KOTO実験における中性子背景事象 削減のためのMPPC読出し用回路の 開発 Yamanaka Taku Laboratory Yuta Sato 1

Upload: others

Post on 22-Jun-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28  · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm

KOTO実験における中性子背景事象削減のためのMPPC読出し用回路の

開発

Yamanaka Taku Laboratory Yuta Sato

1

Page 2: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28  · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm

• KOTO experiment

2

KOTO detector

KL

CsI crystals are placed in vacuum

Page 3: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28  · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm

• Background

3

Halo neutrons make 2γ-like events

BG

Page 4: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28  · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm

• Both-end readout of the CsI calorimeter

4

The depth of the shower made by neutrons and photons are different

Page 5: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28  · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm

• Both-end readout of the CsI calorimeter

5

The depth of the shower made by neutrons and photons are different

↓Calculate the position of the interaction by

measuring the timing difference

Page 6: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28  · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm

• Purpose

6

• Develop the circuit for the MPPC-side of the both-end readout

• To develop

• Connection between MPPCs ← Today's main topic

• Amplifier circuit

MPPCAmplifierADC CsI PMT

VacuumLow-power amplifier required

Page 7: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28  · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm

• Whole schematic of the install

7

4096 MPPCs in total

# of CsI Calorimeters:2240(Small) + 476(Large)

5 cm

5 cm2.5 cm

2.5 cm

Amplifier boards around CsI crystals

+HV ReadoutAmplifier

(Sum Amp.)

256 ch

2 m

Sensor size:6 mm × 6 mm

HPKS13360-6050CS

4 MPPCs

4 MPPCs

4 MPPCs

4 MPPCsSmall # of readout channels

4096 MPPCs → 256 readout channel

Page 8: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28  · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm

• Connection methods for MPPCs

8

Series connection

Beam hole

High radiation dose

Stacked CsI crystals

Distance from the beam axis [cm]

Neu

tron

flue

nce

Simulated by H. Nanjo

+HV

Readout

Page 9: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28  · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm

• Connection methods for MPPCs

9Vi' ≠ Vi

Page 10: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28  · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm

• Connection methods for MPPCs

10

+V

OUT DC component AC component

Hybrid connection

+V

OUTResistance and capacitance shorten the time constant

Parallel connection

MEG Ⅱ usesthis method

Page 11: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28  · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm

11

+HV Amplifier circuit(1 ch)

RJ45

OUT-

OUT+

• Readout circuit

Power consumption:55 mW / ch→ 14 W in total (256 ch)

Low power

4 MPPCs

4 MPPCs

4 MPPCs

4 MPPCs

Page 12: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28  · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm

• Waveforms (all MPPCs are viewing photons from LED)

12

Red: HybridGreen: ParallelBlack: Series

Time [μs]

Voltage [V]

Time constant: Series ~ Hybrid < Parallel Pulse height: Series ~ Hybrid > Parallel

Page 13: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28  · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm

• Cosmic ray test at J-PARC

13

Setup

• Compare the timing resolution between parallel and hybrid connection

Page 14: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28  · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm

• Cosmic ray test at J-PARC

14

Trigger position

Timing difference

T(MPPC) - T(PMT)

T

0.5 × Peak

Timing difference [ns]

#Waveform (MPPC)

Example ExampleTiming resolution:σ of the distribution

Page 15: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28  · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm

• Cosmic ray test at J-PARC

15

Red:ParallelGreen:Hybrid

Trigger position

Timing resolution [ns]

<Timing resolution>Parallel:(1.65 ± 0.03) nsHybrid:(1.45 ± 0.03) ns

Trigger position

Timing resolution

PMT sideMPPC side

<1.7 ns required

Page 16: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28  · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm

• Summary

16

• Prospects

• Evaluating the performance of two connection methods for 4-MPPCs

• Developed the amplifier board to readout signals from MPPCs

• Timing resolution of the readout system satisfies the requirement

• Understand and solve the problems found during the beamtest

Page 17: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28  · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm

Backup

17

Page 18: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28  · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm

• KOTO Experiment

18

Linac Rapid Cycle Synch. Main Ring

Linac RCS MRHadron Beam Facility400 MeV 3 GeV 30 GeV

J-PARC

Page 19: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28  · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm

19

Page 20: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28  · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm

Figures

20

Page 21: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28  · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm

21

MPPC CsI5 cm × 5 cm × 50 cm PMT

Plastic scintillators

Plastic scintillators

Cosmic ray654321

ADC