water and sediment determination by automatic...

2
www.koehlerinstrument.com BOHEMIA, NEW YORK HOUSTON, TEXAS Water and Sediment Determination by Automatic Centrifuge

Upload: ngoliem

Post on 17-May-2018

236 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: Water and Sediment Determination by Automatic …store.clarksonlab.com/Vendors/Koehler_K60002_Centrifuge.pdfWater and Sediment Determination by Automatic Centrifuge. ... (ASTM D91,

www.koehlerinstrument.comBOHEMIA, NEW YORK • HOUSTON, TEXAS

Water and Sediment Determination by Automatic Centrifuge

Page 2: Water and Sediment Determination by Automatic …store.clarksonlab.com/Vendors/Koehler_K60002_Centrifuge.pdfWater and Sediment Determination by Automatic Centrifuge. ... (ASTM D91,

1595 SYCAMORE AVENUE • BOHEMIA, NEW YORK 11716-1796 1-800-878-9070 (in u.s. only) • TEL: +1 631 589 3800 • FAX: +1 631 589 3815www.koehlerinstrument.com • Email: [email protected]

© 2011 Koehler Instrument Company, Inc.

Test MethodCentrifugation provides a convenient means of determining sediment and water content in crude oil, fuel oils, middle distillate fuels, and biodiesel. Also used in determining the precipitation number, demulsibility characteristics, trace sedi-ments, and insolubles in used lubricating oils.

Automatic Heated Oil Test Centrifuge • Choiceoflong,short,pear,orfingerrotorassemblytoaccommodate correspondingcentrifugetubes• Accommodatesfour(4)centrifugetubesof6or8”conicalASTMtypes,long, short,pearorfingertubes• Automaticcontrolofaccelerationramp,centrifugationspeed,andtimingfunctions.• 4-1/2”LCDTouchScreenControlPanel• SubstantialInsulationforReducedHeatLoss• Precisebalancing,QuietOperation• Large,clear,topopeninglid• Class1,Division2explosionresistantrating

Fully automatic bench top centrifuge designed expressly for petroleum testingapplications. Features a 4-1/2” LCD touch screen control panel. This integrated touchscreen can be used to turn the heat on and off, set the duration of the test, set theRCF/RPM values and choose the type of rotor assembly and corresponding glasswareto be used during the test. The Servoed motor speed mechanism allows the userto simply set the desired speed and the instrument will attain that speed. Thismechanism calculates RPM based on the given RCF and type of Rotor selected. Thelarge, clear, topopening lidprovides for easyaccess to the rotor and tubeholdersandfor cleaning of the unit. The lid has a 18-1/2” diameter viewing window allowing theoperator to view inside the chamber for checking the status of the rotor and check-ing for possible spillage of the centrifuge tubes. Molded PTFE cushions provide formaximumprotectionandeasypositioningofthetubes.

Safety FeaturesTheCentrifugecomesequippedwithaSafetyLockoutMechanism.Uponemergencyshut-downthedoor is lockedandcannotbeunlockeduntil theunitcomestoacompletestop,theunitisturnedbackon,andthestop/unlockkeyispressedonthetouchscreendisplay.Furthermore,thecentrifugecannotstartwhilethedoorofthechamberisopenandthelatchisnotengaged.The“NitrogenPurge”featureallowsforaslowreleaseofNitrogenintothebowlofthecentrifuge.ThisfeaturerequiresanexternalNitrogenGassourceandcaneasilyconnecttoanInletportlocatedatthebackoftheunit

Specifications Conformstothespecificationsof: ASTMD91,D96,D893,D1796,D1966,D2273,D2709,D2711,D4007,D5546; IP75,145,359;API2542,2548;ISO3734;DIN51793;NFM07-020Capacity:Four(4)oiltestcentrifugetubes:long(100mL),short(100mL),pear(100mL),orfingertubes(12.5mL)MaximumSpeed:2200RPMMaximumRCF:1327(long);1170(short);865(pear-shaped)Timer:0to999minSetSpeed:200-2200RPMSpeedReadout:0-2200RPMTemperatureControl:ambientto93°C(200°F)TemperatureReadout:DigitalBrake:AutomaticDynamic

Electrical Requirements115V60Hz,7A 230V50/60Hz,3.5A

Dimensions lxwxh,in.(cm)31x25.8x14.3(78.74x65.53x36.32) NetWeight:98lbs(44.5kg)

Shipping InformationShippingWeight:122lbs(55.4kg) Dimensions:36x30x19in.

Catalog No. K60002 AutomaticHeatedOilTestCentrifuge,115V60HzwithLongTube RotorAssemblyK60092 AutomaticHeatedOilTestCentrifuge,230V50/60HzwithLongTube(RA*)K60002-ST AutomaticHeatedOilTestCentrifuge,115V60HzwithShortTube(RA*)K60092-ST AutomaticHeatedOilTestCentrifuge,230V50/60HzwithShortTube(RA*)K60002-PT AutomaticHeatedOilTestCentrifuge,115V60HzwithPearTube(RA*)K60092-PT AutomaticHeatedOilTestCentrifuge,230V50/60HzwithPearTube(RA*)K60002-FT AutomaticHeatedOilTestCentrifuge,115V60HzwithFingerTube(RA*)K60092-FT AutomaticHeatedOilTestCentrifuge,230V50/60HzwithFingerTube(RA*)*RotorAssembly

Accessories K60002-LT-1 RotorAssemblyforLongTubesK61101 CentrifugeTube,Long,100mL,8”,markedinmL (ASTMD91,D96,D893,D1796,D4007)K61106 CentrifugeTube,Long,100mL,8”,markedin200parts(ASTMD96)K61110 CentrifugeTube,Long,100mL,8”,markedinmLevery1mL above10ml(ASTMD96,D4007)K61112 CentrifugeTube,Long,100mL,8”,markedin200partsevery 2partsabove20parts(ASTMD96)K61109 CentrifugeTube,Cone-Shaped,100mLwithcapillarytipcapable ofmeasuring0.01mLandreadablebyestimationto0.005% (ASTMD2273,D2709)(K61153cushionrequiredforeachtube)K61135 PTFEcushionforLongTubesK61153 PTFEcushionforLongTubeswithcapillarytip (RequiredforK61109tubes)K60002-ST-1 RotorAssemblyforShortTubesK61102 CentrifugeTube,Short,100mL,6”,markedin200parts every4partsabove20mL(ASTMD96)K61105 CentrifugeTube,Short,100mL,6”,markedinmL(ASTMD96)K61107 CentrifugeTube,Short,100mL,6”,markedinmLevery 2mLabove10mL(ASTMD96)K61108 CentrifugeTube,Short,100mL,6”,markedin200parts(ASTMD96)K61146 PTFEcushionforShortTubesK60002-PT-1 RotorAssemblyforPearTubesK61104 CentrifugeTube,Pear,100mL,markedinmL(ASTMD1966)K61152 CentrifugeTube,Pear,100mL,withtubetiphavinggraduations of0.01mLovertherange0to0.2mL(ASTMD2709)K61111 CorkStopperforLong,ShortandPearTubesK60002-FT-1 RotorAssemblyforFingerTubesK61141 CentrifugeTube,FingerTube(API2542)K61136 FeltsupportforFingerTubeK61132 CorkStopperforFingerTube

Ordering Information

K60002 Automatic Heated Oil Test Centrifuge

Water and Sediment Determination by Automatic Centrifuge