vrf catalog small 2020 - iapl group
TRANSCRIPT
2/8, (IAPL House) West Patel Nagar, New Delhi - 110008Tel.: 011-47230000-99For Customer Assistance: Toll Free No.: 1800 102 0055Email: [email protected], Website: www.iaplgroup.com
Sales, Service Office in India
BIWAJIMA PLANTMitsubishi Heavy Industries, Ltd.
Air-conditioning & Refrigeration Systems Headquarters
MITSUBISHI HEAVY INDUSTRIES-
MAHAJAK AIR CONDITIONERS CO., LTD.
Mitsubishi Heavy
Industries-Haier (Quingdao)
Air-conditioners Co.,Ltd.
MITSUBISHI HEAVY INDUSTRIES-
MAHAJAK AIR CONDITIONERS CO.,LTD.
ISO 14001
Certificate 04104 1998 0813 E5
Mitsubishi Heavy
Industries-Haier (Quingdao)
Air-conditioners Co.,Ltd.
BIWAJIMA PLANTMitsubishi Heavy Industries, Ltd.
Air-conditioning & Refrigeration Systems Headquarters
Mitsubishi Heavy Industries- Mahajak Air Conditioners Co.Ltd. Lat krabang Industries Estate, Phase 3, 200 Moo 4, ChalongkrungRoad, Lamplatiew, Lat krabang, Bangkok Thailand 10520
Sales, Service & Marketing Headquarter (India)
: :
Before starting use
Safety Precautions
Heating Performance Refrigerant Leakage
Indication of sound values Use in snowy areas
•Snow prevention
•Snow Piling
Automatic defrosting device
Servicing the air- conditioner
Use in oil atmosphere
Use in acidic or alkaline atmosphere
Use in places with high ceilings
Air- Conditioner usage target Installation
Before use
Usage place
IAPL GROUP
16-5,Konan 2-chome, Minato-ku, Tokyo, 108-8215 Japan
(Wholly-owned subsidiary of MITSUBISHI HEAVY INDUSTRIES, LTD.)
http://www.mhi-mth.co.jp/en/
HO SALES: DELHI + NCR: MUMBAI / MAHARASHTRA:9953453020 / 8800190709, 8826390505 9899143596, 8879599905,
8939991876, 9946448081, 8697744670, 7069072011,TAMIL NADU : KERALA: WEST BENGAL : GUJARAT & MADHYA PRADESH:
9636225333, 8826392387, 8377901197, 8826392387,RAJASTHAN: UTTAR PRADESH / UTTARAKHAND: PUNJAB: HARYANA:
8377901197, 9885651712,JAMMU & KASHMIR: KARNATAKA / ANDHRA PRADESH / TELANGANA:
8826396161, 8826392333, 8800190708, 8826396161.SERVICE: PROJECT:
R41R410AR410A
Design in Japan,
Made forIndia
New
PERFORMANCE
HO TOH
High PerformanceAir-Conditioning
Co
un
try
of O
rigin
:Th
aila
nd
NEW
Series
2
Design in Japan,
Made forIndia
The origin of MHI can be all the way back to 1884. In that year, YataroIwasaki, the founder of Mitsubishi took a lease of Government- ownedNagasaki Shipyard. He named it Nagasaki Shipyard & Machinery Works, andstarted the shipbuilding business on a full scale. This shipbuilding business waslater turned into Mitsubishi Shipbuilding Co.,Ltd., and was again launched asMitsubishi Heavy- Industries, Ltd., in 1934, establishing its position as thelargest private firm in Japan. Mitsubishi Heavy Industries is Japan's largestshipbuilding and machinery maker and is a mammoth company involved inan array of Industrial concerns. With nearly 150 subsidiaries, Mitsubishi HeavyIndustries Ltd. (MHI) operates in 11 key sectors. Shipbuilding, Air-Conditioning and Refrigeration Systems, Nuclear Energy Systems, GeneralMachinery and Components, Paper and Printing Machinery, SteelStructures and Construction, Machinery and Plants, Machine Tools, PowerSystems, Aerospace System, Industrial Machinery, Infrastructure projectsand produces everything from Airconditioners & System (Room AC, Semi-Commercial, Commercial, VRF, Centrifugal & Absorption Chillers), Jetengines, Passenger aircraft, Wind- Mills, Cruise ships and Oil tankers, toConstruction Machinery, Newsprint Machines, Turbines, Nuclear PowerPlants, Thermal Power Plants airplanes, gasoline engines, and gear cuttingmachines.
Mitsubishi Heavy Industries Japan
135 years of technological innovations
Yataro Iwasaki, founder of Mitsubishi
1884: the Nagasaki shipyards at the timethe company was founded
Mitsubishi Heavy Industries- IAPL Group is a Strategic
alliance of Mitsubishi Heavy Industries - MahajakAirconditioners Co. Ltd. & IAPL Group, for sales,marketing & service of Mitsubishi Heavy Ind. HeavyDuty Room, Commercial Airconditioners & VRFSystems in India.
IAPL Group with its nationwide network has supporteda wide array of projects including residential & largecommercial establishment, Offices, Businessestabl i shments, Hotels , Hospitals , Schools ,Commercial Complexes, Industries, etc. We haveparticipated in projects for large Air ConditioningSystems requiring SYSTEM INTEGRATION of importedair conditioning equipment as per the internationalstandards lay down by our principal- M/s. MitsubishiHeavy Industries Ltd. We ensure much superior qualityof workmanship with advanced engineering skills. Wehave full- fl edged team of qualified engineers andtechnical staff in the air- conditioning divisions to meetall kind of requirements. IAPL has consistently providedChannel Partners with timely and high value service,competitively priced products without sacrificingquality.
IAPL has its branch offices and Authorized GenuineSpares & Service Center Network at all major cities ofIndia.
Air-Conditioning
State of an Art
3
Established Since - 1884
4 5
Product lineup has been extended up to 60HP
with combination of 3 outdoor units.
Product Line Up
4HP 5HP 6HP
FDC140KXEN6
FDC140KXES6
FDC155KXEN6
FDC155KXES6
FDC112KXEN6
FDC112KXES6
8HP* 10HP*
26HP
FDC735KXZE1
28HP
FDC800KXZE1
30HP
FDC850KXZE1
32HP
FDC900KXZE1
12+14 14+14 14+16 16+16
FDC335KXZE1FDC400KXZE1
FDC400KXZE1FDC400KXZE1
FDC400KXZE1FDC450KXZE1
FDC450KXZE1FDC450KXZE1
36HP
FDC1000KXZE1
38HP
FDC1060KXZE1
40HP
FDC1120KXZE1
18+18 18+20 20+20
FDC500KXZE1FDC500KXZE1
FDC500KXZE1FDC560KXZE1
FDC560KXZE1FDC560KXZE1
1-phase 220-240V
3-phase 380-415V
42HP
FDC1200KXZE1
44HP
FDC1250KXZE1
46HP
FDC1300KXZE1
48HP
FDC1350KXZE1
14+14+14 14+14+16 14+16+16 16+16+16
FDC400KXZE1FDC400KXZE1FDC400KXZE1
FDC400KXZE1FDC400KXZE1FDC450KXZE1
FDC400KXZE1FDC450KXZE1FDC450KXZE1
FDC450KXZE1FDC450KXZE1FDC450KXZE1
54HP
FDC1500KXZE1
56HP
FDC1560KXZE1
58HP
FDC1620KXZE1
60HP
FDC1680KXZE1
18+18+18 18+18+20 18+20+20 20+20+20
FDC500KXZE1FDC500KXZE1FDC500KXZE1
FDC500KXZE1FDC500KXZE1FDC560KXZE1
FDC500KXZE1FDC560KXZE1FDC560KXZE1
FDC560KXZE1FDC560KXZE1FDC560KXZE1
model
FDC224KXZPE1 FDC280KXZPE1
*Tropical Usage mode, best suited for Indian conditions.
12HP
FDC335KXZE1 FDC400KXZE1 FDC450KXZE1
FDC500KXZE1 FDC560KXZE1
Standard Model
18HP 20HP
NEW
Lite
KXZE1
Improved Hybrid Series
6
Design in Japan,
Made forIndia
44HP
FDC1230KXE6
22+22
FDC615KXE6FDC615KXE6
46HP
FDC1295KXE6
22+24
FDC615KXE6FDC680KXE6
48HP
FDC1360KXE6
24+24
FDC680KXE6FDC680KXE6
22HP
FDC615KXZE1
24HP
FDC670KXZE1
12+10 12+12
FDC335KXZE1FDC280KXZE1
FDC335KXZE1FDC335KXZE1
Wide variety of 17 types 93 models
<Indoor units>
Indoor units lineup
22
Capacity
Model Code : kWType
28 36 45 56 71 90 112 140 160 224 280
0.8 1HP HP 1.25 HP 1.6HP
250Air Flow M /h3
Type 350 500 650 800 850 1000 1300 1800
4way FDT
4way Compact
(600 x 600)FDTC
2way FDTW
1way Compact
1way
Wall Mounted FDK
FDE
FDFW
Low Static
Pressure
(thin)FDUT
15
0.5HP
FDUH
High
Static Pressure FDU
Low/Middle
Static Pressure FDUM
with casing
2way
FDFL
without casing FDFU
SAF
FDTS
Ceiling
Cassette
Floor
Standing
Duct
Connected
Fresh Air DX Assembly SAF-DX
OA Processing unit FDU-F
Fresh Air Ventilation and
Heat Exchange unit
NEWNEW
NEWNEWNEWNEW
150
2 HP 2.5HP 3.2HP 4 HP 5 HP 6 HP 8 HP 10 HP
NEW
FDTQ
Compact &
Flexible
Ceiling Suspended
7
NEW
NEW
22HP 24HP
FDC615KXE6 FDC680KXE6
14HP
A range of 17 types of exposed or concealed
indoor units available in a wide range of
capacities (total 93 indoor models). The best
solution of indoor units for all applications is
available from our full lineup.
NEW NEW
NEW
¤ Power supply for outdoor and indoor units are 3 phase 380-415V, 50Hz and 1 phase 220-240V, 50Hz respectively. ¤ Power supply for outdoor and indoor units are 3 phase 380-415V, 50Hz and 1 phase 220-240V, 50Hz respectively.
NEW
NEW
FDU-F series are not connectable toMicro model (4~6HP), KXZ Lite.
16HP
8 9
Energy Saving Technology
NEWNEWTop Class Energy Efficiency
EER (Energy Efficiency Ratio)
ESEER (European Seasonal Energy
Efficiency Ratio)
KX Series has achieved superior EER which far
surpasses competitors's EER at all range.
On average, KX series has 13 % higher EER
than competitor
KX Series also surpasses competitor’s ESEER at all range.
On average, KX series has 9% higher EER than
competitor
4 5 6 8 10 12 14 16 18 20 22 24
3.0
3.2
3.4
3.6
3.8
4.0
4.2
4.4
4.6
4.8
5.0
5.2
EER
HP4 5 6 8 10 12 14 16 18 20 22 24
EER
HP
3.6
3.8
4.0
4.2
4.4
4.6
4.8
5.0
5.2
5.4
5.6
5.8
6.0
6.2
6.4
6.6
NEWNEW VTCC : Variable Temperature and Capacity Control (KXZ)
Normal operation (in the cooling mode) Energy saving operation (in the cooling mode)
Off Off Off
Room temperature
Set temperature
Compressor
Target low pressure
Constant level
Room temperature
Set temperature
Compressor
Target low pressure
Check temp difference
Energy Saving : Max 34%
Target low pressure was set at the constant level.
When room temperature got closer to set
temperature, the compressor shifted operation
and repeated on-off operation continuously
Checking the difference between room and set
temperatures, the system adjusts compressor
speed and target low pressure effectively.
Meeting customer's requirement, manual
adjustment is available.
(Need to set 7-segment or external input)
Oil level control capability
Our proprietary technology of adjusting oil level for
combination of two or three outdoor units has
realized leveled operation rate, keeping performance
of the units and ensuring long life of the System
Oil-equalizing pipe
Improved Heat-exchanger
With piping layout rearranged from header
to heat exchanger, refrigerant distribution
flow has improved and maximum energy
efficiency has been achieved. Heat
exchanger has improved refrigerant
distribution and increased effectiveness.
Furthermore due to expansion of effective
heat transfer area in heat exchanger,
energy efficiency has increased.
Strengthened resistance against frostResistance against frost has been strengthened by achieving improved heat-exchanger.
[Previous] [KXZ]
Header Distributor
Vector control Vector Control
Po
we
r cu
rren
t
Operation period
New applied Vector control has a high efficiency
and many new advanced features.
• Smooth operation from low speed to high speed
• Smooth Sine Voltage Wave form are attained
• Energy efficiency is further improved in low speed range
Long-chorded 3 propeller fan
with serration
DC Fan Motor
Fan blade design adapted from MHI’s aerospace
division - with serrated edges that deliver increased
air volume with less power input.
Serration
Employment of DC fan motor has enabled to
realize an excellent efficiency of approximate
60% higher then previous models.
Rotor (Squirrel Cage made of conductor)
Stator (coil) Rotor (made of permanent magnet)
Stator (coil)
1110
NEWNEW3D Scroll Compressor that achieves high efficiency with low noise,
smaller size & lighter weight
For the purpose of meeting the demand for further efficiency improvement and large capacity, MHI
developed the three-dimensional scroll compressors (3D scroll) for commercial air-conditioner. By realizing
three-dimensional compression which is impossible for the conventional scroll, 5.5% improvement of efficiency,
35% smaller size and 26% lighter weight compared with the conventional compressor were archived, so that
substantial energy-saving effect and improvement of unit-mounting capacity are obtained.
3D scroll compressor
Discharge pipe
Fixed scroll
(3D scroll)
Orbiting scroll
(3D scroll)
Suction pipe
Motor
Crank shaft
Refrigerant flow
("3D scroll" is a registered trademark of MHI.)
Sectional views of conventional scroll and 3D scroll
Conventional scroll
Constant
wrap height
Outer wrap
height: Large
Orbiting scroll Orbiting scroll Inner wrap
height: Small
3D scroll
Two-dimensional compression Three-dimensional compression
Fixed scroll Fixed scroll
Concentrated winding motor achieves"High Output" and "Total Efficiency
Improvement"
The newly designed high performance CPU enables
high precision optimization for compressor speed,
which leads to concentrated winding motor use.
Our product achieves high output and better energy
saving effects and in particular improves seasonal
efficiency rating. Compressor Speed
Ou
tpu
t
Total Eciency
Conventional Distributed
Winding Motor
New Concentrated
Winding Motor
Improved SeasonalEfficiency rating
Applied for KXZE1:10/12/17/18/20HP, KXZXE1:8HP & KXZ Lite:8/10HP
NEWNEW Wider Range of Operation (KXZ, KXZ Lite)
KXZ, KXZ Lite series permits an extensible
system design considering a heating
range operation under a low
temperature condition down to -22°C
and a cooling range operation up to
55°C.
+15.5ºC-22ºC
+55ºC-15ºC
50403020100-10-20
Cooling
High Efficiency & Compact Design
High efficiency and compact design are realized byapplying various advanced components
Multiport compressor that achieves
high efficiency (KXZ, KXZ Lite)
The new multiport discharge area in the
compressor has optimized pressure
control with better balancing.
By optimizing
pressure adjustment
in decompression,
the compressor
realizes higher
efficiency.
Multi-discharge port
8 ~ 60HP (KXZ)
Efficient Heat Exchanger
DC Fan Motor
Tetrahedral structure of
Heat Exchanger
Double tube
New Inverter ControlImproved ScrollCompressor
NEWNEW
Discharge port
Design Flexibility
Long Pipe Length 10~60HP(KXZ)
Piping length has extended max height difference between indoor units up to 18m and enables us to put indoorunits on extra three floors. The furthest indoor unit: 160m or total length: 1000m contributes to system design flexibility.
Outdoor unit
Height difference
50m 70m(outdoor unit above)
40m(outdoor unit below)
Max height
difference
between
indoor units:
18m
Indoor unit
Indoor unit
Indoor unit
Max: 0.4m
Max: 10m (oil equalizing pipe)
Max: 5mTo the
first branch:
max 130m
From the first branch
to the furthest
indoor unit: 90m
Total length:1000m
*1
*2
Furthest
indoor unit:
160m
Blue FinDue to application of blue coated fins for the heat
exchanger of new outdoor unit, corrosion resistance
has been improved compared to current models.
BlueFin
BlueFin
The difference between the longest andthe shortest indoor unit piping from the firstbranch must be within 40m. (MAX85m)
In case of height difference up to 70m,please contact your dealer. Heightdifference up to 100m is possible withHigh Head series. Please refer to page 56.
*1
*2
12
Wired remote control (option)
Control Systems<Individual control>
Remote Control line upindoor unit remote control
wired all models
RCH-E3
RC-EX3A
RC-E5
indoor unit remote control
wireless RCN-TC-5AW-E2RCN-TW-E2
RCN-T-5AW-E2FDTC
FDTW
FDT
indoor unit remote control
RCN-K-E2RCN-K71-E2
RCN-TS-E2
FDK22~56FDK71
FDTS
indoor unit remote control
RCN-FW-E2RCN-KIT4-E2
RCN-E-E3
FDFWothers∗
FDE
∗FDTQ, FDU, FDUM, FDUT, FDUH, FDU-F
Easy touch and Easy view with full dot Liquid Crystal display
Operation mode setting screen
The desired operation mode can
be selected by simply tapping
this button.
Setting temperature screen
User friendly•LCD panel with light tap operation
introduced as the industry's first
•Simple interface with only three buttons
•Big LCD with 3.8 inch full dot display
Easy view
•Back light function
•Multi language display (12 languages)
Operation mode
Cooling
Dry
Auto
Fan
Heating
The highest capacity operation (Max 15 minutes)
•Increasing compressor speed
•Increasing air flow volume
High power operation•Changes set temperature.
At 28ºC in cooling mode and 22ºC in heating mode, 25ºC in auto mode.
•Operation correction by outdoor temperature
Energy-saving operation
You can select the temperature as
desired by tapping button.
RC-EX3A
Upto 16 Units AUTO Restart
Simple remote control (option)
RCH-E3 (wired)
For wireless control simply insert the infra-red receiver kit on a corner of the panel
Wireless remote control (option)
Thermistor (option)
SC-THB-E3
8m
*The wireless remote control is not applicable to the Individual flap control system.
NEW
13C
en
tral C
on
tro
l S
C-S
L2N
A-E
Ca
pa
ble
of
con
tro
l an
d m
on
itorin
g u
p t
o 6
4
ind
oo
r u
nits
.All
op
era
tion
al f
un
ctio
ns,
plu
s
en
ab
le/d
isa
ble
co
nn
ect
ed
re
mo
te c
on
tro
l.
Ce
ntr
al C
on
tro
l SC
-SL
1N
-E
Ce
ntr
al C
on
tro
l
SC
-SL
4-A
E/B
E
Mo
niti
rin
g P
C
(We
b B
row
ser)
Bu
ildin
g M
an
ag
em
en
t sy
ste
m
Ho
st c
om
pu
ter
Cen
tral co
ntr
ol
SC
-SL
4-A
,-B
We
b g
ate
wa
y &
BA
Cn
et
ga
tew
ay
SU
PE
RL
INK
E B
OA
RD
(S
C-A
DN
A-E
)
Co
nn
ect
ed
to
th
e t
erm
ina
ls f
or
Su
pe
rlin
k si
ng
le li
ne
s2
SL
E b
oa
rd
OF
FS
W3
SW
1
LED2
Run
Abnormal
LED3
SW
2
ON
A B X Y
X YA B
Blu
e
Blu
e
Bla
ck
White
Ma
ste
r/S
ub
ad
dre
ss
Ne
two
rk a
dd
ress
se
ttin
g s
witc
he
s
[00
0]-
(12
7)
Co
nn
ect
ed
to
th
e r
em
ote
co
ntr
ol t
erm
ina
ls (
no
po
larity
) (t
he
len
gth
sh
ou
ld b
e 6
00
m o
r sh
ort
er)
20
0 m
or
sho
rte
r3
00
m o
r sh
ort
er
40
0 m
or
sho
rte
r
60
0 m
or
sho
rte
r
0.5
mm
x 2
co
res
2
This
board
is u
sed w
hen c
onduct
ing c
ontr
ol o
f th
e s
ingle
pack
age (
wired r
em
ote
contr
ol u
nit)
1-t
ype s
eries
usi
ng a
netw
ork
optio
n.
SC
-WB
GW
256
Lo
nw
ork
s g
ate
way
SC
-LG
WN
B
MV
VS
0.7
5 -
1.2
5m
m
0.7
5 m
mx
2 c
ore
s2
1.2
5 m
mx
2 c
ore
s2
2.0
mm
x 2
co
res
2
3-c
ore
ca
ble
fo
r
con
ne
ctin
g in
do
or
an
d o
utd
oo
r u
nits
Ind
ivid
ua
l On
/Off C
on
tro
l
Mu
lti-K
X6
/KX
Z in
do
or
un
its
Mu
lti-K
X6
/KX
Z in
do
or
un
its
Mu
lti-K
X6
/KX
Z in
do
or
un
its
with
ind
ivid
ua
l ro
om
co
ntr
ol
3-c
ore
+ e
art
h c
ab
le
for
con
ne
ctin
g in
do
or
an
d o
utd
oo
r u
nits
3-c
ore
+ e
art
h c
ab
le
RA
Cse
ries
for
con
ne
ctin
g in
do
or
an
d o
utd
oo
r u
nits
SC
-AD
NA
-ES
C-A
DN
A-E
SC
-AD
NA
-E3-c
ore
ca
ble
fo
r
con
ne
ctin
g in
do
or
an
d o
utd
oo
r u
nits
Wire
less
rem
ote
con
tro
l
SC
-AD
NA
-E
Mu
lti-K
X6
ou
tdo
or
un
its
"Mic
ro m
od
el"
KX
Z O
utdo
or u
nits
KX
Z tw
ined
Out
door
uni
ts
SC
-GIF
N-E
Lig
htin
gF
an
SC-B
IKN
is n
ec
ess
ary
to
co
nn
ec
t to
wire
d r
em
ote
co
ntr
olle
r.
Run / Stop
Considering specialized usage in hotel rooms, control buttons are limitedonly to minimum required functions such as ON/OFF, mode, temperaturesetting and fan speed. It is really simple and easy to use.
It can control upto 16 unitsindividually, with pressingthe AIR CON No. button.
This function allows starting the air conditionerautomatically when power supply is restored afterpower failure or by turning on the power switch.
*RCH-E3 is not applicable to the Individual flop control system.*When RCH-E3 is used, the fan speed setting can only be set to 3 speed settings (Hi-Me-Lo).
In case sensor in the indoor units or the
remote control sensor can not sense
the room temperature correctly,
or individual remote control in each
room is not required but only sensor is
required (as when center control
system is in place),
install SC-THB-E3
at proper place
in the rooms. <SU
PER
LIN
K -
Co
ntr
ol Sy
ste
m>
Mitsu
bis
hi
He
avy
Ind
ust
rie
sTh
erm
al
Syst
em
sh
as
no
wc
om
bin
ed
sim
plic
ity
of
inst
alla
tio
nw
ith
ou
rh
igh
lyso
ph
istic
ate
dSu
pe
rlin
k-
co
ntr
ol
syst
em
,to
off
er
bu
ildin
go
wn
ers
an
do
cc
up
iers
a c
om
pre
he
nsi
ve
co
ntr
ol a
nd
ma
na
ge
me
nt
syst
em
, w
hile
pro
vid
ing
co
mp
lete
co
mm
issi
on
ing
an
dse
rvic
e m
ain
ten
an
ce
ass
ista
nc
efo
r in
sta
llers
an
dse
rvic
ee
ng
ine
ers
.Th
eSu
pe
rlin
k-
ne
two
rku
tilis
es
two
wire
,n
on
-po
lar
ca
ble
-fo
rfu
rth
er
de
tails
of
wirin
g.
Su
pe
rlin
k-
isa
na
dva
nc
ed
hig
hsp
ee
dd
ata
tra
nsm
issi
on
syst
em
tha
tc
an
co
nn
ec
tu
pto
128
ind
oo
ru
nits
an
d32
ou
tdo
or
un
its
as
an
etw
ork
.M
itsu
bis
hiH
ea
vy
Ind
ust
rie
sTh
erm
alSyst
em
so
ffe
rsa
wid
era
ng
eo
fc
on
tro
lo
ptio
ns
for
the
Su
pe
rlin
k-
ne
two
rkto
suit
an
ya
pp
lica
tio
nla
rge
or
sma
ll,a
sw
ell
as
co
nn
ec
tio
nto
ne
wo
re
xist
ing
bu
ildin
gm
an
ag
em
en
tsy
ste
ms.
Ind
ivid
ua
lM
itsu
bis
hiH
ea
vy
Ind
ust
rie
sTh
erm
al S
yst
em
s sp
lit s
yst
em
s c
an
als
o b
e in
teg
rate
do
nto
th
eSu
pe
rlin
k-
ne
two
rku
sin
gSC
-AD
NA
-E.
RCN-T-5AW-E2 RCN-K-E2,RCN-K71-E2
RCN-E-E3RCN-TW-E2 RCN-TS-E2 RCN-FW-E2
RCN-KIT4-E2
RCN-TC-5AW-E2
SL1N-E
SW1
SW2
SW3
51X
1 2 3 4 5 6 7 8 A B
52 52R
one’s place
hundred’splace
ten’s placePrinted board
Address setting switch
Net work communication line
Set address number will
be the address for
SC-SL1N-E,
SC-SL2NA-E,
SC-SL4-AE/BE
To A & B terminal block on
SC-SL1N- E,
SC-SL2NA -E,
SC-SL4- AE/BE
Terminal block
Net work
Start-Stop command output
AC220-240V
Anomalous signal input
Operation signal input
14 15
Control Monitoring Scheduling Administration/Service
Run/Stop / Home leave Operating state Yearly schedule Block definition, Floor layout
Mode (cool/heat/fan/dry/Auto) Mode Today's schedule Group definition
Set temperature Set temperature Detailed daily schedule
Season setting
Unit definition
Operation permitted/prohibited Room temperature Time and date setting
Fan speedsOperation permitted/
prohibitedAlarm history
Air direction Fan speed Energy consumption calculation period
Filter sign reset Air direction
Filter sign
Energy consumption, cumulative operation time
Flap control setting
Operation data monitoring
Data logging (Run / Stop set temperature , room
temperature , outdoor air temperature )
Maintenance(1, 2 or back-up)
Outdoor airtemperature
Demand control (3 steps)
Emergency stop
Watt-hour meter pulse input
Collective operation output
Indoor unit 128 units
Ethernet 10 BASE-T/
100BASE-TX
Internet
Explorer HUB
Emergency stop signal input
PC requirements: Windows Vista or Windows 7, 8.1
Monitor resolution 1280 x 1024 or more.
Web browser requirements: Internet Explorer 9, 11
Electric power calculation function:(for SC-SL4-BE only)
Item Model SC-SL4-AE/SC-SL4-BE
Ambient temperature during use 0 ~ 40oC
Power supply 1 Phase 100-240V 50/60Hz
Power consumption 9W
External dimensions(Height x Width x Depth) 172mm x 250mm x 23 (+70) mm
Net weight 2.0kg
Number ofup to 128 unitsconnectable units (indoor units)
LCD touch panel Colour LCD, 9 inches wide
SL (Superlink) signal inputs
Watt-hour meter pulse input* 8-point, pulse width 80ms or more
Emergency stop signal input*1 point, non-voltage a contact input
continuous input (closed, forced stop)
Demand signal input*2 point, non-voltage a contact input
continuous input (closed, demand control)
1 point, maximum rated current 40mA, DC24 V
1 point maximum rated current 40mA, DC24 VNormal; closed. If even one unit is abnormal; Open
(Open/closed can be changed)
All units stop; Open, any unit operating;Close
*The receiving side power supply is DC 12V (10mA).The air conditioning charges calculations of this unit are not based on OIML, the international standard.
Inp
uts
Export data by
Calculation software
Watt-hour meterpulse input (Maximum)
Max connectable indoor units
USB / LAN
Included
8
128
SC-SL4-BE
SC-SL4-BE gives electric power consumption data (kWh) foreach indoor unit , each group, each SUPERLINK- II system,and each watt-hour meter input.
1 system (Super link- )
Operation output
Error outputOu
tpu
ts
<Central Control>
SC-SL1N-EStart/stop control of up to 16 indoor units either individually or collectively.
Simple centralised control.
1. The SC-SL1 N-E is connected to the Superlink-El network via 2-core, non-polar wires ('AB' connection).
2. It will monitor and control the start/stop function of up to 16 units, with the sixteen operation button.
3. The unit or group numbers in operation or in need of service are displayed with an LED.
4. Collective start/stop is also available through the simultaneous on/off button.
5. Up to 12 SC-SL1 N-E units can be connected to a Superlink- network (consisting of up to 128 indoor
units).
6. If a power failure occurs, the SC-SL1 N-E will resume the operation of the system according to a stored
operation condition, once power is restored.
SC-SL2NA-ECentral control of up to 64 indoor units including weekly timer function as standard.
1. The SC-SL2NA-E is connected to the Superlink- network via 2-core, non-polar wires
('AB' connection).
2. It will monitor and control the start/stop function of up to16 units, or 16 groups of units, with
the sixteen operation buttons.
3. It also monitors and controls the following functions for individual units, groups of units or the
complete network: operation mode, set point temperature, return air temperature, louvre
position, error code. Air flow and center lock function.
4. The unit or group numbers in operation or in need of service are displayed with an LCD.
5. Collective start/stop is also available through the simultaneous on/off button.
6. If a power failure occurs, the SC-SL2NA-E will resume the operation of the system according to
a stored operation condition, once power is restored.
7. The SC-SL2NA-E can be connected to an external timer to facilitate timed on/off cycles.
8. The number of units connected to one network are detailed on the table below.
•Applicable products
Ventilation fan, Air purifier
•By using SC-GIFN-E together with central control such as SC-SL1 N-E,
SC-SL2NA-E and SC-SL4-AE/BE, you can start-stop, operate & monitor
the operation of applicable products.
An SC-SL2NA-E performs the start/stop control, monitoring and mode setting of
up to 64 units. It is a high quality air conditioner control system that allows up to
64 indoor units to be freely grouped into 1 to 16 groups.
It allows not only the start/stop control but also the monitoring, display of
operation statuses such as in operation or in need of service and mode setting
such as switching of operation modes of connected units collectively, by
group or individually.
•Outer dimensions: H120 x W215 x D25+35*mm.
35" is the measurement including the part contained in a recess.
Note: Please consult company for combination of center controls and BMS interface units.
Example of control by a centre control SC-SL2NA-E
<Central Control>
SC-SL4-AE/BEMitsubishi Heavy Industries Thermal
Systems introduces the full colour touch
screen central control SC-SL4-AE/BE,
with 9 inch interactive LCD display.
Offers control, monitoring, scheduling
and service/maintenance functions for
up to 128 indoor units. Control with PC
is available by use of internet explorer.
Indoor units can be controlled,
scheduled, monitored and either
individually, as groups or as blocks of
groups with the following
functions:
16 17
Outdoor units
DX-AHU
Features
System configuration
System A System B
EEV-Control Assy has 2 types.EEV-Control Assy
Not Use 1 box-Many boxes
1 box (for master) Many boxes(for slave)
EEVKIT6-E-M
EEV6-71-E EEV6-160-E EEV6-280-E
22-71 90-160 224-280
EEVKIT6-E-C
EEV-Set Select from following 3 types according to the coil capacity.
Type
Capacity
Refrigeration system
Single
Multiple
EEV-Set
FAN
EEV-Set×2 sets
EEV-Control box×2 sets
FAN
DX : Direct expansion coil
EEV-KIT
EEV-KIT
FAN
Genuine Spares & Service Center
FDC335KXZE1
25.4, 12.7
5.0m (3)
DIS-371-1G15.88, 9.52
2.5m (1)
DIS-22-1G15.88, 9.52
2.0m (1)
DIS-22-1G12.7, 6.35
3.5m (3)
1. FDT36KXE6F
ASST. MANAGER CABIN 1 S/L00
15.88, 9.52
4.5m (2)
2. FDE71KXE6F
ASST. MANAGER CABIN 2 S/L01
12.7, 6.35
5.2m (3)
3. FDTW56KXE6F
ASST. MANAGER CABIN 3 S/L02
19.05, 12.7
5.0m (2)
DIS-180-1G12.7, 6.35
3.0m (2)
4. FDTS45KXE6F
ASST. MANAGER CABIN 4 S/L03
19.05, 12.7
3.0m (1)
DIS-180-1G19.05, 12.7
3.0m (0)
DIS-180-1G15.88, 9.52
3.0m (0)
DIS-22-1G12.7, 6.35
3.5m (2)
5. FDU45KXE6F
ASST. MANAGER CABIN 6 S/L04
15.88, 9.52
3.5m (3)
6. FDK71KXE6F
ASST. MANAGER CABIN 5 S/L05
15.88, 9.52
6.0m (3)
7. FDFL71KXE6F
ASST. MANAGER CABIN 8 S/L06
9.52, 6.35
6.0m (3)
8. FDFW28KXE6F
ASST. MANAGER CABIN 11 S/L07
R C N-E -E
RCN-K-E : FDK22~56
RCN-K71-E : FDK71
R C N-T -36W-E
R C N-T W-E
RCN-TS-E
RCN-KIT3-E
R C N-K IT 3-E
R C N-F W-E
• EEV-KIT is the control kit for operating the locally provided
AHU or FCU with direct expansion heat exchanger coils in
connection with the KXZ / KXE6 system.
(AHU : Air Handling Unit, FCU : Fan Coil Unit)
• EEV-KIT is composed of one EEV-Control ASSY and one
EEV-Set.
•Single refrigeration system EEVKIT6-E-C Possible with multiple
•Multiple refrigeration system EEVKT6-E-M (1) + EEVKIT6-E-C
Possible with multiple (Max32)
•EEVKIT6-E-C is common for both single and multiple refrigeration systems
Single refrigerant system• Single refrigeration system is one that can have multiple outdoor units on one refrigerant pipe work circuit.
• There are 2 types of EEV-KIT systems that can be built into the single refrigeration system.
• System A : one EEV-KIT.
• System B : multiple EEV-KIT's.
• This system has only one set of EEV-KIT built into one
indoor unit with only one heat exchanger. This system can
be applied to an indoor unit whose capacity is up to 10HP.
• System B is a system that has multiple EEV-KIT's built into one indoor unit
with multiple heat exchangers on one refrigerant circuit.
• This system can be applied up to 60HP(for KXZ), 48HP(for KXE6)AHU
capacity.
Multiple refrigerant system1) Multiple independent refrigerant circuits
2) One master control to control the whole system.
Advantage
• Large systems are possible [max capacity 896kW (Indoor unit : 28kW x 32)]
• External control
• Capacity step control
Additional parts over a single refrigeration system
• One master control
The slave EEV control and EEV set are the same as a single refrigeration
system.
AHU CONNECTING KIT Design Software Tool : E-Solution
18 19
Alliance Profile : Mitsubishi Heavy industries -
IAPL Group
Mitsubishi Heavy Industries — IAPL Group is a strategic alliance of Mitsubishi Heavy Industries — Mahajak
Airconditoners Co. Ltd. & IAPL Group, for sales & marketing of Mitsubishi Heavy Ind. Heavy Duty Room & Semi
Commercial Airconditioners in South East Asian Countries, including India, Indoneasia, Malyasia & Singapore. We are
known for our commitments for high standards of service. We have a proven experience of more than 30 years in
multifaceted business. We have a wide customer base for Mitsubishi Heavy Duty Airconditioners in India and
international markets & have rich experience in managing a network in Asian countries for supply, installation, testing
& commissioning Mitsubishi Heavy Duty Room & Commercial AC & VRF System.
IAPL GROUP with its nationwide network has supported a wide array of projects including residential & large
commercial establishment/ Parks, Offices, Business establishments, Hotels, Hospitals, Schools, Commercial
Complexes, Industries, Marriage Halls etc. We have participated in projects for large Air Conditioning Systems
requiring SYSTEM INTEGARATION of imported air conditioning equipment as per the international standards lay down
by our principals — M/s. Mitsubishi Heavy Industries We ensure much superior quality of workmanship with advanced
engineering skills. We have full-fledged team of qualified engineers and technical staff in the air-conditioning divisions
to meet all kind of requirements. IAPL GROUP has consistently provided Channel Partners with timely and high value
service, competitively priced products without sacrificing quality.
IAPL GROUP has more than 1500 Channel Partners spread across the country to extend & provide necessary sales &
support for the products and services distributed thru them.
IAPL GROUP has its branch offices in all the major cities of India including Delhi, Mumbai, Chennai, Kolkatta,
Bangalore, Ahmedabad, Hyderabad, Jaipur, Chandigarh, Lucknow, Cochin, Fardiabad, Mohali, Ghaziabad,
Ludhiana, Jammu & Kashmir, Indore & Dehradun. Company has Authorized Sales & Service Channel Partners at all
major cities of India. The back up of advanced engineering skills, technical expertise and resources including training
& spares availability, are supported by us.
We at IAPL GROUP believe in continuous innovation to source superior quality products and extend services to our
channel partners and customers as per the standards recommended by our principals M/s. MITSUBISHI HEAVY
INDUSTRIES —JAPAN . Our objective is to have continuous access to new technology and adapt to effectively
understand changing customer needs in the present day liberated environment. In this process we aim to provide our
customers with Effective after Sales Service & Spares Support, which is monitored through response time. We work as a
friendly HVAC Solution Provider to all our most valuable clients.
Our Installation & after sales & services is managed 18 Branches in India and extended thru 78 no.s MHI — Genuine
Spares & Service Center, having genuine spares stocks as well as having experienced team of company trained
Service Engineers & Service Technicians for Maintenance of Air conditioning equipments . They are trained at the
factory of Mitsubishi Heavy Industries, for product trouble shooting and in providing effective support to our Channel
Partners and Customers.
We maintain spares at our Mother Warehouse at Delhi & our 14 branches as well as MHI-Genuine Spares & Service
Centers. This is to reduce the down time as much as possible.
We at IAPL GROUP have adopted several methods for quality control in terms of designing, quoting, erection &
commissioning of supply, installation, testing & commissioning of the Mitsubishi Heavy Duty Airconditioners.
The quality control process will comprise of storage of standardized material, standard of workmanship, testing and
checking of works as per the standards laid down by our principals MITSUBISHI HEAVY INDUSTRIES.
PRODUCTION PROCESSThe system features following factors.
1. YATAI or cell Production
• Multi Model Production • Multi Skill Production • Small Lot Production
2. Changing from Push to Pull System
• Synchronize to Assembly • First In First Out (FIFO)
3. Visual Control System
• Kanban • Undon
4. Reduction of Production Lead Time and Work in Process Stock
5. Introduction of KAIZEN Activity (Continuous Improvement) in the factory at all times