VRF- II SERIES

Page 2: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

2

WHAT IS VRF-II SERIES ?

VRF - II Series

Outdoor unit Indoor unit Controller

J-II Series

VR-II Series

Mini

VRF

VRF

HEAT

PUMP

VRF

HEAT RECOVERY

V-II Series

Page 3: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

3

WHAT IS VRF-II SERIES ?

R410A Inverter Modular

High

COP’s

Flexible

Design High

Reliability

Easy

Installation

wide

LineUp

High

Diversity

New

Control

System

Easy

Mainte

-nance

Page 4: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE 4

Line up

4

・Outdoor units

・Indoor units

・Controllers

・Options

Page 5: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

- 3 models from 4 – 6 HP (11.2 – 15.5 kW) - fully compatible with V-II & VR-II Series

5

LINEUP

4 / 5 / 6 HP

3 models

Series

OUT

DOOR

UNITS

W : 970 mm

H : 1.334 mm

D : 370 mm

Mini

VRF

Page 6: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE 6

Target image

Apartment

House

Small office

Shop

Page 7: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE 7

Line-up

■Outdoor unit

5 4 6

Capacity

(kW)

Power source

Heating

Cooling

Capacity range (HP)

Dimensions

(H×W×D) (mm)

14.0 11.2 15.5

16.0 12.5 18.0

1,340 × 970 × 370

Φ1, 220~240V, 50Hz

3 models lineup (4HP, 5HP, 6HP)

Weight (kg) 122

Page 8: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE 8

Comparison with competitor

Top-class high EER/COP

4HP class

5HP class

6HP class

EER

COP

EER

COP

EER

COP

FGL D M

4.00

4.53

3.60

4.20

3.45

3.95

3.99

4.56

3.99

4.15

3.42

3.94

3.35

3.42

3.24

3.70

2.90

3.23

High Energy Saving

No.1!

Page 9: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

- 5 models from 8 – 16 HP (22.4 – 45.0 kW) - Same range for V-II & VR-II Series

9

LINEUP

8HP 10HP

14HP

12HP

16HP

5 models

Series

VRF

HEAT RECOVERY

OUT

DOOR

UNITS

W : 930 mm

W : 1260 mm

VRF

HEAT

PUMP

Page 10: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

10

8/10/12HP

14/16HP

18/20/22/24HP

26/28HP

30/32HP

34/36HP

38/40HP

42/44HP

46/48HP

- 21 system models, 8HP to 48HP (22.4 – 134.4kW) - Up to 3 outdoor units combination possible.

LINEUP

VRF

HEAT RECOVERY

OUT

DOOR

UNITS

VRF

HEAT

PUMP

Page 11: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Outdoor unit combinations

34 system models, 8HP to 48HP in 2HP increment

Rated Capacity 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48

Outdoor Unit 1 8 10 12 14 16 10 10 12 12 16 16 16 16 12 12 16 16 16 16 16 16

Outdoor Unit 2 8 10 10 12 10 12 14 16 12 12 12 12 16 16 16 16

Outdoor Unit 3 10 12 10 12 10 12 14 16

Space

Saving

Rated Capacity 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48

Outdoor Unit 1 8 14 8 10 10 10 14 14 14 14 16 14 16

Outdoor Unit 2 8 8 8 8 10 10 10 10 14 14 14 14 14

Outdoor Unit 3 8 8 8 10 8 10 8 10 10 14 14

24/26/28/30HP 32/34HP 8HP 22HP 36/38/40HP 42/44HP

8/10/12HP 14/16HP 18/20/22/24HP 26/28HP 30/32HP

34/36/HP 38/40HP 42/44HP 46/48HP

Energy

Efficiency

11

Page 12: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

12

24HP

Space saving

( AJY216GALH )

Outdoor Units

12% Energy saving

Choice of combination

Energy Efficiency

( AJY216GALHH)

COP

(Ave.)

12HP 12HP 8HP 8HP 8HP

4.22 3.76

Space (Footprint)

1.438 m2 2.165 m2

33% Space saving

Page 13: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE 13

LINEUP

Compact

Cassette

Cassette Compact

Duct

Slim

Duct

Low

Static

Duct

Duct High

Static

Duct

Floor/

Ceiling

Ceiling Compact

Wall

Mounted

Compact

wall

Mounted

Wall

Mounted

2.2

2.8

3.6

4.5

5.6

7.1

9.0

11.2

12.5

14.0

18.0

22.4

25.0

VRF

HEAT RECOVERY

- 12 types 55 models from 2.2 – 25.0 kW) - Same range for J-II, V-II & VR-II Series

IN

DOOR

UNITS

13

Mini

VRF

VRF

HEAT

PUMP

Page 14: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

LINEUP

OOOOOOLALH OOOOOOGALH

Connectable

Outdoor Unit

MODEL

CHANGE

UPGRADED

Operation control adoption to Heat Recovery

RB unit connection

COMPATIBILITY - New indoor units available for both HP &HR model. - Current indoor units are just valid for HP model.

IN

DOOR

UNITS

Model

Name

Current model NEW model

Page 15: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Optional Parts

15

Page 16: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

- All controllers available for HR&HP - New touch panel wired RC release

16

Individual control

Wireless Remote

Controller Simple Remote Controller Wired Remote Controller

Group Remote

Controller Central Remote

Controller

Touch Panel

Controller

System Controller

with / without

operation mode button

Max. Controllable 8 groups of indoor units

Max. Controllable

100 indoor units

Max. Controllable

400 indoor units

Max. Controllable

1600 indoor units

Central control

NEW

LINEUP

OPTION VRF

HEAT RECOVERY

Mini

VRF

VRF

HEAT

PUMP

Page 17: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Option line up

Software updates will be released for Service Tool & Web Monitoring Tool

to correspond to new Heat Recovery System

Signal Amplifier will be updated to correspond to new Heat Recovery System

Network Converter is adopted to our new “G”-Type RAC/PAC units

17

Service & Maintenance

Service Tool

UTY-ASGX

Ver. 0.1.4.0

Web Monitoring Tool

UTY-AMGX

Ver. 0.1.4.0

Converter / Amplifier

Network Convertor

UTY-VGGXZ1

NEW

Signal Amplifier

UTY-VSGXZ1

NEW

LINEUP

Page 18: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

RB units Branch pipe

(Outdoor Units)

)

Branch pipes (Indoor Units) Header

Option line up

NEW

UTP-RX01BH UTP-RX04BH UTP-DX567A

UTR-H0906L

UTR-H1806L

UTR-H0908L

UTR-H1808L

UTP-J0908A

UTP-J1808A

UTR-BP090X UTR-BP180X UTR-BP567X

UTP-BX090A UTP-BX180A UTP-BX567A

New Piping Options are available (only) for

Suction Gas Pipe

Discharge Gas Pipe

Liquid Pipe

Suction Gas Pipe

Discharge Gas Pipe

Liquid Pipe

UTP-J0906A

UTP-J1806A

NEW

NEW NEW NEW NEW NEW

NEW

UTP-RX01CH

NEW

UTP-RX01AH

NEW

18

Discharge Gas Pipe Suction Gas Pipe Liquid Pipe

Suction Gas Pipe

Discharge Gas Pipe

Liquid Pipe

Suction Gas Pipe

Discharge Gas Pipe

Liquid Pipe

Suction Gas Pipe

Discharge Gas Pipe

Liquid Pipe

LINEUP

Page 19: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

19

OPTIONS

Others

UTG-UFYC-W

Air Outlet Shutter Plate

UTG-AGYA-W

UTG-BGYA-W UTR-YDZD

UTR-YDZE

UTZ-VXAA

UTZ-VXGA

Grille Kit

For Compact Cassette type

Wide Panel

Panel Spacer

For Cassette type

For Compact Cassette

type

For all Cassette types

UTG-UFGC-W

UTG-UGYA-W

UTG-UGGA-W

Fresh Air Kit

For Cassette type For Cassette type

For Cassette type

Page 20: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

20

OPTIONS

Others

UTD-RF204

Flange (Square)

Drain Pump Unit

UTD-SF045T UTD-LF25NA

UTD-LF60KA UTZ-PX1BBA

UTZ-PX1NBA

UTR-DPB24T

Flange (Round)

For Low Static Pressure Duct type/ Duct type For Low Static Pressure Duct type/ Duct type For Low Static Pressure Duct type/ Duct type

Long Life Filter

Long Life Filter Drain Pump Unit

For Low Static

Pressure Duct type

/ Duct type

For Compact Duct

type

For Compact Duct

type

For High Static Pressure Duct type For Ceiling type

OPTIONS

Page 21: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

21

OPTIONS

Others

UTB-YWB UTD-RS100

UTR-EV09XB

UTR-EV14XB

Please refer the Parts Number shown in D&T

IR Receiver Unit

For all duct type

Remote Sensor Kit

EV Kit

UTY-LRHYB1

UTY-LRHGB1

For Cassette type

For Compact Wall Mounted type

External Input & Output

IR Receiver Kit

OPTIONS

Page 22: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

22

OPTIONS

Energy Recovery Ventilator

350 m3/h 250 m3/h 500 m3/h 800 m3/h 1,000 m3/h

UTZ-BX025A UTZ-BX035A UTZ-BX050A UTZ-BX080A UTZ-BD100A

270 / 599 / 882

Dimension <H x W x D mm>

270 / 804 / 882 270 / 904 /962 388 / 884 /1250 388 / 884 /1250

Weight <kg>

Noise Level < Ex-H / H/ L>

28 / 26 / 21 32 / 29 / 25 34 / 31 / 25 38 / 36.5 / 32 37.5 / 36 / 31

29 37 43 71 71

OPTIONS

Page 23: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

High Energy Efficiency

23

Page 24: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Series VR-II VII

8/10HP

12HP

14/16HP

Brand Fujitsu brand Sanyo brand

New DC Twin Rotary Inverter Compressor

each VR-II OU just using one new inverter compressor

24

DC Twin Rotary

(60cc)

DC Twin Rotary

(60cc)

AC Scroll

(66.7cc)

Constant Inverter

Inverter

All DC Inverter

All DC Inverter

New DC Twin Rotary

(65cc)

New DC Twin Rotary

(79cc)

Inverter

Inverter

All DC Inverter

Compressor technology

Page 25: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

New Compressor with improved rotation control New Rotation Control with 0.1 Hz increment

V-II Series

1Hz

71 step

(30Hz to 100Hz)

Inverter Frequency

Ca

pa

cit

y

25

VR-II Series

0.1Hz

1001step

(20Hz to 120Hz)

Inverter Frequency

Ca

pa

cit

y

8-12HP : 42W

14-16HP : 56W

→ Little room temperature variation provides comfort with little energy

loss.

Page 26: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE 26

More Comfort & Convenience

26

Page 27: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

27

Convenient functions added

Easy – to - Operate

Comes with energy saving functions

Improved operation response

New wired remote controller (touch screen)

Large Touch Panel

7 language correspondence

EN, DE, FR, PO, ES, RU, CH

Room temperature set point limitation

Anti-cool and anti-heat setting

etc…

Background light

Room temperature display

etc…

40% reduction in time

(until responding indoor unit.)

New wired Touch Screen RC

Page 28: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

28

The new remote controller use the non-polar 2-wire method.

Previous remote controllers can be used, but the functions available in the new remote controller cannot be used.

UTY-RNR* UTY-RNH* UTY-RSK* UTY-RHK*

The polar 3-wire method.

Mixed installation

not allowed

Easy Installation of Remote Control Cable

New Wired Remote Controller can be connected

NEW

<New Wired R.C.> <Current Wired R.C.> <Simple R.C.>

<New I.U.>

Non-polar 2-wire method

Page 29: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Auto changeover VR-II

29

Set :18 ℃

Room :18℃

Auto(Cool) Set :26 ℃

Room :24℃

Auto(Heat)

Set :26 ℃

Room :27℃

Auto (Fan)

Set :22℃

Room :23℃

Auto (Cool)

When set to Auto, Cooling/Heating mode is automatically changed in accordance with set

temperature and room temperature.

Automatic Cooling/Heating changeover is possible

for each Indoor unit

Page 30: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

User Friendly Control System

30

Page 31: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE 31

New Central Remote Controller

Automatic display of number of connected indoor unit

Max. Number of

display

Number of connected indoor unit

0~9

10~20

21~40 41~80

81~100

9 20

40 80

100

Connected indoor unit

Max. controllable 100 indoor units

User Friendly Control System

Page 32: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

32

・Automatic or manual indoor unit registration

・Interlock with external device

Indoor unit registration

start

Indoor unit registration

finish

Indoor unit registration

User Friendly Control System

Page 33: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

33

・Day & Time setting (Summer time, Automatic system clock adjustment)

・Room temperature set point upper and lower limitation

Original Set

Temp Range

Heating Set

Temp Range

Cooling Set

Temp Range

The time setting of each controller can be set in batch automatically.

User Friendly Control System

Page 34: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

34

Auto clock setting function

Improved Comfort & Convenience

10:00 18:00 9:00 17:00

Summer time Winter time

Touch panel controller Wired remote controller Group remote controller

Auto clock setting function can be used to adjust the clock of all connected remote controllers at once by central

controller.

User Friendly Control System

Page 35: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

35

Auto changeover function

Auto changeover setting allows for the product to easily switch between Cooling and heating modes regardless of

the operation mode of other indoor units.

This can be done via specific indoor unit remote controller and/or by an external input control. This ensures

comfortable operation all year round.

Improved Comfort & Convenience User Friendly Control System

Page 36: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

36

7.5-inch touch screen

Large-sized 7.5-inch TFT color LCD

Easy finger touch operation

Stylish design

Stylish shape and design to suit all application

No additional component is required for installation

Max. 400 controllable indoor units

Up to 400 indoor units can be controlled

Selectable 2 display types (Icon / List) in monitoring mode

Touch Panel Controller

User Friendly Control System

Page 37: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

37

Touch Panel Controller

User Friendly Control System

Installer setting Flexible grouping

Schedule control Password setting

Page 38: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

38

System Controller

Remote centralized control

Max. controllable

4 VRF system

Max. controllable

400 outdoor units

Max. controllable

1,600 indoor units

User Friendly Control System

By using client software, one PC can perform central control and web

control of 10 VRF system sites with max. 20 buildings per site.

On site control Remote central control

Server Server

Server

Server

Max. 4 network system per site Controlled sites of up to 10

Page 39: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

39

User Friendly Control System

Monitor mode (Building)

System Controller

Monitor mode (Site)

Electricity charge calculation

Schedule setting Monitor mode (List)

Page 40: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE 41

Outdoor Unit design

&

Functions

41

Page 41: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE 42

■Low noise design

Significantly reduced noise by optimized airflow structure design

of outdoor unit.

J series J-II series

▲3dB!

at cooling

56 dB

53 dB

6HP class

More Comfort & Convenience

J series J-II series

▲5dB!

at cooling

56 dB

51 dB

5HP Class

Low noise design of outdoor unit

Page 42: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE 43

Large outlet airflow

by steel fan guard

and optimized

bellmouse design

Large intake airflow

by wide space design

Reduced noise of

high rotation range

by optimized fan

blade design

Advanced airflow structure design

Reduce the airflow loss by optimized layout design

φ515

Small angle

Copyright 2011 FUJITSU GENERAL LIMITE, Engineering Support. All rights reserved.

More Comfort & Convenience

Page 43: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Z

Z

Low noise mode

44

Users can choose a low noise level, depending on the

installation environment.

Rated noise value

Low

noise

mode

-5~-6dB

Copyright 2011 FUJITSU GENERAL LIMITE, Engineering Support. All rights reserved.

More Comfort & Convenience

(4~6HP)

Page 44: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Low noise

Low noise design

45

8HP 10HP 12HP 14HP 16HP

VR-II 56 58 58 60 61

[dB] at cooling

Reduced motor vibration

Optimized piping shape

Revised compressor box structure

(Supports new compressor)

(Reduced vibration and resonance)

Page 45: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Low noise

F D M H T

Sound pressure level

(dB)

8HP 56 58 56 58 57

10HP 58 58 57 58 58

12HP 58 60 59 60 59

14HP 60 62 60 62 -

16HP 61 63 61 62 -

46

Comparison

Page 46: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Low noise

Equipped with a low noise mode

Capacity decreasing rate at low noise mode

47

Can be set using - outdoor unit external input & - by the System Controller.

Quiet priority setting Capacity priority setting

Page 47: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

48 AIR INTAKE

High Efficiency Operating System

Smart and cutting edge design

Front intake port

Page 48: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

49

Front Intake

Intake airflow loss

6.7%

FGL

13.4%

D

High Efficiency Operating System

COMPARISON

Intake airflow loss of multiple outdoor units installation

Intake airflow loss

Page 49: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE 50

Easy System Design

50

Page 50: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE 51

■Long piping length

J-II - Design Flexibility

Expansion of total pipe length by adopting advanced refrigerant

flow technology.

Copyright 2011 FUJITSU GENERAL LIMITE, Engineering Support. All rights reserved.

Total pipe

length 180m

max.

40m max.

Pipe length from first separation tube to the farthest indoor unit

120m max.

Actual pipe length

51

30m max.

Height difference between outdoor and indoor units

15m max.

Height difference between indoor and indoor units

Page 51: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE 52

J-II - Design Flexibility

■High capacity connection

2to6units

2to8units

4HP

5HP

6HP

50 to130%

Number of connectable indoor unit range Connectable indoor

unit capacity range Class

2to9units

Copyright 2011 FUJITSU GENERAL LIMITE, Engineering Support. All rights reserved.

Page 52: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Height difference between

outdoor and indoor units

50 m* max.

Height difference between

indoor and indoor units

15 m max.

.

Actual pipe length

165 m max.

Total pipe length

1,000 m max

*For the outdoor unit

stated below. 40 max

53

Pipe length from first separation

tube to the farthest indoor unit

60 m max

V-II & VR-II - Design Flexibility

Page 53: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

High Capacity Connection

Connectable

Indoor unit Capacity range

50 ~ 150%

HP 8 10 12 14 16 18 20 22 24 26 28

Maximum connectable

indoor unit 15 16 17 21 24 27 30 32 35 39 42

HP 30 32 34 36 38 40 42 44 46 48

Maximum connectable

indoor unit 45 48 50 53 57 60 63 64 64 64

Connectable

Indoor unit Capacity range

MAX. 64 unit

54

Page 54: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

55

PIPING SYSTEM

RB unit

- - 3 Pipe system with RB unit

- Selectable 4 method for RB unit connection

Single use 1

Simultaneous use 2

Multi use 3

Cooling only use 4

NEW NEW

Without RB unit

Individual operation,

Reduced connection

Individual operation possible,

Reduced connection

VRF

HEAT RECOVERY

PIPING

SYSTEM

Page 55: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE 56

Design Software

56

Page 56: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

57

Design Software

Model selection & Capacity calculation

Piping design &

Additional charge calculation

Wiring design

Model selection software Design Simulator

Final report

Page 57: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE 58

Easy Installation

58

Page 58: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Easy Connection of Transmission Cable

59

J-II system

V-II system

VR-II system

OK

Uses same communication system for all VRF-II Systems

OK

OK

Page 59: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Flexible Transmission Line Design

60

• Outdoor units and indoor units cannot be directly connected (except some Cooling only units).

• Serial Connection can't be used when there are more than 320 indoor units in the same

VRF network.

Cooling only

or

Parallel connection Serial connection

Total transmission length

3,600m max.

Page 60: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE 61

Easy Installation

■Convenient commissioning support

The address of each indoor unit can be automatically set

by button switch of outdoor unit.

Automatic address setting function

Press the push button

switch of outdoor unit.

Copyright 2011 FUJITSU GENERAL LIMITE, Engineering Support. All rights reserved.

Page 61: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE 62

Connection check function

・Display connected indoor unit numbers

・Display address number of each indoor unit

Easy Installation

Possible to confirm whether wiring connection and address

setting are correct by connection check function for a short

time .

Copyright 2011 FUJITSU GENERAL LIMITE, Engineering Support. All rights reserved.

Page 62: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Not allotted to

unconnected

indoor units

Convenient Commissioning Support

Automatic address setting

63

Automatically sets the Indoor unit, Signal amplifier, and RB unit addresses.

5 6 1 7

Signal amplifier

address

4 3

5

1

6 1 7 4 3 2

Indoor unit

address

RB unit address

1

2

3

8

Page 63: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Address Setting from Remote Controller

Manual address setting The indoor unit address can be manually set using the remote controller.

64

01-01 01-02 01-03

or

02-01

Caution

The RB unit and signal amplifier address cannot be set using the remote controller.

Page 64: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Address Setting by Manual

Manual address setting The address can be set in the main unit as previously.

65

01-04 01-04

01-01

@Multi type RB-units one address is required for

each branch.

Indoor Unit

RB-unit

Signal

Amplifier

Page 65: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

66

For Simplified Installation

Installer Setting from RC

UnErroness wiring

7 Seg display

Commissioning Wizard

Page 66: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

67

High Static Pressure 80Pa

Powerful air discharge providing an external static pressure of 80Pa.

F D M H T

Static Pressure(Pa) Max.80 Max. 78.4 Max. 60 Max. 60 Max. 50.

Page 67: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

68

Easy Installation

Easily transported and connection

Transporting by

forklift

Transport with forklift is

possible

Easily craned

using lifting belt hooks

Design of outdoor unit allows

for

lifting straps to be used.

Can be transported in

a small elevator

Flexible piping connection

Page 68: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE 69

Easy Installation

VR-II RB-Units

69

Page 69: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Flexible Installation of RB Unit

70

UTP-RX04AH

F D M

Height 198 207

width 298 388

depth 268 326

Required

Space 240 317

F D M

Height 260 209 284

width 658 1053 648

depth 428 326 432

Required

Space 300 509 384

UTP-RX01AH

UTP-RX01BH

UTP-RX01CH

198

268

298

240

Small, slim design ・Single type

・Multi type

654 428

260 300

4 outlet type comparison

240

300

[unit : mm]

[unit : mm]

Page 70: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

71

PIPING SYSTEM

RB unit VRF

HEAT RECOVERY

Multi RB unit 2

1. Thin design

Single RB unit 1

FGL D M

Height 198 207 NA

Width 298 388

Depth 236 326

Required

Space 240 317

198mm

Height

2. Flexible Design

Page 71: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Control box position can be changed

72

Control box (standard position)

Control box Ceiling

Obstacle

Flexible Installation of RB Unit

Page 72: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

73

Control box can be moved to the top

Electrical component box

FGL only

198

268

Flexible Installation of RB Unit

Page 73: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Flexible Design by RB Unit

74

UTP-RX01AH:2.2 - 8.0kW UTP-RX04BH:2.2-18.0kW x 4-branch

UTP-RX01BH:2.2 - 18.0kW

Single type Multi type

Total 4 type of RB units are provided to match various installation location restrictions

RB unit Fujitsu Daikin Mitsubishi

Single type

2.2 - 8.0 2.2-11.2

None 2.2 - 18.0 11.3-18.0

2.2 - 28.0 18.1-28.0

Multi type 2.2-18.0 x 4-branch 2.2-11.2 x 4-branch

15 types 2.2-11.2 x 6-branch

[kW]

RB unit Line-up

UTP-RX01CH:2.2 - 28.0kW

Page 74: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

75

UTP-RX01AH: Max 3 units, total capacity up to 8.0kW

UTP-RX01CH: Max 8 units, total capacity up to 28.0kW

Group connection* for each RB unit is possible

UTP-RX04AH:4-branches, total capacity is up to

56kW Multi type

Single type

For each branch: Max 8 units, total capacity is up to 18.0kW

1-branch

*Cooling/Heating changeover for each RB unit

Flexible Design by RB Unit

UTP-RX01BH: Max 8 units, total capacity up to 18.0kW

Page 75: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

76

Flexible Design by RB Unit

Cooling/Heating priority order can be changed for each RB unit.

RB unit

③ External Input

(Dry Contact & Apply Voltage)

② Administrative Indoor Unit ① First Command

(Factory Setting)

Case of Multi type RB unit, it can be set for each Branch individually.

Group connection for each RB unit is possible

or

Page 76: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

77

→Possible to operate annual cooling for some rooms inside the

building.

RB unit is not required

Flexible Design by RB Unit

RB unit

On Off

Possible to operate on/off with each Indoor unit.

Remote Controller can't select Heating operation.

Cooling only operation is possible without RB unit

Page 77: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Improved single type installability

79

The RB unit can be freely positioned to match the floor layout.

Flexible Design by RB Unit

max. 60m

No limitations on RB unit location

1st branch RB unit RB unit

Page 78: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Improved Multi type installability

80

・Can be connected from both sides depending on the installation location restrictions.

Competitors

Example installation

FGL

FGL Competitors

Flexible Design by RB Unit

Page 79: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

81

Improved Multi type installability ・UP to 2 Multi type RB units can be directly connected.

Competitors

Example installation Up to 56kW

FGL

Flexible Design by RB Unit

1m or less

Page 80: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE 82

Easy Service

&

Maintenance

82

Page 81: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

室外機からの修理性向上

In the case of multi unit installation,

workability is substantially improved

by using a removable L-Shape front

panel and corner cut design

Expansion of work space

83

Design for Easy Service and Maintenance

Inspection and replacement of main parts are easier

due to innovative construction and an LED operational display.

Page 82: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

EEV Connection Error of VRF-II Outdoor unit is newly added

EEV Connection Error

84

Detect connection error

Electric Expansion Valve(EEV)

(Used in 3 locations)

Control box inside outdoor unit (14/16HP)

Page 83: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Backup Operation (only connected units)

Complete stoppage of the air conditioner during a malfunction is

prevented.

85

Backup operation might not be conducted depending on the type of

problem.

Operation can be continued using the backup operation function.

Page 84: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

86

Diagnosis by Service Tool

Easy system status check

Page 85: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Update version for UTY-AMGX

Network Topology Analysis

Make a topological display of units connected to VRF network system by

segments.

(Objects for display : indoor units, outdoor units, signal amplifier, controller)

87

Error

Functions of Service Tool

Page 86: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Update version for UTY-AMGX

Remote setting

Function setting of indoor units, which is configured by remote controller,

can be set up remotely.

88

Function No.11

0 ⇒ 1

Functions of Service Tool

Page 87: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Update version for UTY-AMGX

Clock setting

The clock of each VRF system device (remote controller, etc) can be set

remotely with setting of time and date.

89

Functions of Service Tool

Page 88: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Maintenance using New wired R.C.

90

Maintenance and inspection support without special

tools

60℃

250pls

ARXD12

GALH Temp error!!

You can see various information* from New Wired R.C.

Error History Sensor Value

Setting Status Indoor Unit Address

*Various Information can be detected

only Indoor unit connected by New wired R.C.

Page 89: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE 91

Easy Service

&

Maintenance

VR-II BR-Box

91

Page 90: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

RB unit failure repair

Easy maintenance construction • Single RB unit • Multi RB unit

The coil of solenoid valve can be

removed from the side The control box can be temporarily

positioned out of the way by sliding it down.

92 Top view

Maintenance

hole

Page 91: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

93

RB unit failure repair

Competitor’s product construction

The coil of expansion valve can only be replaced from the top

Space

Cover

Hard to

reach…

Page 92: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE 94

Promotion Tools

94

Page 93: VRF- II - columbus-klima.hu Series... · option line up . new. new. utp-rx01bh . utp-rx04bh . utp-dx567a . utr-h0906l . utr-h1806l . utr-h0908l . utr-h1808l . utp-j0908a . utp-j1808a

© 2011 Fujitsu General Limited TENTATIVE

Promotion tools & material Catalog

Design & Technical Manual

Service Manual

Promotion Movie

Design Simulator

Product CAD data

95 Revit 3D RFA data AutoCAD 2D DXF data