york vrf catalog

52
YES Slim & YES Super Series COMMERCIAL DC INVERTER VRF AIR-CONDITIONERS YOU CAN TRUST

Upload: vijay-kumar

Post on 26-Sep-2015

736 views

Category:

Documents


93 download

DESCRIPTION

VRF Catalog

TRANSCRIPT

  • YES Slim & YES Super Series CommerCial DC inverter vrF air-ConDitioners You Can trust

  • Table of Contents

    Serving your needs since 1874 1

    Product Benefits 3

    Product Features 4

    Product Functions 8

    Product Technologies 11

    Indoor Units 21

    Smart Control 27

    Fresh Air System 31

    Product Nomenclature 33

    Product Portfolio 34

    Product Specifications 36

  • YES Slim & YES Super | 1

    A century of innovation

    Established in 1874 in York, Pennsylvania, YORK has

    helped our customers meet their temperature control

    needs for over a century.

    Now a Johnson Controls brand, YORK continues to

    benefit customers through research that has gone on to

    claim several significant firsts in design and innovation.

    Johnson Controls is able to provide our customers with

    the best temperature control solutions available around

    the world today.

    Pioneer in Inverter technology

    Our customers can be assured that they will enjoy the

    benefits of the latest technology when they choose a

    Johnson Controls product, as YORK has always been

    at the forefront of adopting new technologies for their

    offerings.

    From being the first to offer a low pressure VSD unit in

    1979 to introducing the inverter technology in the 21st

    century, YORK has demonstrated its pioneering spirit.

    Leader in reliability

    When constructing products, YORK places our

    customers needs as the top priority of our design

    process.

    Our inverter VRF units are produced using state-of-

    the-art lean manufacturing techniques, and rigorous

    quality testing is implemented at every step of the

    manufacturing process, before they are shipped to

    customers.

    Significant Milestones

    1935First to develop a successful single-room air conditioner

    1954First to offer year-round air-conditioning

    1979launched the first low Pressure vsD Driven Centrifugal Chiller

    2004launched the first vsD Driven air Cooled screw Chiller

    2005applied vsD in YorK industrial refrigeration screw Chiller

    2011launched the Yes mini residential inverter vrF, magnetic vsD Centrifugal Chiller, vsD Driven Water Cooled screw Chiller

    2012launched the Yes slim residential/ Commercial inverter vrF, Yes super Commercial inverter vrF

    Serving Your Needs Since 1874.

  • 2 | YES Slim & YES Super

    Endorsed by Iconic Buildings.

    2 | YES Slim & YES Super

    YORKs HVAC systems have been installed in many of the worlds most famous landmarks. YORK makes sys-

    tems for structures of all sizes that bring innovation, comfort and design wherever people live, work and play.

  • YES Slim & YES Super | 3

    YORK Variable Refrigerant Flow (VRF)

    At Johnson Controls, we always seek to anticipate what customers are looking for and strive to provide the

    temperature control systems that will meet their myriad of needs.

    YORK VRF air-conditioners offer customers a range of benefits that is unparalleled in the air-conditioner

    market.

    Energy Efficient

    Customers looking to save money will be delighted to know our air-conditioners can help

    reduce costs as the highly energy-efficient VRF units will help you decrease the power

    you use.

    Wide Ambient Range

    Customers can take comfort in knowing that our inverter VRF air-conditioners can

    operate in extreme weather conditions, running safely even when ambient temperature is

    up to 52C for cooling or -20C for heating.

    48 to 52C cooling for YES Slim & YES super or -15 to -20C heating for YES Slim will be running at intervals.

    Smart Control

    Customers can take more effective control of their air-conditioners with a variety of

    technology tools available for our units. Our advanced suite of control solutions include:

    three types of touch screen controllers, smart home connection and building automation

    systems using the Metasys software.

    Versatility

    We understand that no two customers are the same. Thats why weve designed our

    air-conditioning systems to be versatile enough to meet our customers differing needs.

    From product selection to installation to commissioning, YORK YES Series offers

    impressive flexibility.

    Greater Comfort

    We know that enjoying comfort at the right temperature is one of our customers

    foremost desires. We have the technology to deliver that comfort, including a BLDC

    (Brushless Direct Current) fan motor with adjustable speeds, anti-vibration and sound-

    insulation technology.

    Product Benefits

  • 4 | YES Slim & YES Super

    Environmental Protection

    Our highly energy efficient Inverter VRF units provide environmental protection by

    using the eco-friendly R410A refrigerant.

    Air Cooled Inverter Driver

    They also carry the air cooled inverter driver, a core component which uses air-cooled

    heat rejection technology for higher energy efficiency.

    Independent Oil Circuit Design

    The independent oil circuit design allows the oil balance system to be kept separate from the

    cooling and heating operation, thereby avoiding the frequent switching of the compressor and im-

    proves sustainability and energy efficiency.

    Outdoor unit Outdoor unit

    Oil balance pipe between units

    Oil transport distribution station

    52C -20C

    Product Features

    Wide Ambient Range

    With wide ambient temperatures ranging from 52C in cooling mode to -20C in heat-

    ing mode, the outdoor unit can work in any adverse environment

    High ESP Discharge Air

    The ESP discharge air of the system can reach up to 80 Pa, which guarantees stable

    cooling and heating, making it suitable for any outdoor space or machine rooms of multi-

    storey structures.

    Touch Screen Wired Controller

    Take control of your system with our touch screen wired controller that is available in

    four different colours. It has a built-in wireless remote controller receiver to control the

    indoor unit, as well as a real-time temperature sensor.

  • YES Slim & YES Super | 5

    Multi-point Data Collection

    Maintain and repair your outdoor units easily with a Service Controller, which allows to

    be connected to any indoor unit in the same network to do multi-point data collection.

    Outdoor Unit Anti-Corrosion Fins

    Our units also have outdoor unit anti-corrosion fins which are made from hydrophilic

    aluminium and help the outdoor units defrost quickly and get rid of condensation. The

    anti-corrosion coating and wave-shape reduces the cutting surfaces, thereby prolonging

    the life of the fin significantly.

    Combined Electronic Expansion Valves and Check Valve Throttle Device

    With a commitment to fine quality, our VRF units make use of the combined electronic

    expansion valves and check valve throttle device which helps to prolong product

    usage by reducing the working time of the electronic expansion valve. Our large capac-

    ity outdoor units are equipped with double electronic expansion valves, which increase the

    response speed of the flow control and heating mode.

    Complete System Protection for High Reliability

    Our VRF air-conditioners come thoroughly equipped with a complete system protec-

    tion for high reliability, which includes:

    Communication Fault Protection Inverter Fault Protection

    Temperature Sensor Protection Pressure Sensor Protection

    Insufficient Refrigerant Protection Compressor Fault Protection

    Compressor Overcurrent Protection BLDC Fault Protection

    Discharge Temperature Protection Discharge Pressure Protection

    Suction Pressure Protection Low Pressure Switch Protection

    Intelligent Debugging Operation

    With an intelligent debugging operation, an alarm will be triggered if any com-

    munication errors are detected between the indoor and outdoor units. Automatic

    alerts will also be sent when service stop valves are opened or closed.

    Wave-shaped Fin

    Decrease cutting surface to reduce corrosion risk

    Water do not accumulate in the gap between fins and can drip down easily to reduce corrosion risk.

    Water does not accumulate in the gap between fins and can drip down easily to reduce corrosion risk.

  • 6 | YES Slim & YES Super

    Improved Indoor Air Quality

    Nano-TiO2 sterilizers are also in place, which enables up to 95% completion of steriliza-

    tion in 6 hours, allowing improved indoor air quality.

    Moderate Height Difference Allowance

    From installation to commissioning to product selection, YORK YES Series offers

    unparalleled flexibility. For example, moderate height difference allowance enables

    outdoor units with some height difference to be installed within the same system.

    Intelligent Weather-Proofing

    You can now maximise comfort throughout the day with our inverter VRF air-condition-

    ers as they come with intelligent weather-proofing that allows pressure and tempera-

    ture sensors to collect pre/post-defrosting data to derive the optimal defrost setting,

    maintaining a high performance in heating and cooling operations under strong winds.

    Ultraviolet Photo Catalysis

    Nano-TiO2 Nano-TiO2

    Polluted Air

    Polluted Air

    Fresh Air

    Refrigerant Connect To Indoor Units

    Height Difference Between Modular Less Than 5m

  • YES Slim & YES Super | 7

    Double Fan Design and Noise Reduction Technology

    The double fan design, which enables a lower airflow volume as compared to a single

    fan, and the noise reduction technology, made possible by DC Scroll inverter compres-

    sors, BLDC fan motor with adjustable speeds, anti-vibration and sound-insulation tech-

    nology, ensures that the air-conditioners operate quietly by cutting down the operational

    noise levels.

    Non-stop Oil Return at Heating

    Through the computation of accumulated operation time, real-time system partial load-

    ing, temperature and pressure data, the system can determine when to activate the non-

    stop oil return at heating without switching to cooling mode, thereby offering continu-

    ous heating to the users.

  • 8 | YES Slim & YES Super

    Product FunctionsOptimization in Operation of Indoor Units

    Our system can detect and promptly compare real-time pressure and temperature pa-

    rameters, then optimizes the indoor unit operation by automatically adjusting the pres-

    sure and compressor running frequencies.

    Intelligent Defrost

    Our intelligent defrost system ensures comfort at heating.

    Silent Operation Function

    The outdoor unit also automatically detects real-time changes in environmental tem-

    perature and operation pressure, and adjusts to silent mode accordingly.

    Auto-restart Function

    In case of accidental power failure, the system auto-restarts and recovers to the former

    operation mode.

    High PressureSensor

    Low PressureSensor

    Far end indoor units refrigerant flow increased

    Operation mode before power cut off

    Automatic restart and Recovery recover to the operation mode before

    power cut off

    After 1hr

    Heat storage and

    defrost

    Humidity defrost at ultra

    extra-low temperatur

    e

    Defrost on-deman

    d by

    pressure & tem

    perat

    ure

    Operation mode before power cut off

    Automatic restart and recovery to the operation mode

    High PressureSensor

    Low PressureSensor

    Far end indoor units refrigerant flow increased

    Operation mode before power cut off

    Automatic restart and Recovery recover to the operation mode before

    power cut off

    After 1hr

    Heat storage and

    defrost

    Humidity defrost at ultra

    extra-low temperatur

    e

    Defrost on-deman

    d by

    pressure & tem

    perat

    ure

  • YES Slim & YES Super | 9

    LED Display

    The diagnosis and display of LED error codes helps shorten service time by technicians.

    Refrigerant Recovery

    If the indoor unit or outdoor unit fails in the system, the refrigerant can be recovered to

    reduce its wastage.

    Max Operating Frequency Setting Function

    When there is a limited capacity of power distribution, users have the option to set a

    maximum compressor frequency ratio, ensuring economical returns and stability.

    Can set max compressor frequency

    Tackles the lack of power distribution in renovation of buildings

    More economical and stable

    Better performance in case of a power shortage

    Maximum Frequency Limit Operation

    Compressor Rotation Operation

    The compressor rotation operation effectively spreads the operation time of each

    compressor,extending the unit life.

    1st Circle:

    2nd Circle:

    3rd Circle:

  • 10 | YES Slim & YES Super

    1st Circle:

    2nd Circle:

    3rd Circle:

    Single Modular Combination Units

    Stop Running Backup Running Backup Running

    Precision

    Fast Step Jump

    Traditional Inverter Technology

    YORK Inverter Technology

    Normal 120Communication Square Wave Drive Mode

    YORK 180Communication Sine Wave Drive Mode

    Phase Current Phase Current

    U Phase

    V Phase

    W Phase

    U Phase

    V Phase

    W Phase

    Failed

    Failed

    Double Backup Operation

    If one compressor fails, the other compressor(s) can keep running if no oil contamination

    occurs.

    If one outdoor unit fails, the other outdoor unit(s) can keep running if no oil contamina-

    tion occurs.

  • YES Slim & YES Super | 11

    Product TechnologiesStepless Inverter Technology

    Our system adopts advanced DC inverter drivers with higher sensitivity, lower power

    consumption and lower heat loss. It keeps a good balance between the accuracy of ad-

    justment and response time, thereby ensuring a fast response and enough accuracy. The

    accuracy of adjustment can reach 0.01HZ, and the capacity can be adjusted steplessly.

    1st Circle:

    2nd Circle:

    3rd Circle:

    Single Modular Combination Units

    Stop Running Backup Running Backup Running

    Precision

    Fast Step Jump

    Traditional Inverter Technology

    YORK Inverter Technology

    Normal 120Communication Square Wave Drive Mode

    YORK 180Communication Sine Wave Drive Mode

    Phase Current Phase Current

    U Phase

    V Phase

    W Phase

    U Phase

    V Phase

    W Phase

    Failed

    Failed

    180DC Inverter Driver Control Technology

    YES S Series adopts the advanced phase voltage signal sampling method, and can mea-

    sure the force trends of the motor speed and rotor, improving the running efficiency of

    the motor through having the DC inverter driver transmit regular sine-curve waves.

    There are three groups of terminals in the inverter compressor electric box, providing the

    DC inverter driver access to the terminal to drive the stator coil of the DC brushless mo-

    tor within the compressor. The connected circuit, under a certain time order, has the DC

    motor generate a 360 magnetic field.

    A 180 DC inverter control enables the stator coil to always have current steadily running

    through to make it stable.

    Precision

    Fast Step Jump

    Traditional Inverter Technology

    YORK Inverter Technology

  • 12 | YES Slim & YES Super

    High Performance Mainboard Chip

    Our outdoor units use the ARM CORTEX-M3, which has the 32Bit

    72Mhz high-speed chip.

    This chip has the highest performance in the industry, and im-

    proves the calculation efficiency of the DC inverter while reducing

    the power consumption of the transformer or other system parts. 4 8 12 16 20 24 28 32

    23

    4

    a a

    b

    bc c

    1,

    2,

    3,

    1

    d

    lg p

    h

    Strong Magnetic Rotor of Compressor Motor

    Traditional Compressor Motor

    Capacity HP

    Time Min

    System Refrigerant Circulation Diagram (Pressure-Enthalpy) High Pressure Chamber Scroll Compressor

    Other refrigerant system diagramYORK high pressure cell refrigerant system diagram

    DC Brushless Fan Motor

    DC Brushless Fan Motor

    Compressor Inverter Driver

    Powerful Permanent Magnets

    Our compressor motor rotors use powerful permanent magnets

    made from rare earth. Compared with the normal ferrite mag-

    nets, it has stronger magnetic and heat resistance, which provides

    greater torque, lower power consumption, with higher reliability

    and energy efficiency.

    DC Inverter Technology

    Our YES-S Series outdoor units feature the DC inverter compressor and DC fan motor,

    which enable more efficient and quiet operations.

  • YES Slim & YES Super | 13

    Soft Start

    Variable frequency soft start technology can achieve the required capacity output of

    indoor units within a short period.

    4 8 12 16 20 24 28 32

    23

    4

    a a

    b

    bc c

    1,

    2,

    3,

    1

    d

    lg p

    h

    Strong Magnetic Rotor of Compressor Motor

    Traditional Compressor Motor

    Capacity HP

    Time Min

    System Refrigerant Circulation Diagram (Pressure-Enthalpy) High Pressure Chamber Scroll Compressor

    Other refrigerant system diagramYORK high pressure cell refrigerant system diagram

    DC Brushless Fan Motor

    DC Brushless Fan Motor

    Compressor Inverter Driver

    4 8 12 16 20 24 28 32

    23

    4

    a a

    b

    bc c

    1,

    2,

    3,

    1

    d

    lg p

    h

    Strong Magnetic Rotor of Compressor Motor

    Traditional Compressor Motor

    Capacity HP

    Time Min

    System Refrigerant Circulation Diagram (Pressure-Enthalpy) High Pressure Chamber Scroll Compressor

    Other refrigerant system diagramYORK high pressure cell refrigerant system diagram

    DC Brushless Fan Motor

    DC Brushless Fan Motor

    Compressor Inverter Driver

    High Pressure Chamber Scroll Compressor

    High pressure chamber scroll compressors directly gets the suction refrigerant from the

    indoor unit back to the compression cylinder. The refrigerant is not heated by the mo-

    tor, so it can get a better compression ratio and a relatively high energy efficiency. The

    pressure of the refrigerant with high temperature and pressure in the crank case can be

    adjusted automatically. and then discharged from the exhaust, which has a similar func-

    tion as the static pressure box, and allows the noise to be effectively controlled.

    High-efficiency Oil Separator

    The cover of the oil separator uses a centrifugal rotary steering design. Refrigerant gas

    goes into the oil separators and then immediately gains a high rotating speed. This,

    together with the centrifugal force separates the heavier oil gas from the refrigerant. The

    oil gas is liquefied and finally drops to the storage device across the walls of the separa-

    tor, thereby finishing the separation process.

    4 8 1216 20 24

    28 32

    2

    3

    4

    a a

    b

    bc c

    1,

    2,

    3,

    1

    d

    lg p

    h

    Strong Magnetic Rotor of Compressor Motor

    Traditional Compressor Motor

    Capacity HP

    Time Min

    System Refrigerant Circulation Diagram (Pressure-Enthalpy)

    High Pressure Chamber Scroll Compressor

    Other refrigerant system diagram

    YORK high pressure cell

    refrigerant system diagram

    DC Brushless Fan Motor

    DC Brushless Fan Motor

    Compressor Inverter Driver

  • 14 | YES Slim & YES Super

    Non-stop Compressor, Cross Oil Balance Protection Technology

    Through reasonable oil control logic, with the large volume of accumulator (with oil

    storage function), and the specific tubing, the system can complete the cross oil bal-

    ance protection process. The compressor does not need to stop throughout the whole

    process, making the operation of the air-conditioning system more reliable and efficient

    while without affecting the indoor effect.

    Application of Oil balance on Single Unit

    Application of Oil balance on combined units

    Discharge

    Suction

    ON

    2

    1ONOFF

    OFF

    SV Close SV Open

    YORK Chiller Multiple Deep Oil Separating Technology

    YORK Inverter VRF Double Oil Separating Technology

    Oil separator in condenser

    Evaporator

    Discharge pipeInside oil separation

    Double oil separation pipeline

    Compressor

    Filter

    Liquid supply line

    Evap

    orator oil

    return pipe

    Nozzle with injector

    Triple oil separation pipeline

    Suction pipe

    Ref. routeOil route

    Compressor discharge

    Compressor, with oil separation function inside

    First oil separation

    System discharge

    Compressor suction

    Oil se

    parator

    Accum

    ulator

    System suction (liquid)

    Oil return

    Double oil separation

    High pressure sensor

    Flow of refrigerant

    High pressure discharge chamber

    Connected to low pressure suction end of asymmetric vortex plate

    Pressure-difference oil pipe

    The formation of continuous oil film

    Oil balance between the unit inside compressors: After the oil in the second compressor is separat-ed in the oil separator, it will enter the crank case oil groove in the first compressor by oil pipe, and after the oil in the first compressor is separated in the oil separator, it will enter the accumulator oil groove by pipe. Oil will be transported to two compressors by suction pipe, so the compressor does not need to stop and ensure that two compressors can gain lubrication by oil at the same time.

    Oil balance between modules uses the pressure-difference method. After separation in the oil seperator, the oil is divided into two branches, with one of them flowing to the liquid separator and the other one going into another module. The oil pressure in oil separator is high and the oil pressure in liquid is low. When the solenoid valve in branch to another module (1) is open, and the solenoid valve in liquid separator pipe of another module (2) is open, the differential pressure will automatically engage the oil from oil separator of the first module to liquid separator of the second module, thus completing the oil balance between modules.

  • YES Slim & YES Super | 15

    Double Oil Separation Technology

    This technology ensures the compressor is neither in short nor excessive supply of oil,

    thereby guaranteeing high reliability and efficiency. Since deep oil separation technology

    has been in application on large variable frequency chillers for many years, inverter VRF

    also refers to the experience of large systems, using double oil cleaning technology. The

    compressor has an oil separation function, and a newly added high-efficiency oil separa-

    tor to do double oil separation at the same time.

    Application of Oil balance on Single Unit

    Application of Oil balance on combined units

    Discharge

    Suction

    ON

    2

    1ONOFF

    OFF

    SV Close SV Open

    YORK Chiller Multiple Deep Oil Separating Technology

    YORK Inverter VRF Double Oil Separating Technology

    Oil separator in condenser

    Evaporator

    Discharge pipeInside oil separation

    Double oil separation pipeline

    Compressor

    Filter

    Liquid supply line

    Evap

    orator oil

    return pipe

    Nozzle with injector

    Triple oil separation pipeline

    Suction pipe

    Ref. routeOil route

    Compressor discharge

    Compressor, with oil separation function inside

    First oil separation

    System discharge

    Compressor suction

    Oil se

    parator

    Accum

    ulator

    System suction (liquid)

    Oil return

    Double oil separation

    High pressure sensor

    Flow of refrigerant

    High pressure discharge chamber

    Connected to low pressure suction end of asymmetric vortex plate

    Pressure-difference oil pipe

    The formation of continuous oil film

    Application of Oil balance on Single Unit

    Application of Oil balance on combined units

    Discharge

    Suction

    ON

    2

    1ONOFF

    OFF

    SV Close SV Open

    YORK Chiller Multiple Deep Oil Separating Technology

    YORK Inverter VRF Double Oil Separating Technology

    Oil separator in condenser

    Evaporator

    Discharge pipeInside oil separation

    Double oil separation pipeline

    Compressor

    Filter

    Liquid supply line

    Evap

    orator oil

    return pipe

    Nozzle with injector

    Triple oil separation pipeline

    Suction pipe

    Ref. routeOil route

    Compressor discharge

    Compressor, with oil separation function inside

    First oil separation

    System discharge

    Compressor suction

    Oil se

    parator

    Accum

    ulator

    System suction (liquid)

    Oil return

    Double oil separation

    High pressure sensor

    Flow of refrigerant

    High pressure discharge chamber

    Connected to low pressure suction end of asymmetric vortex plate

    Pressure-difference oil pipe

    The formation of continuous oil film

    Over Compression Prevention Technology

    The load and requirement of refrigerant in VRF systems are changing. As the load volume

    can influence frequency, whether the system is intelligent makes a big difference.

    1. The system uses a high-pressure sensor to detect the

    discharge pressure, then adjusts the fan motor to ensure the

    discharge pressure does not exceed the allowable range.

    2. Pressure relief vents are available in the compressor cylinder.

    When over-compression happens, the corresponding

    pressure-relief vents will be automatically pushed against the

    linked spring to release pressure and refrigerant gas, thereby

    preventing over compression.

    Application of Oil balance on Single Unit

    Application of Oil balance on combined units

    Discharge

    Suction

    ON

    2

    1ONOFF

    OFF

    SV Close SV Open

    YORK Chiller Multiple Deep Oil Separating Technology

    YORK Inverter VRF Double Oil Separating Technology

    Oil separator in condenser

    Evaporator

    Discharge pipeInside oil separation

    Double oil separation pipeline

    Compressor

    Filter

    Liquid supply line

    Evap

    orator oil

    return pipe

    Nozzle with injector

    Triple oil separation pipeline

    Suction pipe

    Ref. routeOil route

    Compressor discharge

    Compressor, with oil separation function inside

    First oil separation

    System discharge

    Compressor suction

    Oil se

    parator

    Accum

    ulator

    System suction (liquid)

    Oil return

    Double oil separation

    High pressure sensor

    Flow of refrigerant

    High pressure discharge chamber

    Connected to low pressure suction end of asymmetric vortex plate

    Pressure-difference oil pipe

    The formation of continuous oil film

  • 16 | YES Slim & YES Super

    Continuous Oil Film Lubricating Technology

    The oil supply in the compressor is pow-

    ered by the pressure difference in the high-

    pressure chamber and creates consistently

    stable oil film adherent to the wall, pro-

    moting the effective lubrication between

    the moving and fixed scrolls, sealing of

    compression chamber, cooling of the wall

    of the cavity, etc and reducing the friction

    loss and noise in the operation.

    Application of Oil balance on Single Unit

    Application of Oil balance on combined units

    Discharge

    Suction

    ON

    2

    1ONOFF

    OFF

    SV Close SV Open

    YORK Chiller Multiple Deep Oil Separating Technology

    YORK Inverter VRF Double Oil Separating Technology

    Oil separator in condenser

    Evaporator

    Discharge pipeInside oil separation

    Double oil separation pipeline

    Compressor

    Filter

    Liquid supply line

    Evap

    orator oil

    return pipe

    Nozzle with injector

    Triple oil separation pipeline

    Suction pipe

    Ref. routeOil route

    Compressor discharge

    Compressor, with oil separation function inside

    First oil separation

    System discharge

    Compressor suction

    Oil se

    parator

    Accum

    ulator

    System suction (liquid)

    Oil return

    Double oil separation

    High pressure sensor

    Flow of refrigerant

    High pressure discharge chamber

    Connected to low pressure suction end of asymmetric vortex plate

    Pressure-difference oil pipe

    The formation of continuous oil film

    %

    RPM

    100

    080

    060

    040

    020

    0100 200 300 400 500 600 700 800 900 1000

    BLDC Motor

    AC Motor

    Effic

    ienc

    y

    Speed

    Internal tread piping

    Gas refrigerant

    Gas refrigerant

    Gas refrigerant

    Liquid refrigerant

    Liquid refrigerant

    Liquid refrigerant

    Traditional ref. circuit design

    New-type ref. circuit design

    Increase liquid status to improve heat exchange efficient

    GasGas-liquid mixture

    Liquid

    3-row heat-exchanger

    Up to 20C sub-cooling

    Ref.

    Intelligent Refrigerant Storage Technology

    1. Through the high and low pressure sensors which control the amount of compres-

    sion and discharge of the compressor, the excess refrigerant is stored in the pipeline

    of the system.

    2. The accumulator provides storage space required for both defrosting and oil return,

    thus preventing the compressor from operating with liquid slugging. This ensures that

    the system runs with higher reliability and stability.

    Powerful Permanent Magnets

    Outdoor dual fans are configured with high efficient, low noise BLDC motor and up to

    40-step air-flow adjustment, enabling more accurate unit capacity output.

  • YES Slim & YES Super | 17

    Integral Design of Axial-flow Fan & Fan Guide Technology

    According to our research, reduction of the axial-flow fan blades and fan guide space can

    enhance the aerodynamic performance. When the ratio of tip clearance and fan diameter

    decreases from 3% to 1%, air flow can increase by 10%, thus improving the efficiency of

    the fan motor and reducing noise.

    %

    RPM

    100

    080

    060

    040

    020

    0100 200 300 400 500 600 700 800 900 1000

    BLDC Motor

    AC Motor

    Effic

    ienc

    y

    Speed

    Internal tread piping

    Gas refrigerant

    Gas refrigerant

    Gas refrigerant

    Liquid refrigerant

    Liquid refrigerant

    Liquid refrigerant

    Traditional ref. circuit design

    New-type ref. circuit design

    Increase liquid status to improve heat exchange efficient

    GasGas-liquid mixture

    Liquid

    3-row heat-exchanger

    Up to 20C sub-cooling

    Ref.

    %

    RPM

    100

    080

    060

    040

    020

    0100 200 300 400 500 600 700 800 900 1000

    BLDC Motor

    AC Motor

    Effic

    ienc

    y

    Speed

    Internal tread piping

    Gas refrigerant

    Gas refrigerant

    Gas refrigerant

    Liquid refrigerant

    Liquid refrigerant

    Liquid refrigerant

    Traditional ref. circuit design

    New-type ref. circuit design

    Increase liquid status to improve heat exchange efficient

    GasGas-liquid mixture

    Liquid

    3-row heat-exchanger

    Up to 20C sub-cooling

    Ref.

    %

    RPM

    100

    080

    060

    040

    020

    0100 200 300 400 500 600 700 800 900 1000

    BLDC Motor

    AC Motor

    Effic

    ienc

    y

    Speed

    Internal tread piping

    Gas refrigerant

    Gas refrigerant

    Gas refrigerant

    Liquid refrigerant

    Liquid refrigerant

    Liquid refrigerant

    Traditional ref. circuit design

    New-type ref. circuit design

    Increase liquid status to improve heat exchange efficient

    GasGas-liquid mixture

    Liquid

    3-row heat-exchanger

    Up to 20C sub-cooling

    Ref.

    2. The pipe is processed with internal tread piping that can add more turbulence to the

    flow of the refrigerant and enlarge the heat-exchanging surface. Also, it adopts cor-

    rugated expansion-connected fins to add air passageway and heat transmission of

    the gas on the air-cooling side.

    3. The advanced 2-in and 1-out circuit design can increase the proportion of liquid

    refrigerant and the heat exchanging rate of the refrigerant, thereby enhancing heat

    exchanging effect and efficiency.

    High-efficiency Heat Exchanger

    1. For large-capacity units, it uses 3-row

    heat-exchangers to improve heat

    emission in summer and endothermic

    ability in winter to ensure the heat

    exchange effect.

  • 18 | YES Slim & YES Super

    High-efficiency Plate Heat Exchanger Sub-cooling Technology

    In order to ensure long piping's performance, a plate-type heat exchanger is used as a

    sub-cooler to achieve up to 20C sub-cooling temperature.

    %

    RPM

    100

    080

    060

    040

    020

    0100 200 300 400 500 600 700 800 900 1000

    BLDC Motor

    AC Motor

    Effic

    ienc

    y

    Speed

    Internal tread piping

    Gas refrigerant

    Gas refrigerant

    Gas refrigerant

    Liquid refrigerant

    Liquid refrigerant

    Liquid refrigerant

    Traditional ref. circuit design

    New-type ref. circuit design

    Increase liquid status to improve heat exchange efficient

    GasGas-liquid mixture

    Liquid

    3-row heat-exchanger

    Up to 20C sub-cooling

    Ref.

    Intelligent Piping Length Adaption Technology

    The system mainly uses high and low pressure as data for control. As for long piping,

    indoor electronic expansion valve and outdoor sub-cooling can self-adapt in accordance

    with the target low pressure, which can not only ensure long-distance delivery of cooling

    capacity, but also solve the problem of bias indoor flow, sparing human setting codes for

    pipe length, increasing integral comfort of the room and considerably saving debugging

    work during installation.

    Automatically close to target pressure

    Automatically determine pressure loss

    Automatically improve capacity correction

    Target pressure

    Long pipinginstallation

  • YES Slim & YES Super | 19

    8 6 4 2 0 -2 -4 -6 -8 -10

    Automatically close to target pressure

    Automatically determine pressure loss

    Automatically improve capacity correction

    Target pressure

    Long piping installation

    Chronic freezing, intelligent extra low temperature defrost

    Frosting reaches a certain level, defrosting

    No frost, no need to defrost

    Frosting probability

    Chronic freezing probability

    Environmental temperature

    Defrost cycle and strength adaption

    Heating Capacity

    Time

    DefrostHeating

    Heating

    Below -3 Intellige

    nt

    Defrost

    Over -

    3 Intelligent Defrost

    Outdoor coil

    Indoor unit

    Accumulator

    Adjust electronic expansion valve

    Indoor unit begins heat storage

    Reduce low temperature refrigerant

    Intelligent Defrost Technology

    1. YORKs unique heat storage defrost technology

    Before entering the defrost operation, the system will store an amount of heat for

    defrost later. (This operation does not compromise the indoor comfort).

    So it can reduce the liquid refrigerant return flow while defrosting, and can let the

    refrigerant carry more calories and evaporate faster. This results in faster defrosting

    by 50% compared to regular systematic defrosting.

    It can also speed up the the heating after defrosting for better comfort. By contribut-

    ing to the normal operation of compressors, it can ensure the system running stably

    and reliably, increasing the defrost efficiency and the actual energy efficiency of the

    whole system.

    2. Defrost on demand

    Our outdoor unit design has high-

    accuracy pressure and temperature

    sensors. Through close cooperation,

    they can detect the changes in

    system data caused by outdoor

    unit frosting, such as the pressure,

    temperature, duration of time, etc. and

    then calculate the thickness of frost

    8 6 4 2 0 -2 -4 -6 -8 -10

    Automatically close to target pressure

    Automatically determine pressure loss

    Automatically improve capacity correction

    Target pressure

    Long piping installation

    Chronic freezing, intelligent extra low temperature defrost

    Frosting reaches a certain level, defrosting

    No frost, no need to defrost

    Frosting probability

    Chronic freezing probability

    Environmental temperature

    Defrost cycle and strength adaption

    Heating Capacity

    Time

    DefrostHeating

    Heating

    Below -3 Intellige

    nt

    Defrost

    Over -

    3 Intelligent Defrost

    Outdoor coil

    Indoor unit

    Accumulator

    Adjust electronic expansion valve

    Indoor unit begins heat storage

    Reduce low temperature refrigerant

    intelligently.

    Only when the thickness gets up to a certain level will the unit begin to defrost,

    tackling problems like "frequent defrosting" or "incomplete defrosting".

  • 20 | YES Slim & YES Super

    3. Extra low temperature intelligent defrost

    When the outdoor temperature is below -3C, the outdoor humidity is very low,

    and the air conditioning is generally not easy to frost, but easy to chronically form a

    sheet of ice. After some time, this will cause ice accumulation.

    In such circumstances, the system will enable extra low temperature intelligent

    defrost mode, which can solve the problems of chronic icing and avoid frost free

    defrost.

    4. For high-humidity environments, it can run through varieddefrost cycles with

    different strengths.

    Pressure & Temperature Combined Control

    Our system has a full range of sensors including high pressure, low pressure, discharge

    temperature, heat exchanger temperature, environmental temperature, suction tem-

    perature, coil outlet temperature, and liquid pipe temperature sensors. Comprehensive

    safeguards can make the system more efficient, stable, reliable and comfortable.

    8 6 4 2 0 -2 -4 -6 -8 -10

    Chronic freezing, intelligent extra low temperature defrost

    Frosting probability

    Chronic freezing probability

    Environmental temperature

  • YES Slim & YES Super | 21

    Indoor Units

    Round-way Cassette

    Blind angles of air distribution

    Minified blind angles 360good air distribution

    Oblique view Elevation view

    Fresh air Intake

    Blind angles of air distribution

    Minified blind angles 360good air distribution

    Oblique view Elevation view

    Fresh air Intake

    Blind angles of air distribution

    Minified blind angles 360good air distribution

    Oblique view Elevation view

    Fresh air Intake

    Blind angles of air distribution

    Minified blind angles 360good air distribution

    Oblique view Elevation view

    Fresh air Intake

    360 degree circulation

    Room temperature, airflow, and noise control are

    regulated and maintained throughout the room.

    Different height setting

    Normal ceiling mode or high ceiling mode can be set

    by wired controllers to achieve effectiveness and com-

    fort ability at the same time.

    Fresh air intake

    Fresh air can be introduced directly.

    Brushless Direct Current (BLDC) fan motor

    With BLDC motor, the fan speed can be adjusted to

    reduce the noise and improve the efficiency.

    High efficiency drainage pump

    The drainage pump is available with 750mm head.

  • 22 | YES Slim & YES Super

    (Unit: mm)

    Ceiling

    Compact Ducted Indoor Unit

    Compact design

    With a height of just 200mm and depth of 450mm,

    its compact size makes installation ideal for narrow

    spaces such as corridor of bedrooms or hotel rooms.

    Flexible air return

    The air return baffle is detachable. The direction of

    air return can be adjusted during installation, either

    downward or backward.

    ESP adjustable

    The external static pressure of the ceiling-packaged

    indoor unit is adjustable, supporting different installa-

    tions and delivering optimal airflow.

    Sleep mode

    Sleep mode can be selected via a wired controller.

    Optional drainage pump

    The ceiling-packaged indoor unit fits in the narrowest

    of spaces where the drainage pump is not required.

    However, if there is enough room in the ceiling and the

    drainage distance is long, a drainage pump is available.

    700mm

    Part ceilingNarrow corridor installation

    450mm

    1.8kW~7.1kW0~30Pa

    2.0kW~5.3kW

    6.6kW~11.5kW

    14kW~17.5kW

    15~80Pa

    15~100Pa

    0~30Pa

  • YES Slim & YES Super | 23

    700mm

    Part ceilingNarrow corridor installation

    (Unit: mm)

    Ceiling

    Ceiling-packaged Duct (Low Static)

    Compact design

    With a height of just 200mm and depth of 450mm,

    its compact size makes installation ideal for narrow

    spaces such as corridor of bedrooms or hotel rooms.

    Flexible air return

    The air return baffle is detachable. The direction of

    air return can be adjusted during installation, either

    downward or backward.

    ESP adjustable

    The external static pressure of the ceiling-packaged

    indoor unit is adjustable, supporting different installa-

    tions and delivering optimal airflow.

    Sleep mode

    Sleep mode can be selected via a wired controller.

    Optional drainage pump

    The ceiling-packaged indoor unit fits in the narrowest

    of spaces where the drainage pump is not required.

    However, if there is enough room in the ceiling and the

    drainage distance is long, a drainage pump is available.

    1.8kW~5.3kW

    6.6kW~11.5kW

    14kW~17.5kW

    15~80Pa

    15~100Pa

    0~30Pa

    2.0kW~5.3kW

    6.6kW~11.5kW

    14kW~17.5kW

    15~80Pa

    15~100Pa

    0~30Pa

  • 24 | YES Slim & YES Super

    230mm

    600mm

    730~1334mm

    Fast heating

    Auxiliary electric heater is optional for the ceiling packaged indoor unit to meet consumers needs. It also speeds up the pace at which the room warms up after switching on the air-conditioner.

    Sleep mode

    Compact and quiet, the ceiling packaged indoor unit is ideal for

    locations where noise is sensitive, such as bedrooms. Sleep mode can

    be selected via a wired controller.

    Drainage pump is optional

    (Unit: mm)

    CeilingThe ceiling packaged indoor unit is extra- slim and fits in the

    narrowest of spaces where drainage pump is not required.

    However, if there is enough room in the ceiling and the drainage

    distance is long, a drainage pump is optional for selection.

    1.8kW~5.3kW

    6.6kW~11.5kW

    14kW~17.5kW

    15~80Pa

    15~100Pa

    0~30Pa

    2.0kW~5.3kW

    6.6kW~11.5kW

    14kW~17.5kW

    15~80Pa

    15~100Pa

    0~30Pa

    Floor-concealed Indoor Unit

    Medium Static Duct

    Complete product line

    Four models ranging from 2.8kW to 7.1kW are available for selection.

    Compact design

    A compact design with a uniform 230mm depth &

    600mm height is adopted for all models, and is suit-

    able for floor-concealed installations in cabinets

    ESP adjustable

    The external static pressure of the ceiling-concealed

    indoor unit is adjustable, supporting different installa-

    tions and delivering optimal airflow.

    Sleep mode

    Sleep mode can be selected via a wired controller.

    Better air distribution

    Our special 45-degree angle design for the air outlets

    helps to optimize air distribution for both cooling &

    heating.

    B

    Side air outlet

    A

    Top air outlet York air outlet

  • YES Slim & YES Super | 25

    520mm

    310mm

    840~1440mm

    Max=500mm

    Standard

    2-Way Cassette

    High Wall Indoor Unit

    Complete product line

    Seven models ranging from 2.8kW to 11.2kW are available for selection.

    Complete product line

    Five models ranging from 2.2kW to 7.1kW are available for selection. Suitable for residential & light commercial

    applications with their compact sizes and attractive design.

    Compact design

    A compact design with uniform 520mm depth and

    310mm height is adopted for all models, making in-

    stallations easier.

    Standard drainage pump

    The unit has a standard drainage pump capable of

    draining water up to 500mm, and is ideal for draining

    condensation over longer distances.

    Whole Package Design

    Electronic Expansion Valve (EEV) fitted inside the unit

    chamber makes it a package design, doing away with

    the need for external installations.

    Low noise

    High efficiency/low noise motors and fan impellers are

    adopted to enable quiet operation down to 28dB(A). In

    addition, there is a standard filter for a healthier use.

  • 26 | YES Slim & YES Super

    240mm

    680mm

    1245~1670mm

    Max=500mm

    Option

    Floor/CeilingComplete product line

    Eight models ranging from 2.8kW to 11.2kW are available for selection. Floor and

    ceiling installations are convertible for job sites.

    Compact design

    A compact design with uniform 240mm depth and

    680mm height is adopted for all models, making in-

    stallations easier.

    Optional drainage pump

    An optional drainage pump for a ceiling installation is

    available. It is capable of draining water up to 500mm,

    and is ideal for draining condensation over longer

    distances.

  • YES Slim & YES Super | 27

    Smart Control

    Gray Sky blue Green Brown

    Wired Controller

    Wireless Controller

    Group Control

    Individual Control

    Group Control

    Individual & group control

    Every indoor unit in the YES system can be controlled via the wired and wireless control-

    lers. Whats more, the wired controller has a group control function and can connect up

    to four indoor units.

    Our touch screen wired controllers come in multiple color options, and are equipped with

    TiO2 control and wireless controller receivers.

  • 28 | YES Slim & YES Super

    Central on/off control at the entrance/exit

    On/Off Controller

    Our touch screen on/off controllers can connect up to 256 indoor units or 4 VRF systems.

    It can turn on or off the indoor units within the same zone at the same time.

    Central Controller

    Our 7-inch touch screen central controller can be mounted on the wall easily. It can

    connect up to 1,024 indoor units/512 groups/128 zones/16 VRF systems, and can achieve

    the same control functions as the wired controller. In addition, it has a weekly schedule

    function.

    ON/OFF controller which can support Modbus or BACnet protocol for different application (need to choose the corresponding type of the controller).

    Central controller can support Modbus or BACnet protocol for different ap-plication (need to select the protocol mode).

    ** YDHW/YDCC can't connect to on/off controller.

    ** YDHW/YDCC cant connect to central controller.

  • YES Slim & YES Super | 29

    Pull out the door card

    Insert the door card

    Door Card

    Door Card

    Door Card

    Pull out the door card

    Insert the door card

    Door Card

    Door Card

    Door Card Function

    A door card on/off signal function is available on the YES indoor unit control board and

    features two selection modes. Users can choose one of the two functions shown below

    by using the door card and signal interface communication.

    Mode 1

    The system returns to the last operation mode automatically when the card is inserted.

    Mode 2

    The system has to be switched on manually when the card is inserted, so as to reduce

    any wastage of electricity.

  • 30 | YES Slim & YES Super

    BAS Connection

    Our YES Series can be connected to the Building Automation System for an integrated

    smart control solution.

    Metasys/Other BAS System BACnet

    communication board

    NAE Converter (JCI)

    BACne

    t

    BACnet/IP

    ** YDHW/YDCC cant connect to BAS connection.

  • YES Slim & YES Super | 31

    LOW HIGH

    Hot ambient Mild ambient Cold ambient

    Single-Connection Multi-Connection with Mixed Types

    (Fresh air & standard type indoor)Multi-Connection

    with All Fresh Air Type Indoor

    Fresh Air SystemComplete Product Line

    There are 10 models ranging from 510m3/h to 6000m3/h available and are suitable for

    residential and commercial applications.

    High ESP (External Static Pressure)

    The maximum ESP is up to 300Pa for long duct design of large space applications.

    Wide Ambient Range

    YORK Fresh Air Units can work in conditions with ambient temperatures from -7 to

    46C, capable of running all year round.

    Energy-saving Mode

    Under auto mode, fresh air units can switch to ventilation automatically at mild ambient,

    thus reducing energy consumption.

    Three Connection Types

    For all models, 1 fresh air indoor unit can be connected to 1 outdoor unit.

    For models 0510/1080 /1680/2100, multi indoor units (all fresh air type or mixed types)

    are allowed to connect to 1 outdoor unit.

  • 32 | YES Slim & YES Super

    Default2500hours

    Unlimited

    150hours

    9000hours

    1250hours

    5000hours

    Mediumpollution

    Heavypollution

    DefaultMild

    pollution

    Connection conditions:

    1. For all models: the capacity ratio of indoor units (including fresh air) must be 80%

    100% .

    2. For multi-connection with mixed types, the capacity ratio of fresh air units must be

    below 30%.

    3. For single-connection type, the outdoor model is fixed (and cannot be changed).

    Filter Cleaning Alarm

    There are six time interval options and three air pollution levels for filter cleaning alarm

    setting.

  • YES Slim & YES Super | 33

    100 0 A 1

    Y: YORK

    Condition 1: Export T1

    Design Series No.

    Design Code

    Power Supply M: 380-415V/3-50Hz E:380V/3-50Hz

    Outdoor Unit Type S:Single Unit V: Modular Unit

    Refrigerant E:R410A

    V: DC Inverter

    O: Outdoor Unit

    H: Heat Pump

    Cooling Capacity Code

    Structure H:Horizoatal Discharge V: Top Discharge

    Y:YORK

    D: Variable Refrigerant Flow(VRF) Air Conditioner

    Cooling Capacity Code in 100W

    Indoor Unit Type, CC: Medium Static Ducted

    Mode of Operation, C: Cooling Only, H: Heat Pump

    Auxiliary Electric Heater 0: No Heater, 2: With 2# Heater, 4: With 4# Heater

    Power Supply, A: 220V/1PH-50Hz

    Design Code

    Design Series Number: C Series(R410A)

    Condition, 3: Export T3

    Expansion Device, E: Internal

    Piping, L:Left, R: Rightl

    Return Plenum, F: With Back Return Plenum and Filter

    2F L E CH 3

    0 E 3

    Y:YORK

    D:Variable Refrigerant Flow(VRF) Air Conditioner

    Cooling Capacity Code in 100W Air Flow Rate (M3/h) for YDCF

    Indoor Unit Type,CD: Compact Ducted, CP: Ceiling Packaged Ducted (Low Static), CK: Round-way Ceiling Cassette,

    DK: 2-way Ceiling Cassette, EC: Floor/Ceiling, VC: Floor Conceal , HW: High Wall, CF: Fresh Air

    Mode of Operation, C: Cooling Only, H: Heat Pump

    Auxiliary Electric Heater 0: No Heater, 2: With 2# Heater, 4: With 4# Heater

    Power Supply A: 220V/1PH-50Hz, E: 380V/3PH-50Hz

    Design Code

    Design Series Number: E Series(R410A)

    Condition, 1: Export T1; 3: Export T3

    Expansion Device, N: Internal EXV No Drainage Pump, P: Interal EXV With Drainage Pump

    Outdoor Units

    E Series Indoor Units

    C Series Indoor Units

    Product Nomenclature

  • 34 | YES Slim & YES Super

    YES Slim Outdoor Unit Line-up

    Product Portfolio

    Capacity Model Cooling Capacity Heating Capacity Appearance

    8 HP YVOH080HSEM 22.4kW 25.0kW

    10HP YVOH100HSEM 28.0kW 31.5kW

    12 HP YVOH120HSEM 33.5kW 35.0kW

    Indoor

    Cooling Capacities kW

    Types 1.8 2.2 2.5 2.8 3.2 3.6 4 4.5 5 5.6

    Compact Ducted Y Y Y Y Y Y Y Y Y Y

    Low Static Duct (YDCP) Y Y Y Y Y Y Y Y Y Y

    Medium Static Ducted (YDCC)* Y Y Y Y Y

    High Wall (YDHW) Y Y Y Y

    Floor/Ceiling (YDEC) Y Y Y Y

    Floor-Concealed (YDVC) Y Y Y

    2-Way Cassette (YDDK) Y Y Y Y

    Round Way Cassette (YDCK) Y Y Y Y Y Y

    Cooling Capacities kW

    Types 6.3 7.1 8 9 10 11.2 12.5 14 17.5

    Compact Ducted Y Y

    Low Static Duct (YDCP) Y Y Y Y Y Y

    Medium Static Ducted (YDCC)* Y Y Y Y Y Y

    High Wall (YDHW) Y

    Floor/Ceiling (YDEC) Y Y Y Y

    Floor-Concealed (YDVC) Y

    2-Way Cassette (YDDK) Y Y Y

    Round Way Cassette (YDCK) Y Y Y Y Y Y Y Y

    *approximate data

  • YES Slim & YES Super | 35

    Capacity Cooling Capacity

    YVOH 080VVEE

    YVOH 100VVEE

    YVOH 120VVEE

    YVOH 140VVEE

    YVOH 160VVEE

    YVOH 180VVEE

    20HP - 2 - - - -

    22HP - 1 1 - - -

    24HP - - 2 - - -

    26HP - - 1 1 - -

    28HP - - 1 - 1 -

    30HP - - - 1 1 -

    32HP - - - - 2 -

    34HP - - - - 1 1

    36HP - - - - - 2

    38HP - - 2 1 - -

    40HP - - 2 - 1 -

    42HP - - 1 1 1 -

    44HP - - 1 - 2 -

    46HP - - - 1 2 -

    48HP - - - - 3 -

    50HP - - - - 2 1

    52HP - - - - 1 2

    54HP - - - - - 3

    Recommended Combination of Outdoor Units

    Capacity Model Cooling Capacity Heating Capacity Product

    8 HP YVOH080VVEE 25.2kW 28.0kW

    10HP YVOH100VVEE 28.0kW 31.5kW

    12 HP YVOH120VVEE 33.5kW 37.5kW

    14HP YVOH140VVEE 40.0kW 45.0kW

    16HP YVOH160VVEE 45.0kW 50.0kW

    18HP YVOH180VVEE 50.0kW 56.0kW

    YES Super Outdoor Unit Line-up

    Outdoor single modular consists of two types:

    Single-fan and double-fan models are available.

    With 2 HP increments, the outdoor unit can meet various capacity requirements.

  • 36 | YES Slim & YES Super

    YES Slim Outdoor

    Note:

    1. Cooling conditions: indoor 27CDB/ 19CWB, outdoor 35CDB, equivalent length 10m, IU/OU height difference 0m.

    2. Heating conditions: indoor 20CDB, outdoor 7CDB/6CWB, equivalent length 10m, IU/OU height difference 0m.

    3. Noise data is tested in semi-anechoic chamber and converted to equivalent anechoic chamber data. The actual noise data could vary per differ-ent installation and working conditions.

    Outdoor Unit ModelYVOH

    080HSEMYVOH

    100HSEMYVOH

    120HSEM

    HP 8HP 10HP 12HP

    Power Supply (V/Ph/Hz) 380415/3/50 380415/3/50 380415/3/50

    Capacity (kW)Cooling 22.4 28.0 33.5

    Heating 25.0 31.5 35.0

    Power (kW)Cooling 6.19 7.36 9.74

    Heating 5.71 7.34 8.75

    Compressor Output

    (kW)Nominal 4.80 6.00 7.20

    Air Flow (m3/h) - 9000 9000 10 000

    Dimensions (mm) HWD 1600 1100 400 1600 1100 400 1600 1100 400

    Weight (kg) Net Weight 180 200 200

    RefrigerantType R410A R410A R410A

    Charge (kg) 6.0 6.6 6.6

    Noise (dB(A))Anechoic Sound Level 53 56 58

    Semi-Anechoic Sound Level 56 59 61

    Piping (mm)Liquid 9.52 9.52 12.70

    Gas 19.05 22.23 25.40

    Current (A)

    Max Current 20.50 23.00 26.00

    Breaker Current 25.00 32.00 32.00

    Cooling nominal current 10.11 12.02 15.91

    Heating nominal current 9.33 11.99 14.30

    Product Specifications

  • YES Slim & YES Super | 37

    YES Super Basic

    Outdoor Unit ModelYVOH

    080VVEEYVOH

    100VVEEYVOH

    120VVEEYVOH

    140VVEEYVOH

    160VVEEYVOH

    180VVEE

    HP 8HP 10HP 12HP 14HP 16HP 18HP

    Power Supply (V/Ph/Hz) 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50

    Capacity (kW) Cooling 25.2 28.0 33.5 40.0 45.0 50.0

    Heating 28.0 31.5 37.5 45.0 50.0 56.0

    Power (kW)Cooling 6.59 7.51 9.50 10.77 11.57 15.25

    Heating 6.65 7.79 10.4 10.96 12.43 14.86

    Compressor Output

    (kW)Nominal 5.25 6.00 7.20 9.10 10.2 11.6

    Air Flow (m3/h) Cooling/Heating 10 500 10 500 10 500 17 500 17 500 17 500

    Dimensions (mm) HWD 1700 1000 760 1700 1300 760

    Weight (kg) Net Weight 210 210 225 295 310 315

    RefrigerantType R410A

    Charge (kg) 8.0 8.0 8.5 10.0 10.0 10.5

    Noise (dB(A))

    Anechoic Sound Level 57 58 59 60 60 61

    Semi-Anechoic Sound

    Level60 61 62 63 63 64

    Piping (mm)Liquid 9.52 9.52 12.7 12.7 12.7 15.88

    Gas 19.05 22.23 25.4 25.4 28.58 28.58

    Current (A)

    Max Current 17.0 19.0 23.0 28.0 31.0 33.0

    Breaker Current 25.0 25.0 32.0 40.0 40.0 50.0

    Cooling nominal current 10.6 12.0 15.2 17.2 18.4 24.1

    Heating nominal current 10.7 12.5 16.6 17.6 19.8 23.6

  • 38 | YES Slim & YES Super

    Recommended Combination Unit

    Outdoor Unit ModelYVOH100

    +YVOH100

    YVOH100 +

    YVOH120

    YVOH120 +

    YVOH120

    YVOH120 +

    YVOH140

    YVOH120 +

    YVOH160

    YVOH140 +

    YVOH160

    HP 20HP 22HP 24HP 26HP 28HP 30HP

    Power Supply (V/Ph/Hz) 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50

    Capacity (kW)Cooling 56.0 61.5 67.0 73.5 78.5 85.0

    Heating 63.0 69.0 75.0 82.5 87.5 95.0

    Power (kW)Cooling 15.02 17.01 19.00 20.27 21.07 22.34

    Heating 15.58 18.19 20.80 21.36 22.83 23.39

    Compressor Output

    (kW)Nominal 12.0 13.2 14.4 16.3 17.4 19.3

    Air Flow (m3/h) Cooling/Heating 21 000 21 000 21 000 28 000 28 000 35 000

    Dimensions (mm) HWD(1700 1000

    760) 2

    (1700 1000

    760) 2

    (1700 1000

    760) 2

    (1700 1000

    760)

    +

    (1700 1300

    760)

    (1700 1000

    760)

    +

    (1700 1300

    760)

    (1700 1000

    760)

    +

    (1700 1300

    760)

    Weight (kg) Net Weight 420 435 450 520 535 605

    RefrigerantType R410A R410A R410A R410A R410A R410A

    Charge (kg) 16.0 16.5 17.0 18.5 18.5 20

    Noise (dB(A))

    Anechoic Sound Level 61 61 62 62 62 63

    Semi-Anechoic Sound

    Level64 64 65 65 65 66

    Piping (mm)

    Liquid 15.88 15.88 15.88 19.05 19.05 19.05

    Gas 28.58 28.58 28.58 34.9 34.9 34.9

    Oil Balance 6.35 6.35 6.35 6.35 6.35 6.35

    Current (A)

    Max Current 38.0 42.0 46.0 51.0 54.0 59.0

    Breaker Current 50.0 63.0 63.0 63.0 80.0 80.0

    Cooling nominal current 24.0 27.2 30.4 32.4 33.6 35.6

    Heating nominal current 25.0 29.1 33.2 34.2 36.4 37.4

  • YES Slim & YES Super | 39

    Outdoor Unit ModelYVOH160

    + YVOH160

    YVOH160 +

    YVOH180

    YVOH180 +

    YVOH180

    YVOH120 +

    YVOH120 +

    YVOH140

    YVOH120 +

    YVOH120 +

    YVOH160

    YVOH120 +

    YVOH140 +

    YVOH160

    HP 32HP 34HP 36HP 38HP 40HP 42HP

    Power Supply (V/Ph/Hz) 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50

    Capacity (kW) Cooling 90.0 95.0 100.0 107.0 112.0 118.5

    Heating 100.0 106.0 112.0 120.0 125.0 132.5

    Power (kW)Cooling 23.14 26.82 30.50 29.77 30.57 31.84

    Heating 24.86 27.29 29.72 31.76 33.23 33.79

    Compressor Output (kW) Nominal 20.4 21.8 23.2 23.5 24.6 26.5

    Air Flow (m3/h) Cooling/Heating 35 000 35 000 35 000 38 500 38 500 45 500

    Dimensions (mm) HWD(1700 1300

    760) 2

    (1700 1300

    760) 2

    (1700 1300

    760) 2

    (1700 1000

    760) 2

    +

    (1700 1300

    760)

    (1700 1000

    760)

    2 +

    (1700 1300

    760)

    (1700 1000

    760)

    + 2

    (1700 1300

    760)

    Weight (kg) Net Weight 620 625 630 745 760 830

    RefrigerantType R410A R410A R410A R410A R410A R410A

    Charge (kg) 20.0 20.5 21.0 27.0 27.0 28.5

    Noise (dB(A))

    Anechoic Sound Level 63 63 64 64 64 64

    Semi-Anechoic Sound

    Level66 66 67 67 67 67

    Piping (mm)

    Liquid 19.05 19.05 19.05 19.05 19.05 19.05

    Gas 34.9 34.9 38.1 38.1 38.1 38.1

    Oil Balance 6.35 6.35 6.35 6.35 6.35 6.35

    Current (A)

    Max Current 62.0 64.0 66.0 74.0 77.0 82.0

    Breaker Current 80.0 80.0 100.0 100 100 100

    Cooling nominal current 36.8 42.5 48.2 47.6 48.8 50.8

    Heating nominal current 39.6 43.4 47.2 50.8 53.0 54.0

    Recommended Combination Unit

  • 40 | YES Slim & YES Super

    Outdoor Unit Model

    YVOH120 +

    YVOH160 +

    YVOH160

    YVOH140 +

    YVOH160 +

    YVOH160

    YVOH160 +

    YVOH160 +

    YVOH160

    YVOH160 +

    YVOH160 +

    YVOH180

    YVOH160 +

    YVOH180 +

    YVOH180

    YVOH180 +

    YVOH180 +

    YVOH180

    HP 44HP 46HP 48HP 50HP 52HP 54HP

    Power Supply (V/Ph/Hz) 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50

    Capacity (kW)Cooling 123.5 130.0 135.0 140.0 145.0 150.0

    Heating 137.5 145.0 150.0 156.0 162.0 168.0

    Power (kW)Cooling 32.64 33.91 34.71 38.39 42.07 45.75

    Heating 35.26 35.82 37.29 39.72 42.15 44.58

    Compressor Output

    (kW)Nominal 27.6 29.5 30.6 32.0 33.4 34.8

    Air Flow (m3/h) Cooling/Heating 45 500 52 500 52 500 52 500 52 500 52 500

    Dimensions (mm) HWD

    (1700 1000

    760)

    +

    2 (1700

    1300 760)

    (1700 1300

    760)

    3

    (1700 1300

    760)

    3

    (1700 1300

    760)

    3

    (1700 1300

    760)

    3

    (1700 1300

    760)

    3

    Weight (kg) Net Weight 845 915 930 935 940 945

    RefrigerantType R410A R410A R410A R410A R410A R410A

    Charge (kg) 28.5 30.0 30.0 30.5 31.0 31.5

    Noise (dB(A))

    Anechoic Sound Level 64 65 65 65 65 66

    Semi-Anechoic Sound

    Level67 68 68 68 68 69

    Piping (mm)

    Liquid 19.05 19.05 19.05 19.05 19.05 19.05

    Gas 38.1 38.1 38.1 38.1 38.1 38.1

    Oil Balance 6.35 6.35 6.35 6.35 6.35 6.35

    Current (A)

    Max Current 85.0 90.0 93.0 95.0 97.0 99.0

    Breaker Current 100 125.0 125.0 125.0 125.0 125.0

    Cooling nominal current 52.0 54.0 55.2 60.9 66.6 72.3

    Heating nominal current 56.2 57.2 59.4 63.2 67.0 70.8

    Note:

    1. Cooling conditions: indoor 27CDB/ 19CWB, outdoor 35CDB, equivalent length 10m, IU/OU height difference 0m.

    2. Heating conditions: indoor 20CDB, outdoor 7CDB/6CWB, equivalent length 10m, IU/OU height difference 0m.

    3. Noise data is tested in semi-anechoic chamber and converted to equivalent anechoic chamber data. The actual noise data could vary per differ-ent installation and working conditions.

    4. For combined models, clrcult breaker should be installed for not only the main power supply, but also the power supply of each module.

  • YES Slim & YES Super | 41

    Compact Ducted Indoor Unit

    Indoor Unit ModelYDCD018H0NA

    YDCD022

    H0NA

    YDCD025H0NA

    YDCD028H0NA

    YDCD032

    H0NA

    YDCD036H0NA

    Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50

    Capacity (kW)

    Cooling 1.8 2.2 2.5 2.8 3.2 3.6

    Heating 2.2 2.5 2.8 3.2 3.6 4.0

    Power Input (W) 37 37 46 46 48 50

    Current (A) Nominal 0.16 0.16 0.2 0.2 0.21 0.22

    Air Flow (m3/h) - 350 350 450 450 480 480

    ESP (Pa)Standard

    (min-max)0(0-30) 0(0-30) 0(0-30) 0(0-30) 0(0-30) 0(0-30)

    Dimensions (mm) HWD 200X700X450200X700X450

    200X700X450

    200X700X450

    200X700X450

    200X700X450

    Weight (kg) Net Weight 23 23 23 23 23 25

    Noise (dB(A)) H/M/L 29/25/23 29/25/23 31/27/25 31/27/25 32/29/27 32/29/27

    Piping (mm)

    Liquid/Gas 6.35/9.52 6.35/9.52 6.35/9.52 6.35/9.52 6.35/12.70 6.35/12.70

    Drainage DN25 DN25 DN25 DN25 DN25 DN25

    Indoor Unit ModelYDCD040H0NA

    YDCD045H0NA

    YDCD050H0NA

    YDCD056H0NA

    YDCD063H0NA

    YDCD071

    H0NA

    Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50

    Capacity (kW)

    Cooling 4.0 4.5 5.0 5.6 6.3 7.1

    Heating 4.5 5.0 5.6 6.3 7.1 8.0

    Power Input (W) 70 70 76 106 106 110

    Current (A) Nominal 0.3 0.3 0.33 0.46 0.48 0.48

    Air Flow (m3/h) - 560 560 750 900 900 990

    ESP (Pa)Standard

    (min-max)0(0-30) 0(0-30) 0(0-30) 0(0-30) 0(0-30) 0(0-30)

    Dimensions (mm) HWD 200X700X450200X900X450

    200X900X450

    200X900X450

    200X1100X450

    200X1100X450

    Weight (kg) Net Weight 25 30 34 34 34 34

    Noise (dB(A)) H/M/L 38/35/32 35/32/29 35/32/29 39/36/32 37/34/31 37/35/32

    Piping (mm)

    Liquid/Gas 6.35/12.70 6.35/12.70 6.35/12.70 6.35/12.70 9.52/15.88 9.52/15.88

    Drainage DN25 DN25 DN25 DN25 DN25 DN25

  • 42 | YES Slim & YES Super

    Indoor Unit ModelYDCP

    036H0NAYDCP

    040H0NAYDCP

    045H0NAYDCP

    050H0NAYDCP

    056H0NAYDCP

    063H0NA

    Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50

    Capacity (kW)Cooling 3.6 4.0 4.5 5.0 5.6 6.3

    Heating 4.0 4.5 5.0 5.6 6.3 7.1

    Power Input (W) 50 70 70 76 106 106

    Current (A) Nominal 0.22 0.3 0.3 0.33 0.46 0.48

    Air Flow (m3/h) Cooling/Heating 480 560 560 750 900 900

    ESP (Pa)Standard (min

    max)0 (030) 0 (030) 0 (030) 0 (030) 0 (030) 0 (030)

    Dimensions (mm) HWD 200 700 620 200900620 2001100620

    Weight (kg) Net Weight 25 25 25 30 34 34

    Noise (dB(A)) H/M/L 30/27/25 35/32/29 35/32/29 33/31/28 37/34/30 35/33/29

    Piping (mm)Liquid/Gas 6.35/12.7 6.35/12.7 6.35/12.7 6.35/12.7 6.35/12.7 9.52/15.88

    Drainage DN25

    Indoor Unit Model YDCP071H0NA YDCP080H0NA YDCP090H0NA YDCP100H0NA YDCP112H0NA

    Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50

    Capacity (kW)Cooling 7.1 8.0 9.0 10.0 11.2

    Heating 8.0 9.0 10.0 11.2 12.5

    Power Input (W) 110 138 206 260 260

    Current (A) Nominal 0.48 0.60 0.90 1.25 1.25

    Air Flow (m3/h) Cooling/Heating 990 1200 1500 1700 1700

    ESP (Pa)Standard (min

    max)0 (030) 15 (040) 15 (040) 15 (040) 15 (040)

    Dimensions (mm) HWD 2001100620 2001100620 220 1450 620

    Weight (kg) Net Weight 34 34 48 48 48

    Noise (dB(A)) H/M/L 36/33/30 39/36/31 39/36/31 41/37/33 41/37/33

    Piping (mm)Liquid/Gas 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88

    Drainage DN25

    Indoor Unit Model YDCP018H0NA YDCP022H0NA YDCP025H0NA YDCP028H0NA YDCP032H0NA

    Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50

    Capacity (kW)Cooling 1.8 2.2 2.5 2.8 3.2

    Heating 2.2 2.5 2.8 3.2 3.6

    Power Input (W) 37 37 46 46 48

    Current (A) Nominal 0.16 0.16 0.20 0.20 0.21

    Air Flow (m3/h) Cooling/Heating 350 350 450 450 480

    ESP (Pa)Standard (min

    max)0 (030) 0 (030) 0 (030) 0 (030) 0 (030)

    Dimensions (mm) HWD 200 700 620 200 700 620 200 700 620 200 700 620 200 700 620

    Weight (kg) Net Weight 23 23 23 23 23

    Noise (dB(A)) H/M/L 27/25/23 27/25/23 28/26/24 28/26/24 30/27/25

    Piping (mm)Liquid/Gas 6.35/9.52 6.35/9.52 6.35/9.52 6.35/9.52 6.35/12.7

    Drainage DN25

    Ceiling Packaged Duct (Low Static)

  • YES Slim & YES Super | 43

    Medium Static Duct

    Indoor Unit ModelYDCC

    020H0FLEAYDCC

    025H0FLEAYDCC

    034H0FLEAYDCC

    045H0FLEAYDCC

    053H0FLEAYDCC

    066H0FLEA

    Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50

    Capacity (kW)Cooling 2.0 2.5 3.4 4.5 5.3 6.6

    Heating 2.2 3.0 3.9 4.95 5.8 6.8

    Power Input (W) 40 55 75 100 110 185

    Current (A) Nominal 0.35 0.35 0.40 0.46 0.52 0.96

    Air Flow (m3/h) Standard 380 450 600 800 930 1200

    ESP (Pa)Standard (min

    max)15 (0/15/30) 15 (0/15/30) 15 (0/15/30) 15 (0/15/30) 15 (0/15/30) 15 (15/40/80)

    Dimensions (mm) HWD 226 855 602 226 855 602226 1055

    602

    226 1175

    602

    226 1175

    602

    245 1475

    576

    Weight (kg) Net Weight 20 20 23 25 25 32

    Piping (mm) Liquid/Gas 6.35/9.52 6.35/9.52 6.35/12.7 6.35/12.7 6.35/12.7 9.52/15.88

    Drainage Piping (mm) DN25

    Indoor Unit ModelYDCC

    078H0FLEAYDCC

    095H0FLEAYDCC

    115H0FLEAYDCC

    140H0FLEAYDCC

    175H0FLEA

    Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50

    Capacity (kW)Cooling 7.8 9.5 11.5 14.0 17.5

    Heating 8.2 11.0 13.0 16.5 19.0

    Power Input (W) 215 270 300 420 510

    Current (A) Nominal 1.08 1.29 1.30 1.90 2.11

    Air Flow (m3/h) Standard 1360 1600 1900 2200 2700

    ESP (Pa)Standard (min

    max)15 (15/40/80) 15 (15/40/80) 15 (15/40/80) 15 (15/50/100) 15 (15/50/100)

    Dimensions (mm) HWD 245 1475 576 245 1805 576 245 1805 576 430 1563 655 430 1563 655

    Weight (kg) Net Weight 33 41 41 58 65

    Piping (mm) Liquid/Gas 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88

    Drainage Piping (mm) DN25

  • 44 | YES Slim & YES Super

    Round-way Cassette

    Indoor Unit ModelYDCK

    028H0PAYDCK

    036H0PAYDCK

    040H0PAYDCK

    045H0PAYDCK

    050H0PAYDCK

    056H0PAYDCK

    063H0PA

    Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50

    Capacity (kW)Cooling 2.8 3.6 4.0 4.5 5.0 5.6 6.3

    Heating 3.2 4.0 4.5 5.0 5.6 6.3 7.1

    Power Input (W) 17 19 19 19 26 27 42

    Current (A) Nominal 0.13 0.15 0.15 0.15 0.22 0.28 0.37

    Air Flow (m3/h) Standard 780 810 810 810 900 960 1100

    Dimensions (mm)

    Unit (HWD)246 840

    840

    246 840

    840

    246 840

    840

    246 840

    840

    246 840

    840

    246 840

    840

    246 840

    840

    Panel (HWD)50 950

    950

    50 950

    950

    50 950

    950

    50 950

    950

    50 950

    950

    50 950

    950

    50 950

    950

    Weight (kg)Unit 23 23 23 23 26 26 26

    Panel 5.5 5.5 5.5 5.5 5.5 5.5 5.5

    Noise (dB(A)) H/M/L 28/27/25 29/28/26 29/28/26 29/28/26 31/29/27 32/31/28 32/31/28

    Piping (mm)Liquid/Gas 6.35/9.52 6.35/12.7 6.35/12.7 6.35/12.7 6.35/12.7 6.35/12.7 9.52/15.88

    Drainage DN25

    Indoor Unit ModelYDCK

    071H0PAYDCK

    080H0PAYDCK

    090H0PAYDCK

    100H0PAYDCK

    112H0PAYDCK

    125H0PAYDCK

    140H0PA

    Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50

    Capacity (kW)

    Cooling 7.1 8.0 9.0 10.0 11.2 12.5 14.0

    Heating 8.0 9.0 10.0 11.2 12.5 14.0 16.0

    Power Input (W) 42 63 63 129 129 142 171

    Current (A) Nominal 0.37 0.54 0.54 1.07 1.07 1.17 1.39

    Air Flow (m3/h) Standard 1100 1500 1500 1900 1900 2010 2010

    Dimensions (mm)

    Unit (HWD)246 840

    840

    288 840

    840

    288 840

    840

    288 840

    840

    288 840

    840

    288 840

    840

    288 840

    840

    Panel (HWD)50 950

    950

    50 950

    950

    50 950

    950

    50 950

    950

    50 950

    950

    50 950

    950

    50 950

    950

    Weight (kg)

    Unit 26 29 29 29 29 29 32

    Panel 5.5 5.5 5.5 5.5 5.5 5.5 5.5

    Noise (dB(A)) H/M/L 35/31/28 38/35/32 38/35/32 45/39/36 45/39/36 47/43/38 48/45/42

    Piping (mm)

    Liquid/Gas 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88

    Drainage DN25

  • YES Slim & YES Super | 45

    High Wall

    Indoor Unit ModelYDHW

    022H0NAYDHW

    028H0NAYDHW

    036H0NAYDHW

    056H0NAYDHW

    071H0NA

    Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50

    Capacity (kW)Cooling 2.2 2.8 3.6 5.6 7.1

    Heating 2.8 3.2 4.0 6.3 7.15

    Power Input (W) 35 35 40 50 70

    Current (A) Nominal 0.18 0.18 0.23 0.25 0.35

    Air Flow (m3/h) Standard 450 450 570 730 1050

    Dimensions (mm) HWD 295 890 215 295 890 215 295 890 215 302 1070 220 302 1070 220

    Weight (kg) Net Weight 14 14 14 16 16

    Noise (dB(A)) H/M/L 34/30/26 34/30/26 38/35/31 44/41/39 44/41/39

    Piping (mm)Liquid/Gas 6.35/9.52 6.35/9.52 6.35/12.7 6.35/12.7 9.52/15.88

    Drainage DN20

    2-way Cassette

    Indoor Unit ModelYDDK

    028H0PAYDDK

    036H0PAYDDK

    045H0PAYDDK

    056H0PAYDDK

    071H0PAYDDK

    090H0PAYDDK

    112H0PA

    Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50

    Capacity (kW)Cooling 2.8 3.6 4.5 5.6 7.1 9.0 11.2

    Heating 3.2 4.0 5.0 6.3 8.0 10.0 12.5

    Power Input (W) 60 62 68 85 94 129 175

    Current (A) Nominal 0.27 0.28 0.31 0.39 0.43 0.59 0.80

    Air Flow (m3/h) Standard 500 600 770 900 1160 1500 1700

    Dimensions (mm)

    Unit (HWD)310 840

    520

    310 840

    520

    310 960

    520

    310 960

    520

    310 1200

    520

    310 1440

    520

    310 1440

    520

    Panel (HWD)30 1083

    630

    30 1083

    630

    30 1203

    630

    30 1203

    630

    30 1443

    630

    30 1683

    630

    30 1683

    630

    Weight (kg)Unit 41 41 47 47 53 65 65

    Panel 6 6 7 7 8 9 9

    Noise (dB(A)) H/M/L 34/28/22 35/32/27 38/33/28 40/36/34 42/38/35 42/38/35 46/43/38

    Piping (mm)Liquid/Gas 6.35/9.52 6.35/12.7 6.35/12.7 6.35/12.7 9.52/15.88 9.52/15.88 9.52/15.88

    Drainage DN25

  • 46 | YES Slim & YES Super

    Floor-concealed

    Indoor Unit ModelYDVC

    028H0NAYDVC

    045H0NAYDVC

    056H0NAYDVC

    071H0NA

    Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50

    Capacity (kW)Cooling 2.8 4.5 5.6 7.1

    Heating 3.2 5.0 6.3 8.0

    Power Input (W) 41 50 60 71

    Current (A) Nominal 0.18 0.23 0.27 0.32

    Air Flow (m3/h) Standard 420 680 900 1000

    Dimensions (mm) HWD 600 730 230 600 980 230 600 1334 230 600 1334 230

    Weight (kg) Net Weight 20 24 30 31

    Noise (dB(A)) H/M/L 35/32/30 35/32/30 36/33/31 37/34/32

    Piping (mm)Liquid/Gas 6.35/9.52 6.35/12.7 6.35/12.7 9.52/15.88

    Drainage DN25

    Floor/Ceiling

    Indoor Unit ModelYDEC

    028H0NAYDEC

    036H0NAYDEC

    045H0NAYDEC

    056H0NAYDEC

    071H0NAYDEC

    080H0NAYDEC

    090H0NAYDEC

    112H0NA

    Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50

    Capacity (kW)Cooling 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2

    Heating 3.2 4.0 5.0 6.3 8.0 9.0 10.0 12.5

    Power Input (W) 110 110 130 130 180 210 210 210

    Current (A) Nominal 0.55 0.55 0.65 0.65 0.83 0.97 0.97 1.20

    Air Flow (m3/h) Standard 600 600 950 950 1250 1550 1550 1950

    Dimensions

    (mm)HWD

    680 1245

    240

    680 1245

    240

    680 1245

    240

    680 1245

    240

    680 1245

    240

    680 1245

    240

    680 1245

    240

    680 1670

    240

    Weight (kg)Net

    Weight36 36 36 36 36 38 38 51

    Noise (dB(A)) H/M/L 37/33/30 37/33/30 46/44/41 46/44/42 47/45/42 52/48/46 52/48/46 52/48/46

    Piping (mm)Liquid/Gas 6.35/9.52 6.35/12.7 6.35/12.7 6.35/12.7 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88

    Drainage DN25

    Note:

    1. Cooling conditions: indoor 27CDB/ 19CWB, outdoor 35CDB, equivalent length 10m, IU/OU height difference 0m.

    2. Heating conditions: indoor 20CDB, outdoor 7CDB/6CWB, equivalent length 10m, IU/OU height difference 0m.

    3. Noise data is tested in semi-anechoic chamber and converted to equivalent anechoic chamber data. The actual noise data could vary per dif-ferent installation and working conditions.

  • YES Slim & YES Super | 47

    Fresh Air Indoor

    Indoor Unit ModelYDCF0510H0NA

    YDCF1080H0NA

    YDCF1680H0NA

    YDCF2100H0NA

    YDCF2500H0NA

    Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 380/3/50

    Capacity (kW)

    Cooling 7.1 14.0 22.4 28.0 28.0

    Heating 3.5 7.5 10.0 12.0 14.0

    Heating* 4.4 9.3 12.8 15.4 18.2

    Power Input (W) 110 250 390 530 740

    Current (A) Nominal 0.5 1.1 1.9 2.3 2.0

    Air Flow (m3/h) Standard 510 1080 1680 2100 2500

    ESP (Pa) Standard/High 50/100 100/200 150/220 150/220 150/200/300

    Dimensions (mm) HWD 1105 650 220 820 850 480 1406 850 480 1406 850 480 1406 850 508

    Weight (kg) Net Weight 34 70 110 110 110

    Noise (dB(A)) Standard/High 34/40 36/41 43/46 44/47 40/50/51

    PipingLiquid/Gas (mm) 9.52/15.88 9.52/15.88 9.52/22.23 9.52/22.23 9.52/22.23

    Drainage (mm) DN25 DN25 DN32 DN32 DN32

    Connect to YES outdoor unit (HP) 854 854 854 1054 10

    Indoor Unit ModelYDCF3000

    H0NEYDCF3500H0NE

    YDCF4000H0NE

    YDCF5000H0NE

    YDCF6000H0NE

    Power Supply (V/Ph/Hz) 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50

    Capacity (kW)

    Cooling 28.0 40.0 45.0 56.0 56.0

    Heating 16.0 20.0 21.0 26.0 32.0

    Heating* 21.0 26.3 27.6 34.1 42.0

    Power Input (W) 1050 950 1260 1580 2310

    Current (A) Nominal 2.3 2.5 2.7 3.6 4.3

    Air Flow (m3/h) Standard 3000 3500 4000 5000 6000

    ESP (Pa) Standard/High 200/300 200/300 200/300 200/300 200/300

    Dimensions (mm) HWD 1406 850 508 1680 850 670 1680 850 670 2000 850 670 2000 850 670

    Weight (kg) Net Weight 110 170 170 210 210

    Noise (dB(A)) Standard/High 51/54 51/54 53/55 54/56 56/57

    PipingLiquid/Gas (mm) 9.52/22.23 12.7/25.4 12.7/28.6 15.88/28.6 15.88/28.6

    Drainage (mm) DN32 DN40

    Connect to YES outdoor unit (HP) 10 14 16 20 20

    Note:1. Cooling capacity is based on ambient temperature 33C DB, 28C WB.2. Heating capacity is based on ambient temperature 7C DB, 6C WB; model with open * mark is based on ambient temperature 0C DB, -3C

    WB; 3. Cooling default temperature is set as 18C, heating default temperature is set as 25C (0510-2100) or 22C (2500-6000); 4. Outdoor ambient temperature range is -7C46C DB;5. Models below 2100m3/h can adopt mixed connection with indoor units, but the capacity of fresh air unit cannot be over 30% of the outdoor

    capacity;6. Models below 2100m3/h can adopt multiple connections to YES outdoor unit (all fresh air system), but the capacity ratio should be between

    80%100%;7. Models over 2500m3/h cannot use multi-connection and mixed connection type. They can only use one-to-one connection to the outdoor unit.

  • 48 | YES Slim & YES Super

    Notes

  • Notes

  • PUBL-6969 2013 Johnson Controls, Inc. www.johnsoncontrols.com