application of pulsed dc to suppress bubble incorporation & control deposit morphology during...
DESCRIPTION
Application of pulsed dc to suppress bubble incorporation & control deposit morphology during aqueous electrophoretic deposition (epd) Referneces :- * Aqueous electrophoretic deposition (epd) Part - 1 : http://goo.gl/aH06fC * Aqueous electrophoretic deposition (epd) Part - 2 : http://goo.gl/tu9F4Y * Aqueous electrophoretic deposition (epd) Part - 3 : http://goo.gl/hreKCr*TRANSCRIPT
APPLICATION OF APPLICATION OF PULSED DCPULSED DC TO SUPPRESS TO SUPPRESS BUBBLE INCORPORATION & CONTROL DEPOSIT BUBBLE INCORPORATION & CONTROL DEPOSIT
MORPHOLOGY DURING AQUEOUS MORPHOLOGY DURING AQUEOUS ELECTROPHORETIC DEPOSITION (EPD) ELECTROPHORETIC DEPOSITION (EPD)
www.manuscriptedit.com
Part - 4Part - 4
Mechanism
1.How the particles maintain electrophoretic mobility during pulse
OFF time.
2.Why the bubble incorporation decreases at lower pulse widths.
??
Mechanisms
Mechanism
Mechanisms
Pulsed EPD in High Magnetic Field
Pulsed EPD in High Magnetic Field
Pulsed EPD in High Magnetic Field
Anodic pulse EPD
Summary
Application of Pulse voltage/current of suitable width and duty cycle enabled smooth, bubble-free deposit by EPD
from aqueous suspension.
Yield from pulsed –EPD is generally less than continuous DC EPD. Yield decreases with decrease in pulse width.
A narrow window exists in the Voltage/current vs. pulse width plot within which bubble-free deposit is obtained.
There is no deposition at pulse widths below the window.
Deposit with incorporated bubbles form at pulse widths above the window.
The window is wider and lies at higher pulse widths for low applied potential/currents compared to higher
potential/currents.
Decrease in bubble incorporation at lower pulse widths is due to low discrete amount of H2 generation per pulse and
its uniform dissipation as micro and nano-bubbles which dont coalesce to form macro-bubbles.
Pulsed EPD will enable reduction in cost of EPD as it promises to use aqueous suspension and replace the
conventionally used organic solvents which are expensive and not environmental friendly.
Acknowledgements
Prof. Y. Sakka for giving me an opportunity to work in this Group.
Dr. T. Uchikoshi for being my host researcher.All the researchers in the group for their invaluable help and discussion.
Ms. Miki, Ms. Kon and Ms.Nakaizumi for help in experiments.
Ms. Tamiya & Ms. Yamaguchi for the administrative help.NIMS for the Post-doctoral fellowship.All the friends for making my time in Japan a memorable one.
APPLICATION OF APPLICATION OF PULSED DCPULSED DC TO SUPPRESS BUBBLE TO SUPPRESS BUBBLE INCORPORATION & CONTROL DEPOSIT MORPHOLOGY DURING INCORPORATION & CONTROL DEPOSIT MORPHOLOGY DURING
AQUEOUS ELECTROPHORETIC DEPOSITION (EPD)AQUEOUS ELECTROPHORETIC DEPOSITION (EPD)
THANK YOU
www.manuscriptedit.comwww.manuscriptedit.com
VISITVISIT