beer wort chart

Upload: ricardo-h-tomic

Post on 12-Jul-2015

43 views

Category:

Documents


0 download

TRANSCRIPT

Beer Wort Chilling by Plate Heat Exchanger Model Model B3-12A 10 Plate B3-12A 20 Plate B3-12A 20 Plate B3-12A 30 Plate B3-12A 30 Plate B3-12A 30 Plate B3-12A 40 Plate B3-12A 40 Plate B3-12A 40 Plate B3-23A 20 Plate B3-23A 20 Plate B3-23A 30 Plate B3-23A 30 Plate B3-23A 30 Plate B3-23A 50 Plate B3-23A 50 Plate B3-23A 50 Plate B3-32A 20 plate B3-32A 40 plate B3-32A 40 plate B3-32A 60 plate B3-32A 60 plate B3-32A 60 plate B3-32A 60 plate B3-52A 40 plate B3-52A 60 plate B3-52A 90 plate B3-95A 60 plate B3-95A 90 plate water (gpm) 5 5 10 5 10 15 5 10 15 5 7.5 5 7.5 10 5 10 15 15 20 25 20 25 30 35 25 31.6 46.7 51.3 76.5 Wort (gpm) 0.37 0.65 0.85 0.85 1.15 1.38 1 1.4 1.7 1.5 2 1.95 2.4 2.9 2.3 3.6 4.8 3 5.3 6 6.5 7.4 8.2 8.9 10.1 15.2 22.8 27.9 40.5 time for 10 Gal Batch (min) 27.03 15.38 11.76 11.76 8.70 7.25 10.00 7.14 5.88 6.67 5.00 5.13 4.17 3.45 4.35 2.78 2.08 3.33 1.89 1.67 1.54 1.35 1.22 1.12 0.99 0.66 0.44 0.36 0.25 Water Used (gal) 135 77 118 59 87 109 50 71 88 33 38 26 31 34 22 28 31 50 38 42 31 34 37 39 25 21 20 18 19

Chart assumes wort inlet temp of 212 F, water inlet of 68 F, and wort outlet of 75 F. Performance is estimated on best possible scenario, actual results may vary. Largest water flow given is the maximum recommended flow for that unit. www.dudadiesel.com

Beer Wort Chilling with Plate Heat Exchangers by Water Flow Rate Model B3-12A 10 Plate B3-12A 20 Plate B3-12A 30 Plate B3-12A 40 Plate B3-23A 20 Plate B3-23A 30 Plate B3-23A 50 Plate B3-23A 20 Plate B3-23A 30 Plate B3-12A 20 Plate B3-12A 30 Plate B3-12A 40 Plate B3-23A 30 Plate B3-23A 50 Plate B3-12A 30 Plate B3-12A 40 Plate B3-23A 50 Plate B3-32A 20 plate B3-32A 40 plate B3-32A 60 plate B3-32A 40 plate B3-32A 60 plate B3-52A 40 plate B3-32A 60 plate B3-52A 60 plate B3-32A 60 plate B3-52A 90 plate B3-95A 60 plate B3-95A 90 plate water (gpm) 5 5 5 5 5 5 5 7.5 7.5 10 10 10 10 10 15 15 15 15 20 20 25 25 25 30 31.6 35 46.7 51.3 76.5 Wort (gpm) 0.37 0.65 0.85 1 1.5 1.95 2.3 2 2.4 0.85 1.15 1.4 2.9 3.6 1.38 1.7 4.8 3 5.3 6.5 6 7.4 10.1 8.2 15.2 8.9 22.8 27.9 40.5 time for 10 Gal Batch (min) 27.03 15.38 11.76 10.00 6.67 5.13 4.35 5.00 4.17 11.76 8.70 7.14 3.45 2.78 7.25 5.88 2.08 3.33 1.89 1.54 1.67 1.35 0.99 1.22 0.66 1.12 0.44 0.36 0.25 Water Used (gal) 135 77 59 50 33 26 22 38 31 118 87 71 34 28 109 88 31 50 38 31 42 34 25 37 21 39 20 18 19

Chart assumes wort inlet temp of 212 F, water inlet of 68 F, and wort outlet of 75 F. Performance is estimated on best possible scenario, actual results may vary. Largest water flow given is the maximum recommended flow for that unit. www.dudadiesel.com

Beer Wort Chil ing with Plate Heat Exchangers by Wort Flow Model B3-12A 10 Plate B3-12A 20 Plate B3-12A 30 Plate B3-12A 20 Plate B3-12A 40 Plate B3-12A 30 Plate B3-12A 30 Plate B3-12A 40 Plate B3-23A 20 Plate B3-12A 40 Plate B3-23A 30 Plate B3-23A 20 Plate B3-23A 50 Plate B3-23A 30 Plate B3-23A 30 Plate B3-32A 20 plate B3-23A 50 Plate B3-23A 50 Plate B3-32A 40 plate B3-32A 40 plate B3-32A 60 plate B3-32A 60 plate B3-32A 60 plate B3-32A 60 plate B3-52A 40 plate B3-52A 60 plate B3-52A 90 plate B3-95A 60 plate B3-95A 90 plate water (gpm) 5 5 5 10 5 10 15 10 5 15 5 7.5 5 7.5 10 15 10 15 20 25 20 25 30 35 25 31.6 46.7 51.3 76.5 Wort (gpm) 0.37 0.65 0.85 0.85 1 1.15 1.38 1.4 1.5 1.7 1.95 2 2.3 2.4 2.9 3 3.6 4.8 5.3 6 6.5 7.4 8.2 8.9 10.1 15.2 22.8 27.9 40.5 time for 10 Gal Batch (min) 27.03 15.38 11.76 11.76 10.00 8.70 7.25 7.14 6.67 5.88 5.13 5.00 4.35 4.17 3.45 3.33 2.78 2.08 1.89 1.67 1.54 1.35 1.22 1.12 0.99 0.66 0.44 0.36 0.25 Water Used (gal) 135 77 59 118 50 87 109 71 33 88 26 38 22 31 34 50 28 31 38 42 31 34 37 39 25 21 20 18 19

Chart assumes wort inlet temp of 212 F, water inlet of 68 F, and wort outlet of 75 F. Performance is estimated on best possible scenario, actual results may vary. Largest water flow given is the maximum recommended flow for that unit. www.dudadiesel.com