353 christian street trinity erd oxford, ct06478

63
TRINITY ERD EVALUATION REPORT CertainTeed Corporation 20 Moores Road Malvern, PA 19355 (610) 651-5847 Scope: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. Description: Flintlastic® Modified Bitumen Roof Systems Labeling: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. Continued Compliance: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity| ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. Advertisement: The Evaluation Report number preceded by the words 'Trinity | ERD Evaluated" may be displayed in advertising literature. Ifany portion of the Evaluation Report is displayed, then it shall be done in its entirety. Inspection: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6, plus a 57-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 . -„-i•„•>.• Certification of Independence: 1. Exterior Research & Design, LLC. d/b/a Trinity | ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity | ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity| ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. "v<i '2 Of.fi!. EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 Christian Street Oxford, CT 06478 (203) 262-9245 Evaluation Report 3520.03.04-R20 FL2533-R19 Date of Issuance: 09/19/2005 Revision 20:09/14/2017 The facsimile seal appearing was authorized by Robert Nieminen, P.E.on 09/14/2017. This does not serve as an electronically signed document.

Upload: others

Post on 31-Jan-2022

5 views

Category:

Documents


0 download

TRANSCRIPT

TRINITY ERD

EVALUATION REPORT

CertainTeed Corporation20 Moores Road

Malvern, PA 19355

(610) 651-5847

Scope:

This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use ofconstruction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated forcompliance with the 6th Edition (2017) Florida Building Code sections noted herein.

Description: Flintlastic® Modified Bitumen Roof Systems

Labeling: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency notedherein.

Continued Compliance: This Evaluation Report is valid until such time as the named product(s) changes, the referencedQuality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance ofthis Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the productchanges or the referenced Quality Assurance documentation changes. Trinity | ERD requires a complete review of thisEvaluation Report relative to updated Code requirements with each Code Cycle.

Advertisement: The Evaluation Report number preceded by the words 'Trinity | ERD Evaluated" may be displayed inadvertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.

Inspection: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer orits distributors and shall be available for inspection at the job site at the request of the Building Official.

This Evaluation Report consists of pages 1 through 6, plus a 57-page Appendix.

Prepared by:

Robert J.M. Nieminen, P.E.Florida Registration No. 59166, Florida DCA ANE1983 . -„-i•„•>.•

Certification of Independence:

1. Exterior Research & Design, LLC. d/b/a Trinity | ERD does not have, nor does it intend to acquire or will it acquire, a financial interestin any company manufacturing or distributing products it evaluates.

2. Exterior Research & Design, LLC. d/b/a Trinity | ERD is not owned, operated or controlled by any company manufacturing ordistributing products it evaluates.

3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products forwhich the evaluation reports are being issued.

4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of theproduct.

5. This is a building code evaluation. Neither Trinity| ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for anyproject on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retainedspecifically for that purpose.

"v<i

'2 Of.fi!.

EXTERIOR RESEARCH & DESIGN, LLC.Certificate ofAuthorization #9503

353 Christian Street

Oxford, CT 06478

(203) 262-9245

Evaluation Report 3520.03.04-R20FL2533-R19

Date of Issuance: 09/19/2005Revision 20:09/14/2017

The facsimile seal appearing was authorized by Robert Nieminen,

P.E.on 09/14/2017. This does not serve as an electronically signeddocument.

TRINITY ERD

Roofing Systems Evaluation:

Scope:

Product Category: RoofingSub-Category: Modified Bitumen Roof SystemsCompliance Statement: Flintlastic0 Modified Bitumen Roof Systems, as produced by CertainTeed Corporation,have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code throughtesting in accordance with the following Standards. Compliance is subject to the Installation Requirements andLimitations / Conditions of Use set forth herein.

Standards:

Section

1504.3.1

1504.7

1507.11.2

1507.11.2

1507.11.2

1507.11.2

1507.11.2

References:

Entity

ERD (TST6049)

ERD (TST6049)

ERD(TST6049)

ERD (TST6049)

ERD (TST6049)

ERD(TST6049)ERD (TST6049)

ERD (TST6049)

ERD (TST6049)

ERD (TST6049)ERD(TST6049)

ERD (TST6049)

ERD (TST6049)

ERD (TST6049)

ERD (TST6049)

ERD (TST6049)ERD (TST6049)

ERD (TST6049)

ERD (TST6049)ERD (TST6049)

ERD (TST6049)

ERD (TST6049)ERD (TST6049)

ERD(TST6049)

ERD (TST6049)

ERD (TST6049)ERD (TST6049)ERD(TST6049)

ERD (TST6049)

ERD (TST6049)

ERD (TST6049)ERD (TST6049)

ERD (TST6049)

ERD (TST6049)ERD (TST6049)

ERD (TST6049)

ERD (TST6049)

ERD (TST6049)

Exterior Research and Design, LLC.Certificate ofAuthorization U9S03

Property

Wind

Impact

Physical PropertiesPhysical PropertiesPhysical PropertiesPhysical PropertiesPhysical Properties

Examination

FM 4470

FM 4470

FM 4470

FM 4470

FM 4470/4474

FM 4470/4474FM 4470/4474

FM 4470/4474Physical PropertiesFM 4470/4474FM 4470/4474FM 4470/4474Physical PropertiesPhysical PropertiesFM 4470/4474FM 4470/4474

FM 4470/4474FM 4470/4474FM 4470/4474

FM 4470/4474

FM 4470/4474TAS117(B), RuptureFM 4470/4474

FM 4470/4474Physical PropertiesFM 4470/4474FM 4470/4474TAS 117(A)

FM 4470/4474

FM 4470/4474FM 4470/4474

FM 4470/4474FM 4470/4474

FM 4470/4474FM 4470/4474

FM4470

FM 4470/4474FM 4470/4474

Standard

FM 4474

FM 4470

ASTM D6162

ASTM D6163

ASTM D6164

ASTM D6222

ASTM D6509

Reference

3S04.06.01-1

3513.08.02

03515.07.03

3519.12.03

3522.07.04

02843.02.05-11

3533.01.06

4674.11.01-1

3535.10.06

3521.07.04-R1

02764.09.05-R1

02762.03.0S-R1

C7290.01.08

C10080.09.08

C8370.08.08-R1

P6860.06.07-R1

C30310.12.09

C30560.03.10

C31420.08.10

C33980.12.10

C33830.02.ll

C35500.02.ll

C37820.07.12

C37830.07.12

C42110.08.12

C39670.08.12

C42280.08.12

A35880.04.12-R1

C44580.07.13

C46090.ll.13-A

C45620.03.14

C46760.06.14

C47320.03.14-R1

CTR-SC899S.10.15

CTR-SC9935.01.16

CTR-SC9920.01.16-R1

CTR-SC10420.01.16

CTR-SC9175.09.16-1

6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic*Modified Bitumen RoofSystems; (610) 651-5847

Year

2011

2012

2008

2008

2011

2011

2009

Date

06/05/200108/15/2002

07/22/200312/22/200307/28/2004

02/10/200501/06/2006

03/21/200610/31/2006

10/26/200712/10/200712/10/2007

01/16/200809/04/200810/05/2009

09/10/2009

12/17/200903/18/2010

09/21/2010

12/22/2010

02/08/201102/09/2011

07/24/201207/26/201208/13/2012

08/20/2012

08/20/201210/26/2012

07/25/201311/20/201303/27/201406/19/201404/01/201510/14/201501/14/201601/20/2016

01/25/201609/06/2016

Evaluation Report 3520.03.04-R20FL2533-R19

Revision 20:09/14/2017Page 2 of 6

Entity

ERD(TST6049)ERD (TST6049)ERD (TST6049)ERD (TST6049)

FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)FM Approvals (TST1867)MTI (TST2508)

MTI (TST2508)MTI (TST2508)MTI (TST2508)MTI (TST2508)MTI (TST2508)MTI (TST2508)PRI (TST5878)PRI(TST5878)PRI (TST5878)PRI (TST5878)PRI (TST5878)PRI (TST5878)PRI (TST5878)PRI (TST5878)PRI (TST5878)PRI (TST5878)PRI (TST5878)UL, LLC. (QUA9625)

Exterior Research and Design, LLC.Certificate ofAuthorization #9503

Examination

FM 4470/4474

FM 4470/4474FM 4470/4474FM 4474

FM 4470

FM 4470

FM 4470

FM 4470

FM 4470

FM 4470

FM 4470

FM 4470

FM 4470

FM 4470

FM 4470

FM 4470

FM 4470

FM 4470

FM 4470

FM 4470

FM 4470

FM 4470

FM 4470/4474FM 4470/4474

FM 4470/4474FM 4470/4474FM 4470/4474

FM 4470/4474FM 4470/4474FM 4470/4474FM 4470/4474FM 4470/4474

FM 4470/4474FM 4470/4474FM 4470/4474FM 4470/4474FM 4470/4474FM 4470/4474Physical propertiesPhysical propertiesPhysical propertiesPhysical propertiesPhysical propertiesPhysical propertiesPhysical propertiesPhysical PropertiesPhysical PropertiesPhysical PropertiesPhysical PropertiesPhysical Properties

Physical PropertiesPhysical PropertiesPhysical PropertiesPhysical PropertiesPhysical PropertiesPhysical Properties

Quality Assurance

Reference

CTR-SC9175.09.16-1

CTR-SC11590.08.16-R1

CTR-SC12255.12.16

CRT-SC15775.17

0E3A2.AM

3W0A4.AM

3W0A2.AM

3W0A3.AM

1Z4A6.AM

3Y8A1.AM

2D5A9.AM

3009502

3008869

3009610

3006025

3012321

3009814

3014502

3015444

3014692

3014751

3018579

3020703

3021759

3022038

3023458

3026128

3024311

3025766

3028410

3026964

3031262

3031199

3032172

3037127

3039848

3046104

3048520

DX08C4A

DX20E3A

DX20E3A-001

AX31G8A

AX31G8D

AX31G8F

AX21G8C

CTC-032-02-01

CTC-034-02-01

CTC-066-02-01

CTC-067-02-01

CTC-068-02-01

CTC-070-02-01

CTC-071-02-01

CTC-093-02-01

CTC-116-02-01

CTC-183-02-01

CTC-259-02-01

Service Confirmation, R11656

6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

TRINITY ERD

Date

09/06/201609/06/201612/27/201609/13/201703/30/198203/16/199303/17/199303/17/199309/11/199609/30/199606/22/199912/12/200003/19/200110/15/200112/28/200107/29/200209/06/2002

04/04/200307/11/200308/05/200308/27/200310/09/200307/30/200406/03/200504/05/200607/18/200608/04/200611/01/200611/13/200602/19/200707/25/200711/30/200712/23/200806/12/200901/11/201012/02/201108/13/201309/19/201303/22/200403/22/200401/04/200608/21/200809/05/2008

06/05/200901/28/201101/16/200811/24/200808/08/201108/08/201108/08/201108/08/201108/08/201108/08/201104/03/2012

10/04/201312/11/2015Exp. 03/09/2020

Evaluation Report 3520.03.04-R20

FL2533-R19

Revision 20:09/14/2017Page 3 of 6

TRINITY ERD

Product Description:

This Evaluation Report covers Flintlastic® Modified Bitumen RoofSystems installed in accordance with CertainTeedCorporation published installation instructions and the Limitations / Conditions of Use herein. The followingCertainTeed products make up the subject systems.

Table 1: Roll-Goods for Flintlastic* Modified Bitumen Roof Systems

Type ProductSpecification

Reference Grade Type

Base Sheets

Flintlastic® SANailBase ASTM D4601 N/A II

Glasbase™ Base Sheet ASTM D4601 N/A II

All Weather/Empire™ Base ASTM D4601 N/A II

Flexiglas™ Base ASTM D4601 N/A II

Flintlastic™ Base 20 ASTM D4601 N/A II

Flintlastic Poly SMS Base Sheet ASTM D4601 N/A II

Yosemite® Venting Base ASTM D4897 N/A II

Ply SheetsFlintglas® Ply 4 ASTM D2178 N/A IV

Flintglas® Premium Ply 6 ASTM D2178 N/A VI

Base/Ply Membranes (APP)Flintlastic* APP Base T ASTM D6509 N/A N/AFlintlastic* STA ASTM D6222 S 1

Flintlastic* STA Plus ASTM D6222 S 1

Cap Membranes (APP)

Flintlastic* STA ASTM D6222 S 1

Flintlastic* STA Plus ASTM D6222 S 1

Flintlastic* GTA ASTM D6222 G 1

Flintlastic® GTA CoolStar™ ASTM D6222 G 1

Flintlastic* GTA-FR ASTM D6222 G 1

Flintlastic* GTA-FR CoolStar™ ASTM D6222 G 1

Base/Ply Membranes (SBS)

Flintlastic" SA PlyBase ASTM D1970 N/A N/ABlack Diamond® Base Sheet ASTM D1970 N/A N/AFlintlastic" SA Mid Ply ASTM D6163 S 1

Flintlastic* Ultra Glass SA ASTM D6163 S 1

Flintlastic* Base 20 ASTM D6163 S 1

Flintlastic" Base 20 T ASTM D6163 S 1

Flintlastic" Ultra Poly SMS Base Sheet ASTM D6164 S 1

Cap Membranes (SBS)

Flintlastic* FR Dual Cap ASTM D6162 G 1

Flintlastic" SA Cap FR ASTM D6163 G 1

Flintlastic" SA Cap FR CoolStar'" ASTM D6163 G 1

Flintlastic" Cap 30 ASTM D6163 G 1

Flintlastic" Cap 30 CoolStar™ ASTM D6163 G 1

Flintlastic" FR Cap 30 ASTM D6163 G 1

Flintlastic" FR Cap30 CoolStar™ ASTM D6163 G 1

Flintlastic" FR Cap 30T ASTM D6163 G 1

Flintlastic" FR Cap 30TCoolStar™ ASTM D6163 G 1

Flintlastic" SA Cap ASTM D6164 G 1

Flintlastic" SA Cap CoolStar™ ASTM D6164 G 1

Flintlastic" FR-P ASTM D6164 G 1

Flintlastic" FR-P CoolStar™ ASTM D6164 G 1

Flintlastic" GMS ASTM D6164 G 1

Flintlastic" GMS CoolStar™ ASTM D6164 G 1

Flintlastic" GTS ASTM D6164 G II

Flintlastic" GTS CoolStar™ ASTM D6164 G II

Flintlastic" GTS-FR ASTM D6164 G II

Flintlastic" GTS-FR CoolStar™ ASTM D6164 G II

Flintlastic" Premium FR-P ASTM D6164 G II

Flintlastic"Premium FR-P CoolStar™ ASTM D6164 G II

Exterior Research and Design, LLC.Certificate ofAuthorization #9503 6™ EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen RoofSystems; (610)651-5847

Evaluation Report 3520.03.04-R20FL2533-R19

Revision 20:09/14/2017

Page 4 of 6

TRINITY ERD

LIMITATIONS:

5.1 This is a building code evaluation. Neither Trinity | ERD nor Robert Nieminen, P.E. are, in any way, theDesigner of Record for any project on which this Evaluation Report, or previous versions thereof, is/was usedfor permitting or design guidance unless retained specifically for that purpose.

5.2 This Evaluation Report is not for use in HVHZjurisdictions.

5.3 Refer to a current UL Roofing Materials Directory for fire ratings of this product.

5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordancewith FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply.

5.5 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structuralmembers shall be in accordance with FBC requirements to the satisfaction of the Authority HavingJurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBCApproval documentation.

5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511.

5.7 For mechanically attached insulation or membrane or strip-bonded insulation, the maximum design pressurefor the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance withFBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified designprofessional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM LossPrevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM LossPrevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.

5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selectedassembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. Norational analysis is permitted for these systems.

5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in theexisting deck for withdrawal resistance. A qualified design professional shall review the data for comparisonto the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRIFX-1 or Testing Application Standard TAS 105.

5.10 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, theexisting deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. Ifany surface conditions exist that bring system performance into question, field uplift testing in accordancewith ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS124 shall be conducted on mock-ups of the proposed new roof assembly.

5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roofsystem shall be capable of resisting project design pressures on its own merit to the satisfaction of theAuthority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FMLoss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.

5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance withFBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application StandardRAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or1609.3(3).

5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3.

Exterior Research and Design, LLC. Evaluation Report 3520.03.04-R20Certificate ofAuthorization #9503 6thEDITION (2017) FBC NON-HVHZ EVALUATION FL2533-R19

CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847 Revision 20:09/14/2017Page 5 of 6

TRINITY ERD

Installation:

6.1 Flintlastic® Modified Bitumen Roof Systems shall be installed in accordance with CertainTeed Corporationpublished installation instructions, subject to the Limitations / Conditions of Useherein.

6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = MaximumDesign Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflectsthe ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already beenapplied). Referto FBC 1609 for determination of design wind loads.

Building Permit Requirements:

As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation ofthis product.

Manufacturing Plants:

Contact the named QA entityfor manufacturing facilities covered byF.A.C. Rule 61G20-3 QA requirements.

Quality Assurance Entity:

UL, LLC. - QUA9625; (414) 248-6409, [email protected]

- THE57-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT -

Exterior Research and Design, LLC. Evaluation Report 3520.03.04-R20Certificate ofAuthorization #9503 6™ EDITION (2017) FBC NON-HVHZ EVALUATION FL2533-R19

CertainTeed Flintlastic* Modified BitumenRoofSystems;(610) 651-5847 Revision 20:09/14/2017Page 6 of 6

Appendix 1: Attachment Requirements for Wind Upuft Resistance

Table Deck Application

1A Wood New or Reroof (Tear-Off)

IB Wood New, Reroof (Tear-Off) or Recover

1C Wood New, Reroof (Tear-Off) or Recover

ID Wood New, Reroof (Tear-Off) or Recover

1E-1 Wood New, Reroof (Tear-Off)

1E-2 Wood New, Reroof (Tear-Off) or Recover

IF Wood New or Reroof (Tear-Off)

2A Steel or Structural Concrete New, Reroof (Tear-Off) or Recover

2B Steel or Structural Concrete New, Reroof (Tear-Off) or Recover

2C Steel or Structural Concrete New, Reroof (Tear-Off) or Recover

3A Concrete New or Reroof (Tear-Off)

3B Concrete New or Reroof (Tear-Off)

3C Concrete New or Reroof (Tear-Off)

4A LWIC New or Reroof (Tear-Off)

4B LWIC New or Reroof (Tear-Off)

4C LWIC New, Reroof (Tear-Off)

5A CWF New or Reroof (Tear-Off)

5B CWF New or Reroof (Tear-Off)

5C CWF New, Reroof (Tear-Off) or Recover

SD CWF New, Reroof (Tear-Off)

6A Gypsum Reroof (Tear-Off)

6B Gypsum Reroof (Tear-Off)

6C Gypsum Reroof (Tear-Off)

6D Gypsum Reroof (Tear-Off)

7A Various Recover

7B Various Recover

Type Description

A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover

Mech. Attached Base Insulation, Bonded Top Insulation, Bonded RoofCover

Mech. Attached Insulation, Bonded Roof Cover

Insulated, Mech. Attached Base Sheet, Bonded Roof Cover

Non-Insulated, Mech. Attached Base Sheet, Bonded RoofCoverNon-Insulated, Mech. Attached Base Sheet, Bonded RoofCover

Non-Insulated, Bonded Roof Cover

Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover

Mech. Attached Insulation, Bonded Roof Cover

Insulated, Mech. Attached Base Sheet, Bonded RoofCover

A-l Bonded Insulation, Bonded Roof Cover

A-3 BondedTemp Roof/Vapor Barrier, BondedInsulation,BondedRoofCoverNon-Insulated, Bonded Roof Cover

A-l Bonded Insulation, Bonded Roof Cover

A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover

Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover

A-l Bonded Insulation, Bonded Roof Cover

A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover

Mech. Attached Insulation, Bonded Roof Cover

Non-Insulated, Mech. Attached Base Sheet, Bonded RoofCover

A-l Bonded Insulation, Bonded Roof Cover

A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover

Mech. Attached Insulation, Bonded Roof Cover

Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover

A-l Bonded Insulation, Bonded Roof Cover

Non-Insulated, Bonded Roof Cover

TRINITY ERD

Page

5-6

8-9

10-12

13-15

16-17

17

18-20

21-25

26-28

29-36

36

37

38-39

40

41-44

45

46

46

47

48-49

50

51

51

52-57

57

The following notes apply to the systems outlined herein:

1. The roof system evaluation herein pertains toabove-deck roof components. Roof decks shall be in accordance with FBC requirements tothe satisfaction ofthe Authority Having Jurisdiction. Load resistance of theroof deck shall be documented through proper codified and/or FBC Approval documentation.

2. Unless otherwise noted,fastenersand stressplatesfor insulation attachmentshall be as follows. Fasteners shall be of sufficient length forthe following engagements:> Wood Deck: OMG #14 Roofgrip with Flat Bottom Plate (Accutrac), OMG HD with OMG 3in. Galvalume Steel Plate, Dekfast #14 with Hex Plate or3" Round Insulation Plate, Trufast HD with Trufast 3"

MetalInsulation Platesor FlintFast #14 Fastenerwith FlintFast 3" Insulation Plates. Minimum 0.75-inch plywood penetrationor minimum 1-inch woodplankembedment.> Steel Deck: OMG #12 or#14 Roofgrip with Recessed orFlat Bottom Plate (Accutrac), OMG #12 Standard orHD with OMG 3in. Galvalume Steel Plate, Dekfast #12 or#14 with Hex Plate or3"Round

Insulation Plate, Trufast DP or HD with Trufast 3" Metal Insulation Plates or FlintFast #12 or#14 Fastener with FlintFast 3" Insulation Plates. Minimum 0.75-inch steel penetration andengage the top flute of the steel deck.

> Structural Concrete: OMG #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG HD or CD-10 with OMG 3 in. Galvalume Steel Plate, Dekfast #14 or DekSpike with Hex Plate or 3" RoundInsulation Plate, Trufast HD or CF with Trufast 3"Metal Insulation Plates or FlintFast #14 Fastener with FlintFast 3"Insulation Plates. Minimum 1-inch embedment. Fasteners installedwith a pilot hole in accordance with the fastener manufacturer's published installation instructions.

Exterior Research and Design, LLC. d/b/a Trinity)ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic" Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20:09/14/2017Appendix 1, Page 1 of 57

TRINITY ERD3. Unless otherwise noted, insulation maybe anyone layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, GlasRoc Roof Board or gypsum-based roofboard that meetsthe QA requirements

of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.

4. Minimum 200 psi,minimum 2-inch thicklightweight insulating concrete may be substituted for, or installed beneath rigid insulation board for System Type D(mechanically attached base sheet, bonded roofcover),whereby the base sheet screws and platesare installed throughthe LWIC to engagethe structural steel or concretedeck. Thestructural deck shall be of equalor greaterconfiguration to the steel and concretedecklistings. Roof decks andstructural members shall be inaccordance with FBC requirements to the satisfaction ofthe Authority Having Jurisdiction. Load resistance ofthe roof deck shall bedocumented through propercodified and/or FBCApproval documentation.

5. Preliminary insulationattachment for SystemTypeD: Unless otherwise noted, refer to Section 2.2.10.1.3of FM Loss Prevention DataSheet 1-29 (January2016).

6. Unless otherwise noted, insulation adhesive application ratesare as follows. Ribbon or beadwidth isat the timeofapplication; the ribbons/beads shall expand as notedinthe manufacturer's published instructions.> Hot asphalt (HA): Fullcoverage at 25-30 lbs/square> Ashland Pliodeck (A-PD): Continuous 0.75inch wide ribbons, 12-inch o.c. Ribbons ofsubsequent layers shall beperpendicular tothose inthe layer below.> Dow INSTA-STIK Quik Set Insulation Adhesive (D-IS): Continuous 0.75 to 1 inch wide ribbons, 12-inch o.c.> Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.> Millennium PG-1Pump Grade Adhesive (M-PG1): Continuous 0.5 to 0.75-inch wide ribbons, 12-inch o.c.> OMG OlyBond 500 or OlyBond Green (OB500): Continuous 0.75-inch wide ribbons,12-incho.c. (PaceCart or SpotShot)> ICP Adhesives CR-20: Continuous 2.5 to 3-inch wide ribbons, 12-inch o.c.> Note: When multiple layers(s) of insulation and/orcoverboard areinstalled inribbon-applied adhesive, boards shallbestaggeredfromlayer-to-layer.> Note: The maximum edgedistancefromtheadhesive ribbon to theedgeof theinsulation board shallbenotless than one-half thespecified ribbons spacing.

7. Unless otherwise noted, allinsulations are flat-stock or taperboard ofthe minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may besubstituted with the following MaximumDesign Pressure (MDP) limitations. In nocase shall these values be used to 'increase' the MDP listings inthe tables; rather ifMDP listing below meets or exceeds that listed for a particular system in the tables, thenthe thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table:

> Ashland Pliodeck (A-PD) @ 12-inch o.c.> Ashland Pliodeck (A-PD) <S> 6-inch o.c.> Dow INSTA-STIK Quik Set Insulation Adhesive (D-IS):> Millennium One Step Foamable Adhesive (M-OSFA):> Millennium PG-1 Pump Grade Adhesive (M-PG1):> OMG OlyBond 500 (OB500):> OMG OlyBond 500 (OB500):> OMG OlyBond 500 (OB500):> OMG OlyBond 500 (OB500):> ICP Adhesives CR-20:

8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft.

9. For mechanically attachedcomponents or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined inaccordance with FBCChapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM LossPrevention Data Sheet 1-29 andRoofing Application Standard RAS 117. Assemblies marked with anasterisk* carry the limitations set forth inSection 2.2.10.1 ofFM Loss Prevention Data Sheet 1-29 (January 2016) forZone 2/3 enhancements.

10. For assemblies with all components fully bonded in place, the maximum design pressure for theselected assembly shall meet orexceed critical design pressure determined inaccordance with FBC Chapter 16, and norational analysis is permitted.

11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. Aqualified design professional shall review the data for comparison to theminimumrequirements for the system. Testingand analysisshall be in accordance with ANSI/SPRI FX-1 or TestingApplication Standard TAS 105.

Exterior Research andDesign, LLC. d/b/a Trinity | ERD Evaluation Report 3520.03.04-R20 forFL2533-R19Certificate ofAuthorization #9503 6™ EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/14/2017Prepared by: Robert Nieminen, PE-59166 CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-S847 Appendix 1,Page 2of57

MDP -105.0 psf (Min. 1.0-inch)MDP -277.5 psf (Min. 1.0-inch)MDP -120.0 psf (Min. 1.0-inch)MDP -157.5 psf (Min. 1.0-inch)MDP -157.5 psf (Min. 1.0-inch)MDP -45.0 psf (Min. 0.5-inch Multi-Max FA3)MDP -187.5 psf (Min. 0.5-inch ISO 95+ GL)MDP -315.0 psf (Min. 0.5-inch ENRGY 3)MDP -487.5 psf (Min. 0.5-inch ACFoam II)MDP -117.5 psf (Min. 1.0-inch)

TRINITY ERD12. For existing substrates in abonded recover or re-roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing

roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance withANSI/SPRI IA-l, ASTM E907, FM Loss Prevention DataSheet 1-52or Testing Application StandardTAS 124.

13. ForConcrete Deckor RecoverApplications usingSystemType D,the insulationis optional.

14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWCProduct Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top-coat thickness is 2-mches.For LWCover structural concrete, reference is made to FBCSection 1917.4.1, Point 1

15. Unlessotherwise noted, refer to the following references for bonded base, plyor cap sheet applications.

Reference

BP-AA

(Base and Plysheets, Asphatt-Apptied)

BP-AA2

(Base, Spot Asphalt-Applied)

BP-AA3

(Base, Spot-Asphatt-Applied)

BP-AA4

(Base, Strlp-AsphallApplied)

BP-CA2

BP-CA3

SBS-AA

(SBS, Asphalt-Applied)

SBS-CA1

(SBS, Cold-Applied)

SBS-CA2

(SBS, Cold-Applied)

Layer

Base

Ply

Base

Base

Base

Base/Ply

Base/Ply

Base

Ply

Cap

Base

Note:

Ply

Cap

Base

Ply

Cap

Exterior Research and Design, LLC. d/b/a Trinity IERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

CertainTeed Funtiastcc* Modified Bitumen Components & Appucation Methods

Material

Glasbase; All Weather/Empire Base; FlexiglasBase; Flintlastic Base 20

One or more Flintglas Ply4; Flintglas Premium Ply6

Yosemite Venting Base

Yosemite Venting Base

Yosemite Venting Base

Glasbase; All Weather/Empire Base; Flexiglas Base; FlintlasticBase 20

Glasbase; AllWeather/Empire Base; FlexiglasBase; Flintlastic Base 20

Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base

One or more Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base

Flintlastic Cap 30; Flintlastic Cap 30CoolStar; Flintlastic FR Cap 30; Flintlastic FR Cap 30CoolStar; Flintlastic FR DualCap; Flintlastic FR-P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar;FlintlasticGMS; FlintlasticGMS CoolStar

Flintlastic Base 20; Flintlastic PolySMS Base; Flintlastic Ultra PolySMS Base

Base ply cures overnight prior to application of the plyor cap ply.

Flintlastic Base 20; Flintlastic PolySMS Base; Flintlastic Ultra PolySMS Base

Flintlastic FR Cap 30;Flintlastic FR Cap 30CoolStar; Flintlastic FR Dual Cap; Flintlastic FR-P; Flintlastic FR-P CoolStar;Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS; Flintlastic GMS CoolStarFlintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base

Flintlastic Base 20; Flintlastic PolySMS Base; Flintlastic Ultra Poly SMS Base

Flintlastic Cap 30;Flintlastic Cap 30CoolStar; Flintlastic FR Cap 30;Flintlastic FR Cap 30CoolStar; Flintlastic FR DualCap; Flintlastic FR-P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar;FlintlasticGMS; FlintlasticGMSCoolStar _^__

Application

Hot asphalt at 20-40 lbs/square

Hot asphalt in 24-inch diameter spots in 30-inch grid pattern

Hot asphalt in 9-inch diameter spots in gridpattern noted herein.

Hot asphalt in 9-inch wide ribbons spacedas noted herein.

Henry#903 Adhesive at 1.5 gal/square

Millennium Hurricane Force Membrane

Adhesive, beads spaced 6-inch o.c.

Hot asphalt at 20-40 lbs/square

FlintBond Brush or Karnak No. 81 Cold

Process Modified Bitumen Adhesive Brush

Grade at 1 gal/square

Henry#903 Adhesive at 1.5 gal/square.

6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic" Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017Appendix 1, Page 3 of 57

TRINITY ERD

CertainTeed Funtiastic* Modified Bitumen Components & Application Methods (continued)

Reference Layer Material Application

SBS-CA3

(SBS, Cold-Applied)

Base Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base

Millennium Hurricane Force Membrane

Adhesive, beads spaced 6-inch o.c.

Ply Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base

Cap Flintlastic Cap 30; Flintlastic Cap 30 CoolStar; Flintlastic FRCap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR DualCap; Flintlastic FR-P; Flintlastic FR-PCoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-PCoolStar;Flintlastic GMS; Flintlastic GMS CoolStar

SBS-TA

(SBS, Torch-Applied)

Base Flintlastic Ultra Poly SMS Base; Flintlastic Base 20 T

Torch-AppliedPly One or more Flintlastic Ultra Poly SMS Base; Flintlastic Base 20 T

Cap Flintlastic FRCap 30 T; Flintlastic FRCap 30 T CoolStar; Flintlastic GTS; Flintlastic GTS CoolStar; Flintlastic GTS-FR;Flintlastic GTS-FRCoolStar; FlintClad

APP-TA

(APP, Torch-Applied)

Base One or more Flintlastic APP Base T; Flintlastic STA; Flintlastic STA Plus

Torch-AppliedCap Flintlastic STA; Flintlastic STA Plus; Flintlastic GTA; Flintlastic GTA CoolStar; Flintlastic GTA-FR; Flintlastic GTA-FRCoolStar

SBS-SA-H

(SBS, Self-Adhering. Hybrid Systems)

Base/Ply Black Diamond Base Sheet; Flintlastic Ultra Glass SASelf-Adhering

SBS-SA

(SBS, Self-Adhering)

Base Flintlastic SA PlyBase; Flintlastic SA Mid Ply

Self-AdheringPly Flintlastic SA PlyBase; Flintlastic SA Mid Ply

Cap Flintlastic SACap; Flintlastic SACap CoolStar; Flintlastic SACap FR;Flintlastic SACap FRCoolStar

16. "MDP" =Maximum Design Pressure is the resultof testingforwindload resistance based on allowable windloads.Refer to FBC 1609for determinationof design windloads.

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19

Revision 20: 09/14/2017Appendix 1, Page 4 of 57

TRINITY ERD

TABLE 1A: WOOD DECKS - NEW CONSTRUCTION or REROOF(Tear-Off)

SYSTEM TYPE A-2: MECHANICALLYATTACHEDANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER

Sys.

No.

Deck

(Note 1)

Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 14) MDP

(psf)Type Fasteners Attach Type Attach Type Attach Base Ply Cap

Self-Adhering Systems:

W-l

Min. 19/32-

inch

plywood atmax. 24-

inch spans

Glasbase, All

Weather Empire,

Flexiglas Base,Flintlastic Base 20;

Poly SMS; Ultra PolySMS; Yosemite

32 ga., 1-5/8-inch dia. tin

caps with 11 ga.

annular ring

shank nails

9-inch o.c. in 4-inch

lap and 12-inch o.c.in two (2), equallyspaced, staggeredcenter rows

Min. 1.5-inch

ACFoam II,

FlintBoard ISO,

ENRGY-3, H-Shield

or Multi-Max FA3

HA

Min. 0.25-inch

Dens Deck

primed withFlintPrime or

FlintPrime SA

HA SBS-SA(Optional)

SBS-SASBS-SA -45.0*

W-2

Min. 19/32-

inch

plywood at

max. 24-

inch spans

Glasbase, All

Weather Empire,

Flexiglas Base, PolySMS or Ultra Poly

SMS

32 ga., 1-5/8-inch dia. tin

caps with 11 ga.annular ringshank nails

8-inch o.c. in 3-inch

lap and 8-inch o.c.in three (3), equallyspaced, staggeredcenter rows

Min. 1.5-inch

ACFoam II,

FlintBoard ISO,

ENRGY-3, H-Shield

or Multi-Max FA3

HA full

coverage or

OB500, M-

OSFA, A-PD,

D-IS or CR-20,

4-inch o.c.

Min. 0.25-inch

Dens Deck

primed with

FlintPrime or

FlintPrime SA

HA full

coverage or

OB500, M-

OSFA, A-PD, D-

IS or CR-20, 6-

inch o.c.

SBS-SA(Optional)

SBS-SASBS-SA -52.5

W-3

Min. 19/32-

inch

plywood at

max. 24-

inch spans

Yosemite Venting

Base Sheet

32 ga., 1-5/8-inch dia. tin

caps with 11 ga.annular ring

shank nails

8-inch o.c. in 3-inch

lap and 8-inch o.c.in three (3), equallyspaced, staggered

center rows

Min. 1.5-inch

ACFoam II,

FlintBoard ISO,

ENRGY-3, H-Shield

or Multi-Max FA3

HA

Min. 0.25-inch

Dens Deck

primed with

FlintPrime or

FlintPrime SA

HA SBS-SA(Optional)SBS-SA

SBS-SA -52.5

W-4

Min. 19/32-inch

plywood atmax. 24-

inch spans

Glasbase, AllWeather Empire,

Flexiglas Base, PolySMS or Ultra Poly

SMS

32 ga., 1-5/8-inch dia. tin

caps with 11 ga.

annular ring

shank nails

8-inch o.c. in 3-inch

lap and 8-inch o.c.in three (3), equallyspaced, staggered

center rows

(Optional) Min.1.5-inch ACFoam

II, FlintBoard ISO,

ENRGY-3, H-Shield

or Multi-Max FA3

HA full

coverage or

OB500, M-

OSFA, A-PD,

D-IS or CR-20,

4-inch o.c.

Min. 0.25-inch

SECUROCK

Gypsum-FiberRoof Board

primed with

FlintPrime or

FlintPrime SA

HA full

coverage or

OB500, M-

OSFA, A-PD, D-

IS or CR-20, 6-

inch o.c.

SBS-SA(Optional)

SBS-SASBS-SA -60.0

W-5

Min. 19/32-

inch

plywood atmax. 24-

inch spans

Yosemite Venting

Base Sheet

32 ga., 1-5/8-inch dia. tin

caps with 11 ga.annular ring

shank nails

8-inch o.c. in 3-inch

lap and 8-inch o.c.in three (3), equallyspaced, staggeredcenter rows

(Optional) Min.1.5-inch ACFoam

II, FlintBoard ISO,

ENRGY-3, H-Shield

or Multi-Max FA3

HA

Min. 0.25-inch

SECUROCK

Gypsum-Fiber

Roof Board

primed withFlintPrime or

FlintPrime SA

HA SBS-SA(Optional)SBS-SA

SBS-SA -60.0

Hybrid Systems:

W-6

Min. 19/32-

inch

plywood atmax. 24-

inch spans

Glasbase, All

Weather Empire,

Flexiglas Base,Flintlastic Base 20;

Poly SMS; Ultra Poly

SMS; Yosemite

32 ga., 1-5/8-inch dia. tin

caps with 11 ga.

annular ring

shank nails

9-inch o.c. in 4-inch

lap and 12-inch o.c.in two (2), equallyspaced, staggeredcenter rows

Min. 1.5-inch

ACFoam II,

FlintBoard ISO,

ENRGY-3, H-Shield

or Multi-Max FA3

HA None N/A SBS-SA-H

(Optional)BP-AA, SBS-

AA, SBS-TA

orAPP-TA

SBS-AA,

SBS-TA

orAPP-

TA

-45.0*

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

6thEDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 5 of 57

TRINITY ERDTABLE 1A: WOOD DECKS - NEW CONSTRUCTION or REROOF (Tear-Off)

SYSTEMTYPEA-2: MECHANICALLY ATTACHED ANCHORSHEET, BONDED INSULATION, BONDED ROOF COVER

Sys.

No.

Deck

(Note 1)

Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 14) MDP

(psf)Type Fasteners Attach Type Attach Type Attach Base Ply Cap

W-7

Min. 19/32-inch

plywood atmax. 24-

inch

Glasbase; FlintglasPremium Ply 6;

Yosemite

32 ga., 1-5/8-inch dia. tin

caps with 11 ga.annular ringshank nails

8-inch o.c. in 3-inch

lap and 8-inch o.c.in three (3), equallyspaced, staggeredcenter rows

Min. 1.5-inch

ACFoam II,

FlintBoard ISO,ENRGY-3, H-Shield

or Multi-Max FA3

HA None N/A SBS-SA-H

(Optional)BP-AA, SBS-

AA, SBS-TA

or APP-TA

SBS-AA,

SBS-TA

or APP-

TA

-60.0

Conventional Systems:

W-8

Min. 19/32-

inch

plywood at

max. 24-

inch spans

Glasbase, All

Weather Empire,Flexiglas Base,Flintlastic Base 20;Poly SMS; Ultra PolySMS; Yosemite

32 ga., 1-5/8-inch dia. tin

caps with 11 ga.annular ringshank nails

9-inch o.c. in 4-inch

lap and 12-inch o.c.

in two (2), equallyspaced, staggeredcenter rows

Min. 1.5-inch

ACFoam II,

FlintBoard ISO,

ENRGY-3, H-Shield

or Multi-Max FA3

HA

Min. 0.25-inch

Dens Deck

primed withFlintPrime (ASTMD41) primer

HA

BP-AA,

SBS-AA,

SBS-TA or

APP-TA

(Optional)BP-AA, SBS-

AA, SBS-TA

or APP-TA

SBS-AA,

SBS-TA

or APP-

TA

-45.0*

W-9

Min. 19/32-

inch

plywood atmax. 24-

inch spans

Glasbase, All

Weather Empire,Flexiglas Base, PolySMS or Ultra Poly

SMS

32 ga., 1-5/8-inch dia. tin

caps with 11 ga.annular ringshank nails

8-inch o.c. in 3-inch

lap and 8-inch o.c.

in three (3), equallyspaced, staggeredcenter rows

Min. 1.5-inch

ACFoam II,

FlintBoard ISO,

ENRGY-3, H-Shield

or Multi-Max FA3

HA full

coverage or

OB500, M-

OSFA, A-PD,

D-IS or CR-20,

4-inch o.c.

Min. 0.25-inch

Dens Deck

primed withFlintPrime (ASTMD41) primer

HA full

coverage or

OB500, M-

OSFA, A-PD, D-IS or CR-20, 6-

inch o.c.

BP-AA,

SBS-AA,

SBS-TA or

APP-TA

(Optional)BP-AA, SBS-

AA, SBS-TA

or APP-TA

SBS-AA,

SBS-TA

or APP-

TA

-52.5

W-10

Min. 19/32-

inch

plywood atmax. 24-

inch spans

Yosemite VentingBase Sheet

32 ga., 1-5/8-inch dia. tin

caps with 11 ga.annular ringshank nails

8-inch o.c. in 3-inch

lap and 8-inch o.c.in three (3), equallyspaced, staggeredcenter rows

Min. 1.5-inch

ACFoam II,

FlintBoard ISO,

ENRGY-3, H-Shield

or Multi-Max FA3

HA

Min. 0.25-inch

Dens Deck

primed withFlintPrime (ASTMD41) primer

HA

BP-AA,

SBS-AA,

SBS-TA or

APP-TA

(Optional)BP-AA, SBS-

AA, SBS-TA

or APP-TA

SBS-AA,

SBS-TA

or APP-

TA

-52.5

W-ll

Min. 19/32-inch

plywood atmax. 24-

inch spans

Glasbase, All

Weather Empire,Flexiglas Base, PolySMS or Ultra PolySMS

32 ga., 1-5/8-inch dia. tin

caps with 11 ga.annular ringshank nails

8-inch o.c. in 3-inch

lap and 8-inch o.c.

in three (3), equallyspaced, staggeredcenter rows

(Optional) Min.1.5-inch ACFoam

II, FlintBoard ISO,ENRGY-3, H-Shield

or Multi-Max FA3

HA full

coverage or

OB500, M-

OSFA, A-PD,

D-IS or CR-20,

4-inch o.c.

Min. 0.25-inch

SECUROCK

Gypsum-FiberRoof Board

HA full

coverage or

OB500, M-

OSFA, A-PD, D-

IS or CR-20, 6-

inch o.c.

BP-AA,

SBS-AA,

SBS-TA or

APP-TA

(Optional)BP-AA, SBS-

AA, SBS-TA

or APP-TA

SBS-AA,

SBS-TA

or APP-

TA

-60.0

W-12

Min. 19/32-

inch

plywood at

max. 24-

inch spans

Yosemite Venting

Base Sheet

32 ga., 1-5/8-inch dia. tin

caps with 11 ga.annular ringshank nails

8-inch o.c. in 3-inch

lap and 8-inch o.c.

in three (3), equallyspaced, staggeredcenter rows

(Optional) Min.1.5-inch ACFoam

II, FlintBoard ISO,

ENRGY-3, H-Shieldor Multi-Max FA3

HA

Min. 0.25-inch

SECUROCK

Gypsum-FiberRoof Board

HA

BP-AA,

SBS-AA,

SBS-TA or

APP-TA

(Optional)BP-AA, SBS-

AA, SBS-TA

or APP-TA

SBS-AA,

SBS-TA

or APP-

TA

-60.0

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic*Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2S33-R19

Revision 20: 09/14/2017

Appendix 1, Page 6 of 57

TRINITY ERD

TABLE IB: WOOD DECKS - NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVERSYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDEDTOP INSULATION,BONDEDROOFCOVER

System

No.

Deck

(Note 1)

Base insulation Layer Top Insulation Layer Roof Cover (Note 14)MDP (psf)

Type Fasteners Attach Type Attach Base Ply Cap

Hybrid Systems: —_, ,

W-13

Min. 15/32-inchexterior gradeplywood at max. 24-inch spans

Min. 1.5-inch ACFoam

II, FlintBoard ISO, H-

Shield or FlintBoard

ISOH.

FlintFast #12 or

#14 with

FlintFast 3"

Insulation Plates

1 per 1.33

ft2

Min. 1.5-inch ACFoam II,

FlintBoard ISO, H-Shield or

FlintBoard ISOH.

HA, D-IS, M-

OSFA, M-PGl

or OB500

SBS-SA-H (Optional) APP-TA APP-TA -67.5

Conventional Systems: , ,

W-14

Min. 23/32-inchexterior grade

plywood at max. 24-

inch spans

Min. 1.5-inch ACFoam

II, FlintBoard ISO,

ENRGY3, H-Shield

Note 2 1 per 2 ft2

Min. 0.5-inch Structodek

High Density FiberboardRoof Insulation, min. 0.75-

inch FescoBoard

(homogeneous)

HABP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-45.0*

W-15

Min. 23/32-inchexterior gradeplywood at max. 24-inch spans

Min. 1.5-inch ACFoam

II, FlintBoard ISO,

ENRGY3, H-Shield

Note 2 1 per 2 ft2

Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof Board,Dens Deck or Dens Deck

Prime

HA

BP-AA, SBS-

AA, SBS-TA

or APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-45.0*

W-16

Min. 15/32-inch

exterior gradeplywood at max. 24-inch spans

Min. 1.5-inch ACFoam

II, FlintBoard ISO, H-Shield or FlintBoard

ISOH.

FlintFast #12 or

#14 with

FlintFast 3"

Insulation Plates

1 per 1.33ft2

Optional additional layer(s)of base insulation followed

by Min. 0.25-inch SECUROCKGypsum-Fiber Roof board

HA, D-IS, M-

OSFA, M-PGl

or OB500

APP-TA (Optional) APP-TA APP-TA -90.0

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 7 of 57

TRINITY ERDTABLE IC: WOOD DECKS - NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVERSYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOFCOVER

System

No.

Deck

(Note 1)Base Insulation Layer

Top Insulation Layer Roof Cover (Note 14) MDP

(psf)Type Fasteners Attach Base Ply CapSelf-Adhering Systems:

W-17

Min. 15/32-inchplywood at max. 24-inch spans

(Optional) One or more

layers, any combination,loose laid

Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof Board

Flintfast 3 in. Insulation

Plates with FlintFast #12

or #14

1 per 3.2 ft2 SBS-SA(Optional) SBS-SA

SBS-SA -30.0*

W-18

Min. 19/32-inch

exterior grade plywoodat max. 24-inch spans

(Optional) One or more

layers, any combination,loose laid

Min. 0.25-inch Dens Deck Note 2 1 per 1.33 ft2

Apply FlintPrime or

FlintPrime SA to

board & plates,

followed by SBS-SA

(Optional) SBS-SA

SBS-SA -45.0

W-19

Min. 19/32-inch

exterior grade plywoodat max. 24-inch spans

(Optional) One or more

layers, any combination,loose laid

Min. 3/8-inch SECUROCK

Gypsum-Fiber Roof Board

Flintfast 3 in. Insulation

Plates with FlintFast #12

or #14

1 per 2.7 ft2 SBS-SA(Optional) SBS-SA

SBS-SA -45.0*

W-20

Min. 19/32-inchplywood at max. 24-inch spans

(Optional) One or morelayers, any combination,loose laid

Min. 1.5-inch ACFoam II,

ENRGY3, H-Shield, Multi-MaxFA3 or FlintBoard ISO

Flintfast 3 in. Insulation

Plates with FlintFast #12

or #14

1 per 2 ft2

Apply FlintPrime orFlintPrime SA to

board & plates,

followed by SBS-SA

(Optional) SBS-SA

SBS-SA -45.0*

W-21

Min. 15/32-inch

plywood at max. 24-inch spans

(Optional) One or morelayers, any combination,loose laid

Min. 1.5-inch FlintBoard ISO

FlintFast #14 HD with

FlintFast 3" Insulation

Plates or Trufast HD

with Trufast 3" Metal

Insulation Plates

1 per 1.6 ft2Apply FlintPrime to

board & plates,followed by SBS-SA

(Optional) SBS-SA

SBS-SA -52.5

W-22

Min. 19/32-inchplywood at max. 24-inch spans

(Optional) One or morelayers, any combination,loose laid

Min. 1.5-inch ACFoam II,

ENRGY 3, H-Shield, Multi-Max

FA3 or FlintBoard ISO

Note 2 1 per 1.45 ft2

Apply FlintPrime or

FlintPrime SA to

board & plates,followed by SBS-SA

(Optional) SBS-SA

SBS-SA -60.0

Hybrid Systems:

W-23

Min. 15/32-inch

plywood at max. 24-

inch spans

(Optional) One or more

layers, any combination,loose laid

Min. 0.25-inch Dens Deck;

Dens Deck Prime

Flintfast 3 in. Insulation

Plates with FlintFast #12

or #14

1 per 2 ft2 SBS-SA-H

(Optional) BP-AA, SBS-AA, SBS-

TA or APP-TA

SBS-AA, SBS-TA

or APP-TA-30.0*

W-24

Min. 15/32-inchplywood at max. 24-inch spans

(Optional) One or morelayers, any combination,loose laid

Min. 1.5-inch FlintBoard ISO

FlintFast #14 HD with

FlintFast 3" Insulation

Plates or Trufast HD

with Trufast 3" Metal

Insulation Plates

1 per 1.6 ft2 SBS-SA-H(Optional) SBS-TA or APP-TA

SBS-TA or APP-

TA-52.5

W-25

Min. 15/32-inch

plywood at max. 24-

inch spans

(Optional) One or more

layers, any combination,loose laid

Min. 1.5-inch ACFoam II,

FlintBoard ISO, ENRGY3 or

Multi-Max FA3

Note 2 1 per 1.33 ft2 SBS-SA-H(Optional) BP-AAorSBS-AA

SBS-AA -52.5

W-26

Min. 19/32-inchplywood at max. 24-inch spans

(Optional) One or morelayers, any combination,loose laid

Min. 1.5-inch ACFoam II,

FlintBoard ISO, H-Shield,FlintBoard ISOH

Note 2 1 per 1.45ft2 SBS-SA-H

(Optional) BP-AA, SBS-AA, SBS-

TA or APP-TA

SBS-AA, SBS-TA

or APP-TA-60.0

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen RoofSystems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017Appendix 1, Page 8 of 57

TRINITY ERDTABLEIC: WOOD DECKS - NEW CONSTRUCTION, REROOF (Tear-Off) OR RECOVER

SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER

System

No.

Deck

(Note 1)Base Insulation Layer

Top Insulation Layer Roof Cover (Note 14) MDP

(psf)Type Fasteners Attach Base Ply Cap

W-27

Min. lS/32-inch

plywood at max. 24-inch spans

(Optional) Min. 1.5-inch, Oneor more layers, anycombination, loose laid

Min. 1.5-inch ACFoam II,

FlintBoard ISO, H-Shield,FlintBoard ISOH

Flintfast 3 in. Insulation

Plates with FlintFast #12

or #14

1 per1.33ft2 SBS-SA-H

(Optional) SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-TA

or APP-TA-75.0

W-28

Min. 19/32-inch

exterior grade plywoodat max. 24-inch spans

(Optional) One or morelayers, any combination,loose laid

Min. 1.5-inch ACFoam II,

FlintBoard ISO, ENRGY3 or

Multi-Max FA3

Note 2 1 per1.33ft2 SBS-SA-H(Optional) SBS-TA or APP-TA

SBS-TA or APP-

TA-82.5

Conventional Systems:

W-29

Min. 23/32-inchexterior grade plywoodat max. 24-inch spans

(Optional) One or morelayers, any combination,loose laid

Min. 0.5-inch Structodek HighDensity Fiberboard RoofInsulation, min. 0.75-inchFescoBoard (homogeneous)

Note 2 1 per 2 ft2 BP-AA or SBS-AA

(Optional) BP-AA, SBS-AA, SBS-

TA or APP-TA

SBS-AA, SBS-TA

or APP-TA-45.0*

W-30

Min. 15/32-inchplywood at max. 24-inch spans

(Optional) One or morelayers, any combination,loose laid

Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof Board,Dens Deck or Dens Deck

Prime

FlintFast #12 or #14 HD

with FlintFast 3"

Insulation Plates

1 per 2 ft2BP-AA, SBS-AA,

SBS-TA or APP-

TA

(Optional) BP-AA, SBS-AA, SBS-

TA or APP-TA

SBS-AA, SBS-TA

or APP-TA-45.0*

W-31

Min. 15/32-inch

plywood at max. 24-inch spans

(Optional for Recover) Min.1.5-inch, One or more layers,any combination, loose laid

Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof Board

FlintFast #12 or #14 HD

with FlintFast 3"

Insulation Plates

1 per1.45ft2 APP-TA(Optional) APP-TA

APP-TA -60.0

W-32

Min. 19/32-inch

exterior grade plywoodat max. 24-inch spans

(Optional for Concrete orRecover) Min. 2-inch ACFoamII, FlintBoard, H-Shield or

ENRGY3, loose laid.

Min. 0.5-inch SECUROCK

Gypsum-Fiber Roof Board

FlintFast #12 or #14 HD

with FlintFast 3"

Insulation Plates

1 per1.78ft2BP-AA, SBS-AA,

SBS-TA or APP-

TA

(Optional) BP-AA, SBS-AA, SBS-

TA or APP-TA

SBS-AA, SBS-TA

or APP-TA-60.0

W-33

Min. 15/32-inch

plywood at max. 24-inch spans

(Optional for Recover) Min.1.5-inch, One or more layers,

any combination, loose laid

Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof Board

FlintFast #12 or #14 HD

with FlintFast 3"

insulation Plates

1 per 1.33ft2 APP-TA(Optional) APP-TA

APP-TA -67.5

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017Appendix 1, Page 9 of 57

TRINITY ERDTABLE ID: WOOD DECKS - NEWCONSTRUCTION, REROOF (Tear-Off) or RECOVER

SYSTEMTYPE D: INSULATED, MECHANICALLY ATTACHED BASESHEET, BONDED ROOF COVER

System

No.

Deck

(Note 1)

Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP

(psf)Type Attach Base Fasteners Attach Ply CapSelf-Adhering Systems:

W-34

Min. 19/32-inch

plywood at max 24-

inch spans

Min. 1.5-inch, One

or more layers,

any combination

Prelim.

AttachFlintlastic SA NailBase Note 2

8-inch o.c. at min. 3-inch lap and 8-inch o.c. in two (2), equally spaced,staggered center rows; Stress platesshall be primed with FlintPrime

(ASTM D41) primer or FlintPrime SA

(Optional)

SBS-SASBS-SA -82.5*

W-35

Min. 15/32-inch

plywood at max 24-

inch spans

Min. 1.5-inch, One

or more layers,

any combination

Prelim.

AttachFlintlastic SA NailBase

Flintfast 3 in. Insulation Plates

with FlintFast #12 or #14;Trufast 3" Metal Insulation

Plates with DP or HD; OMG 3

in. Round Metal Plates with

OMG#14HD

6-inch o.c. at min. 2-inch lap and 6-inch o.c. in three (3), equally spaced,staggered center rows; Stress platesshall be primed with FlintPrime(ASTM D41) primer or FlintPrime SA.

(Optional)SBS-SA

SBS-SA -97.5*

W-36

Min. 15/32-inch

plywood at max 24-

inch spans

Min. 1.5-inch, One

or more layers,

any combination

Prelim.

AttachFlintlastic SA NailBase

Flintfast 3 in. Insulation Plates

with FlintFast #12 or #14;Trufast 3" Metal Insulation

Plates with DP or HD; OMG 3

in. Round Metal Plates with

OMG #14 HD

6-inch o.c. at min. 2-inch lap and 6-inch o.c. in four (4), equally spaced,staggered center rows; Stress platesshall be primed with FlintPrime(ASTM D41) primer or FlintPrime SA.

(Optional)SBS-SA

SBS-SA -127.5*

Hybrid Systems:

W-37

Min. 15/32-inchplywood at max 24-inch spans

Min. 1.5-inch, One

or more layers,any combination

Prelim.

Attach

Glasbase; Flexiglas;Flintlastic Base 20; Poly SMSBase; Ultra Poly SMS Base

Flintfast 3 in. Insulation Plates

with FlintFast #12 or #14;Trufast 3" Metal Insulation

Plates with DP or HD; OMG 3

in. Round Metal Plates with

OMG #14 HD

6-inch o.c. at 4-inch lap and 6-incho.c. in three (3), equally spaced,staggered center rows; Stress platesshall be primed with FlintPrime

(ASTM D41) primer or FlintPrime SA.

SBS-SA-HSBS-AA, SBS-

TA or APP-TA-97.5

W-38

Min. 19/32-inch

plywood at max 24-

inch spans

Min. 1.5-inch, One

or more layers,

any combination

Prelim.

Attach

Glasbase; Flexiglas;Flintlastic Base 20; Poly SMSBase; Ultra Poly SMS Base

Note 2

7-inch o.c. at 3-inch lap and 7-incho.c. in three (3), equally spaced,staggered center rows

SBS-SA-HSBS-AA, SBS-

TA or APP-TA-105.0

W-39

Min. 15/32-inch

plywood at max 24-inch spans

Min. 1.5-inch, One

or more layers,

any combination

Prelim.

Attach

Glasbase; Flexiglas;Flintlastic Base 20; Poly SMSBase; Ultra Poly SMS Base

Flintfast 3 in. Insulation Plates

with FlintFast #12 or #14;Trufast 3" Metal Insulation

Plates with DP or HD;OMG 3in. Round Metal Plates with

OMG #14 HD

6-inch o.c. at 4-inch lap and 6-incho.c. in four (4), equally spaced,staggered center rows; Stress platesshall be primed with FlintPrime(ASTM D41) primer or FlintPrime SA.

SBS-SA-HSBS-AA, SBS-

TA or APP-TA-127.5

Conventional Systems:

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666,M EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 10 of 57

TRINITY ERD

TABLE ID: WOOD DECKS - NEW CONSTRUCTION,REROOF(Tear-Off) or RECOVER

SYSTEM TYPE D: INSULATED. MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER

System

No.

Deck

(Note 1)

Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP

(psf)Type Attach Base Fasteners Attach Ply Cap

W-40

Min. 23/32-inch

exterior gradeplywood at max. 24-inch spans

Min. 1.5-inch, One

or more layers,

any combination

Prelim.

Attach

Glasbase; All

Weather/Empire Base;Flexiglas Base; FlintlasticBase 20; Yosemite

Note 2

12-inch o.c. at 4-inch lap and 36-inch

o.c. in two (2), equally spaced,staggered center rows

BP-AA, SBS-

AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-30.0*

W-41

Min. 23/32-inch

exterior gradeplywood at max. 24-inch spans

Min. 1.5-inch, One

or more layers,

any combination

Prelim.

Attach

Glasbase; AllWeather/Empire Base;Flexiglas Base; FlintlasticBase 20; Yosemite

Note 2

12-inch o.c. at 4-inch lap and 24-inch

o.c. in two (2), equally spaced,staggered center rows

BP-AA, SBS-

AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-45.0*

W-42

Min. 23/32-inchexterior gradeplywood at max. 24-inch spans

Min. 1.5-inch, One

or more layers,

any combination

Prelim.

Attach

Poly SMS Base; Ultra PolySMS Base

Note 2

12-inch o.c. at 4-inch lap and 36-incho.c. in two (2), equally spaced,staggered center rows

BP-AA, SBS-

AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-45.0*

W-43

Min. 15/32-inchplywood at max 24-

inch spans

Min. 1.5-inch, One

or more layers,

any combination

Prelim.

Attach

Glasbase; Flexiglas;Flintlastic Base 20; All

Weather/ Empire Base;Poly SMS Base; Ultra PolySMS Base; Yosemite

Flintfast 3 in. Insulation Plates

with FlintFast #12 or #14;

Trufast 3" Metal Insulation

Plates with DP or HD; OMG 3

in. Round Metal Plates with

OMG#14HD

6-inch o.c. at 4-inch lap and 6-incho.c. in three (3), equally spaced,staggered center rows.

(Optional) BP-AA, SBS-AA,

SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-97.5

W-44

Min. 15/32-inchplywood at max 24-inch spans

Min. 1.5-inch, One

or more layers,

any combination

Prelim.

AttachFlintlastic APP Base T

OMG 3 in. Round Metal Plates

with OMG #14 HD

6-inch o.c. at 4-inch lap and 6-inch

o.c. in three (3), equally spaced,staggered center rows.

APP-TA APP-TA -97.5

W-45

Min. 15/32-inchplywood at max 24-inch spans

One or more

layers, anythickness or

combination

Prelim.

Attach

Glasbase; Flexiglas;Flintlastic Base 20; All

Weather/ Empire Base;Poly SMS Base; Ultra PolySMS Base; Yosemite

Flintfast 3 in. Insulation Plates

with FlintFast #14; Trufast 3"Metal Insulation Plates with

Trufast HD

8-inch o.c. at 4-inch lap and 8-incho.c. at three (3) equally spaced,staggered center rows

(Optional) BP-AA, SBS-AA,

SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP_TA-97.5

W-46

Min. 19/32-inchplywood at max 24-inch spans

Min. 1.5-inch, One

or more layers,any combination

Prelim.

Attach

Glasbase; Flexiglas;Flintlastic Base 20; Poly SMSBase; Ultra Poly SMS Base;Yosemite

Note 2

7-inch o.c. at 3-inch lap and 7-incho.c. in three (3), equally spaced,staggered center rows

BP-AA, SBS-

AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-105.0

W-47

Min. 19/32-inchplywood at max 24-inch spans

Min. 1.5-inch, One

or more layers,any combination

Prelim.

AttachFlintlastic APP Base T

OMG 3 in. Round Metal Plates

with OMG #14 HD or Dekfast

Hex Plate with Dekfast #14

7-inch o.c. at 3-inch lap and 7-incho.c. in three (3), equally spaced,staggered center rows

APP-TA APP-TA -105.0

W-48

Min. 15/32-inchplywood at max 24-inch spans

Min. 1.5-inch, One

or more layers,

any combination

Prelim.

Attach

Glasbase; Flexiglas;

Flintlastic Base 20; Poly SMSBase; Ultra Poly SMS Base;Yosemite

Flintfast 3 in. Insulation Plates

with FlintFast #12 or #14;

Trufast 3" Metal Insulation

Plates with DP or HD; OMG 3in. Round Metal Plates with

OMG #14 HD

6-inch o.c. at 4-inch lap and 6-incho.c. in four (4), equally spaced,staggered center rows.

(Optional) BP-AA, SBS-AA,

SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-127.5

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 11 of 57

TRINITY ERDTABLE ID: WOOD DECKS- NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVER

SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER

System

No.

Deck

(Note 1)

Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP

(psf)Type Attach Base Fasteners Attach Ply Cap

W-49

Min. 15/32-inch

plywood at max 24-inch spans

Min. 1.5-inch, One

or more layers,

any combination

Prelim.

AttachFlintlastic APP Base T

OMG 3 in. Round Metal Plates

with OMG #14 HD

6-inch o.c. at 4-inch lap and 6-incho.c. in four (4), equally spaced,staggered center rows.

APP-TA APP-TA -127.5

Cold-Applied Systems:

W-50

Min. 15/32-inchplywood at max 24-

inch spans

Min. 1-inch, One

or more layers,

any combination

Loose-

laid

Glasbase; Flexiglas Base;Flintlastic Base 20; All

Weather / Empire Base;Yosemite Venting Base;

Flintlastic Poly SMS Base;Flintlastic Ultra Poly SMSBase

Flintfast 3 in. Insulation Plates

with FlintFast #12 or #14;

Trufast 3" Metal Insulation

Plates with DP or HD

8-inch o.c. at 4-inch lap and 8-inch

o.c. in three (3), equally spaced,staggered center rows

(Optional)SBS-CAl

SBS-CAl -52.5

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19

Revision 20: 09/14/2017Appendix 1, Page 12 of 57

System

No.

Deck

(Note 1)

Self-Adhering Systems:

W-51

W-52

W-53

W-54

W-55

W-56

W-57

W-58

Min. 15/32-inch plywood at

max 24-inch spans

Min. 15/32-inch plywood at

max 24-inch spans

Min. 19/32-inch plywood at

max. 24-inch spans

Min. 19/32-inch plywood at

max. 24-inch spans

Min. 15/32-inch plywood atmax 24-inch spans

Min. 19/32-inch plywood at

max 24-inch spans

Min. 15/32-inch plywood atmax 24-inch spans

Min. 19/32-inch plywood atmax 24-inch spans

Hybrid Systems:

W-59

W-60

Min. 19/32-inch exterior gradeplywood at max. 24-inch spans

Min. 15/32-inch plywood atmax 24-inch spans

TABLE 1E-1: WOOD DECKS-NEW CONSTRUCTION or REROOF (Tear-Off)SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER

Base Sheet

Base

Flintlastic SA NailBase

Flintlastic SA NailBase

Flintlastic SA NailBase

Flintlastic SA NailBase

Flintlastic SA NailBase

Flintlastic SA NailBase

Flintlastic SA NailBase

Flintlastic SA NailBase

Glasbase; Flexiglas; FlintlasticBase 20; Ail Weather/ Empire

Base; Poly SMS Base; Ultra PolySMS Base

Glasbase; Flexiglas; FlintlasticBase 20; All Weather / EmpireBase; Poly SMS Base; Ultra PolySMS Base

Fasteners

Simplex MAXX Cap

Min. 1-inch long, 12 ga. Simplex

Metal Cap Nails

32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails

32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails

Simplex MAXX Cap

32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails

Cap nails: 1-inch diameter,0.032-inch thick metal cap with0.120" shank diameter, annular

ring shanknails

32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shank

nails

32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails

Min. 1-inch long, 12 ga. SimplexMetal Cap Nails

Attach

9-inch o.c. at min. 3-inch lap and 12-inch o.c. intwo (2), equally spaced, staggered center rows;Stress plates shall be primed with FlintPrime(ASTM D41) primer.

6-inch o.c. at min. 2-inch lap and 6-inch o.c. infour (4), equally spaced, staggered center rows

8-inch o.c. at min. 2-inch lap and 8-inch o.c. inthree (3), equally spaced, staggered centerrows

8-inch o.c. at min. 2-inch lap and 8-inch o.c. in

three (3), equally spaced, staggered centerrows

8-inch o.c. at min. 3-inch lap and 8-inch o.c. in

three (3), equally spaced, staggered centerrows; Stress plates shall be primed withFlintPrime (ASTM D41) primer.

6-inch o.c. at min. 2-inch lap and 6-inch o.c. in

four (4), equally spaced, staggered center rows

7-inch o.c. at min. 4-inch laps and 7-inch o.c. infive (5), equally spaced, staggered center rows

4-inch o.c. at min. 2-inch lap and 4-inch o.c. infour (4), equally spaced, staggered center rows

9-inch o.c. at 4-inch lap and 12-inch o.c. in two

(2), equally spaced, staggered center rows

6-inch o.c. at 3-inch lap and 6-inch o.c. in four(4), equally spaced, staggered center rows

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

TRINITY ERD

Roof Cover (Note 14)

Ply

(Optional) SBS-

SA

(Optional) SBS-SA

(Optional) SBS-SA

(Optional) SBS-SA

(Optional) SBS-SA

(Optional) SBS-SA

(Optional) SBS-SA

(Optional) SBS-SA

SBS-SA-H

SBS-SA-H

Cap

SBS-SA

SBS-SA

SBS-SA

SBS-SA

SBS-SA

SBS-SA

SBS-SA

SBS-SA

SBS-AA, SBS-TA

or APP-TA

SBS-AA, SBS-TA

or APP-TA

MDP

(psf)

-45.0*

-52.5

-52.5

-60.0

-67.5

-75.0

-75.0

-105.0

-45.0*

-52.5

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 13 of 57

TRINITY ERDTABLE 1E-1: WOOD DECKS- NEW CONSTRUCTION or REROOF (Tear-Off)

SYSTEMTYPEE: NON-INSULATED, MECHANICALLY ATTACHED BASESHEET,BONDED ROOF COVER

System

No.

Deck

(Note 1)

Base Sheet Roof Cover (Note 14) MDP

(psf)Base Fasteners Attach Ply Cap

W-61Min. 19/32-inch plywood atmax 24-inch spans

Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; Ultra

Poly SMS Base

32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails

8-inch o.c. at 4-inch lap and 8-inch o.c. in three(3), equally spaced, staggered center rows

SBS-SA-HSBS-AA, SBS-TA

or APP-TA-52.5

W-62Min. 19/32-inch plywood atmax 24-inch spans

Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; UltraPoly SMS Base

32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails

8-inch o.c. at 4-inch lap and 8-inch o.c. in three(3), equally spaced, staggered center rows

SBS-SA-HSBS-AA, SBS-TA

or APP-TA-60.0

W-63Min. 19/32-inch plywood atmax 24-inch spans

Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; UltraPoly SMS Base

32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails

6-inch o.c. at 4-inch lap and 6-inch o.c. in four(4), equally spaced, staggered center rows SBS-SA-H

SBS-AA, SBS-TA

or APP-TA-82.5

W-64Min. 19/32-inch plywood atmax 24-inch spans

Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; UltraPoly SMS Base

32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails

4-inch o.c. at 3-inch lap and 4-inch o.c. in four(4), equally spaced, staggered center rows SBS-SA-H

SBS-AA, SBS-TA

or APP-TA-105.0

Conventional Systems:

W-65Min. 19/32-inch exterior gradeplywood at max. 24-inch spans

Glasbase; Flexiglas; FlintlasticBase 20; AllWeather/ EmpireBase; Poly SMS Base; Ultra Poly

SMS Base; Yosemite

32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails

9-inch o.c. at 4-inch lap and 12-inch o.c. in two(2), equally spaced, staggered center rows

BP-AA, SBS-AA,

SBS-TA or APP-

TA

SBS-AA, SBS-TA

or APP-TA-45.0*

W-66Min. 15/32-inch exterior gradeplywood at max. 24-inch spans

Glasbase; Flexiglas; FlintlasticBase 20; All Weather / EmpireBase; Poly SMS Base; Yosemite

Simplex MAXX Cap9-inch o.c. at 2-inch lap and 18-inch o.c. in two(2), equally spaced, staggered center rows

(Optional) BP-AA, SBS-AA, SBS-

TA or APP-TA

SBS-AA, SBS-TA

or APP-TA-45.0*

W-67Min. 15/32-inch exterior gradeplywood at max. 24-inch spans

Flintlastic APP Base T Simplex MAXXCap9-inch o.c. at 2-inch lap and 18-inch o.c. in two(2), equally spaced, staggered center rows

(Optional) APP-TA

APP-TA -45.0*

W-68Min. 15/32-inch plywood atmax 24-inch spans

Glasbase; Flexiglas; FlintlasticBase 20; All Weather / EmpireBase; Poly SMS Base; Ultra PolySMS Base; Yosemite

Min. 1-inch long, 12 ga. SimplexMetal Cap Nails

6-inch o.c. at 3-inch lap and 6-inch o.c. in four(4), equally spaced, staggered center rows

(Optional) BP-AA, SBS-AA, SBS-

TA or APP-TA

SBS-AA, SBS-TA

or APP-TA-52.5

W-69Min. 19/32-inch plywood atmax 24-inch spans

Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; UltraPoly SMS Base; Yosemite

32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails

8-inch o.c. at 4-inch lap and 8-inch o.c. in three(3), equally spaced, staggered center rows

BP-AA, SBS-AA,

SBS-TA or APP-

TA

SBS-AA, SBS-TA

or APP-TA-52.5

W-70Min. 15/32-inch exterior gradeplywood at max. 24-inch spans

Glasbase; Flexiglas; FlintlasticBase 20; AllWeather / EmpireBase; Poly SMS Base; Yosemite

Simplex MAXX Cap9-inch o.c. at 2-inch lap and 12-inch o.c. in two(2), equally spaced, staggered center rows

(Optional) BP-AA, SBS-AA, SBS-

TA or APP-TA

SBS-AA, SBS-TA

or APP-TA-52.5

W-71Min. 15/32-inch exterior gradeplywood at max. 24-inch spans

Flintlastic APP Base T Simplex MAXX Cap9-inch o.c. at 2-inch lap and 12-inch o.c. in two(2), equally spaced, staggered center rows

(Optional) APP-TA

APP-TA -52.5

W-72Min. 19/32-inch plywood atmax 24-inch spans

Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; UltraPoly SMS Base; Yosemite

32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails

8-inch o.c. at 4-inch lap and 8-inch o.c. in three(3), equally spaced, staggered center rows

BP-AA, SBS-AA,

SBS-TA or APP-

TA

SBS-AA, SBS-TA

or APP-TA-60.0

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 14 of 57

System

No.

W-73

W-74

W-75

W-76

W-77

W-78

W-79

Deck

(Note 1)

Min. 15/32-inch plywood atmax 24-inch spans

Min. 19/32-inch plywood atmax 24-inch spans

Min. 15/32-inch exterior gradeplywood at max. 24-inch spans

Min. 15/32-inch exterior gradeplywood at max. 24-inch spans

Min. 19/32-inch plywood atmax 24-inch spans

Min. 15/32-inch exterior gradeplywood at max. 24-inch spans

Min. 15/32-inch exterior gradeplywood at max. 24-inch spans

TABLE 1E-1: WOOD DECKS- NEW CONSTRUCTION or REROOF (Tear-Off)

SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER

Base

Glasbase; Flexiglas; FlintlasticBase 20; AllWeather / EmpireBase; Poly SMS Base; Ultra PolySMS Base; Yosemite

Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; UltraPoly SMS Base; Yosemite

Glasbase; Flexiglas; FlintlasticBase 20; AllWeather / EmpireBase; Poly SMS Base; Yosemite

Flintlastic APP Base T

Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; UltraPoly SMS Base; Yosemite

Glasbase; Flexiglas; FlintlasticBase 20; AllWeather / EmpireBase; Poly SMS Base; Yosemite

Flintlastic APP Base T

Base Sheet

Fasteners

Cap nails: 1-inch diameter,0.032-inch thick metal cap with0.120-inch shank diameter,

annular ring shank nails.

32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails

Simplex MAXX Cap

Simplex MAXXCap

32 ga., 1-5/8-inch dia. tin capswith 11 ga. annular ring shanknails

Simplex MAXX Cap

Simplex MAXXCap

Attach

6-inch o.c. at 4-inch lap and 6-inch o.c. at five(5) equally spaced, staggered center rows

6-inch o.c. at 4-inch lap and 6-inch o.c. in four(4), equally spaced, staggered center rows

6-inch o.c. at 2-inch lap and 6-inch o.c. in two(2), equally spaced, staggered center rows

6-inch o.c. at 2-inch lap and 6-inch o.c. in two(2), equally spaced, staggered center rows

4-inch o.c. at 3-inch lap and 4-inch o.c. in four(4), equally spaced, staggered center rows

6-inch o.c. at 2-inch lap and 6-inch o.c. in three(3), equally spaced, staggered center rows

6-inch o.c. at 2-inch lap and 6-inch o.c. in three(3), equally spaced, staggered center rows

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

TRINITY ERD

Roof Cover (Note 14)

Ply

(Optional) BP-AA, SBS-AA or

SBS-TA

BP-AA, SBS-AA,

SBS-TA or APP-

TA

(Optional) BP-AA, SBS-AA,SBS-

TA or APP-TA

(Optional) APP-TA

BP-AA, SBS-AA,

SBS-TA or APP-

TA

(Optional) BP-AA, SBS-AA, SBS-

TA or APP-TA

(Optional) APP-TA

Cap

SBS-AA or SBS-

TA

SBS-AA, SBS-TA

or APP-TA

SBS-AA, SBS-TA

or APP-TA

APP-TA

SBS-AA, SBS-TA

or APP-TA

SBS-AA, SBS-TA

or APP-TA

APP-TA

MDP

(psf)

-67.5

-82.5

-90.0

-90.0

-105.0

-105.0

-105.0

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 15 of 57

TRINITY ERDTABLE 1E-2: WOOD DECKS - NEW CONSTRUCTION, REROOF(Tear-Off) or RECOVER

SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER

System

No.

Deck

(Note 1)

Base Sheet Roof Cover (Note 14) MDP

(psf)Base Fasteners Attach Ply Cap

Self-Adhering Systems:

W-80Min. 19/32-inch plywoodat max 24-inch spans

Flintlastic SA NailBase Note 2

8-inch o.c. at min. 3-inch lap and 8-inch o.c. in

two (2), equally spaced, staggered center rows.Stress plates shall be primed with FlintPrime(ASTM D41) primer or FlintPrime SA

(Optional)

SBS-SASBS-SA -82.5*

W-81Min. 15/32-inch plywoodat max 24-inch spans

Flintlastic SA NailBase

Flintfast 3 in. Insulation Plates with

FlintFast #12 or #14; Trufast 3" Metal

Insulation Plates with DP or HD; OMG 3

in. Round Metal Plates with OMG #14 HD

6-inch o.c. at min. 2-inch lap and 6-inch o.c. in

three (3), equally spaced, staggered center rows.Stress plates shall be primed with FlintPrime

(ASTM D41) primer or FlintPrime SA.

(Optional)SBS-SA

SBS-SA -97.5*

W-82Min. 15/32-inch plywoodat max 24-inch spans

Flintlastic SA NailBase

Flintfast 3 in. Insulation Plates with

FlintFast #12 or #14; Trufast 3" Metal

Insulation Plates with DP or HD;OMG 3in. Round Metal Plates with OMG #14 HD

6-inch o.c. at min. 2-inch lap and 6-inch o.c. infour (4), equally spaced, staggered center rows.Stress plates shall be primed with FlintPrime(ASTM D41) primer or FlintPrime SA.

(Optional)

SBS-SASBS-SA -127.5*

Hybrid Systems:

W-83Min. 15/32-inch plywoodat max 24-inch spans

Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; UltraPoly SMS Base

Flintfast 3 in. Insulation Plates with

FlintFast #12 or #14; Trufast 3" Metal

Insulation Plates with DP or HD; OMG 3in. Round Metal Plates with OMG #14 HD

6-inch o.c. at 4-inch lap and 6-inch o.c. in three(3), equally spaced, staggered center rows.Stress plates shall be primed with FlintPrime(ASTM D41) primer or FlintPrime SA.

SBS-SA-HSBS-AA, SBS-

TA or APP-TA-97.5

W-84Min. 19/32-inch plywoodat max 24-inch spans

Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; UltraPoly SMS Base

Note 27-inch o.c. at 3-inch lap and 7-inch o.c. in three(3), equally spaced, staggered center rows SBS-SA-H

SBS-AA, SBS-

TA or APP-TA-105.0

W-85Min. 15/32-inch plywoodat max 24-inch spans

Glasbase; Flexiglas; Flintlastic

Base 20; Poly SMS Base; UltraPoly SMS Base

Flintfast 3 in. Insulation Plates with

FlintFast #12 or #14; Trufast 3" Metal

Insulation Plates with DP or HD; OMG 3

in. Round Metal Plates with OMG #14 HD

6-inch o.c. at 4-inch lap and 6-inch o.c. in four(4), equally spaced, staggered center rows.Stress plates shall be primed with FlintPrime(ASTM D41) primer or FlintPrime SA.

SBS-SA-HSBS-AA, SBS-

TA or APP-TA-127.5

Conventional Systems:

W-86

Min. 23/32-inch exterior

grade plywood at max.24-inch spans

Glasbase; All Weather/EmpireBase; Flexiglas Base; FlintlasticBase 20; Yosemite

Note 212-inch o.c. at 4-inch lap and 36-inch o.c. in two(2), equally spaced, staggered center rows

BP-AA, SBS-

AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-30.0*

W-87

Min. 23/32-inch exterior

grade plywood at max.24-inch spans

Glasbase; All Weather/EmpireBase; Flexiglas Base; FlintlasticBase 20; Yosemite

Note 212-inch o.c. at 4-inch lap and 24-inch o.c. in two

(2), equally spaced, staggered center rows

BP-AA, SBS-

AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-45.0*

W-88

Min. 23/32-inch exteriorgrade plywood at max.24-inch spans

Poly SMS Base; Ultra Poly SMSBase

Note 212-inch o.c. at 4-inch lap and 36-inch o.c. in two(2), equally spaced, staggered center rows

BP-AA, SBS-

AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-45.0*

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19

Revision 20: 09/14/2017Appendix 1, Page 16 of 57

System

No.

W-89

W-90

W-91

W-92

W-93

W-94

W-95

Deck

(Note 1)

Min. 15/32-inch plywoodat max 24-inch spans

Min. 15/32-inch plywoodat max 24-inch spans

Min. 15/32-inch plywood

at max 24-inch spans

Min. 19/32-inch plywoodat max 24-inch spans

Min. 19/32-inch plywoodat max 24-inch spans

Min. 15/32-inch plywoodat max 24-inch spans

Min. 15/32-inch plywoodat max 24-inch spans

TABLE1E-2: WOOD DECKS - NEW CONSTRUCTION,REROOF(Tear-Off) or RECOVER

SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER

Base

Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; UltraPoly SMS Base; Yosemite

Flintlastic APP Base T

Glasbase; Flexiglas; FlintlasticBase 20; All Weather / EmpireBase; Poly SMS Base; Ultra PolySMS Base; Yosemite

Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; UltraPoly SMS Base; Yosemite

Flintlastic APP Base T

Glasbase; Flexiglas; FlintlasticBase 20; Poly SMS Base; UltraPoly SMS Base; Yosemite

Flintlastic APP Base T

Base Sheet

Fasteners

Flintfast 3 in. Insulation Plates with

FlintFast #12 or #14; Trufast 3" MetalInsulation Plates with DP or HD; OMG 3

in. Round Metal Plates with OMG #14 HD

OMG 3 in. Round Metal Plates with OMG

#14 HD

Flintfast 3 in. Insulation Plates with

FlintFast #14; Trufast 3" Metal InsulationPlates with Trufast HD

Note 2

OMG 3 in. Round Metal Plates with OMG

#14 HD or Dekfast Hex Plate with Dekfast

#14

Flintfast 3 in. Insulation Plates with

FlintFast #12 or #14; Trufast 3" MetalInsulation Plates with DP or HD; OMG 3

in. Round Metal Plates with OMG #14 HD

OMG 3 in. Round Metal Plates with OMG

#14 HD

Attach

6-inch o.c. at 4-inch lap and 6-inch o.c. in three(3), equally spaced, staggered center rows

6-inch o.c. at 4-inch lap and 6-inch o.c. in three(3), equally spaced, staggered center rows.

8-inch o.c. at 4-inch lap and 8-inch o.c. at three(3) equally spaced, staggered center rows

7-inch o.c. at 3-inch lap and 7-inch o.c. in three(3), equally spaced, staggered center rows

7-inch o.c. at 3-inch lap and 7-inch o.c. in three(3), equally spaced, staggered center rows

6-inch o.c. at 4-inch lap and 6-inch o.c. in four(4), equally spaced, staggered center rows

6-inch o.c. at 4-inch lap and 6-inch o.c. in four(4), equally spaced, staggered center rows.

TRINITY ERD

Roof Cover (Note 14)

Ply

(Optional) BP-AA, SBS-AA,

SBS-TA or

APP-TA

APP-TA

(Optional) BP-AA, SBS-AA or

SBS-TA

BP-AA, SBS-

AA, SBS-TA or

APP-TA

APP-TA

(Optional) BP-AA, SBS-AA,

SBS-TA or

APP-TA

APP-TA

Cap

SBS-AA, SBS-

TA or APP-TA

APP-TA

SBS-AA or

SBS-TA

SBS-AA, SBS-

TA or APP-TA

APP-TA

SBS-AA, SBS-TA or APP-TA

APP-TA

MDP

(psf)

-97.5

-97.5

-97.5

-105.0

-105.0

-127.5

-127.5

Cold-Applied Systems:

W-96Min. 15/32-inch plywoodat max 24-inch spans

Glasbase; Flexiglas Base;Flintlastic Base 20; All Weather /Empire Base; Yosemite VentingBase; Flintlastic Poly SMS Base;Flintlastic Ultra Poly SMS Base

Flintfast 3 in. Insulation Plates with

FlintFast #12 or #14; Trufast 3" MetalInsulation Plates with DP or HD

8-inch o.c. at 4-inch lap and 8-inch o.c. in three(3), equally spaced, staggered center rows

(Optional)SBS-CAl

SBS-CAl -52.5

System

No.

W-97

W-98

Deck

(Note 1)

Min. 15/32-inch plywood at max 24-inch spans

Min. 15/32-inch plywood at max 24-inch spans

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

TABLE IF: WOOD DECKS - NEW CONSTRUCTION OR REROOF (Tear-Off)

SYSTEM TYPE F:NON-INSULATED, BONDED ROOF COVER

PrimerRoof Cover (Note 14)

Base Ply

FlintPrime or FlintPrime SA SBS-SA-H (Optional) SBS-TA, APP-TA

FlintPrime or FlintPrime SA SBS-SA (Optional) SBS-SA

6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

CapMDP (psf)

SBS-TA, APP-TA -112.5

SBS-SA -127.5

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 17 of 57

TRINITY ERDTABLE 2A: STEEL ORSTRUCTURAL CONCRETE DECKS-NEWCONSTRUCTION, REROOF (Tear-Off)or RECOVER

SYSTEMTYPE B: MECHANICALLY ATTACHED BASEINSULATION, BONDED TOP INSULATION, BONDED ROOF COVER

System

No.

Deck

(Note 1)

Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP

(psf)Type Fasteners Attach Type Attach Base Ply CapSelf-Adhering Systems:

S-l

Min. 22 ga., type B, Grade

33 steel or min. 2,500 psistructrual concrete

Min. 2-inch ACFoam II,

FlintBoard, ENRGY 3 or

H-Shield

Note 21 per 4

ft2Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof Board

HA, D-IS, M-

OSFA, OB500

or CR-20

SBS-SA (Optional) SBS-SA SBS-SA -37.5*

S-2

Min. 22 ga., type B, Grade

33 steel or min. 2,500 psistructrual concrete

Min. 1.5-inch ACFoam

II, FlintBoard, ENRGY3or H-Shield

Note 21 per 2

ft2Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof Board

HA, D-IS, M-

OSFA, OB500or CR-20

SBS-SA (Optional) SBS-SA SBS-SA -45.0*

Hybrid Systems:

S-3

Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete

Min. 1.5-inch ACFoam

II, FlintBoard, ENRGY3

or H-Shield

Note 21 per

1.45 ft2Additional layer(s) baseinsulation

HA, D-IS, M-

OSFA, OB500

or CR-20

Flintlastic

Ultra

Glass SA

(Optional) SBS-AA,SBS-TA, APP-TA

SBS-AA,

SBS-TA,

APP-TA

-37.5

S-4

Min. 22 ga., type B, Grade

33 steel or min. 2,500 psistructrual concrete

Min. 1.5-inch ACFoam

II, FlintBoard, ENRGY3

or H-Shield

Note 2lper

1.45 ft2Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof Board

HA, D-IS, M-

OSFA, OB500

or CR-20

Flintlastic

Ultra

Glass SA

(Optional) SBS-AA,SBS-TA, APP-TA

SBS-AA,

SBS-TA,

APP-TA

-52.5

S-5

Min. 22 ga., type B, Grade

33 steel or min. 2,500 psistructrual concrete

Min. 1.5-inch ACFoam

II, FlintBoard ISO, H-Shield or FlintBoard

ISOH.

FlintFast #12 or #14 with

FlintFast 3" Insulation Plates

lper

1.45 ft2

Min. 1.5-inch ACFoam II,FlintBoard ISO, H-Shield or

FlintBoard ISOH.

HA, D-IS, M-

OSFA, M-

PGlor

OB500

SBS-SA-H (Optional) APP-TA APP-TA -67.5

S-6

Min. 22 ga., type B, Grade40 steel or min. 2,500 psistructrual concrete

Min. 1.5-inch ACFoam

II, FlintBoard ISO, H-

Shield or FlintBoard

ISO„

FlintFast 012 (steel only) or 014HD with FlintFast 3" Insulation

Plates or Trufast 012 (steel only)or HD with Trufast 3" Metal

Insulation Plates

1 per 1.6

ft2Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof Board

D-IS, M-

OSFA, M-

PGlor

OB500

SBS-SA-H(Optional) SBS-TAor APP-TA

SBS-TA or

APP-TA-75.0

S-7

Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete

Min. 1.5-inch ENRGY 3

FlintFast 012 (steel only) or 014HD with FlintFast 3" Insulation

Plates or Trufast 012 (steel only)or HD with Trufast 3" Metal

Insulation Plates

1 perl

ft2Min. 0.5-inch SECUROCK

Gypsum-Fiber Roof BoardOB500, 4-

inch o.c.SBS-SA-H

(Optional) SBS-TAor APP-TA

SBS-TA or

APP-TA-90.0*

Conventional Systems:

S-8

Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete

Min. 2-inch ACFoam II,

FlintBoard, ENRGY3 orH-Shield

Note 2lper 4

ft2Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof Board

HA, D-IS, M-

OSFA, OB500

or CR-20

BP-AA,

SBS-AA,

SBS-TA or

APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-37.5*

S-9

Min. 22 ga., type B, Grade

33 steel or min. 2,500 psistructrual concrete

Min. 1.5-inch ACFoam

II, FlintBoard, ENRGY3or H-Shield

Note 2lper 2

ft2

Min. 0.5-inch Structodek

High Density FiberboardRoof Insulation, min. 0.75-inch FescoBoard

(homogeneous).

HABP-AA or

SBS-AA

(Optional) BP-AA,

SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-45.0*

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic*Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19

Revision 20: 09/14/2017

Appendix 1, Page 18 of 57

TRINITY ERD

TABLE 2A: STEEL ORSTRUCTURAL CONCRETE DECKS - NEWCONSTRUCTION, REROOF (Tear-Off)or RECOVERSYSTEM TYPE B: MECHANICALLY ATTACHED BASEINSULATION, BONDED TOPINSULATION, BONDED ROOF COVER

System

No.

Deck

(Note 1)

Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP

(psf)Type Fasteners Attach Type Attach Base Ply Cap

S-10

Min. 22 ga., type B, Grade33 steel or min. 2,500 psi

structrual concrete

Min. 1.5-inch ACFoam

II, FlintBoard, ENRGY3or H-Shield

Note 21 per 2

ft2Min. 0.25-inch Dens Deck

or Dens Deck PrimeHA

BP-AA,

SBS-AA,

SBS-TA or

APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-45.0*

S-ll

Min. 22 ga., type B, Grade33 steel or min. 2,500 psi

structrual concrete

Min. l.S-inch ACFoam

II, FlintBoard, ENRGY3

or H-Shield

Note 2lper 2

ft2Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof Board

HA, D-IS, M-

OSFA, OB500

or CR-20

BP-AA,

SBS-AA,

SBS-TA or

APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-45.0*

S-12

Min. 22 ga., type B, Grade33 steel or min. 2,500 psi

structrual concrete

Min. 2-inch ACFoam II,

FlintBoard, ENRGY 3 or

H-Shield

Note 2lper 3.2

ft2

Min. 0.5-inch Structodek

High Density FiberboardRoof Insulation, min. 0.75-

inch FescoBoard

(homogeneous).

HABP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-45.0*

S-13

Min. 22 ga., type B, Grade33 steel or min. 2,500 psi

structrual concrete

Min. 2-inch ACFoam II,

FlintBoard, ENRGY 3 or

H-Shield

Note 21 per 3.2

ft2

Min. 0.25-inch Dens Deck

or Dens Deck PrimeHA

BP-AA,

SBS-AA,

SBS-TA or

APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-45.0*

S-14

Min. 22 ga., type B, Grade33 steel or min. 2,500 psi

structrual concrete

Min. 1.5-inch ACFoam

II, FlintBoard, ENRGY 3or Mult-Max FA3

Note 2lper

1.33 ft2

Min. 0.75-inch FescoBoard

(homogeneous)HA

BP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-52.5

S-15

Min. 22 ga., type B, Grade33 steel or min. 2,500 psi

structrual concrete

Min. 2-inch ACFoam II,

FlintBoard, ENRGY3 or

H-Shield

Note 21 per 1.6

ft2Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof Board

HA, D-IS, M-

OSFA, OB500

or CR-20

BP-AA,

SBS-AA,

SBS-TA or

APP-TA

(Optional) BP-AA,SBS-AA,SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-60.0

S-16

Min. 22 ga., type B, Grade33 steel or min. 2,500 psi

structrual concrete

Min. l.S-inch ACFoam

II, FlintBoard, ENRGY 3or Mult-Max FA3

Note 21 per

1.33 ft2Min. 0.5-inch Structodek

High Density FiberboardHA

BP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-67.5

S-17

Min. 22 ga., type B,Grade40 steel or min. 2,500 psistructrual concrete

Min. 1.5-inch ACFoam

II, FlintBoard ISO, H-

Shield or FlintBoard

iso„

FlintFast 012 (steel only) or 014HD with FlintFast 3" Insulation

Plates or Trufast 012 (steel only)or HD with Trufast 3" Metal

Insulation Plates

1 per 1.6

ft2

Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof Board

D-IS, M-

OSFA, M-

PGlor

OB500

BP-AA,

SBS-AA,

SBS-TA or

APP-TA

(Optional) BP-AA,SBS-AA,SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-75.0

S-18

Min. 22 ga., type B,Grade33 steel or min. 2,500 psistructrual concrete

Min. 1.5-inch ENRGY 3

FlintFast 012 (steel only) or 014HD with FlintFast 3" Insulation

Plates or Trufast 012 (steel only)or HD with Trufast 3" Metal

Insulation Plates

lperl

ft2Min. 0.5-inch SECUROCK

Gypsum-Fiber Roof BoardOB500, 4-

inch o.c.

BP-AA,

SBS-AA,

SBS-TA or

APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-90.0*

Cold-Appued Systems:

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 19 of 57

TRINITY ERDTABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS- NEW CONSTRUCTION, REROOF (Tear-Off) orRECOVER

SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVERSystem

No.

Deck

(Note 1)Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP

(psf)Type Fasteners Attach Type Attach Base Ply Cap

S-19

Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete

Min. 2-inch ACFoam II,FlintBoard ISO, H-Shield or FlintBoard

ISO„

FlintFast 012 (steel only) or 014HD with FlintFast 3" Insulation

Plates or Trufast 012 (steel only)or HD with Trufast 3" Metal

Insulation Plates

lper 2

ft2

Min. 1.5-inch ACFoam III,FlintBoard Iso Cold, H-Shield CG or FlintBoard Iso

Cold„

OB500 or

CR-20SBS-CAl None SBS-CAl -45.0*

S-20

Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete

Min. 2-inch ACFoam II,FlintBoard ISO, H-Shield or FlintBoard

iso„

FlintFast 012 (steel only) or 014HD with FlintFast 3" Insulation

Plates or Trufast 012 (steel only)or HD with Trufast 3" Metal

Insulation Plates

lper 2

ft2

Optional min. 1.5-inch

additional layer(s) baseinsulation, followed bymin. 0.25-inch SECUROCK

Gypsum-Fiber Roof Board

D-IS, M-

OSFA, M-PG1, OB500

or CR-20

SBS-CAl None SBS-CAl -45.0*

S-21

Min. 22 ga., type B, Grade40 steel or min. 2,500 psistructrual concrete

Min. l.S-inch ACFoam

II, FlintBoard ISO, H-Shield or FlintBoard

ISOH

FlintFast 012 (steel only) or 014HD with FlintFast 3" Insulation

Platesor Trufast 012 (steel only)or HD with Trufast 3" Metal

Insulation Plates

lper 1.6

ft2Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof Board

D-IS, M-

OSFA, M-

PGlor

OB500

SBS-CAl None SBS-CAl -75.0

S-22

Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete

Min. 1.5-inch ENRGY 3

FlintFast012 (steel only) or 014HD with FlintFast 3" Insulation

Plates or Trufast 012 (steel only)or HD with Trufast 3" Metal

Insulation Plates

1 perl

ft2Min. 0.5-inch SECUROCK

Gypsum-Fiber Roof BoardOB500, 4-

inch o.c.SBS-CAl None SBS-CAl -90.0*

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen RoofSystems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 20 of 57

TRINITY ERD

TABLE2B: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (Tear-Off) OR RECOVER

SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER

System

No.

Deck

(Note 1)Base Insulation Layer(s)

Top Insulation Layer Roof Cover (Note 14) MDP

(psf)Type Fasteners Attach Base Ply Cap

Self-Adhering Systems:

S-23

Min. 22 ga., type B, Grade33 steel or min. 2,500 psi

structrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. 0.25-inch

SECUROCK Gypsum-

Fiber Roof Board

Note 2 1 per3.2 ft2 SBS-SA (Optional) SBS-SA SBS-SA -30.0*

S-24

Min. 22 ga., type B, Grade33 steel or min. 2,500 psi

structrual concrete

(Optional) One or more

layers, any combination,loose laid

Min. 0.25-inch

SECUROCK Gypsum-

Fiber Roof Board

FlintFast #12 (steel only) or#14 HD with FlintFast 3"

Insulation Plates or Trufast #12

(steel only) or HDwith Trufast3" Metal Insulation Plates

1 per2.7ft2 SBS-SA (Optional) SBS-SA SBS-SA -37.5*

S-25

Min. 22 ga., type B, Grade33 steel or min. 2,500 psi

structrual concrete

(Optional) One or morelayers, any combination,

loose laid

Min. 3/8-inchSECUROCK Gypsum-

Fiber Roof Board

Note 2 lper 2.7 ft2 SBS-SA (Optional) SBS-SA SBS-SA -45.0*

S-26

Min. 22 ga., type B, Grade

33 steel or min. 2,500 psi

structrual concrete

(Optional) One or morelayers, any combination,

loose laid

Min. 0.25-inch Dens

DeckNote 2 1 per1.33ft2

Apply FlintPrime or

FlintPrime SA to

board & plates,

followed by SBS-SA

(Optional) SBS-SA SBS-SA -45.0

S-27

Min. 22 ga., type B, Grade40 steel or min. 2,500 psi

structrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. 1.5-inch

FlintBoard ISO

FlintFast #14 HD with FlintFast

3" Insulation Plates or Trufast

HD with Trufast 3" Metal

Insulation Plates

1 per1.78 ft2Apply FlintPrime to

board & plates,

followed by SBS-SA

(Optional) SBS-SA SBS-SA -67.5

S-28

Min. 22 ga., type B, Grade40 steel or min. 2,500 psi

structrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. 0.5-inch

SECUROCK Gypsum-

Fiber Roof Board

FlintFast #14 HD with FlintFast

3" Insulation Plates or Trufast

HD with Trufast 3" Metal

Insulation Plates

1 per1.6 ft2Apply FlintPrime toboard & plates,

followed by SBS-SA(Optional) SBS-SA SBS-SA -82.5

Hybrid Systems:

S-29

Min. 22 ga., type B, Grade33 steel or min. 2,500 psi

structrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. 0.25-inch Dens

Deck; Dens Deck

Prime

Note 2 1 per2 ft2 SBS-SA-H

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-30.0*

S-30

Min. 22 ga., type B, Grade33 steel or min. 2,500 psi

structrual concrete

(Optional) One or morelayers, any combination,

loose laid

Min. 0.25-inch

SECUROCK Gypsum-

Fiber Roof Board

FlintFast #12 (steel only) or#14 HD with FlintFast 3"

Insulation Plates or Trufast #12

(steel only) or HDwith Trufast3" Metal Insulation Plates

lper 2.7 ft2 SBS-SA-H

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-37.5*

S-31

Min. 22 ga., type B, Grade

33 steel or min. 2,500 psistructrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. 3/8-inch

SECUROCKGypsum-Fiber Roof Board

FlintFast #12 (steel only) or#14 HD with FlintFast 3"

Insulation Plates or Trufast #12

(steel only) or HD with Trufast3" Metal Insulation Plates

lper 2.7 ft2 SBS-SA-H

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-45.0*

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 21 of 57

TRINITY ERDTABLE 2B: STEEL ORSTRUCTURAL CONCRETE DECKS- NEWCONSTRUCTION, REROOF (Tear-Off) or RECOVER

SYSTEM TYPE C: MECHANICALLYATTACHED INSULATION, BONDED ROOFCOVER

System

No.

Deck

(Note 1)Base Insulation Layer(s)

Top Insulation Layer Roof Cover (Note 14) MDP

(psf)Type Fasteners Attach Base Ply Cap

S-32

Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. 1.5-inch ACFoam

II, FlintBoard ISO,

ENRGY 3 or Multi-Max

FA3

Note 2 1 per 1.33 ft2 SBS-SA-H(Optional) BP-AAor SBS-AA

SBS-AA -52.5

S-33

Min. 22 ga., type B, Grade

40 steel or min. 2,500 psistructrual concrete

(Optional) One or more

layers, any combination,loose laid

Min. 1.5-inch

FlintBoard ISO

FlintFast #14 HD with FlintFast

3" Insulation Plates or Trufast

HD with Trufast 3" Metal

Insulation Plates

1 per 1.78 ft2 SBS-SA-H(Optional) SBS-TAor APP-TA

SBS-TA or

APP-TA-67.5

S-34

Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete

(Optional) One or more

layers, any combination,loose laid

Min. l.S-inch ACFoam

II, FlintBoard ISO, H-Shield or FlintBoard

ISOH.

FlintFast #12 (steel only) or#14 HD with FlintFast 3"

Insulation Plates

1 per 1.45 ft2 SBS-SA-H(Optional) SBS-AA,SBS-TA or APP-TA

SBS-AA,

SBS-TA or

APP-TA

-75.0

S-35

Min. 22 ga., type B, Grade40 steel or min. 2,500 psistructrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. 0.5-inch

SECUROCKGypsum-Fiber Roof Board

FlintFast #14 HD with FlintFast

3" Insulation Plates or Trufast

HD with Trufast 3" Metal

Insulation Plates

1 per 1.6 ft2 SBS-SA-H(Optional) SBS-TAor APP-TA

SBS-TA or

APP-TA-82.5

S-36

Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. 0.5-inch

SECUROCKGypsum-Fiber Roof Board

FlintFast #12 (steel only) or#14 HD with FlintFast 3"

Insulation Plates or Trufast #12

(steel only) or HD with Trufast3" Metal Insulation Plates

1 per 1.45ft2 SBS-SA-H(Optional) SBS-TAor APP-TA

SBS-TA or

APP-TA-82.5

S-37

Min. 22 ga., type B, Grade

33 steel or min. 2,500 psistructrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. l.S-inch ACFoam

II, FlintBoard ISO,

ENRGY 3 or Multi-Max

FA3

Note 2 1 per 1.33 ft2 SBS-SA-H(Optional) SBS-TAor APP-TA

SBS-TA or

APP-TA-82.5

S-38

Min. 22 ga., type B, Grade

33 steel or min. 2,500 psistructrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. 0.5-inch

SECUROCKGypsum-Fiber Roof Board

FlintFast #12 (steel only) or#14 HD with FlintFast 3"

Insulation Plates or Trufast #12

(steel only) or HD with Trufast3" Metal Insulation Plates |

1 per 1 ft2 SBS-SA-H(Optional) SBS-TAor APP-TA

SBS-TA or

APP-TA-135.0

Conventional Systems:

S-39

Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. 0.7S-inch

FescoBoard

(homogeneous)Note 2 lper 2.67 ft2 BP-AA, SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-30.0*

S-40

Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. 0.5-inch

Structodek HighDensity FiberboardRoof Insulation

Note 2 1 per 4 ft2 BP-AA, SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TAorAPP-TA

SBS-AA,

SBS-TA or

APP-TA

-37.5*

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666thEDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19

Revision 20: 09/14/2017Appendix 1, Page 22 of 57

TRINITY ERD

TABLE 2B: STEEL ORSTRUCTURAL CONCRETE DECKS- NEWCONSTRUCTION, REROOF (Tear-Off) or RECOVERSYSTEM TYPE C: MECHANICALLYATTACHED INSULATION, BONDED ROOFCOVER

SystemNo.

Deck

(Note 1)Base Insulation Layer(s)

Top Insulation Layer Roof Cover (Note 14) MDP

(psf)Type Fasteners Attach Base Ply Cap

S-41

Min. 22 ga., type B,Grade33 steel or min. 2,500 psi

structrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. 0.25-inch

SECUROCK Gypsum-

Fiber Roof Board

Note 2 1 per4 ft2 BP-AA, SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-37.5*

S-42

Min. 22 ga., type B,Grade33 steel or min. 2,500 psi

structrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. 2-inch ACFoam II,

FlintBoard or ENRGY 3Note 2 1 per1.6ft2 BP-AA2

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-37.5*

S-43

Min. 22 ga., type B, Grade33 steel or min. 2,500 psi

structrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. 0.25-inch

SECUROCKGypsum-

Fiber Roof Board

Note 2 lper 4 ft2BP-AA, SBS-AA,

SBS-TA or APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-45.0*

S-44

Min. 22 ga., type B, Grade33 steel or min. 2,500 psi

structrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. 0.5-inch

Structodek HighDensity FiberboardRoof Insulation, min.

0.75-inch FescoBoard

(homogeneous)

Note 2 1 per 2 ft2 BP-AA or SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-45.0*

S-45

Min. 22 ga., type B, Grade33 steel or min. 2,500 psi

structrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. 0.25-inch Dens

Deck or Dens Deck

Prime

Note 2 1 per 2 ft2BP-AA, SBS-AA,

SBS-TA or APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-45.0*

S-46

Min. 22 ga., type B, Grade33 steel or min. 2,500 psi

structrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. 1-inch

FescoBoard

(homogeneous) ormin. 1.5-inch

FescoBoard

(laminated)

Note 2 1 per 1.6ft2 BP-AA2

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-45.0*

S-47

Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. 0.5-inch

Structodek,

Structodek HD, GP HD

Roof Fiberboard or

Temple HDl or HD6

Note 2 1 per 2 ft2 BP-AA2

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-45.0*

S-48

Min. 22 ga., type B,Grade33 steel or min. 2,500 psistructrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. 1.5-inch ACFoam

II, FlintBoardNote 2 1 per 1.45ft2

BP-AA3, 24-inch

grid

(Optional) BP-AAor SBS-AA

SBS-AA -52.5

S-49

Min. 22 ga., type B, Grade33 steel or min. 2,500 psi

structrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. l.S-inch ACFoam

II, FlintBoardNote 2 1 per 1.45ft2

BP-AA3, 24-inch

gridBP-AA or SBS-AA SBS-TA -52.5

S-50

Min. 22 ga., type B, Grade33 steel or min. 2,500 psi

structrual concrete

(Optional for Concrete orRecover) Min. 1.5-inch,One or more layers, anycombination, loose laid

Min. 0.25-inch

SECUROCK Gypsum-

Fiber Roof Board

FlintFast #12 (steel only) or#14 HD with FlintFast 3"

Insulation Plates

1 per1.45ft2 APP-TA (Optional) APP-TA APP-TA -60.0

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 23 of 57

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

6™ EDITION (2017)FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

TRINITY ERDTABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVER

SYSTEMTYPEC: MECHANICALLY ATTACHED INSULATION, BONDED ROOFCOVERSystem

No.

Deck

(Note 1)Base Insulation Layer(s)

Top Insulation Layer Roof Cover (Note 14) MDP

(psf)Type Fasteners Attach Base Ply Cap

S-51

Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete

(Optional for Concrete orRecover) Min. 2-inch

ACFoam II, FlintBoard, H-

Shield or ENRGY 3, looselaid.

Min. 0.5-inch

SECUROCKGypsum-

Fiber Roof Board

Note 2 1 per 1.78 ft2 BP-AA, SBS-AA,

SBS-TA or APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-60.0

S-52

Min. 22 ga., type B, Grade

33 steel or min. 2,500 psistructrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. 0.5-inch

SECUROCK Gypsum-Fiber Roof Board

FlintFast #12 (steel only) or#14 HD with FlintFast 3"

Insulation Plates or Trufast #12

(steel only) or HDwith Trufast3" Metal Insulation Plates

1 per 1.45 ft2 BP-AA, SBS-AA,

SBS-TA or APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-82.5

S-53

Min. 22 ga., type B, Grade

33 steel or min. 2,500 psistructrual concrete

(Optional for Concrete orRecover) Min. l.S-inchACFoam II, FlintBoard, H-Shield

Min. 0.5-inch Dens

Deck Prime

Trufast HD with Trufast 3"

Metal Insulation Plates or

FlintFast #14 with FlintFast 3"

Insulation Plates

lper 1.33 ft2 BP-AA, SBS-AA(Optional) BP-AA,SBS-AA

SBS-AA -112.5

S-54

Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. 0.5-inch

SECUROCK Gypsum-Fiber Roof Board

FlintFast #12 (steel only) or#14 HD with FlintFast 3"

Insulation Plates or Trufast #12

(steel only) or HDwith Trufast3" Metal Insulation Plates

1 per 1 ft2 BP-AA, SBS-AA,

SBS-TA or APP-TA

(Optional) BP-AA,SBS-AA, SBS-TAor

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-135.0

S-55

Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete

(Optional for Concrete orRecover) Min. 1.5-inch

ACFoam II, FlintBoard, H-Shield

Min. 0.5-inch

SECUROCK Gypsum-Fiber Roof Board

Trufast HD with Trufast 3"

Metal Insulation Plates or

FlintFast #14 with FlintFast 3"

Insulation Plates

1 per 1.33 ft2 BP-AA, SBS-AA(Optional) BP-AA,SBS-AA

SBS-AA -157.5

S-56

Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete

(Optional for Concrete orRecover) Min. 1.5-inchACFoam II, FlintBoard, H-Shield

Min. 0.5-inch Dens

Deck Prime

Trufast HD with Trufast 3"

Metal Insulation Plates or

FlintFast #14 with FlintFast 3"

Insulation Plates

1 per 1 ft2 BP-AA, SBS-AA(Optional) BP-AA,SBS-AA

SBS-AA -157.5

S-57

Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete

(Optional for Concrete orRecover) Min. 1.5-inch

ACFoam II, FlintBoard, H-Shield |

Min. 0.5-inch

SECUROCK Gypsum-Fiber Roof Board

Trufast HD with Trufast 3"

Metal Insulation Plates or

FlintFast #14 with FlintFast 3"

Insulation Plates

1 per 1 ft2 BP-AA, SBS-AA(Optional) BP-AA,SBS-AA

SBS-AA -172.5

S-58

Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. 0.25-inch

SECUROCK Gypsum-Fiber Roof Board

FlintFast #12 (steel only) or#14 HD with FlintFast 3"

Insulation Plates or Trufast #12

(steel only) or HD with Trufast3" Metal Insulation Plates

1 per 2.7 ft2 SBS-CAl None SBS-CAl -37.5*

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610)651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19

Revision 20: 09/14/2017Appendix 1, Page 24 of 57

TRINITY ERD

TABLE 2B: STEEL ORSTRUCTURAL CONCRETE DECKS-NEWCONSTRUCTION, REROOF (Tear-Off)or RECOVERSYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER

System

No.

Deck

(Note 1)Base Insulation Layer(s)

Top Insulation Layer Roof Cover (Note 14) MDP

(psf)Type Fasteners Attach Base Ply Cap

S-59

Min. 22 ga., type B, Grade33 steel or min. 2,500 psi

structrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. l.S-inch ACFoam

III, FlintBoard Iso Cold,H-Shield CG or

FlintBoard Iso ColdH

FlintFast #12 (steel only) or#14 HD with FlintFast 3"

Insulation Plates or Trufast #12

(steel only) or HDwith Trufast3" Metal Insulation Plates

1 per 2 ft2 SBS-CAl None SBS-CAl -45.0*

S-60

Min. 22 ga., type B, Grade33 steel or min. 2,500 psi

structrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. 3/8-inchSECUROCKGypsum-Fiber Roof Board

FlintFast #12 (steel only) or#14 HD with FlintFast 3"

Insulation Plates or Trufast #12

(steel only) or HDwith Trufast3" Metal Insulation Plates

1 per 2.7 ft2 SBS-CAl None SBS-CAl -45.0*

S-61

Min. 22 ga., type B, Grade33 steel or min. 2,500 psi

structrual concrete

(Optional) One or morelayers, any combination,loose laid

Min. 0.5-inch

SECUROCK Gypsum-

Fiber Roof Board

FlintFast #12 (steel only) or#14 HD with FlintFast 3"

Insulation Plates or Trufast #12

(steel only) or HDwith Trufast3" Metal Insulation Plates

1 per 1.45ft2 SBS-CAl None SBS-CAl -82.5*

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic" Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report352Q.03.04-R20 for FL2533-R19Revision 20:09/14/2017

Appendix 1, Page 25 of 57

TRINITY erdTABLE 2C: STEEL ORSTRUCTURAL CONCRETE DECKS- NEWCONSTRUCTION, REROOF (Tear-Off) or RECOVER

SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHEDBASE SHEET, BONDEDROOFCOVERNote: Insulation optional for Recoveror Concrete Deckappucavons (Note 14)

System

No.

Deck

(Note 1)

Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP

(psf)Type Attach Base Fasteners Attach Ply CapSelf-Adhering Systems:

S-62

Min. 22 ga., type B, Grade

33 steel or min. 2,500 psistructrual concrete

Min. 1.5-inch, One

or more layers, anycombination

Prelim.

AttachedFlintlastic SA NailBase Note 2

9-inch o.c. at min. 2-inch lap and18-inch o.c. in two (2), equallyspaced, staggered center rows

(Optional) SBS-SA

SBS-SA -45.0*

S-63

Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete

Min. 1.5-inch, One

or more layers, anycombination

Prelim.

AttachedFlintlastic SA NailBase Note 2

12-inch o.c. at min. 2-inch lap and12-inch o.c. in two (2), equallyspaced, staggered center rows

(Optional) SBS-SA

SBS-SA -52.5*

S-64

Min. 22 ga., type B, Grade

33 steel or min. 2,500 psi

structrual concrete

Min. 1.5-inch, One

or more layers, anycombination

Prelim.

AttachedFlintlastic SA NailBase Note 2

12-inch o.c. at min. 4-inch lap and12-inch o.c. in two (2), equallyspaced, staggered center rows

(Optional) SBS-SA

SBS-SA -60.0*

S-65

Min. 22 ga., type B, Grade

33 steel or min. 2,500 psistructrual concrete

Min. 1.5-inch, One

or more layers, anycombination

Prelim.

Attached

Flintlastic SA NailBase

(laid parallel to deck

flutes)Note 2

8-inch o.c. at min. 4-inch lap and 8-inch o.c. in two (2), equally spaced,staggered center rows

(Optional) SBS-SA

SBS-SA -82.5*

Conventional Systems:

S-66

Min. 22 ga., type B, Grade

33 steel or min. 2,500 psistructrual concrete

Min. 1.5-inch, One

or more layers, anycombination

Prelim.

Attached

Glasbase; All

Weather/Empire Base;Flexiglas Base; FlintlasticBase 20; Yosemite

Note 2

12-inch o.c. at 4-inch lap and 36-inch o.c. in two (2), equally spaced,staggered center rows

BP-AA, SBS-AA,

SBS-TA or APP-

TA

SBS-AA, SBS-

TA or APP-TA-30.0*

S-67

Min. 22 ga., type B, Grade

33 steel or min. 2,500 psistructrual concrete

Min. 1.5-inch, One

or more layers, anycombination

Prelim.

Attached

Glasbase; All

Weather/Empire Base;Flexiglas Base; FlintlasticBase 20; Yosemite

Note 2

12-inch o.c. at 4-inch lap and 24-inch o.c. in two (2), equally spaced,staggered center rows

BP-AA, SBS-AA,

SBS-TA or APP-

TA

SBS-AA, SBS-

TA or APP-TA-45.0*

S-68

Min. 22 ga., type B, Grade

33 steel or min. 2,500 psistructrual concrete

Min. 1.5-inch, One

or more layers, any

combination

Prelim.

Attached

Poly SMS Base; Ultra PolySMS Base

Note 2

12-inch o.c. at 4-inch lap and 36-inch o.c. in two (2), equally spaced,staggered center rows

BP-AA, SBS-AA,

SBS-TA or APP-

TA

SBS-AA, SBS-

TA or APP-TA-45.0*

S-69

Min. 22 ga., type B, Grade

33 steel or min. 2,500 psistructrual concrete

Min. 1.5-inch, One

or more layers, anycombination

Prelim.

Attached

Poly SMS Base; Ultra PolySMS Base

Note 2

18-inch o.c. at 4-inch lap and 18-inch o.c. in one (1) staggeredcenter row

BP-AA, SBS-AA,

SBS-TA or APP-

TA

SBS-AA, SBS-

TA or APP-TA-45.0*

S-70

Min. 22 ga., type B, Grade

33 steel or min. 2,500 psistructrual concrete

Min. 1.5-inch, One

or more layers, anycombination

Prelim.

Attached

Poly SMS Base; Ultra PolySMS Base

Dekfast IF-2-SBplates with#14 Dekfast

12-inch o.c. within the min. 4-inch

wide, heat-welded side lapSBS-AA, SBS-TA

or APP-TA

SBS-AA, SBS-

TA or APP-TA-45.0*

S-71

Min. 22 ga., type B, Grade

33 steel or min. 2,500 psistructrual concrete

Min. 1.5-inch, One

or more layers, anycombination

Prelim.

Attached

Glasbase; Flexiglas Base;Flintlastic Base 20; All

Weather / Empire Base;Poly SMS Base; Yosemite

Note 2

12-inch o.c. at 3-inch lap and 12-inch o.c. in two (2), equally spaced,staggered center rows

BP-AA, SBS-AA,

SBS-TA or APP-

TA

SBS-AA, SBS-

TA or APP-TA-52.5

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19

Revision 20: 09/14/2017

Appendix 1, Page 26 of 57

TRINITY ERD

TABLE 2C: STEEL ORSTRUCTURAL CONCRETE DECKS- NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVERSYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER

Note: Insulationoptional for Recoveror ConcreteDeckappucations(Note 14)

System

No.

Deck

(Note 1)

Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP

(psf)Type Attach Base Fasteners Attach Ply Cap

S-72

Min. 22 ga., type B, 40 ksisteel or min. 2,500 psi

structrual concrete

Min. 2-inch, One or

more layers, any

combination

Prelim.

AttachedUltra Poly SMS Base

Trufast 2" Barbed Metal

Seam Plates with Trufast

#15EHD(sree/on/y;orTrufast #14 HD (concreteonly)

12-inch o.c. within the min. 4-inch

wide, heat-welded side lap

(Optional) SBS-TA or APP-TA

SBS-TA or

APP-TA-52.5

S-73

Min. 22 ga., type B, Grade80 steel or min. 2,500 psi

structrual concrete

Min. 1.5-inch, One

or more layers, anycombination

Prelim.

AttachedUltra Poly SMS Base

Trufast 2.4" Barbed Metal

Seam Plates with Trufast

#15EHDfsree/on/WorTrufast #14 HD (concrete

only)

12-inch o.c. within the min. 4-inch

wide, heat-welded side lap

(Optional) SBS-TA or APP-TA

SBS-TA or

APP-TA-60.0

S-74

Min. 22 ga., type B, 40 ksisteel or min. 2,500 psi

structrual concrete

Min. 2-inch, One or

more layers, anycombination

Prelim.

AttachedUltra Poly SMS Base

Trufast 2.4" Scoop Seam

Plates with Trufast #15

EHD (steel only) or Trufast#14 HD(concrete only)

12-inch o.c. within the min. 4-inch

wide, heat-welded side lap

(Optional) SBS-TA or APP-TA

SBS-TA or

APP-TA-67.5

S-75

Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete

Min. 1.5-inch, One

or more layers, any

combination

Prelim.

AttachedGlasbase; Yosemite

OMG Flat Bottom Plates

with OMG #14 HD

(Accutrac)

6-inch o.c. at 4-inch lap and 6-inch

o.c. in two (2), equally spaced,staggered center rows

BP-AA, SBS-AA,

SBS-TA or APP-

TA

SBS-AA, SBS-

TA or APP-TA-67.5

S-76

Min. 22 ga., type B, Grade33 steel or min. 2,500 psi

structrual concrete

Min. l.S-inch, One

or more layers, anycombination

Prelim.

Attached

Flexiglas Base; FlintlasticBase 20; Yosemite

Note 2

6-inch o.c. at 4-inch lap and 6-incho.c. in two (2), equally spaced,staggered center rows

BP-AA, SBS-AA,

SBS-TA or APP-

TA

SBS-AA, SBS-

TA or APP-TA-67.5

S-77

Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete

Min. 1.5-inch, One

or more layers, anycombination

Prelim.

Attach

Glasbase; Flexiglas;Flintlastic Base 20; All

Weather / Empire Base;Poly SMS Base; Ultra PolySMS Base; Yosemite

Flintfast 3 in. Insulation

Plates with FlintFast #14;

Trufast 3" Metal Insulation

Plates with Trufast HD

6-inch o.c. at 4-inch lap and 6-inch

o.c. at three (3) equally spaced,staggered center rows

(Optional) BP-

AA, SBS-AA or

SBS-TA

SBS-AA or

SBS-TA-97.5

S-78

Min. 22 ga., type B, 40 ksisteel or min. 2,500 psi

structrual concrete

Min. 2-inch, One or

more layers, anycombination

Prelim.

AttachedUltra Poly SMS Base

Trufast 2.4" Scoop SeamPlates with Trufast #15

EHD(steel only) or Trufast#14 HD (concrete only)

6-inch o.c. within the min. 4-inch

wide, heat-welded side lap

(Optional) SBS-TA or APP-TA

SBS-TA or

APP-TA-112.5

S-79

Min. 22 ga., type B, Grade80 steel or min. 2,500 psi

structrual concrete

Min. 1.5-inch, One

or more layers, any

combination

Prelim.

Attached

Poly SMS Base; Ultra PolySMS Base

Note 2

12-inch o.c. at 4-inch lap and 12-inch o.c. in two (2), equally spaced,staggered center rows

SBS-TA or APP-

TA

SBS-TA or

APP-TA-112.5

S-80

Min. 22 ga., type B, Grade80 steel or min. 2,500 psi

structrual concrete

Min. 1.5-inch, One

or more layers, any

combination

Prelim.

Attached

Poly SMS Base; Ultra PolySMS Base

Note 2

12-inch o.c. at 4-inch lap and 12-inch o.c. in two (2), equally spaced,staggered center rows

SBS-AASBS-AA or

SBS-TA-120.0

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

6™ EDITION (2017)FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 27 of 57

TRINITY ERD

TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVERSYSTEM TYPE D: INSUUTED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER

Note:Insulation optional for Recover or Concrete Deckappucations (Note14)System

No.

Deck

(Note 1)Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 14) MDP

(psf)Type Attach Base Fasteners Attach Ply Cap

S-81

Min. 22 ga., type B, 40 ksi

steel or min. 2,500 psistructrual concrete

Min. 2-inch, One or

more layers, anycombination

Prelim.

AttachedUltra Poly SMS Base

Trufast 2.4" Scoop SeamPlates with Trufast #15

EHD(steel only) or Trufast#14 HD(concrete only)

6-inch o.c. within the min. 4-inch

wide, heat-welded side laps and 6-inch o.c. in one (1) center row,stripped-in with 6-inch side stripsof torch-applied PolySMSBase orUltra Poly SMS Base.

(Optional) SBS-TA or APP-TA

SBS-TA or

APP-TA-165.0

S-82

Min. 22 ga., type B, Grade33 steel or min. 2,500 psistructrual concrete

Min. l.S-inch, One

or more layers, anycombination

Prelim.

Attached

Glasbase; All

Weather/Empire Base;Flexiglas Base; FlintlasticBase 20

Note 2

6-inch o.c. at 4-inch lap and 12-inch o.c. in two (2), equally spaced,staggered center rows

SBS-CAl SBS-CAl -45.0*

S-83

Min. 22 ga., type B, Grade40 steel or min. 2,500 psistructrual concrete

Min. 1-inch, One or

more layers, anycombination

Loose-la id

Glasbase; Flexiglas Base;Flintlastic Base 20; AllWeather/ Empire Base;Yosemite Venting Base;Flintlastic Poly SMS Base;Flintlastic Ultra Poly SMSBase

FlintFast #14 HD with

FlintFast 3" Insulation

Plates or Trufast HD with

Trufast 3" Metal Insulation

Plates

6-inch o.c. at 4-inch lap and 12-inch o.c. in three (3), equallyspaced, staggered center rows

(Optional) SBS-CAl

SBS-CAl -75.0

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeedFlintlastic* Modified Bitumen Roof Systems; (610)651-5847

Evaluation Report 3520.O3.O4-R20 for FL2533-R19

Revision 20: 09/14/2017Appendix 1, Page 28 of 57

TRINITY ERD

TABLE3A: STRUCTURALCONCRETE DECKS-NEW CONSTRUCTION or REROOF(Tear-Off)

SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOF COVER

Sys.

No.

Deck

(Note 1)Primer

Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP

(psf)Type Attach Type Attach Base Ply Cap

Self-Adhering Systems:

C-l.Structural

concrete

FlintPrime

(ASTM D41)

Min. 1.5-inch ACFoam II, FlintBoard,ENRGY 3 or H-Shield

HAMin. 0.25-inch SECUROCKGypsum-

Fiber Roof BoardHA SBS-SA (Optional) SBS-SA SBS-SA -172.5

C-2.Structural

concrete

FlintPrime

(ASTM D41)

Min. 1.5-inch ACFoam II, FlintBoard,

ENRGY 3 or Multi-Max FA3HA

Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA

HA SBS-SA (Optional) SBS-SA SBS-SA -192.5

C-3.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoard,ENRGY 3 or Multi-Max FA3

A-PDMin. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA

A-PD SBS-SA (Optional) SBS-SA SBS-SA -105.0

C-4.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoard,ENRGY 3 or H-Shield

A-PDMin. 0.25-inch SECUROCK Gypsum-

Fiber Roof BoardA-PD SBS-SA (Optional) SBS-SA SBS-SA -172.5

C-5.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoard,

ENRGY 3 or Multi-Max FA3

A-PD

6-inch o.c.

Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA

A-PD

6-inch o.c.SBS-SA (Optional) SBS-SA SBS-SA -192.5

C-6.Structural

concrete

(Optional)FlintPrime

(ASTM D41)

Min. 1.5-inch Multi-Max FA D-ISMin. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA

D-IS SBS-SA (Optional) SBS-SA SBS-SA -67.5

C-7.Structural

concrete

(Optional)FlintPrime

(ASTMD41)Min. l.S-inch ENRGY 3 D-IS

Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA

D-IS SBS-SA (Optional) SBS-SA SBS-SA -112.5

C-8.Structural

concrete

(Optional)FlintPrime

(ASTM D41)

Min. 1.5-inch ACFoam II or FlintBoard D-ISMin. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA

D-IS SBS-SA (Optional) SBS-SA SBS-SA -120.0

C-9.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoard,

ENRGY 3 or H-ShieldD-IS

Min. 0.25-inch SECUROCK Gypsum-

Fiber Roof BoardD-IS SBS-SA (Optional) SBS-SA SBS-SA -172.5

C-10.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoard,

ENRGY 3 or H-Shield

M-OSFA or

M-PGl

Min. 0.25-inch SECUROCK Gypsum-

Fiber Roof Board

M-OSFA or

M-PGlSBS-SA (Optional) SBS-SA SBS-SA -172.5

C-ll.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoard,

ENRGY 3 or Multi-Max FA

M-OSFA or

M-PGl

Min. 0.25-inch Dens Deck primed

with FlintPrime or FlintPrime SA

M-OSFA or

M-PGlSBS-SA (Optional) SBS-SA SBS-SA -192.5

C-12.Structural

concrete

FlintPrime

(ASTM D41)

Min. 1.5-inch ACFoam II, FlintBoard ISOor ENRGY 3

OB500Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA

OB500 SBS-SA (Optional) SBS-SA SBS-SA -120.0

C-13.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoard ISO

or ENRGY 3OB500

Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA

OB500 SBS-SA (Optional) SBS-SA SBS-SA -150.0

C-14.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoard,ENRGY 3 or H-Shield

OB500Min. 0.25-inch SECUROCKGypsum-

Fiber Roof BoardOB500 SBS-SA (Optional) SBS-SA SBS-SA -172.5

C-15.Structural

concreteNone

Min. 1.0-inch ISO 95+ GL, H-Shield, H-

Shield CG, ENRGY 3 or min. 1.3-inchACFoam III, Min. 1.5-inch Multi-MaxFA3 or Ultra-Max

CR-20Min. 0.25-inch SECUROCKGypsum-

Fiber Roof BoardCR-20 SBS-SA (Optional) SBS-SA SBS-SA -172.5

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

6thEDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 29 of 57

TRINITY ERDTABLE 3A: STRUCTURAL CONCRETE DECKS- NEW CONSTRUCTION or REROOF (Tear-Off)

SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOF COVER

Sys.

No.

Deck

(Note 1)Primer

Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP

(psf)Type Attach Type Attach Base Ply Cap

C-16.Structural

concreteNone

Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY3 or min. 1.3-inch

ACFoam III, Min. 1.5-inch Multi-MaxFA3 or Ultra-Max

CR-20Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA

CR-20 SBS-SA (Optional) SBS-SA SBS-SA -192.5

Hybrid Systems:

C-17.Structural

concrete

FlintPrime

(ASTM D41)Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH

HA(Optional) Additional layer(s) baseinsulation

HA

Flintlastic

Ultra Glass

SA

(Optional) SBS-AA,SBS-TA, APP-TA

SBS-AA, SBS-

TA, APP-TA-322.5

C-18.Structural

concrete

FlintPrime

(ASTM D41)Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH

HA(Optional) Additional layer(s) baseinsulation

HA

Black

Diamond

Base Sheet

(Optional) SBS-AA,SBS-TA, APP-TA

SBS-AA, SBS-

TA, APP-TA-375.0

C-19.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH

A-PD(Optional) Additional layer(s) baseinsulation

A-PD SBS-SA-H(Optional) SBS-AA,SBS-TA, APP-TA

SBS-AA, SBS-

TA, APP-TA-180.0

C-20.Structural

concreteNone

Min. l.S-inch ACFoam II, FlintBoard

ISO, H-Shield, FlintBoard ISOHA-PD

Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

A-PD SBS-SA-H(Optional) SBS-AA,SBS-TA, APP-TA

SBS-AA, SBS-

TA, APP-TA-117.5

C-21.Structural

concreteNone

Min. l.S-inch ACFoam II, FlintBoard

ISO, H-Shield, FlintBoard ISOHA-PD, 6-incho.c.

Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

A-PD, 6-inch

o.c.SBS-SA-H

(Optional) SBS-AA,SBS-TA, APP-TA

SBS-AA, SBS-

TA, APP-TA-217.5

C-22.Structural

concreteNone

Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

A-PD, 6-inch

o.c.None N/A SBS-SA-H

(Optional) SBS-AA,SBS-TA, APP-TA

SBS-AA, SBS-

TA, APP-TA-195.0

C-23.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH

D-IS(Optional) Additional layer(s) baseinsulation

D-IS SBS-SA-H(Optional) SBS-AA,SBS-TA, APP-TA

SBS-AA, SBS-

TA, APP-TA-135.0

C-24.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoard

ISO, H-Shield, FlintBoard ISOHD-IS

Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

D-IS SBS-SA-H(Optional) SBS-AA,SBS-TA, APP-TA

SBS-AA, SBS-

TA, APP-TA-217.5

C-2S.Structural

concreteNone

Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

D-IS None N/A SBS-SA-H(Optional) SBS-AA,SBS-TA, APP-TA

SBS-AA, SBS-

TA, APP-TA-195.0

C-26.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH M-OSFA

(Optional) Additional layer(s) baseinsulation

M-OSFA SBS-SA-H(Optional) SBS-AA,SBS-TA, APP-TA

SBS-AA, SBS-

TA, APP-TA-232.5

C-27.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH

M-OSFAMin. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

M-OSFA SBS-SA-H(Optional) SBS-AA,SBS-TA, APP-TA

SBS-AA, SBS-

TA, APP-TA-217.5

C-28.Structural

concreteNone

Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

M-OSFA None N/A SBS-SA-H(Optional) SBS-AA,SBS-TA, APP-TA

SBS-AA, SBS-

TA, APP-TA-195.0

C-29.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH

M-PGl(Optional) Additional layer(s) baseinsulation

M-PGl SBS-SA-H(Optional) 5BS-AA,SBS-TA, APP-TA

SBS-AA, SBS-

TA, APP-TA-270.0

C-30.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH M-PGl

Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

M-PGl SBS-SA-H(Optional) SBS-AA,SBS-TA, APP-TA

SBS-AA, SBS-

TA, APP-TA-217.5

C-31.Structural

concreteNone

Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

M-PGl None N/A SBS-SA-H(Optional) SBS-AA,SBS-TA, APP-TA

SBS-AA, SBS-

TA, APP-TA-195.0

Exterior Research and Design, LLC. d/b/a Trinity| ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 30 of 57

TRINITY ERDTABLE3A: STRUCTURALCONCRETE DECKS- NEW CONSTRUCTIONor REROOF(Tear-Off)

SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOF COVER

Sys.

No.

Deck

(Note 1)Primer

Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP

(psf)Type Attach Type Attach Base Ply Cap

C-32.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH

OB500(Optional) Additional layer(s) baseinsulation

OB500 SBS-SA-H(Optional) SBS-AA,SBS-TA, APP-TA

SBS-AA, SBS-

TA, APP-TA-135.0

C-33.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH

OB500Min. 0.25-inch SECUROCKGypsum-

Fiber Roof BoardOB500 SBS-SA-H

(Optional) SBS-AA,SBS-TA, APP-TA

SBS-AA, SBS-

TA, APP-TA-217.5

C-34.Structural

concreteNone

Min. 0.25-inch SECUROCKGypsum-

Fiber Roof BoardOB500 None N/A SBS-SA-H

(Optional) SBS-AA,SBS-TA, APP-TA

SBS-AA, SBS-

TA, APP-TA-195.0

C-35.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH

CR-20(Optional) Additional layer(s) baseinsulation

CR-20 SBS-SA-H(Optional) SBS-AA,SBS-TA, APP-TA

SBS-AA, SBS-

TA, APP-TA-270.0

C-36.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoard

ISO, H-Shield, FlintBoard ISOHCR-20

Min. 0.25-inch SECUROCK Gypsum-

Fiber Roof BoardCR-20 SBS-SA-H

(Optional) SBS-AA,SBS-TA, APP-TA

SBS-AA, SBS-

TA, APP-TA-217.5

C-37.Structural

concreteNone

Min. 0.25-inch SECUROCKGypsum-

Fiber Roof BoardCR-20 None N/A SBS-SA-H

(Optional) SBS-AA,SBS-TA, APP-TA

SBS-AA, SBS-

TA, APP-TA-195.0

Conventional Systems:

C-38.Structural

concrete

FlintPrime

(ASTM D41)

Min. 1.5-inch ACFoam II, ENRGY 3, H-

Shield, FlintBoard ISOHA

(Optional) Additional layer(s) ofbase insulation

HABP-AA3, 24-

inch grid

(Optional) BP-AA,SBS-AA

SBS-AA -37.5

C-39.Structural

concrete

FlintPrime

(ASTM D41)Min. 1.5-inch ACFoam II or FlintBoard

ISO.HA

Min. 0.25-inch Dens Deck, Dens

Deck PrimeHA SBS-TA (Optional) SBS-TA SBS-TA -180.0

C-40.Structural

concrete

FlintPrime

(ASTM D41)

(Optional) Min. 1.5-inch ACFoam IIorFlintBoard ISO.

HAMin. 0.25-inch SECUROCK Gypsum-

Fiber Roof BoardHA

BP-AA, SBS-

AA, SBS-TA

or APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-180.0

C-41.Structural

concrete

FlintPrime

(ASTM D41)

(Optional) Min. 2-inch ACFoam II,FlintBoard ISO, ENRGY 3 or H-Shield

HAMin. 0.25-inch SECUROCKGypsum-

Fiber Roof BoardHA

BP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-225.0

C-42.Structural

concrete

FlintPrime

(ASTM D41)

(Optional) Min. 1.5-inch ACFoam II,FlintBoard ISO, H-Shield, FlintBoard

ISO„

HAMin. 0.25-inch SECUROCKGypsum-

Fiber Roof BoardHA APP-TA (Optional) APP-TA APP-TA -252.5

C-43.Structural

concrete

FlintPrime

(ASTM D41)

Min. l.S-inch ACFoam II, FlintBoardISO, ENRGY 3 or H-Shield

HAMin. 0.5-inch Structodek High

Density FiberboardHA

BP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-227.0

C-44.Structural

concrete

FlintPrime

(ASTM D41)

(Optional) Min. 2-inch ACFoam II,FlintBoard ISO, ENRGY3 or H-Shield

HAMin. 0.25-inch SECUROCKGypsum-

Fiber Roof BoardHA

SBS-TA or

APP-TA

(Optional) SBS-TAor APP-TA

SBS-TA or

APP-TA-232.5

C-45.Structural

concrete

FlintPrime

(ASTM D41)

Min. l.S-inch ACFoam II, FlintBoard

ISO, ENRGY3 or H-ShieldHA Min. 0.25-inch Dens Deck HA

BP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-240.0

C-46.Structural

concrete

FlintPrime

(ASTM D41)

Min. 1.5-inch ACFoam II or FlintBoard

ISOHA

Min. 0.75-inch FescoBoard

(homogeneous)HA

BP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-412.0

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20:09/14/2017

Appendix 1, Page 31 of 57

TRINITY ERDTABLE3A: STRUCTURAL CONCRETE DECKS- NEW CONSTRUCTION OR REROOF(Tear-Off)

SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOF COVER

Sys.

No.

Deck

(Note 1)Primer

Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP

(psf)Type Attach Type Attach Base Ply Cap

C-47.Structural

concrete

FlintPrime

(ASTM D41)Min. 1.5-inch ACFoam II or FlintBoard

ISOHA

Min. 0.5-inch DuraBoard

(homogeneous)HA

BP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-430.0

C-48.Structural

concrete

FlintPrime

(ASTM D41)

0.5-inch Structodek High DensityFiberboard or min. 0.75-inch Fesco

Board (homogeneous)HA None N/A BP-AA

(Optional) BP-AAor

SBS-AASBS-AA -437.5

C-49.Structural

concrete

FlintPrime

(ASTM D41)0.25-inch Dens Deck, Dens Deck Prime

or SECUROCKGypsum-Fiber Roof BoardHA None N/A SBS-TA

(Optional) SBS-AAor SBS-TA

SBS-AA or

SBS-TA-302.5

C-50.Structural

concrete

FlintPrime

(ASTM D41)Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

HA None N/A

Flintlastic

Ultra PolySMS Base,

torched

(Optional) FlintlasticUltra Poly SMSBase, torched

SBS-TA -487.5

C-51.Structural

concrete

FlintPrime

(ASTM D41)0.25-inch Dens Deck, Dens Deck Prime

or SECUROCK Gypsum-Fiber Roof BoardHA None N/A BP-AA

(Optional) BP-AAorSBS-AA

SBS-AA -537.5

C-52.Structural

concreteNone

Min. l.S-inch ACFoam II, FlintBoard

ISO, ENRGY 3 or H-ShieldA-PD

Min. 0.5-inch Structodek HighDensity Fiberboard or Min. 0.25-inch Dens Deck

A-PDBP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-105.0

C-53.Structural

concreteNone

Min. l.S-inch ACFoam II, FlintBoard

ISO, ENRGY 3 or H-Shield

A-PD

6-inch o.c.

Min. 0.5-inch Structodek HighDensity Fiberboard or Min. 0.25-inch Dens Deck

A-PD

6-inch o.c.

BP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-217.5

C-54.Structural

concreteNone

Min. l.S-inch ACFoam II, FlintBoard

ISO, H-Shield, FlintBoard ISOHA-PD

Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

A-PD

BP-AA, SBS-

AA, SBS-TA

or APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-117.5

C-55.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoard

ISO, H-Shield, FlintBoard ISO„

A-PD, 6-inch

o.c.

Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

A-PD, 6-inch

o.c.

BP-AA, SBS-AA, SBS-TA

or APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-217.5

C-56.Structural

concreteNone

0.5-inch Structodek High DensityFiberboard

A-PD, 6-inch

o.c.None N/A

BP-AA, SBS-

AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-195.0

C-57.Structural

concreteNone

Min. 0.25-inch Dens Deck, Dens Deck

Prime or SECUROCK Gypsum-Fiber RoofBoard

A-PD, 6-inch

o.c.None N/A

BP-AA, SBS-

AA, SBS-TA

or APP-TA

(Optional) BP-AA,

SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-195.0

C-58.Structural

concreteNone

Min. 1.5-inch ACFoam II or FlintBoard

ISO.D-IS Min. 0.25-inch Dens Deck D-IS SBS-TA (Optional) SBS-TA SBS-TA -112.5

C-59.Structural

concreteNone

Min. l.S-inch ACFoam II, FlintBoard

ISO, H-Shield, FlintBoard ISOHD-IS Min. 0.25-inch Dens Deck Prime D-IS

BP-AA, SBS-

AA

(Optional) BP-AA,SBS-AA or SBS-TA

SBS-AA or

SBS-TA-297.5

C-60.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoard

ISO, H-Shield, FlintBoard ISOHD-IS Min. 0.25-inch Dens Deck Prime D-IS SBS-TA (Optional) SBS-TA SBS-TA -302.5

Exterior Research and Design, LLC.Certificate of Authorization #9503

Prepared by: Robert Nieminen, PE

d/b/a Trinity | ERD

59166

6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19

Revision 20: 09/14/2017Appendix 1, Page 32 of 57

TRINITY ERD

TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (Tear-Off)SYSTEM TYPE A-l: BONDEDINSULATION, BONDEDROOFCOVER

Sys.

No.

Deck

(Notel)Primer

Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP

(psf)Type Attach Type Attach Base Ply Cap

C-61.Structural

concreteNone

Min. 2-inch ACFoam II, FlintBoard ISO,ENRGY 3 or H-Shield

D-ISMin. 0.25-inch SECUROCKGypsum-

Fiber Roof BoardD-IS

BP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-225.0

C-62.Structural

concreteNone

Min. 2-inch ACFoam II, FlintBoard ISO,ENRGY 3 or H-Shield

D-ISMin. 0.25-inch SECUROCK Gypsum-

Fiber Roof BoardD-IS

SBS-TA or

APP-TA

(Optional) SBS-TAor APP-TA

SBS-TA or

APP-TA-232.5

C-63.Structural

concreteNone

Min. l.S-inch ACFoam II, FlintBoardISO,H-Shield, FlintBoard ISOH

D-ISMin. 0.25-inch SECUROCKGypsum-

Fiber Roof BoardD-IS APP-TA (Optional) APP-TA APP-TA -252.5

C-64.Structural

concreteNone

Min. l.S-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH

D-ISMin. 0.2S-inch SECUROCKGypsum-

Fiber Roof BoardD-IS

BP-AA, SBS-

AA or SBS-

TA

(Optional) BP-AA,SBS-AA or SBS-TA

SBS-AA or

SBS-TA-297.5

C-65.Structural

concreteNone

0.5-inch Structodek High Density

FiberboardD-IS None N/A

BP-AA, SBS-

AA

(Optional) BP-AA,SBS-AA, SBS-TAor

APP-TA

SBS-AA, SBS-

TA or APP-TA-195.0

C-66.Structural

concreteNone

Min. 0.25-inch SECUROCKGypsum-

Fiber Roof BoardD-IS None N/A

BP-AA, SBS-

AA, SBS-TA

or APP-TA

(Optional) BP-AA,SBS-AA, SBS-TAor

APP-TA

SBS-AA, SBS-

TA or APP-TA-195.0

C-67.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoardISO,ENRGY 3 or H-Shield

M-OSFAMin. 0.5-inch Structodek High

Density FiberboardM-OSFA

BP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TAor

APP-TA

SBS-AA, SBS-

TA or APP-TA-127.5

C-68.Structural

concreteNone

Min. l.S-inch ACFoam II, FlintBoard

ISO,ENRGY 3 or H-ShieldM-PGl

Min. 0.5-inch Structodek High

Density FiberboardM-PGl

BP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-180.0

C-69.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoardISO, ENRGY 3 or H-Shield

M-OSFA Min. 0.25-inch Dens Deck M-OSFABP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-232.5

C-70.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoardISO, ENRGY 3 or H-Shield

M-PGl Min. 0.25-inch Dens Deck M-PGlBP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-240.0

C-71.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoardISO,H-Shield, FlintBoard ISOH

M-PGl Min. 0.25-inch Dens Deck Prime M-PGlBP-AA, SBS-

AA

(Optional) BP-AA,SBS-AA or SBS-TA

SBS-AA or

SBS-TA-297.5

C-72.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoardISO,H-Shield, FlintBoard ISOH

M-PGl Min. 0.25-inch Dens Deck Prime M-PGl SBS-TA (Optional) SBS-TA SBS-TA -302.5

C-73.Structural

concreteNone

Min. 2-inch ACFoam II, FlintBoard ISO,ENRGY 3 or H-Shield

M-OSFA or

M-PGl

Min. 0.25-inch SECUROCK Gypsum-

Fiber Roof Board

M-OSFA or

M-PGl

BP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-225.0

C-74.Structural

concreteNone

Min. 2-inch ACFoam II, FlintBoard ISO,ENRGY 3 or H-Shield

M-OSFA or

M-PGl

Min. 0.25-inch SECUROCK Gypsum-

Fiber Roof Board

M-OSFA or

M-PGl

SBS-TA or

APP-TA

(Optional) SBS-TAor APP-TA

SBS-TA or

APP-TA-232.5

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic" Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 33 of 57

TRINITY ERDTABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (Tear-Off)

SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOFCOVER

Sys.

No.

Deck

(Note 1)Primer

Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP

(psf)Type Attach Type Attach Base Ply Cap

C-75.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH

M-OSFA or

M-PGl

Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

M-OSFA or

M-PGlAPP-TA (Optional) APP-TA APP-TA -252.5

C-76.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoardISO, H-Shield, FlintBoard ISOH

M-OSFA or

M-PGl

Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

M-OSFA or

M-PGl

BP-AA, SBS-

AA or SBS-

TA

(Optional) BP-AA,SBS-AA or SBS-TA

SBS-AA or

SBS-TA-297.5

C-77.Structural

concreteNone

0.5-inch Structodek High DensityFiberboard

M-PGl None N/ABP-AA, SBS-

AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-195.0

C-78.Structural

concreteNone

Min. 0.25-inch Dens Deck Prime or

SECUROCK Gypsum-Fiber Roof Board M-PGl None N/ABP-AA, SBS-

AA, SBS-TA

or APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-195.0

C-79.Structural

concreteNone

Min. l.S-inch ACFoam II, FlintBoard

ISO, ENRGY 3 or H-ShieldOB500

Min. 0.5-inch Structodek HighDensity Fiberboard

OB500BP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-120.0

C-80.Structural

concreteNone

Min. 1.5-inch ACFoam II or FlintBoard

ISO.OB500

Min. 0.25-inch Dens Deck or Dens

Deck PrimeOB500

BP-AA, SBS-

AA, SBS-TA

or APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-150.0

C-81.Structural

concreteNone

Min. l.S-inch ACFoam II, FlintBoard

ISO, H-Shield, FlintBoard ISOHOB500 Min. 0.2S-inch Dens Deck Prime OB500

BP-AA, SBS-

AA or SBS-

TA

(Optional) BP-AA,SBS-AA or SBS-TA

SBS-AA or

SBS-TA-297.5

C-82.Structural

concreteNone

Min. 2-inch ACFoam II, FlintBoard ISO,ENRGY 3 or H-Shield

OB500Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

OB500BP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-225.0

C-83.Structural

concreteNone

Min. 2-inch ACFoam II,FlintBoard ISO,ENRGY 3 or H-Shield

OB500Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

OB500SBS-TA or

APP-TA

(Optional) SBS-TAor APP-TA

SBS-TA or

APP-TA-232.5

C-84.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoard

ISO, H-Shield, FlintBoard ISOHOB500

Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

OB500 APP-TA (Optional) APP-TA APP-TA -252.5

C-85.Structural

concreteNone

Min. 1.5-inch ACFoam II, FlintBoard

ISO, H-Shield, FlintBoard ISOHOB500

Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

OB500

BP-AA, SBS-

AA or SBS-

TA

(Optional) BP-AA,SBS-AA or SBS-TA

SBS-AA or

SBS-TA-297.5

C-86.Structural

concreteNone

0.5-inch Structodek High DensityFiberboard

OB500 None N/ABP-AA, SBS-

AA

(Optional) BP-AA,SBS-AA, SBS-TA orAPP-TA

SBS-AA, SBS-

TA or APP-TA-195.0

C-87.Structural

concreteNone

Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

OB500 None N/ABP-AA, SBS-

AA, SBS-TA

or APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-195.0

Exterior Research and Design, LLC. d/b/a Trinity| ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 34 of 57

TRINITY ERD

TABLE 3A: STRUCTURAL CONCRETE DECKS- NEW CONSTRUCTION OR REROOF (Tear-Off)SYSTEMTYPEA-l: BONDED INSULATION, BONDED ROOFCOVER

Sys.

No.

Deck

(Note l)Primer

Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP

(psf)Type Attach Type Attach Base Ply Cap

C-88.Structural

concreteNone

Min. 1.0-inch ISO 95+ GL, H-Shield, H-

Shield CG, ENRGY 3 or min. 1.3-inchACFoam III, Min. 1.5-inch Multi-Max

FA3 or Ultra-Max

CR-20

Min. 0.5-inch Structodek HighDensity Fiberboardor DuraBoard(homogeneous) or min. l.S-inchFescoBoard (laminated)

CR-20BP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-180.0

C-89.Structural

concreteNone

Min. 1.0-inch ISO 95+ GL, H-Shield, H-

Shield CG, ENRGY3 or min. 1.3-inchACFoam III, Min. 1.5-inch Multi-MaxFA3 or Ultra-

CR-20Min. 0.25-inch SECUROCK Gypsum-

Fiber Roof BoardCR-20

BP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SB5-AA, SBS-

TA or APP-TA-225.0

C-90.Structural

concreteNone

Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG, ENRGY 3 or min. 1.3-inchACFoam III, Min. 1.5-inch Multi-MaxFA3 or Ultra-Max

CR-20Min. 0.25-inch SECUROCK Gypsum-

Fiber Roof BoardCR-20

SBS-TA or

APP-TA

(Optional) SBS-TAor APP-TA

SBS-TA or

APP-TA-232.5

C-91.Structural

concreteNone

Min. 1.0-inch ISO 95+ GL, H-Shield, H-

Shield CG, ENRGY 3 or min. 1.3-inchACFoam III, Min. l.S-inch Multi-Max

FA3 or Ultra-Max

CR-20 Min. 0.25-inch Dens Deck CR-20BP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-240.0

C-92.Structural

concreteNone

0.5-inch Structodek High Density

FiberboardCR-20 None N/A

BP-AA, SBS-

AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-195.0

C-93.Structural

concreteNone

Min. 0.25-inch SECUROCK Gypsum-

Fiber Roof BoardCR-20 None N/A

BP-AA, SBS-

AA, SBS-TA

or APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-195.0

COLD-APPlied Systems:

C-94.Structural

concreteNone

(Optional) Min. 0.5-inch ACFoam II,FlintBoard ISO, H-Shield, FlintBoardiso„

OB500 or

CR-20

Min. 1.5-inch ACFoam III,

FlintBoard Iso Cold, H-Shield CG or

FlintBoard Iso ColdH

OB500 or

CR-20SBS-CAl None SBS-CAl -82.5

C-95.Structural

concreteNone

Min. 0.5-inch ACFoam II, FlintBoard

ISO, H-Shield, FlintBoard ISOH

A-PD, D-IS,

M-OSFA, M-

PG1, OB500or CR-20

Min. 0.25-inch SECUROCK Gypsum-

Fiber Roof Board

A-PD, D-IS,

M-OSFA, M-

PG1, OB500

or CR-20

SBS-CAl None SBS-CAl -105.0

System

No.

Deck

(Note 1)

Cold-Applied Systems:

Primer / Temp Roof

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

TABLE 3B: STRUCTURAL CONCRETE DECKS- NEW CONSTRUCTION OR REROOF (Tear-Off)SYSTEM TYPE A-3:BONDED TEMPROOF, BONDED INSULATION, BONDED ROOF COVER

Base Insulation Layer Top Insulation Layer

Type Attach Type Attach

6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Base

Roof Cover (Note 14)

Ply CapMDP (psf)

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page35 of 57

TRINITY ERDTABLE 3B: STRUCTURAL CONCRETE DECKS - NEWCONSTRUCTION OR REROOF (Tear-Off)SYSTEMTYPE A-3: BONDED TEMP ROOF,BONDED INSULATION, BONDED ROOFCOVER

System

No.

Deck

(Note 1)Primer / Temp Roof

Base Insulation Layer Top Insulation Layer Roof Cover (Note 14)MDP (psf)Type Attach Type Attach Base Ply Cap

C-96.Structural

concrete

FlintPrime

(ASTMD41)

Flintlastic SA

PlyBase, self-adhered

(Optional) Min. 0.5-inchACFoam II, FlintBoard

ISO, H-Shield, FlintBoardiso„

OB500

Min. 1.5-inch ACFoam III,

FlintBoard Iso Cold, H-Shield

CG or FlintBoard Iso ColdHOB500 SBS-CAl None SBS-CAl -82.5

C-97.Structural

concrete

FlintPrime

(ASTMD41)

Flintlastic SA

PlyBase, self-adhered

Min. 0.5-inch ACFoam II,FlintBoard ISO, H-Shield,FlintBoard ISOH

OB500Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof BoardOB500 SBS-CAl None SBS-CAl -82.5

Exterior Research and Design, LLC. d/b/a Trinity| ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 36 of 57

TRINITY ERDTABLE3C: STRUCTURALCONCRETE DECKS- NEW CONSTRUCTIONor REROOF(Tear-Off)

SYSTEM TYPE F:NON-INSULATED, BONDED ROOF COVER

System

No.

Deck

(Note 1)Primer

Roof Cover (Note 14)MDP (psf)

Base Ply Cap

Self-Adhering Systems:

C-98. | Structural concrete FlintPrime SA SBS-SA (Optional) SBS-SA SBS-SA -555.0

C-99. Structural concrete FlintPrime (ASTM D41) SBS-SA (Optional) SBS-SA SBS-SA -630.0

Hybrid Systems:

C-100. Structural concrete FlintPrime SA Flintlastic Ultra Glass SA (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5

C-101. Structural concrete FlintPrime (ASTM D41) Flintlastic Ultra Glass SA (Optional) SBS-AA SBS-AA -135.0

C-102. Structural concrete FlintPrime (ASTM D41) Black Diamond Base Sheet (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -150.0

C-103. Structural concrete FlintPrime (ASTM D41) Flintlastic Ultra Glass SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -322.5

C-104. Structural concrete FlintPrime (ASTM D41) Black Diamond Base Sheet (Optional) BP-AA,SBS-AA SBS-AA -240.0

C-105. Structural concrete FlintPrime (ASTM D41) BP-AA, SBS-AA SBS-SA-H SBS-AA, SBS-TA, APP-TA -635.0

Conventional Systems:

C-106. Structural concrete FlintPrime (ASTM D41) APP-TA (Optional) APP-TA APP-TA -420.0

C-107. Structural concrete FlintPrime (ASTM D41) SBS-TA (Optional) SBS-TA SBS-TA -542.5

C-108. Structural concrete FlintPrime (ASTM D41) BP-AA, SBS-AA (Optional) BP-AA,SBS-AA, SBS-TA or APP-TA SBS-AA,SBS-TAor APP-TA -635.0

Cold-Applied Systems:

C-109. Structural concrete FlintPrime (ASTM D41) SBS-CAl (Optional) SBS-CAl SBS-CAl -262.5

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 37 of 57

TRINITY ERDTABLE 4A: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (Tear-Off)

SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOF COVER

System

No.

Deck

(Note 1)

Lightweight Concrete

(Note 13)

Base Insulation Layer Coverboard Roof Cover (Note 14) MDP

(psf)Type Attach Type Attach Base Ply Cap

Self-Adhering Systems:

LWC-l ConcreteMin. 200 psi, min. 2-inch

Elastizell

Min. 1.5-inch ACFoam II,

FlintBoard, ENRGY3 or H-ShieldA-PD, 6-

inch o.c.

Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof BoardA-PD, 6-

inch o.c.SBS-SA (Optional) SBS-SA SBS-SA -172.5

LWC-2 ConcreteMin. 200 psi, min. 2-inch

Elastizell

Min. 1.5-inch ACFoam II,

FlintBoard, ENRGY3 or Multi-MaxFA3

A-PD, 6-

inch o.c.

Min. 0.25-inch Dens Deck

primed with FlintPrime or

FlintPrime SA

A-PD, 6-

inch o.c.SBS-SA (Optional) SBS-SA SBS-SA -187.5

LWC-3 ConcreteMin. 200 psi, min. 2-inchElastizell

Min. 1.5-inch ACFoam II,

FlintBoard ISO or ENRGY 3OB500

Min. 0.25-inch Dens Deck

primed with FlintPrime orFlintPrime SA

OB500 SBS-SA (Optional) SBS-SA SBS-SA -150.0

LWC-4 ConcreteMin. 200 psi, min. 2-inch

Elastizell

Min. 1.5-inch ACFoam II,

FlintBoard, ENRGY 3 or H-ShieldOB500

Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof BoardOB500 SBS-SA (Optional) SBS-SA SBS-SA -172.5

LWC-5 ConcreteMin. 200 psi, min. 2-inch

Celcore, Elastizell or Celcore

Min. 1.0-inch ISO 9S+ GL, H-Shield,

H-Shield CG, ENRGY3 or min. 1.3-inch ACFoam III, Min. 1.5-inch

Multi-Max FA3 or Ultra-Max

CR-20Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof BoardCR-20 SBS-SA (Optional) SBS-SA SBS-SA -172.5

LWC-6 ConcreteMin. 200 psi, min. 2-inch

Celcore, Elastizell or Celcore

Min. 1.0-inch ISO 95+ GL, H-Shield,H-Shield CG, ENRGY3 or min. 1.3-

inch ACFoam III, Min. 1.5-inch

Multi-Max FA3 or Ultra-Max

CR-20

Min. 0.25-inch Dens Deck

primed with FlintPrime or

FlintPrime SA

CR-20 SBS-SA (Optional) SBS-SA SBS-SA -180.0

CONVENTIONAL SYSTEMS:

LWC-7 ConcreteMin. 200 psi, min. 2-inch

Elastizell

Min. 1.5-inch ACFoam II,

FlintBoard ISO, ENRGY 3 or H-Shield

A-PD

6-inch

o.c.

Min. 0.5-inch Structodek

High Density Fiberboard orMin. 0.25-inch Dens Deck

A-PD

6-inch

o.c.

BP-AA or SBS-

AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-187.5

LWC-8 ConcreteMin. 200 psi, min. 2-inch

Elastizell

Min. 1.5-inch ACFoam II,

FlintBoard ISO, ENRGY 3 or H-Shield

A-PD, 6-

inch o.c.

Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof BoardA-PD, 6-

inch o.c.

BP-AA or SBS-

AA, SBS-TA or

APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-217.5

LWC-9 ConcreteMin. 200 psi, min. 2-inch

Elastizell

Min. l.S-inch ACFoam II or

FlintBoard ISO.OBS00

Min. 0.25-inch Dens Deck

or Dens Deck PrimeOB500

BP-AA, SBS-

AA, SBS-TA or

APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-150.0

LWC-10 ConcreteMin. 200 psi, min. 2-inch

Elastizell

Min. 1.5-inch ACFoam II or

FlintBoard ISO.OB500

Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof BoardOB500 SBS-TA (Optional) SBS-TA SBS-TA -180.0

LWC-11 ConcreteMin. 200 psi, min. 2-inch

Elastizell

Min. 2-inch ACFoam II, FlintBoardISO, ENRGY 3 or H-Shield

OB500Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof BoardOB500

BP-AA, SBS-

AA, SBS-TA or

APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-225.0

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666™ EDITION (2017)FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19

Revision 20: 09/14/2017

Appendix 1, Page 38 of 57

TRINITY ERDTABLE 4A: LIGHTWEIGHT CONCRETE DECKS-NEW CONSTRUCTION OR REROOF (TEAR-OFF)

SYSTEMTYPE A-l: BONDED INSULATION, BONDED ROOF COVER

System

No.

Deck

(Note 1)

Lightweight Concrete

(Note 13)

Base Insulation Layer Coverboard Roof Cover (Note 14) MDP

(psflType Attach Type Attach Base Ply Cap

LWC-12 ConcreteMin. 200 psi, min. 2-inch

Celcore, Elastizell or Celcore

Min. 1.0-inch ISO 95+ GL, H-Shield,H-Shield CG, ENRGY 3 or min. 1.3-

inch ACFoam III, Min. 1.5-inch

Multi-Max FA3 or Ultra-Max

CR-20

Min. 0.5-inch Structodek

High Density Fiberboard orDuraBoard (homogeneous)or min. 1.5-inch

FescoBoard (laminated)

CR-20BP-AA or SBS-

AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-180.0

LWC-13 ConcreteMin. 200 psi, min. 2-inchCelcore, Elastizell or Celcore

Min. 1.0-inch ISO 95+ GL, H-Shield,H-Shield CG, ENRGY3 or min. 1.3-

inch ACFoam III, Min. 1.5-inchMulti-Max FA3 or Ultra-Max

CR-20

Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof Boardor Dens Deck or Dens Deck

Prime

CR-20

BP-AA, SBS-

AA, SBS-TA or

APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-180.0

Cold Appued Systems:

LWC-14

Min. 22 ga.

steel at max

5 ft spans orstructural

concrete

Min. 350 psi, min 2-inchRange II Elastizell LightweightInsulating Concrete with ZellFibers.

Min. l.S-inch H-Shield CG

OB500,

6-inch

o.c.

(Optional) Additionallayers of base insulation

OB500,

6-inch

o.c.

BP-CA3 or

SBS-CA3

(Optional) BP-CA3orSBS-CA3

SBS-CA3 -60.0

LWC-15

Min. 22 ga.

steel at max

5 ft spans or

structural

concrete

Min. 350 psi, min 2-inchRange II Elastizell LightweightInsulating Concrete with ZellFibers. When walkable,

attach LWC with Flintfast #14

and Flintfast 3" Round Plates

at 1 per 8 ft2 throughto thestructural deck.

Min. 1.5-inch H-Shield CG

OB500,

6-inch

o.c.

(Optional) Additionallayers of base insulation

OB500,

6-inch

o.c.

BP-CA3 or

SBS-CA3

(Optional) BP-CA3or SBS-CA3

SBS-CA3 -67.5

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 39 of 57

TRINITY erdTABLE 4B: UGHTWEIGHT CONCRETE DECKS- NEW CONSTRUCTION or REROOF (Tear-Off)

SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER

System

No.

Deck

(Note 1)

LWC

(Note 13)

Anchor Sheet Insulation Roof Cover (Note 14)MDP (psf)

Type Fasteners Attach Base Top Attach Base Ply Cap

LWC-16

Min. 22 ga.

steel or

structural

concrete deck.

Minimum 350 psi,

minimum 2-inch

Elastizell cellular LWIC

Yosemite

Venting

Base

ES FM-90

Base Ply

Fasteners

7-inch o.c. at the 4-inch

side lap and 7-inch o.c.at two, equally spaced,staggered rows in thecenter of the sheet

Min. 1.5-

inch

ACFoam II

(Optional)Additional

layers baseinsulation

Hot

asphalt

BP-AA3,18-

inch grid

(Optional)BP-AA,

SBS-AA

SBS-AA -37.5*

LWC-17

Min. 22 ga.

steel or

structural

concrete deck.

Minimum 350 psi,

minimum 2-inch

Approved or existingcellular LWIC Wore: To

qualify the LWIC underthis assembly, thesubjectfastener shallachieve an averagewithdrawal of88 Ibfwhen tested per TAS105 or ANSI/SPRIFX-1.

Yosemite

Venting

Base

ES Twin-Loc

Nails

9-inch o.c. at the 4-inch

side lap and 9-inch o.c.

at two, equally spaced,staggered rows in thecenter of the sheet

Min. l.S-

inch

ACFoam II

(Optional)Additional

layers base

insulation

Hot

asphalt

BP-AA4,18-

inch o.c.

(Optional)BP-AA,

SBS-AA

SBS-AA -60.0

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19

Revision 20: 09/14/2017Appendix 1, Page 40 of 57

TRINITY ERD

TABLE 4C: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION or REROOF (Tear-Off)SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER

System

No.

Deck

(Note 1)Lightweight Concrete (Note 13)

Base Sheet Roof Cover (Note 14)MDP (psf)

Type Fasteners Attach Ply Cap

Self-Adhering Systems:

LWC-18

Min. 22 ga.

steel at max

5 ft spans orstructural

concrete

Min. 300 psi, min. 2-inch Approved cellularlightweight insulating concrete. Note: Toqualifythe LWICunder this assembly, a 1.8-inch TrufastTwin Loc-Nail Assembled Fastener shall achieve an

average withdrawal of 73 Ibf when tested per TAS105 or ANSI/SPRI FX-1

Flintlastic SA NailBase

Trufast Twin Loc-Nail

Assembled Fastener

(min. 1.8")

7-inch o.c. at the min. 2-inch lap and 7-incho.c. in two (2), equally spaced, staggeredcenter rows; Stress plates shall be primedwith FlintPrime (ASTM D41) primer or

FlintPrime SA

SBS-SA SBS-SA -60.0

LWC-19

Min. 22 ga.

steel at max

5 ft spans or

structural

concrete

Min. 300 psi, min. 2-inch Approved cellularlightweight insulating concrete. Wore: Toqualifythe LWICunder this assembly, a 1.8-inch TrufastTwin Loc-Nail Assembled Fastener shall achieve an

average withdrawal of 93 Ibf when tested per TAS105 or ANSI/SPRIFX-1

Flintlastic SA NailBase

Trufast Twin Loc-Nail

Assembled Fastener

(min. 1.8")

9-inch o.c. at the min. 2-inch lap and 9-incho.c. in two (2), equally spaced, staggeredcenter rows; Stress plates shall be primedwith FlintPrime (ASTM D41) primer or

FlintPrime SA

SBS-SA SBS-SA -60.0

Hybrid Systems:

LWC-20

Min. 26 ga.

steel at max

5 ft spans orstructural

concrete

Min. 200 psi, min 2-inch Range II ElastizellLightweight Insulating Concrete.

Glasbase; FlexiglasBase; Flintlastic Base

20; AllWeather/Empire Base or PolySMS Base

Trufast FM-90 Base

Sheet Fasteners or

Trufast Twin Loc-Nail

Assembled Fasteners

(1.8 inch)

754-inch o.c. at the 4-inch lap and 7J4-incho.c. in two (2), equally spaced, staggeredcenter rows

SBS-SA-H

SBS-AA,

SBS-TA or

APP-TA

-30.0

LWC-21

Min. 22 ga.

steel at max

5 ft spans orstructural

concrete

Min. 200 psi, min 2-inch Range II ElastizellLightweight Insulating Concrete.

Glasbase; Flexiglas

Base; Flintlastic Base

20; All Weather/Empire Base or PolySMS Base

Trufast FM-90 Base

Sheet Fasteners or

Trufast Twin Loc-Nail

Assembled Fasteners

(1.8 inch)

7-inch o.c. at the 4-inch lap and 7-inch o.c. intwo (2), equally spaced, staggered centerrows

SBS-SA-H

SBS-AA,

SBS-TA or

APP-TA

-45.0

LWC-22

Min. 22 ga.

steel at max

5 ft spans orstructural

concrete

Min. 300 psi, min. 2-inch Approved cellularlightweight insulatingconcrete. Note: Toqualifythe LWIC under this assembly, a 1.8-inch TrufastTwin Loc-Nail Assembled Fastener shall achieve an

average withdrawal of 88 Ibfwhen tested per TAS105 or ANSI/SPRIFX-1

Glasbase; FlexiglasBase; Flintlastic Base20; All Weather/

Empire Base

Trufast Twin Loc-Nail

Assembled Fastener

(min. 1.8")

9-inch o.c. at the 4-inch lap and 9-inch o.c. intwo (2), equally spaced, staggered centerrows

SBS-SA-H

SBS-AA,

SBS-TA or

APP-TA

-60.0

LWC-23

Min. 22 ga.

steel at max

5 ft spans or

structural

concrete

Min. 350 psi, min. 3-inch Approved cellularlightweight insulating concrete. Note: Toqualifythe LWICunder this assembly, a 1.8-inch TrufastTwin Loc-Nail Assembled Fastener shall achieve an

average withdrawal of 97 Ibfwhen tested per TAS105 or ANSI/SPRIFX-1

Flexiglas Base;Flintlastic Base 20 or

Poly SMS Base

Trufast FM-90 Base

Sheet Fasteners

7-inch o.c. at the 4-inch lap and 10-inch o.c.

in two (2), equally spaced, staggered center

rows

SBS-SA-H

SBS-AA,

SBS-TA or

APP-TA

-67.5

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

6™ EDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 41 of 57

TRINITY ERDTABLE4C: LIGHTWEIGHTCONCRETEDECKS - NEW CONSTRUCTION or REROOF(Tear-Off)

SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER

System

No.

Deck

(Note 1)Lightweight Concrete (Note 13)

Base Sheet Roof Cover (Note 14)MDP (psf)

Type Fasteners Attach Ply Cap

LWC-24

Min. 22 ga.

steel at max

5 ft spans orstructural

concrete

Min. 300 psi, min. 2-inch Approved cellularlightweight insulating concrete. Note: Toqualifythe LWIC under this assembly, a 1.8-inch TrufastTwin Loc-Nail Assembled Fastener shall achieve an

average withdrawal of 110 Ibf when tested per TAS105 or ANSI/SPRIFX-1

Poly SMS Base; UltraPoly SMS Base

Trufast Twin Loc-Nail

Assembled Fastener

(min. 1.8")

9-inch o.c. at the 4-inch lap and 9-inch o.c. in

two (2), equally spaced, staggered centerrows

SBS-SA-H

SBS-AA,

SBS-TA or

APP-TA

-75.0

Conventional Systems :

LWC-25

Min. 26 ga.

steel at max

5 ft spans orstructural

concrete

Min. 200 psi, min 2-inch Range II ElastizellLightweight Insulating Concrete.

Glasbase; FlexiglasBase; Flintlastic Base

20; All Weather/Empire Base; PolySMS Base; Yosemite

Trufast FM-90 Base

Sheet Fasteners or

Trufast Twin Loc-Nail

Assembled Fasteners

(1.8 inch)

7/j-inch o.c. at the 4-inch lap and 754-incho.c. in two (2), equally spaced, staggeredcenter rows

(Optional)

BP-AA,

SBS-AA,

SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-30.0

LWC-26

Min. 26 ga.

steel at max

5 ft spans orstructural

concrete

Min. 200 psi, min 2-inch Range II ElastizellLightweight Insulating Concrete.

Flintlastic APP Base TTrufast FM-90 Base

Sheet Fasteners

7J4-inch o.c. at the 4-inch lap and 734-incho.c. in two (2), equally spaced, staggeredcenter rows

(Optional)APP-TA

APP-TA -30.0

LWC-27

Min. 22 ga.

steel at max

5 ft spans orstructural

concrete

Min. 200 psi, min 2-inch Range II ElastizellLightweight Insulating Concrete.

Glasbase; FlexiglasBase; Flintlastic Base

20; All Weather/

Empire Base; Poly

SMS Base; Yosemite

Trufast FM-90 Base

Sheet Fasteners or

Trufast Twin Loc-Nail

Assembled Fasteners

(1.8 inch)

7-inch o.c. at the 4-inch lap and 7-inch o.c. intwo (2), equally spaced, staggered centerrows

(Optional)

BP-AA,

SBS-AA,

SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-45.0

LWC-28

Min. 22 ga.

steel at max

5 ft spans orstructural

concrete

Min. 200 psi, min 2-inch Range II ElastizellLightweight Insulating Concrete.

Flintlastic APP Base TTrufast FM-90 Base

Sheet Fasteners

7-inch o.c. at the 4-inch lap and 7-inch o.c. intwo (2), equally spaced, staggered centerrows

(Optional)

APP-TAAPP-TA -45.0

LWC-29

Min. 22 ga.

steel at max

5 ft spans orstructural

concrete

Min. 250 psi, min 2-inch Mearlcrete.

Glasbase; FlexiglasBase; Flintlastic Base

20; All Weather/Empire Base; PolySMS Base; Yosemite

OMG CR Base Ply

Fasteners (1.7)

7-inch o.c. at the 4-inch lap and 7-inch o.c. intwo (2), equally spaced, staggered centerrows

(Optional)BP-AA or

SBS-AA

SBS-AA,

SBS-TA or

APP-TA

-45.0

LWC-30

Min. 22 ga.

steel at max

5 ft spans orstructural

concrete

Min. 250 psi, min 2-inch Mearlcrete. Poly SMS BaseOMG CR Base PlyFasteners (1.7)

7-inch o.c. at the 4-inch lap and 7-inch o.c. intwo (2), equally spaced, staggered centerrows

(Optional)BP-AA or

SBS-AA

SBS-AA,

SBS-TA or

APP-TA

-52.5

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666thEDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19

Revision 20: 09/14/2017Appendix 1, Page 42 of 57

TRINITY ERDTABLE 4C: UGHTWEIGHT CONCRETE DECKS - NEWCONSTRUCTION OR REROOF (Tear-Off)

SYSTEM TYPE E: MECHANICALLYATTACHED BASE SHEET, BONDED ROOFCOVER

System

No.

Deck

(Note 1)Lightweight Concrete (Note 13)

Base Sheet Roof Cover (Note 14)MDP (psf)

Type Fasteners Attach Ply Cap

LWC-31

Min. 22 ga.

steel at max

5 ft spans orstructural

concrete

Min. 300 psi, min 2-inch Mearlcrete.

Glasbase; Flexiglas

Base; Flintlastic Base

20; All Weather /Empire Base; PolySMS Base; Yosemite

OMG CR Base Ply

Fasteners (1.7)

7-inch o.c. at the 4-inch lap and 7-inch o.c. intwo (2), equally spaced, staggered center

rows

(Optional)BP-AA or

SBS-AA

SBS-AA,

SBS-TA or

APP-TA

-52.5

LWC-32

Min. 22 ga.

steel at max

5 ft spans orstructural

concrete

Concrecel Bonding Agent on deck; Min. 300 psi, min2%-inch Concrecel Concrete.

Glasbase; FlexiglasBase; Flintlastic Base20; AllWeather/Empire Base; PolySMS Base; Yosemite

OMG CR Base PlyFasteners (1.7)

7-inch o.c. at the 3-inch lap and 7-inch o.c. intwo (2), equally spaced, staggered centerrows

(Optional)

BP-AA or

SBS-AA

SBS-AA,

SBS-TA or

APP-TA

-52.5

LWC-33

Min. 22 ga.

steel at max

5 ft spans orstructural

concrete

Min. 300 psi, min. 2-inch Approved cellularlightweight insulating concrete. Note: To qualifythe LWIC under this assembly, a 1.8-inch TrufastTwin Loc-Nail Assembled Fastener shall achieve an

average withdrawal of 88 Ibfwhen tested per TAS105 or ANSI/SPRIFX-1

Glasbase; Flexiglas

Base; Flintlastic Base

20; AllWeather/Empire Base;

Yosemite

Trufast Twin Loc-Nail

Assembled Fastener

(min. 1.8")

9-inch o.c. at the 4-inch lap and 9-inch o.c. intwo (2), equally spaced, staggered centerrows

(Optional)BP-AA,

SBS-AA,

SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-60.0

LWC-34

Min. 22 ga.,

type B steelat max. 5 ft

spans

structural

concrete

Min. 300 psi, min 2-inch Celcore MFCellularConcrete with Celcore HS Rheology ModifyingAdmixture. After setting to support foot traffic,Celcore PVA Curing Compound is applied.

AllWeather/Empire

Base; Flintlastic Base

20; Poly SMS Base

Trufast FM-90 Base

Sheet Fasteners

9-inch o.c. at 4-inch laps and 12-inch o.c. intwo (2), equally spaced, staggered centerrows

(Optional)BP-AA,

SBS-AA or

SBS-TA-F

SBS-AA or

SBS-TA-F-60.0

LWC-35

Min. 22 ga.

steel at max

5 ft spans orstructural

concrete

Min. 300 psi, min. 2-inch Approved cellularlightweightinsulatingconcrete. Note:To qualifythe LWICunder this assembly, a 1.8-inch TrufastTwin Loc-Nail Assembled Fastener shall achieve an

average withdrawal of 77 Ibfwhen tested per TAS105 or ANSI/SPRI FX-1

Glasbase; FlexiglasBase; Flintlastic Base

20; AllWeather/Empire Base;Yosemite

Trufast Twin Loc-Nail

Assembled Fastener

(min. 1.8")

7-inch o.c. at the 4-inch lap and 7-inch o.c. intwo (2), equally spaced, staggered centerrows

BP-AA or

SBS-AA

SBS-AA,

SBS-TA or

APP-TA

-67.5

LWC-36

Min. 22 ga.

steel at max

5 ft spans orstructural

concrete

Min. 350 psi, min. 3-inch Approved cellularlightweightinsulatingconcrete. Wore: To qualifythe LWICunder this assembly, a 1.8-inch TrufastTwin Loc-Nail Assembled Fastener shall achieve an

average withdrawal of 97 Ibfwhen tested per TAS105 or ANSI/SPRI FX-1

Flexiglas Base;Flintlastic Base 20;

Poly SMS Base;

Yosemite

Trufast FM-90 Base

Sheet Fasteners

7-inch o.c. at the 4-inch lap and 10-inch o.c.in two (2), equally spaced, staggered centerrows

BP-AA,

SBS-AA,

SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-67.5

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

6thEDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 43 of 57

System

No.

LWC-37

LWC-38

Deck

(Note 1)

Min. 22 ga.

steel at max

5 ft spans orstructural

concrete

Min. 22 ga.

steel at max

5 ft spans orstructural

concrete

Cold Appued Systems:

LWC-39

LWC-40

LWC-41

Min. 22 ga.steel at max

5 ft spans orstructural

concrete

Min. 22 ga.

steel at max

5 ft spans

Structural

concrete

TABLE 4C: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION or REROOF (Tear-Off)SYSTEMTYPEE: MECHANICALLY ATTACHED BASESHEET, BONDED ROOFCOVER

Lightweight Concrete (Note 13)

Min. 300 psi, min. 2-inch Approved cellularlightweight insulatingconcrete. Note: Toqualifythe LWIC under thisassembly, a 1.8-inchTrufastTwin Loc-Nail Assembled Fastener shall achieve anaverage withdrawal of 110 Ibfwhen tested per TAS105 or ANSI/SPRIFX-1

Min. 300 psi, min 2-inch Celcore Cellular Concrete.After setting to support foot traffic, Celcore PVACuring Compound is applied.

Min. 350 psi, min 2-inch Range IIElastizellLightweight Insulating Concrete with Zell Fibers.

Min. 350 psi, min 2-inch Range II ElastizellLightweight Insulating Concrete with Zell Fibers.

Min. 350 psi, min 2-inch Range II ElastizellLightweight Insulating Concrete with Zell Fibers.

Type

Poly SMS Base; UltraPoly SMS Base

Glasbase; FlexiglasBase; Flintlastic Base

20; All Weather/

Empire Base; Poly

SMS Base; Yosemite

Flintlastic Base 20;

Poly SMS Base

Glasbase; FlexiglasBase; Poly SMS Base

Glasbase; FlexiglasBase; Poly SMS Base

Base Sheet

Fasteners

Trufast Twin Loc-Nail

Assembled Fastener

(min. 1.8")

Trufast FM-90 Base

Sheet Fasteners

Trufast FM-90 Base

Sheet Fasteners

Trufast FM-90 Base

Sheet Fasteners

Trufast FM-90 Base

Sheet Fasteners

Attach

9-inch o.c. at the 4-inch lap and 9-inch o.c. intwo (2), equally spaced, staggered centerrows

7-inch o.c. at the 3-inch lap and 7-inch o.c. intwo (2), equally spaced, staggered centerrows

7-inch o.c. at the 4-inch lap and 7-inch o.c. intwo (2), equally spaced, staggered centerrows

7-inch o.c. at the 4-inch lap and 7-inch o.c. intwo (2), equally spaced, staggered centerrows

7-inch o.c. at the 4-inch lap and 7-inch o.c. intwo (2), equally spaced, staggered centerrows

TRINITY ERD

Roof Cover (Note 14)

Ply

BP-AA,

SBS-AA,

SBS-TA or

APP-TA

BP-AA or

SBS-AA

(Optional)BP-CA2 or

SBS-CA2

(Optional)BP-CA3 or

SBS-CA3

(Optional)BP-CA3 or

SBS-CA3

Cap

SBS-AA,

SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

SBS-CA2

SBS-CA3

SBS-CA3

MDP (psf)

-75.0

-75.0

-45.0

-52.5

-60.0

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666,M EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19

Revision 20: 09/14/2017Appendix 1, Page 44 of 57

TABLE5A

:C

EMEN

TITIOU

SW

OO

DFIBER

DECKS

-N

EW

CO

NSTRU

CTIO

Nor

REROO

F(T

ear-Off)

SYST

EM

TY

PE

A-l:

BO

ND

ED

INSU

LA

TIO

N,

BO

ND

ED

RO

OF

CO

VE

R

Syste

m

No

.

Deck

(No

te1)

Ba

seIn

sula

tion

La

yer

Typ

e

Self-A

dh

erin

gS

yste

ms:

CW

F-1

.T

ectu

m

CW

F-2

.T

ectu

m

Min.

1.5-inchFlintB

oardISO

,AC

FoamII,EN

RG

Y3

orM

ulti-

Max

FA

3

Min.

1.0-inchISO

95+G

L,H

-Shield,H

-ShieldC

G,EN

RG

Y3

orm

in.1.3-inch

AC

FoamIII,M

in.l.S

-inchM

ulti-Max

FA3

or

Ultra

-Max

Co

nven

tion

al

Syste

ms:

CW

F-3

.T

ectu

m

CW

F-4

.T

ectu

m

CW

F-5

.T

ectu

m

CW

F-6

.T

ectu

m

Min.

1.5-inchF

lintBoard

ISO,A

CFoam

II,ENR

GY

3or

Multi-

Max

FA

3

Min.

1.5-inchF

lintBoard

ISO,A

CFoam

II,ENR

GY

3or

Multi-

Max

FA

3

Min.

1.0-inchISO

95

+G

L,H

-Shield,

H-S

hieldC

G,EN

RG

Y3

orm

in.1.3-inch

AC

FoamIII,M

in.1.5-inch

Multi-M

axFA

3

or

Ultra

-

Min.

1.0-inchISO

95+G

L,H

-Shield,H

-ShieldC

G,EN

RG

Y3

or

min.

1.3-inchA

CFoam

III,Min.

1.5-inchM

ulti-Max

FA3

or

Ultra

-Max

Atta

ch

OB

50

0

CR

-20

OB

50

0

OB

50

0

CR

-20

CR

-20

To

pIn

sula

tion

Layer

Typ

e

Min.

0.25-inchD

ensD

eckp

rimed

with

Flin

tPrim

eo

rF

lintP

rime

SA;o

rSE

CU

RO

CK

Gypsum

-FiberR

oofBoard

Min.

0.25-inchD

ensD

eckp

rimed

with

Flin

tPrim

eo

rF

lintP

rime

SA;o

rSE

CU

RO

CK

Gypsum

-Fiber

RoofB

oard

Min.

0.5-inchS

tructo

dek

High

Density

Fib

erb

oard

Min.

0.25-inchSEC

UR

OC

KG

ypsum-F

iberR

oo

fB

oard

or

Den

sD

ecko

rD

ens

Deck

Prim

e

Min.

0.5-inchS

tructo

dek

High

Density

Fiberboard

orD

uraB

oard(hom

ogeneous)or

min.

1.5-inchF

escoBoard

(laminated)

Min.0.25-inch

SECU

RO

CK

Gypsum

-Fiber

Ro

of

Bo

ardo

rD

ens

Deck

or

Den

sD

eck

Prim

e

Atta

ch

OB

50

0

CR

-20

OB

50

0

OB

50

0

CR

-20

CR

-20

Exterior

Research

andD

esign,LLC.d/b

/aT

rinity|ERD

Certific

ate

of

Au

tho

rizatio

n#

95

03

Prep

aredby:

Ro

bert

Niem

inen,P

E-59166

6™ED

ITION

(2017)FBCN

ON

-HVH

ZEVALU

ATION

CertainT

eedF

lintlastic*M

odifiedB

itum

enR

oo

fSystem

s;(610)

651-5847

Ba

se

SB

S-S

A

SB

S-S

A

BP

-AA

or

SB

S-A

A

BP-A

A,SB

S-

AA

,SB

S-TA

or

AP

P-T

A

BP

-AA

or

SB

S-A

A

BP-A

A,

SBS-

AA

,SB

S-TA

or

AP

P-T

A

TR

INIT

YERD

Ro

ofC

over(N

ote

14)

Ply

(Optional)

SBS-SA

(Optional)

SBS-SA

(Optional)

BP-A

A,

SBS-A

A,

SBS-T

Ao

r

AP

P-T

A

(Optional)

BP-A

A,

SBS-A

A,SB

S-TA

or

AP

P-T

A

(Optional)

BP-A

A,

SBS-A

A,SB

S-TA

or

AP

P-T

A

(Optional)

BP-A

A,

SBS-A

A,

SBS-T

Ao

r

AP

P-T

A

Cap

SB

S-S

A

SB

S-S

A

SBS-A

A,

SB

S-T

Ao

r

AP

P-T

A

SBS-A

A,

SB

S-T

Ao

r

AP

P-T

A

SBS-A

A,

SB

S-T

Ao

r

AP

P-T

A

SBS-A

A,

SB

S-T

Ao

r

AP

P-T

A

MD

P(psf)

-45

.0*

-52

.5

-45

.0*

-45

.0*

-52

.5

-52

.5

Evaluation

Report

3520.03.04-R20

forF

12533-R19

Revision

20:0

9/1

4/2

01

7

Appendix

1,Page45

of57

TRINITY ERDTABLE 5B: CEMENTITIOUS WOOFFIBER DECKS - NEWCONSTRUCTION or REROOF (Tear-Off)

SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVERSystem

No.

Deck

(Note 1)

Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 14)MDP (psf)Type Fasteners Attach Type Attach Type Attach Base Ply Cap

Hybrid Systems:

CWF-7. Tectum

Glasbase; FlexiglasBase; Flintlastic Base

20; All Weather/

Empire Base; Yosemite

Trufast Twin

Loc-Nail

Assembled

Fastener

(min. 1.8")

7-inch o.c. at the 4-

inch lap and 7-incho.c. in two (2),

equally spaced,staggered center

rows

Min. 1.5-inch

ACFoam II,

FlintBoard ISO,

ENRGY 3 or Multi-

Max FA3

HA None N/ASBS-SA-

H

(Optional)

SBS-AA,

SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-60.0

Conventional Systems:

CWF-8. Tectum

Glasbase; FlexiglasBase; Flintlastic Base

20; All Weather/Empire Base; Yosemite

Trufast Twin

Loc-Nail

Assembled

Fastener

(min. 1.8")

7-inch o.c. at the 4-

inch lap and 7-incho.c. in two (2),

equally spaced,staggered centerrows

Min. 1.5-inch

ACFoam II,

FlintBoard ISO,

ENRGY 3 or Multi-

Max FA3

HA

Min. 0.75-inch

FescoBoard

(homogeneous) or min.0.5-inch Structodek

High Density Fiberboard

HA

BP-AA

or SBS-

AA

(Optional)

BP-AA or

SBS-AA

SBS-AA,

SBS-TA or

APP-TA

-60.0

TABLE 5C: CEMENTITIOUS WOOD FIBER DECKS - NEWCONSTRUCTION, REROOF (Tear-Off) or RECOVERSYSTEM TYPEC: MECHANICALLY ATTACHED INSULATION, BONDEDROOFCOVER

System

No.

Deck

(Note 1)Base Insulation Layer(s)

Top Insulation Layer Roof Cover (Note 14)MDP (psf)Type Fasteners Attach Base Ply Cap

CWF-9. Tectum

(Optional) One or morelayers, any combination,loose laid

Min. 0.5-inch Structodek HighDensity Fiberboard RoofInsulation

OMG Polymer GypTec with 3"GypTec Plate

1 per 2 ft* BP-AA or SBS-

AA

(Optional) BP-AA,

SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-45.0*

CWF-10. Tectum

(Optional) One or morelayers, any combination,loose laid

Min. 0.25-inch Dens Deck or

Dens Deck Prime

OMG Polymer GypTec with 3"GypTec Plate

1 per 1.78ft'BP-AA, SBS-

AA, SBS-TA or

APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-45.0*

CWF-11. Tectum

(Optional) One or morelayers, any combination,loose laid

Min. 0.5-inch Structodek HighDensity Fiberboard Roof

Insulation

Trufast Twin Loc-Nail

Assembled Fasteners

(minimum 1-inch embedmentinto deck)

1 per 2 ft' BP-AA or SBS-

AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-45.0*

CWF-12. Tectum

(Optional) One or morelayers, any combination,loose laid

Min. 0.25-inch Dens Deck or

Dens Deck Prime or

SECUROCK Gypsum-FiberRoof Board

Trufast Twin Loc-Nail

Assembled Fasteners

(minimum 1-inch embedmentinto deck)

1 per 2 ft2BP-AA, SBS-

AA, SBS-TA or

APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-45.0*

ExteriorResearch and Design,LLC. d/b/a Trinity| ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 46 of 57

TRINITY ERD

TABLE5D: CEMENTITOUSWOOD FIBER DECKS - NEW CONSTRUCTIONOR REROOF(Tear-Off)

SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER

System

No.

Deck

(Note 1)

Base Sheet Roof Cover (Note 14)MDP (psf)

Base Fasteners Attach Ply Cap

Self-Adhering Systems:

CWF-13. Tectum Flintlastic SA NailBase

Trufast Twin Loc-Nail

Assembled Fastener (min.

1.8")

7-inch o.c. at the 4-inch lap and 7-inch o.c. in two(2), equally spaced, staggered center rows

SBS-SA SBS-SA -60.0

Conventional Systems:

CWF-14. Tectum All Weather / Empire Base; YosemiteTrufast Insuldeck Loc-Nail Base

Sheet Fastener

9-inch o.c. at the 4-inch lap and 12-inch o.c. in two(2), equally spaced, staggered center rows

BP-AA or SBS-AA SBS-AA -30.0*

CWF-15. Tectum All Weather / Empire Base; YosemiteTrufast Insuldeck Loc-Nail Base

Sheet Fastener

734-inch o.c. at the 4-inch lap and 7K-inch o.c. intwo (2), equally spaced, staggered center rows

BP-AA or SBS-AA SBS-AA -45.0*

CWF-16. TectumGlasbase; FlexiglasBase; All Weather /Empire Base; Yosemite

Simplex Turbo Tube-Lok9-inch o.c. at the 4-inch lap and 12-inch o.c. in two(2), equally spaced, staggered center rows

SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-45.0*

CWF-17. TectumGlasbase; Flexiglas Base; Flintlastic Base20 or All Weather / Empire Base; Yosemite

Trufast Twin Loc-Nail

Assembled Fastener (min.

1.8")

7-inch o.c. at the 4-inch lap and 7-inch o.c. in two

(2), equally spaced, staggered center rowsBP-AA or SBS-AA

SBS-AA,

SBS-TA or

APP-TA

-67.5

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 47 of 57

TRINITY erdTABLE 6A: GYPSUM DECKS-REROOF (Tear-Off)

SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOF COVER

System

No.Deck

Base Insulation Layer Top Insulation Layer Roof Cover (Note 14)MDP (psf)

Type Attach Type Attach Base Ply Cap

Self-Adhering Systems:

G-l.

Existing soundgypsum or

gypsum plank

Min. l.S-inch ACFoam II, FlintBoard, ENRGY 3 or H-Shield

M-OSFAMin. 0.25-inch SECUROCK

Gypsum-Fiber Roof BoardM-OSFA SBS-SA (Optional) SBS-SA SBS-SA -172.5

G-2.

Existing soundgypsum or

gypsum plank

Min. 1.5-inch ACFoam II, FlintBoard, ENRGY 3 orMulti-Max FA

M-OSFAMin. 0.25-inch Dens Deck primed

with FlintPrime or FlintPrime SAM-OSFA SBS-SA (Optional) SBS-SA SBS-SA -192.5

G-3.

Existing soundgypsum or

gypsum plankMin. 1.5-inch ACFoam II, FlintBoard ISO or ENRGY3 OB500

Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA

or SECUROCK Gypsum-Fiber RoofBoard

OB500 SBS-SA (Optional) SBS-SA SBS-SA -135.0

G-4.

Existing soundgypsum or

gypsum plank

Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG,

ENRGY3 or min. 1.3-inch ACFoam III, Min. 1.5-inchMulti-Max FA3 or Ultra-Max

CR-20Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof BoardCR-20 SBS-SA (Optional) SBS-SA SBS-SA -172.5

G-5.

Existing soundgypsum or

gypsum plank

Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG,ENRGY3 or min. 1.3-inch ACFoam III, Min. 1.5-inchMulti-Max FA3 or Ultra-Max

CR-20Min. 0.25-inch Dens Deck primed

with FlintPrime or FlintPrime SACR-20 SBS-SA (Optional) SBS-SA SBS-SA -192.5

Conventional Systems:

G-6.

Existing soundgypsum or

gypsum plank

Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY3 orH-Shield

M-OSFAMin. 0.5-inch Structodek High

Density FiberboardM-OSFA

BP-AA or SBS-

AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-127.5

G-7.

Existing soundgypsum or

gypsum plank

Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY3 or

H-ShieldM-OSFA Min. 0.25-inch Dens Deck M-OSFA

BP-AA or SBS-

AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-232.5

G-8.

Existing sound

gypsum or

gypsum plank

Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY3 or

H-ShieldM-OSFA

Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof BoardM-OSFA

BP-AA or SBS-

AA, SBS-TA or

APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-202.5

G-9.

Existing sound

gypsum or

gypsum plank

Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY3 orH-Shield

OB500Min. 0.5-inch Structodek HighDensity Fiberboard

OB500BP-AA or SBS-

AA

(Optional) BP-AA,

SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-120.0

G-10.

Existing sound

gypsum or

gypsum plank

Min. l.S-inch ACFoam II, FlintBoard ISO, ENRGY3 or

H-ShieldOB500

Min. 0.25-inch Dens Deck, Dens

Deck Prime or SECUROCK

Gypsum-Fiber Roof BoardOB500

BP-AA, SBS-

AA, SBS-TA or

APP-TA

(Optional) BP-AA,

SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-135.0

G-ll.

Existing soundgypsum or

gypsum plank

Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG,ENRGY3 or min. 1.3-inch ACFoam III, Min. 1.5-inchMulti-Max FA3 or Ultra-Max

CR-20Min. 0.25-inch Dens Deck or Dens

Deck PrimeCR-20 SBS-TA (Optional) SBS-TA SBS-TA -180.0

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666™ EDITION (2017)FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19

Revision 20:09/14/2017Appendix 1, Page 48 of 57

System

No.

G-12.

G-13.

G-14.

G-15.

Deck

Existing soundgypsum or

gypsum plank

Existing soundgypsum or

gypsum plank

Existing soundgypsum or

gypsum plank

Existing soundgypsum or

gypsum plank

TABLE6A: GYPSUM DECKS- REROOF(Tear-Off)

SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOF COVER

Base Insulation Layer

Type

Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG,ENRGY3 or min. 1.3-inch ACFoam III, Min. 1.5-inch

Multi-Max FA3 or Ultra-Max

Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG,ENRGY 3 or min. 1.3-inch ACFoam III,Min. 1.5-inchMulti-Max FA3 or Ultra-Max

Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG,ENRGY 3 or min. 1.3-inch ACFoam III,Min. 1.5-inchMulti-Max FA3 or Ultra-Max

Min. 1.0-inch ISO 95+ GL, H-Shield, H-Shield CG,ENRGY3 or min. 1.3-inch ACFoam III, Min. 1.5-inch

Multi-Max FA3 or Ultra-Max

Attach

CR-20

CR-20

CR-20

CR-20

Top Insulation Layer

Type

Min. 0.5-inch Structodek High

Density Fiberboard or DuraBoard(homogeneous) or min. 1.5-inchFescoBoard (laminated)

Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof Board

Min. 0.25-inch SECUROCK

Gypsum-Fiber Roof Board

Min. 0.25-inch Dens Deck

Attach

CR-20

CR-20

CR-20

CR-20

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

6thEDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Base

BP-AA or SBS-

AA

BP-AA or SBS-

AA

SBS-TA or

APP-TA

BP-AA or SBS-

AA

TRINITY ERD

Roof Cover (Note 14)

Ply

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

(Optional) SBS-TAor APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

Cap

SBS-AA,

SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

MDP (psf)

-180.0

-225.0

-232.5

-240.0

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 49 of 57

TRINITY ERDTABLE 6B: GYPSUM DECKS-REROOF(Tear-Off)

SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVERSystem

No.

Deck

(Note 1)

Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 14) MDP

(psf)Type Fasteners Attach Type Attach Type Attach Base Ply CapHybrid Systems:

G-16.

Existing sound

gypsum or

gypsum plank

Glasbase; FlexiglasBase; Flintlastic

Base 20; All

Weather/EmpireBase; Yosemite

Trufast Twin

Loc-Nail

Assembled

Fastener

(min. 1.8")

7-inch o.c. at the 4-

inch lap and 7-inch

o.c. in two (2),equally spaced,staggered centerrows

Min. l.S-inch

ACFoam II,

FlintBoard ISO,

ENRGY 3 or Multi-

Max FA3

HA None N/ASBS-SA-

H

(Optional)SBS-AA,

SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-60.0

Conventional Systems:

G-17.

Existing sound

gypsum or

gypsum plank

All Weather/

Empire Base;

Yosemite

Trufast FM-75

or FM-90

Base Sheet

Fastener

9-inch o.c. at the 4-

inch lap and 18-incho.c. in two (2),

equally spaced,staggered centerrows

(Optional) Min. 1.5-inch ACFoam II,

FlintBoard ISO,ENRGY 3 or Multi-

Max FA3

HA

Min. 0.75-inch

FescoBoard

(homogeneous) or min.0.5-inch Structodek

High Density Fiberboard

HABP-AA or

SBS-AA

(Optional)BP-AA or

SBS-AA

SBS-AA,

SBS-TA or

APP-TA

-45.0*

G-18.

Existing sound

gypsum or

gypsum plank

Glasbase; FlexiglasBase; Flintlastic

Base 20; All

Weather/EmpireBase; Yosemite

Trufast Twin

Loc-Nail

Assembled

Fastener

(min. 1.8")

7-inch o.c. at the 4-

inch lap and 7-incho.c. in two (2),equally spaced,staggered center

rows

Min. 1.5-inch

ACFoam II,

FlintBoard ISO,

ENRGY 3 or Multi-

Max FA3

HA

Min. 0.75-inch

FescoBoard

(homogeneous) or min.0.5-inch Structodek

High Density Fiberboard

HABP-AA or

SBS-AA

(Optional)BP-AA or

SBS-AA

SBS-AA,

SBS-TA or

APP-TA

-60.0

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen RoofSystems; (610)651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19

Revision 20: 09/14/2017Appendix 1, Page 50 of 57

TRINITY ERD

TABLE6C: GYPSUM DECKS - REROOF(Tear-Off)

SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER

System

No.

Deck

(Note 1)Base Insulation Layer(s)

Top Insulation Layer Roof Cover (Note 14)MDP (psf)

Type Fasteners Attach Base Ply Cap

G-19.

Existing soundgypsum or

gypsum plank

(Optional) One or morelayers, any combination,loose laid

Min. 0.5-inch Structodek

High Density FiberboardRoof Insulation

OMG Polymer GypTec with 3"GypTec Plate

1 per 2 ft*BP-AA or SBS-

AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-45.0*

G-20.

Existing soundgypsum or

gypsum plank

(Optional) One or morelayers, any combination,loose laid

Min. 0.25-inch Dens Deck or

Dens Deck Prime

OMG Polymer GypTec with 3"GypTec Plate

1 per 1.78ft2BP-AA, SBS-

AA, SBS-TA or

APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-45.0*

G-21.

Existing soundgypsum or

gypsum plank

(Optional) One or morelayers, any combination,loose laid

Min. 0.5-inch Structodek

High Density FiberboardRoof Insulation

Trufast Twin Loc-Nail Assembled

Fasteners (minimum 1-inchembedment into deck)

1 per 2 ft2BP-AA or SBS-

AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-45.0*

G-22.

Existing soundgypsum or

gypsum plank

(Optional) One or morelayers, any combination,

loose laid

Min. 0.25-inch Dens Deck or

Dens Deck Prime or

SECUROCK Gypsum-FiberRoof Board

Trufast Twin Loc-Nail Assembled

Fasteners (minimum 1-inchembedment into deck)

1 per 2 ft2BP-AA, SBS-

AA, SBS-TA or

APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA,

SBS-TA or

APP-TA

-45.0*

TABLE 6D: GYPSUM DECKS-REROOF (Tear-Off)

SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER

System

No.

Deck

(Note 1)

Base Sheet Roof Cover (Note 14) MDP

(psf)Base Fasteners Attach Ply Cap

Self-Adhering Systems:

G-23.Existing sound gypsumor gypsum plank

Flintlastic SA NailBase

Trufast Twin Loc-Nail

Assembled Fastener

(min. 1.8")

9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2),equally spaced, staggered center rows

SBS-SA SBS-SA -60.0

Conventional Systems:

G-24.Existing sound gypsumor gypsum plank

AllWeather/ Empire Base;Yosemite

Trufast FM-75 or FM-90

Base Sheet Fastener

9-inch o.c. at the 4-inch lap and 18-inch o.c. in two (2),equally spaced, staggered center rows

BP-AA or'SBS-AA SBS-AA -45.0*

G-25.Existing sound gypsumor gypsum plank

Glasbase; Flexiglas Base; AllWeather / Empire Base; Yosemite

Simplex Turbo Tube-Lok9-inch o.c. at the 4-inch lap and 12-inch o.c. in two (2),equally spaced, staggered center rows

SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-45.0*

G-26.Existing sound gypsumor gypsum plank

Glasbase; Flexiglas Base; FlintlasticBase 20; All Weather / EmpireBase; Yosemite

Trufast Twin Loc-Nail

Assembled Fastener

(min. 1.8")

9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2),equally spaced, staggered center rows

BP-AA or SBS-AASBS-AA, SBS-

TA or APP-TA-67.5

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

6thEDITION (2017) FBC NON-HVHZ EVALUATIONCertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 51 of 57

TRINITY ERDTABLE 7A: RECOVER APPLICATIONS

SYSTEM TYPEA-l: BONDEDINSULATION,BONDEDROOFCOVERSystem

No.Substrate (Notes 1 & 11)

Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP

(psf)Type Attach Type Attach Base Ply CapSelf-Adhering Systems:

R-lExisting fully bonded BURormodified bitumen roof cover

Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA; orSECUROCK Gypsum-Fiber RoofBoard.

HA None N/A SBS-SA (Optional) SBS-SA SBS-SA -105.0

R-2Existing fully bonded BURormodified bitumen roof cover

Min. 1.5-inch ACFoam II, FlintBoardISO, ENRGY3, H-Shield or Multi-MaxFA3

HA

Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA; orSECUROCKGypsum-Fiber RoofBoard.

HA SBS-SA (Optional) SBS-SA SBS-SA -105.0

R-3Existing fully bonded, smoothsurface BUR or modified bitumen

Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA or

SECUROCK Gypsum-Fiber RoofBoard

A-PD, 6-

inch o.c.None N/A SBS-SA (Optional) SBS-SA SBS-SA -105.0

R-4Existing fully bonded, mineralsurface modified bitumen

Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

A-PD, 6-

inch o.c.None N/A SBS-SA (Optional) SBS-SA SBS-SA -172.5

R-5Existing fully bonded, mineralsurface modified bitumen

Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA

A-PD, 6-

inch o.c.None N/A SBS-SA (Optional) SBS-SA SBS-SA -180.0

R-6Existing fully bonded, smoothsurface BUR or modified bitumen

Min. 1.5-inch ACFoam II, FlintBoard,ENRGY 3 or Multi-Max FA3

A-PD, 6-

inch o.c.

Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA or

SECUROCK Gypsum-Fiber RoofBoard

A-PD, 6-

inch o.c.SBS-SA (Optional) SBS-SA SBS-SA -52.5

R-7Existing fully bonded, mineralsurface BUR or modified bitumen

Min. 1.5-inch ACFoam II,FlintBoard,ENRGY 3 or Multi-Max FA3

A-PD, 6-

inch o.c.

Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA or

SECUROCK Gypsum-Fiber RoofBoard

A-PD, 6-

inch o.c.SBS-SA (Optional) SBS-SA SBS-SA -172.5

R-8Existing fully bonded BURormodified bitumen roof cover

Min. 1.5-inch ACFoam II, FlintBoard,ENRGY 3 or H-Shield

M-OSFA

Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA or

SECUROCK Gypsum-Fiber RoofBoard

M-OSFA SBS-SA (Optional) SBS-SA SBS-SA -157.5

R-9

Existing fully bonded, smooth- orgranule-surface BUR or modifiedbitumen

Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

M-PGl None N/A SBS-SA (Optional) SBS-SA SBS-SA -172.5

R-10

Existing fully bonded, smooth- orgranule-surface BUR or modifiedbitumen

Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA

M-PGl None N/A SBS-SA (Optional) SBS-SA SBS-SA -180.0

R-llExisting fully bonded BURormodified bitumen roof cover

Min. l.S-inch ACFoam II,FlintBoard,ENRGY 3 or H-Shield

M-PGlMin. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

M-PGl SBS-SA (Optional) SBS-SA SBS-SA -172.5

ExteriorResearch and Design,LLC. d/b/a Trinity| ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610)6S1-S847

Evaluation Report 3520.O3.O4-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 52 of 57

System

No.

R-12

R-13

R-14

R-15

R-16

R-17

R-18

Substrate (Notes 1 8111)

Existing fully bonded BURormodified bitumen roof cover

Existing fully bonded, smooth- orgranule-surface BUR or modifiedbitumen

Existing fully bonded BURormodified bitumen roof cover

Existing fully bonded, smooth- orgranule-surface BURor modifiedbitumen

Existing fully bonded, smooth- orgranule-surface BUR or modifiedbitumen

Existing fully bonded BUR ormodified bitumen roof cover

Existing fully bonded BUR ormodified bitumen roof cover

Hybrid Systems:

R-19

R-20

R-21

R-22

R-23

Existing fully bonded BURor

modified bitumen roof cover

Existing fully bonded, smoothsurface BUR or modified bitumen

Existing fully bonded, mineralsurface modified bitumen

Existing fully bonded, smooth- orgranule-surface BUR or modifiedbitumen

Existing fully bonded, smooth- orgranule-surface BUR or modifiedbitumen

TABLE 7A: RECOVER APPLICATIONS

SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOF COVER

Base Insulation Layer

Type

Min. 1.5-inch ACFoam II, FlintBoard,

ENRGY 3 or Multi-Max FA

Min. 0.25-inch Dens Deck primed

with FlintPrime or FlintPrime SA or

SECUROCK Gypsum-Fiber RoofBoard

Min. 1.5-inch ACFoam II, FlintBoard

ISO or ENRGY 3

Min. 0.25-inch SECUROCK Gypsum-

Fiber Roof Board

Min. 0.25-inch Dens Deck primedwith FlintPrime or FlintPrime SA

Min. 1.0-inch ISO 95+ GL, H-Shield,

H-Shield CG, ENRGY3 or min. 1.3-

inch ACFoam III,Min. 1.5-inch Multi-Max FA3 or Ultra-Max

Min. 1.0-inch ISO 95+ GL, H-Shield,

H-Shield CG, ENRGY 3 or min. 1.3-

inch ACFoam III, Min. l.S-inch Multi-

Max FA3 or Ultra-Max

Min. 0.25-inch SECUROCK Gypsum-

Fiber Roof Board

Min. 0.25-inch SECUROCK Gypsum-

Fiber Roof Board

Min. 0.25-inch SECUROCK Gypsum-

Fiber Roof Board

Min. 0.25-inch SECUROCK Gypsum-

Fiber Roof Board

Min. 0.25-inch SECUROCK Gypsum-

Fiber Roof Board

Attach

M-PGl

OB500

OB500

CR-20

CR-20

CR-20

CR-20

HA

A-PD, 6-

inch o.c.

A-PD, 6-

inch o.c.

M-PGl

OB500

Top Insulation Layer

Type

Min. 0.25-inch Dens Deck primed

with FlintPrime or FlintPrime SA

None

Min. 0.25-inch Dens Deck primed

with FlintPrime or FlintPrime SA or

SECUROCK Gypsum-Fiber Roof

Board

None

None

Min. 0.25-inch SECUROCK Gypsum-

Fiber Roof Board

Min. 0.25-inch Dens Deck primed

with FlintPrime or FlintPrime SA

None

None

None

None

None

Attach

M-PGl

N/A

OB500

N/A

N/A

CR-20

CR-20

N/A

N/A

N/A

N/A

N/A

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-59166

6 EDITION (2017) FBCNON-HVHZ EVALUATIONCertainTeed Flintlastic" Modified Bitumen Roof Systems; (610) 651-5847

Base

SBS-SA

SBS-SA

SBS-SA

SBS-SA

SBS-SA

SBS-SA

SBS-SA

SBS-SA-H

SBS-SA-H

SBS-SA-H

SBS-SA-H

SBS-SA-H

TRINITY ERD

Roof Cover (Note 14)

Ply

(Optional) SBS-SA

(Optional) SBS-SA

(Optional) SBS-SA

(Optional) SBS-SA

(Optional) SBS-SA

(Optional) SBS-SA

(Optional) SBS-SA

(Optional) SBS-AA,

SBS-TA, APP-TA

(Optional) SBS-AA,SBS-TA, APP-TA

(Optional) SBS-AA,

SBS-TA, APP-TA

(Optional) SBS-AA,

SBS-TA, APP-TA

(Optional) SBS-AA,

SBS-TA, APP-TA

Cap

SBS-SA

SBS-SA

SBS-SA

SBS-SA

SBS-SA

SBS-SA

SBS-SA

SBS-AA, SBS-

TA, APP-TA

SBS-AA, SBS-

TA, APP-TA

SBS-AA, SBS-

TA, APP-TA

SBS-AA, SBS-

TA, APP-TA

SBS-AA, SBS-

TA, APP-TA

MDP

(psf)

-180.0

-120.0

-120.0

-172.5

-192.5

-172.5

-192.5

-105.0

-105.0

-180.0

-180.0

-120.0

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 53 of 57

TRINITY ERDTABLE 7A: RECOVER APPLICATIONS

SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOF COVER

System

No.Substrate (Notes 1 & 11)

Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP

(psf)Type Attach Type Attach Base Ply Cap

R-24

Existing fully bonded, smooth- orgranule-surface BURor modifiedbitumen

Min. 0.25-inch SECUROCKGypsum-

Fiber Roof BoardCR-20 None N/A SBS-SA-H

(Optional) SBS-AA,SBS-TA, APP-TA

SBS-AA, SBS-

TA, APP-TA-195.0

Conventional Systems:

R-25Existing fully bonded BURormodified bitumen roof cover

0.5-inch Structodek High DensityFiberboard or min. 0.75-inch Fesco

Board (homogeneous)HA None N/A

BP-AA, SBS-

AA

(Optional) BP-AA,

SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-105.0

R-26Existing fully bonded BURormodified bitumen roof cover

0.25-inch Dens Deck, Dens Deck

Prime or SECUROCKGypsum-Fiber

Roof Board

HA None N/A

BP-AA, SBS-

AA, SBS-TA

or APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-105.0

R-27Existing fully bonded BURormodified bitumen roof cover

Min. 1.5-inch ACFoam II, FlintBoard

ISO, ENRGY3, H-Shield or Multi-Max

FA3

HA

Min. 0.5-inch Structodek HighDensity Fiberboard, Min. 0.75-inchFescoBoard (homogeneous) or Min.0.5-inch DuraBoard (homogeneous)

HABP-AA or

SBS-AA

(Optional) BP-AA,

SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-105.0

R-28Existing fully bonded BURormodified bitumen roof cover

Min. 1.5-inch ACFoam II, FlintBoard

ISO, ENRGY3, H-Shield or Multi-Max

FA3

HA

Min. 0.25-inch SECUROCKGypsum-Fiber Roof Board, Dens Deck, Dens

Deck Prime

HA

BP-AA, SBS-

AA, SBS-TA

or APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-105.0

R-29Existing fully bonded, smoothsurface BUR or modified bitumen

Min. 0.5-inch Structodek HighDensity Fiberboard

A-PD, 6-

inch o.c.None N/A

BP-AA, SBS-

AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-105.0

R-30Existing fully bonded, mineralsurface modified bitumen

Min. 0.5-inch Structodek High

Density FiberboardA-PD, 6-

inch o.c.None N/A

BP-AA, SBS-

AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-180.0

R-31Existing fully bonded, smoothsurface BUR or modified bitumen

Min. 0.25-inch Dens Deck, Dens

Deck Prime or SECUROCKGypsum-

Fiber Roof Board

A-PD, 6-

inch o.c.None N/A

BP-AA, SBS-

AA, SBS-TA

or APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-105.0

R-32Existing fully bonded, mineralsurface modified bitumen

Min. 0.25-inch Dens Deck, Dens

Deck Prime or SECUROCK Gypsum-Fiber Roof Board

A-PD, 6-

inch o.c.None N/A

BP-AA, SBS-

AA, SBS-TA

or APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-180.0

R-33Existing fully bonded, smoothsurface BUR or modified bitumen

Min. l.S-inch ACFoam II, FlintBoard

ISO, ENRGY 3 or H-Shield

A-PD, 6-

inch o.c.

Min. 0.5-inch Structodek High

Density FiberboardA-PD, 6-

inch o.c.

BP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-52.5

R-34Existing fully bonded, smooth

surface BUR or modified bitumen

Min. 2-inch ACFoam II, FlintBoard

ISO, ENRGY 3 or H-Shield

A-PD, 6-

inch o.c.

Min. 0.25-inch SECUROCKGypsum-

Fiber Roof Board or Dens Deck

A-PD, 6-

inch o.c.

BP-AA or

SBS-AA,

SBS-TA or

APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-52.5

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666thEDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic" Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19

Revision 20: 09/14/2017Appendix 1, Page 54 of 57

System

No.

R-35

R-36

R-37

R-38

R-39

R-40

R-41

R-42

R-43

R-44

R-45

Substrate (Notes 1 & 11)

Existing fully bonded, mineral

surface BUR or modified bitumen

Existing fully bonded, mineral

surface BUR or modified bitumen

Existing fully bonded BUR or

modified bitumen roof cover

Existing fully bonded BURormodified bitumen roof cover

Existing fully bonded, smooth- or

granule-surface BUR or modified

bitumen

Existing fully bonded, smooth- orgranule-surface BUR or modifiedbitumen

Existing fully bonded BUR or

modified bitumen roof cover

Existing fully bonded BUR or

modified bitumen roof cover

Existing fully bonded, smooth- or

granule-surface BURor modifiedbitumen

Existing fully bonded, smooth- or

granule-surface BURor modifiedbitumen

Existing fully bonded BUR or

modified bitumen roof cover

TABLE 7A: RECOVER APPLICATIONS

SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOF COVER

Base Insulation Layer

Type

Min. 1.5-inch ACFoam II, FlintBoard

ISO, ENRGY 3 or H-Shield

Min. 2-inch ACFoam II, FlintBoard

ISO, ENRGY 3 or H-Shield

Min. 1.5-inch ACFoam II, FlintBoard

ISO, ENRGY 3 or H-Shield

Min. 1.5-inch ACFoam II, FlintBoard

ISO, ENRGY 3 or H-Shield

Min. 0.5-inch Structodek High

Density Fiberboard

Min. 0.25-inch Dens Deck Prime or

SECUROCK Gypsum-Fiber Roof

Board

Min. 1.5-inch ACFoam II, FlintBoard

ISO, ENRGY 3 or H-Shield

Min. 1.5-inch ACFoam II, FlintBoard

ISO, ENRGY3 or H-Shield

Min. 0.5-inch Structodek High

Density Fiberboard

Min. 0.25-inch SECUROCK Gypsum-

Fiber Roof Board

Min. 1.5-inch ACFoam II, FlintBoard

ISO, ENRGY 3 or H-Shield

Attach

A-PD, 6-

inch o.c.

A-PD, 6-

inch o.c.

M-OSFA

M-OSFA

M-PGl

M-PGl

M-PGl

M-PGl

OB500

OB500

OB500

Top Insulation Layer

Type

Min. 0.5-inch Structodek High

Density Fiberboard

Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or Dens Deck

Min. 0.5-inch Structodek High

Density Fiberboard

Min. 0.25-inch SECUROCK Gypsum-

Fiber Roof Board or Dens Deck

None

None

Min. 0.5-inch Structodek High

Density Fiberboard

Min. 0.25-inch SECUROCK Gypsum-

Fiber Roof Board or Dens Deck

None

None

Min. 0.5-inch Structodek High

Density Fiberboard

Attach

A-PD, 6-

inch o.c.

A-PD, 6-

inch o.c.

M-OSFA

M-OSFA

N/A

N/A

M-PGl

M-PGl

N/A

N/A

OB500

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Base

BP-AA or

SBS-AA

BP-AA or

SBS-AA,

SBS-TA or

APP-TA

BP-AA or

SBS-AA

BP-AA or

SBS-AA,

SBS-TA or

APP-TA

BP-AA, SBS-

AA

BP-AA, SBS-

AA, SBS-TA

or APP-TA

BP-AA or

SBS-AA

BP-AA or

SBS-AA,

SBS-TA or

APP-TA

BP-AA, SBS-

AA

BP-AA, SBS-

AA, SBS-TA

or APP-TA

BP-AA or

SBS-AA

TRINITY erd

Roof Cover(Note 14)

Ply

(Optional) BP-AA,

S3S-AA, SBS-TA or

APP-TA

(Optional) BP-AA,

SBS-AA, SBS-TA or

APP-TA

(Optional) BP-AA,

SBS-AA, SBS-TA or

APP-TA

(Optional) BP-AA,

SBS-AA, SBS-TA or

APP-TA

(Optional) BP-AA,

SBS-AA, SBS-TA or

APP-TA

(Optional) BP-AA,

SBS-AA, SBS-TA or

APP-TA

(Optional) BP-AA,

SBS-AA, SBS-TA or

APP-TA

(Optional) BP-AA,

SBS-AA, SBS-TA or

APP-TA

(Optional) BP-AA,

SBS-AA, SBS-TA or

APP-TA

(Optional) BP-AA,

SBS-AA, SBS-TA or

APP-TA

(Optional) BP-AA,

SBS-AA, SBS-TA or

APP-TA

Cap

SBS-AA, SBS-

TA or APP-TA

SBS-AA, SBS-

TA or APP-TA

SBS-AA, SBS-

TA or APP-TA

SBS-AA, SBS-

TA or APP-TA

SBS-AA, SBS-

TA or APP-TA

SBS-AA, SBS-

TA or APP-TA

SBS-AA, SBS-

TA or APP-TA

SBS-AA, SBS-

TA or APP-TA

SBS-AA, SBS-

TA or APP-TA

SBS-AA, SBS-

TA or APP-TA

SBS-AA, SBS-

TA or APP-TA

MDP

(psf)

-172.5

-172.5

-127.5

-157.5

-180.0

-180.0

-180.0

-180.0

-120.0

-120.0

-120.0

Evaluation Report 3520.03.04-R20 for FL2533-R19

Revision 20: 09/14/2017Appendix 1, Page 55 of 57

TRINITY ERDTABLE 7A: RECOVER APPLICATIONS

SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOF COVER

System

No.Substrate (Notes 1 & 11)

Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP

(psf)Type Attach Type Attach Base Ply Cap

R-46Existing fully bonded BURormodified bitumen roof cover

Min. 1.5-inch ACFoam II, FlintBoard

ISO, ENRGY3 or H-ShieldOB500

Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board, Dens Deck or Dens

Deck Prime

OB500

BP-AA, SBS-

AA, SBS-TA

or APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-120.0

R-47

Existing fully bonded, smooth- orgranule-surface BURor modifiedbitumen

Min. 0.5-inch Structodek HighDensity Fiberboard

CR-20 None N/ABP-AA, SBS-

AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-195.0

R-48

Existing fully bonded, smooth- orgranule-surface BURor modifiedbitumen

Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

CR-20 None N/ABP-AA, SBS-

AA, SBS-TA

or APP-TA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-195.0

R-49Existing fully bonded BURormodified bitumen roof cover

Min. 1.0-inch ISO 95+ GL, H-Shield,

H-Shield CG, ENRGY3 or min. 1.3-

inch ACFoam III, Min. 1.5-inch Multi-

Max FA3 or Ultra-Max

CR-20Min. 0.25-inch Dens Deck or Dens

Deck PrimeCR-20 SBS-TA (Optional) SBS-TA SBS-TA -180.0

R-50Existing fully bonded BUR ormodified bitumen roof cover

Min. 1.0-inch ISO 95+ GL, H-Shield,

H-Shield CG, ENRGY3 or min. 1.3-

inch ACFoam III, Min. 1.5-inch Multi-

Max FA3 or Ultra-Max

CR-20

Min. 0.5-inch Structodek HighDensity Fiberboard or DuraBoard(homogeneous) or min. 1.5-inchFescoBoard (laminated)

CR-20BP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-180.0

R-51Existing fully bonded BURormodified bitumen roof cover

Min. 1.0-inch ISO 95+ GL, H-Shield,

H-Shield CG, ENRGY 3 or min. 1.3-

inch ACFoam III, Min. 1.5-inch Multi-Max FA3 or Ultra-Max

CR-20Min. 0.25-inch SECUROCKGypsum-

Fiber Roof BoardCR-20

BP-AA or

SBS-AA

(Optional) BP-AA,SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-225.0

R-52Existing fully bonded BURormodified bitumen roof cover

Min. 1.0-inch ISO 95+ GL, H-Shield,

H-Shield CG, ENRGY3 or min. 1.3-

inch ACFoam III, Min. l.S-inch Multi-

Max FA3 or Ultra-Max

CR-20Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

CR-20SBS-TA or

APP-TA

(Optional) SBS-TAor APP-TA

SBS-TA or

APP-TA-232.5

R-53Existing fully bonded BURormodified bitumen roof cover

Min. 1.0-inch ISO 95+ GL, H-Shield,

H-Shield CG, ENRGY3 or min. 1.3-

inch ACFoam III, Min. 1.5-inch Multi-

Max FA3 or Ultra-Max

CR-20 Min. 0.25-inch Dens Deck CR-20BP-AA or

SBS-AA

(Optional) BP-AA,

SBS-AA, SBS-TA or

APP-TA

SBS-AA, SBS-

TA or APP-TA-240.0

Cold-applied Systems:

R-54Existing fully bonded BURormodified bitumen roof cover

(Optional) Min. 0.5-inch ACFoam II,FlintBoard ISO, H-Shield, FlintBoard

ISOH

OB500

Min. 1.5-inch ACFoam III, FlintBoard

Iso Cold, H-Shield CG or FlintBoard

Iso ColdH

OB500 SBS-CAl None SBS-CAl -82.5

R-55Existing fully bonded BURormodified bitumen roof cover

(Optional) Min. 0.5-inch ACFoam II,FlintBoard ISO, H-Shield, FlintBoardISOH

CR-20

Min. l.S-inch ACFoam III, FlintBoard

Iso Cold, H-Shield CG or FlintBoard

Iso ColdH

CR-20 SBS-CAl None SBS-CAl -82.5

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2S33-R19Revision 20: 09/14/2017

Appendix 1, Page 56 of 57

TRINITY ERDTABLE 7A: RECOVER APPLICATIONS

SYSTEM TYPE A-l: BONDED INSULATION, BONDED ROOF COVER

System

No.Substrate (Notes 1 & 11)

Base Insulation Layer Top Insulation Layer Roof Cover (Note 14) MDP

(psf)Type Attach Type Attach Base Ply Cap

R-56

Existing fully bonded, smooth- or

granule-surface BURor modifiedbitumen

Min. 0.25-inch SECUROCKGypsum-

Fiber Roof Board

A-PD, 6-

inch o.c.None N/A SBS-CAl None SBS-CAl -105.0

R-57Existing fully bonded, smoothsurface BUR or modified bitumen

Min. 0.5-inch ACFoam II, FlintBoard

ISO, H-Shield, FlintBoard ISOH

A-PD, 6-

inch o.c.

Min. 0.25-inch SECUROCKGypsum-

Fiber Roof Board

A-PD, 6-

inch o.c.SBS-CAl None SBS-CAl -52.S

R-58Existing fully bonded, mineralsurface BUR or modified bitumen

Min. 0.5-inch ACFoam II, FlintBoard

ISO, H-Shield, FlintBoard ISO„

A-PD, 6-

inch o.c.

Min. 0.25-inch SECUROCKGypsum-

Fiber Roof Board

A-PD, 6-

inch o.c.SBS-CAl None SBS-CAl -105.0

R-59

Existing fully bonded, smooth- orgranule-surface BURor modifiedbitumen

Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

M-PGl None N/A SBS-CAl None SBS-CAl -105.0

R-60Existing futly bonded, mineral

surface BUR or modified bitumen

Min. 0.5-inch ACFoam II, FlintBoard

ISO, H-Shield, FlintBoard ISOH

M-OSFA,

M-PGl

Min. 0.25-inch SECUROCKGypsum-

Fiber Roof Board

M-OSFA,

M-PGlSBS-CAl None SBS-CAl -105.0

R-61

Existing fully bonded, smooth- orgranule-surface BURor modifiedbitumen

Min. 0.2S-inch SECUROCKGypsum-

Fiber Roof BoardOB500 None N/A SBS-CAl None SBS-CAl -105.0

R-62Existing fully bonded, mineralsurface BUR or modified bitumen

Min. 0.5-inch ACFoam II, FlintBoard

ISO, H-Shield, FlintBoard ISOHOB500

Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board

OB500 SBS-CAl None SBS-CAl -105.0

R-63

Existing fully bonded, smooth- or

granule-surface BURor modifiedbitumen

Min. 0.25-inch SECUROCK Gypsum-

Fiber Roof BoardCR-20 None N/A SBS-CAl None SBS-CAl -105.0

R-64Existing fully bonded, mineralsurface BUR or modified bitumen

Min. 0.5-inch ACFoam II, FlintBoard

ISO, H-Shield, FlintBoard ISOHCR-20

Min. 0.25-inch SECUROCKGypsum-

Fiber Roof BoardCR-20 SBS-CAl None SBS-CAl -105.0

TABLE7B: RECOVERAPPLICATIONS- NEW CONSTRUCTION or REROOF(Tear-Off)

SYSTEM TYPE F:NON-INSULATED, BONDED ROOF COVER

System

No.

Substrate

(Notes 1 & 11)Primer

Roof Cover (Note 14)MDP (psf)

Base Ply Cap

R-65 Existing fully bonded BURover structural concrete deck (Optional) FlintPrime (ASTM D41) SBS-CAl None SBS-CAl -187.5

Exterior Research and Design, LLC. d/b/a Trinity | ERDCertificate of Authorization #9503

Prepared by: Robert Nieminen, PE-591666™ EDITION (2017) FBC NON-HVHZ EVALUATION

CertainTeed Flintlastic* Modified Bitumen Roof Systems; (610) 651-5847

Evaluation Report 3520.03.04-R20 for FL2533-R19Revision 20: 09/14/2017

Appendix 1, Page 57 of 57