WF-300®XL

OPERATION AND MAINTENANCE INSTRUCTIONSWF-540 Issue 04 DF528

MMD/1.19

• Ideal for Task lighting and work activities in a hazardous area

• ATEX and IECEx approved for Zone 1 and 21 explosive gas and dust atmospheres.

• High power ‘fitted for life’ LED light source

• High quality, even, ultra-wide angle LED light, reduces shadows and enhances visibility

• Medium angle flood beam

• Safe/Optimal Voltage Indication “SOVI” to ensure safe certified

operation.

• ATEX/IECEx Approved Floodlite Protection Accessories available

LinkExTM WF-300®XL LED Floodlite features

WOLF SAFETY LAMP COMPANYSaxon Road Works, Sheffield, S8 0YA, UKT: +44 114 255 1051 F: +44 114 255 7988 E: [email protected] W: www.wolfsafety.com

BETR

IEBS- U

ND

WA

RTU

NG

SAN

LEITUN

G

Page 2: WF-300 XL - ELSPRO · 21 LL-311 Gland M20 x 1.5mm 1 (+1 LinkEx Versions) 22 WF-495 M20 stopping plug 1 23 WF-550 Certification label and bracket are specific to the individual 1

EU Declaration of ConformityThe Wolf WF-300XL LED Floodlite meets all relevant provisions of the 2014/34/EU Explosive Atmospheres (ATEX Equipment) Directive by virtue of the issued EU Type Examination Certificate, demonstrating compliance with all relevant Harmonised Standards and Essential Health and Safety Requirements.The Wolf WF-300XL LED Floodlite is a high performance lightweight portable floodlight, constructed from marine grade aluminium with a powder coated finish and toughened glass lens. The Floodlite is Group II, Category 2 equipment for use in zone 1, 2, 21 and 22 potentially explosive gases, vapours, mists and dusts where the T4 temperature class/118°C maximum surface temperature permits. The Floodlite is certified for use with the Wolf accessories listed in these instructions

Approval Code:

II 2GD Ex eb mb op is IIC T4 Gb Ex tb op is IIIC T118°C Db. Ta = -40°C to +55°C or Ta = -40°C to +40°C when the WF-462 optional Protection Cover is fitted

Ensure any replacement cable is rated for the lower ambient temperature the product will be used in and a +80°C minimum upper rating.

EU Type Examination Certificate: CML18ATEX3372X

Notified Body: SGS FIMKO OY. P.O. Box 30 (Särkiniementie 3) 00211 HELSINKI. Finland

Notified body number: 0598

Harmonised standards applied:- EN60079-0:2012+A11: 2013, EN60079-7:2015, EN60079-18:2015, EN60079-28:2015 EN60079-31:2014.

Ingress protection level IP66 & IP67 to EN60529:1992.

Wolf WF-300XL LED Floodlites are manufactured in accordance with the 2014/30/EU EMC Directive to the following standards:- EN 55015:2013+A1 2015, EN 61000-3-2:2014, EN 61000-3-3:2013, EN 61547:2009.

Alex Jackson – Managing Director, Wolf Safety Lamp Company Ltd

IECEx Scheme CertificationCertificate Number: IECEx CML 18.0198XEx eb mb op is IIC T4 GbEx tb op is IIIC T118°C DbTa = -40°C to +55°C or Ta = -40°C to +40°C when the WF-462 optional Protection Cover is fittedIEC Standards applied: IEC60079-0:2011, IEC60079-7:2015, IEC60079-18:2014, IEC60079-28:2015 & IEC60079-31:2013.

SPECIAL CONDITIONS OF USE (X CONDITION)The Floodlite enclosure coated surfaces are non-conducting and may generate an ignition-capable level of electrostatic charge under certain extreme conditions. The equipment shall not be installed in a location where the external conditions are conductive to the build-up of electrostatic charge on these non-conductive surfaces. Additionally, the equipment shall only be cleaned with a damp cloth.The Floodlite can be fitted with a protective cover (WF-462), when fitted the maximum ambient temperature lowers from +55°C to +40°C. Use only Wolf supplied accessories.

Equipment Use • Check the rating label to ensure the Floodlite is

suitable for the supply provided, ambient temperature present and the environmental conditions.

• It is the user’s responsibility to ensure there is no potential difference between the earth supply to a Floodlite unit and the local earth in the work area. Where this is not possible the equipment should be securely earth bonded to metalwork in the immediate vicinity of where the Floodlite is being used. A flexible cable is recommended (6mm2 minimum, no more than two metres long), connected to the earth grounding point on the Floodlite enclosure. Floodlites must be de-energised during connection or disconnection of the local earth bond.

• Safe/Optimal Voltage Indicator (SOVI). The Wolf WF-300XL LED Floodlite incorporates SOVI technology to highlight to the user if the product is operating outside of the certified maximum and recommended minimum voltage range.

• The diagram below represents the SOVI function, it demonstrates that when the voltage is not within the “Safe/Optimal Voltage” the light output will change from a constant uninterupted beam to a pulse.

• The Floodlite is approved with a range of protective consumable accessories that are designed to protect and extend its maintained lifecycle. These accessories should be replaced when the light output is obscured.

• When the polycarbonate Floodlite Lens Guard (WF-421) is fitted to the Floodlite, the end user must ensure that this is suitable for the atmosphere the Floodlite will be used in.

• Inspect seals. Silicone seals are used in the construction of the lamp. Where conditions could include exposure to chemicals that may react with silicone, seek further advice.

Wolf WF-300XL LED Floodlite Operation & Maintenance InstructionsPlease Retain – Read Before Use

SAFE NON-OPTIMAL VOLTAGE

SOVI FUNCTION DIAGRAM

LIGHTOUTPUT

UNSAFE VOLTAGESAFE/OPTIMAL VOLTAGE0V

NORMAL

DIM

OFF

0V90V – 100V18V – 19V

264V50V

WF-300XLHWF-300XLL

TERMINAL CONNECTING

30mmMax 8mm

30mmMax 8mm

ACCESSORIES

WIRING SCHEMATIC 18-50V

WIRING SCHEMATIC 90-264V

Ensure _< 1mm conductor exposed from the metal of the terminal throat

0.5-0.7Nm

Magnet Kit WF-545

Mesh cover WF-480

Protection cover kit WF-462

Note:

II 2GD Ex eb mb op is IIC T4 Gb (-40°C≤Ta≤+40°C). Ex tb op is IIIC T118°C Db

Lens Guard Kit WF-421

Wolf WF-300XL LED Floodlite (Flutlichtstrahler)Betriebs- und WartungsanleitungBitte aufbewahren - Vor Gebrauch lesenEG-Konformitätserklärung

Der Wolf WF-300XL LED Floodlite erfüllt alle einschlägigen Bestim-mungen der Richtlinie 2014/34/EG über die Verwendung in explo-sionsgefährdeten Bereichen (ATEX-Geräte) gemäß der ausgestellten EU-Baumusterprüfbescheinigung, die die Einhaltung aller relevanten harmonisierten Normen und grundlegenden Gesundheits- und Sicher-heitsanforderungen nachweist.

Der Wolf WF-300XL LED Floodlite ist ein leistungsstarker, leichter und tragbarer Flutlichtstrahler aus seewasserbeständigem Aluminium mit pulverbeschichteter Oberfläche und gehärteter Glaslinse. Der Flood-lite ist ein Gerät der Gruppe II, Kategorie 2 für die Verwendung in den Zonen 1, 2, 21 und 22 mit explosionsfähigen Gasen, Dämpfen, Nebeln und Stäuben bei Temperaturklasse T4 mit Oberflächentemperaturen von 118°C. Der Floodlite ist für die Verwendung mit dem in dieser An-leitung aufgeführten Zubehör von Wolf zugelassen.

Zulassungskennzeichnung:

Stellen Sie sicher, dass jede Ersatzleitung für die niedrigere Umge-bungstemperatur, in der das Produkt verwendet wird, sowie für die Obergrenze von +80°C geeignet ist.

EG-Baumusterprüfbescheinigung:Sira17ATEX3035X

Überwachungsstelle:SGS Baseefa Ltd., Rockhead Business Park, Staden Lane, Buxton, SK17 9RZ, UK,Überwachungsstellen-Nr.: 1180Angewandte harmonisierte Normen: EN60079-0:2012+A11: 2013, EN60079-7:2015, EN60079-18:2015, EN60079-28:2015EN60079-31:2014.

Schutzart IP66 und IP67 gemäß EN60529:1992.

Die Wolf WF-300XL LED Floodlites werden in Übereinstimmung mit der EMV-Richtlinie 2014/30/EU nach folgenden Normen hergestellt:- EN 55015:2013+A1 2015, EN 61000-3-2:2014, EN 61000-3-3:2013, EN 61547:2009.

Alex Jackson – GeschäftsführerWolf Safety Lamp Company Ltd.

II 2GDEx eb mb op is IIC T4 GbEx tb op is IIIC T118°C Db.Ta = -40°C bis +55°C oder Ta = -40°C bis +40°C, wenn die optionale WF-462 Schutzabdeckung angebracht ist

IECEx ZertifizierungZertifikat-Nummer: IECEx SIR 17.0013XEx eb mb op is IIC T4 GbEx tb op is IIIC T118°C Db IP67Ta = -40°C bis +55°C oder Ta = -40°C bis +40°C, wenn die optionale WF-462 Schutzabdeckung angebracht ist.Angewandte IEC-Normen: IEC60079-0:2011, IEC60079-7:2015, IEC60079-18:2014, IEC60079-28:2015 und IEC60079-31:2013.

BESONDERE BEDINGUNGEN („X-Bedingungen“)Die beschichteten Oberflächen des Floodlite-Gehäuses sind nicht leit-fähig, können jedoch unter bestimmten extremen Bedingungen zum Auftreten zündfähiger Entladungen führen. Das Gerät darf nicht in Um-gebungen eingesetzt werden, in denen die äußeren Umstände den Auf-bau elektrostatischer Ladungen auf den nicht leitfähigen Oberflächen begünstigen. Das Gerät darf nur mit einem feuchten Tuch gereinigt werden.Der Floodlite Flutlichtstrahler kann mit einer Schutzabdeckung (WF-462) versehen werden. Ist diese montiert, reduziert sich die maximale Umgebungstemperatur von +55°C auf +40°C. Verwenden Sie nur das von Wolf gelieferte Zubehör.

Geräteverwendung• Überprüfen Sie anhand des Typenschildes, ob der Floodlite für die

vorhandene Stromversorgung, die vor Ort herrschenden Umge-bungstemperaturen und -bedingungen geeignet ist.

• Es obliegt dem Nutzer dafür zu sorgen, dass keine Potentialdiffe-renz zwischen dem Erdanschluss einer Floodlite und der Erdung vor Ort im Arbeitsbereich besteht. Ist dies nicht möglich, sollte das Gerät in unmittelbarer Nähe des Einsatzortes des Floodlite Flut-lichtstrahlers sicher mit der Metallkonstruktion verbunden sein. Es wird eine flexible Leitung empfohlen (mindestens 6mm², nicht über zwei Meter Länge), das an den Erdungspunkt am Floodlite-Gehäu-se angeschlossen wird. Die Floodlites müssen bei Anschluss oder Trennung der Erdverbindung vor Ort in spannungsfreiem Zustand sein.

• Safe Optimal Voltage Indicator (SOVI, Anzeigegerät für sichere, optimale Spannung) . Der Wolf WF-300XL LED Floodlite ist mit der SOVI Technologie ausgestattet, die dem Nutzer anzeigt, wenn das Produkt außerhalb des zugelassenen maximalen und empfohle-nen minimalen Spannungsbereichs betrieben wird.

• Nachstehendes Schaubild verdeutlicht die SOVI-Funktion. Bei einer Spannung außerhalb des „sicheren, optimalen Spannungs-bereichs“ wechselt die Lichtstrahlung von konstant auf pulsierend.

• Der Floodlite ist für eine Reihe von Sicherheits-Verbrauchsmate-rialien zugelassen, die eine optimale Lebensdauer des Produkts gewährleisten. Das Zubehör ist bei schlechter werdender Lichtleis-tung auszutauschen.

• Falls die Floodlite Linsen-Schutzabdeckung aus Polycarbonat (WF-421) am Floodlite montiert ist, muss der Nutzer sicherstellen, dass dieser für die Atmosphäre geeignet ist, in welcher der Flood-lite betrieben wird.

FUNKTIONSSCHAUBILD SOVI

SICHERE, NICHT OPTIMALE SPANNUNG NICHT SICHERE SPANNUNGSICHERE, OPTIMALE SPANNUNG

LICHT-LEIS-TUNG

SCHWACH

AUS

NORMAL

- Änderungen und Irrtum vorbehalten -

Page 3: WF-300 XL - ELSPRO · 21 LL-311 Gland M20 x 1.5mm 1 (+1 LinkEx Versions) 22 WF-495 M20 stopping plug 1 23 WF-550 Certification label and bracket are specific to the individual 1

SPARE PARTS

Item Part Part Description Quantity No. No.

1 WF-552 Painted rear casting + seal and retaining bolts 12 WF-572 Painted front cover assembly, complete with glass 13 WF-554 Glass Lens, Seal and bracket pads 14 WF-586 18-50V LED Driver 1 (2 needed per Floodlite)5 WF-592 90-264V LED Driver 1 (2 needed per Floodlite)6 WF-558 LED Panel, Thermal pad and fixing screws 1 (2 needed per Floodlite)7 WF-562 6 way -4mm2 Terminal Block, & 2 QB links and fixing screws 1 8 WF-564 4 way -4mm2 Terminal Block, and fixing screws 19 WF-587 LED Driver Retention Bracket (18-50V) 110 WF-589 LED Driver Retention Bracket (90-264V) 111 WF-560 Complete Driver Assembly Inc. Bracket and terminals (18-50V) 112 WF-570 Complete Driver Assembly Inc. Bracket and terminals (90-264V) 113 WF-584 Floodlite Enclosure Seal 114 WF-585 Floodlite Glass Seal 115 WF-576L Internal Screw and Sticker Set 18-50V AC/DC 116 WF-576H Internal Screw and Sticker Set 90-264V AC 117 WF-566 Internal Earth/Grounding wire set 118 WF-568 External Earth Stud 119 WF-590 Bridle Fixing Kit 120 WF-582 Frame & Bridle (No fixings incl.) 121 LL-311 Gland M20 x 1.5mm 1 (+1 LinkEx Versions)22 WF-495 M20 stopping plug 123 WF-550 Certification label and bracket are specific to the individual 1 product, contact your authorised Wolf supplier for replacement.

Contact your authorised Wolf supplier for replacement cables, plugs or link socket components.

7

8

4 5

9 10

11 12

Torque0.5 – 0.6Nm

Torque3.6 – 3.8Nm17

• If connecting a large number of Floodlites check for SOVI indication on all the lamps in the string. Guidance on lamp connection and extensions can be found at www.wolfsafety.com

• This product is Class 1 equipment and must be earthed. Floodlites are supplied as standard with 3 core earthed supply cables. Where the user specifically requires a 24 volt SELV Floodlite with 2 core cable (+ve and -ve) / a 2 pole plug, the Floodlite must be used with a separate connection to earth via the external earth grounding point.

• All Floodlites have terminal blocks suitable for incoming cables for up to 4mm² conductor capacity.

• Ex “e” certified Increased Safety terminal blocks must have all terminals fully tightened down even if a conductor is not fitted. On all terminal blocks, tighten screws to 0.5-0.7Nm.

• ATEX/IECEx approved cable glands must be used and be suitable for the type of cable used. Any unused cable entries should be blanked off with a suitable ATEX/IECEx approved stopper plug to maintain a minimum IP67 rating and temperature rating as marked on the label.

• Floodlites and cable should be inspected prior to each use for visible signs of damage. Particular attention should be paid to gland and socket entries. Damaged lamps should be removed from the work area and repaired before being put back in service.

• WF-300XL LinkEx Floodlites fitted with a wired ATEX/IECEx socket, must have the socket covers closed when not in use to maintain IP rating of the socket housing.

PHOTOBIOLOGICAL SAFETY.Floodlites are risk group 1 – No photobiological hazard under normal behavioural limitations.

TECHNICAL DATA

ELECTRICAL DATA

MAINTENANCE

• Isolate the Floodlite from the mains supply and allow to cool before carrying out any maintenance work.

• IMPORTANT. No modifications are permitted to the Floodlites, all spare parts must be purchased from the manufacturer, unauthorized modifications or spare parts will invalidate certification.

• Portable Appliance testing must be carried out to IEC, EN standards to the correct rating i.e. 250V DC for 18-50V versions and 500V DC for 90-264VAC versions. Live and neutral cables must be shorted together and the voltage applied between earth and this connection.

FRONT COVERRemove the front cover by unscrewing the four socket head retaining bolts. Release the Earth connecting wire by releasing the locking spade connnection in the floodlite by depressing the tab on the connector and pulling away. Perform repairs/maintenance as necessary. To reassemble follow the above points in reverse order. Take care not to trap/crush wires and ensure the seal is in good condition.*The Certificate label and serial number are fitted to the front cover, therefore do not interchange the front covers with other WF-300XL Floodlites. See internal body label for serial number reference.

CHANGING CABLE OR SOCKETSee diagrams overleafDisconnect the input cable, release cable from input gland. Check the gland seal is in good condition, fit the new part(s) and re-assemble the product by following the stated procedure in reverse order.

CHANGING LED PANELSSee diagrams overleafEach LED panel can be removed by unscrewing four socket head bolts and the wiring terminations. Discard the old panel and replace with a new one by following the removal procedure in reverse. A new thermal pad must be fitted on replacement under the LED panel as shown in the exploded diagram.

CHANGING LED DRIVERSSee diagrams overleafUnscrew the internal & external wiring terminations from the six & four way terminal blocks and remove the driver retention bracket by unscrewing the two bolts. One or both drivers can be replaced. To reassemble follow the above points in reverse order.

CHANGING GLASS LENSSee diagrams overleafReplace the glass by unscrewing the six socket head screws securing the three retaining plates. Fit the new glass making sure strip gasket material is fitted between the glass and each retention plate.

FAULT FINDING

Risk of Shock

If a WF-300XL Floodlite fails to function, remove the product from service into a non hazardous area. Remove the cover and apply power to the Floodlite. Check the input voltage at the terminals is present and is the correct rating for the Floodlite. If the voltage is correct the check the output voltage to the LED panels, this should be 19V DC+/-1V. If this voltage is not present then the driver is faulty, if it is then the LED panel is faulty. Replace as necessary.

DISPOSAL OF WASTE MATERIALDisposal of packaging, Floodlite as well as LED panels and drivers should be carried out in accordance with national regulations (WEEE).

SPARE PARTSSee diagrams overleafThe Wolf Safety Lamp Co. Ltd has a policy of continuous product improvement. Changes in design details may be made without prior notice.

Enclosure Marine grade aluminium alloy with a powder coated finish.

Lens Toughened Glass

Light Source:

Type 36 x White High Power LEDs

Life 100,000+ hrs

Weight 7.3kg (excluding cable)

Model WF-300XLL WF-300XLH

Voltage 18-50V AC/DC 90-264V AC only

Freq Hz 50/60 50/60

Total Circuit Power

≤ 55 Watts ≤ 62 Watts

VA (AC) 84VA at 24V AC96VA at 42V AC104VA at 48V AC

N/A

• Wird eine größere Anzahl von Flutlichtstrahler eingesetzt, prüfen Sie, ob alle Flutlichtstrahler in der Reihe über die SOVI Funktion verfügen. Hinweise zum Anschluss der Strahler und der Verbin-dungskabel finden Sie unter www.wolfsafety.com

• Bei dem Produkt handelt es sich um ein Gerät der Klasse 1, das geerdet werden muss.

• Die Flutlichtstrahler werden standardmäßig mit 3-adrigen geerde-ten Netzanschlussleitungen geliefert. Wenn der Nutzer einen 24 Volt SELV-Floodlite mit 2-adriger Leitung (+ve und -ve) und 2-poli-gem Stecker benötigt, ist der Flutlichtstrahler mit einem separaten Erdanschluss über den externen Erdungspunkt zu verwenden.

• Alle Flutlichtstrahler verfügen über Klemmleisten für Zuleitungen bis zu 4 mm² Leiterquerschnitt.

• Bei Klemmleisten für „erhöhte Sicherheit“ Ex „e“ müssen alle Klemmen vollständig festgezogen sein, auch wenn kein Leiter ein-gelegt ist. Bei allen Klemmleisten sind die Schrauben mit 0,5 - 0,7 Nm anzuziehen.

• Es sind ATEX/IECEx-zugelassene und für den verwendeten Leitungstyp geeignete Kabelverschraubungen zu verwenden. Alle nicht verwendeten Leitungseinführungen sollten mit einem ent-sprechenden und nach ATEX/IECEx zugelassenen Blindstopfen verschlossen werden, um die auf dem Typenschild angegebene Schutzart IP67 einzuhalten.

• Die Flutlichtstrahler und Leitungen sollten vor jedem Gebrauch auf sichtbare Beschädigungen überprüft werden. Besonders ist hier auf die Leitungseinführungen und Einbausteckdosen zu achten. Beschädigte Lampen sind aus dem Arbeitsbereich zu entfernen und instand zu setzen, bevor sie wieder in Betrieb genommen werden.

PHOTOBIOLOGISCHE SICHERHEITFlutlichtstrahler gehören zur Risikogruppe 1 - und stellen bei normalem Verhalten des Nutzers im Gebrauch keine Gefährdung dar.

TECHNISCHE DATEN

Gehäuse Seewasserbeständige Aluminiumlegie-rung mit Pulverbeschichtung

Gehärtetes Glas

36 x leistungsstarke, weiße LEDs

100.000+ Std.

7,3 kg (ohne Leitung)

WF-300XLL

18 - 50 V AC / DC

50 / 60 50 / 60

≤ 50 Watt

84 VA bei 24 V AC 94 VA bei 42 V AC 104 VA bei 48 V AC

≤ 62 Watt

N/A

90 - 264 V nur AC

WF-300XLH

Linse

Gewicht

Modell

Spannung

Frequenz Hz

Stromkreisleis-tung Gesamt

VA (AC)

Typ

LebensdauerLicht-quelle

ELEKTRISCHE DATEN

WARTUNG

Gefahr eines Stromschlags

• Trennen Sie die Flutlichtstrahler vom Netz und lassen Sie sie ab-kühlen, bevor Sie Wartungsarbeiten durchführen.

• WICHTIG. Die Flutlichtstrahler dürfen nicht modifiziert werden. Sämtliche Ersatzteile müssen vom Hersteller bezogen werden und unzulässige Änderungen oder nicht zugelassene Ersatzteile führen zum Erlöschen der Zertifizierung.

• Die Prüfung von tragbaren Geräten ist nach IEC- und EN-Nor-men mit der entsprechenden Nennspannung durchzuführen, d. h. 250 V DC für 18 - 50 V Modelle und 500 V DC für 90 - 264 V AC Modelle. Die Spannungsführenden und der neutrale Leiter sind kurzzuschließen. Dabei ist die Spannung zwischen Erde und diesem Anschluss anzulegen.

FRONTABDECKUNGEntfernen Sie die Frontabdeckung, indem Sie die vier Zylinderkopf-schrauben lösen. Ziehen Sie das Erdanschlusskabel heraus, indem Sie den Flachstecker des Flutlichtstrahlers durch Herunterdrücken und Abziehen der Anschlusslasche lösen. Führen Sie bei Bedarf Repa-ratur- und Wartungsarbeiten durch. Für den Wiederanschluss sind obige Punkte in umgekehrter Reihenfolge abzuarbeiten. Achten Sie darauf, dass keine Leitungen eingeklemmt/gequetscht werden und die Leitungsabdichtung intakt ist.

*Das Zertifizierungsetikett mit der Seriennummer befindet sich auf der Frontabdeckung, daher darf die Frontabdeckung nicht mit der von anderen WF-300XL Floodlites getauscht werden. Die Seriennummer befindet sich auf dem Etikett innen im Gehäuse.

AUSTAUSCH VON LEITUNGEN ODER EINBAUSTECKDOSENSiehe umseitige SchaubilderTrennen Sie die Zuleitung und nehmen die Leitung aus der Leitungs-einführung heraus. Prüfen Sie, ob die Leitungsdichtung intakt ist, montieren das neue Teil (die neuen Teile) und bauen das Produkt wie erläutert in umgekehrter Reihenfolge wieder zusammen.

AUSTAUSCH DER LED-PANELSSiehe umseitige SchaubilderJedes LED-Panel lässt sich durch Lösen der vier Innensechskant-schrauben sowie der Leitungsanschlüsse herausnehmen. Entsorgen Sie das alte Panel und montieren das neue LED-Panel in der umge-kehrten Reihenfolge der bei der Entnahme beschriebenen Vorgehens-weise. Beim Austausch muss eine neue Wärmeleitmatte unter dem LED-Panel angebracht werden (siehe Explosionszeichnung).

AUSTAUSCH DER LED-TREIBERSiehe umseitige SchaubilderSchrauben Sie die Leitungsanschlüsse innen und außen aus den 6- und 4-Wege-Klemmleisten heraus und entfernen Sie die Halterung der Treiber durch Lösen beider Schrauben. Sie können einen oder beide Treiber austauschen. Für den Wiederanschluss sind obige Punkte in umgekehrter Reihenfolge abzuarbeiten.

AUSTAUSCH DER GLASLINSESiehe umseitige SchaubilderBeim Tausch der Glasabdeckung lösen Sie die sechs Innensechskant-schrauben, die zur Befestigung der drei Haltebügel dienen. Beim An-bringen der neuen Glasabdeckung achten Sie darauf, das Dichtband zwischen Glasplatte und Haltebügel aufzulegen.

FEHLERSUCHE

Falls ein WF-300XL Floodlite nicht mehr ordnungsgemäß funktioniert, nehmen Sie das Gerät in einem nicht explosionsgefährdeten Bereich außer Betrieb. Lösen Sie die Abdeckung und schließen den Flutlicht-strahler ans Netz an. Prüfen Sie, ob die Eingangsspannung an den Klemmen anliegt und den für den Flutlichtstrahler vorgegebenen Nenn-werten entspricht. Bei korrekter Spannung prüfen Sie die Ausgangs-spannung an den LED-Tafeln. Diese sollte 19 V DC +/-1 V betragen. Falls dieser Spannungswert nicht erreicht wird, ist der Treiber und somit das LED-Panel defekt. Bei Bedarf austauschen.

ENTSORGUNG VON ABFALL/ALTMATERIALDie Entsorgung des Verpackungsmaterials, des Flutlichtstrahlers sowie der LED-Panels und -Treiber ist in Übereinstimmung mit den nationa-len Bestimmungen (WEEE) durchzuführen.

ERSATZTEILESiehe umseitige SchaubilderDie Firma Wolf Safety Lamp Co. Ltd setzt auf eine kontinuierliche Pro-duktverbesserung. Technische Änderungen ohne vorherige Ankündi-gung vorbehalten.

- Änderungen und Irrtum vorbehalten -

Page 4: WF-300 XL - ELSPRO · 21 LL-311 Gland M20 x 1.5mm 1 (+1 LinkEx Versions) 22 WF-495 M20 stopping plug 1 23 WF-550 Certification label and bracket are specific to the individual 1

19

19

2

317

6

4 5

Torque 3.6 – 3.8Nm

Torque 2Nm

Torque 2Nm

Torque 2.4 – 2.6Nm

Torque 2.4 – 2.6Nm

Torque2.4 – 2.6Nm

Torque 0.8-1.0Nm

On 90-264v versions Driver Earth wires

terminate here

17

2

90-264v versions of WF-300XL LinkEx Floodlite can be fitted with a wired ATEX/IECEx socket

on this arm of the frame to enable the Floodlite to be linkable to another Floodlite and set up a

string of lights from a single power source. Contact your authorised Wolf supplier for

replacement link socket parts.

1

20

20

13

14

23

18

21

22Threadlock medium strength blue

Drehmoment 2 Nm

Drehmoment 2 Nm

Bei 90 - 264 V Modellen:Die Erdungsleiter der Treiber

sind hier angeschlossen.

Die 90 - 264 V Modelle WF-300XL LinkEx Floodlite können mit einer leitungsgebundenen ATEX/IECEx-Dose an

diesem Gestellarm versehen werden, so dass man meh-rere Flutlichtstrahler mit nur einer Stromquelle in Reihe zusammenschließen kann. Für Informationen zu Ersatz-

teilen für Anschlussdosen wenden Sie sich bitte an Ihren autorisierten Wolf-Händler.

Drehmoment 0,8 - 1,0 NmDrehmoment

2,4 - 2,6 Nm

Drehmoment 2,4 - 2,6 Nm

Drehmoment 2,4 - 2,6 Nm

Gewindesicherung, mittelfest, blau

Drehmoment 3,6 - 3,8 Nm

- Änderungen und Irrtum vorbehalten -

Page 5: WF-300 XL - ELSPRO · 21 LL-311 Gland M20 x 1.5mm 1 (+1 LinkEx Versions) 22 WF-495 M20 stopping plug 1 23 WF-550 Certification label and bracket are specific to the individual 1

EU Declaration of ConformityThe Wolf WF-300XL LED Floodlite meets all relevant provisions of the 2014/34/EU Explosive Atmospheres (ATEX Equipment) Directive by virtue of the issued EU Type Examination Certificate, demonstrating compliance with all relevant Harmonised Standards and Essential Health and Safety Requirements.The Wolf WF-300XL LED Floodlite is a high performance lightweight portable floodlight, constructed from marine grade aluminium with a powder coated finish and toughened glass lens. The Floodlite is Group II, Category 2 equipment for use in zone 1, 2, 21 and 22 potentially explosive gases, vapours, mists and dusts where the T4 temperature class/118°C maximum surface temperature permits. The Floodlite is certified for use with the Wolf accessories listed in these instructions

Approval Code:

II 2GD Ex eb mb op is IIC T4 Gb Ex tb op is IIIC T118°C Db. Ta = -40°C to +55°C or Ta = -40°C to +40°C when the WF-462 optional Protection Cover is fitted

Ensure any replacement cable is rated for the lower ambient temperature the product will be used in and a +80°C minimum upper rating.

EU Type Examination Certificate: CML18ATEX3372X

Notified Body: SGS FIMKO OY. P.O. Box 30 (Särkiniementie 3) 00211 HELSINKI. Finland

Notified body number: 0598

Harmonised standards applied:- EN60079-0:2012+A11: 2013, EN60079-7:2015, EN60079-18:2015, EN60079-28:2015 EN60079-31:2014.

Ingress protection level IP66 & IP67 to EN60529:1992.

Wolf WF-300XL LED Floodlites are manufactured in accordance with the 2014/30/EU EMC Directive to the following standards:- EN 55015:2013+A1 2015, EN 61000-3-2:2014, EN 61000-3-3:2013, EN 61547:2009.

Alex Jackson – Managing Director, Wolf Safety Lamp Company Ltd

IECEx Scheme CertificationCertificate Number: IECEx CML 18.0198XEx eb mb op is IIC T4 GbEx tb op is IIIC T118°C DbTa = -40°C to +55°C or Ta = -40°C to +40°C when the WF-462 optional Protection Cover is fittedIEC Standards applied: IEC60079-0:2011, IEC60079-7:2015, IEC60079-18:2014, IEC60079-28:2015 & IEC60079-31:2013.

SPECIAL CONDITIONS OF USE (X CONDITION)The Floodlite enclosure coated surfaces are non-conducting and may generate an ignition-capable level of electrostatic charge under certain extreme conditions. The equipment shall not be installed in a location where the external conditions are conductive to the build-up of electrostatic charge on these non-conductive surfaces. Additionally, the equipment shall only be cleaned with a damp cloth.The Floodlite can be fitted with a protective cover (WF-462), when fitted the maximum ambient temperature lowers from +55°C to +40°C. Use only Wolf supplied accessories.

Equipment Use • Check the rating label to ensure the Floodlite is

suitable for the supply provided, ambient temperature present and the environmental conditions.

• It is the user’s responsibility to ensure there is no potential difference between the earth supply to a Floodlite unit and the local earth in the work area. Where this is not possible the equipment should be securely earth bonded to metalwork in the immediate vicinity of where the Floodlite is being used. A flexible cable is recommended (6mm2 minimum, no more than two metres long), connected to the earth grounding point on the Floodlite enclosure. Floodlites must be de-energised during connection or disconnection of the local earth bond.

• Safe/Optimal Voltage Indicator (SOVI). The Wolf WF-300XL LED Floodlite incorporates SOVI technology to highlight to the user if the product is operating outside of the certified maximum and recommended minimum voltage range.

• The diagram below represents the SOVI function, it demonstrates that when the voltage is not within the “Safe/Optimal Voltage” the light output will change from a constant uninterupted beam to a pulse.

• The Floodlite is approved with a range of protective consumable accessories that are designed to protect and extend its maintained lifecycle. These accessories should be replaced when the light output is obscured.

• When the polycarbonate Floodlite Lens Guard (WF-421) is fitted to the Floodlite, the end user must ensure that this is suitable for the atmosphere the Floodlite will be used in.

• Inspect seals. Silicone seals are used in the construction of the lamp. Where conditions could include exposure to chemicals that may react with silicone, seek further advice.

Wolf WF-300XL LED Floodlite Operation & Maintenance InstructionsPlease Retain – Read Before Use

SAFE NON-OPTIMAL VOLTAGE

SOVI FUNCTION DIAGRAM

LIGHTOUTPUT

UNSAFE VOLTAGESAFE/OPTIMAL VOLTAGE0V

NORMAL

DIM

OFF

0V90V – 100V18V – 19V

264V50V

WF-300XLHWF-300XLL

TERMINAL CONNECTING

30mmMax 8mm

30mmMax 8mm

ACCESSORIES

WIRING SCHEMATIC 18-50V

WIRING SCHEMATIC 90-264V

Ensure _< 1mm conductor exposed from the metal of the terminal throat

0.5-0.7Nm

Magnet Kit WF-545

Mesh cover WF-480

Protection cover kit WF-462

Note:

II 2GD Ex eb mb op is IIC T4 Gb (-40°C≤Ta≤+40°C). Ex tb op is IIIC T118°C Db

Lens Guard Kit WF-421

- Änderungen und Irrtum vorbehalten -

Arti-kel-Nr.

Teile-Nr. Beschreibung des Teils Menge

1

234

5

6

7

891011121314151617181920212223

WF-552

WF-572WF-554WF-586

WF-592

WF-558

WF-562

WF-564WF-587WF-589WF-560WF-570WF-584WF-585WF-576LWF-576HWF-566WF-568WF-590WF-582LL-311WF-495WF-550

Rückwärtiges Gehäuse, lackiert, mit Abdichtung und Befestigungs-schraubenLackiertes Frontabdeckungs-Set, inkl. GlasGlaslinse, Dichtung und Haltelaschen18 - 50 V LED-Treiber

90 - 264 V LED-Treiber

LED-Panel, Wärmeleitmatte und Befestigungsschrauben

6-fach 4mm² Klemmleiste, mit 2 QB Anschlüssen und Befestigungs-schrauben4-fach 4mm² Klemmleiste, mit BefestigungsschraubenLED-Treiber Klemmbügel (18 - 50 V)LED-Treiber Klemmbügel (90 - 264 V)Komplette Treiber-Baugruppe mit Bügel und Klemmen (18 - 50 V)Komplette Treiber-Baugruppe mit Bügel und Klemmen (90 - 264 V)Dichtung Floodlite-GehäuseFloodlite Glas-DichtungSchrauben- und Aufkleber-Set innen 18 - 50 V AC / DCSchrauben- und Aufkleber-Set innen 90 - 264 V ACInternes Masse/ErdungskabelsetExterner ErdungssteckerBefestigungsmaterial für U-HalterungTragegestell und U-Halterung (kein Befestigungsmaterial inbegriffen)Verschraubung M20 x 1,5mmM20 BlindstopfenDas Zertifizierungsetikett und die Halterung sind produktspezifisch, Ersatz ist über Ihren autorisierten Wolf-Händler erhältlich.

1

111 (je Flutlichtstrahler werden 2 benötigt)1 (je Flutlichtstrahler werden 2 benötigt)1 (je Flutlichtstrahler werden 2 benötigt)1

11111111111111 (+1 LinkEx Modelle)11

Bitte wenden Sie sich an Ihren autorisierten Wolf-Händler, wenn Sie Ersatz für Leitungen, Stecker oder Einbausteckdosen benötigen.

ERSATZTEILE KLEMMANSCHLUSS

SCHALTSCHEMA 18 - 50 V

SCHALTSCHEMA 90 - 264 V

ZUBEHÖR

Schutzabdeckungs-SetWF-462

Magnet-Set WF-545

Schutzgitter WF-480

Hinweis:

Drehmoment 0,5 - 0,6 Nm

Drehmoment 3,6 - 3,8 Nm

11 12

5

9

8

7

10

4

Es müssen mindestens ≤ 1mm Leiter vom Metall der Anschluss-öffnung freigelegt sein.

Schutzabde-ckungs-Set LinseWF-4210,5 - 0,7 Nm

Page 6: WF-300 XL - ELSPRO · 21 LL-311 Gland M20 x 1.5mm 1 (+1 LinkEx Versions) 22 WF-495 M20 stopping plug 1 23 WF-550 Certification label and bracket are specific to the individual 1

WF-300®XL

OPERATION AND MAINTENANCE INSTRUCTIONSWF-540 Issue 04 DF528

MMD/1.19

• Ideal for Task lighting and work activities in a hazardous area

• ATEX and IECEx approved for Zone 1 and 21 explosive gas and dust atmospheres.

• High power ‘fitted for life’ LED light source

• High quality, even, ultra-wide angle LED light, reduces shadows and enhances visibility

• Medium angle flood beam

• Safe/Optimal Voltage Indication “SOVI” to ensure safe certified

operation.

• ATEX/IECEx Approved Floodlite Protection Accessories available

LinkExTM WF-300®XL LED Floodlite features

WOLF SAFETY LAMP COMPANYSaxon Road Works, Sheffield, S8 0YA, UKT: +44 114 255 1051 F: +44 114 255 7988 E: [email protected] W: www.wolfsafety.com

• Ideal für Beleuchtung des Arbeitsum-feldes und Arbeiten in Gefahrenberei-chen

• ATEX- und IECEx-Zertifizierung für explosive Gas- und Staubatmosphä-ren der Zone 1 und 21

• Für die gesamte Gebrauchsdau-er ausgelegte, leistungsstarke LED-Lichtquelle

• Hohe und gleichmäßige LED-Licht-leistung mit breitem Abstrahlwinkel, geringe Schattenbildung und beste Ausleuchtung

• Flutlichtstrahl mit mittlerem Abstrahl-winkel

• Mit “SOVI” Funktion zur Anzeige der sicheren/optimalen Spannung für si-chere und zertifizierte Anwendung

• ATEX/IECEx-zertifiziertes Schutzzu-behör für Flutlichtstrahler erhältlich

Merkmale des LinkExTM WF-300®XL LED Floodlite