6,(0(16 - siemens2021. 8. 19. · 6,(0(16 ./ $ $ .$ $ $ 0rxqwlqj 'hwdlov fdo ,62 3 [ 3 [ 3 [ 3...

6
Assembly Required tools Operating Instructions SENTRON SUPERSWITCH Switch Disconnector Fuse - Size 1 SIEMENS 3KL81...-... (20A-100A) 3KA81...-... (63A-100A) Mounting Details: cal. ISO 6789 2P: 2x 3P: 3x 4P: 4x 2P: 4x 3P: 6x 4P: 8x 1x 3K.81... M6x14 8UC61.. 2P/3P: 2x 4P: 4x 3K.81... M4x20 For 3KL8 2P/3P 4P 104 Center of Shaft Contents Center of Shaft 2x 3K.81..-5 M6 x 14 2P/3P : M4 x 20 (2x) 4P : M4 x 20 (4x) Torque 1 to 1.5 Nm Last Update: June 2020

Upload: others

Post on 06-Sep-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Assembly

Required tools

Operating Instructions

SENTRON SUPERSWITCHSwitch Disconnector Fuse - Size 1

SIEMENS

3KL81... -... (20A-100A)3KA81...-... (63A-100A)

Mounting Details:

cal. ISO 6789

2P: 2x3P: 3x4P: 4x

2P: 4x3P: 6x4P: 8x

1x

3K.81... M6x14

8UC61..

2P/3P: 2x4P: 4x

3K.81... M4x20

For 3KL8

2P/3P 4P

104

Center ofShaft

Contents

Center ofShaft

2x

3K.81..-5M6 x 14

2P/3P : M4 x 20 (2x)4P : M4 x 20 (4x)Torque 1 to 1.5 Nm

Last Update: June 2020

Provision for Fuse monitoring

Hole M3

1

Connection

Assembly

L1V30606645001-01 | 02

Termination Details:

3KL8111../3KL8121../3KA8151.. 3KL8151../3KL8171../3KA8171..

Max. Lug Size .... 35 mm2 M6 x 14Torque 6 Nm to 7.5 Nm

M4 X 8 Torque 2 Nm.

Mounting of BS Fuse

(In the scope of supply)

Mounting Details for Front Drive 8UC6114-1BB00

Phase Barrier: 3KX81530AE

2P: Phase Barrier in positions 2 & 4 are essential3P: Phase Barrier in positions 2,3 & 4 are essential4P: Phase Barrier in positions 2,3,4 & 5 are essential

Assembly

L1V30606645001-01 | 03

2

183...240

Pane Door1.5....4Thk

Coupler

P4x11.51.1....1.3Nm

5.5+1-29+1-

Use Depth Setting Templet - 8UC6046-2

8UC Coupler depth adjustment

8UC 3K

3

2.5 mm

4

10 mm

Terminal cover2P/3P : 3KX81510AE4P : 3KX81510AG

White tag should be positionedtowards shaft

Mounting Aux. Switch 3SB54000A

Assembly

2P/3P : Additional Phase Barrier in position 1 & 5 4P : Additional Phase Barrier in position 1 & 6

Fuse Cover: 2P / 3P : 3KX81500AE

4P : 3KX81500AG

4

2

Assembly

Hazardous Voltage. Will Cause death or Serious Injury. Ensure Switch is in OFF postion. While mounting and removal.

2

1

3

1

Dimension Details for SDF in Enclosure

Overall Dimensional details

Information

Information

L1V30606645001-01 | 06 Product development is a continuous process. Consequently, the data indicated in this leaflet is subject to change without prior notice. For the latest issue contact our sales offices.

For Disposal, we recommend Disassembling and separation into following materials.

METALS. Segregate into Ferrous & Non Ferrous types for recycling through authorised dealer.

PLASTICS: Segregate as per material type for recycling through an authorised dealer.

Because of the long lifetime of Siemens products the disposal guidelines maybe replaced by other national regulations when taking the product out of service.

The local customer care service is available at any time to answer disposal-related questions

Siemens Products are environment-friendly, which predominantly consist of recyclable materials.

Customer Care Toll-free no. - 1800 209 0987Email: [email protected]

Mounting Dimensions

Outline of Enclosure

3KL8/3KA8 : 3P/3P+N

3KL8/3KA8 : 4P

MOUNTING HOLE(2x)

AUXLIARY SWITCHOFF POSITION

INDICATOR NEUTRALLINK

TERMINATIONTERMINALSHROUD

PHASEBARRIER

FUSECOVER

FOR SHAFTTIGHTING

120

81.5

MOUNTING HOLE(4x)

152.5

43.5 104

32.5

300

240

180

3010 190 25

30

For other dimensions refer 3P/3P+N For other dimensions refer 3P/3P+N

3KL8/3KA8 : 2P

43.5

120

43.5

14

13

12M6

26.1

49 32.5 29

160

136

23 2

100

95105

93106

91

16

7.5