2-bcrra2013 ws frost-ulring alaskan design

22
Joel D. Ulring, P.E. Golder Associated Inc. Anchorage, Alaska USA June 24, 2013 BCRRA Conference Trondheim, Norway June 25-27, 2013 WORK SHOP 1 - PAVEMENT DESIGN IN COLD REGIONS

Upload: others

Post on 09-Jun-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 2-BCRRA2013 WS Frost-Ulring Alaskan design

Joel D. Ulring, P.E.Golder Associated Inc.

Anchorage, Alaska USAJune 24, 2013

BCRRA ConferenceTrondheim, Norway

June 25-27, 2013

WORK SHOP 1 - PAVEMENT DESIGN IN COLD REGIONS

Page 2: 2-BCRRA2013 WS Frost-Ulring Alaskan design

ORDER OF PRESENTATION

Introduction

Anchorage Facts

Municipality of Anchorage Pavement Design

Practice

State of Alaska Pavement Design Practice

Summary

July 2, 2013 2

Page 3: 2-BCRRA2013 WS Frost-Ulring Alaskan design

INTRODUCTION

July 2, 2013 3

Joel D. Ulring P.E.Senior Geotechnical Engineer

Golder Associates Inc.Anchorage Alaska

18 Years Public Service in Minnesota Counties

10 Years as Geotechnical Engineer Consultant

Page 4: 2-BCRRA2013 WS Frost-Ulring Alaskan design

ANCHORAGE FACTS

July 2, 2013 4

Page 5: 2-BCRRA2013 WS Frost-Ulring Alaskan design

AnchorageArea Map Population

- Alaska 790,000 - Anchorage 300,000

Significant Growth in 1970’s

ANCHORAGE FACTS

July 2, 2013 5

Page 6: 2-BCRRA2013 WS Frost-Ulring Alaskan design

ANCHORAGE FACTS

Anchorage Facts 61° North Latitude Design Thawing Index

Air = 4000 °DaysSurface = 3200 °Days

Design Freezing IndexAir = 3200 °DaysSurface = 6800 °Days

Typical Frost PenetrationDepth 9 feet (2.75 m)

July 2, 2013 6

Page 7: 2-BCRRA2013 WS Frost-Ulring Alaskan design

ANCHORAGE PAVEMENT DESIGN

July 2, 2013 7

Municipality of

Anchorage Pavement

Design

Page 8: 2-BCRRA2013 WS Frost-Ulring Alaskan design

ANCHORAGE PAVEMENT DESIGN

MOA Design Criteria Manual – Chapter 1 Streets Section 1.10 Road Structural Fill Design

Primary Design Objectives

Reduce freezing and thawing impacts on road

Obtain roadway/Pavement design life

July 2, 2013 8

Page 9: 2-BCRRA2013 WS Frost-Ulring Alaskan design

ANCHORAGE PAVEMENT DESIGN

MOA Design Criteria Manual – Chapter 1 Streets Section 1.10 Road Structural Fill Design

Mandatory Design Objectives

Mitigate the formation of ice lenses

Prevent pumping of subgrade

Prevent differential frost heave

July 2, 2013 9

Page 10: 2-BCRRA2013 WS Frost-Ulring Alaskan design

ANCHORGAE PAVEMENT DESIGN

July 2, 2013 10

Differential FrostHeaving of InsulatedPavement Section

Page 11: 2-BCRRA2013 WS Frost-Ulring Alaskan design

ANCHORAGE PAVEMENT DESIGN

PAVEMENT DESIGN PROCESS Subsurface Soil Investigation (1 borehole ≈ 300 ft.)

Laboratory Testing of Collected Soil Samples

Soil Frost Group Index DeterminedFrost Group: NFS, F1, F2, F3, F4

Thermal Analysis (Berg2)

Design Pavement Section

July 2, 2013 11

Page 12: 2-BCRRA2013 WS Frost-Ulring Alaskan design

ANCHORAGE PAVEMENT DESIGN

July 2, 2013 12

MOA Frost GroupSoil Classification

Page 13: 2-BCRRA2013 WS Frost-Ulring Alaskan design

ANCHORAGE PAVEMENT DESIGN

Typical Soil Typesof

Anchorage

July 2, 2013 13

Page 14: 2-BCRRA2013 WS Frost-Ulring Alaskan design

ANCHORAGE PAVEMENT DESIGN

MOA Design Criteria Manual – Chapter 1 Streets Section 1.10 Road Structural Design Methods

Minimum Section Complete Protection Method

Excavate and replace frost susceptible soils with non frost susceptible soil (NFS)

Limited Subgrade Frost Penetration Method Allows frost penetration of 10% into subgrade based on

thickness of structural section

Provision for use of rigid board insulation to reduce structural section thickness.

July 2, 2013 14

Page 15: 2-BCRRA2013 WS Frost-Ulring Alaskan design

ANCHORAGE PAVEMENT DESIGN

July 2, 2013 15

Minimum Structural SectionNFS Soil Subgrade

2” AC

2” Leveling Course

6” Type II-a Fill

12” Type II Fill

Subgrade(F1 Soils)

Page 16: 2-BCRRA2013 WS Frost-Ulring Alaskan design

ANCHORAGE PAVEMENT DESIGN

Complete Protection MethodTypical Pavement Structural Section

2” AC

2” Leveling Course

18” Type II-a Fill

2” Board Insulation

Type II Fill 24”- 30”

Calculated Frost DepthSubgrade(F2, F3 or F4 Soils)

July 2, 2013 16

Page 17: 2-BCRRA2013 WS Frost-Ulring Alaskan design

ANCHORAGE PAVEMENT DESIGN

Limited Subgrade Frost Penetration MethodTypical Pavement Structural Section

2” AC

2” Leveling Course

18” Type II-a Fill

2” Board Insulation

Type II Fill 18”- 26”

10% Frost Penetration

Calculated Frost DepthSubgrade(F2, F3 or F4 Soils)

July 2, 2013 17

Page 18: 2-BCRRA2013 WS Frost-Ulring Alaskan design

ANCHORAGE PAVEMENT DESIGN

TYPICAL STREET DESIGN SECTIONLimited Subgrade Frost Penetration Method

July 2, 2013 18

Page 19: 2-BCRRA2013 WS Frost-Ulring Alaskan design

ANCHORAGE PAVEMENT DESIGN

July 2, 2013 19

LEVELING COURSE GRADATION

Page 20: 2-BCRRA2013 WS Frost-Ulring Alaskan design

ANCHORAGE PAVEMENT DESIGN

Type IIU.S. Std. SieveCumulative %

Passing by Weight8“ 1003“ 70-100

1-1/2“ 55-1003/4“ 45-85#4 20-60

#10 12-50#40 4-30#200 2-6

July 2, 2013 20

Type II-aU.S. Std. SieveCumulative %

Passing by Weight3“ 1003/4“ 50-100#4 25-60#10 15-50#40 4-30#200 2-6

CLASSIFIED FILL GRADATIONS

Page 21: 2-BCRRA2013 WS Frost-Ulring Alaskan design

ANCHORAGE PAVEMENT DESIGN

COMMENTS How should current climate trends be accounted for in

design?

Should design parameters (Freezing & Thawing Indices) within Berg2 analysis be adjusted?

Should another thermal analysis model be considered?

MOA is currently reviewing their pavement design manual.

July 2, 2013 21

Page 22: 2-BCRRA2013 WS Frost-Ulring Alaskan design

THANK YOU !QUESTIONS ?