alarmline linear heat sensor typical applications
TRANSCRIPT
Alarmline Linear Heat SensorTypical Applications
Alarmline Applications
• Heavy industry
• Warehousing / storage tanks
• Conveyors and escalators
• Cable trays
• Floor & ceiling voids
• Tunnels
• Car parks
Applications - Case Study 1 Electricity Generation
- Cable trays and risers
- Boiler fronts
- Conveyors
- Cooling towers
- Transformers.
Typical Cable Tray
End of line
To Junction Box
At end of tray Sensor Cableto be fixed to rear wall to
change levels
Cable Trays
Traywork width 600mm maximum
Alarmline cable
Powercables
Sensorsupports
AlarmLine
Cable Traywith Cables
Tray Support
Cable Flats
Typical Island Cable Tray
Transformers
• AlarmLine Recommendation:
– Nylon Coated AlarmLine
• Application Notes:
– Mount on Water Spray pipe around Main Body, Radiators & Oil Tank
Escalator Protection
Analogue Bronze braided orNylon coated cableDigital cable ofrequired temperature.
Sensor cable.Located under escalatorprotecting pits and roller bearings.
Dust collection pit
Dust collection / Drive motor pit
Typical Installation 2 lanetraffic road tunnel
ToControlPanel
JunctionBox
JunctionBox
Detection Cable(of specified temperature)
10
2.5 2. 5
5
Typical Car Park Installation
Control InterfaceUnit(Analogue)Junction Box(Digital)
9mtypical
Typical method of fixing sensor cable where beams are part of construction ‘T’ clips used.
1m Typically
Residential Car Park
Applications - Case Study 2Warehousing & Bulk Storage
- Alarmline Digital cable with conventional control unit or
- Alarmline Analogue high resistance / Nylon extruded cable with LHD 4 controller
- Fixing clips as required- “T” Clips- Edge connectors- Cable tray fixings.
Warehouse/High Rack Storage
PIPE
ALARMLINE SENSORAT CEILING LEVEL BACK TO BACK
RACKS
AISLE
AISLE
ALARMLINESENSOR SPRINKLER
PIPE
16’
ALARMLINE SENSORAT TOP RACK LEVEL
ATTACHED TO SPRINKLERTOP VIEW END VIEW
ChillerWarehouseApplication
Food Distribution
Racking
Alarmline Cable
Conveyor belt fire detectionAlarmline sensor cable installed directly at the support roller bearings location. This is to monitor what has been independently proven to be the greatest risk- an overheated condition generated by friction igniting the build up of material spilled from the belt. A wide range of clips and fastenings are available to match the environment and installation method.
Alarmline sensor cable can be installed directly over the conveyor to detect a fire/overheat on a stationary conveyor.
Bronze braided sensor cable is recommended as this provides greater protection against possible mechanical damage.
The Alarmline sensor cable should be run down both sides of the conveyor belt To give greater protection against build up of material under the bed of the conveyor Alarmline can be installed under the conveyor as shown in figure
LINEAR HEAT SENSORTypical installation on Single Conveyor
BEARING SUPPORT
SENSOR CABLE
OPTIONALSENSOR CABLE
Digital Sensor Cable mountedon conveyor bed plateand roller bearings(both sides of conveyor)
O ptional
A larm lineCable
Id le ro llers
Conveyor Belt
Conveyor return belt
Floating Roof Storage Tanks
• Install between primary & weather seal.
• Use Intrinsic Safety Barriers for Fuel related applications
Schematic diagram Alarmline Digital Linear Heat Sensor Protection Floating Roof Tank
JU N C TIO N BO X W ITHC ABLE C O LLEC TIN G ASSEM BLY
R ETR AC TABLE C ABLE
JU N C TIO N BO X
R IM SEAL
C O N TR O L C U BIC LELO C ATED IN SAFEAR EA
ZEN N ER BAR R IERC O M PARTM EN T
2 C O R E IN TER PO SIN G C ABLESU PPLIED AN D IN STALLED BY O TH ER S
SU PPO RT BR AC KETS
D IG ITAL LIN EARH EAT SEN SO RC ABLE AR O U N DR IM SEAL
TAN K
Typical Cable Schematic Diagram Alarmline DigitalNote: Resistors R1 & R2 supplied by panel manufacturer and fitted by others
1
H9650 LHS DigitalR1
EOL
B6782-044Retractable Cable
2 Core cableto controlPanel(by others)
1
2
3
4
1
2
2
4
3
B6782Junction Box
located onFixed Tank Top
B6782Junction Box
located onTank Floating Roof
R2
CableFitted toRim Seal
JU N C TIO N BO X W ITHC ABLE C O LLEC TIN G A S SE M BLYR ETR A C TAB LE C AB LE
JU N C TIO N BO X
R IM SEA L
C O N TR O L C U BIC LELO C ATED IN SA FEA R EA
ZEN N E R B AR R IERC O M PARTM EN T
4 C O R E IN TER P O SIN G C A BLES U PP LIED A N D IN S TA LLE D B Y O TH E R S
S U PP O RT BR AC KE TS
A LA R M LIN E LIN EAR H EATS EN S O R C ABLEA R O U N D R IM S EA L
TA N K
Schematic diagram Alarmline Analogue Linear Heat Sensor ProtectionFloating Roof Tank
Typical Connection Diagram Alarmline Analogue
Junction Box Tank Roof Top
1
2
3
4
5
6
7
8
Alarmline
Cable onTank
Junction BoxTank Top
1
2
3
4
Blue
Red
White
OrangeLink 2
Link 1
RetractableCable
4 Core Blue
Red
White
Orange
Detail showing collector installation typical
Bund Wall
Tank
3
7
HD Cable1
Typical Local Plan
1. LHD Cable2. LHD Mounting Piece S.S.3. Junction Box4. Mounting Bracket5. Cable Collector6. Flexicable7. Junction Box8. Mounting Bracket9. Neoprene Sleeve
10. Tie Wrap
Tank Mounting Detail
8
7 Tank
Foam Dam
6
5
3
1Cable CollectorFixed to Dam
Note:Retractable cable falls into collector not around centre section.
4
10
8
1
Site to confirmfixing arrangement
FoamDam
LHD Cable Mounting Detail
RIMSEAL RETAININGPLATE
3
2
1
4
6
5
JUNCTIONBOX
TANK WALL
INTERCONNECTING 4-CORE CABLE TO TANK LADDER
1
PART PLAN
RIM SEAL RETAINING PLATE
6
SHOWING CABLE TERMINATION INTO JUNCTION BOX
1. Edge Clip
2. M6 Nut, washer & bolt, St.St.
3. Distance piece, St. St.
4. Neoprene sleeve
5. Tywrap
6. Alarmline high resolution cable assembly
Note:
1. Maximum spacing between supports to be 1000mm
2. Alarm Cable to be terminated directly into Junction Box on cable Collector Drum which is to be secured adjacent to Rim Seal Protector Plate so the cable is not obstructed in its entry into Junction Box
RIM SEAL
400mm(NTS)
TANKWALL200mm
AlarmlineSensor
WeatherSeal
Tank WallFloating Roof
Retractable Cableto Tank TopJunction Box
EarthStrap
Tank Top
Typical Application without Foam Dam
500.0
100.0
200.0
4 HOLES25.0ON 400.00 PCD(FOR DRAINAGE)
4 HOLES25.0ON 300.00 PCD(FOR DRAINAGE)
620.
0
N um ber of C ores: 4C ore C olours: 1 B lue, 2 B row n, 3 B lack, 4 Ye llowC ore S ize: 0.75m m (24/.2)C ore Insu lation: H ytre lInner Sheath: PolyurethaneO uter Sheath: H ytre lLengths: 10-25m , 30 extended
2
230N om inal
340
Nom
inal
5000
1500
Fixed Roof Storage Tanks
• Install AlarmLine at 1 metre intervals on shell
• Use Intrinsic Safety Barriers for Fuel related applications
Dust Collectors/Bag Houses
Bag House - Top View
LHS SENSOR
Dust Collectors/Bag Houses
• Typical Hazards
– Grain and Feed Processing Facilities
– Fabric and Cotton Processing Facilities
– Metal Grinding/Polishing Facilities
– Wood Working Plants
• AlarmLine Recommendations
– Non-Abrasive: Nylon Coated
– Abrasive applications: Bronze Braided