 mm Nb 4 Each 3,030.00 12,120.00

13 Supplying, Installation, testing & commissioning of Aluminium Di- Cast Butterfly valves (PN 16)

standard lever operated type with flanges,nuts & bolts, gaskets etc.

40 mm Nb

4 Each 2,828.00 11,312.00

14 Supplying, Installation, testing & commissioning Gun Metal screw type Ball Valve.

25 mm Nb14 Each 1,010.00 14,140.00

15 Supply,installation,testing & commissioning of CI Foot valve wuth suction strainer with companion

flanges,gaskts,nuts,bolts etc

15.1 200 mm Nb 3 Each 12,120.00 36,360.00

15.2 80 mm Nb 1 Each 5,050.00 5,050.00

1 set 1,86,850.00 1,86,850.00

7

Page 19: VOLUME III - engineeringprojects.comengineeringprojects.com/Tender/UploadFiles/VOl-III.pdf · power cable directly in duct/hume pipe as per IS : 7098 ... Supply and Erecting of perforated

Sl. Item Description Qnty Unit Rate (Rs.) Amount (Rs.)

16 Hydrant System

Supply,installation,testing & commissioning of MS Pipes IS : 1239 (medium grade) with painting,

one coat of primer with two coats of synthetic enamel paint of approved color/shade.( Above

Ground Piping )

16.1 150 mm Nb 448 RM 1,717.00 7,69,216.00

16.2 100 mm Nb 55 RM 1,111.00 61,105.00

16.3 80 mm Nb 100 RM 858.50 85,850.00

17Supply,installation,testing & commissioning of MS Pipes IS : 1239 (medium grade) being laid in

trenches/hume pipe support complete with necessary fitiings e.g bends,flanges etc and insulated

with Anticorrosive bitumen primer and wrapped with 3 mm thick Polymer corrosion resistant tape.

150 mm Nb

20 RM 2,020.00 40,400.00

18 Supply,installation,testing & commissioning of Hume pipe with jointing collars NP2 for laying of

under ground pipe.

300 mm dia

24 RM 2,424.00 58,176.00

19 Supplying, Installation, testing & commissioning of Aluminium Di- Cast Butterfly valves (PN 16)

standard lever operated type with flanges,nuts & bolts, gaskets etc.

150 mm Nb

4 Each 2,828.00 11,312.00

20 Supply,installation,testing & commissioning of CI Non Return Valve as per IS dual plate wafer type

with required flanges, nuts, bolts, gaskets etc.

150 mm Nb.

4 Each 1,313.00 5,252.00

21 Supply,installation,testing & commissioning of 25 mm Nb GM Air Release Valve on Hydrant and

Sprinkler riser

21.1 Providing & fixing dial type (150 mm) pressure gauge suitable for working pressure of 250 PSI on

top of Hydrant Riser2 Each 1,111.00 2,222.00

22 Supply,installation,testing & commissioning of Fire Hydrant eqiupments as follows:

22.1 SS Single head Hydrant Valve as per Is 5290 with 63 mm dia instantaneous couplings & 80mm dia

flanged inlet,Blank caps,chain.

For External/Yard Hydrant System

6 Each 5,454.00 32,724.00

22.2 SS Single head Landing Valve as per Is 5290 with 63 mm dia instantaneous couplings & 80mm dia

flanged inlet,Blank caps,chain.

For Internal Hydrant System

15 Each 5,454.00 81,810.00

22.3 One length of 15 m long,63 mm dia RRL Hose with SS instantaneous couplings and copper binding

for internal Hydrant.15 Each 4,545.00 68,175.00

22.4 Two length of 15 m long,63 mm dia CP Hose with SS instantaneous couplings and copper binding

for external Hydrant.12 Each 4,040.00 48,480.00

22.5 SS short Branch Pipe with 16 mm nozzle. 21 Each 1,818.00 38,178.00

22.6 CRCA Hose cabinet accompanied 1 no RRL Hose,Branch Pipe for Internal Hydrant. 15 Each 2,020.00 30,300.00

22.7 CRCA Hose cabinet accompanied 2 nos. CP Hose,Branch Pipe for External Hydrant. 6 Each 1,616.00 9,696.00

22.8 Fire First Aid Hose Reel drum with 20mm Nb Thermo Plast Hose of 30 mtr in lenghth and dual type

(jet+spray) nozzle complete.15 Each 5,858.00 87,870.00

22.9 4 way Fire Brigade Inlet connection, 63 mm dia in built dia SS non return valve 1 Each 5,050.00 5,050.00

22.10 4 way Fire Water Reservoir Inlet connection, 63 mm dia in built dia SS non return valve 1 Each 5,050.00 5,050.00

23 Fire Water Sprinkler System

Supply, installation, testing & commissioning of MS Pipes IS : 1239/3589 with painting, one

coat of primer with two coats of synthetic enamel paint of approved color/shade.(Above Ground

Piping)

23.1 150 mm Nb 160 RM 1,717.00 2,74,720.00

23.2 100 mm Nb 119 RM 1,111.00 1,32,209.00

23.3 80 mm Nb 398 RM 858.50 3,41,683.00

23.4 65 mm Nb 195 RM 505.00 98,475.00

23.5 50 mm Nb 91 RM 454.50 41,359.50

23.6 40 mm Nb 391 RM 479.75 1,87,582.25

23.7 32 mm Nb 484 RM 404.00 1,95,536.00

23.8 25 mm Nb 2100 RM 277.75 5,83,275.00

24 Supplying, Installation, testing & commissioning of Aluminium Di- Cast Butterfly valves (PN 16)

standard lever operated type with flanges,nuts & bolts, gaskets etc.

100 mm Nb

10 Each 3,636.00 36,360.00

25 Supply, installation, testing & commissioning of CI Non Return Valve as per IS dual plate wafer type

with required flanges, nuts, bolts, gaskets etc.

100 mm Nb

10 Each 5,353.00 53,530.00

26 Supplying, Installation, testing & commissioning Gun Metal screw type Ball Valve.

25 mm Nb40 Each 1,010.00 40,400.00

27 Supplying, Installation, testing & commissioning Standard response quartzoid bulb type sprinkler

with 15 mm screwed end connection of 68 deg. C temparature rating and Sprinkler shall must be

UL listed.

27.1 Upright Sprinkler 442 Each 202.00 89,284.00

27.2 Pendent Sprinkler 631 Each 202.00 1,27,462.00

27.3 Sidewall sprinker for Ramp area 225 Each 222.20 49,995.00

28 Supplying, Installation, testing & commissioning Stainless steel corrogated flexible pipe (hose) for

dropping sprinklers below

false ceiling,pipe shall be UL listed

214 Each 1,313.00 2,80,982.00

Page 20: VOLUME III - engineeringprojects.comengineeringprojects.com/Tender/UploadFiles/VOl-III.pdf · power cable directly in duct/hume pipe as per IS : 7098 ... Supply and Erecting of perforated

Sl. Item Description Qnty Unit Rate (Rs.) Amount (Rs.)

29 Supplying, Installation, testing & commissioning of Sprinkler control valve ( ICV ) with motor gong

bell and trims as required.

150 mm Nb

3 Each 45,450.00 1,36,350.00

30 Supplying, Installation, testing & commissioning of Water Flow switch. 11 Each 2,474.50 27,219.50

31 Providing & fixing dial type (150 mm) pressure gauge suitable for working pressure of 250 PSI on

top of Sprinkler Riser2 Each 1,111.00 2,222.00

32 Steel structure & supports 1 Lot 35,350.00 35,350.00

33Fire Extinguishers and Fire Check Door

Supply, installaing and commissioning of Portable Fire Extinguishers of following type & capacity

34 Carbon Di-oxide type Fire Extinguishers

34.1 2.0kg capacity 15 Each 3,333.00 49,995.00

34.2 4.5 kg capacity 20 Each 5,050.00 1,01,000.00

35 Dry chemical type Fire Extinguishers

35.1 5.0 Kg capacity 70 Each 1,313.00 91,910.00

35.2 10.0 kg capacity 10 Each 1,616.00 16,160.00

36 WCO2 type Fire Extinguishers

36.1 9.0 ltrs capacity 40 Each 1,414.00 56,560.00

36.2 Mechanical Foam

36.3 9.0 ltrs capacity 8 Each 1,616.00 12,928.00

36.4 Fire Buckets round bottom type enamel painted white inside, red outside with lid and mounting

Bracket.8 Each 454.50 3,636.00

36.5 2 hours Rated Wooden Fire Check Door (Frame & Shutter) with paint finish.( Frame & Shutter )

with paint finish. ( Two nos )200.00 sqm 6,767.00 13,53,400.00

36.6 Moduler type Clean Agent Fire Extinguishers, Capacity 4.0 Kg capacity 39.00 Each 17,170.00 6,69,630.00

36.7 Moduler type ABC Fire Extinguishers, Capacity 5.0 Kg capacity 5.00 Each 7,070.00 35,350.00

37 SIGNAGES

37.1 Photoluminescence signages " FIRE EXIT " 40 Each 378.75 15,150.00

37.2 Floor identification signages 20 Each 151.50 3,030.00

37.3 Electronic signages with emergency battery back up for 12 hours 16 Each 2,020.00 32,320.00

37.4 Fire Notice 8 Each 505.00 4,040.00

38 Fire Alarm and Detection System

Providing & Fixing, testing & commissioning of Addressable Pull type Manual Call point with all

necessary fittings and consumables

56 Each 3,181.50 1,78,164.00

39 Providing & Fixing, testing & commissioning of Addressable Hooter cum Strobe/ Flasher with all

necessary fittings and consumables40 Each 3,333.00 1,33,320.00

40 Providing & Fixing, testing & commissioning of Addressable Photo Electric Smoke Detector with all

necessary fittings and consumables449 Each 2,979.50 13,37,795.50

41 Providing & Fixing, testing & commissioning of Addressable Heat Detector with all necessary

fittings and consumables12 Each 2,929.00 35,148.00

42 Providing & Fixing, testing & commissioning of Addressable Fault Isolator Modules with all

necessary fittings and consumables19 Each 2,525.00 47,975.00

43 Providing & Fixing, testing & commissioning of Addressable Monitor Modules with all necessary

fittings and consumables10 Each 2,828.00 28,280.00

44 Providing & Fixing, testing & commissioning of Addressable Duct Sensor Detector with all necessary

fittings and consumables425 Each 6,565.00 27,90,125.00

45 Providing & Fixing, testing & commissioning of Addressable Control Modules with all necessary

fittings and consumables225 Each 3,333.00 7,49,925.00

46 Providing & Fixing, testing & commissioning of Response Indicator 170 Each 85.85 14,594.50

47 Providing & Fixing, testing & commissioning of 6W wall/ceiling mounted loud speaker 300 Each 707.00 2,12,100.00

48 Providing & Fixing, testing & commissioning of 250 watt RMS output solid state Amplifier with

Microphone1 Set 25,250.00 25,250.00

49 Providing & Fixing, testing & commissioning of Microprocessor based Intelligent Fire Alarm Panel

With battery and battery chargers,The FACP shall have provision of Loop expansion and shall be

networkable type. Provision for interfacing with other systems such as SCADA / IBMS with all

required hardware and software.

1 Set 2,77,750.00 2,77,750.00

50 Providing & Fixing, laying and termination of Power and Control cable .

PVC sheathed and insulated copper Armour Cable 2 core x 1.5 sq mm3000 RM 146.45 4,39,350.00