vlt® aqua drive - tlp equipment

Post on 03-Nov-2021

5 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

For applications such as lift stations, farming fields or any location where three-phase power is not available, UL-listed phase-converting VLT AQUA Drives can control three-phase motors using single-phase 240V or 480V service. Since three-phase motors are more readily available and less expensive, a variable frequency drive can be a cost-effective solution in these applications while providing an attractive alternative to conventional phase conversion devices. In addition, a drive provides numerous other benefits not available with traditional phase conversion units, including speed control, motor protection and energy savings.

Danfoss’ unsurpassed experience in advanced variable frequency drive technologies makes the VLT AQUA Drive the perfect choice for all water and wastewater applications. The first drive designed specifically for water and wastewater applications, the VLT AQUA Drive offers the most advanced technology and features available in the market.

Feature Benefit

Dedicated features•Modulardesign • Facilitatesmaintenanceandfieldupgrades• Six-lineLCPdisplay • Simultaneouslydisplaysmultipleparameters• IntegratedReal-TimeClock • Timestampingoffunctions/processcontrol• EnhancedSleepMode • Improvedenergysavings/processcontrol• InitialRamp • Performancethatmatchespumpdemands• Flowcompensation • Improvedsetpointcontrol• Endofpumpcurvedetection • Protectspump,detectsleakage•No/lowflowdetection • Pumpprotection• Pipefillmode • Eliminateswaterhammer• Pulsecounterwithtotalizer • VFDcanbeprogrammedtoshutdownata

predefined number of gallons used

Energy saving• VLTefficiencyof>98% •Optimizedperformance•AutomaticMotorAdaptation(AMA) •Optimalmotortuningwithoutspinning

motor shaft• AutomaticEnergyOptimization •Additional5–15%energysavings•Uniquecoolingconcept • Effectiveheatmanagement

Reliable• Shortcircuitandgroundfaultprotection • Preventsdamagetodrive• Lineormotorphaseimbalance

monitoring•Maintainsfulltorqueunderextreme

conditions•Overandundervoltageprotection • Protectsdriveandmotor•Overtemperaturemonitoring • Providesoperationcapabilitiesinextreme

temperatures• ElectronicThermalProtection • Protectsmotor•Optimumheatdissipation • Lengthensdrivelife• 100%factoryloadtesting • Ensureshighreliability•OptionalconformalcoatingonPCBs

available• Providesadditionalprotectioninharsh

environments

1.800.432.6367

VLT® AQUA DrivePhase conversion and speed control in a single, compact package

www.danfossdrives.com

Power range:

• 1-phase,200–240VAC:1.5–30HP

• 1-phase,380–480VAC:10–50HP

Enclosure ratings

•Available in Chassis, NEMA 1, NEMA 12 and outdoor-rated IP66 enclosures: designed either for mounting in existing panels or as standalone units

Available options

•Modular application options: plug-and-play cards facilitate drive upgrades, startup and servicing

• dV/dt filters:forprovidingmotorisolation protection

• Sine filters(LCfilters):reducemotornoise

PC software tools

•MCT10: provides powerful functionality for commissioning and servicing drives

•VLT Energy Box: comprehensive energy analysis tool

•MCT 31:harmonicscalculationtool

©Copyright2008byDanfossInc.5/08

Danfoss can accept no responsibility for possible errors in catalogs, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed. All trademarks in thismaterialarepropertyoftherespectivecompanies.DanfossandtheDanfosslogotypearetrademarksofDanfossA/S.Allrightsreserved.

www.danfossdrives.com

rev.NAMC.PB.A1.22 176R0626

Danfoss Drives8800W.BradleyRd.Milwaukee,WI53224,USAPhone: 1.800.621.8806 1.414.335.8800Fax: 1.414.355.6117

Mains supply (L1, L2, L3)Supply voltage 1-phase200–240V±10%;1-phase380–480V±10%

(UL-listed)Supply frequency 50/60HzDisplacementPowerFactor(cosφ)nearunity (>0.98)SwitchingoninputsupplyL1,L2,L3 1–2times/min.

Output data (U, V, W)Outputvoltage 3-phase200–240V;3-phase380–480VSwitching on output UnlimitedRamptimes 1–3600sec.Closedloop 0–132Hz

Digital inputs/outputsProgrammabledigitalinputs(standard) 6(twocanbeusedasdigitaloutputs)GeneralpurposeI/Ocard(option) 3additionaldigitalinputs,2additionaldigitaloutputsLogic PNPorNPNVoltage level 0–24VDC

Analog inputsAnaloginputs(standard) 2GeneralpurposeI/Ocard(option) 2 additional analog inputsAdvancedanalogI/Ocard(option)* 3additionalanaloginputsModes Voltage or currentVoltage level -10to+10V(scaleable)Currentlevel 0/4to20mA(scaleable)

Pulse inputsProgrammablepulseinputs(standard) 2(twoofthedigitalinputscanbeusedaspulseinputs)Voltage level 0–24VDC(PNPpositivelogic)Pulseinputaccuracy (0.1–110kHz)

Analog outputsProgrammableanalogoutputs(standard) 1GeneralpurposeI/Ocard(option) 1additionalanalogcurrentoutputAdvancedanalogI/Ocard(option)* 3additionalanalogoutputsCurrentrangeatanalogoutput 0/4-20mA

Relay outputsProgrammablerelayoutputs(standard) 2(240VAC,2Aand400VAC,2A)Relaycard(option) 3additionaldrycontactrelays(240VAC,FormC)Voltage level 0–24VDC(PNPpositivelogic)Pulseinputaccuracy (0.1–110kHz)

External DC supplyExternal24VDCsupplycard(option) Providesbackuppowerforcontrolandoptioncards

Fieldbus communicationFCProtocolandModbusRTUbuiltin(LonWorks,DeviceNet,ProfibusandEthernetIPmodulesoptional)

* Advanced analog I/O option card also provides 24V DC backup power for the VLT® AQUA Drive’s real-time clock.

top related