SR-IOV enables a new generation of NICs with multiple PCI Functions:◦ Each function operates as an independent NIC.◦ The functions actually share an external physical port.◦ Example: Neterion X3100.Direct PCI Function assignment provides Native performance.◦ While maintaining Hypervisor, Dom0/DomD and GOS control.◦ Using the same drivers for the Native OS no matter which

Hypervisor is in use (or none).◦ Is not dependent on Native OS being SR-IOV aware.

Page 3: XS Boston 2008 Networking Direct Assignment

Multi-port NIC has multiple physical ports.◦ Or possibly simply multiple NICs.

Each port is a distinct PCI function.◦ Each PCI function can be directly assigned to a Guest.◦ Provides benefits of Native Driver usage

No virtualization penalty.Full features of native mode available.Single driver in the OS image.

But an entire port is a big thing to assign◦ Not enough space for physical ports and cables.◦ No granularity on assignment.◦ Bandwidth wasted if the assignee has nothing to send.

Page 4: XS Boston 2008 Networking Direct Assignment

Multi-queue NICs provide multiple independent queues within a PCI function.Native OS can use multiple queues itself:◦ CPU Affinity, QoS, Ethernet Priorities.DomD can utilize Guest Specific queues:But his is not true device assignment.◦ Backend must validate/translate each request (WQE/TxD).◦ Does not enable vendor’s native driver.

Which already knows how to use multiple queues.◦ Does not provide Function Level Reset.

Page 5: XS Boston 2008 Networking Direct Assignment

Fastpath operations are direct.Fastpaths are created/maintained by frontend/backend.Hardware specific code is required in both the Guest and DomD.Single-threaded control means entaglement between Guests.◦ Are resource handles

migratable?◦ No Function Level

Reset.

Page 6: XS Boston 2008 Networking Direct Assignment

Multi-function NICs present each external port as its own multi-queue NIC.Each PCI function can be directly assigned.Frame Forwarding and External Ports are shared.Sharing is resolved on the device:◦ subject to Policy from

Hypervisor, DomD and GOS.

◦ .

Page 7: XS Boston 2008 Networking Direct Assignment

This presentation is not a call to add support for multi-function NICs in Xen.◦ Because the support is already there.Xen, and the various GOSs, already have almost everything they need to support multi-function NICs.◦ Xen has PCI Function Delegation.◦ Xen has migration.◦ GOSs support bonding/teaming drivers.◦ GOSs support PCI device insertion/removal.

Page 8: XS Boston 2008 Networking Direct Assignment

Assignment of each PCI Function can enable direct networking support for Guests:Eliminating virtualization overhead.◦ To be precise: costs of virtualization have been offloaded.

Enabling a single driver in the OS image◦ Regardless of which Hypervisor is deployed (or none).

While still supporting migration.While still preserving Xen control.

Page 9: XS Boston 2008 Networking Direct Assignment

NIC presents itself as multiple PCIfunctions.◦ Xen can assign as many to each guest

as it wants to.Relies on an Address TranslationSolution◦ IOMMU is just the most likely solution.◦ GOS does not need to be IOMMU aware.Still needs to deal with more VMs than directly PCI Functions◦ Correct complements frontend/backend.Worse issue with h/w specific driver in guest◦ That’s not a bug. That’s a feature.Full L2+ switch functionality on NIC

No need for a “full switch”.

Page 10: XS Boston 2008 Networking Direct Assignment

This is not a bug. It is a feature.There already is a device specific driver in the Guest OS image.The vendor worked very hard to get it there.◦ And to get it tested, and certified.◦ There is already a distribution chain

Which customers strongly prefer.◦ It already integrates hardware capabilities with Native OS

requirements.

Page 11: XS Boston 2008 Networking Direct Assignment

With Direct Assignment Only one driver is needed per OS◦ No separate distribution, development,

testing or certification is required.◦ Driver is operationally identical in all

modes, not just a matter of packaging multiple drivers in one binary.◦ One Driver can be distributed with the OS

Image to work with any or no Hypervisor.

Page 12: XS Boston 2008 Networking Direct Assignment

Only the raw frame forwarding services are needed on the NIC.Typical switch/bridge design is already split between a frame forwarding engine and management/control plane processing.The latter is usually in a conventional processor that sits on the side of the frame forwarding hardware.◦ A “Level-3”/MF-NIC has a very powerful processor attached to it.◦ In fact the customer already paid for it.

Page 13: XS Boston 2008 Networking Direct Assignment

A Shared Device is a generic PCI device. A Generic PCI Function can be assigned without understanding it:◦ Or what services it provides.◦ What specific device model it is.◦ What driver is required.

Xen already supports this.There are other configuration issues that needto be addressed somewhere.◦ Xen may be involved here.

Page 14: XS Boston 2008 Networking Direct Assignment

There are other shared configuration issues to be resolved:◦ On-chip resources must be allocated, but only the device needs to

know how this is done.◦ Ethernet device can only set one link state◦ Load sharing between the VNICs. Who gets to transmit how much?

Some of these may already be addressed by device independent Xen and/or Network Management◦ Rate shaping.◦ Uplink physical link configuration.

Page 15: XS Boston 2008 Networking Direct Assignment

Neither the Hypervisor or DomD needs to be involved.◦ The Shared Device and its PCI Function Drivers can implement

their own solution.◦ The device already knows how to talk with each VF Driver, and

what VFs are active.

DomD can control things it already knows:◦ MAC Address of VNIC ports.◦ VLAN Membership.

But DomD does not need to deal with new device specific controls.◦ All required logic can be implemented in device specific drivers

and/or network management daemons.

Page 16: XS Boston 2008 Networking Direct Assignment

Many methods possible◦ As though 802.1Q Bridge per external port.◦ Static defaults applied to be unmanaged switch

All VNIC MAC Addresses are Manufacturer supplied.◦ Privileged operations via the Native Driver

Enabled for DomD or stand-alone Native Drivers.◦ Combinations of the above.

Existing vif-bridge script could easily configure the vsport matching the VNIC for a directly assigned VIF.◦ It already has MAC Address and any VLAN ID.◦ Suggested naming convention: use PCI Function number to name

the Backend instance. Simplifies pairing with direct device.

Page 17: XS Boston 2008 Networking Direct Assignment

Migration Support using Guest OS Services

Page 18: XS Boston 2008 Networking Direct Assignment
Page 19: XS Boston 2008 Networking Direct Assignment

Frontend/Backend is kept in place and is always available.Direct Assignment is used for most important Guests◦ Each multi-function device will have a limit on how

many guests it can directly support.Native Driver talks directly to NIC through its own PCI function, if enabled.Bonding Driver uses frontend/backend if direct NIC is not available.

Page 20: XS Boston 2008 Networking Direct Assignment

Page Protection is not enough◦ Full Function Assignment requires true isolation of each PCI

Function.Protecting Pages is not enough.If a bad configuration register can hang the device then the functions are not truly independent.

◦ Some devices can only support direct Fastpaths.A direct fastpath does not address Driver Distribution Issues – It still requires two drivers◦ One when virtualized◦ One when running in native mode.Single-path for Slowpath Control means entangled Slowpaths◦ Untangling for migration not guaranteed to be easy.RDMA users complain about cost of slowpath operations. ◦ Virtualization will only make it worse.

Page 21: XS Boston 2008 Networking Direct Assignment

Directly Assigned Devices can be migrated using existing services:◦ GOS Device Bonding / Failover.

Including netfront/netback in the team enables migrations between platforms with different hardware.

◦ GOS support of PCI device insertion/removal.Including check-pointing of any stateful data in host memory.

Page 22: XS Boston 2008 Networking Direct Assignment

PCI Function assignment can support Multi-function NICs as generic PCI devices.◦ No special netfront/netback features are required.◦ The same features that enable direct assignment of entire

devices enable assignment of PCI Functions that actually share on-device resources.

Leverage work done for the Native Oss◦ Multi-queue.◦ Bonding/Failover.◦ Driver certification.◦ Driver distribution.Direct PCI Function assignment eliminates the overhead of network virtualization.

Page 23: XS Boston 2008 Networking Direct Assignment

Support PCI Function assignment.◦ It’s not just for special purpose devices.◦ It is well suited for high performance devices such

as NICs and Graphics adapters.Rely on Native OS Distribution Chain Work to standardize control of switching services whether in DomD or on the NIC.

Any Follow-up Questions?◦ [email protected]

5/14/2008Xen Summit Boston 2008

Page 24: XS Boston 2008 Networking Direct Assignment
Page 25: XS Boston 2008 Networking Direct Assignment

Additional Materialthat there will not be time for.

5/14/2008

Page 26: XS Boston 2008 Networking Direct Assignment

Multi-function NIC is unlikely to fully support all netfilter rules in hardware.When considering Direct Assignment:◦ Determine which netfilter rules are implemented by the

Multifunction NICs frame forwarding services.◦ Determine if the remaining netfilter rules can be trusted to DomU.◦ If there are filters that the hardware cannot implement, and

cannot be trusted to DomU, then don’t do the direct assignment.Direct Assignment complements frontend/backend.It is not a replacement.

Page 27: XS Boston 2008 Networking Direct Assignment

Auto-negotiate the uplinks.Divide resources evenly over configured/enabled PCI functions.Do not enable other VLANs.But any non-default configuration must be done via a privileged PCI function.

5/14/2008Xen Summit Boston 2008

Page 28: XS Boston 2008 Networking Direct Assignment

No performance penalty◦ GOS Driver is interacting with Device the same way it would

without virtualization.There is Zero penalty to the host.Multi-function NICs offload the cost of sharing.

◦ Frontend/Backend solutions always cost more:Address translation has non-zero cost. Copying even more.Latency penalty unavoidable.An extra step cannot take zero time.

Can support ANY service supported by the Native OS.◦ because the Native OS Driver sees the same resources.

Page 29: XS Boston 2008 Networking Direct Assignment

Frontend/Backend supplies excellent migration already◦ But requires a Hypervisor

specific frontend driver.Because it is the only universally supported solution it plays a critical role in enabling migration.

Page 30: XS Boston 2008 Networking Direct Assignment

Availability:◦ Is the driver installed in the Guest OS image?Efficiency:◦ Does the driver interfaces efficiently with the NIC?

Migration:◦ Can Guests using this Driver be migrated?

Flexibility:◦ Can new services be supported?

Page 31: XS Boston 2008 Networking Direct Assignment

Availability:◦ Excellent, NICs to be emulated are selected based on widespread

deployment.

Performance:◦ Terrible.

Migration:◦ not a problem.

Flexibility:◦ None. You’re emulating a 20th century NIC.

Page 32: XS Boston 2008 Networking Direct Assignment

Availability:◦ Good. But there is a lag problem on which frontend has made it

into the OS distribution.

Performance:◦ Tolerable.Migration:◦ not a problem.Flexibility:◦ New features require extensive collaboration.

Page 33: XS Boston 2008 Networking Direct Assignment

Availability:◦ Excellent. The same driver is used whether running natively or

under any Hypervisor.◦ NIC vendors already deal with OS distributions.

Performance:◦ Same as native.Migration:◦ Not really a problem, details to follow.

Flexibility:◦ Same as native.

Page 34: XS Boston 2008 Networking Direct Assignment

Multi-queue is a valuable feature◦ But it does not really compensate for being a Single PCI Function

Device.

Multi-function NICs are multi-queue NICs◦ But each queue is owned by a specific PCI Function.◦ It operates within the function specific IO MAP

Allowing GOS to communicate GPAs directly to the NIC.

Each PCI Function has its own◦ MSI-X.◦ PCI Config space.◦ Function Level Reset.◦ Statistics.

Page 35: XS Boston 2008 Networking Direct Assignment

More on GOS Enabled Migration

5/14/2008

Page 36: XS Boston 2008 Networking Direct Assignment

Requirement: device must be able to checkpoint any per-client stateful image in the client’s memory space.◦ Device is told when to checkpoint any Guest-specific stateful

information in the Guest memory image.◦ Migrating Guest check-pointed memory image is a known

problem that is already solved.

Device driver on new host is told to restore from check-pointed memory image.◦ Check-pointed image should be devoid of any absolute (non-VF

relative) references.◦ If this is not certain a “Migration Notice” is needed to enable the

driver to fix all absolute references.

Page 37: XS Boston 2008 Networking Direct Assignment

Same-to-same migration only requires checkpoint/restore of any Device state via VF Driver.◦ Once state is checkpointed in VM memory, the

Hypervisor knows how to migrate the VM.Many services do not require migration◦ Each VM implements one instance of a distributed

Service. Persistence is a shared responsibility.◦ Most Web servers fall in this category.GOS already provides failover between dissimilar devices through bonding drivers.

Page 38: XS Boston 2008 Networking Direct Assignment

Not all platforms have the same direct-access NICs, but same-to-same migration can be used anyway.Method A: post-migration makes right◦ Just do a Same-to-Same Migration anyway.◦ It will work

Of course because the actual device is missing on the new platform the re-activated instance will fail.Invoking existing device failover logic within the Guest.

◦ Possible Enhancement:Provide PCI Device removal event immediately on migration.

Page 39: XS Boston 2008 Networking Direct Assignment

Method B: migrate Same-to-same via netfront.◦ Fail the Directly Assigned device.◦ GOS will failover to the Frontend device.◦ Migrate same-to-same to the new target platform.

Which always can support netfront.◦ Enable the appropriate Directly Assigned device on the new

platform.◦ GOS is informed on newly inserted PCI Function.◦ GOS will failover to the preferred device as though it were being

restored to service.

Page 40: XS Boston 2008 Networking Direct Assignment

Frame Forwarding ServicesOn-chip “Switch”

5/14/2008

Page 41: XS Boston 2008 Networking Direct Assignment

Frame Forwarding Services needed◦ Directs incoming frames to the correct guest VNIC / PCI Function.◦ Provide internal VNIC-to-VNIC frame forwarding.◦ Provides VNIC to external port forwarding:

Some form of traffic shaping probably required.Must prevent forged source addresses.Must enforce VLAN membership.

Must work with Dom D “soft switch”◦ Must agree when to enable Spanning Tree.◦ NIC Frame Forwarding may be statically controlled, not learned.◦ NIC Frame Forwarding must allow Dom D to be “catchall”.

Page 42: XS Boston 2008 Networking Direct Assignment

Spanning Tree

5/14/2008

Page 43: XS Boston 2008 Networking Direct Assignment

MF-NIC treats each external port as uplink for a distinct bridge.Uplink is alwaysthe Root Port.Guest VNICs are alwaysDownstream Ports.There is never a Blocked Port.

5/14/2008

Page 44: XS Boston 2008 Networking Direct Assignment

If DomD or DomU forwards frames between “external” ports then there are problems•If Spanning Tree is not used then loops can result.•If Spanning Tree is used then one MF-NIC port may be deactivated.

5/14/2008

External bridge thinks this is 2nd path toSoft-Bridge, and therefore blocks it.

But MF-NIC Bridge does not know this.