weekly centralized controller for indoor units …hokkaido.by/images/doc/37.pdf · weekly...
TRANSCRIPT
- 1 -
WEEKLY CENTRALIZED CONTROLLERFOR INDOOR UNITS
USER'S MANUAL
WARNING!PLEASE READ THIS MANUAL BEFORE USING YOUR NEW WEEKLY CENTRALIZED CONTROLLER.
DTCWT IHXR Model
- 2 -
Table of Contents
SAFETY PRECAUTIONS ......................................................................................................... 3
INSTALLATION ........................................................................................................................ 4
INDICATORS ON WEEKLY CENTRALIZED CONTROLLER .................................................. 8
BUTTONS ON WEEKLY CENTRALIZED CONTROLLER ..................................................... 10
HOW TO USE THE WEEKLY CENTRALIZED CONTROLLER ............................................. 12
ERROR CODES ..................................................................................................................... 21
- 3 -
SAFETY PRECAUTIONSIN
STAL
LATI
ON
WAR
NING
OPE
RATI
ON
CAUT
ON
Installationcommitment
WARNING
• Please always contact the Retailer or the AuthorizedTechnical Service for installation of the Weekly CentralizedController.Users must not install the Weekly Centralized Controller bythemselves.A wrong installation may cause electric shocks, injuriesor fire.
Do not spray inflammable liquid on the Weekly CentralizedController, or fire may be caused.
Do not operate with wet hands.Do not let water go into the Weekly Centralized Controller, toavoid the danger of electric shocks.
!
Markers Icons
Icons
Please read the Safety Precautions carefully before using DTCWT - IHXR Weekly CentralizedController. Do observe the following Safety Precautions, for they are very important.Before reading the text, please be familiar with the following markers and icons, and complywith the Precautions.
• The User must never attempt to install or repair the Weekly Centralized Controller byhimself.
• A strict observance of the following instructions will prevent personal hurt and incidents to theUser. Moreover, correct operation and long life of the appliance will be ensured.
WARNING
CAUTION
Indication Indication
The sign shows the risk ofdeath or serious injury willbe caused due to the wrongoperation.
FORBID. Action or procedure not allowed,with serious effects on objects and people.
ENFORCE. Compulsory acton or procedure.The missed observance could bring seriouseffects on objects and people.
The sign shows the risk ofinjury or the damage to theproperty will ba caused dueto the wrong operation.
Markers
FORBID
FORBID
If you want to move or re-install your Weekly CentralizedController, please always contact the Authorized TechnicalService.
Do not disassemble your Weekly Centralized Controller.If you need to disassemble the Weekly Centralized Controller,please contact the Authorized Technical Service.A wrong disassembly may cause abnormal operation oroverheating, which may result in fire.
MO
VE
AN
D R
EP
AIR
CA
UT
ION
!
!
!
- 4 -
INSTALLATION
System Wiring Instructions
1. Connecting diagram for air-conditioning system with central network
2. Other relevant explanationThere are two kinds of Indoor Unit:- Indoor Unit with built-in network module- Indoor Unit with external network module.
a) Connecting diagram 1
IndoorUnit
IndoorUnit
Indoor Unit
MD-NIM01
X Y E
MAX=64
IndoorUnit
IndoorUnit
IndoorUnit
IndoorUnit
IndoorUnit
Weekly-Timer Central Controller
Weekly-Timer Central Controller
Weekly-Timer Central Controller
IndoorUnit
IndoorUnit
IndoorUnit
IndoorUnit
IndoorUnit
b) Connecting diagram 2
- 5 -
INSTALLATION
Accessory List
Installation Instructions
The following is the packing list of DTCWT - IHXR Weekly-Timer Central Controller.Confirm whether it contains all accessories.
Field installation accessories prepared
Installation Instructions to the Central Controller:Directly connect 20V~50/60Hz to ends L and N of the socket on the back of the CentralController.
1.
2.
3.4.
5.
6.
Correct connection Wrong connection Wrong connection Wrong connection
The signal cable and power cable of the Central Controller cannot be contained in the samecable tube. The distance between the signal cable tube and power cable shall be between300 mm ~ 500 mm at least.The total signal cable length of the Central Controller shall not exceed 1,200 m.Make sure there is no joint in the middle of the shielded cable. If such a joint exists, use asocket to connect it.After finishing the connection of the Central Controller, do not use megger to check theinsulation of the signal cable. Connecting mode between the Central Controller and network interface:The communication port between the Central Controller and the network interface of theair conditioning system is polar. The X, Y, E pins on both sides shall be corresponding andcannot be cross-connected.
Nb. Name Quantity
Nb. Name Quantity Remarks
Used for communicating with the IndoorUnit of the air conditioning system
Used for the supplying power to the Weekly-Timer Central Controller
Used for binding cable(according to the specific situation)
1 piece
1 piece
4 piece
1 piece
1 piece
1 piece
3 pieces
several
6 pieces
6 pieces
Weekly-Timer Central Controller
Cross-head screw
Screw anchor
User’s Manual (Installation & Operating Instructions)
120 Ohm resistor for XY line
Three-core shielded cable
Three-core cable
Switch case
Cable tubes
Cable tie
1
2
3
4
5
1
2
3
4
5
- 6 -
INSTALLATION
Y E L N
Installation Method
The installation method of the Central Controller using electrician switch case.
The thickness of the Central Controller cable shall be adjusted according to thelength of the cable. A proper cable tube shall be used to install the cable of the CentralController.Insert the flap tip screwdriver into the 2 recesses on the top panel of the case andslightly turn to open the top cover of the Central Controller.
Dimensions: as shown in the rightdiagram.
Installation screw hole (4)
Slightly turn flat tip screwdriver to openthe top cover (2 recesses)
Screws used for fixing the CentralController
Base
Top cover
Power connector of the Central Controller 220V/ACON OFF
COM OFF---COM: Emergency Stop Switch, used to shut down all air conditioners.OFF---COM: Emergency Open Swith, used to start up all air conditioners.
Communication interface to the Indoor Unit.
70.5
83.5
48.5
136
92
- 7 -
INSTALLATION
Installation Method
Connecting diagram of network-based air conditioning system
IND
OO
RUNIT
(M
AX)
POW
ER S
UPP
LY=
220V/A
C
IND
OO
RU
NIT
(32)
IND
OO
RU
NIT
(10)
IND
OO
RU
NIT
(1)
IND
OO
RU
NIT
(0)
(There are 2 types of Indoor Units: a) with external network interface module in themain control board; b) with built-in network interface module in the main controlboard)
- 8 -
INDICATORS ON WEEKLY CENTRALIZED CONTROLLER
Tim
e
On-l
ine
conditio
nm
atrix
table
of ai
rco
nditio
ner
s 0-6
3Q
uer
ySet
Ope
rate
resu
lt
Ru
n M
od
e:
Aut
o, C
ool, H
eat,
Fan,
Dry
Wee
kly
Tim
erO
ffLo
ckRem
oter
Lo
ckH
eat
Lock
Coo
l
Lock
Keyb
oard
Ele
ctric
Auxi
liary
Hea
ter
Sw
ing
Econ
omy
Run
Fan
Sp
eed
:H
igh,
Mid
dle
, Lo
w
Indicators’ description of the Weekly-Timer Central Controller
1) General drawing of the liquid crystal display of the Weekly-Timer Central Controller
- 9 -
INDICATORS ON WEEKLY CENTRALIZED CONTROLLER
2) LCD icon description of the Weekly-Timer Central Controller
Icon Meaning
Automatic Mode
Cool Mode
Heat Mode
ElectricAuxiliaryHeater
Lock Cool
Lock Keyboard
Querying
Weekly Timer Off
Online
Error
Tuesday
Thursday
Saturday
Period 1, 2, 3, 4
T2A Liquid Side Temp. (I.U.)T2B Gas Side Temp.(I.U.)T3 Outdoor Pipe Temp.
Room Temperature
Monday
Wednesday
Friday
Sunday
Set Temperature
Protecting
Lock Remoter
Setting
Operate Result
All
Lock Heat
Fan Speed:High/Medium/Low
Dry Mode
Fan Only Mode
Icon Meaning
- 10 -
BUTTONS ON WEEKLY CENTRALIZED CONTROLLER
Buttons’ description of the Weekly-Timer Central Controller
1) General key layout of the Weekly-Timer Central Controller
2) Key instructions of the Weekly-Timer Central Controller
Confirm tosave
On/OffWeekly-Timer
Enter thesetting page of
theWeekly Timer
Set Time
Confirm
Cancel
Time Weekly Query Set Add Mode Fan Swing
LockResetReduce
Program
QueryAir Conditioner
SetAir Conditioner
Used to select theair conditioner tobe set or queried
SetRun Mode
ResetDefaultSettings
Per annullarel’operazione
corrente
Set Lock
SetSwing
SetFan Speed
Key Name Usage
Press “ON/OFF” button. All air conditioners will be shut down if they are running. On thecontrary, they will be started up. If you press the button for less than 5 seconds, the startupmode is the last running mode of the air conditioner. If you press the button for more than 5seconds, the startup mode is Cooling, High Speed, 24°C.
Press “SET” button and select “set single” or “set all”. “Set single” indicates to set the parameter(such as Mode/Temperature/Fan Speed/Weekly Timer) of a selected air conditioner.“Set all” indicates to set the parameter of all air conditioners controlled by the Central Controller.
Press “QUERY” button to query the running condition of the air conditioner, such as On/Off,Temperature Setting, Indoor Temperature, Running Mode and Fan Speed. Press “Up”,“Down”, “Left” and “Right” buttons to select the air conditioner that you would like to query.
“Up” button. When querying or setting the Indoor Unit, press this button to select the IndoorUnit to be set or queried.
“Down” button. When querying or setting the Indoor Unit, press this button to select the IndoorUnit to be set or queried.
- 11 -
BUTTONS ON WEEKLY CENTRALIZED CONTROLLER
When querying the Indoor Unit, press “ADD” button to query more parameter of the Indoor Unit.In setting the Indoor Unit, it is for modifying the setting temperature. In setting the WeeklyTimer, it is for modifying the time of startup and shutdown.
When querying the Indoor Unit, press “REDUCE” button to query more parameter of the IndoorUnit. In setting the Indoor Unit, it is for modifying the setting temperature. In setting the WeeklyTimer, it is for modifying the time of startup and shutdown.
When setting the Indoor Unit, it is used for setting the running mode, which includes Automatic,Cool, Heat, Fan, Dry modes and Off (shutdown of the air conditioner). You can select amongthem.
When setting the Indoor Unit, it is for setting the fan speed, which includes High speed, Middlespeed, Low speed and Automatic speed. You can select among them.
When setting the Indoor Unit, it is for setting the swing function. The running mode is selectedbetween “Swing-on” and “Swing-off”.
When setting, press “LOCK” button to lock the remote controller of all or single Indoor Unit.Press the “QUERY” button and hold under the main page, then repress the “LOCK” buttonagain to lock the keyboard of the Central Controller; press the “MODE” button and thenrepress the “LOCK” button to lock the running mode.
If you press this button, default settings are restored, as when power is restored after apower failure.
Under the main page, press “PROGRAM” button to set the Weekly Timer of “single indoor unit”or “all indoor units”. Press the “QUERY” button and hold, and press the “PROGRAM” buttonto query the Weekly Timer parameters of the Indoor Unit.
Under the main page, press the “WEEKLY” button to start up or shut down the Weekly Timerfunction.
Under the main page, press the “TIME” button for 5 seconds to enter the time-modifyingstatus, and then press “ADD” or “REDUCE” button to modify the time. Press “Left” or“Right” button to select Minute / Hour / Day / Month / Year. Finally, press the “CONFIRM”button to save the modification.
Save data and send the command required to the Indoor Unit, such as setting the modeof the air conditioner.
Cancel the last operation and return to the last interface.
“Left” button. When querying or setting the Indoor Unit, press this button to select the IndoorUnit to be set or queried. In setting the Weekly Timer, it is used for selecting the day of theweek and the time of startup and shutdown.
“Right” button. When querying or setting the Indoor Unit, press this button to select the IndoorUnit to be set or queried. In setting the Weekly Timer, it is used for selecting the day of theweek and the time of startup and shutdown.
Cancel
- 12 -
HOW TO USE THE WEEKLY CENTRALIZED CONTROLLER
a) The main interface of the Weekly-Timer Central Controller (User Interface)
b) Setting interface of single Weekly-Timer Central Controller
Under the other pages, press button to return to the main interface.1)
Under the other pages, automatically return to the main interface when no operationis perfomed for a period of time.
2)
The main interface displays the on-line condition of the Indoor Unit.3)
Under the main interface, press button to select the interface for the settingof a single air conditioner.
1)
Automatically return to the main interface when no operation is performed for a periodof time.
2)
Set the running status of a single air conditioner under this page.3)
Sixty-one Indoor Unitsare on-line.
Date The on-line condition of the Indoor Unit
Cancel
Set
Indoor Net-addressSet Temperature
20°C CoolSetting Set
Successfully
High SpeedRoom Temperature
28°C
- 13 -
HOW TO USE THE WEEKLY CENTRALIZED CONTROLLER
d) Unified setting interface of the Weekly-Timer Central Controller (all air conditioners)
c) Setting interface of Weekly Timer parameters of a single air conditioner
Under the main interface, press to display the parameter setting interface of asingle Weekly Timer.
1)
Automatically return to the main interface if no operation is performed for a period oftime.
2)
Under this page, set the Weekly Timer parameters of a single air conditioner, includingStartup Time, Shutdown Time, the Running Mode of this period, Temperature and Fan Speed.
3)
One air conditioner can be at most st with four periods in one day from Monday to Sunday,seven days in total.
4)
Under the main interface, press button to display the unified setting interface.1)
Automatically return to the main interface if no operation is performed for a period of time.2)
Set the running mode of all air conditioners under this page, including Mode, Temperatureand Fan Speed.
3)
Program
Set
Time on Time off
Period 1
Monday
AllIndoor Units
Weekly-Timer offLockRemoter
LockCool
Setunsuccessfully
- 14 -
HOW TO USE THE WEEKLY CENTRALIZED CONTROLLER
e) The operating flow description of the Weekly-Timer Central Controller
1) How to set the running status of the air conditioner?
1. Press button to enter the setting status interface of single air conditioner. Press the button repeatedly
to select “Single” and “All” alternately; the display shows “Set”.
If you select “Single”, press buttons to select one.
2. Selecting “All”, indicates to set the running status of all air conditioners, and “All” is displayed. Selecting “Single”
displays the address of a single air conditioner: for example, if the air conditioner whose address is 12 is selected,
“12#” is displayed.
3. Press button to select running mode: Automatic, Cooling, Heating, Fan Dry, or Off (shutdown of the air
conditioner). If you select “Off”, press button to send shutdown command, finishing shutdown setting.
4. If you select Cooling Mode or Heating Mode, press buttons to adjust the Temperature (the scopeis within 17°C~30°C).There is no temperature adjustment for other modes.
5. Press button to regulate Fan Speed, which can be selected among Automatic, Low, Middle and HighSpeed.
7. Press button to save the above setting and send input to thecorresponding air conditioner. The setting is finished.
1. Press button to enter the query status of a single air conditioner; the display shows “Query”.Press buttons to select one air conditioner.
2. Press buttons to view more parameters of the air conditioner.
6. Press button to activate automatic swinging of louver.
2) How to query the running status of the air conditioner?
Query
ADD REDUCE
Set
Add Reduce
Fan
Mode
Confirm
Confirm
Swing
Under the maininterface
Under themain interface
- 15 -
HOW TO USE THE WEEKLY CENTRALIZED CONTROLLER
3) How to lock and unlock the Remote Controller of the air conditioner?
4) How to lock and unlock the mode of the air conditioner?
1. Press button to enter the setting status interface of a single air conditioner. Press the button
repeatedly to select “Single” and “All” alternately. The display shows “Set”.
If you select “Single”, press buttons to select one air conditioner.
2. Selecting “All”, indicates to set the running status of all air conditioners, and “All” is displayed. Selecting
“Single”, displays the address of a single air conditioner: for example, if the air conditioner whose address
is 12, “12#” is displayed.
3. Press button to send the lock or unlock command of the remote controller to the correspondingair conditioner and finish setting.
1. Press and hold button, and then press button.
2. The keyboard will be locked if it is unlocked.If it is locked, it will be unlocked.
5) How to lock and unlock the keyboard of the Weekly-Timer Central Controller?
Query Lock
Set
Lock
Mode Lock1. Press button and hold, then press button to enter the setting interface of the mode-locking.
2. If the air conditioner is in the mode of unlocking, press buttons to select cooling-locking orheating-locking. Press button to send mode-locking command.
3. If the air conditioner is in the mode of locking, press button to send the selected unlock commandto all air conditioners.
Confirm
Confirm
Under themain interface
Under themain interface
Under themain interface
- 16 -
HOW TO USE THE WEEKLY CENTRALIZED CONTROLLER
Press button to select the dayof the week to the next step.
6) How to set the function and relevant parameters of the Weekly Timer of the air conditioner?
Program
Mode
Add Reduce
Add Reduce
Fan
1. Press button to enter the setting status interface of a single air conditioner. Press the button repeatedlyto select “Single” and “All” alternately. The display shows “Set”.If you select “Single”, press to select one air conditioner.
2. Selecting “All”, indicates to set the Weekly Timer parameters of all air conditioners, and “All” is displayed. Selecting“Single” displays the address of the air conditioner: for example, if the air conditioner whose address is 12, “12#”is displayed.
4. Set the parameters of Period 1, including Shutdown Time, Startup Time, Running Mode, Fan Speed andTemperature. First of all, set the Startup and Shutdown Time. Press buttons to select the Startup andShutdown Time. Press to modify the Startup and Shutdown Time.
5. Press button to select Running Mode: Automatic, Cool, Heat, Fan, Dry, or Off. If you select the Cool,Automatic or Heat mode, press buttons to adjust the Temperature (the scope is within 17°C~30°C).Press button to regulate Fan Speed, which can be selected among Automatic speed, Low speed, Middle speedand High speed.
6. Finish the Weekly Timer parameter setting of Period 1.
7. Set Periods 2, 3, 4 according to the above operation.
8. After finishing the setting of each Period, select in sequence the Days of the Week to set the parametersof the Weekly Timer from Monday to Sunday, seven days in total.
Finish setting
Confirm
Cancel
Cancel
Confirm
Cancel
Confirm
ConfirmConfirm
CancelConfirmConfirm
Under themain interface
Press button toselect air conditioner to the next step.
Press button to save theparameter of the Period 1 to the next step.
Press button to save theparameter of the Period 1 to the next step.
Press button to cancel theselection and return to the last step.
Press button to cancel theselection and return to the last step.
Press button to cancel theset of Period 1 and return to the last step.
Press button to cancel theset of Period 1 and return to the last step.
3. Press buttons to select the Day of the Week.
- 17 -
HOW TO USE THE WEEKLY CENTRALIZED CONTROLLER
7) How to close the Weekly Timer setting related to a Period?
Program
Mode
Add Reduce
1. Press button to enter the setting status interface of a single air conditioner. Press the button repeatedlyto select “Single” and “All” alternately. The display shows “Set”.If you select “Single”, press buttons to select one air conditioner.
2. Selecting “All”, indicates to set the Weekly Timer parameters of all air conditioners, and “All” is displayed. Selecting“Single” displays the address of a single air conditioner: for example, if the air conditioner whose address is 12,is selected, “12#” is displayed.
4. Set the parameters of Period 1, including Shutdown Time, Startup Time, Running Mode, Fan Speed andTemperature. First of all, set the Startup and Shutdown Time. Press buttons to select the Startup andShutdown Time. Press buttons to modify the Startup and Shutdown Time.
5. Press button to select Running Mode: Automatic, Cool, Heat, Fan, Dry, or Off.Select “Off” mode.
6. Finish shutting down the Weekly Timer function related to Period 1.
7. Shut down the Timer during Periods 2, 3, 4 according to the above operation.
Finish setting.
3. Press buttons to select the Day of the Week.
Confirm
Cancel
Cancel
Confirm
Cancel
Confirm
ConfirmConfirm
Cancel
Under themain interface
Press button to selectair conditioner to the next step.
Press button to save theparameter of the Period 1 to the next step.
Press button to save theparameter of Period 1 to the next step.
Press button to cancelthe selection and return to the last step.
Press button to cancel theset of Period 1 and return to the last step.
Press button to cancel theset of Period 1 and return to the last step.
Press button to cancel theset of period 1 and return to the last step.
ConfirmConfirmPress button to save theparameter of the Period 1 to the next step.
- 18 -
HOW TO USE THE WEEKLY CENTRALIZED CONTROLLER
8) How to query the Weekly Timer setting parameters of the air conditioner?
9) How to start up or shut down the Weekly Timer function of all air conditiioners?
Program
Query
1. Press button to enter the query status of a single air conditioner. The display shows “Query”. Thenpress button to query the Weekly Timer parameters.Press buttons to select the air conditioner that needs to be queried.
2. Selecting “All”, indicates to set the Weekly Timer parameters of all air conditioners, and “All” is displayed. Selecting“Single” displays the address of a single air conditioner: for example, if the air conditioner whose address is 12 isselected, “12#” is displayed.
4. Press buttons to select the Weekly Timer parameters of the queried Periods 1, 2, 3, 4.
5. Query the Weekly Timer parameters of any Indoor Unit within any time according to the above operation.
3. Press buttons to select the Day of the Week.
Cancel
Cancel
ConfirmConfirm
ConfirmConfirm
Under themain interface
Under themain interface
1. Press button.
2. If the Weekly Timer functionis shut down, it will be started up;if the Weekly Timer function is started up, it will be shut down.
3. If the Weekly Timer function is shut down, the display shows “Weekly Timer Off”.
Press button to selectair conditioner to the next step.
Press button to select theDay of the Week to the next step.
Press to cancel theselection and return to the last step.
Press button to cancel theselection and return to the last step.
Weekly
- 19 -
HOW TO USE THE WEEKLY CENTRALIZED CONTROLLER
10) How to modify the system Time?
Under themain interface
1. Press button for 5 seconds to enter the Time-setting interface.
3. First, press buttons to select the Year that needs to be modified.
4. Press buttons to modify the Year.
5. Press buttons to select the Month that needs to be modified.
6. Press buttons to modify the Month.
7. Press buttons to select the Day that needs to be modified.
8. Press buttons to modify the Day.
9. Press buttons to select the Hour that needs to be modified.
10. Press buttons to modify the Hour.
11. Press buttons to select the Minutes that need to be modified.
12. Press buttons to modify the Minutes.
13. Press button to save the modification.
2. Press buttons to select Minute / Hour / Day / Month / Year that need to be modified.
Confirm
Time
Add Reduce
Add Reduce
Add Reduce
Add Reduce
Add Reduce
- 20 -
HOW TO USE THE WEEKLY CENTRALIZED CONTROLLER
An example to show the function of the Weekly Timer
Example: Take the Indoor Unit with “04” address, set the Weekly Timer and start up theWeekly Timer function according to the procedure illustrated on the previous pages.The following Table shows an example of Timer setting.
From the above Table, we can see that Timer has been set for 2 days every week, namelyMonday and Tuesday.In particular:• Monday foresees 3 Periods of setting.Period 1: Started Time is 07:30, Shutdown Time is 18:30, Running Mode is Cool, Temperatureis 24°C and Fan Speed is High.If the air conditioner is running within the set period of the Weekly Timer and another controldevice - as for example a wired controller - is active, the air conditioner will run according tothe commands of the control device, till next Period (Period 2) of the Weekly Timer.• Tuesday foresees 1 Period of setting: in fact, as no Running Mode is set in Period 2, (Mode =Off), Timer function is not active.
f) Others
Period 1
Monday
Time on = 07:30Time off = 18:00Mode = CoolTemp. = 24°CFan Speed = High
Time on = 07:30Time off = 18:00Mode = CoolTemp. = 24°CFan Speed = Low
Time on = 18:30Time off = 19:00Mode = OffTemp. =Fan Speed =
Time on = 18:30Time off = 21:00Mode = Fan onlyTemp. =Fan Speed = High
Time on = 21:30Time off = 23:30Mode = CoolTemp. = 24°CFan Speed = High
Tuesday
Period 2 Period 3 Period 3
- 21 -
ERROR CODES
Error Codes on the Weekly Centralized Controller’s display
Code
EA
EB
EC
ED
EE
EF
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
00#
01#
P0
Content
Compressor overcurrent error
Inverter module protection
Freshness fault
Fault protection of the Outdoor Unit
Water-level detection fault
Other faults
Phase-sequence error or phase-failure
Communication fault
T1 sensor fault
T2 sensor fault
T2B sensor fault
Zero-crossing detection error
EEPROM error
Indoor fan-speed out of control
Communication fault between main board and display board
Communication fault between the network interface module and the main control board
Communication fault between the central controller and the network interface modulelo
Temperature protection of evaporator
P1 Anti-cold air or defrosting protection
P2 High temperature protection of condenser
P3 Temperature protection of compressor
P4 Temperature protection of exhaust pipe
P5 Discharge high-pressure protection
P6 Discharge low-pressure protection
P7 Over-voltage or under-voltage protection
P8 Compressor overcurrent error
PF Altre misure di protezione
Compressor discharge temp. sensor, T3 temp. sensor, T4 temp. sensor error
EC DECLARATION OF CONFORMITY
We TERMAL Srl - 14, Via della Salute - 40132 Bologna - Italy
DECLARE
under our sole responsibility that HOKKAIDO Product
Weekly-Timer Central Controller
• DTCWT - IHXR
conforms with the following directives:
• EMC Directive 89/336/EEC and its following 92/31 EEC by L.D. No. 476 dated Decdmber 4th, 1992.
• LV Directive 73/23 EEC and applied Standards EN 60335-2-40.
NOTES
TERMAL Srl14, Via della Salute
40132 Bologna - ItalyTel. +39.051.41.33.111Fax +39.051.41.33.112www.termalgroup.com
Due to on-going technological development of the products by the Manufacturer, we reserve the right to vary the technical specifications at any time without notice.