كب لاهأ - eugcc-cleanergy.net · the iec 61400 standard issued first in 2001 by the...
TRANSCRIPT
![Page 1: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/1.jpg)
11
أهال بك
صباح الخيرKalimera
kalosorisate
![Page 2: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/2.jpg)
22
White : peace and prosperity, Red: recalls battles against foreign invaders
Green: symbolizes the Jebel Akhdar, and fertility
![Page 3: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/3.jpg)
3
• Wind turbine(wind generator, wind energy converter) technology today and
future trends onshore & offshore, turbine certification,
• Wind resource evaluation (instruments-measurements-modeling),
meteorological parameters,
•Atmospheric boundary layer, wind speed profiles, analysis of
measurements, wind atlases onshore & offshore,
• Selection methodology of most suitable locations, site surveys,
• Environmental constrains of wind farms (wind parks or wind clusters),
• Energy yield (measurements-modeling-state of the art tools). Wake losses,
CFD codes,
•Social acceptability, aesthetics, noise calculations, good examples from
large wind farms in the world,
CASE STUDY
•A full example of technical and economic evaluation of a big wind
farm.
Hands on Exercises
•Design wind farms in areas of complex terrain
Wind Energy curriculum
![Page 4: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/4.jpg)
44
Welcome to the world of
wind energy
The Technology
Dr. D. V. KanellopoulosOPWP Renewable Energy
Training Program11-14 December 2016
Muscat, Oman
![Page 5: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/5.jpg)
55
Wind Systems- a short history
Wt development from the 1st century till today
1 AD
9 AD
12 AD
13 AD
19 AD
1922
1927
1931
1941
![Page 6: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/6.jpg)
66
Persian vertical axis
wind mill
![Page 7: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/7.jpg)
77
Wind Systems- Vertical axis wts
Rotor height, 100m
base height, 10 m
Rotor diameter,
64m
Cap-Chat, Quebec, 4 MW
Skyros Greece, 140 kW
![Page 8: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/8.jpg)
Wind Systems- Vertical axis wts
Rotor height
![Page 9: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/9.jpg)
![Page 10: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/10.jpg)
Ancient horizontal axis wind mills
![Page 11: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/11.jpg)
1111
Wind Systems- Dimensions
![Page 12: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/12.jpg)
![Page 13: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/13.jpg)
![Page 14: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/14.jpg)
![Page 15: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/15.jpg)
1515
Pitch control and stall control wts
![Page 16: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/16.jpg)
1616
Wind Systems- getting taller!
2014
![Page 17: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/17.jpg)
1717
Wind Systems- Today’s giants
Vestas V164, 8 MW Enercon E126, 7.5 MW
Repower 6M, 126m, 6.2MW Areva M5000, 113m, 5 MW
![Page 18: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/18.jpg)
1818
Wind Systems- power curve
Variable pitch wt
Normally give for air density, ρ=1.23 kg/m3
![Page 19: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/19.jpg)
1919
Wind Systems- power curve
Variable pitch machines
![Page 20: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/20.jpg)
2020
Wind Systems- power curveStall controlled
Rated output speed
Cut out speed
Cut in speed
Rated output power
![Page 21: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/21.jpg)
2121
DTU Wind Energy test station for large wind turbines at Høvsøre, situated on the West coast of Jutland, Denmark
Company Wt MW D(m) Hub
(m)
Tip
Height
(m)
Vestas V90-
2,0MW
2,0 90 84 129
Siemens SWT
4,0/130
4,0 130 95 160
Nordex N100-3,3 3,3 100 75 125
Siemens SWT 3,0-
113
3,0 113 99,5 156
![Page 22: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/22.jpg)
2222
Blade testing
![Page 23: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/23.jpg)
2323
Dynamometer at the 5-MW Dynamometer Test Facility
at NREL's National Wind Technology Center (NWTC).
![Page 24: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/24.jpg)
2424
Measured power curves
Average output
![Page 25: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/25.jpg)
2525
Measured power curves, atmospheric dependence
P/Pn
![Page 26: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/26.jpg)
2626
Measured power curves
![Page 27: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/27.jpg)
2727
Wind turbine certificationThe International IEC 61400-22 Standard, (IEC WT01)The IEC 61400 standard issued first in 2001 by the International ElectrotechnicalCommission (IEC) is a set of design requirements and considerations aiming to ensure the engineering integrity of wind turbines. Its purpose is to provide an appropriate level of protection against damage from all hazards during the planned lifetime.The IEC 61400 series is concerned with all subsystems of wind turbines such as control and protection mechanisms, internal electrical systems, mechanical systems and support structures covering the following topics:
•Design requirements•Design requirements for small wind turbines•Acoustic noise measurement techniques•Wind turbine power performance testing•Measurement of mechanical loads•Declaration of apparent sound power level and tonality values•Measurement and assessment of power quality characteristics of grid connected wind turbines•Full-scale structural testing of rotor blades•Lightning protection
The IEC 61400 standard applies to wind turbines of all sizes. For small wind turbines IEC 61400-2 may be applied. The standard is used together with other appropriate IEC and ISO standards.
![Page 28: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/28.jpg)
2828
Wind turbine certification
Wind Turbine Certification According to National Standards and Guidelines
In some countries, in addition to the international standard IEC 61400, special national guidelines and standards need to be considered for wind turbine certification. Danish, Dutch.
Type Certification According to DIBt
In Germany there is an official type certification of towers and foundations according to the Center of Competence in Civil Engineering (Deutsches Institut für Bautechnik, DIBt). This certification is only to be carried out by a Notified Body, to ensure accordance with national regulations.
![Page 29: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/29.jpg)
2929
Wind turbine certification
1: Evaluation Report
2: Conformity or Compliance Statement
3: Type Certificate
1 32
![Page 30: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/30.jpg)
3030
Date
issued
Date
valid
Wind turbine certification list
![Page 31: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/31.jpg)
3131
Wind turbine certification , www.measnet.com
Measuring Network of Wind Energy
Institutes
The goal: To work out rules and requirements which will guarantee that high quality measurements are carried out by them. The necessary creation of the network rules and the establishment of commonly agreed measurement methods were subsidised by the European Commission in two jointly performed projects. For the first time institutes being in commercial competition agreed to work together for the benefit of their clients with the objective to perform measurements of equal quality which are sufficient for the mutual comparison and acceptance that is necessary for the industry in an open World wide market.
EN 45001, IEC, IEA
![Page 32: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/32.jpg)
3232
Wind turbine certification
DOCUMENTSThe following documents are available :MEASUREMENT PROCEDURES:• Cup Anemometer Calibration Procedure – Version 2, October 2009 (PDF format 98 kbytes)• Power Performance Measurement Procedure – Version 5 , December 2009 (PDF format 977 kbytes)• Acoustic Noise Measurement Procedure (PDF format 29 kbytes)• Power Quality Measurement Procedure (PDF format 1300 kbytes)• Evaluation of Site specific Wind conditions (PDF format 440 kbytes)
BECOMING A MEMBER OF MEASNET :• Applicant Assessment Procedure -version 2 / september 2008 (PDF format 90 kbytes)
MEASNET STATEMENTS:• Calculation of specific site AEP september 2014 (PDF format 295 kbytes)• Shortcoming of AEP calculation as defined in IEC 61400-12-1 september 2014 (PDF format 172 kbytes)• New statement about anemometer calibration october 2012 (PDF format 100 kbytes)• Statement about anemometer calibration September 2009 (PDF format 58 kbytes)
![Page 33: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/33.jpg)
3333
Wind turbine certification
Air
flow
![Page 34: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/34.jpg)
3434
Without proper certification
and testing disaster struck!
![Page 35: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/35.jpg)
3535
https://www.youtube.com/watch?v=581Nw7-
FcoY&list=UUJHNBjI4tvfwYH2MTWJirlg&index=3&feature=plcp
Wind turbine certification
![Page 36: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/36.jpg)
3636
Wind turbine
![Page 37: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/37.jpg)
3737
A horizontal axis wind turbine
![Page 38: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/38.jpg)
3838
a HAWT with 2 shafts
![Page 39: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/39.jpg)
3939
WTS with an without a gear box
![Page 40: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/40.jpg)
4040
Direct Drive wt
![Page 41: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/41.jpg)
4141
![Page 42: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/42.jpg)
4242
AdvantagesIncreased efficiency: The power is not wasted in frictionReduced noise: Being a simpler device, a direct-drive mechanism has fewer parts which could vibrate, and the overall noise emission of the system is usually lower.Longer lifetime: Having fewer moving parts also means having fewer parts prone to failure. Failures in other systems are usually produced by aging of the component, or stress.High torque at low rpm.
Faster and precise positioning. High torque and low inertia allows faster positioning times on permanent magnet synchronous servo drives. Feedback sensor directly on rotary part allows precise angular position sensing.Drive stiffness. Mechanical backlash, hysteresis and elasticity is removed avoiding use of gearbox or ball screw mechanisms.
DisadvantagesThe main disadvantage of the system is that it needs a special motor. Usually motors are built to achieve maximum torque at high rotational speeds, usually 1500 or 3000 rpm.
The slow motor also needs to be physically larger than its faster counterpart.
Also, direct-drive mechanisms need a more precise control mechanism. High speed motors with speed reduction have relatively high inertia, which helps smooth the output motion. Most motors exhibit positional torque ripple known as cogging torque. In high speed motors, this effect is usually negligible, as the frequency at which it occurs is too high to significantly affect system performance; direct drive units will suffer more from this phenomenon, unless additional inertia is added or the system uses feedback to actively counter the effect.
Direct drive wt (NO gear box)
![Page 43: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/43.jpg)
Wind Turbine Generator (WTG) Classes (IEC 61400-1)
Wind turbines are designed for specific conditions. During the construction and design phase assumptions are made about the wind climate that the wind turbines will be exposed to. Turbine wind class is just one of the factors needing consideration during the complex process of planning a wind power plant. Wind classes determine which turbine is suitable for the normal wind conditions of a particular site.
Turbine classes are determined by three parameters:
• the average wind speed, Vave, or U(ave)
• extreme 50-year gust, Vg(50y)• and turbulence, I or TI (Turbulence Intensity)
Turbulence intensity quantifies how much the wind varies typically within 10 minutes. Because the fatigue loads of a number of major components in a wind turbine are mainly caused by turbulence, the knowledge of how turbulent a site is of crucial importance.
Normally the wind speed increases with increasing height. In flat terrain the wind speed increases logarithmically with height. In complex terrain the wind profile is not a simple increase and additionally a separation of the flow might occur, leading to heavily increased turbulence.
![Page 44: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/44.jpg)
Wind Turbine Generator (WTG) Classes (IEC 61400-1)
Iref is often given at U=15 m/s
![Page 45: كب لاهأ - eugcc-cleanergy.net · The IEC 61400 standard issued first in 2001 by the International Electrotechnical Commission (IEC) is a set of design requirements and considerations](https://reader030.vdocuments.net/reader030/viewer/2022041207/5d5fe3ed88c993c6098bd4d5/html5/thumbnails/45.jpg)
Wind Turbine Generator (WTG) Classes (IEC 61400-1)
H(hub)
Vmax( 10 min ave.)< or = to Vref
H(equator)