30 Subject to change Control- and safety isolating- resp. isolating transformer STEU General Data Rated input voltage 230 and 400 Vac Rated output voltage 24 - 230 Vac Rated power 63 - 2500 VA Insulation class B Maximum ambient temperature 40 °C Efficiency up to 94 % Degree of protection IP 00 Advantages Dual input voltage 230 and 400 Vac Very good switch-on behaviour thanks to reduced starting currents High performance for the volume thanks to compact design Primary side ±15 V tappings for voltage adjustment Very good corrosion protection and low noise thanks to BLOCKIMPEX vacuum impregnation Quick to cable up thanks to the use of spring-clamp terminals Contact protected screw connection terminals complying with UVV BGV A3 Simple mounting thanks to robust metal footplate with oval slots Up to 250 VA with combination footplate for bolted and rail mounting Applications As a control transformer for the electrical isolation of the input and output sides. The construction of the transformer to supply control systems according to VDE 0113 is designed. As an isolating transformer for the safe electrical isolation of the input and output sides. The transformer may be used to set up protective separation as a protective measure in accordance with VDE 0100. As a safety transformer for the safe electrical isolation of the input and output sides. The transformer is suitable for creating SELV and PELV circuits because of the limit on the output voltage. Sample application Standards 2 | " Z Approvals W J Z Control transformer to: VDE 0570 Teil 2-2, DIN EN 61558-2-2, EN 61558-2-2, IEC 61558-2-2, UL 5085-1/-2, CSA 22.2 No.66 UL 5085-1/-2, CSA 22.2 No.66 Safety isolating transformer to: VDE 0570 Teil 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL 5085-1/-2, CSA 22.2 No.66 Isolating transformer to: VDE 0570 Part2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4, UL 5085-1/-2, CSA 22.2 No.66 Transformers Control transformers 1 BLOCK Website

Upload: others

Post on 22-Aug-2021

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1 Control transformers Transformers · 2019. 10. 12. · to: VDE 0570 Part2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4, UL 5085-1/-2, CSA 22.2 No.66 UL 5085-1/-2, CSA 22.2 No.66

30 Subject to change

Control- and safety isolating- resp isolatingtransformerSTEU

General Data

Rated input voltage 230 and 400 Vac

Rated output voltage 24 - 230 Vac

Rated power 63 - 2500 VA

Insulation class B

Maximum ambient temperature 40 degC

Efficiency up to 94

Degree of protection IP 00

Advantages

Dual input voltage 230 and 400 Vac

Very good switch-on behaviour thanks to reduced starting currents

High performance for the volume thanks to compact design

Primary side plusmn15 V tappings for voltage adjustment

Very good corrosion protection and low noise thanks to BLOCKIMPEXvacuum impregnation

Quick to cable up thanks to the use of spring-clamp terminals

Contact protected screw connection terminals complying with UVV BGV A3

Simple mounting thanks to robust metal footplate with oval slots

Up to 250 VA with combination footplate for bolted and rail mounting

Applications

As a control transformer for the electrical isolation of the input and outputsides The construction of the transformer to supply control systems accordingto VDE 0113 is designed

As an isolating transformer for the safe electrical isolation of the input andoutput sides The transformer may be used to set up protective separation as aprotective measure in accordance with VDE 0100

As a safety transformer for the safe electrical isolation of the input and outputsides The transformer is suitable for creating SELV and PELV circuits becauseof the limit on the output voltage

Sample application

Standards 2 | Z

Approvals W J Z

Control transformerto VDE 0570 Teil 2-2 DIN EN 61558-2-2 EN 61558-2-2 IEC 61558-2-2UL 5085-1-2 CSA 222 No66 Safety isolating transformerto VDE 0570 Teil 2-6 DIN EN 61558-2-6 EN 61558-2-6 IEC 61558-2-6 UL5085-1-2 CSA 222 No66 Isolating transformerto VDE 0570 Part2-4 DIN EN 61558-2-4 EN 61558-2-4 IEC 61558-2-4 UL5085-1-2 CSA 222 No66

UL 5085-1-2 CSA 222 No66

Control- and safety isolating- resp isolatingtransformerSTEU

General Data

Rated input voltage 230 and 400 Vac

Rated output voltage 24 - 230 Vac

Rated power 63 - 2500 VA

Insulation class B

Maximum ambient temperature 40 degC

Efficiency up to 94

Degree of protection IP 00

Advantages

Dual input voltage 230 and 400 Vac

Very good switch-on behaviour thanks to reduced starting currents

High performance for the volume thanks to compact design

Primary side plusmn15 V tappings for voltage adjustment

Very good corrosion protection and low noise thanks to BLOCKIMPEXvacuum impregnation

Quick to cable up thanks to the use of spring-clamp terminals

Contact protected screw connection terminals complying with UVV BGV A3

Simple mounting thanks to robust metal footplate with oval slots

Up to 250 VA with combination footplate for bolted and rail mounting

Applications

As a control transformer for the electrical isolation of the input and outputsides The construction of the transformer to supply control systems accordingto VDE 0113 is designed

As an isolating transformer for the safe electrical isolation of the input andoutput sides The transformer may be used to set up protective separation as aprotective measure in accordance with VDE 0100

As a safety transformer for the safe electrical isolation of the input and outputsides The transformer is suitable for creating SELV and PELV circuits becauseof the limit on the output voltage

Sample application

Standards 2 | Z

Approvals W J Z

Control transformerto VDE 0570 Teil 2-2 DIN EN 61558-2-2 EN 61558-2-2 IEC 61558-2-2UL 5085-1-2 CSA 222 No66 Safety isolating transformerto VDE 0570 Teil 2-6 DIN EN 61558-2-6 EN 61558-2-6 IEC 61558-2-6 UL5085-1-2 CSA 222 No66 Isolating transformerto VDE 0570 Part2-4 DIN EN 61558-2-4 EN 61558-2-4 IEC 61558-2-4 UL5085-1-2 CSA 222 No66

UL 5085-1-2 CSA 222 No66

Control- and safety isolating- resp isolatingtransformerSTEU

General Data

Rated input voltage 230 and 400 Vac

Rated output voltage 24 - 230 Vac

Rated power 63 - 2500 VA

Insulation class B

Maximum ambient temperature 40 degC

Efficiency up to 94

Degree of protection IP 00

Advantages

Dual input voltage 230 and 400 Vac

Very good switch-on behaviour thanks to reduced starting currents

High performance for the volume thanks to compact design

Primary side plusmn15 V tappings for voltage adjustment

Very good corrosion protection and low noise thanks to BLOCKIMPEXvacuum impregnation

Quick to cable up thanks to the use of spring-clamp terminals

Contact protected screw connection terminals complying with UVV BGV A3

Simple mounting thanks to robust metal footplate with oval slots

Up to 250 VA with combination footplate for bolted and rail mounting

Applications

As a control transformer for the electrical isolation of the input and outputsides The construction of the transformer to supply control systems accordingto VDE 0113 is designed

As an isolating transformer for the safe electrical isolation of the input andoutput sides The transformer may be used to set up protective separation as aprotective measure in accordance with VDE 0100

As a safety transformer for the safe electrical isolation of the input and outputsides The transformer is suitable for creating SELV and PELV circuits becauseof the limit on the output voltage

Sample application

Standards 2 | Z

Approvals W J Z

Control transformerto VDE 0570 Teil 2-2 DIN EN 61558-2-2 EN 61558-2-2 IEC 61558-2-2UL 5085-1-2 CSA 222 No66 Safety isolating transformerto VDE 0570 Teil 2-6 DIN EN 61558-2-6 EN 61558-2-6 IEC 61558-2-6 UL5085-1-2 CSA 222 No66 Isolating transformerto VDE 0570 Part2-4 DIN EN 61558-2-4 EN 61558-2-4 IEC 61558-2-4 UL5085-1-2 CSA 222 No66

UL 5085-1-2 CSA 222 No66

Control- and safety isolating- resp isolatingtransformerSTEU

General Data

Rated input voltage 230 and 400 Vac

Rated output voltage 24 - 230 Vac

Rated power 63 - 2500 VA

Insulation class B

Maximum ambient temperature 40 degC

Efficiency up to 94

Degree of protection IP 00

Advantages

Dual input voltage 230 and 400 Vac

Very good switch-on behaviour thanks to reduced starting currents

High performance for the volume thanks to compact design

Primary side plusmn15 V tappings for voltage adjustment

Very good corrosion protection and low noise thanks to BLOCKIMPEXvacuum impregnation

Quick to cable up thanks to the use of spring-clamp terminals

Contact protected screw connection terminals complying with UVV BGV A3

Simple mounting thanks to robust metal footplate with oval slots

Up to 250 VA with combination footplate for bolted and rail mounting

Applications

As a control transformer for the electrical isolation of the input and outputsides The construction of the transformer to supply control systems accordingto VDE 0113 is designed

As an isolating transformer for the safe electrical isolation of the input andoutput sides The transformer may be used to set up protective separation as aprotective measure in accordance with VDE 0100

As a safety transformer for the safe electrical isolation of the input and outputsides The transformer is suitable for creating SELV and PELV circuits becauseof the limit on the output voltage

Sample application

Standards 2 | Z

Approvals W J Z

Control transformerto VDE 0570 Teil 2-2 DIN EN 61558-2-2 EN 61558-2-2 IEC 61558-2-2UL 5085-1-2 CSA 222 No66 Safety isolating transformerto VDE 0570 Teil 2-6 DIN EN 61558-2-6 EN 61558-2-6 IEC 61558-2-6 UL5085-1-2 CSA 222 No66 Isolating transformerto VDE 0570 Part2-4 DIN EN 61558-2-4 EN 61558-2-4 IEC 61558-2-4 UL5085-1-2 CSA 222 No66

UL 5085-1-2 CSA 222 No66

Transformers Control transformers1

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 6348 STEU 6324 STEU 6323 STEU 10048 STEU 10024 STEU 10023

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x24 Vac 2x12 Vac 2x115 Vac 2x24 Vac 2x12 Vac 2x115 Vac

Rated power VDE (DB cos phi=1) 63 VA 63 VA 63 VA 100 VA 100 VA 100 VA

Rated power VDE (KB cos phi=05) 175 VA 175 VA 175 VA 310 VA 310 VA 175 VA

No-load voltage (app x factor) 110 110 110 107 107 107

Efficiency 86 86 86 86 86 86

StandardsClassification Control- and safety isolating

transformerControl- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 025 - 040 A 025 - 040 A 025 - 040 A 040 - 063 A 040 - 063 A 040 - 063 A

Setting value 230 plusmn15 Vac 035 A 035 A 035 A 050 A 050 A 050 A

Setting range 400 plusmn15 Vac 016 - 025 A 016 - 025 A 016 - 025 A 025 - 040 A 025 - 040 A 025 - 040 A

Setting value 400 plusmn15 Vac 020 A 020 A 020 A 029 A 029 A 029 A

Order numbersOrder Number STEU 6348 STEU 6324 STEU 6323 STEU 10048 STEU 10024 STEU 10023

+-

BLOCKWebsite

11

12

51

13

21

22

31

32

33

52

40

Subject to change 31

Control- and safety isolating- resp isolatingtransformerSTEU

General Data

Rated input voltage 230 and 400 Vac

Rated output voltage 24 - 230 Vac

Rated power 63 - 2500 VA

Insulation class B

Maximum ambient temperature 40 degC

Efficiency up to 94

Degree of protection IP 00

Advantages

Dual input voltage 230 and 400 Vac

Very good switch-on behaviour thanks to reduced starting currents

High performance for the volume thanks to compact design

Primary side plusmn15 V tappings for voltage adjustment

Very good corrosion protection and low noise thanks to BLOCKIMPEXvacuum impregnation

Quick to cable up thanks to the use of spring-clamp terminals

Contact protected screw connection terminals complying with UVV BGV A3

Simple mounting thanks to robust metal footplate with oval slots

Up to 250 VA with combination footplate for bolted and rail mounting

Applications

As a control transformer for the electrical isolation of the input and outputsides The construction of the transformer to supply control systems accordingto VDE 0113 is designed

As an isolating transformer for the safe electrical isolation of the input andoutput sides The transformer may be used to set up protective separation as aprotective measure in accordance with VDE 0100

As a safety transformer for the safe electrical isolation of the input and outputsides The transformer is suitable for creating SELV and PELV circuits becauseof the limit on the output voltage

Sample application

Standards 2 | Z

Approvals W J Z

Control transformerto VDE 0570 Teil 2-2 DIN EN 61558-2-2 EN 61558-2-2 IEC 61558-2-2UL 5085-1-2 CSA 222 No66 Safety isolating transformerto VDE 0570 Teil 2-6 DIN EN 61558-2-6 EN 61558-2-6 IEC 61558-2-6 UL5085-1-2 CSA 222 No66 Isolating transformerto VDE 0570 Part2-4 DIN EN 61558-2-4 EN 61558-2-4 IEC 61558-2-4 UL5085-1-2 CSA 222 No66

UL 5085-1-2 CSA 222 No66

Control- and safety isolating- resp isolatingtransformerSTEU

General Data

Rated input voltage 230 and 400 Vac

Rated output voltage 24 - 230 Vac

Rated power 63 - 2500 VA

Insulation class B

Maximum ambient temperature 40 degC

Efficiency up to 94

Degree of protection IP 00

Advantages

Dual input voltage 230 and 400 Vac

Very good switch-on behaviour thanks to reduced starting currents

High performance for the volume thanks to compact design

Primary side plusmn15 V tappings for voltage adjustment

Very good corrosion protection and low noise thanks to BLOCKIMPEXvacuum impregnation

Quick to cable up thanks to the use of spring-clamp terminals

Contact protected screw connection terminals complying with UVV BGV A3

Simple mounting thanks to robust metal footplate with oval slots

Up to 250 VA with combination footplate for bolted and rail mounting

Applications

As a control transformer for the electrical isolation of the input and outputsides The construction of the transformer to supply control systems accordingto VDE 0113 is designed

As an isolating transformer for the safe electrical isolation of the input andoutput sides The transformer may be used to set up protective separation as aprotective measure in accordance with VDE 0100

As a safety transformer for the safe electrical isolation of the input and outputsides The transformer is suitable for creating SELV and PELV circuits becauseof the limit on the output voltage

Sample application

Standards 2 | Z

Approvals W J Z

Control transformerto VDE 0570 Teil 2-2 DIN EN 61558-2-2 EN 61558-2-2 IEC 61558-2-2UL 5085-1-2 CSA 222 No66 Safety isolating transformerto VDE 0570 Teil 2-6 DIN EN 61558-2-6 EN 61558-2-6 IEC 61558-2-6 UL5085-1-2 CSA 222 No66 Isolating transformerto VDE 0570 Part2-4 DIN EN 61558-2-4 EN 61558-2-4 IEC 61558-2-4 UL5085-1-2 CSA 222 No66

UL 5085-1-2 CSA 222 No66

Control- and safety isolating- resp isolatingtransformerSTEU

General Data

Rated input voltage 230 and 400 Vac

Rated output voltage 24 - 230 Vac

Rated power 63 - 2500 VA

Insulation class B

Maximum ambient temperature 40 degC

Efficiency up to 94

Degree of protection IP 00

Advantages

Dual input voltage 230 and 400 Vac

Very good switch-on behaviour thanks to reduced starting currents

High performance for the volume thanks to compact design

Primary side plusmn15 V tappings for voltage adjustment

Very good corrosion protection and low noise thanks to BLOCKIMPEXvacuum impregnation

Quick to cable up thanks to the use of spring-clamp terminals

Contact protected screw connection terminals complying with UVV BGV A3

Simple mounting thanks to robust metal footplate with oval slots

Up to 250 VA with combination footplate for bolted and rail mounting

Applications

As a control transformer for the electrical isolation of the input and outputsides The construction of the transformer to supply control systems accordingto VDE 0113 is designed

As an isolating transformer for the safe electrical isolation of the input andoutput sides The transformer may be used to set up protective separation as aprotective measure in accordance with VDE 0100

As a safety transformer for the safe electrical isolation of the input and outputsides The transformer is suitable for creating SELV and PELV circuits becauseof the limit on the output voltage

Sample application

Standards 2 | Z

Approvals W J Z

Control transformerto VDE 0570 Teil 2-2 DIN EN 61558-2-2 EN 61558-2-2 IEC 61558-2-2UL 5085-1-2 CSA 222 No66 Safety isolating transformerto VDE 0570 Teil 2-6 DIN EN 61558-2-6 EN 61558-2-6 IEC 61558-2-6 UL5085-1-2 CSA 222 No66 Isolating transformerto VDE 0570 Part2-4 DIN EN 61558-2-4 EN 61558-2-4 IEC 61558-2-4 UL5085-1-2 CSA 222 No66

UL 5085-1-2 CSA 222 No66

Control- and safety isolating- resp isolatingtransformerSTEU

General Data

Rated input voltage 230 and 400 Vac

Rated output voltage 24 - 230 Vac

Rated power 63 - 2500 VA

Insulation class B

Maximum ambient temperature 40 degC

Efficiency up to 94

Degree of protection IP 00

Advantages

Dual input voltage 230 and 400 Vac

Very good switch-on behaviour thanks to reduced starting currents

High performance for the volume thanks to compact design

Primary side plusmn15 V tappings for voltage adjustment

Very good corrosion protection and low noise thanks to BLOCKIMPEXvacuum impregnation

Quick to cable up thanks to the use of spring-clamp terminals

Contact protected screw connection terminals complying with UVV BGV A3

Simple mounting thanks to robust metal footplate with oval slots

Up to 250 VA with combination footplate for bolted and rail mounting

Applications

As a control transformer for the electrical isolation of the input and outputsides The construction of the transformer to supply control systems accordingto VDE 0113 is designed

As an isolating transformer for the safe electrical isolation of the input andoutput sides The transformer may be used to set up protective separation as aprotective measure in accordance with VDE 0100

As a safety transformer for the safe electrical isolation of the input and outputsides The transformer is suitable for creating SELV and PELV circuits becauseof the limit on the output voltage

Sample application

Standards 2 | Z

Approvals W J Z

Control transformerto VDE 0570 Teil 2-2 DIN EN 61558-2-2 EN 61558-2-2 IEC 61558-2-2UL 5085-1-2 CSA 222 No66 Safety isolating transformerto VDE 0570 Teil 2-6 DIN EN 61558-2-6 EN 61558-2-6 IEC 61558-2-6 UL5085-1-2 CSA 222 No66 Isolating transformerto VDE 0570 Part2-4 DIN EN 61558-2-4 EN 61558-2-4 IEC 61558-2-4 UL5085-1-2 CSA 222 No66

UL 5085-1-2 CSA 222 No66

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 6348 STEU 6324 STEU 6323 STEU 10048 STEU 10024 STEU 10023

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x24 Vac 2x12 Vac 2x115 Vac 2x24 Vac 2x12 Vac 2x115 Vac

Rated power VDE (DB cos phi=1) 63 VA 63 VA 63 VA 100 VA 100 VA 100 VA

Rated power VDE (KB cos phi=05) 175 VA 175 VA 175 VA 310 VA 310 VA 175 VA

No-load voltage (app x factor) 110 110 110 107 107 107

Efficiency 86 86 86 86 86 86

StandardsClassification Control- and safety isolating

transformerControl- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 025 - 040 A 025 - 040 A 025 - 040 A 040 - 063 A 040 - 063 A 040 - 063 A

Setting value 230 plusmn15 Vac 035 A 035 A 035 A 050 A 050 A 050 A

Setting range 400 plusmn15 Vac 016 - 025 A 016 - 025 A 016 - 025 A 025 - 040 A 025 - 040 A 025 - 040 A

Setting value 400 plusmn15 Vac 020 A 020 A 020 A 029 A 029 A 029 A

Order numbersOrder Number STEU 6348 STEU 6324 STEU 6323 STEU 10048 STEU 10024 STEU 10023

+-Transformers Control transformers1

BLOCKWebsite

32 Subject to change

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 16048 STEU 16024 STEU 16023 STEU 25048 STEU 25024 STEU 25023

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x24 Vac 2x12 Vac 2x115 Vac 2x24 Vac 2x12 Vac 2x115 Vac

Rated power VDE (DB cos phi=1) 160 VA 160 VA 160 VA 250 VA 250 VA 250 VA

Rated power VDE (KB cos phi=05) 490 VA 490 VA 490 VA 850 VA 850 VA 850 VA

No-load voltage (app x factor) 110 110 110 107 107 107

Efficiency 86 86 86 88 88 88

StandardsClassification Control- and isolating

transformerControl- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 063 - 100 A 063 - 100 A 063 - 100 A 100 - 160 A 100 - 160 A 100 - 160 A

Setting value 230 plusmn15 Vac 080 A 080 A 080 A 120 A 120 A 120 A

Setting range 400 plusmn15 Vac 040 - 063 A 040 - 063 A 040 - 063 A 063 - 100 A 063 - 100 A 063 - 100 A

Setting value 400 plusmn15 Vac 046 A 046 A 046 A 070 A 070 A 070 A

Order numbersOrder Number STEU 16048 STEU 16024 STEU 16023 STEU 25048 STEU 25024 STEU 25023

+-Transformers Control transformers1

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 32048 STEU 32024 STEU 32023 STEU 40024 STEU 40023 STEU 50048

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x24 Vac 2x12 Vac 2x115 Vac 2x12 Vac 2x115 Vac 2x24 Vac

Rated power VDE (DB cos phi=1) 320 VA 320 VA 320 VA 400 VA 400 VA 500 VA

Rated power VDE (KB cos phi=05) 1120 VA 1120 VA 1120 VA 1440 VA 1440 VA 2000 VA

No-load voltage (app x factor) 107 107 107 104 104 104

Efficiency 90 90 90 90 90 92

StandardsClassification Control- and isolating

transformerControl- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 100 - 160 A 100 - 160 A 100 - 160 A 160 - 250 A 160 - 250 A 160 - 250 A

Setting value 230 plusmn15 Vac 150 A 150 A 150 A 190 A 190 A 240 A

Setting range 400 plusmn15 Vac 063 - 100 A 063 - 100 A 063 - 100 A 100 - 160 A 100 - 160 A 100 - 160 A

Setting value 400 plusmn15 Vac 088 A 088 A 088 A 110 A 110 A 140 A

Order numbersOrder Number STEU 32048 STEU 32024 STEU 32023 STEU 40024 STEU 40023 STEU 50048

+-

BLOCKWebsite

11

12

51

13

21

22

31

32

33

52

40

Subject to change 33

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 32048 STEU 32024 STEU 32023 STEU 40024 STEU 40023 STEU 50048

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x24 Vac 2x12 Vac 2x115 Vac 2x12 Vac 2x115 Vac 2x24 Vac

Rated power VDE (DB cos phi=1) 320 VA 320 VA 320 VA 400 VA 400 VA 500 VA

Rated power VDE (KB cos phi=05) 1120 VA 1120 VA 1120 VA 1440 VA 1440 VA 2000 VA

No-load voltage (app x factor) 107 107 107 104 104 104

Efficiency 90 90 90 90 90 92

StandardsClassification Control- and isolating

transformerControl- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 100 - 160 A 100 - 160 A 100 - 160 A 160 - 250 A 160 - 250 A 160 - 250 A

Setting value 230 plusmn15 Vac 150 A 150 A 150 A 190 A 190 A 240 A

Setting range 400 plusmn15 Vac 063 - 100 A 063 - 100 A 063 - 100 A 100 - 160 A 100 - 160 A 100 - 160 A

Setting value 400 plusmn15 Vac 088 A 088 A 088 A 110 A 110 A 140 A

Order numbersOrder Number STEU 32048 STEU 32024 STEU 32023 STEU 40024 STEU 40023 STEU 50048

+-Transformers Control transformers1

BLOCKWebsite

34 Subject to change

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 50024 STEU 50023 STEU 63024 STEU 63023 STEU 80048 STEU 80024

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x12 Vac 2x115 Vac 2x12 Vac 2x115 Vac 2x24 Vac 2x12 Vac

Rated power VDE (DB cos phi=1) 500 VA 500 VA 630 VA 630 VA 800 VA 800 VA

Rated power VDE (KB cos phi=05) 2000 VA 2000 VA 2350 VA 2350 VA 3400 VA 3400 VA

No-load voltage (app x factor) 104 104 104 104 103 103

Efficiency 92 92 92 92 94 94

StandardsClassification Control- and safety isolating

transformerControl- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

Control- and safety isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 160 - 250 A 160 - 250 A 250 - 400 A 250 - 400 A 250 - 400 A 250 - 400 A

Setting value 230 plusmn15 Vac 240 A 240 A 300 A 300 A 370 A 370 A

Setting range 400 plusmn15 Vac 100 - 160 A 100 - 160 A 160 - 250 A 160 - 250 A 160 - 250 A 160 - 250 A

Setting value 400 plusmn15 Vac 140 A 140 A 170 A 170 A 220 A 220 A

Order numbersOrder Number STEU 50024 STEU 50023 STEU 63024 STEU 63023 STEU 80048 STEU 80024

+-Transformers Control transformers1

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 80023 STEU 100048 STEU 100024 STEU 100023 STEU 160023 STEU 200023

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x115 Vac 2x24 Vac 2x12 Vac 2x115 Vac 2x115 Vac 2x115 Vac

Rated power VDE (DB cos phi=1) 800 VA 1000 VA 1000 VA 1000 VA 1600 VA 2000 VA

Rated power VDE (KB cos phi=05) 3400 VA 5000 VA 5000 VA 5000 VA 7800 VA 10900 VA

No-load voltage (app x factor) 103 103 103 103 101 102

Efficiency 94 94 94 94 94 94

StandardsClassification Control- and isolating

transformerControl- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 250 - 400 A 400 - 630 A 400 - 630 A 400 - 630 A 630 - 1000 A 800 - 1000 A

Setting value 230 plusmn15 Vac 370 A 460 A 460 A 460 A 730 A 910 A

Setting range 400 plusmn15 Vac 160 - 250 A 250 - 400 A 250 - 400 A 250 - 400 A 400 - 630 A 400 - 630 A

Setting value 400 plusmn15 Vac 220 A 270 A 270 A 270 A 420 A 520 A

Order numbersOrder Number STEU 80023 STEU 100048 STEU 100024 STEU 100023 STEU 160023 STEU 200023

+-

BLOCKWebsite

11

12

51

13

21

22

31

32

33

52

40

Subject to change 35

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 80023 STEU 100048 STEU 100024 STEU 100023 STEU 160023 STEU 200023

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x115 Vac 2x24 Vac 2x12 Vac 2x115 Vac 2x115 Vac 2x115 Vac

Rated power VDE (DB cos phi=1) 800 VA 1000 VA 1000 VA 1000 VA 1600 VA 2000 VA

Rated power VDE (KB cos phi=05) 3400 VA 5000 VA 5000 VA 5000 VA 7800 VA 10900 VA

No-load voltage (app x factor) 103 103 103 103 101 102

Efficiency 94 94 94 94 94 94

StandardsClassification Control- and isolating

transformerControl- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 250 - 400 A 400 - 630 A 400 - 630 A 400 - 630 A 630 - 1000 A 800 - 1000 A

Setting value 230 plusmn15 Vac 370 A 460 A 460 A 460 A 730 A 910 A

Setting range 400 plusmn15 Vac 160 - 250 A 250 - 400 A 250 - 400 A 250 - 400 A 400 - 630 A 400 - 630 A

Setting value 400 plusmn15 Vac 220 A 270 A 270 A 270 A 420 A 520 A

Order numbersOrder Number STEU 80023 STEU 100048 STEU 100024 STEU 100023 STEU 160023 STEU 200023

+-Transformers Control transformers1

BLOCKWebsite

36 Subject to change

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 250023

InputRated input voltage 230400 Vac

Tappings Input plusmn15 V

Frequency range 50 - 60 Hz

OutputRated output voltage 2x115 Vac

Rated power VDE (DB cos phi=1) 2500 VA

Rated power VDE (KB cos phi=05) 12400 VA

No-load voltage (app x factor) 102

Efficiency 94

StandardsClassification Control- and isolating

transformer

ApprovalsApprovals cURus

EnvironmentAmbient temperature max 40 degC

Cooling method self-cooling

Safety and protectionType Open type

Class of Insulation System VDE=B UL=class 130

Protection index IP 00

Safety class (prepared) I

Short circuit strength non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 1000 - 1600 A

Setting value 230 plusmn15 Vac 1120 A

Setting range 400 plusmn15 Vac 630 - 1000 A

Setting value 400 plusmn15 Vac 650 A

Order numbersOrder Number STEU 250023

+-Transformers Control transformers1

Control- and safety isolating- resp isolatingtransformerSTEU

Typ

Term

inals

Fixing

met

hod

Fixing

scr

ews

Weig

ht

Dim

ensio

n pic

ture

(in

mm

)

A B C D E F

STEU 6348 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6324 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6323 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 10048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 16048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 25048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 25024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 102 104 84 87 625

STEU 25023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 32048 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32024 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32023 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 40024 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 40023 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 50048 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50024 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50023 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 63024 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 113 143 122 91 59STEU 63023 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 117 148 122 91 59STEU 80048 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80024 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80023 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 100048 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 100024 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 180 185 122 134 82STEU 100023 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 160023 Spring terminal PE 63 x 08 Base plate M8 2100 kg 2 192 161 185 155 133 80STEU 200023 Spring terminal PE 63 x 08 Base plate M8 2550 kg 2 192 183 185 156 155 91STEU 250023 Spring terminal PE 63 x 08 Base plate M8 2700 kg 2 192 190 185 156 161 94

30

Dimension pictures

BLOCKWebsite

11

12

51

13

21

22

31

32

33

52

40

Subject to change 37

Control- and safety isolating- resp isolatingtransformerSTEU

Typ

Term

inals

Fixing

met

hod

Fixing

scr

ews

Weig

ht

Dim

ensio

n pic

ture

(in

mm

)

A B C D E F

STEU 6348 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6324 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6323 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 10048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 16048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 25048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 25024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 102 104 84 87 625

STEU 25023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 32048 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32024 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32023 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 40024 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 40023 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 50048 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50024 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50023 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 63024 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 113 143 122 91 59STEU 63023 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 117 148 122 91 59STEU 80048 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80024 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80023 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 100048 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 100024 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 180 185 122 134 82STEU 100023 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 160023 Spring terminal PE 63 x 08 Base plate M8 2100 kg 2 192 161 185 155 133 80STEU 200023 Spring terminal PE 63 x 08 Base plate M8 2550 kg 2 192 183 185 156 155 91STEU 250023 Spring terminal PE 63 x 08 Base plate M8 2700 kg 2 192 190 185 156 161 94

30

Dimension pictures

Transformers Control transformers1

BLOCKWebsite

Page 2: 1 Control transformers Transformers · 2019. 10. 12. · to: VDE 0570 Part2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4, UL 5085-1/-2, CSA 22.2 No.66 UL 5085-1/-2, CSA 22.2 No.66

11

12

51

13

21

22

31

32

33

52

40

Subject to change 31

Control- and safety isolating- resp isolatingtransformerSTEU

General Data

Rated input voltage 230 and 400 Vac

Rated output voltage 24 - 230 Vac

Rated power 63 - 2500 VA

Insulation class B

Maximum ambient temperature 40 degC

Efficiency up to 94

Degree of protection IP 00

Advantages

Dual input voltage 230 and 400 Vac

Very good switch-on behaviour thanks to reduced starting currents

High performance for the volume thanks to compact design

Primary side plusmn15 V tappings for voltage adjustment

Very good corrosion protection and low noise thanks to BLOCKIMPEXvacuum impregnation

Quick to cable up thanks to the use of spring-clamp terminals

Contact protected screw connection terminals complying with UVV BGV A3

Simple mounting thanks to robust metal footplate with oval slots

Up to 250 VA with combination footplate for bolted and rail mounting

Applications

As a control transformer for the electrical isolation of the input and outputsides The construction of the transformer to supply control systems accordingto VDE 0113 is designed

As an isolating transformer for the safe electrical isolation of the input andoutput sides The transformer may be used to set up protective separation as aprotective measure in accordance with VDE 0100

As a safety transformer for the safe electrical isolation of the input and outputsides The transformer is suitable for creating SELV and PELV circuits becauseof the limit on the output voltage

Sample application

Standards 2 | Z

Approvals W J Z

Control transformerto VDE 0570 Teil 2-2 DIN EN 61558-2-2 EN 61558-2-2 IEC 61558-2-2UL 5085-1-2 CSA 222 No66 Safety isolating transformerto VDE 0570 Teil 2-6 DIN EN 61558-2-6 EN 61558-2-6 IEC 61558-2-6 UL5085-1-2 CSA 222 No66 Isolating transformerto VDE 0570 Part2-4 DIN EN 61558-2-4 EN 61558-2-4 IEC 61558-2-4 UL5085-1-2 CSA 222 No66

UL 5085-1-2 CSA 222 No66

Control- and safety isolating- resp isolatingtransformerSTEU

General Data

Rated input voltage 230 and 400 Vac

Rated output voltage 24 - 230 Vac

Rated power 63 - 2500 VA

Insulation class B

Maximum ambient temperature 40 degC

Efficiency up to 94

Degree of protection IP 00

Advantages

Dual input voltage 230 and 400 Vac

Very good switch-on behaviour thanks to reduced starting currents

High performance for the volume thanks to compact design

Primary side plusmn15 V tappings for voltage adjustment

Very good corrosion protection and low noise thanks to BLOCKIMPEXvacuum impregnation

Quick to cable up thanks to the use of spring-clamp terminals

Contact protected screw connection terminals complying with UVV BGV A3

Simple mounting thanks to robust metal footplate with oval slots

Up to 250 VA with combination footplate for bolted and rail mounting

Applications

As a control transformer for the electrical isolation of the input and outputsides The construction of the transformer to supply control systems accordingto VDE 0113 is designed

As an isolating transformer for the safe electrical isolation of the input andoutput sides The transformer may be used to set up protective separation as aprotective measure in accordance with VDE 0100

As a safety transformer for the safe electrical isolation of the input and outputsides The transformer is suitable for creating SELV and PELV circuits becauseof the limit on the output voltage

Sample application

Standards 2 | Z

Approvals W J Z

Control transformerto VDE 0570 Teil 2-2 DIN EN 61558-2-2 EN 61558-2-2 IEC 61558-2-2UL 5085-1-2 CSA 222 No66 Safety isolating transformerto VDE 0570 Teil 2-6 DIN EN 61558-2-6 EN 61558-2-6 IEC 61558-2-6 UL5085-1-2 CSA 222 No66 Isolating transformerto VDE 0570 Part2-4 DIN EN 61558-2-4 EN 61558-2-4 IEC 61558-2-4 UL5085-1-2 CSA 222 No66

UL 5085-1-2 CSA 222 No66

Control- and safety isolating- resp isolatingtransformerSTEU

General Data

Rated input voltage 230 and 400 Vac

Rated output voltage 24 - 230 Vac

Rated power 63 - 2500 VA

Insulation class B

Maximum ambient temperature 40 degC

Efficiency up to 94

Degree of protection IP 00

Advantages

Dual input voltage 230 and 400 Vac

Very good switch-on behaviour thanks to reduced starting currents

High performance for the volume thanks to compact design

Primary side plusmn15 V tappings for voltage adjustment

Very good corrosion protection and low noise thanks to BLOCKIMPEXvacuum impregnation

Quick to cable up thanks to the use of spring-clamp terminals

Contact protected screw connection terminals complying with UVV BGV A3

Simple mounting thanks to robust metal footplate with oval slots

Up to 250 VA with combination footplate for bolted and rail mounting

Applications

As a control transformer for the electrical isolation of the input and outputsides The construction of the transformer to supply control systems accordingto VDE 0113 is designed

As an isolating transformer for the safe electrical isolation of the input andoutput sides The transformer may be used to set up protective separation as aprotective measure in accordance with VDE 0100

As a safety transformer for the safe electrical isolation of the input and outputsides The transformer is suitable for creating SELV and PELV circuits becauseof the limit on the output voltage

Sample application

Standards 2 | Z

Approvals W J Z

Control transformerto VDE 0570 Teil 2-2 DIN EN 61558-2-2 EN 61558-2-2 IEC 61558-2-2UL 5085-1-2 CSA 222 No66 Safety isolating transformerto VDE 0570 Teil 2-6 DIN EN 61558-2-6 EN 61558-2-6 IEC 61558-2-6 UL5085-1-2 CSA 222 No66 Isolating transformerto VDE 0570 Part2-4 DIN EN 61558-2-4 EN 61558-2-4 IEC 61558-2-4 UL5085-1-2 CSA 222 No66

UL 5085-1-2 CSA 222 No66

Control- and safety isolating- resp isolatingtransformerSTEU

General Data

Rated input voltage 230 and 400 Vac

Rated output voltage 24 - 230 Vac

Rated power 63 - 2500 VA

Insulation class B

Maximum ambient temperature 40 degC

Efficiency up to 94

Degree of protection IP 00

Advantages

Dual input voltage 230 and 400 Vac

Very good switch-on behaviour thanks to reduced starting currents

High performance for the volume thanks to compact design

Primary side plusmn15 V tappings for voltage adjustment

Very good corrosion protection and low noise thanks to BLOCKIMPEXvacuum impregnation

Quick to cable up thanks to the use of spring-clamp terminals

Contact protected screw connection terminals complying with UVV BGV A3

Simple mounting thanks to robust metal footplate with oval slots

Up to 250 VA with combination footplate for bolted and rail mounting

Applications

As a control transformer for the electrical isolation of the input and outputsides The construction of the transformer to supply control systems accordingto VDE 0113 is designed

As an isolating transformer for the safe electrical isolation of the input andoutput sides The transformer may be used to set up protective separation as aprotective measure in accordance with VDE 0100

As a safety transformer for the safe electrical isolation of the input and outputsides The transformer is suitable for creating SELV and PELV circuits becauseof the limit on the output voltage

Sample application

Standards 2 | Z

Approvals W J Z

Control transformerto VDE 0570 Teil 2-2 DIN EN 61558-2-2 EN 61558-2-2 IEC 61558-2-2UL 5085-1-2 CSA 222 No66 Safety isolating transformerto VDE 0570 Teil 2-6 DIN EN 61558-2-6 EN 61558-2-6 IEC 61558-2-6 UL5085-1-2 CSA 222 No66 Isolating transformerto VDE 0570 Part2-4 DIN EN 61558-2-4 EN 61558-2-4 IEC 61558-2-4 UL5085-1-2 CSA 222 No66

UL 5085-1-2 CSA 222 No66

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 6348 STEU 6324 STEU 6323 STEU 10048 STEU 10024 STEU 10023

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x24 Vac 2x12 Vac 2x115 Vac 2x24 Vac 2x12 Vac 2x115 Vac

Rated power VDE (DB cos phi=1) 63 VA 63 VA 63 VA 100 VA 100 VA 100 VA

Rated power VDE (KB cos phi=05) 175 VA 175 VA 175 VA 310 VA 310 VA 175 VA

No-load voltage (app x factor) 110 110 110 107 107 107

Efficiency 86 86 86 86 86 86

StandardsClassification Control- and safety isolating

transformerControl- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 025 - 040 A 025 - 040 A 025 - 040 A 040 - 063 A 040 - 063 A 040 - 063 A

Setting value 230 plusmn15 Vac 035 A 035 A 035 A 050 A 050 A 050 A

Setting range 400 plusmn15 Vac 016 - 025 A 016 - 025 A 016 - 025 A 025 - 040 A 025 - 040 A 025 - 040 A

Setting value 400 plusmn15 Vac 020 A 020 A 020 A 029 A 029 A 029 A

Order numbersOrder Number STEU 6348 STEU 6324 STEU 6323 STEU 10048 STEU 10024 STEU 10023

+-Transformers Control transformers1

BLOCKWebsite

32 Subject to change

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 16048 STEU 16024 STEU 16023 STEU 25048 STEU 25024 STEU 25023

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x24 Vac 2x12 Vac 2x115 Vac 2x24 Vac 2x12 Vac 2x115 Vac

Rated power VDE (DB cos phi=1) 160 VA 160 VA 160 VA 250 VA 250 VA 250 VA

Rated power VDE (KB cos phi=05) 490 VA 490 VA 490 VA 850 VA 850 VA 850 VA

No-load voltage (app x factor) 110 110 110 107 107 107

Efficiency 86 86 86 88 88 88

StandardsClassification Control- and isolating

transformerControl- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 063 - 100 A 063 - 100 A 063 - 100 A 100 - 160 A 100 - 160 A 100 - 160 A

Setting value 230 plusmn15 Vac 080 A 080 A 080 A 120 A 120 A 120 A

Setting range 400 plusmn15 Vac 040 - 063 A 040 - 063 A 040 - 063 A 063 - 100 A 063 - 100 A 063 - 100 A

Setting value 400 plusmn15 Vac 046 A 046 A 046 A 070 A 070 A 070 A

Order numbersOrder Number STEU 16048 STEU 16024 STEU 16023 STEU 25048 STEU 25024 STEU 25023

+-Transformers Control transformers1

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 32048 STEU 32024 STEU 32023 STEU 40024 STEU 40023 STEU 50048

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x24 Vac 2x12 Vac 2x115 Vac 2x12 Vac 2x115 Vac 2x24 Vac

Rated power VDE (DB cos phi=1) 320 VA 320 VA 320 VA 400 VA 400 VA 500 VA

Rated power VDE (KB cos phi=05) 1120 VA 1120 VA 1120 VA 1440 VA 1440 VA 2000 VA

No-load voltage (app x factor) 107 107 107 104 104 104

Efficiency 90 90 90 90 90 92

StandardsClassification Control- and isolating

transformerControl- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 100 - 160 A 100 - 160 A 100 - 160 A 160 - 250 A 160 - 250 A 160 - 250 A

Setting value 230 plusmn15 Vac 150 A 150 A 150 A 190 A 190 A 240 A

Setting range 400 plusmn15 Vac 063 - 100 A 063 - 100 A 063 - 100 A 100 - 160 A 100 - 160 A 100 - 160 A

Setting value 400 plusmn15 Vac 088 A 088 A 088 A 110 A 110 A 140 A

Order numbersOrder Number STEU 32048 STEU 32024 STEU 32023 STEU 40024 STEU 40023 STEU 50048

+-

BLOCKWebsite

11

12

51

13

21

22

31

32

33

52

40

Subject to change 33

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 32048 STEU 32024 STEU 32023 STEU 40024 STEU 40023 STEU 50048

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x24 Vac 2x12 Vac 2x115 Vac 2x12 Vac 2x115 Vac 2x24 Vac

Rated power VDE (DB cos phi=1) 320 VA 320 VA 320 VA 400 VA 400 VA 500 VA

Rated power VDE (KB cos phi=05) 1120 VA 1120 VA 1120 VA 1440 VA 1440 VA 2000 VA

No-load voltage (app x factor) 107 107 107 104 104 104

Efficiency 90 90 90 90 90 92

StandardsClassification Control- and isolating

transformerControl- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 100 - 160 A 100 - 160 A 100 - 160 A 160 - 250 A 160 - 250 A 160 - 250 A

Setting value 230 plusmn15 Vac 150 A 150 A 150 A 190 A 190 A 240 A

Setting range 400 plusmn15 Vac 063 - 100 A 063 - 100 A 063 - 100 A 100 - 160 A 100 - 160 A 100 - 160 A

Setting value 400 plusmn15 Vac 088 A 088 A 088 A 110 A 110 A 140 A

Order numbersOrder Number STEU 32048 STEU 32024 STEU 32023 STEU 40024 STEU 40023 STEU 50048

+-Transformers Control transformers1

BLOCKWebsite

34 Subject to change

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 50024 STEU 50023 STEU 63024 STEU 63023 STEU 80048 STEU 80024

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x12 Vac 2x115 Vac 2x12 Vac 2x115 Vac 2x24 Vac 2x12 Vac

Rated power VDE (DB cos phi=1) 500 VA 500 VA 630 VA 630 VA 800 VA 800 VA

Rated power VDE (KB cos phi=05) 2000 VA 2000 VA 2350 VA 2350 VA 3400 VA 3400 VA

No-load voltage (app x factor) 104 104 104 104 103 103

Efficiency 92 92 92 92 94 94

StandardsClassification Control- and safety isolating

transformerControl- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

Control- and safety isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 160 - 250 A 160 - 250 A 250 - 400 A 250 - 400 A 250 - 400 A 250 - 400 A

Setting value 230 plusmn15 Vac 240 A 240 A 300 A 300 A 370 A 370 A

Setting range 400 plusmn15 Vac 100 - 160 A 100 - 160 A 160 - 250 A 160 - 250 A 160 - 250 A 160 - 250 A

Setting value 400 plusmn15 Vac 140 A 140 A 170 A 170 A 220 A 220 A

Order numbersOrder Number STEU 50024 STEU 50023 STEU 63024 STEU 63023 STEU 80048 STEU 80024

+-Transformers Control transformers1

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 80023 STEU 100048 STEU 100024 STEU 100023 STEU 160023 STEU 200023

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x115 Vac 2x24 Vac 2x12 Vac 2x115 Vac 2x115 Vac 2x115 Vac

Rated power VDE (DB cos phi=1) 800 VA 1000 VA 1000 VA 1000 VA 1600 VA 2000 VA

Rated power VDE (KB cos phi=05) 3400 VA 5000 VA 5000 VA 5000 VA 7800 VA 10900 VA

No-load voltage (app x factor) 103 103 103 103 101 102

Efficiency 94 94 94 94 94 94

StandardsClassification Control- and isolating

transformerControl- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 250 - 400 A 400 - 630 A 400 - 630 A 400 - 630 A 630 - 1000 A 800 - 1000 A

Setting value 230 plusmn15 Vac 370 A 460 A 460 A 460 A 730 A 910 A

Setting range 400 plusmn15 Vac 160 - 250 A 250 - 400 A 250 - 400 A 250 - 400 A 400 - 630 A 400 - 630 A

Setting value 400 plusmn15 Vac 220 A 270 A 270 A 270 A 420 A 520 A

Order numbersOrder Number STEU 80023 STEU 100048 STEU 100024 STEU 100023 STEU 160023 STEU 200023

+-

BLOCKWebsite

11

12

51

13

21

22

31

32

33

52

40

Subject to change 35

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 80023 STEU 100048 STEU 100024 STEU 100023 STEU 160023 STEU 200023

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x115 Vac 2x24 Vac 2x12 Vac 2x115 Vac 2x115 Vac 2x115 Vac

Rated power VDE (DB cos phi=1) 800 VA 1000 VA 1000 VA 1000 VA 1600 VA 2000 VA

Rated power VDE (KB cos phi=05) 3400 VA 5000 VA 5000 VA 5000 VA 7800 VA 10900 VA

No-load voltage (app x factor) 103 103 103 103 101 102

Efficiency 94 94 94 94 94 94

StandardsClassification Control- and isolating

transformerControl- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 250 - 400 A 400 - 630 A 400 - 630 A 400 - 630 A 630 - 1000 A 800 - 1000 A

Setting value 230 plusmn15 Vac 370 A 460 A 460 A 460 A 730 A 910 A

Setting range 400 plusmn15 Vac 160 - 250 A 250 - 400 A 250 - 400 A 250 - 400 A 400 - 630 A 400 - 630 A

Setting value 400 plusmn15 Vac 220 A 270 A 270 A 270 A 420 A 520 A

Order numbersOrder Number STEU 80023 STEU 100048 STEU 100024 STEU 100023 STEU 160023 STEU 200023

+-Transformers Control transformers1

BLOCKWebsite

36 Subject to change

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 250023

InputRated input voltage 230400 Vac

Tappings Input plusmn15 V

Frequency range 50 - 60 Hz

OutputRated output voltage 2x115 Vac

Rated power VDE (DB cos phi=1) 2500 VA

Rated power VDE (KB cos phi=05) 12400 VA

No-load voltage (app x factor) 102

Efficiency 94

StandardsClassification Control- and isolating

transformer

ApprovalsApprovals cURus

EnvironmentAmbient temperature max 40 degC

Cooling method self-cooling

Safety and protectionType Open type

Class of Insulation System VDE=B UL=class 130

Protection index IP 00

Safety class (prepared) I

Short circuit strength non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 1000 - 1600 A

Setting value 230 plusmn15 Vac 1120 A

Setting range 400 plusmn15 Vac 630 - 1000 A

Setting value 400 plusmn15 Vac 650 A

Order numbersOrder Number STEU 250023

+-Transformers Control transformers1

Control- and safety isolating- resp isolatingtransformerSTEU

Typ

Term

inals

Fixing

met

hod

Fixing

scr

ews

Weig

ht

Dim

ensio

n pic

ture

(in

mm

)

A B C D E F

STEU 6348 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6324 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6323 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 10048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 16048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 25048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 25024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 102 104 84 87 625

STEU 25023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 32048 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32024 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32023 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 40024 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 40023 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 50048 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50024 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50023 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 63024 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 113 143 122 91 59STEU 63023 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 117 148 122 91 59STEU 80048 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80024 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80023 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 100048 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 100024 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 180 185 122 134 82STEU 100023 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 160023 Spring terminal PE 63 x 08 Base plate M8 2100 kg 2 192 161 185 155 133 80STEU 200023 Spring terminal PE 63 x 08 Base plate M8 2550 kg 2 192 183 185 156 155 91STEU 250023 Spring terminal PE 63 x 08 Base plate M8 2700 kg 2 192 190 185 156 161 94

30

Dimension pictures

BLOCKWebsite

11

12

51

13

21

22

31

32

33

52

40

Subject to change 37

Control- and safety isolating- resp isolatingtransformerSTEU

Typ

Term

inals

Fixing

met

hod

Fixing

scr

ews

Weig

ht

Dim

ensio

n pic

ture

(in

mm

)

A B C D E F

STEU 6348 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6324 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6323 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 10048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 16048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 25048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 25024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 102 104 84 87 625

STEU 25023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 32048 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32024 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32023 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 40024 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 40023 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 50048 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50024 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50023 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 63024 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 113 143 122 91 59STEU 63023 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 117 148 122 91 59STEU 80048 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80024 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80023 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 100048 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 100024 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 180 185 122 134 82STEU 100023 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 160023 Spring terminal PE 63 x 08 Base plate M8 2100 kg 2 192 161 185 155 133 80STEU 200023 Spring terminal PE 63 x 08 Base plate M8 2550 kg 2 192 183 185 156 155 91STEU 250023 Spring terminal PE 63 x 08 Base plate M8 2700 kg 2 192 190 185 156 161 94

30

Dimension pictures

Transformers Control transformers1

BLOCKWebsite

Page 3: 1 Control transformers Transformers · 2019. 10. 12. · to: VDE 0570 Part2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4, UL 5085-1/-2, CSA 22.2 No.66 UL 5085-1/-2, CSA 22.2 No.66

32 Subject to change

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 16048 STEU 16024 STEU 16023 STEU 25048 STEU 25024 STEU 25023

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x24 Vac 2x12 Vac 2x115 Vac 2x24 Vac 2x12 Vac 2x115 Vac

Rated power VDE (DB cos phi=1) 160 VA 160 VA 160 VA 250 VA 250 VA 250 VA

Rated power VDE (KB cos phi=05) 490 VA 490 VA 490 VA 850 VA 850 VA 850 VA

No-load voltage (app x factor) 110 110 110 107 107 107

Efficiency 86 86 86 88 88 88

StandardsClassification Control- and isolating

transformerControl- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 063 - 100 A 063 - 100 A 063 - 100 A 100 - 160 A 100 - 160 A 100 - 160 A

Setting value 230 plusmn15 Vac 080 A 080 A 080 A 120 A 120 A 120 A

Setting range 400 plusmn15 Vac 040 - 063 A 040 - 063 A 040 - 063 A 063 - 100 A 063 - 100 A 063 - 100 A

Setting value 400 plusmn15 Vac 046 A 046 A 046 A 070 A 070 A 070 A

Order numbersOrder Number STEU 16048 STEU 16024 STEU 16023 STEU 25048 STEU 25024 STEU 25023

+-Transformers Control transformers1

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 32048 STEU 32024 STEU 32023 STEU 40024 STEU 40023 STEU 50048

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x24 Vac 2x12 Vac 2x115 Vac 2x12 Vac 2x115 Vac 2x24 Vac

Rated power VDE (DB cos phi=1) 320 VA 320 VA 320 VA 400 VA 400 VA 500 VA

Rated power VDE (KB cos phi=05) 1120 VA 1120 VA 1120 VA 1440 VA 1440 VA 2000 VA

No-load voltage (app x factor) 107 107 107 104 104 104

Efficiency 90 90 90 90 90 92

StandardsClassification Control- and isolating

transformerControl- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 100 - 160 A 100 - 160 A 100 - 160 A 160 - 250 A 160 - 250 A 160 - 250 A

Setting value 230 plusmn15 Vac 150 A 150 A 150 A 190 A 190 A 240 A

Setting range 400 plusmn15 Vac 063 - 100 A 063 - 100 A 063 - 100 A 100 - 160 A 100 - 160 A 100 - 160 A

Setting value 400 plusmn15 Vac 088 A 088 A 088 A 110 A 110 A 140 A

Order numbersOrder Number STEU 32048 STEU 32024 STEU 32023 STEU 40024 STEU 40023 STEU 50048

+-

BLOCKWebsite

11

12

51

13

21

22

31

32

33

52

40

Subject to change 33

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 32048 STEU 32024 STEU 32023 STEU 40024 STEU 40023 STEU 50048

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x24 Vac 2x12 Vac 2x115 Vac 2x12 Vac 2x115 Vac 2x24 Vac

Rated power VDE (DB cos phi=1) 320 VA 320 VA 320 VA 400 VA 400 VA 500 VA

Rated power VDE (KB cos phi=05) 1120 VA 1120 VA 1120 VA 1440 VA 1440 VA 2000 VA

No-load voltage (app x factor) 107 107 107 104 104 104

Efficiency 90 90 90 90 90 92

StandardsClassification Control- and isolating

transformerControl- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 100 - 160 A 100 - 160 A 100 - 160 A 160 - 250 A 160 - 250 A 160 - 250 A

Setting value 230 plusmn15 Vac 150 A 150 A 150 A 190 A 190 A 240 A

Setting range 400 plusmn15 Vac 063 - 100 A 063 - 100 A 063 - 100 A 100 - 160 A 100 - 160 A 100 - 160 A

Setting value 400 plusmn15 Vac 088 A 088 A 088 A 110 A 110 A 140 A

Order numbersOrder Number STEU 32048 STEU 32024 STEU 32023 STEU 40024 STEU 40023 STEU 50048

+-Transformers Control transformers1

BLOCKWebsite

34 Subject to change

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 50024 STEU 50023 STEU 63024 STEU 63023 STEU 80048 STEU 80024

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x12 Vac 2x115 Vac 2x12 Vac 2x115 Vac 2x24 Vac 2x12 Vac

Rated power VDE (DB cos phi=1) 500 VA 500 VA 630 VA 630 VA 800 VA 800 VA

Rated power VDE (KB cos phi=05) 2000 VA 2000 VA 2350 VA 2350 VA 3400 VA 3400 VA

No-load voltage (app x factor) 104 104 104 104 103 103

Efficiency 92 92 92 92 94 94

StandardsClassification Control- and safety isolating

transformerControl- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

Control- and safety isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 160 - 250 A 160 - 250 A 250 - 400 A 250 - 400 A 250 - 400 A 250 - 400 A

Setting value 230 plusmn15 Vac 240 A 240 A 300 A 300 A 370 A 370 A

Setting range 400 plusmn15 Vac 100 - 160 A 100 - 160 A 160 - 250 A 160 - 250 A 160 - 250 A 160 - 250 A

Setting value 400 plusmn15 Vac 140 A 140 A 170 A 170 A 220 A 220 A

Order numbersOrder Number STEU 50024 STEU 50023 STEU 63024 STEU 63023 STEU 80048 STEU 80024

+-Transformers Control transformers1

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 80023 STEU 100048 STEU 100024 STEU 100023 STEU 160023 STEU 200023

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x115 Vac 2x24 Vac 2x12 Vac 2x115 Vac 2x115 Vac 2x115 Vac

Rated power VDE (DB cos phi=1) 800 VA 1000 VA 1000 VA 1000 VA 1600 VA 2000 VA

Rated power VDE (KB cos phi=05) 3400 VA 5000 VA 5000 VA 5000 VA 7800 VA 10900 VA

No-load voltage (app x factor) 103 103 103 103 101 102

Efficiency 94 94 94 94 94 94

StandardsClassification Control- and isolating

transformerControl- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 250 - 400 A 400 - 630 A 400 - 630 A 400 - 630 A 630 - 1000 A 800 - 1000 A

Setting value 230 plusmn15 Vac 370 A 460 A 460 A 460 A 730 A 910 A

Setting range 400 plusmn15 Vac 160 - 250 A 250 - 400 A 250 - 400 A 250 - 400 A 400 - 630 A 400 - 630 A

Setting value 400 plusmn15 Vac 220 A 270 A 270 A 270 A 420 A 520 A

Order numbersOrder Number STEU 80023 STEU 100048 STEU 100024 STEU 100023 STEU 160023 STEU 200023

+-

BLOCKWebsite

11

12

51

13

21

22

31

32

33

52

40

Subject to change 35

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 80023 STEU 100048 STEU 100024 STEU 100023 STEU 160023 STEU 200023

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x115 Vac 2x24 Vac 2x12 Vac 2x115 Vac 2x115 Vac 2x115 Vac

Rated power VDE (DB cos phi=1) 800 VA 1000 VA 1000 VA 1000 VA 1600 VA 2000 VA

Rated power VDE (KB cos phi=05) 3400 VA 5000 VA 5000 VA 5000 VA 7800 VA 10900 VA

No-load voltage (app x factor) 103 103 103 103 101 102

Efficiency 94 94 94 94 94 94

StandardsClassification Control- and isolating

transformerControl- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 250 - 400 A 400 - 630 A 400 - 630 A 400 - 630 A 630 - 1000 A 800 - 1000 A

Setting value 230 plusmn15 Vac 370 A 460 A 460 A 460 A 730 A 910 A

Setting range 400 plusmn15 Vac 160 - 250 A 250 - 400 A 250 - 400 A 250 - 400 A 400 - 630 A 400 - 630 A

Setting value 400 plusmn15 Vac 220 A 270 A 270 A 270 A 420 A 520 A

Order numbersOrder Number STEU 80023 STEU 100048 STEU 100024 STEU 100023 STEU 160023 STEU 200023

+-Transformers Control transformers1

BLOCKWebsite

36 Subject to change

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 250023

InputRated input voltage 230400 Vac

Tappings Input plusmn15 V

Frequency range 50 - 60 Hz

OutputRated output voltage 2x115 Vac

Rated power VDE (DB cos phi=1) 2500 VA

Rated power VDE (KB cos phi=05) 12400 VA

No-load voltage (app x factor) 102

Efficiency 94

StandardsClassification Control- and isolating

transformer

ApprovalsApprovals cURus

EnvironmentAmbient temperature max 40 degC

Cooling method self-cooling

Safety and protectionType Open type

Class of Insulation System VDE=B UL=class 130

Protection index IP 00

Safety class (prepared) I

Short circuit strength non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 1000 - 1600 A

Setting value 230 plusmn15 Vac 1120 A

Setting range 400 plusmn15 Vac 630 - 1000 A

Setting value 400 plusmn15 Vac 650 A

Order numbersOrder Number STEU 250023

+-Transformers Control transformers1

Control- and safety isolating- resp isolatingtransformerSTEU

Typ

Term

inals

Fixing

met

hod

Fixing

scr

ews

Weig

ht

Dim

ensio

n pic

ture

(in

mm

)

A B C D E F

STEU 6348 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6324 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6323 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 10048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 16048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 25048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 25024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 102 104 84 87 625

STEU 25023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 32048 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32024 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32023 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 40024 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 40023 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 50048 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50024 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50023 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 63024 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 113 143 122 91 59STEU 63023 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 117 148 122 91 59STEU 80048 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80024 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80023 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 100048 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 100024 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 180 185 122 134 82STEU 100023 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 160023 Spring terminal PE 63 x 08 Base plate M8 2100 kg 2 192 161 185 155 133 80STEU 200023 Spring terminal PE 63 x 08 Base plate M8 2550 kg 2 192 183 185 156 155 91STEU 250023 Spring terminal PE 63 x 08 Base plate M8 2700 kg 2 192 190 185 156 161 94

30

Dimension pictures

BLOCKWebsite

11

12

51

13

21

22

31

32

33

52

40

Subject to change 37

Control- and safety isolating- resp isolatingtransformerSTEU

Typ

Term

inals

Fixing

met

hod

Fixing

scr

ews

Weig

ht

Dim

ensio

n pic

ture

(in

mm

)

A B C D E F

STEU 6348 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6324 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6323 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 10048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 16048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 25048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 25024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 102 104 84 87 625

STEU 25023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 32048 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32024 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32023 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 40024 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 40023 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 50048 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50024 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50023 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 63024 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 113 143 122 91 59STEU 63023 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 117 148 122 91 59STEU 80048 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80024 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80023 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 100048 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 100024 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 180 185 122 134 82STEU 100023 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 160023 Spring terminal PE 63 x 08 Base plate M8 2100 kg 2 192 161 185 155 133 80STEU 200023 Spring terminal PE 63 x 08 Base plate M8 2550 kg 2 192 183 185 156 155 91STEU 250023 Spring terminal PE 63 x 08 Base plate M8 2700 kg 2 192 190 185 156 161 94

30

Dimension pictures

Transformers Control transformers1

BLOCKWebsite

Page 4: 1 Control transformers Transformers · 2019. 10. 12. · to: VDE 0570 Part2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4, UL 5085-1/-2, CSA 22.2 No.66 UL 5085-1/-2, CSA 22.2 No.66

11

12

51

13

21

22

31

32

33

52

40

Subject to change 33

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 32048 STEU 32024 STEU 32023 STEU 40024 STEU 40023 STEU 50048

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x24 Vac 2x12 Vac 2x115 Vac 2x12 Vac 2x115 Vac 2x24 Vac

Rated power VDE (DB cos phi=1) 320 VA 320 VA 320 VA 400 VA 400 VA 500 VA

Rated power VDE (KB cos phi=05) 1120 VA 1120 VA 1120 VA 1440 VA 1440 VA 2000 VA

No-load voltage (app x factor) 107 107 107 104 104 104

Efficiency 90 90 90 90 90 92

StandardsClassification Control- and isolating

transformerControl- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 100 - 160 A 100 - 160 A 100 - 160 A 160 - 250 A 160 - 250 A 160 - 250 A

Setting value 230 plusmn15 Vac 150 A 150 A 150 A 190 A 190 A 240 A

Setting range 400 plusmn15 Vac 063 - 100 A 063 - 100 A 063 - 100 A 100 - 160 A 100 - 160 A 100 - 160 A

Setting value 400 plusmn15 Vac 088 A 088 A 088 A 110 A 110 A 140 A

Order numbersOrder Number STEU 32048 STEU 32024 STEU 32023 STEU 40024 STEU 40023 STEU 50048

+-Transformers Control transformers1

BLOCKWebsite

34 Subject to change

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 50024 STEU 50023 STEU 63024 STEU 63023 STEU 80048 STEU 80024

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x12 Vac 2x115 Vac 2x12 Vac 2x115 Vac 2x24 Vac 2x12 Vac

Rated power VDE (DB cos phi=1) 500 VA 500 VA 630 VA 630 VA 800 VA 800 VA

Rated power VDE (KB cos phi=05) 2000 VA 2000 VA 2350 VA 2350 VA 3400 VA 3400 VA

No-load voltage (app x factor) 104 104 104 104 103 103

Efficiency 92 92 92 92 94 94

StandardsClassification Control- and safety isolating

transformerControl- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

Control- and safety isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 160 - 250 A 160 - 250 A 250 - 400 A 250 - 400 A 250 - 400 A 250 - 400 A

Setting value 230 plusmn15 Vac 240 A 240 A 300 A 300 A 370 A 370 A

Setting range 400 plusmn15 Vac 100 - 160 A 100 - 160 A 160 - 250 A 160 - 250 A 160 - 250 A 160 - 250 A

Setting value 400 plusmn15 Vac 140 A 140 A 170 A 170 A 220 A 220 A

Order numbersOrder Number STEU 50024 STEU 50023 STEU 63024 STEU 63023 STEU 80048 STEU 80024

+-Transformers Control transformers1

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 80023 STEU 100048 STEU 100024 STEU 100023 STEU 160023 STEU 200023

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x115 Vac 2x24 Vac 2x12 Vac 2x115 Vac 2x115 Vac 2x115 Vac

Rated power VDE (DB cos phi=1) 800 VA 1000 VA 1000 VA 1000 VA 1600 VA 2000 VA

Rated power VDE (KB cos phi=05) 3400 VA 5000 VA 5000 VA 5000 VA 7800 VA 10900 VA

No-load voltage (app x factor) 103 103 103 103 101 102

Efficiency 94 94 94 94 94 94

StandardsClassification Control- and isolating

transformerControl- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 250 - 400 A 400 - 630 A 400 - 630 A 400 - 630 A 630 - 1000 A 800 - 1000 A

Setting value 230 plusmn15 Vac 370 A 460 A 460 A 460 A 730 A 910 A

Setting range 400 plusmn15 Vac 160 - 250 A 250 - 400 A 250 - 400 A 250 - 400 A 400 - 630 A 400 - 630 A

Setting value 400 plusmn15 Vac 220 A 270 A 270 A 270 A 420 A 520 A

Order numbersOrder Number STEU 80023 STEU 100048 STEU 100024 STEU 100023 STEU 160023 STEU 200023

+-

BLOCKWebsite

11

12

51

13

21

22

31

32

33

52

40

Subject to change 35

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 80023 STEU 100048 STEU 100024 STEU 100023 STEU 160023 STEU 200023

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x115 Vac 2x24 Vac 2x12 Vac 2x115 Vac 2x115 Vac 2x115 Vac

Rated power VDE (DB cos phi=1) 800 VA 1000 VA 1000 VA 1000 VA 1600 VA 2000 VA

Rated power VDE (KB cos phi=05) 3400 VA 5000 VA 5000 VA 5000 VA 7800 VA 10900 VA

No-load voltage (app x factor) 103 103 103 103 101 102

Efficiency 94 94 94 94 94 94

StandardsClassification Control- and isolating

transformerControl- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 250 - 400 A 400 - 630 A 400 - 630 A 400 - 630 A 630 - 1000 A 800 - 1000 A

Setting value 230 plusmn15 Vac 370 A 460 A 460 A 460 A 730 A 910 A

Setting range 400 plusmn15 Vac 160 - 250 A 250 - 400 A 250 - 400 A 250 - 400 A 400 - 630 A 400 - 630 A

Setting value 400 plusmn15 Vac 220 A 270 A 270 A 270 A 420 A 520 A

Order numbersOrder Number STEU 80023 STEU 100048 STEU 100024 STEU 100023 STEU 160023 STEU 200023

+-Transformers Control transformers1

BLOCKWebsite

36 Subject to change

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 250023

InputRated input voltage 230400 Vac

Tappings Input plusmn15 V

Frequency range 50 - 60 Hz

OutputRated output voltage 2x115 Vac

Rated power VDE (DB cos phi=1) 2500 VA

Rated power VDE (KB cos phi=05) 12400 VA

No-load voltage (app x factor) 102

Efficiency 94

StandardsClassification Control- and isolating

transformer

ApprovalsApprovals cURus

EnvironmentAmbient temperature max 40 degC

Cooling method self-cooling

Safety and protectionType Open type

Class of Insulation System VDE=B UL=class 130

Protection index IP 00

Safety class (prepared) I

Short circuit strength non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 1000 - 1600 A

Setting value 230 plusmn15 Vac 1120 A

Setting range 400 plusmn15 Vac 630 - 1000 A

Setting value 400 plusmn15 Vac 650 A

Order numbersOrder Number STEU 250023

+-Transformers Control transformers1

Control- and safety isolating- resp isolatingtransformerSTEU

Typ

Term

inals

Fixing

met

hod

Fixing

scr

ews

Weig

ht

Dim

ensio

n pic

ture

(in

mm

)

A B C D E F

STEU 6348 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6324 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6323 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 10048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 16048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 25048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 25024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 102 104 84 87 625

STEU 25023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 32048 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32024 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32023 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 40024 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 40023 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 50048 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50024 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50023 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 63024 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 113 143 122 91 59STEU 63023 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 117 148 122 91 59STEU 80048 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80024 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80023 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 100048 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 100024 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 180 185 122 134 82STEU 100023 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 160023 Spring terminal PE 63 x 08 Base plate M8 2100 kg 2 192 161 185 155 133 80STEU 200023 Spring terminal PE 63 x 08 Base plate M8 2550 kg 2 192 183 185 156 155 91STEU 250023 Spring terminal PE 63 x 08 Base plate M8 2700 kg 2 192 190 185 156 161 94

30

Dimension pictures

BLOCKWebsite

11

12

51

13

21

22

31

32

33

52

40

Subject to change 37

Control- and safety isolating- resp isolatingtransformerSTEU

Typ

Term

inals

Fixing

met

hod

Fixing

scr

ews

Weig

ht

Dim

ensio

n pic

ture

(in

mm

)

A B C D E F

STEU 6348 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6324 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6323 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 10048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 16048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 25048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 25024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 102 104 84 87 625

STEU 25023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 32048 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32024 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32023 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 40024 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 40023 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 50048 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50024 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50023 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 63024 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 113 143 122 91 59STEU 63023 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 117 148 122 91 59STEU 80048 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80024 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80023 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 100048 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 100024 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 180 185 122 134 82STEU 100023 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 160023 Spring terminal PE 63 x 08 Base plate M8 2100 kg 2 192 161 185 155 133 80STEU 200023 Spring terminal PE 63 x 08 Base plate M8 2550 kg 2 192 183 185 156 155 91STEU 250023 Spring terminal PE 63 x 08 Base plate M8 2700 kg 2 192 190 185 156 161 94

30

Dimension pictures

Transformers Control transformers1

BLOCKWebsite

Page 5: 1 Control transformers Transformers · 2019. 10. 12. · to: VDE 0570 Part2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4, UL 5085-1/-2, CSA 22.2 No.66 UL 5085-1/-2, CSA 22.2 No.66

34 Subject to change

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 50024 STEU 50023 STEU 63024 STEU 63023 STEU 80048 STEU 80024

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x12 Vac 2x115 Vac 2x12 Vac 2x115 Vac 2x24 Vac 2x12 Vac

Rated power VDE (DB cos phi=1) 500 VA 500 VA 630 VA 630 VA 800 VA 800 VA

Rated power VDE (KB cos phi=05) 2000 VA 2000 VA 2350 VA 2350 VA 3400 VA 3400 VA

No-load voltage (app x factor) 104 104 104 104 103 103

Efficiency 92 92 92 92 94 94

StandardsClassification Control- and safety isolating

transformerControl- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

Control- and safety isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 160 - 250 A 160 - 250 A 250 - 400 A 250 - 400 A 250 - 400 A 250 - 400 A

Setting value 230 plusmn15 Vac 240 A 240 A 300 A 300 A 370 A 370 A

Setting range 400 plusmn15 Vac 100 - 160 A 100 - 160 A 160 - 250 A 160 - 250 A 160 - 250 A 160 - 250 A

Setting value 400 plusmn15 Vac 140 A 140 A 170 A 170 A 220 A 220 A

Order numbersOrder Number STEU 50024 STEU 50023 STEU 63024 STEU 63023 STEU 80048 STEU 80024

+-Transformers Control transformers1

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 80023 STEU 100048 STEU 100024 STEU 100023 STEU 160023 STEU 200023

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x115 Vac 2x24 Vac 2x12 Vac 2x115 Vac 2x115 Vac 2x115 Vac

Rated power VDE (DB cos phi=1) 800 VA 1000 VA 1000 VA 1000 VA 1600 VA 2000 VA

Rated power VDE (KB cos phi=05) 3400 VA 5000 VA 5000 VA 5000 VA 7800 VA 10900 VA

No-load voltage (app x factor) 103 103 103 103 101 102

Efficiency 94 94 94 94 94 94

StandardsClassification Control- and isolating

transformerControl- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 250 - 400 A 400 - 630 A 400 - 630 A 400 - 630 A 630 - 1000 A 800 - 1000 A

Setting value 230 plusmn15 Vac 370 A 460 A 460 A 460 A 730 A 910 A

Setting range 400 plusmn15 Vac 160 - 250 A 250 - 400 A 250 - 400 A 250 - 400 A 400 - 630 A 400 - 630 A

Setting value 400 plusmn15 Vac 220 A 270 A 270 A 270 A 420 A 520 A

Order numbersOrder Number STEU 80023 STEU 100048 STEU 100024 STEU 100023 STEU 160023 STEU 200023

+-

BLOCKWebsite

11

12

51

13

21

22

31

32

33

52

40

Subject to change 35

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 80023 STEU 100048 STEU 100024 STEU 100023 STEU 160023 STEU 200023

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x115 Vac 2x24 Vac 2x12 Vac 2x115 Vac 2x115 Vac 2x115 Vac

Rated power VDE (DB cos phi=1) 800 VA 1000 VA 1000 VA 1000 VA 1600 VA 2000 VA

Rated power VDE (KB cos phi=05) 3400 VA 5000 VA 5000 VA 5000 VA 7800 VA 10900 VA

No-load voltage (app x factor) 103 103 103 103 101 102

Efficiency 94 94 94 94 94 94

StandardsClassification Control- and isolating

transformerControl- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 250 - 400 A 400 - 630 A 400 - 630 A 400 - 630 A 630 - 1000 A 800 - 1000 A

Setting value 230 plusmn15 Vac 370 A 460 A 460 A 460 A 730 A 910 A

Setting range 400 plusmn15 Vac 160 - 250 A 250 - 400 A 250 - 400 A 250 - 400 A 400 - 630 A 400 - 630 A

Setting value 400 plusmn15 Vac 220 A 270 A 270 A 270 A 420 A 520 A

Order numbersOrder Number STEU 80023 STEU 100048 STEU 100024 STEU 100023 STEU 160023 STEU 200023

+-Transformers Control transformers1

BLOCKWebsite

36 Subject to change

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 250023

InputRated input voltage 230400 Vac

Tappings Input plusmn15 V

Frequency range 50 - 60 Hz

OutputRated output voltage 2x115 Vac

Rated power VDE (DB cos phi=1) 2500 VA

Rated power VDE (KB cos phi=05) 12400 VA

No-load voltage (app x factor) 102

Efficiency 94

StandardsClassification Control- and isolating

transformer

ApprovalsApprovals cURus

EnvironmentAmbient temperature max 40 degC

Cooling method self-cooling

Safety and protectionType Open type

Class of Insulation System VDE=B UL=class 130

Protection index IP 00

Safety class (prepared) I

Short circuit strength non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 1000 - 1600 A

Setting value 230 plusmn15 Vac 1120 A

Setting range 400 plusmn15 Vac 630 - 1000 A

Setting value 400 plusmn15 Vac 650 A

Order numbersOrder Number STEU 250023

+-Transformers Control transformers1

Control- and safety isolating- resp isolatingtransformerSTEU

Typ

Term

inals

Fixing

met

hod

Fixing

scr

ews

Weig

ht

Dim

ensio

n pic

ture

(in

mm

)

A B C D E F

STEU 6348 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6324 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6323 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 10048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 16048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 25048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 25024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 102 104 84 87 625

STEU 25023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 32048 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32024 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32023 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 40024 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 40023 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 50048 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50024 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50023 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 63024 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 113 143 122 91 59STEU 63023 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 117 148 122 91 59STEU 80048 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80024 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80023 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 100048 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 100024 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 180 185 122 134 82STEU 100023 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 160023 Spring terminal PE 63 x 08 Base plate M8 2100 kg 2 192 161 185 155 133 80STEU 200023 Spring terminal PE 63 x 08 Base plate M8 2550 kg 2 192 183 185 156 155 91STEU 250023 Spring terminal PE 63 x 08 Base plate M8 2700 kg 2 192 190 185 156 161 94

30

Dimension pictures

BLOCKWebsite

11

12

51

13

21

22

31

32

33

52

40

Subject to change 37

Control- and safety isolating- resp isolatingtransformerSTEU

Typ

Term

inals

Fixing

met

hod

Fixing

scr

ews

Weig

ht

Dim

ensio

n pic

ture

(in

mm

)

A B C D E F

STEU 6348 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6324 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6323 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 10048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 16048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 25048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 25024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 102 104 84 87 625

STEU 25023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 32048 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32024 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32023 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 40024 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 40023 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 50048 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50024 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50023 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 63024 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 113 143 122 91 59STEU 63023 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 117 148 122 91 59STEU 80048 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80024 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80023 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 100048 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 100024 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 180 185 122 134 82STEU 100023 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 160023 Spring terminal PE 63 x 08 Base plate M8 2100 kg 2 192 161 185 155 133 80STEU 200023 Spring terminal PE 63 x 08 Base plate M8 2550 kg 2 192 183 185 156 155 91STEU 250023 Spring terminal PE 63 x 08 Base plate M8 2700 kg 2 192 190 185 156 161 94

30

Dimension pictures

Transformers Control transformers1

BLOCKWebsite

Page 6: 1 Control transformers Transformers · 2019. 10. 12. · to: VDE 0570 Part2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4, UL 5085-1/-2, CSA 22.2 No.66 UL 5085-1/-2, CSA 22.2 No.66

11

12

51

13

21

22

31

32

33

52

40

Subject to change 35

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 80023 STEU 100048 STEU 100024 STEU 100023 STEU 160023 STEU 200023

InputRated input voltage 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac 230400 Vac

Tappings Input plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V plusmn15 V

Frequency range 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz

OutputRated output voltage 2x115 Vac 2x24 Vac 2x12 Vac 2x115 Vac 2x115 Vac 2x115 Vac

Rated power VDE (DB cos phi=1) 800 VA 1000 VA 1000 VA 1000 VA 1600 VA 2000 VA

Rated power VDE (KB cos phi=05) 3400 VA 5000 VA 5000 VA 5000 VA 7800 VA 10900 VA

No-load voltage (app x factor) 103 103 103 103 101 102

Efficiency 94 94 94 94 94 94

StandardsClassification Control- and isolating

transformerControl- and isolatingtransformer

Control- and safety isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

Control- and isolatingtransformer

ApprovalsApprovals cURus cURus cURus cURus cURus cURus

EnvironmentAmbient temperature max 40 degC 40 degC 40 degC 40 degC 40 degC 40 degC

Cooling method self-cooling self-cooling self-cooling self-cooling self-cooling self-cooling

Safety and protectionType Open type Open type Open type Open type Open type Open type

Class of Insulation System VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130 VDE=B UL=class 130

Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00

Safety class (prepared) I I I I I I

Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 250 - 400 A 400 - 630 A 400 - 630 A 400 - 630 A 630 - 1000 A 800 - 1000 A

Setting value 230 plusmn15 Vac 370 A 460 A 460 A 460 A 730 A 910 A

Setting range 400 plusmn15 Vac 160 - 250 A 250 - 400 A 250 - 400 A 250 - 400 A 400 - 630 A 400 - 630 A

Setting value 400 plusmn15 Vac 220 A 270 A 270 A 270 A 420 A 520 A

Order numbersOrder Number STEU 80023 STEU 100048 STEU 100024 STEU 100023 STEU 160023 STEU 200023

+-Transformers Control transformers1

BLOCKWebsite

36 Subject to change

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 250023

InputRated input voltage 230400 Vac

Tappings Input plusmn15 V

Frequency range 50 - 60 Hz

OutputRated output voltage 2x115 Vac

Rated power VDE (DB cos phi=1) 2500 VA

Rated power VDE (KB cos phi=05) 12400 VA

No-load voltage (app x factor) 102

Efficiency 94

StandardsClassification Control- and isolating

transformer

ApprovalsApprovals cURus

EnvironmentAmbient temperature max 40 degC

Cooling method self-cooling

Safety and protectionType Open type

Class of Insulation System VDE=B UL=class 130

Protection index IP 00

Safety class (prepared) I

Short circuit strength non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 1000 - 1600 A

Setting value 230 plusmn15 Vac 1120 A

Setting range 400 plusmn15 Vac 630 - 1000 A

Setting value 400 plusmn15 Vac 650 A

Order numbersOrder Number STEU 250023

+-Transformers Control transformers1

Control- and safety isolating- resp isolatingtransformerSTEU

Typ

Term

inals

Fixing

met

hod

Fixing

scr

ews

Weig

ht

Dim

ensio

n pic

ture

(in

mm

)

A B C D E F

STEU 6348 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6324 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6323 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 10048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 16048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 25048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 25024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 102 104 84 87 625

STEU 25023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 32048 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32024 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32023 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 40024 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 40023 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 50048 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50024 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50023 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 63024 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 113 143 122 91 59STEU 63023 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 117 148 122 91 59STEU 80048 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80024 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80023 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 100048 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 100024 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 180 185 122 134 82STEU 100023 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 160023 Spring terminal PE 63 x 08 Base plate M8 2100 kg 2 192 161 185 155 133 80STEU 200023 Spring terminal PE 63 x 08 Base plate M8 2550 kg 2 192 183 185 156 155 91STEU 250023 Spring terminal PE 63 x 08 Base plate M8 2700 kg 2 192 190 185 156 161 94

30

Dimension pictures

BLOCKWebsite

11

12

51

13

21

22

31

32

33

52

40

Subject to change 37

Control- and safety isolating- resp isolatingtransformerSTEU

Typ

Term

inals

Fixing

met

hod

Fixing

scr

ews

Weig

ht

Dim

ensio

n pic

ture

(in

mm

)

A B C D E F

STEU 6348 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6324 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6323 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 10048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 16048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 25048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 25024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 102 104 84 87 625

STEU 25023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 32048 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32024 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32023 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 40024 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 40023 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 50048 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50024 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50023 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 63024 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 113 143 122 91 59STEU 63023 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 117 148 122 91 59STEU 80048 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80024 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80023 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 100048 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 100024 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 180 185 122 134 82STEU 100023 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 160023 Spring terminal PE 63 x 08 Base plate M8 2100 kg 2 192 161 185 155 133 80STEU 200023 Spring terminal PE 63 x 08 Base plate M8 2550 kg 2 192 183 185 156 155 91STEU 250023 Spring terminal PE 63 x 08 Base plate M8 2700 kg 2 192 190 185 156 161 94

30

Dimension pictures

Transformers Control transformers1

BLOCKWebsite

Page 7: 1 Control transformers Transformers · 2019. 10. 12. · to: VDE 0570 Part2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4, UL 5085-1/-2, CSA 22.2 No.66 UL 5085-1/-2, CSA 22.2 No.66

36 Subject to change

Control- and safety isolating- resp isolatingtransformerSTEU

Typ STEU 250023

InputRated input voltage 230400 Vac

Tappings Input plusmn15 V

Frequency range 50 - 60 Hz

OutputRated output voltage 2x115 Vac

Rated power VDE (DB cos phi=1) 2500 VA

Rated power VDE (KB cos phi=05) 12400 VA

No-load voltage (app x factor) 102

Efficiency 94

StandardsClassification Control- and isolating

transformer

ApprovalsApprovals cURus

EnvironmentAmbient temperature max 40 degC

Cooling method self-cooling

Safety and protectionType Open type

Class of Insulation System VDE=B UL=class 130

Protection index IP 00

Safety class (prepared) I

Short circuit strength non-short-circuit proof

PRI Fusing recommendationby circuit breaker withtripping characteristic type20 x Irated related to set)Setting range 230 plusmn15 Vac 1000 - 1600 A

Setting value 230 plusmn15 Vac 1120 A

Setting range 400 plusmn15 Vac 630 - 1000 A

Setting value 400 plusmn15 Vac 650 A

Order numbersOrder Number STEU 250023

+-Transformers Control transformers1

Control- and safety isolating- resp isolatingtransformerSTEU

Typ

Term

inals

Fixing

met

hod

Fixing

scr

ews

Weig

ht

Dim

ensio

n pic

ture

(in

mm

)

A B C D E F

STEU 6348 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6324 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6323 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 10048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 16048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 25048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 25024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 102 104 84 87 625

STEU 25023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 32048 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32024 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32023 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 40024 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 40023 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 50048 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50024 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50023 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 63024 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 113 143 122 91 59STEU 63023 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 117 148 122 91 59STEU 80048 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80024 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80023 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 100048 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 100024 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 180 185 122 134 82STEU 100023 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 160023 Spring terminal PE 63 x 08 Base plate M8 2100 kg 2 192 161 185 155 133 80STEU 200023 Spring terminal PE 63 x 08 Base plate M8 2550 kg 2 192 183 185 156 155 91STEU 250023 Spring terminal PE 63 x 08 Base plate M8 2700 kg 2 192 190 185 156 161 94

30

Dimension pictures

BLOCKWebsite

11

12

51

13

21

22

31

32

33

52

40

Subject to change 37

Control- and safety isolating- resp isolatingtransformerSTEU

Typ

Term

inals

Fixing

met

hod

Fixing

scr

ews

Weig

ht

Dim

ensio

n pic

ture

(in

mm

)

A B C D E F

STEU 6348 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6324 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6323 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 10048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 16048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 25048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 25024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 102 104 84 87 625

STEU 25023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 32048 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32024 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32023 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 40024 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 40023 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 50048 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50024 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50023 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 63024 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 113 143 122 91 59STEU 63023 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 117 148 122 91 59STEU 80048 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80024 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80023 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 100048 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 100024 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 180 185 122 134 82STEU 100023 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 160023 Spring terminal PE 63 x 08 Base plate M8 2100 kg 2 192 161 185 155 133 80STEU 200023 Spring terminal PE 63 x 08 Base plate M8 2550 kg 2 192 183 185 156 155 91STEU 250023 Spring terminal PE 63 x 08 Base plate M8 2700 kg 2 192 190 185 156 161 94

30

Dimension pictures

Transformers Control transformers1

BLOCKWebsite

Page 8: 1 Control transformers Transformers · 2019. 10. 12. · to: VDE 0570 Part2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4, UL 5085-1/-2, CSA 22.2 No.66 UL 5085-1/-2, CSA 22.2 No.66

11

12

51

13

21

22

31

32

33

52

40

Subject to change 37

Control- and safety isolating- resp isolatingtransformerSTEU

Typ

Term

inals

Fixing

met

hod

Fixing

scr

ews

Weig

ht

Dim

ensio

n pic

ture

(in

mm

)

A B C D E F

STEU 6348 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6324 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 6323 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 130 kg 1 84 85 88 64 64 46

STEU 10048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 10023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M4 210 kg 1 84 85 96 64 64 545

STEU 16048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 16023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 290 kg 1 96 102 104 84 87 56

STEU 25048 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 25024 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 102 104 84 87 625

STEU 25023 Spring terminal PE 63 x 08 Dual purpose base plate also forinstallation on mounting rails M5 360 kg 1 96 125 105 84 87 625

STEU 32048 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32024 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 32023 Spring terminal PE 63 x 08 Base plate M5 430 kg 2 120 107 121 90 74 55STEU 40024 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 40023 Spring terminal PE 63 x 08 Base plate M5 530 kg 2 120 104 121 90 86 60STEU 50048 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50024 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 50023 Spring terminal PE 63 x 08 Base plate M5 770 kg 2 120 124 121 90 106 71STEU 63024 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 113 143 122 91 59STEU 63023 Spring terminal PE 63 x 08 Base plate M6 790 kg 2 150 117 148 122 91 59STEU 80048 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80024 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 80023 Spring terminal PE 63 x 08 Base plate M6 1030 kg 2 150 130 143 122 1075 65STEU 100048 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 100024 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 180 185 122 134 82STEU 100023 Spring terminal PE 63 x 08 Base plate M6 1330 kg 2 150 156 143 122 134 82STEU 160023 Spring terminal PE 63 x 08 Base plate M8 2100 kg 2 192 161 185 155 133 80STEU 200023 Spring terminal PE 63 x 08 Base plate M8 2550 kg 2 192 183 185 156 155 91STEU 250023 Spring terminal PE 63 x 08 Base plate M8 2700 kg 2 192 190 185 156 161 94

30

Dimension pictures

Transformers Control transformers1

BLOCKWebsite