application of pulsed dc to suppress bubble incorporation & control deposit morphology during...

11
APPLICATION OF APPLICATION OF PULSED DC PULSED DC TO SUPPRESS TO SUPPRESS BUBBLE INCORPORATION & CONTROL DEPOSIT BUBBLE INCORPORATION & CONTROL DEPOSIT MORPHOLOGY DURING AQUEOUS ELECTROPHORETIC MORPHOLOGY DURING AQUEOUS ELECTROPHORETIC DEPOSITION (EPD) DEPOSITION (EPD) www.manuscriptedit. com Part Part - 2 - 2

Upload: manuscriptedit-docs

Post on 31-May-2015

72 views

Category:

Documents


2 download

DESCRIPTION

Application of pulsed dc to suppress bubble incorporation & control deposit morphology during aqueous electrophoretic deposition (epd)

TRANSCRIPT

Page 1: Application of pulsed dc to suppress bubble incorporation & control deposit morphology during aqueous electrophoretic deposition (epd) - Part - 2

APPLICATION OF APPLICATION OF PULSED DCPULSED DC TO SUPPRESS TO SUPPRESS BUBBLE INCORPORATION & CONTROL DEPOSIT BUBBLE INCORPORATION & CONTROL DEPOSIT

MORPHOLOGY DURING AQUEOUS MORPHOLOGY DURING AQUEOUS ELECTROPHORETIC DEPOSITION (EPD) ELECTROPHORETIC DEPOSITION (EPD)

www.manuscriptedit.com

Part - 2Part - 2

Page 2: Application of pulsed dc to suppress bubble incorporation & control deposit morphology during aqueous electrophoretic deposition (epd) - Part - 2
Page 3: Application of pulsed dc to suppress bubble incorporation & control deposit morphology during aqueous electrophoretic deposition (epd) - Part - 2

Objectives

Develop a generic aqueous EPD process applicable to all types of suspension and substrates by use of pulsed DC.

Control the extent of gas bubble incorporation and the morphology of the deposit.

Study and optimize the process parameters to obtain smooth, homogeneous and bubble-free deposits.

Develop understanding on the involved mechanism.

Page 4: Application of pulsed dc to suppress bubble incorporation & control deposit morphology during aqueous electrophoretic deposition (epd) - Part - 2

Experimental

Page 5: Application of pulsed dc to suppress bubble incorporation & control deposit morphology during aqueous electrophoretic deposition (epd) - Part - 2

Zeta potentialZeta potential

Page 6: Application of pulsed dc to suppress bubble incorporation & control deposit morphology during aqueous electrophoretic deposition (epd) - Part - 2

Constant voltage Continuous Constant voltage Continuous DC EPDDC EPD

Page 7: Application of pulsed dc to suppress bubble incorporation & control deposit morphology during aqueous electrophoretic deposition (epd) - Part - 2

Constant voltage Pulsed DC EPD

Page 8: Application of pulsed dc to suppress bubble incorporation & control deposit morphology during aqueous electrophoretic deposition (epd) - Part - 2

Conventional EPD process

Page 9: Application of pulsed dc to suppress bubble incorporation & control deposit morphology during aqueous electrophoretic deposition (epd) - Part - 2

Constant voltage Pulsed DC EPD

Page 10: Application of pulsed dc to suppress bubble incorporation & control deposit morphology during aqueous electrophoretic deposition (epd) - Part - 2

Constant voltage Pulsed DC EPD

Page 11: Application of pulsed dc to suppress bubble incorporation & control deposit morphology during aqueous electrophoretic deposition (epd) - Part - 2

APPLICATION OF APPLICATION OF PULSED DCPULSED DC TO SUPPRESS BUBBLE TO SUPPRESS BUBBLE INCORPORATION & CONTROL DEPOSIT MORPHOLOGY DURING INCORPORATION & CONTROL DEPOSIT MORPHOLOGY DURING

AQUEOUS ELECTROPHORETIC DEPOSITION (EPD)AQUEOUS ELECTROPHORETIC DEPOSITION (EPD) PART – 3 PART – 3 (Coming Soon) (Coming Soon)

THANK YOU

www.manuscriptedit.comwww.manuscriptedit.com

VISITVISIT