TECHNICAL SPEZIFICATIONVERSION 1.0 / LAST UPDATED 02.2019
WOOD GASIFIER V 3.90 &CHP ECO 165 / 180 HG
2
CONTENT
GENERAL INFORMATION ............................................................................................... 3
1. INTRODUCTION ....................................................................................................... 4
2. TECHNICAL DATA ..................................................................................................... 5
3. SERVICE AND MAINTENANCE ................................................................................... 6
4. CONDITIONS AT THE LOCATION ............................................................................... 6
5. INSTALLATION OF THE CHP ...................................................................................... 7
6. SCOPE OF DELIVERY AND INTERFACES ..................................................................... 8
7. SERVICES PROVIDED BY THE CUSTOMER ................................................................ 11
8. SETUP EXAMPLE .................................................................................................... 12
9. PHOTOS OF THE PLANT .......................................................................................... 14
IMPRINT ...................................................................................................................... 15
RESERVATION .............................................................................................................. 15
3
GENERAL INFORMATION
PRELIMINARY REMARKS
• We continuously improve our plants, therefore technical changes are reserved. The illustrations may differ slightly from the actual plant.
• Burkhardt GmbH does not offer any guarantee for errors and the up‐to‐dateness and accuracy of
the standards, guidelines and directives specified.
• Burkhardt GmbH does not assume responsibility for the adherence to the permit and the corresponding guidelines, standards and directives of the work performed by the customer, which is to be performed according to the specifications and/or in coordination with Burkhardt GmbH.
• Do not copy or pass on this planning document to third parties without the authorisation of
Burkhardt GmbH.
• Should you have any further questions, please do not hesitate to contact us. INTENDED USE This plant is used to generate electricity and a proportion of heat from wood pellets. Only operate it according to its intended use, the applicable regulations, and with all control functions and monitoring functions
as intended in its original condition without unauthorised changes in perfect technical condition with the provided auxiliary supplies
Only Burkhardt GmbH or personnel specifically instructed and trained for the plant may assemble, in‐stall, commission and service the wood gasifier. Otherwise, Burkhardt GmbH does not assume any liabi‐lity.
4
1. INTRODUCTION
The Burkhardt wood gasifier V 3.90, together with the combined heat and power plants ECO 165 HG (wood gas spark ignition) or the ECO 180 HG (wood gas pilot injection), generates electrical and thermal energy from wood pellets. By gasifying the wood pellets and using the product gas in an internal combustion engine with combined heat and power, the energy contained in the raw material is optimally utilised.
Auxiliary power
Ventilation / radiation losses
Useful output thermal
Wood gas (CO, H2, …)
Useful output electrical
Useful output thermal
Waste gas / ventilati‐on‐ / radiation losses
Wood chips, coke / ash
Operating materials (oils filters, used oil, cooling water)
Condensate
Pellets
5
2. TECHNICAL DATA
Model: V3.90 with ECO 165 HG an V3.90 with ECO 180 HG Operating principle: Updraught direct‐current gasification with stationary fluidised bed
Overall power plant V3.90 with ECO 165 HG V3.90 with ECO 180 HG
Electrical output: 165 kW 180 kW Thermal output: 260 kW 270 kW Flow / return temperatures: 95°C / 70°C 95°C / 70°C
Wood gasifier
Type: V3.90 Thermal output: 70 kW Fuel: Pellets according to EN Plus A1; Din EN ISO 17225‐2 Pellets consumption: 0.67 kg/kWel (110 kg/h) 0.61 kg/kWel (110 kg/h) Power self‐supply: approx. 6 kW Weight: approx. 5500 kg Dimensions: 5280 mm x 2470 mm x 3000 mm (L x W x H) Voltage supply: 3 x 400/230 V; 50 Hz; 32 A
CHP
Type: ECO 165 HG ECO 180 HG Electrical output: 165 kW 180 kW Thermal output: 190 kW 200 kW Fuel: Wood gas Wood gas + pilot oil Pilot oil consumption: ‐ < 5 ltr/h Power self‐supply: approx. 2 kW Weight: approx. 4640 kg Dimensions: 3760 mm x 1730 mm x 2600 mm (L x W x H) Voltage supply: 3 x 400/230V; 50 Hz; 32 A Emissions: see data sheet Engine Manufacturer: MAN Type: D26 Rotation speed: 1500 1/min Displacement: 12,4 ltr Number of cyclinders: 6 Operating principle: Four‐stroke Otto engine with
turbocharger Four‐stroke pilot injection gas engine with turbocharger
Synchronous generator Manufacturer: Leroy‐Somer Type: LSA 46.3 L10 Output: 199 kW Frequency: 50 Hz Voltage: 400 V
6
3. SERVICE AND MAINTENANCE
Daily tasks (time needed approx. 1h)
Inspection of the gas values, pressures and tem‐peratures (3 x per day ‐ possible via remote access)
Visual inspection for possible leaks, contamina‐tions, defects and of the reactor fill level (1 x per day at the plant)
Replace ash big bag (as required) Replace dust container (as required)
Weekly tasks (time needed approx. 1h)
Wood gasifier customer service
Every 4‐6 weeks (time needed approx. 1h)
Evacuate gas reactor and remove slag Clean wood gasifier
Every 500 hours of operation (time needed approx. 1h)
CHP service: oil change (interval can vary, depen‐ding on the lubricating oil system), adjust valves
Every 1000 hours of operation (time needed approx. 1h)
CHP service: oil change (interval can vary, depen‐ding on the lubricating oil system) , filter change
4. CONDITIONS AT THE LOCATION
Place requirement for the wood gasifier: Installation area: 9.70 m x 5.00 m (incl. service and maintenance area) Minimum room height: 5.50 m Place requirement for the CHP: Installation area: 7,85 m x 4,18 m (incl. service and maintenance area) Minimum room height: 2,85 m Operating temperature: ideal: 15°C up to 25°C Room for wood gasifier: max. 35°C Room for CHP: max. 40°C Internet connection for remote access Speed:
Download: min. 2 Mbit/s Upload: min. 1 Mbit/s
7
5. INSTALLATION OF THE CHP
Built cell Consultation with Burkhardt
GmbH for the exact construction planning
Drywall cell Consultation with Burkhardt
GmbH for the exact construction planning
Burkhardt concrete cell Soundproof engine room, com‐
pletely piped and wired; including all necessary components Dimensions: 8380 mm x 2980 mm x 3300 mm
Burkhardt sound insulating cab‐inet
Soundproof cabinet for CHP with removable side parts, completely wired with ventilation on top Dimensions: 4860 mm x 1734 mm x 2750 mm
8
6. SCOPE OF DELIVERY AND INTERFACES
9
10
11
7. SERVICES PROVIDED BY THE CUSTOMER
Planning and approval of the trades, according to legal regulations, guidelines and standards at
the place of fulfilment
Fire protection
Infrastructure
Fuel storage including fuel supply
Fuel supply to the wood gasifier, if this is not part of the scope of delivery
Hydraulic integration of wood gasifier into the heat distribution network, including insulation
Electrical and network cabling from terminal box Burkhardt according to standard
Internet connection for remote access
12
8. SETUP EXAMPLE
Top view:
13
Side view:
14
9. PHOTOS OF THE PLANT
15
IMPRINT
Publisher:
Burkhardt GmbH ‐ Energie‐ und Gebäudetechnik Kreutweg 2 92360 Mühlhausen (Germany)
Photographs and plans:
Property of Burkhardt GmbH including all rights
Disclaimer:
This brochure is a planning tool and contains general infor‐mation. Despite careful editing, we can offer no guarantee for the accuracy of the data and no legal claims can be deducted from the brochure. All rights, including those of reprinting ex‐cerpts and of photographic reproduction, are reserved.
RESERVATION
Burkhardt GmbH is continuously working on the further development of all plants. Please understand that changes of the technology as well as the delivery scope regarding form, equipment and technology are possible at any time. It is therefore not possible to derive claims from the data and descriptions of the planning documents. All data refer to the proper operation of the plants. Reprint, reproduction or translations, even in extracts, is not permitted without the prior written ap‐proval of Burkhardt GmbH. All rights according to the copyright law remain expressly reserved to Burkhardt GmbH. Burkhardt GmbH reserves the right to change any part of these planning documents at any time. Burk‐hardt GmbH does not give any warranty.
Last updated 02.2019 – 13/02/2019
BURKHARDT GMBHKREUTWEG 2
92360 MÜHLHAUSENGERMANY
TEL +49 9185 9401 0FAX +49 9185 9401 50
E-MAIL [email protected]
www.burkhardt-group.com