60” Manhole Featuring “Easy Lift” on all manhole sections Top Unit Grade adjustment rings available in 2”, 4” & 6” Eccentric cones or flat top optional. Reducing flat top slabs are available for reducing to a 48” manhole or 24” opening for manhole frame and cover. Reinforcing - 0.12in ²/layer/LF minimum. Section Sections are available in heights of 1’ to 5’. All joints are designed for use with Rubber Gaskets. Steel Reinforced Polypropylene Steps and ladders are OSHA approved and installed as required. EZ Lift are provided for handling. Circumferential wall reinforcing is 0.30in ²/layer/LF minimum. Base Unit Base units are available in 2’ to 5’ heights. Reinforcing is 0.30in²/layer/LF minimum. All units meet or exceed ASTM C-478. Pipe Penetrations Cored holes or blockouts available as required. Maximum hole size is 48”. Minimum distance between holes is 8”. Note (1.) Joints use a Profile Gasket meeting ASTM C-443 Weights 60” x 2’ Base - 4565 lbs. Additional footage - 1323 lbs. per ft. 60” Sections - 1323 lbs. per ft. 60” x 8” Flat Slab Top - 2899 lbs. 60” x 3” Top Cone - 2600 lbs. 800-225-2539 www.psprecast.com 4.25” A 6’ -No Scale- All dimensions subject to allowable specification tolerances. 5’ 5’ WSDOT APPROVED

Upload: others

Post on 26-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • 60” Manhole Featuring “Easy Lift” on all manhole sections

    Top Unit Grade adjustment rings available in 2”, 4” & 6” Eccentric cones or flat top optional. Reducing flat top slabs are available for reducing to a 48” manhole or 24” opening for manhole frame and cover. Reinforcing - 0.12in ²/layer/LF minimum. Section Sections are available in heights of 1’ to 5’. All joints are designed for use with Rubber Gaskets. Steel Reinforced Polypropylene Steps and ladders are OSHA approved and installed as required. EZ Lift are provided for handling. Circumferential wall reinforcing is 0.30in ²/layer/LF minimum.

    Base Unit Base units are available in 2’ to 5’ heights. Reinforcing is 0.30in²/layer/LF minimum. All units meet or exceed ASTM C-478. Pipe Penetrations Cored holes or blockouts available as required. Maximum hole size is 48”. Minimum distance between holes is 8”. Note (1.) Joints use a Profile Gasket meeting ASTM C-443

    Weights 60” x 2’ Base - 4565 lbs. Additional footage - 1323 lbs. per ft. 60” Sections - 1323 lbs. per ft. 60” x 8” Flat Slab Top - 2899 lbs. 60” x 3” Top Cone - 2600 lbs.

    800-225-2539 www.psprecast.com

    4.25”

    A

    6’

    -No Scale- All dimensions subject to allowable specification tolerances.