wires & cables - siechem

1
Wires & Cables Area Cond.Min. No.of Wires Thickness of EBXL / XLPE Insulation (Nom.) Approx Overall diameter Approx.Net Wt.of Cable Max.D.C Resistance at 20 deg.C Current Rating For EBXL -XLPE Cables (125°C) Direct in Ground In Duct In Air Current Rating For Chemically Cured XLPE Cables (90°C) Short Circuit Rating for 1 sec Direct in Ground In Duct In Air Sq.mm Nos mm mm Kg/Km Ω/KM Dimension of Arm strips Thickness of Outer Sheath mm mm Cu Cu Cu Cu Cu Cu Cu Product Construction Wires & Cables üConductor : Annealed Plain copper conductor complying with BS 6360 üInsulation : Electron Beam Cross Linked Polyethylene 120°C üArmour : GI Strips üJacket : PVC Complying with BS 6746 Siechem 2 Core APC Conductor EBXL - XLPE 120°C Insulated GI Strips Armoured PVC Sheathed 600/1000 V Power cable as per BS 5467 Application Features Technical Data üOperating Temperature : -15°C to +120°C High Insulation resistance at elevated temperature üShort Circuit Temperature : 280°C üBending radius (min) : 12 x Cable dia üRated Voltage :600/1000 V üTest Voltage : 3.5 kV for 5 mins. üSpecification : BS 5467 Part Number 749E3002 749E3202 749E3402 749E3702 749E3802 749E4102 749E4202 749E4402 749E4602 749E4802 749E4902 25 35 50 70 95 120 150 185 240 300 400 7 7 19 19 19 37 37 37 61 61 61 0.9 0.9 1.0 1.1 1.1 1.2 1.4 1.6 1.7 1.8 2.0 1.6 1.7 1.8 1.9 2 2.1 2.2 2.4 2.5 2.5 2.5 28.7 32.6 37.3 42.5 48.0 52.8 58.4 64.8 72.1 79.4 89.7 1274 1623 2068 2642 3341 4015 4813 5830 7148 8620 10895 3.6 5.0 7.1 10.0 13.6 17.1 21.4 26.4 34.3 42.9 57.1 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.9991 0.0754 0.0601 0.0470 198 234 273 343 408 451 511 576 660 745 803 178 211 255 309 368 417 472 530 606 683 770 173 203 281 317 387 432 495 576 680 770 872 152 180 210 264 314 347 393 443 508 573 618 137 162 196 238 283 321 363 408 466 525 592 133 156 216 244 298 332 381 443 523 592 671 0.8 X 4 0.8 X 4 0.8 X 4 0.8 X 4 0.8 X 4 0.8 X 4 0.8 X 4 0.8 X 4 0.8 X 4 0.8 X 4 0.8 X 4 üTransmission and distribution of Power Industrial units üCommercial and residential places ü Indoor and outdoor uses üCable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables. üElectron Beam Cross Linked. üEnhanced Mechanical, Electrical, Thermal & Weathering properties. üSoldering iron resistant üResistance to corona effect. üEasy jointing & termination üBetter resistance to most chemicals & acids üLow direct electric losses. üHigh current carrying capacity. Siechem 2 Core APC Conductor EBXL - XLPE 120°C Insulated GI Strips Armoured PVC Sheathed 600/1000 V Power cable as per BS 5467 Cable conforming to IEC 60502 & VDE-0271 also available according to customer requirement. 749E Catalogue No www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 34 CM/L-6819184 IS : 7098 (Pt.1) IS : 7098 (Pt.1) OHSAS 18001 AS 9100 ISO 45001 ISO 9001 ISO 14001

Upload: others

Post on 16-Oct-2021

22 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Wires & Cables - Siechem

Wires & Cables

Area

Cond.Min.No.ofWires

Thicknessof EBXL /

XLPEInsulation

(Nom.)

ApproxOverall

diameter

Approx.NetWt.ofCable

Max.D.CResistanceat 20 deg.C

Current RatingFor EBXL -XLPECables (125°C)

Directin

Ground

Current RatingFor Chemically Cured XLPE Cables (90°C)

ShortCircuitRating

for 1secDirectin

Ground

Thicknessof PVCInner

Sheath

Dimensionof

ArmWire

Thicknessof

OuterSheath

Area

Cond.Min.No.ofWires

Thicknessof EBXL /

XLPEInsulation

(Nom.)

ApproxOverall

diameter

Approx.NetWt.ofCable

Max.D.CResistanceat 20 deg.C

Current RatingFor EBXL -XLPECables (125°C)

Directin

Ground

InDuct

InAir

Current RatingFor Chemically Cured XLPE Cables (90°C)

ShortCircuitRating

for 1 secDirect

inGround

InDuct

InAir

Sq.mm Nos mm mm Kg/Km Ω/KM

Dimensionof

Armstrips

Thicknessof

OuterSheath

mm mm Cu Cu Cu Cu Cu Cu Cu

Product Construction

Wires & Cables

üConductor : Annealed Plain copper conductor complying with BS 6360 üInsulation : Electron Beam Cross Linked Polyethylene 120°CüArmour : GI StripsüJacket : PVC Complying with BS 6746

Siechem 2 Core APC Conductor EBXL - XLPE 120°C Insulated GI Strips Armoured PVC Sheathed 600/1000 V Power cable as per BS 5467

Application

Features

Technical Data

üOperating Temperature : -15°C to +120°C High Insulation resistance at elevated temperature üShort Circuit Temperature : 280°CüBending radius (min) : 12 x Cable diaüRated Voltage :600/1000 VüTest Voltage : 3.5 kV for 5 mins.üSpecification : BS 5467

PartNumber

749E3002

749E3202

749E3402

749E3702

749E3802

749E4102

749E4202

749E4402

749E4602

749E4802

749E4902

25

35

50

70

95

120

150

185

240

300

400

7

7

19

19

19

37

37

37

61

61

61

0.9

0.9

1.0

1.1

1.1

1.2

1.4

1.6

1.7

1.8

2.0

1.6

1.7

1.8

1.9

2

2.1

2.2

2.4

2.5

2.5

2.5

28.7

32.6

37.3

42.5

48.0

52.8

58.4

64.8

72.1

79.4

89.7

1274

1623

2068

2642

3341

4015

4813

5830

7148

8620

10895

3.6

5.0

7.1

10.0

13.6

17.1

21.4

26.4

34.3

42.9

57.1

0.727

0.524

0.387

0.268

0.193

0.153

0.124

0.9991

0.0754

0.0601

0.0470

198

234

273

343

408

451

511

576

660

745

803

178

211

255

309

368

417

472

530

606

683

770

173

203

281

317

387

432

495

576

680

770

872

152

180

210

264

314

347

393

443

508

573

618

137

162

196

238

283

321

363

408

466

525

592

133

156

216

244

298

332

381

443

523

592

671

0.8 X 4

0.8 X 4

0.8 X 4

0.8 X 4

0.8 X 4

0.8 X 4

0.8 X 4

0.8 X 4

0.8 X 4

0.8 X 4

0.8 X 4

üTransmission and distribution of Power Industrial unitsüCommercial and residential placesü Indoor and outdoor usesüCable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables.

üElectron Beam Cross Linked.üEnhanced Mechanical, Electrical, Thermal & Weathering properties.üSoldering iron resistantüResistance to corona effect.üEasy jointing & terminationüBetter resistance to most chemicals & acidsüLow direct electric losses.üHigh current carrying capacity.

Siechem 2 Core APC Conductor EBXL - XLPE 120°C Insulated GI Strips Armoured PVC Sheathed 600/1000 V Power cable as per BS 5467

Cable conforming to IEC 60502 & VDE-0271 also available according to customer requirement.

749E

Catalogue No

www.siechem.com

All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.

34

CM/L-6819184

IS : 7098 (Pt.1)IS : 7098 (Pt.1)

OHSAS 18001

AS 9100

ISO45001

ISO 9001

ISO 14001