GEA Heat Exchangers / HVAC Systems

GEA Flex-Geko®

Solutions for all demands | Basic and Comfort

Lovely and flexible | Fan Coil Units

8/9/2019 A_VK_PR-2008-0305-GB_Flex-Geko_PB_K0-2008-09_150dpi1

http://slidepdf.com/reader/full/avkpr-2008-0305-gbflex-gekopbk0-2008-09150dpi1 2/16

Unlike radiators and classical flat radiators, fan coil units not

only can heat rooms, but can also cool and ventilate them.

With 2-litre units, seasonal switch-over from heating to cooling

operations is possible, and vice-versa (by reversing the medium

supply). The 4-litre units additionally offer connections for heat-

ing and cooling circulation systems, and therefore allow spon-

taneous change-over between the modes of operation.

Fan coil units actively direct the a ir to be t reated through the

heat exchanger, with especially effective heating or cooling. They

bring room air to the desired temperature faster and operate

 with smal ler heating or cooling surfaces. Their enhanced heat

transfer enables lower feed temperatures during heating, andhigher feed temperatures during cooling. This minimises losses

and saves energy between the boiler or the chiller and the final

unit.

A choice of fan speeds, as well as valves to regulate the flow vol-

ume, enable flexible control of unit output. Adjustable air-outlet

grills, in addition, assure uniform distribution of temperature-

controlled air in the room. Comfortable climate-control solution:

  Heating and cooling in one unit

  Assuring desired room temperature with smaller

units

  Energy saving with lower feed temperatures

during heating, and with higher temperatures for

cooling

  Flexible control

  Recirculated-air units in accordance with VDI

6022

GEA Flex Fan Coil Units

Heating, cooling, and ventilating –

fast and efficiently

 V D I  6 0 2 2

  (  D )

 S e a l  o f  h y

 g i e n e

 S W K I  VA

 

 1 0 4 - 0 1  (  C

 H )

       T    e     s      t   e   d

 

   r  o  o m

 -air  h  y g i   e  n  

e   

 

T   e  s  t  e d 

 b y 

 I L  H 

   B   E    R

      L       I    N

2 PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008

8/9/2019 A_VK_PR-2008-0305-GB_Flex-Geko_PB_K0-2008-09_150dpi1

http://slidepdf.com/reader/full/avkpr-2008-0305-gbflex-gekopbk0-2008-09150dpi1 3/16

The basic edition of the GEA Flex fan coil unit offers

reliable technology for many applications. This starter unit

is well suited for user-friendly heating and/or cooling, and

can be combined with various accessory components.

The Comfort Edition, with its distinctive light-grey band,

can climate-control rooms in mixed-air operation as well. It

can be equipped with an additional electrical heater ifrequired. Its various air-intake and -outlet directions

guarantee flow-optimised airflow routing for all applications.

The GEA Flex fan coil units are available in the Basic and Com-

fort Editions. Both of these variations are based on the same

equipment platform, and employ this platform with various sys-

tem components. This enables numerous equipment configura-

tions.

Purity and timeless design – the Basic variation

The Basic Edition model, with modest grey-white enclosure, con-

tains high-quality technology and offers (according to version)

connections for hot and/or cold water, a three-speed fan, and an

air filter. Various valve types allow coordinated and precise heat-

ing and cooling. With its extremely user-fr iendly control system,

the GEA Flex fan coil unit is therefore the perfect starter model

for comfortable, decentral climate control of your rooms.

Greater expectations in many variations –

the Comfort Edition

The Comfort Edition of the GEA Flex offers additional functions

and more features. It enables climate control of rooms in mixed-

air operation, and treatment of the air with finer filters. According

to the requirements, Comfort units offer hot and/or cold water con-nections. They can be equipped with additional electrical heating,

and with an integrated direct evaporator – which allows a combi-

nation with outdoor split-climate units. The enclosure is designed

for various air-intake and -outlet variations, and a light-grey band

makes the unit optically even slimmer.

Installation sizes and diversity of performance

Both GEA Flex variants, Basic and Comfort, are available in 8 in-

stallation sizes with a height beginning at 504 mm, and a uni-

form depth of 240 mm. The width wi ll vary according to output,

between 840 and 1,890 mm. The 8 unit sizes allow a selection

that optimally matches the required output. The heating and

cooling output ratings lie between 1 and 20 kW*. The circulat-

ing air volume coordinated to these output ratings varies be-

tween 150 and 1,800 m³/h.

Our models in the Basic and Comfort Editions

The right version for

every requirement

* Heating:  pumped hot water, 70/50°C, tL1 +20°C * Cooling:  pumped cold water, 6/12°C, tL1 +27°C, 46% relative humidity 

3PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008

8/9/2019 A_VK_PR-2008-0305-GB_Flex-Geko_PB_K0-2008-09_150dpi1

http://slidepdf.com/reader/full/avkpr-2008-0305-gbflex-gekopbk0-2008-09150dpi1 4/16

As a result of their modular concept, GEA Flex fan coil units

can be employed for many and various applications. These

models are effective with wall or ceiling installation. They

function highly satisfactorily on a stand-alone basis with en-

closure, or can be mounted virtually invisibly as base units,

 with the required air outlets , behind a wall or above a sus-

pended ceiling. The GEA MATRIX control system, integrated

as desired, adapts to each and every functionality. The opera-

tor control units – with or without integrated timer switches

– provide the interface to the user. The control units can be in-

stalled in the units themselves, or externally.

Flex units with primary-air connection can be easily combined with a central ventilation system. The control interfaces likewise

allow uncomplicated integration into the building-services man-

agement system.

GEA Flex fan coil units heat, cool, and ventilate offices, sales

rooms, and public facilities. Prominent hotel chains use them

gladly owing to their quiet and reliable operation. With their

cost-effective operation and flexible application possibilities,

GEA Flex fan coil units set standards for advanced climate-con-

trol solutions.

Satisfies virtually all requirements:

  Flexible setup and instal lation variations

  Integration possible behind walls or above

suspended ceilings

  The GEA MATRIX control system, adapted to

the required functionalities

  Integration into the building-services manage-

ment system via various interfaces

  Combination with other fan coil units or GEA

products

Equipped for virtually every use

With GEA Flex fan coil units, you can

flexibly plan for every application

4 PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008

8/9/2019 A_VK_PR-2008-0305-GB_Flex-Geko_PB_K0-2008-09_150dpi1

http://slidepdf.com/reader/full/avkpr-2008-0305-gbflex-gekopbk0-2008-09150dpi1 5/16

Wall and ceiling models

Comfort Edition

The Comfort Edition of GEA Flex fan coil

units satisfies requirements, for example,

in which mixed-air options are desired –

or where quiet heating and cooling are ex-

pected. They are also ideally suited for

cases in which exceptional installation sit-

uations prevail.

The many possible intake- and outlet-air

combinations, and the extremely quiet

fans, mean that Comfort Edition models

are something special. The possibility of

ordering these models with mixed-air op-

eration, and/or with electrical heating, ex-

pands their application spectrum. In ad-

dition, the great diversity of accessories

and the availability of various control

modules all mean that the Comfort Edi-

tion satisfies practically all situations.

Wall and ceiling models

Basic Edition

Already with the Basic Edition of GEA

Flex fan coil units, the most common re-

quirements for climate control of rooms

can be quietly and reliably satisfied.

These robust units are highly effective

for typical flush-mounted applications.

The Basic Edition has been designed for

heating or cooling in recirculated-air

mode. It is effective for all applications for

 which a standard flush-mounted situation

exists: for example, under windows. The

horizontal ceiling installation is ideally

suited, for example, for shops, workshops,

and other rooms where floor space is at a

premium.

Only recirculated-air operation

  Basic model shown here:

– without enclosure

  – ceiling version

  – four-pipe system

  – valves mounted

  Recirculated- or mixed-air operation

  Basic mixed-a ir model shown here:

– without enclosure

  – wall version

  – four-pipe system– valves mounted

5PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008

8/9/2019 A_VK_PR-2008-0305-GB_Flex-Geko_PB_K0-2008-09_150dpi1

http://slidepdf.com/reader/full/avkpr-2008-0305-gbflex-gekopbk0-2008-09150dpi1 6/16

Whether at home, at work, or in a hotel: GEA fan coil units

reliably assure feel-good room climate. High-performance fans

take the room quickly to the desired temperature, and quietly

maintain it at the required level.

With high-performance functions for feel-good climate

Basic or Comfort >   the requirement decides

[One equipment platform] [8 instal-lation sizes]  [2- and 4-pipe systems][150 – 1,800 m³/h]  [1 – 20 kW] 

[Heating, cooling, and ventilation]

6 PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008

8/9/2019 A_VK_PR-2008-0305-GB_Flex-Geko_PB_K0-2008-09_150dpi1

http://slidepdf.com/reader/full/avkpr-2008-0305-gbflex-gekopbk0-2008-09150dpi1 7/16

  Air intake on the narrow side; air outlet on the narrow

side. For recirculated-air operation with wall or ceiling

installation. Free air suction required approx. 10 cm

from the building. Without feet.

  Air intake on the narrow side; air outlet on the front

side. For recirculated-air operation with wall or ceiling

installation. Free air suction required approx. 10 cm

from the building. Without feet.

  Air intake on the front side; air outlet on the narrow

side. For recirculated-air operations with wall, ceiling,

or floor instal lation. For setup open in the room: with

optional back wall or narrow-side cover panel.

Intake-air opening with grill integrated into the

enclosure. Without feet.

  Air intake on the front side; air outlet on the front side.

For recirculated-air operations with wall, ceiling, or

floor installation. Intake-air opening with grill

integrated into the enclosure. Without feet.

  Air intake on the front side; air outlet on the narrow

side. For recirculated-air operations with wall, ceiling,

or floor installation. With feet – intake-air opening

 without gril l.

  Air intake on the front side – air outlet on the front

side. For recirculated-air operations with wall, ceiling,

or floor installation. With feet. Intake-air opening without gril l.

  Air intake on the front side – air outlet on the narrow

side. For recirculated- or mixed-air operations with

 wal l, cei ling, or floor insta llation. With feet. Mixed-air

intake opening integrated with grill. Intake of outside

air on the rear side, without grill.

  Air intake on the front side – air outlet on the front

side. For recirculated- or mixed-air operations with

 wal l, cei ling, or floor insta llation. With feet. Mixed-air

intake opening integrated with grill. Intake of outside

air on the rear side, without grill.

1

4

5 6

7 8

1

4

5

6

7

8

5 6 7 8

1 4

GEA Flex Fan Coil Units

Enclosures

7PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008

8/9/2019 A_VK_PR-2008-0305-GB_Flex-Geko_PB_K0-2008-09_150dpi1

http://slidepdf.com/reader/full/avkpr-2008-0305-gbflex-gekopbk0-2008-09150dpi1 8/16

If requested as option, the proven GEA MATRIX control unit will

be integrated into the GEA Flex fan coil units at the factory. Your

benefit: only completely tested equipment will be supplied to

 your construction site.

GEA MATRIX is available in configuration levels 500, 2000, 3000,

or 4000, with adaptation to the various possible applications. A ver-

sion can be supplied for hotel applications, for example: as well as

a Basic version for cost-optimised budgets.

Most of the versions are provided as default with the two-cable GEA

MATRIX dual-cable bus system, through which all GEA MATRIX

units can communicate with each other. As a result, it is simple to

implement daytime and nighttime switching actions, or to control

pumps and collect error messages at a single point. GEA MATRIX

can also be connected to higher-level bus systems.

In addition, GEA MATRIX assures energy-optimized operation of

GEA Flex fan coil units. A coordinated switch-over function, for

example, prevents heating and cooling circulation systems from

 working against each other. By means of the summer compensa-tion function, GEA MATRIX takes outside-temperature influenc-

es into account and prevents energy-intensive climate control.

Hardware and software are developed entirely at GEA. As a result

of close collaboration in the company, GEA engineers can system-

atically adjust the control system to match every component – and

in turn optimally exploit the possibilities of the fan coil units. GEA

support staff also profit from this arrangement by being able to

quickly and expertly react in case of any questions.

Numerous additional global modules are available as function ex-

pansions of the standard local connections. Examples here are: in-

tra-group GEA MATRIX control units and clock modules, modules

for activation control of exhaust-air fans and chillers, expansion of

analogue or digital input and output signals, 0 … 10-V outputs for

 valves, and integration into a LON bus system in accordance with

the LonWorks standard.

 

Starting with MATRIX 2000, all modules can be simply integrated

 via the MATRIX.Net bus system. In addition, the service tools

MATRIX.PDA and MATRIX.PC can be used for parameterisation,facility commissioning, maintenance, and data recording from the

MATRIX control system.

Comprehensive control possibilities:

Control functions in various expansion stages

  Bus interfaces to other equipment units

  Plug-and-play functionality 

  Energy-optimised equipment operation

  Equipment ready to operate

  Highly competent service

  Global add-on modules

  LON interface

  Service tool

GEA MATRIX – intelligent control technology

Just the right turn for

the right room climate

8 PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008

8/9/2019 A_VK_PR-2008-0305-GB_Flex-Geko_PB_K0-2008-09_150dpi1

http://slidepdf.com/reader/full/avkpr-2008-0305-gbflex-gekopbk0-2008-09150dpi1 9/16

MATRIX OP5

– Enclosure without display, pure white

– Recirculated-air mode,IP 20 protection class

– Desired-temperature setting

– Fan-speed selection for permanent duty

– Button for temperature-reduction mode

– LED for operation/malfunction/ext. inuence

– Integrated room-temperature sensor

MATRIX OP21

Same as the OP5 control unit, but with:

– Fan-speed selection switch forpermanent / automatic operation

– MATRIX.Net data bus  Network connection for MATRIX 

add-on modules via OP21 control unit

Control unit for MATRIX 500 Control unit for MATRIX 2000

Control units for MATRIX 3000 and MATRIX 4000

MATRIX OP50 without clockMATRIX OP51 with clock 

– Enclosure without display, pure white

– Recirculated-air / mixed-air modes of operation

– IP 20 enclosure protection class

– Operation by rotary navigator

– LCD display with plain text

– Status report by pictograms

– Integrated room-temperature sensor 

MATRIX.IR infrared remote control unit

– Funct ions as for the OP44 control unit, but:Without operational/malfunction reportsWithout report of external inuenceWithout integrated room sensor

– Black enclosure, similar to RAL 9004

– LCD display, 45 x 30 mm

– Effective range = approx. 20 m

MATRIX OP30 without buttons

MATRIX OP31 with temp.-reduction button 

– Enclosure without display, pure white

– Recirculated-air, IP 20 protection class

– Desired-temperature setting

– Fan-speed selection switch for permanent /automatic operation

– LED for operation/malfunction/ext. inuence

– Integrated room-temperature sensor

MATRIX OP44

Same as the OP31 control unit, but with:

– Selec tion switching for heating / cooling /automatic operation

– Selec tion switching for recirculated-air /mixed-air modes of operation

All units without display. Protective hood asoption.

GEA thermostat / compact switch units

CMS / CMT / CET series: extremely simple control units are also available for minimal control-function requirement s(for systems based on pumped hot water and pumped cold water).

9PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008

8/9/2019 A_VK_PR-2008-0305-GB_Flex-Geko_PB_K0-2008-09_150dpi1

http://slidepdf.com/reader/full/avkpr-2008-0305-gbflex-gekopbk0-2008-09150dpi1 10/16

  Air Heating CoolingBasic Edition Installed sizes flow rating ratingFan speeds 1 - 2 - 3 1 ... 8 in m3 / h in kW in kW

Recirculated air Typ Performance rating min | max min | max min | max

Pumped hot water / pumped cold water

Heating with pumped hot water U0W 180 | 1800 2.0 | 19.5

Cooling with pumped cold water UW0 180 | 1800 1.1 | 10.7

Cooling with pumped cold water or heating

with pumped hot water (change over)UWC

 180 | 1800 2.0 | 19.5 1.1 | 10.7

Cooling with pumped cold water and heating

with pumped hot water (4-pipe system)UWW

 175 | 1780 0.7 | 7.0 1.1 | 9.1

Overview of systems and performance ratings GEA Flex-Geko

See pages 12 and 13 for the output ratings in the individual fan-speed levels.

1

1

1

1

Heating with pumped hot water: 70/50°C, tL1 +20°C;

cooling with pumped cold water: 6/12°C, tL1 +27°C, 46% relative humidity; refrigerant: R410A, to +10°C ·

See page 11 for data on the sound emission

*The “U”s in the “Type” column above stand for recirculated air. “M” stands for mixed air

  Air Heating CoolingComfort-Edition Installed sizes flow rating ratingFan speeds 1 - 2 - 3 1 ... 8 in m3 / h in kW in kW

Recirculated air / mixed air Typ Performance rating min | max min | max min | max

Pumped hot water / pumped cold water

Heating with pumped hot water U0W / M0W 150 | 1820 1.7 | 19.6

Cooling with pumped cold water UW0 / MW0 150 | 1820 1.0 | 10.8

Cooling with pumped cold water or heating

with pumped hot water (change over)UWC / MWC

 150 | 1820 1.7 | 19.6 1.0 | 10.8

Cooling with pumped cold water and heating

with pumped hot water (4-pipe system)UWW / MWW

 145 | 1800 0.6 | 7.2 1.0 | 9.1

Pumped hot water / pumped cold water / electrical heating

Electrical heating U0E / M0E 270 | 1820 2.1 | 12.4

Heating with pumped hot water + 2.3 | 18.1

electrical booster heatingU0F / M0F

 220 | 1820

  0.9 | 

4.1

Cooling with pumped cold water or heating 2.3 | 18.1

with pumped hot water + electr ical heatingUWB / MWB 220 | 1820

  0.9 | 

4.11.2 | 9.6

Cooling with pumped cold water and

heating with electrical heating

UWE / MWE 220 | 1820 0.9 | 4.1 1.2 | 9.6

Cooling and heating with cold and hot water UWF 0.9 | 7.2

(4-pipe system) + electrical heating (only recirculated air)215 | 1800

0.9 | 

4.1  1.2 | 7.6

Refrigerant: R410A / pumped hot water

Cooling with R410A refrigerant UD0 / MD0 270 | 1820 1.2 | 

7.1

Cooling with R410A refrigerant and

heating with pumped hot waterUDW / MDW 270 | 1800 1.0 | 7.2 1.0 | 4.9

1

1

1

1

1

1

1

1

1

1

10 PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008

8/9/2019 A_VK_PR-2008-0305-GB_Flex-Geko_PB_K0-2008-09_150dpi1

http://slidepdf.com/reader/full/avkpr-2008-0305-gbflex-gekopbk0-2008-09150dpi1 11/16

Basic Edition – installed sizes 1 2 3 4 5 6 7 8Fan speeds 1 - 2 - 3

At air flow of: Fan speed 1 m3/ h 180 190 330 380 400 520 570 590

Acoustic power level Lw 33 33 33 35 35 36 36 36

Acoustic pressure level* Lp * 24 24 24 26 26 27 28 27

At air flow of: Fan speed 2 m3/ h 260 290 490 540 560 740 790 940

Acoustic power level Lw 41 43 44 44 44 44 45 45

Acoustic pressure level* Lp * 33 34 35 35 35 35 36 37

At air flow of: Fan speed 3 m3/ h 490 520 860 960 990 1310 1410 1800

Acoustic power level Lw 57 57 59 60 60 62 62 63

Acoustic pressure level* Lp * 48 49 51 51 51 54 53 54

GEA Flex-Geko Noise emission in dB(A)

* Conditions for measurement of acoustic pressure level Lp:

Measuring interval = 5 m. Room volume = 100 m³. Reverberation period = 0.5 s. Directional factor = 4 (quarter-sphere sound emission)

Comfort Edition – installed sizes 1 2 3 4 5 6 7 8Fan speeds 1 - 2 - 3 - 4 - 5

At air flow of: Fan speed 1 m3/ h 150 160 280 290 300 430 460 590

Acoustic power level Lw < 30 < 30 30 < 30 < 30 33 33 34

Acoustic pressure level* Lp * 21 < 20 21 20 < 20 24 24 25

At air flow of: Fan speed 3 m3/ h 270 280 470 490 520 750 770 970

Acoustic power level Lw 42 42 43 41 42 46 46 46

Acoustic pressure level* Lp * 33 33 34 32 34 38 38 37

At air flow of: Fan speed 5 m3/ h 530 540 890 990 1010 1310 1420 1820

Acoustic power level Lw 58 58 59 58 59 62 62 61

Acoustic pressure level* Lp * 50 49 51 50 51 54 53 53

11PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008

8/9/2019 A_VK_PR-2008-0305-GB_Flex-Geko_PB_K0-2008-09_150dpi1

http://slidepdf.com/reader/full/avkpr-2008-0305-gbflex-gekopbk0-2008-09150dpi1 12/16

Performance ratings Basic Edition

Basic Edition Installed size 1 2 3 4 5 6 7 8Capacity stage Min. fan-speed level = 1

2 pipes Air flow m3/ h 180 190 330 380 400 520 570 590

Heating U0W / UWC kW 2.0 2.3 3.6 4.3 4.7 5.6 6.3 6.8

Cooling UW0 / UWC kW  1.1 1.2 1.9 2.4 2.7 3.0 3.4 3.7

4 pipes Air flow m3/ h 175 185 325 370 390 515 565 585

Heating UWW kW 0.7 1.1 1.8 2.3 2.5 3.2 3.7 3.9

Cooling UWW kW  1.1 1.2 2.0 2.4 2.5 3.3 3.7 3.8

  Max. fan-speed level = 3

2 pipes Air flow m3/ h 490 520 860 960 990 1310 1410 1800

Heating U0W / UWC kW 3.8 4.6 6.7 7.9 8.8 10.5 11.6 14.3

Cooling UW0 / UWC kW  1.9 2.3 3.4 4.1 4.6 5.2 5.9 7.2

4 pipes Air flow m3/ h 485 515 850 945 975 1300 1395 1780

Heating UWW kW 1.4 1.9 3.0 3.7 4.2 5.3 5.9 7.1

Cooling UWW kW  1.9 2.2 3.5 4.2 4.4 5.7 6.3 7.2

1

Basic Edition Installed size 1 2 3 4 5 6 7 8Capacity stage Min. fan-speed level = 1

2 pipes Air flow m3/ h 175 185 325 370 390 515 565 585

Heating U0W / UWC kW 2.2 2.6 4.2 5.0 5.4 6.7 7.4 7.9

Cooling UW0 / UWC kW  1.2 1.5 2.3 2.8 3.2 3.5 4.1 4.5

4 pipes Air flow m3/ h 170 185 310 345 370 500 545 570

Heating UWW kW 0.9 1.2 1.9 2.2 2.5 3.0 3.4 3.7

Cooling UWW kW  1.1 1.4 2.1 2.6 2.9 3.3 3.7 4.1

  Max. fan-speed level = 3

2 pipes Air flow m3/ h 485 515 850 945 975 1300 1395 1780

Heating U0W / UWC kW 4.7 5.6 8.5 9.9 10.8 13.1 14.6 17.9

Cooling UW0 / UWC kW  2.4 3.1 4.4 5.4 6.0 6.8 7.7 9.6

4 pipes Air flow m3/ h 470 505 815 890 920 1255 1350 1700

Heizen UWW kW 1.6 2.2 3.3 3.9 4.4 5.1 5.8 7.0

Cooling UWW kW  2.2 2.9 4.2 5.0 5.6 6.4 7.3 9.1

2

Basic Edition Installed size 1 2 3 4 5 6 7 8Capacity stage Min. fan-speed level = 1

2 pipes Air flow m3/ h 170 185 310 345 370 500 545 570

Heating U0W / UWC kW 2.4 2.6 4.4 5.0 5.4 6.8 7.6 8 .1

Cooling UW0 / UWC kW  1.3 1.5 2.5 2.9 3.3 3.5 4.1 4.6

  Max. fan-speed level = 3

2 pipes Air flow m3/ h 470 505 815 890 920 1255 1350 1700

Heating U0W / UWC kW 5.2 6.0 9.4 10.6 11.6 14.3 15.8 19.5Cooling UW0 / UWC kW  2.9 3.3 5.2 6.0 6.5 7.6 8.6 10.7

3

Heating with pumped hot water: 70/50°C, tL1 +20°C; cooling with pumped cold water: 6/12°C, tL1 +27°C, 46% relative humidity

12 PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008

8/9/2019 A_VK_PR-2008-0305-GB_Flex-Geko_PB_K0-2008-09_150dpi1

http://slidepdf.com/reader/full/avkpr-2008-0305-gbflex-gekopbk0-2008-09150dpi1 13/16

Comfort Edition Performance ratings

Comfort Edition Installed size 1 2 3 4 5 6 7 8Capacity stage Min. fan-speed level = 1

2 pipes Air flow m3/ h 150 160 280 290 300 430 460 590

Heating U0W / UWC kW 1.7 2.0 3.2 3.5 3.7 4.9 5.4 6 .8

Cooling UW0 / UWC kW  1.0 1.1 1.7 2.0 2.1 2.6 2.9 3.7

4 pipes Air flow m3/ h 145 155 275 285 295 425 455 575

Heizen UWW kW 0.6 1.0 1.7 1.9 2.1 2.9 3.2 3.9

Cooling UWW kW  0.9 1.0 1.8 2.0 2.0 2.8 3.2 3.7

  Max. fan-speed level = 5

2 pipes Air flow m3/ h 530 540 890 990 1010 1310 1420 1820

Heating U0W / UWC kW 3.9 4.7 6.8 8.1 8.8 10.5 11.7 14.4

Cooling UW0 / UWC kW  2.0 2.4 3.4 4.1 4.7 5.2 5.9 7.3

4 pipes Air flow m3/ h 525 535 880 980 1000 1295 1405 1800

Heating UWW kW 1.4 2.0 3.1 3.7 4.2 5.3 5.9 7.2

Cooling UWW kW  2.0 2.3 3.5 4.3 4.5 5.7 6.4 7.3

1

Comfort Edition Installed size 1 2 3 4 5 6 7 8Capacity stage Min. fan-speed level = 1

2 pipes Air flow m3/ h 145 155 275 285 295 425 455 575

Heating U0W / UWC kW 1.9 2.2 3.7 4.0 4.3 5.7 6.2 7.8

Cooling UW0 / UWC kW  1.0 1.3 2.1 2.3 2.6 3.0 3.5 4.4

4 pipes Air flow m3/ h 145 155 265 280 290 415 445 545

Heating UWW kW 0.8 1.0 1.7 2.0 2.1 2.7 3.0 3.6

Cooling UWW kW  1.0 1.2 1.9 2.2 2.4 2.7 3.1 4.0

  Max. fan-speed level = 5

2 pipes Air flow m3/ h 525 535 880 980 1000 1295 1405 1800

Heating U0W / UWC kW 5.0 5.8 8.8 10.1 11.0 13.1 14.6 18.1

Cooling UW0 / UWC kW  2.5 3.1 4.5 5.5 6.1 6.8 7.8 9.6

4 pipes Air flow m3/ h 510 525 845 950 975 1245 1360 1710

Heating UWW kW 1.7 2.2 3.3 4.0 4.5 5.1 5.8 7.0

Cooling UWW kW  2.3 3.0 4.3 5.2 5.8 6.4 7.4 9.1

2

Comfort Edition Installed size 1 2 3 4 5 6 7 8Capacity stage Min. fan-speed level = 1

2 pipes Air flow m3/ h 145 155 265 280 285 415 445 545

Heating U0W / UWC kW 2.0 2.2 3.8 4.1 4.3 5.7 6.4 7.7

Cooling UW0 / UWC kW  1.2 1.3 2.2 2.4 2.6 3.1 3.4 4.4

  Max. fan-speed level = 5

2 pipes Air flow m3/ h 510 525 845 950 970 1245 1360 1710

Heating U0W / UWC kW 5.5 6.2 9.6 11.1 12.0 14.2 15.9 19.6Cooling UW0 / UWC kW  3.0 3.4 5.3 6.2 6.7 7.6 8 .7 10.8

3

Heating with pumped hot water: 70/50°C, tL1 +20°C; cooling with pumped cold water: 6/12°C, tL1 +27°C, 46% relative humidity.

Models with different output ratings are available upon request for systems with electrical heating and direct evaporators.

13PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008

8/9/2019 A_VK_PR-2008-0305-GB_Flex-Geko_PB_K0-2008-09_150dpi1

http://slidepdf.com/reader/full/avkpr-2008-0305-gbflex-gekopbk0-2008-09150dpi1 14/16

  Comfort Basic ComfortInstallat ion Recirculated air Mixed air weight weightsizes mm mm mm mm kg kg

  Height Height Width Depth Max Max

1  470 596 761 225 ... 237 13 18

2  470 596 911 225 ... 237 14 22

3  470 596 1061 225 ... 237 18 27

4  470 596 1211 225 ... 237  21 32

5  470 596 1361 225 ... 237 24 36

6  470 596 1511 225 ... 237 28 42

7  470 596 1661 225 ... 237 30 46

8  470 596 1881 225 ... 237 35 52

Base units – dimensions and weights (mass) GEA Flex-Geko

  Comfort Basic ComfortInstallat ion Recirculated air Mixed air weight weightsizes mm mm mm mm kg kg

  Height Height Width Depth Max Max

1  504 629 840 240 9 9

2  504 629 990 240 10 10

3  504 629 1140 240 11 11

4  504 629 1290 240 12 12

5  504 629 1440 240 13 13

6  504 629 1590 240 14 14

7  504 629 1740 240 15 15

8  504 629 1890 240 16 16

The dimensions of the recirculated-air unit with 125-mm supporting feet are the same as those of the mixed-air

unit.

Mixed air – Comfort Edition

Enclosures – dimensions and weights (mass)

The dimensions of the recirculated-air unit with 125-mm supporting feet are the same as those of the mixed-air

unit.

Wall units

Recirculated air – Basic andComfort

Without feet; without intake-

air grill

With feet; without intake-air

grill

EnclosuresBasic and Comfort Editions

Recirculated-air wall unit

Without feet; with intake-air grill

in the enclosure

With feet; without intake-air grill With feet; with intake-air grill

Air outlet on narrow side

With feet; with intake-air grill

Air outlet on front side

 EnclosuresComfort Edition

Mixed-air wall unit

 EnclosuresComfort Edition

Recirculated-air wall unit

With feet; with intake-air grill

1

5

7

4 6 7 8

471

225

225 (228**)

35

108

471

125

240

504

240

504

629

125

240

104504

629

125

240

120

92

504

504

629

125

240

120

504

629

125

240

104504

629

125

240

104

120

14 PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008

8/9/2019 A_VK_PR-2008-0305-GB_Flex-Geko_PB_K0-2008-09_150dpi1

http://slidepdf.com/reader/full/avkpr-2008-0305-gbflex-gekopbk0-2008-09150dpi1 15/16

Intake-air and outlet-air variations RecirculatedOutlet-air grill Outlet-air grillWall and ceiling models air-units of plastic of aluminium

Comfort•  I Basic ∆  For views, see page 7 Adjustable Not adjustable

Intake narrow side | Outlet narrow side

Intake narrow side | Outlet front side

Intake front side | Outlet narrow sideIntake front side | Outlet front side

Intake front side | Outlet narrow side | With cover panel

Intake front side | Outlet narrow side | With rear-wall panel

GEA Flex-Geko Enclosures without supporting feet

You are on this level of our documentation structure. You can order at no charge

from the first 3 levels as printed copies, under: info@gea-airtre atment.com.

You can download all brochures as PDF files from the following Internet site:

 www.ge a-air treatment.co m.

Application brochures

Image brochure

Product brochures

Data & Facts and operation manuals(available only as PDF)

41

2

3

4

3

3

Intake-air and outlet-air variations Mixed-air RecirculatedOutlet-air grill Outlet-air grillWall and ceiling models units air-units of plastic of aluminium

Comfort•  I Basic ∆  For views, see page 7 Adjustable Not adjustable

Intake front side | Outlet narrow side | Without intake grill

Intake front side | Outlet front side | Without intake grill

Intake front side | Outlet narrow side | With intake grill

Intake front side | Outlet front side | With intake grill

Enclosures with supporting feet

5

6

7

8

Air-intake side

Wall and ceiling models 

Comfort•  I Basic ∆ 

Intake-air box with primary-air ttings

Intake-air box with round intake fittings D N

200 enclosure cover for round ttings

Intake-air bend

Intake-air sailcloth ttings

Connection piece for intake-air sailcloth ttings

Intake-air telescopic ttings

Intake-air noise suppressor for recirculated-air

Intake-air noise suppressor for mixed-air units Built-

in wall frame for fresh-air ttings

Weather-protection grill, RAL 9002, painted

Built-in wall frame for weather-protection grill

Spare lter, G1

Spare lter, G2, G3

Outlet-air side

Wall and ceiling models 

Comfort•  I Basic ∆ 

Outlet-air box with primary-air ttings, not insulated 

Outlet-air box with primary-air ttings, insulated

Outlet-air box with round outlet-air t tings, not insulated

Outlet-air box with round outlet-air t tings, insulated

DN 200 enclosure cover for round ttings

Air-outlet bend, not insulated

Air-outlet bend, insulated

Outlet-air sailcloth ttings

Telescopic outlet-air ttings

Outlet-air noise-suppressor ttings

Accessories Accessories

15PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008