EXTERNAL ALARM’S AT BTS SITE
AMIT MISHRA 2
INTRODUCTION
Alarm’s are used to monitor the site in case of any fault occur then
alarm panel automatically generate the alarm for corresponding fault occurred at site.
AMIT MISHRA 3
Why alarm’s are used at site?
External alarm is important at BTS site because in case of any fault occur then as a maintenance engineer it will be easier for us to identify the problem and rectify it accordingly. We can check at DDF, where termination of alarm is done. It provide security and stability to whole BTS site.
AMIT MISHRA 4
ALARM
BTSSITE
EXTERNAL
ALARM
INTERNAL
ALARM
TYPES OF ALARM AT BTS SITE
AMIT MISHRA 5
PARAMETER OF EXTERNAL ALARM
These are parameter which may differ according to manufacturer.
ALARM NO ALARM TYPE(NO/NC)
ALARM SEVERITYALARM PORT NO/PIN NO
COLOUR CODEROUTE
OF ALARM
ALARM NAME OR SYNTAX OR TITLE
ROOT CAUSE
OF ALARM
CAUSE OF ALARM
AMIT MISHRA 6
ALARM NAME OR SYNTAX OR TITLE
It define the name of the alarm at BTS site. It may differ according to the operator. Depending upon BTS used syntax or title can change. Some of the example of name of alarm operator are as follow’s..
BTS NAME ALARM NAME
NOKIA FLEXI BTS DG FAIL’S TO START MAIN’S FAILURE
ERICSSION RBS 2964 DG FAIL’S TO STOP DOOR OPEN
AMIT MISHRA 7
NORMALLY OPEN
NORMALLY CLOSED
PARAMETER DESCRIPTION CONTINUED
ALARM TYPE
ALARM NO
Every operator decide a particular alarm no for it’s BTS site and accordingly series of alarm is decided. for eg-7401 in NOKIA flexi BTS case.
ALARM TYPE
Type of alarm mean’s that either alarm will be normally Closed or normally open. Normally open mean’s that state of alarm in normal condition is OPEN. Normally closed mean’s that state of alarm in normal condition is closed.
AMIT MISHRA 8
PARAMETER DESCRIPTION
SE
VE
RIT
Y CRITICAL
MAJOR
MINOR
CRITICAL
Critical mean’s that ,it require immediate attention, if on BTS site any alarm is critical defined that mean’s that level of alarm severity is high. for eg : LLOP- low lubricant oil pressure.
MAJOR
Major mean’s that ,it’s severity level is lesser than critical but it is also needed attention as soon as possible. for eg: low fuel level
MINOR
Minor mean’s that ,it’s severity level is lesser in compare to other alarm and site may not get affected as much as in case of critical and major. for eg- site on DG.
AMIT MISHRA 9
PORT NO/PIN
NO
COLOUR CODE
OPERATOR
SPECIFIC
ALARM PORT
Alarm port or pin no is decided by operator itself .
COLOUR CODE
The colour code of alarm wire is decided by operator itself. Always it will exist in pair for PCM cable’s used.
AMIT MISHRA 10
ROUTE of
ALARM
• IT DECIDE ROUTE OF ALARM
ROOT CAUSE
• IT DECIDE THE CAUSE OF ALARM
ROUTE OF ALARM
It decide the route of alarm or we can say that where alarm connection start till termination of that alarm.
ROOT CAUSE
Root cause mean’s the exact cause of fault which led to the alarm at the site.
AMIT MISHRA 11
ALARM CABLE CONNECTION Alarm cable are PCM cable. They exist in pair’s. Each alarm will be connected to ddf with these cable.(two wire is one pair) 37 pin D-type connector. Alarm ddf installed on shelter wall. Alarm’s are connected to sensor’s.
25 PAIR PCM CABLE
AMIT MISHRA 12
DDF ALARM CONNECTION
D TYPE 37 PIN
For connection of alarm these are needed.
AMIT MISHRA 13
TYPE OF EXTERNAL ALARM’S 1. DOOR OPEN2. HIGH TEMPERATURE3. DG FAIL’S TO START4. DG FAIL’S TO STOP5. LOW FUEL LEVEL6. FIRE OR SMOKE7. LOW LUBRICATION OIL PRESSURE8. LOAD ON DG9. AC FAIL’S TO START(AC-1/AC-2)10.RECTIFIER MODULE PAIR FAIL’S11.LOW BATTERY VOLTAGE12.SITE ON DG13.AC -1 FAIL’S14.AC-2 FAIL’S15.DG RUNNING WITHOUT LOAD
AMIT MISHRA 14
TO ELABORATE ABOVE DESCRIPTION TAKE EXAMPLE OF NOKIA FLEXI BTS
There are 12 external alarm for nokia flexi BTS. For 12 alarm connection ,we need 37 pin D connector in which 24 pin’s will be used. For each alarm , we require one pair E1 cable having two wire. Termination of these cable is done on DDF i.e from BTS to DDF and from alarm sensor to DDF.
AMIT MISHRA 15
ALARM NO-7401/ALARM
NO1
SYNTAX-MAIN’S FAILURE
SEVERITY-MINOR
ALARM TYPE-NORMALY
OPEN
PIN NO-7/25
COLOR CODE-
GREEN&GREEN/WHITE
ROOT CAUSE -MAIN’S FAILURE
ROUTE OF ALARM PIU/AMF DDF BTS
AMIT MISHRA 16
ALARM NO-7402/ALARM
NO2
SYNTAX-RECTIFIER MODULEFAILURE
SEVERITY-MINOR
ALARM TYPE-NORMALY
OPEN
PIN NO-8/26COLOR
CODE-BLUE&BLUE/WHITE
ROOT CAUSE -RECTIFIER FAILURE
ALARM CONFIGURATION CONTINUED
ROUTE OF ALARM POWER PLANT DDF BTS
AMIT MISHRA 17
ALARM NO-7403/ALARM
NO3
SYNTAX-BATTERY AT 47V/LOW BATTERY
VOLTAGE
SEVERITY-CRITICAL
ALARM TYPE-NORMALY
OPEN
PIN NO-9/27
COLOR CODE-VOILET&WHITEVOILET
ROOT CAUSE -BATTERY VOLTAGE IS BELOW -48V
ALARM CONFIGURATION CONTINUED
POWER PLANT DDF BTS ROUTE OF ALARM
AMIT MISHRA 18
ALARM NO-7404/ALARM
NO4
SYNTAX-LOAD ON BATTERY
SEVERITY-MAJOR
ALARM TYPE-NORMALY
OPEN
PIN NO-10/28
COLOR CODE-GREY&
WHITE GREY
ROOT CAUSE -ALL RECTIFIER IN P.P FAILED
ALARM CONFIGURATION CONTINUED
POWER PLANT DDF BTS ROUTE OF ALARM
AMIT MISHRA 19
ALARM NO-7405/ALARM
NO5
SYNTAX-LOAD ON DG
SEVERITY-MINOR
ALARM TYPE-NORMALY
OPEN
PIN NO-11/29COLOR
CODE-PINK&BLACK/RED
ROOT CAUSE-MAIN’S FAILURE
ALARM CONFIGURATION CONTINUED
PIU/ AMF DDF BTS ROUTE OF ALARM
AMIT MISHRA 20
ALARM NO-7406/ALARM
NO6
SYNTAX-DG LLOP
SEVERITY-CRITICAL
ALARM TYPE-NORMALY
OPEN
PIN NO-12/30
COLOR CODE-LIGHTGREEN&
BLACK/GREEN
ROOT CAUSE-WHEN LUBRICANT OIL PRESSURE IN ENGINE GOES BELOW SPECIFIED LEVEL
ALARM CONFIGURATION CONTINUED
ROUTE OF ALARM PIU/AMF DDF BTSLLOP
SENSOR
AMIT MISHRA 21
ALARM NO-7407/ALARM
NO7
SYNTAX-LOW FUEL LEVEL
SEVERITY-MINOR
ALARM TYPE-NORMALY
OPEN
PIN NO-13/31COLOR
CODE-LIGHT BLUE&BLACK
ROOT CAUSE -WHEN THE FUEL IN TANK GOES BELOW 40%.
ALARM CONFIGURATION CONTINUED
ROUTE OF ALARMFUEL
SENSORPIU/AMF DDF BTS
AMIT MISHRA 22
ALARM NO-7408/ALARM
NO8
SYNTAX-DG FAIL TO START
SEVERITY-MAJOR
ALARM TYPE-NORMALY
OPEN
PIN NO-14/32
COLOR CODE-WHITE BLACK/WHIT
E
ROOT CAUSE-DG DOESN’T START AFTER 3 ATTEMPT’S BY PIU/AMF
ALARM CONFIGURATION CONTINUED
PIU/ AMF DDF BTS ROUTE OF ALARM
AMIT MISHRA 23
ALARM NO-7409/ALARM
NO9
SYNTAX-AC FAIL’S
SEVERITY-MAJOR
ALARM TYPE-NORMALY
OPEN
PIN NO-15/33
COLOR CODE-LIGHT GREY&LIGHT GREY
/BLACK
ROOT CAUSE-BOTH AC FAIL’S
ALARM CONFIGURATION CONTINUED
ROUTE OF ALARM-MICRO
CONTROLLER
DDF BTS
AMIT MISHRA 24
ALARM N0-7410/ALARM
NO10
SYNTAX-DOOROPEN
SEVERITY-MINOR
ALARM TYPE-NORMALY CLOSED
PIN NO-16/34
COLOR CODE-
GREEN&GREEN/WHITE
ROOT CAUSE -WHEN SHELTER DOOR IS OPEN.
ALARM CONFIGURATION CONTINUED
ROUTE OF ALARM- DOOR SENSOR
PIU/AMF DDF BTS
AMIT MISHRA 25
ALARM NO-7411/ALARM
NO11
SYNTAX-HIGH
TEMPERATUR-E
SEVERITY-MAJOR
ALARM TYPE-NORMALY
OPEN
PIN NO-17/35
COLOR CODE-ORANGE/
RED&ORANGE/LIGHT GREY
ROOT CAUSE -WHEN TEMPERATURE REACHES ALARMING LEVEL.
ALARM CONFIGURATION CONTINUED
ROUTE OF ALARM-MICRO
CONTROLLER DDF BTS
AMIT MISHRA 26
ALARM CONFIGURATION CONTINUED
ALARM NO-7412/ALARM
NO12
SYNTAX-FIRE/SMOKE
SEVERITY-CRITICAL
ALARM TYPE-NORMALY
OPEN
PIN NO-18/36
COLOR CODE-ORANGE
/BLACK&ORA-NGE/GREEN
ROOT CAUSE -WHEN TEMPERATURE REACHES ALARMING LEVEL.
ROUTE OF ALARM-FUEL
SENSORPIU/AMF DDF BTS
AMIT MISHRA 27
APART FROM THESE ALARM’S OF NOKIA FLEXI BTS WE HAVE FEW MORE AS FOLLOW’S
SYNTAX-DG FAIL’S TO
STOP
COLOUR CODE-
OPERATOR SPECIFIC
PIN NO-OPERATOR SPECIFIC
ALARM NO-OPERATOR SPECIFIC
ALARM TYPE-NORMALLY
CLOSED
SEVERITY-MINOR
PIU/AMF DDF BTS ROUTE OF ALARM-
ROOT CAUSE-WHEN PIU OR AMF NOT ABLE TO STOP DG AFTER 3 ATTEMPT.
AMIT MISHRA 28
SYNTAX-AC-1 FAIL’S
ALARM NO-OPERATOR SPECIFIC
COLOUR CODE-OPERATOR SPECIFIC
SEVERITY-MINOR
ALARM TYPE-NORMALLY
OPEN
PIN NO –OPERATOR SPECIFIC
APART FROM THESE ALARM’S OF NOKIA FLEXI BTS WE HAVE FEW MORE AS FOLLOW’S
MICRO CONTROLLER DDF BTS ROUTE OF ALARM-
ROOT CAUSE-WHEN AC-1 FAIL’S
AMIT MISHRA 29
SYNTAX-AC-2 FAIL’S
ALARM NO-OPERATOR SPECIFIC
COLOUR CODE-OPERATOR SPECIFIC
SEVERITY-MINOR
ALARM TYPE-NORMALLY
OPEN
PIN NO –OPERATOR SPECIFIC
APART FROM THESE ALARM’S OF NOKIA FLEXI BTS WE HAVE FEW MORE AS FOLLOW’S
MICRO CONTROLLER DDF BTS ROUTE OF ALARM-
ROOT CAUSE-WHEN AC-2 FAIL’S
AMIT MISHRA 30
LIST OF DIFFERENT OPERATOR EXTERNAL ALARM
Ericsson RBS2954 DG on DG fail’s to start Main fail’s DG fuel level LLOP DG fails to stop Cabinet temperature Fire & smoke Door smoke BFU fault Spare SMPS input fail Battery low voltage DC disconnected alarm Battery breaker off Battery disconnected
AMIT MISHRA 31
LIST OF DIFFERENT OPERATOR EXTERNAL ALARM
Ericsson RBS2964 DG on DG fail’s to start Main fail’s DG fuel level LLOP DG fails to stop Cabinet temperature Fire & smoke Door open BFU fault Spare SMPS input fail Battery low voltage DC disconnected alarm Battery breaker off Battery disconnected
AMIT MISHRA 32
LIST OF DIFFERENT OPERATOR EXTERNAL ALARM
HUAWEI 3900 Intruder A/C failure High room temperature Fire alarm Fire fighting Main’s failure Generator failure Generator run Rectifier high voltage Tower light failure Rectifier 2/more failure Tower amplifier fail Rectifier low voltage Rectifier common alarm GN auto mode Low fuel in main tank
AMIT MISHRA 33
LIST OF DIFFERENT OPERATOR EXTERNAL ALARM
ZTE ZXG 10
AMIT MISHRA 34
Sl. No External Alarms ID Breaking Closing Level1 DG ON 0 Closing 22 DG fail to Start 1 Closing 13 Mains Fail 2 Closing 14 High Shelter 3 Closing 1 Temperature5 DG Fuel Level Low 4 Closing 16 LLOP 5 Closing 27 DG Fail to Stop 6 Closing 18 Fire and Smoke 7 Closing 19 Door Open 8 Closing110 AC 1 - OFF 9 Closing 111 AC 2 – OFF A Closing 112 Spare B 13 Battery Fuse Fail C Closing 114 Rectifier Fail D Closing 115 Battery Low Voltage E Closing 116 SMPS Input Fail F Closing 1
ALARM DEFINED IN ERICSSON SITES:
AMIT MISHRA 35
Port ID External Alarms Closing/Breaking Level1 0 DG ON Closing 22 1 DG FAIL TO START Closing 13 2 MAINS FAIL Closing 14 3 DG FUEL LEVEL LOW Closing 15 4 LLOP Closing 26 5 DG FAIL TO STOP Closing 17 6 CABINET TEMPERATRE Closing 1 HIGH 8 7 FIRE AND SMOKE Closing 19 8 BBS DOOR OPEN Closing 110 9 BFU FAULT Closing 111 10 SPARE 12 B SMPS INPUT FAIL Closing 113 C BATTERY LOW VOLTAGE Closing 114 D DC DISCONNECTED ALARM Closing 115 E BATTERY BREAKER OFF Closing 116 F BATTERY DISCONNECTED Closing1
EXTERNAL ALARMS FOR BTS (RBS 2954) SITES:
AMIT MISHRA 36
S/N TTSL Requirement Node colour code1 AC mains fail blue-white2 High room temperature Orange-white3 fire alarm Green-white4 Battery Discharge Brown-white5 rectifier fail Blue-red6 intruder Orange-red7 DG low fuel Red-green8 DG running Brown-red
After we connect the cable on krone block we will give loop with krone tool one by one and check weather alarm get disappear in OMCR or not.Same way we have to check for all the 8 ports.
BELOW MENTIONED COLOUR CODE OF RBS(2954)-
AMIT MISHRA 37
EXTERNAL ALARM IN HUAWEI 3900 BTS AND COLOUR CODE-
KRONE NO:1 KRONE NO:2
NO: port SLOT DDF ALARM NO: port SLOT DDF ALARM
1 0 18 1 INTRUDER 9 0 19 1RECTIFIER
HIGH VOLTAGE
2 1 18 2 A/C FAILURE 10 1 19 2
TOWER LIGHT
FAILURE
3 2 18 3
HIGH ROOM
TEMPERATURE
11 2 19 3RECTIFIER 2/MORE FAILURE
4 3 18 4 FIRE ALARM 12 3 19 4
TOWER AMPLIFIE
R FAIL
5 4 18 5 FIRE FIGHTING 13 4 19 5
RECTIFIER LOW
VOLTAGE
6 5 18 6 MAINS FAILURE 14 5 19 6
RECTIFIER COMMON
ALARM
7 6 18 7GENERAT
OR FAILURE
15 6 19 7 GN AUTO MODE
8 7 18 8 GENERATOR RUN 16 7 19 8
LOW FUEL IN MAIN
TANK
AMIT MISHRA 38
HUAWEI EXTERNAL ALARMS(COLOURS)
EXTERNAL ALARM COLOUR CODES
CABLE NO: PAIR COLOUR
1 1 WHITE ORANGE
2 1 ORANGE
3 2 WHITE GREEN
4 2 GREEN
5 3 WHITE BLUE
6 3 BLUE
7 4 WHITE BROWN
8 4 BROWN
AMIT MISHRA 39
INSTALLATION OF ALARM AT OUTDOOR (AC/FAN COOLED) NOKIA BTS SITE
LIST OF ALARM’S (1)RECTIFIER & BTS DOOR CABINET ALARM(2)RECTIFIER MAJOR ALARM(3)RECTIFIER MINOR ALARM(4)LOW DC VOLTAGE(5)HEAT MANAGEMENT ALARM(FOR AC CABINET ONLY)(6)TEMPERATURE ALARM(FOR FAN COOL CABINE ONLY)
CORRESPONDING ALARM NO- ALARM NO1 ALARM NO2 ALARM NO3 ALARM NO4 ALARM N05 ALARM NO7
AMIT MISHRA 40
INSTALLATION OF ALARM AT OUTDOOR (AC/FAN COOLED) NOKIA BTS SITE
LIST OF COLOUR CODE OF ABOVE ALARM
ALARM NO1-RECTIFIER & BTS DOOR CABINET ALARM- GREEN & WHITE GREEN ALARM NO2-RECTIFIER MAJOR ALARM-BLUE & WHITE BLUE ALARM NO3-RECTIFIER MINOR ALARM-VIOLET & WHITE VIOLET ALARM NO4-LOW DC VOLTAGE-GREY & WHITE GREY ALARM NO5-HEAT MANAGEMENT ALARM(FOR AC CABINET ONLY)-BLUE/BLACK &BLACK BLUE ALARM NO7-TEMPERATURE ALARM(FOR FAN COOLED CABINET ONLY)-LIGHTBLUE &LIGHT BLUE/ BLACK
AMIT MISHRA 41
INSTALLATION OF ALARM AT OUTDOOR (AC/FAN COOLED) NOKIA BTS SITE
MATERIAL REQUIREMENT- ALARM CABLE KRONE RACK CAT-5 CABLE 7-9 METER SOLDERING IRON OTHRE BASIC TOOL’S
AMIT MISHRA 42
INSTALLATION OF ALARM AT OUTDOOR (AC/FAN COOLED) NOKIA BTS SITE
INSTALLATION PROCESS- Initial step before installation-
(1)Alarm cable is too long so cut it into two pieces.
(2)1st cable will be used to take alarm from rectifier smart pack i/o ports to crone.
(3)2nd cable with connector at one end will be used for taking alarms from krone to BTS EAC port(2G cabinet).
AMIT MISHRA 43
INSTALLATION OF ALARM AT OUTDOOR (AC/FAN COOLED) NOKIA BTS SITE
INSTALLATION PROCESS CONTINUE-
STEP-1 KRONE INSTALLATION
Install the krone on rack and fix this rack in rectifier cabinet. Use proper size bolt’s and washer.
AMIT MISHRA 44
Alarm cable installation(BTS – KRONE)
INSTALLATION PROCESS CONTINUE-
Connect the alarm cable connector on EAC port at BTS(2G cabinet) Bring the other end of alarm cable to rectifier through roxtec. Punch the alarm cable on the lower side of krone according to the alarm’s sequence. The alarm cable should be fixed properly with ties and properly routed.
AMIT MISHRA 45
INSTALLATION PROCESS CONTINUE-
Route this cable properly with ties and fix it near the Rectifier I/O ports
• Connect Green & White Green (Alarm nu 1) with Pins 8 & 9 of CON1
(X1)
• Connect Grey & White Grey (Alarm nu 4) with Pins 9 & 10 of CON2
(X2)
• Connect Violet & White Violet (Alarm nu 3) with Pins 15 & 16 of
CON2 (X2)
• Connect Blue & White Blue (Alarm nu 2) with Pins 18 & 19 of CON2
(X2)
• Connect Light Blue & Light Blue Black (Alarm nu 7) with Pins 12 & 13
of CON2 (X2) (Only for Fan Cool Rectifier Cabinets)
AMIT MISHRA 46
CON 2
( X2 )
CON 1
( X1 )
AMIT MISHRA 47
HEAT MANAGEMENT ALARM
INSTALLATION PROCESS CONTINUE-
Air condition in the door usuallyhas Red & Yellow cable for AirCondition Alarm. This cable is connected to Pins 3& 4 on CON1. Remove this cable from there &punch it on Krone.
AIR CON ALARM CABLE
AMIT MISHRA 48
Remove this cable from pins & punch it on Krone as shown
Air Con Alarm cable
INSTALLATION PROCESS CONTINUE-
AMIT MISHRA 49
To test Heat Management Alarm cover the AC from outside with plasticso that no air can go through as shown below
Air Condition covered with plastic sheet
TESTING HEAT MANAGEMENT ALARM-
INSTALLATION PROCESS CONTINUE-
AMIT MISHRA 50
900 BTS CABINET DOOR SENSOR
INSTALLATION PROCESS CONTINUE-
The BTS Cabinet door sensor cable is verysmall so we have to extend it•Take 1 pair from CAT-5 Cable and solderit with the sensor wires in BTS (900Cabinet)•Route this cable properly and fix it nearSmart Pack I/O ports•Connect this pair with pins 3 & 4 ofCON 2
BTS Cabinet doorSensor
AMIT MISHRA 51
INSTALLATION PROCESS CONTINUE-
RECTIFIER CABINET DOOR SENSOR
Usually Rectifier door Sensor cables are already connected to theCON 1 (X1)•
If it is not connected then connect Rectifier Door Alarm Cable withpins 1 & 2 of CON 1 (X1)
Rectifier Door cable connected topins 1 & 2 of CON 1
Rectifier Door Sensor
AMIT MISHRA 52
Overall summary is that on any BTS site external alarm’s are important. Alarm’s make fault finding easy. External alarm’s make BTS site safer and easy to maintain. Each alarm has it’s own importance cannot be neglected.