Page 1: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

Wind farm wake verification Kurt S. Hansen

Senior Scientist DTU Wind Energy – Fluid Mechanics

Support by

Copenhagen, 10 February 2015

Page 2: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 2

• Introduction wind turbine wakes; • Participants & models; • Results Simple wakes and moderate spacing; Wakes for small spacing and speed recovery; Wakes for variable spacing Wind farm clusters; Wake behind a large wind farm;

• Discussion & acknowledgements;

Outline

Page 3: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 3

Introduction wind turbine wakes

1. Basic wake deficit - pairs of wind turbines; a) Power deficit; b) Peak deficit vs turbulence;

2. Rows of turbines; a) Constant spacing (small or large); b) Speed recovery due to ”missing” turbines;

3. Wind farms with variable spacing; 4. Park efficiency; 5. Wind farm clusters = Farm – Farm wake

Page 4: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 4

Wake deficit between pairs of wind turbines

Definition of power deficit = 1 – power ratio = 1 – Pwake/Pfree

Ambient

Page 5: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 5

Wake deficit for turbines with constant spacing

Increased sector, ∆

Page 6: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 6

Definition of park efficiency

Definition of park efficiency ηpark :

ηpark = <Pi>/Pref

where

Pref = undisturbed turbines <Pi>; i=3..8

otherwise: Pref = <Ptop 3>

Park efficiency at 8 m/s & ∆=5°

Page 7: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 7

1. Horns Rev I WF: 80 x Vestas V80 á 2MW Regular layout with 7D spacing; Well know dataset from other benchmarks;

2. Lillgrund WF: 48 x SWP-2.3-93 m Very dense wind farm with 3.3 and 4.3 D fixed spacing; Missing ”turbines” => speed recovery analysis;

3. Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance

of 33 diameters; 4. Alpha Ventus WF: 6 x REpower 5 MW & 6 x AREVA 5 MW

Introduction to wind farms

Page 8: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 8

Horns Rev I offshore wind farm, DK

Photographer: Christian Steiness. 12 February 2008 at 13.00

80 x Vestas V80-2MW-80 m

Page 9: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 9

Lillgrund offshore wind farm, SE

Photo: Kurt S. Hansen 2012.02

2 ”missing” turbines 48 x SWP-2.3-93m

Page 10: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 10

Wind farm cluster: Rødsand II WF/Nysted WF

by courtesy of E•ON

Nysted WF

Rødsand II

Page 11: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 11

Basic park model types 1) Engineering models eg. NOJ or CGL Fast and easy to implement Widely used (WASP, WindPro,..)

2) Linierized flow solver e.g. FUGA Fast compared to the CFD models

3) CFD models Complexity and speed is medium to slow

Benchmark participants and models

Models Affiliation Horns Rev WF Lillgrund WF Rødsand II WF Rødsand II/Nysted WFSCADA/BA DTU Wind Energy/K.S.Hansen x x x (x)NOJ/BA DTU Wind Energy/misc xNOJ/GU DTU Wind Energy/misc x xNOJ/BA DTU Wind Energy/A. Pena x x xWASP/NOJ Indiana Uni/RB xGCL/BA DTU Wind Energy/misc xGCL/GU DTU Wind Energy/misc x xGCL(GU) CENER/JS.Rodrigo x xFUGA/SO DTU Wind Energy/S. Ott x x xDMW DTU Wind Energy/TJ.Larsen xAD/RANS UPORTO/J.L. Palma x x xCRESflowNS CRES/ J. Prospathopoulos x x xFarmFlow ECN Wind Energy/J.G Scheepers x x x xCFDWake CENER/B.G. Hevia x xRANS/fPC DTU Wind Energy/P.vd Laan x xAinslie RES-LTD/T.Young x xWRF/UPM Ciemat/A.Palomares xMesoscale DTU Wind Energy/P.Volker x

BA=Bin averaged & GU=Gaussian Uncertainty

Page 12: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 12

Results from Horns Rev benchmark

Peak deficit, ∆=5°

Page 13: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 13

Results from Horns Rev benchmark

i) ∆=5°

ii) ∆=30°

i) ∆=5°

ii) ∆=30°

Page 14: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 14

Horns Rev park efficiency; 0 - 360°

∆ = 5°

Page 15: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 15

• First EERA-DTOC benchmark included 11 models, which has been implemented succesfull;

• The basic flow cases displayed some sector size dependent differences;

• The park efficiency case demonstrated that the models were able to cover a complete wind farm.

Horns Rev benchmark - discussion

Page 16: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 16

Lillgrund offshore wind farm – 3.3 D spacing

Wdir=120±15°

Page 17: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 17

Lillgrund offshore wind farm – 3.3 D spacing

2 missing ”turbines”

Wdir=120±15°

Decreased deficit -due to speed recovery

Page 18: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 18

Lillgrund Park efficiency: 0 - 360°

Page 19: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 19

• All models handles 3.3 and 4.3D spacing well; • All models handles the speed recovery due to ”missing”

turbines; • All models ware able to simulate the park efficiency

for 0 - 360° inflow; • The simulated ∆AEP demonstrates a variation of ±3%

compared to the measured value;

Lillgrund benchmark - discussion

Page 20: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 20

Rødsand II wind farm – variable spacing

Wdir = 280±10°

Page 21: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 21

Rødsand II wind farm – park efficeincy

Page 22: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 22

Measured wind farm cluster effects.

Page 23: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 23

Measured wind farm cluster effects.

Page 24: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 24

Offshore wind farm cluster effects.

Model inflow Uhub=8 m/s WDIR=97°

Page 25: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 25

Cluster effect for U=8 m/s; WD=97°

SCADA

WRF

RANS

RANS

RANS

ENG ENG

FUGA

WRF/MESO

Page 26: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 26

FarmFlow

AD/RANS

Cluster modeling results, U=8 m/s; WD=87°

RANS/fPC

Page 27: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 27

AD/RANS

RANS/fPC FarmFlow

Simulation results from modeling the combined effect of Nysted & Rødsand II WF

Cluster modeling results, U=8 m/s; WD=97°

Page 28: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 28

Park efficiency comparison

Problem with our inflow reference

Page 29: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 29

Cluster effects - discussion

• Quantification of the cluster effect is not possible due to lack of measurements and park asymmetry.

• The benchmark have demonstrated that both size and location of the distinct deficit zones - caused by the Nysted wind farm have been predicted quite well by the models.

• The benchmark concludes that several models were able to handle the clustering of wind farms.

Page 30: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 30

Wake measurements behind Alpha Ventus WF

40 minutes boat trip 10-15D

@FINO 1

Wind speed profile of EERA-DTOC TEST Case 04

Page 31: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 31

Alpha Ventus wind farm wake verification Results and discusion

IWES ship lidar AD/RANS WAsP/DTU FLaP/IWES

Normalized wind speed at 90 m height based on 40 minutes averaged inflow conditions

• The comparison represent 40 minutes of measurements and

model results; • The magnitude of the deficit can be simulated in average within

a tolerance of 7% for 40 m and 90 m (=hub) heights, but with increasing deviations above hub height;

• The position of the wakes from the simulations do match well the initial wakes from the AREVA turbines.

• The modeled Senvion wakes deviates from the measured, probably caused by a change in the wind direction (5-10°).

Page 32: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 32

This work was supported by the EU EERA-DTOC project nr. FP7-ENERGY-2011/n 282797. We acknowledge both E•ON, DONG Energy and Vattenfall for the access to the SCADA data from the Rødsand II, Nysted, Horns Rev and Lillgrund offshore wind farms.

Acknowledgements

Page 33: Wind farm wake verification · Rødsand: 90 x SWP-2.3-93 m Variable spacing based on 5 x 18 turbines on archs; Nysted WF: 72 x Bonus-2.3-82 m separated by a distance of 33 diameters;

EERA-DTOC Final Conference, Copenhagen, 10th March 2015 33

Acknowledgement to the participants

• Ana Palomares; CIEMAT, ES • Bibiana Hevia & Javier Rodrigo; CENER, ES • Gerard Schepers; ECN, NL • Tom Young; RES-LTD • José Palma & Vitor Gomes; CEsA, Univ Porto, PT • John Prospathopoulos; NTUA, GR • Rebecca Barthelmie, Indiana Univ. USA • Søren Ott, Patrick Volker, Alfredo Penã, Tuhfe Göçmen,

Torben Larsen, Paul van der Laan ; DTU Wind Energy • Julia Gottschall, Gerrit Wolken-Möhlmann IWES, DE • Hauke Beck, Juan José Trujillo, Univ. Oldenburg, DE