why is it better for your lab? - agilent · why is it better for your lab? steve miller ... project...
TRANSCRIPT
Why is it better for your lab? Steve Miller
Jon Welsh
Agilent Technologies Informatics Specialist
#5 - MUTE YOUR PHONE
Agenda
• What is OpenLAB? What are the products?
• What is Agilent doing with Chemstation and EZChrom?
• What is the new Architecture Options?
• Reporting
• New Integration package
Group/Presentation Title Agilent Restricted
Month ##, 200X
Capture, Organize, Collaborate • Smart, high productivity alternative
to paper notebooks • IP Protection and Compliance
Features • Simplifies and accelerates R&D • Smart Data Import and Dynamic
Forms • Simple Web Based Client
• Analytical Request Module
OpenLAB ELN Electronic Lab Notebook
What is: Agilent OpenLAB Software Portfolio
WorkStations, Client-Server • ChemStation, EZChrom Elite
• Multi-Vendor • OpenLAB ECM Intelligent Reporter
• Regulated and Non-Regulated Modes
• Web-Based Options including iPad and iPhone monitoring
OpenLAB CDS Chromatography Data System
Scientific Data Management • Data Archiving
• Instrument Vendor Neutral • Time Stamp/Audit Trail
• Report Capture • Viewers, Filters, Converters
• E-Signatures • Regulatory Compliance • TNF Conversion (LTDA)
OpenLAB ECM Data Management
OpenLAB ECM
Partners, Customers Scientific
Research Project
Management
Instrument Results
Corporate Records
SOPs
Reference Material Lab Instrumentation Training Records
GLP Records
Scientific Data Management System
Process Data
Collect, maintain, utilize, share, and archive all electronic records
What is OpenLAB ELN ?
A Web-based ELN which enables you to go paperless…
• Document, manage and analyze across multiple disciplines with a single solution
• Search and collate disparate data sources into single experiment with high level of traceability
• Reduce cycle times with integrated workflow processing and improve lab efficiency
• Integrate with existing information systems
Resulting in…
• Improved efficiency and data quality • More secure Intellectual Property protection
OpenLAB CDS Win 7 32 and 64 bit Win 2008 Server Provide users a Common CDS Experience
Page 6
Goal: One CDS Data
Product
Classical EZChrom
Cassical ChemStation
OpenLAB EE/CS editions
June 2012
OpenLAB Data Analysis
Today Same Front
End
Same Intelligent Reporting Engine
OpenLAB CDS Vision Where we stand today
Uniform Drivers (RC.NET)
Uniform Reporting
(Intelligent Reporter)
Uniform Data Analysis
OpenLAB CDS A.01.01 C.01.01 ChemStation Edition
A.04.01 EZChrom Edition
Page 7
ChemStation B.04.0x EZChrom 3.3.x
June 2012
OpenLAB Data Analysis
Today
October 2012 Today
Today
OpenLAB Data Analysis Benefits Works with OpenLAB EZChrom & ChemStation
Page 8 June 2012
OpenLAB Data Analysis
ChemStation
EZChrom
Works with both platforms! • A single platfor to learn
• Use the same integration, calculation, calibration and
reporting accross your laboratory
What is the new OpenLAB Architecture ?
Group/Presentation Title Agilent Restricted
Month ##, 200X
OpenLAB CDS - Workstations
OpenLAB CDS – Networked Workstations
OpenLAB CDS – Distributed System
What’s New - OpenLAB Control Panel
Central point for: • Launching ChemStation
& EZChrom instruments • “Lab-at-a-Glance” view • Administration of users,
storage and instruments • User privileges/user security • Administrative reports New look and feel: • Intuitive • Easy-to-use Support and troubleshooting: • Central access to all config and
log files Page 13
Lab-at-a-glance view EZChrom and ChemStation
in one application
Scalability for instrument management and administration
OpenLAB CDS Highlights Agilent Restricted
March 21, 2011
OpenLAB CDS - What’s New?
• ChemStation on OpenLAB Shared Services architecture – Central Administration in OpenLAB Control Panel – Configuring user privileges, roles and security (logon/password) – Full Scalability from workstation to enterprise – Remote Instrument Access and buffered data acquistion over the network – Instrument Status information for the whole lab from your 3G phone or iPad
OpenLAB CDS Highlights Agilent Restricted
March 21, 2011 Page 14
Lab-at-a-glance view
Roles & Privileges
ChemStation roles and privileges are managed in OpenLAB Control Panel and can be used without OpenLAB ECM.
Page 15
OpenLAB CDS Highlights Agilent Restricted
March 21, 2011
OpenLAB CDS ChemStation Edition - What’s New?
• More intuitive ChemStation workflows – Dedicated views for routine/reprocessing and interactive, flexible research workflows – New Review view for fast reporting without reprocessing – Sequence Containers are now called Result Sets – Results Sets now contain a copied Master Method now called the Sequence Method as well as the
Sequence and Intellegent Report Templates – Original Master Method and Sequence Templates remain unchanged – Sequence data is not overwritten – Data Recalculation and Reprocessing are both available in Data Analysis – Zip files containing everything in a sequence
• Improved integration with OpenLAB ECM – Flexible R&D workflows compatible with sequence-based storage in OpenLAB ECM
OpenLAB CDS Highlights Agilent Restricted
March 21, 2011 Page 16
Usability: Introducing workflows – How?
Review View • New ChemStation Review View • Uses Intelligent Reporter to show results
Data Analysis View Recalculation Mode - Flexible
• Recalculate peak results in the navigation table with one or several different methods • Shortcut to recalculate all data in the navigation table with a single method • Manually step through navigation table or use auto-stepping to review
Reprocessing Mode - Traceable • Reprocess the sequence with different method(s) to update or modify calibration • Add new or changed methods to result set and reprocess the whole or partial sequence • Store and manage all result and method revisions with sequence/result set
NEW
NEW
Page 17
OpenLAB CDS Highlights Agilent Restricted
March 21, 2011
Review View
Page 18
Key Benefit: Preview or print reports without reprocessing and get your reports 10 times faster!
Select report template(s) and data-files (any) and
get immediately answers on complete
experiments!
OpenLAB CDS Highlights Agilent Restricted
March 21, 2011
OpenLAB CDS Highlights Agilent Restricted
March 21, 2011 Page 19
Recalculation Mode
Any method can be loaded from the tree
“autostepping” toolbar
Switch between Recalculation and Reprocessing Mode
“Recalculate” menu
Key benefits: quickly apply multiple methods to a self-defined set of runs
OpenLAB CDS Highlights Agilent Restricted
March 21, 2011 Page 20
Reprocess Mode New tree with current sequence methods; quickly add master methods to the result set
Key benefit: Easy way to reprocess and recalibrate complete sequence
Switch between modes “sequence reprocessing” toolbar
OpenLAB CDS ChemStation Edition - What’s New?
OpenLAB CDS Highlights Agilent Restricted
March 21, 2011 Page 21
Page 22
OpenLAB CDS Highlights Agilent Restricted
March 21, 2011
OPENLAB CDS EZCHROM EDITION
What’s new
Group/Presentation Title Agilent Restricted
Month ##, 200X Page 23
OpenLAB CDS EZChrom Edition - What’s New? • Major Architecture change
– New Windows Communication Foundation (WCF) using TCP/IP as protocol – More IT-friendly with no DCOM needed for instrument control. – Increased responsiveness in the application – Web Server required for Control Panel
• Merging of OpenLAB and EZChrom Elite – Additional permissions and security for EZChrom customers – Optional NEW data container file-based or ECM-based (SSIZip). The container can contain data,
sequence results, acquisition method, acquisition sequence and templates. • OpenLAB Control Panel
– More permissions for more control with users/groups and roles – Project settings
• Intelligent reports – New Report tool with much more power
• E-signature of data • GC Usability Enhancements
– GC Configuration (Column dimensions, ALS syringe size, Pressure units, Gases, Aux setup) now part of the method
– Multiple Injector support: Configure many sources and select with method
OpenLAB CDS Highlights Agilent Restricted
March 21, 2011 Page 24
OpenLAB CDS EZChrom Edition Data Organization
• Configure which Result Set (data container) to use and whether to include method and/or templates.
• Add runs to a Result Set.
Page 25
OpenLAB CDS Highlights Agilent Restricted
March 21, 2011
GC Usability Enhancements
GC Configuration now part of the method
• Column dimensions • ALS syringe size • Pressure units • Gases • Aux setup
Multiple Injector support • Configure many sources
and select with method
Page 26
Page 27
OpenLAB CDS Intelligent Reporting
Page 28
New custom reporting application –embedded into OpenLAB CDS
Easily include graphics such as your company logo Intuitive report
template generation with drag & drop and interactive report preview functionality
Pre-configured report items (tables, graphics, matrices) make it easy to generate custom reports
Intelligent Reporting: •Include limit checks into report
•Decision-based result representation (pass/fail)
Embedded custom calculation functionality to calculate final results – here %label claim
Page 29
OpenLAB CDS Intelligent Reporting
Page 30
OpenLAB CDS Intelligent Reporting
Page 31
OpenLAB Data Analysis Benefits Benefits
Page 32
From sample to result Faster • Smart streamlining with both OpenLAB EZChrom & ChemStation • Now you can quickly process & review large sets of data
Results with less effort Easier • Intuitive (“flat”), adaptable user inteface allows for easer navigation • Supports HPI specific workflows, applications & calculations
Tools to improve your performance Smarter • Revolutionary manual integration tool for faster reviewing • Integrated with Intelligent Reporter to give you results the way you need them
June 2012
OpenLAB Data Analysis
OpenLAB Data Analysis Benefits Ease-of-use
Page 33 June 2012
OpenLAB Data Analysis
“Flat” intuitive User Interface
Function Ribbon
The Perfect User Interface • Intiutive Interface
• Usergroup validated • Direct access to main functions
• MS Standard Ribbon • Less dialog boxes to close
OpenLAB Data Analysis Benefits Ease-of-use: Improved Data Selection
Page 34 June 2012
OpenLAB Data Analysis
Easily Select your data! • Select data from multiple folders
• Works with EZChrom & ChemStation data
• Load sequence as whole or select specific runs from the sequence
Improved Data Selection
OpenLAB Data Analysis Benefits Ease-of-use: Improved Data Viewing
Page 35 June 2012
OpenLAB Data Analysis
Viewing made easy! • Overlay / Compare 100’s of
signal • Work with LC and GC data at the
same time • Use multiple methods and data
sets in parallel
Improved Data Navigation
OpenLAB Data Analysis Benefits See what you need to see
Page 36 June 2012
OpenLAB Data Analysis
Automated Scaling • Always focus on the right stuff
• Scale automatically to a peak • Scale by ignoring peaks
• Scale to baseline • No more zooming per sample!
OpenLAB Data Analysis Benefits Orginize your screen
Page 37 June 2012
OpenLAB Data Analysis
Configurable Lay-outs to meet
workflow specific needs
Orginize your screen • Design your own layout
• Match your screen layout with the task you are performing
• Comes with 4 predefined layouts
OpenLAB Data Analysis Benefits It’s Fast! Reprocess 100 samples in ~5 seconds!
Page 38 June 2012
OpenLAB Data Analysis
It is Fast! • 100 samples takes ~5 sec
• 40 x faster than ChemStation • 10 x faster than EZChrom
OpenLAB Data Analysis Benefits Easy Method Development
Page 39 June 2012
OpenLAB Data Analysis
Method development made Easy! • All settings in one screen
• See it all; compunds, groups, ISTD
• Powerful identification capabilities
• Flexible compound grouping
OpenLAB Data Analysis Benefits Unique Peak integration tool
Page 40 June 2012
OpenLAB Data Analysis
Unique integration tool! • Fastest peak integration
adjustment ever! • One instead of 30+ icons
• Makes sample review fun again!
Revolutionary one-click Manual
Integration Tool for fast review!
OpenLAB Data Analysis Benefits Infinitely Better Reporting!
Page 41 June 2012
OpenLAB Data Analysis
Intelligent Reporting • OpenLAB Intelligent Reporter
• Fully integrated • A true Powerhouse Solution
Questions
Page 42
OpenLAB ECM
Partners, Customers Scientific
Research Project
Management
Instrument Results
Corporate Records
SOPs
Reference Material Lab Instrumentation Training Records
GLP Records
Scientific Data Management System
Process Data
Collect, maintain, utilize, share, and archive all electronic records
Collecting and Protecting Forensics Data Agilent Restricted
June, 2007
Centrally Store and Protect All Data Content Management Capabilities
Manage and organize ALL electronic content regardless of source
• Analytical Data • Chromatography results • Photographs and images • PDF files and forms • Scanned paper files • Email • Microsoft Office files • Electronic reports • ANY electronic content
OpenLAB ECM ICP-MS Chemstation
• Compliance and GxP Overview • ICP-MS ChemStation OpenLAB ECM: System Overview
• Compliance with 21 CFR Part 11 –Data Security –Data Integrity
–Data Traceability • ICP-MS Validation Services
• Summary
Confidentiality Label
New Action in MassHunter Quant
Chemstation “C” and MS Chemstation “E” have seamless integration to ECM
ICP-MS MassHunter Solution
ECM Workgroup installation and qualification (IQ/OQ) • Services for a total price of $10,000 (current price $13,400) • SMA for ECM priced at $3,000 (current price $3,700) • Only for the ICPMS bundle • Promotional Discount capped at 10% - allows us to get to $18,000 • The $18,000 price is a short term promotional price to incent customers –
may be extended based on strong activity
September 4, 2012 47
ICPMS Bundle ECM SW $7,000 Install & Qualification $10,000 SMA $3,000 Total $20,000