earthwell · fuxion: 66668789 strip in pipe pipe in pipe cu gi gi gi ear th well a d v a n c e d e...

4
EXPRESSIONS for the new generation EARTH WELL ADVANCED EARTHING & LIGHTNING PROTECTION SYSTEM

Upload: ngominh

Post on 19-Sep-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EARTHWELL · Fuxion: 66668789 Strip in Pipe Pipe in Pipe CU GI GI GI EAR TH WELL A D V A N C E D E A R T H I N G & L I G H T N I N G P R O T E C T I O N S Y S T E M EAR TH WELL A

EXPRESSIONSfor the new generation

EARTH WELLADVANCED EARTHING & LIGHTNING PROTECTION SYSTEM

Page 2: EARTHWELL · Fuxion: 66668789 Strip in Pipe Pipe in Pipe CU GI GI GI EAR TH WELL A D V A N C E D E A R T H I N G & L I G H T N I N G P R O T E C T I O N S Y S T E M EAR TH WELL A

Advantages

Highly conductive earth-pit backfill

Reduces soil resistivity by upto 90%

Non-corrosive

Independent of ambient moisture content, hence works in all weather conditions

Compatible with all types of earthing electrodes, be it pipes, plates or rods of any metal

Can also be used in trenches made for horizontal type earthing systems

Advanced Earthing Compound

EARTH WELLADVANCED EARTHING & LIGHTNING PROTECTION SYSTEM

ADVANCED EARTHING COMPOUND

Net Wt. 25 Kgs.

ADVANCED EARTHING COMPOUND

EARTH WELLADVANCED EARTHING & LIGHTNING PROTECTION SYSTEM

Net Wt. 25 Kgs.

Increases the total surface area of the earthing electrode ensuring quick dissipation of fault currents

Maintains constant volume regardless of moisture content

Earthwell Earthing Compound doesn't shrink or expand. It maintains constant contact with electrode and surrounding soil

Long shelf life; can be stored for very long periods without deterioration

Environmental friendly; does not pollute or contaminate the water table

GI Plate Earthing

Plate Earthing

Copper Plate Earthing

Features

The earth connection can be provided with the

help of a copper/G.I. plate. When G.I. plate is used

it should not be of less than 60 cm x 60 cm x 6.35

mm.

The plate is kept with its face vertical at a depth of

3 m and is so arranged that it is embedded in an

alternate layer of coke and salt for a minimum

thickness of about 15 cm in case earthing is done

by copper plate and in coke layer of 15 cm if it is

done with GL Plate- The earth wire is securely

bolted t0 the earth plate with the help of bolt nut

and washer.

Pipe Earthing

(I) The earthing electrode should be situated at a place at least

1½ metre away from (i.e. outside) the building whose

installation system is being earthen.

(ii) The earth wire should be of same material as that of earth

electrode.

(iii) The minimum sectional area of the earth lead wire should

never be less than 0.02 sq. inch (No. 8 S.W.G.) and not

more than 0.1 sq. inch (i.e. 7.036 S.W.G.).

(iv) The size of earth conductor as a general rule should not be

less than half of the section of live line conductor.

(V) The size of the continuous earth wires used with cables

should not be either less than 0.0045 sq. in (14 S.W.G.) or

half of the installation conductor

Pipe Earthing Features:

Low electrical resistance and high corrosion resistance

Connectivity up to chamber or earth terminals

Reliable, durable and easy to handle

Highly secure and well tested by using latest technology

Optimum quality performance and available in different sizes

GI Pipe Earthing ElectrodeModel Length Pipe Dia

(mm) (mm)

EWIT-140GIP 1000 40

EWIT-240GIP 2000 40

EWIT-250GIP 2000 50

EWIT-340GIP 3000 40

EWIT-350GIP 3000 50

Our company manufactures and supplies a comprehensive range of Cast Iron Pipe

Earthing to our clients. This hi tech equipment is widely used in IT software

companies, telecommunication towers, oil refineries, pumping stations, lightning

protection systems, power generators, etc. These devices, crafted using high

quality raw materials, are tested on stiff quality grounds for ensuring better results.

Features

Anti corrosive

Convenient to install

Highly conductive

Safe and reliable

CI Pipe Earthing

Specifications

Size: 75 mm TO 150 mm

Thickness: 3.5 mm TO 13 mm

Length: 3 mtr.

Material: Grey Cast Iron

Carbon: 3.5% TO 3.8%

Manganese: 3.5% TO 5%

Phosphors: 0.12% to 0.2%

GI Pipe Earthing CI Pipe Earthing

Available in 25 & 10 Kgs Bag

Page 3: EARTHWELL · Fuxion: 66668789 Strip in Pipe Pipe in Pipe CU GI GI GI EAR TH WELL A D V A N C E D E A R T H I N G & L I G H T N I N G P R O T E C T I O N S Y S T E M EAR TH WELL A

MODEL Length Rod Dia Rod Dia

(mm) (mm) (inches)

EWIT-CB614 2000 14.2 5/8”

EWIT-CB1014 3000 14.2 5/8”

EWIT-CB617 2000 17.2 3/4”

EWIT-CB1017 3000 17.2 3/4”

B

A

C

Description Material ABC Dimensions mm Weight Each

Concrete Inspection Concrete with Stainless 320 x 320 x 192 30 Kg.

Pit Steel Lifting Hook

Bentonite Moisture Retaining Compound

Lightning Protection System (Franklin Rod)

Copper Earthing RodsTripoleCopper Bonded

Earthing Rods

HIGH TENSIL LOW CARBON STEEL

MOLECULARLY BONDED 99.9% PURE ELECTROLYTIC COPPER

Lightning Arrester (ESE Terminal)Advantages

The area to be protected is a dangerous

area, lightning conductor can be installed

outside

Possible to protect several buildings with

the same lightning conductor Economic

Possible to protect a structure and its

surrounding environment at the same time

Protection of open zones

Can be integrated seamlessly and discreetly

into the building struck

These Principle

Experiments are described which are designed to test two devices based on

the ‘early streamer emission’ (ESE) principle, for lightning protection, against

the traditional Franklin rod. In all three cases, the device was subjected to a

steady negative electric field from a sphere, simulating the field beneath a

thundercloud, prior to application of a superimposed negative impulse field,

simulating the field due to the downward leader. The first device consisted of

a vertical rod to which a subsidiary 1/50 s positive impulse voltage, variable

up to 40 kV peak, could be applied with varying delays from the start of the

negative impulse field. Energising of the rod was thus independent of the

applied negative field. The second device was a commercial product,

energising of which was controlled by its own power supply. Sparkover

voltages in the sphere/device gaps and times to breakdown were measured.

It is shown that the ESE devices showed a small advantage, in time to

breakdown, over the Franklin rod

Multiple Point Air Terminal

Model Length Rod Dia Sphere Size Material

(MM)

EWIT – FR 60 1200 25.4 60 COPPER

EWIT – FR 80 1200 25.4 80 COPPER

EWIT – FR 100 1200 25.4 100 COPPER

Range of Radius Protection50 mtrs, 65 mtrs, 90 mtrs

and 108 mtrs.

ESCOLTRIX

Page 4: EARTHWELL · Fuxion: 66668789 Strip in Pipe Pipe in Pipe CU GI GI GI EAR TH WELL A D V A N C E D E A R T H I N G & L I G H T N I N G P R O T E C T I O N S Y S T E M EAR TH WELL A

Advanced Earthing Electrodes

Plot No. 101, 1st Floor, KPHB Colony, Road No.4, Kukatpally, Hyderabad - 500 072, Telangana, India.Tel : 040-40274011 Mob: 92460 67549, 80746 67946

Email: [email protected] Website: www.earthwel.com

EARTH WELLADVANCED EARTHING & LIGHTNING PROTECTION SYSTEM

Fu

xion: 66668789

Strip in Pipe Pipe in Pipe

CUGI GI

GI

EARTH

WELL

AD

VAN

CED

EA

RTH

ING

& L

IGH

TNIN

G P

RO

TEC

TIO

N S

YSTE

M

EARTH

WELL

AD

VAN

CED

EA

RTH

ING

& L

IGH

TNIN

G P

RO

TEC

TIO

N S

YSTE

M

EARTH

WELL

AD

VAN

CED

EA

RTH

ING

& L

IGH

TNIN

G P

RO

TEC

TIO

N S

YSTE

M

EARTH

WELL

AD

VAN

CED

EA

RTH

ING

& L

IGH

TNIN

G P

RO

TEC

TIO

N S

YSTE

M

EARTH

WELL

AD

VAN

CED

EA

RTH

ING

& L

IGH

TNIN

G P

RO

TEC

TIO

N S

YSTE

M

EARTH

WELL

AD

VAN

CED

EA

RTH

ING

& L

IGH

TNIN

G P

RO

TEC

TIO

N S

YSTE

M

EARTH

WELL

AD

VAN

CED

EA

RTH

ING

& L

IGH

TNIN

G P

RO

TEC

TIO

N S

YSTE

M

EARTH

WELL

AD

VAN

CED

EA

RTH

ING

& L

IGH

TNIN

G P

RO

TEC

TIO

N S

YSTE

M

GI Pipe GI Strip ELectrode

Model Length Pipe Dia Strip Size (mm) (mm) (mm)

EWIT-150G 1000 50 40 x 6 x 1100

EWIT-180G 1000 80 50 x 6 x 1100

EWIT-250G 2000 50 40 x 6 x 2100

EWIT-280G 2000 80 50 x 6 x 2100

EWIT-350G 3000 50 40 x 6 x 3100

EWIT-380G 3000 80 50 x 6 x 3100

GI Pipe in Pipe Electrodes

Model Length Pipe Dia Inner pipe Strip Size (mm) (mm) (mm) (mm)

EWIT-250G 2000 50 40 30 x 6

EWIT-280G 2000 80 50 40 x 6

EWIT-350G 3000 50 40 30 x 6

EWIT-380G 3000 80 50 40 x 6

Copper Strip GI/CU Electrodes

Model Length Pipe Dia Pipe Type Strip Size (mm) (mm) (mm)

EWIT-150GC 1000 50 GI 40 x 6 x 1100

EWIT-250GC/CC 2000 50 GI/CU 40 x 6 x 2100

EWIT-280GC/CC 2000 80 GI/CU 50 x 6 x 2100

EWIT-350GC/CC 3000 50 GI/CU 40 x 6 x 3100

EWIT-380GC/CC 3000 80 GI/CU 50 x 6 x 3100

Copper Bonded ELectrode

Model Length Pipe Dia Strip Size (mm) (mm) (mm)

EWIT-150CB 1000 50 40 x 6 x 1100

EWIT-180CB 1000 80 50 x 6 x 1100

EWIT-250CB 2000 50 40 x 6 x 2100

EWIT-280CB 2000 80 50 x 6 x 2100

EWIT-350CB 3000 50 40 x 6 x 3100

EWIT-380CB 3000 80 50 x 6 x 3100

'EARTHWELL Advanced Earthing Electrode is a combination of specially developed

“Earthing Electrode” and “BACK FILL COMPOUND”.

A revolutionary corrosion free grounding system provides high-tech and noise free

earthing for electrical, electronics, communication, data (digital & analog) and

lightning systems

Earthing System

A Maintenance free Earthing System

· Long and reliable average life of 15 Plus years

· Maintenance Free

· High Cost savings on maintenance and replacement over 15 Plus years

· Very Smooth dissipation of fault, lightning and short circuit currents

· Low electrical resistance to earth

· High Resistance to corrosion

· Repeated current carrying capacity and continuity Control

· Ideal earthing system for electric/sensitive electronic appliances, equipment and

machinery

· Safety of life and property from earth related electrical hazards