[brochure] acti 9 communication system

Upload: yuris-immanuddin

Post on 14-Apr-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/30/2019 [Brochure] Acti 9 Communication System

    1/12

    Acti 9: The efciency you deserve

    Easily connect your switchboardsto acility management solutions

    Acti 9 communication system gives your customers

    complete control o their installations

    100%exclu

    siveto

    SchneiderElectric

  • 7/30/2019 [Brochure] Acti 9 Communication System

    2/12

    2

    Now we can monitor and controlpower consumption on each loor,production zone, oice unit, andworkshop in our site.

  • 7/30/2019 [Brochure] Acti 9 Communication System

    3/12

    3

    Its never

    been simpler

    to integrate

    electrical

    distribution

    into acility

    management

    systems

    A simple, powerul panel communication

    system like youve never seen beore

    Its communication

    system makes

    Acti 9 smart,

    ready-to-connect,

    ecient, and sae

    > Optimize energy consumption, enable energy efciency

    Collect and analyze data rom energy meters in each

    area, or each type o load or circuit

    Automate, schedule, and control operation o loads tooptimize energy consumption

    > Increase continuity o supply, power availability

    Get immediate, precise warning in case o power loss

    Make evolution o your installation quick and easy

    > Allocate costs

    Meter energy use, rom large areas or sectors to

    individual loads

    ... and its never been easier to connect!

  • 7/30/2019 [Brochure] Acti 9 Communication System

    4/12

    4

    > Smart

    Centralize control, collect energy meter data with just a simple, ready-to-connect communication module.

    Large diversity o data available to universal Modbus protocol.

    > EfcientOne-click, preabricated wiring or comprehensive communication between

    your distribution panel and any acility management system.

    > SaeReliable, error-proo manuacturer guaranteed connections

    EMC tested or immunity, radiated, and conducted saety.

    Acti 9 communication system

    Meets the challenge o all your applicationsInterior and exterior lighting, load monitoring, and cost allocation

    Protectionmonitoring

    Load controlswitching

    11 input/outputchannels

    Acti 9 Smartlink: the heart o the system Available only fromSchneider Electric

  • 7/30/2019 [Brochure] Acti 9 Communication System

    5/12

    5

    Ready to connect to any acility management solution

    Monitor and adjust specic loadsDetailed load control, reduced downtime, and

    accurately planned maintenance

    Energymetering

    Modbus network

    Modbus addressencoders

    24V DCpower supply

    Modbus RS-485connection

    Quick and easy

    control wiring

    enables complete

    control o your

    installation

    Energy

    managementsystem

    Programmablelogic

    controllers

    Building

    management

    system

    Internet

  • 7/30/2019 [Brochure] Acti 9 Communication System

    6/12

    6

    Unlike conventional distribution panels that require extensive wiring and

    communication cabling, Acti 9 integrates easily into any existing acility

    management system. Its fexibility reduces project and installation costs,

    and provides the most reliability, extendability, and upgradeability to your

    customers. With robust Modbus communication, the Acti 9 communication

    system can adapt to any uture developments, and becomes a key elementin your energy eciency strategies.

    As fexible, reliable, and extendable as you need it to be

    Plug and playAutomatic conguration o RS485

    at rst run connection

    Smart, and ready to be connected

  • 7/30/2019 [Brochure] Acti 9 Communication System

    7/12

    7

    Acti9Smartl inkauto-adapts,presentingclear,concisedata.

    Cancommunicatewithany24V-compatibledevices.

    Easy-to-readModbuscommunicationtablesstreamline

    commissioning.

    Open and universal

    100% compatibleFully compatible with any acility management system,

    control mode fexibility adapts easily to requirements

    Easy to integrate

    Designers candramaticallyreducebuildingdesignandinstallationcostswithoutdetailedwiring.

    Makesanypanelreconfigurationsimple.

    Daisychainconnectionsbetweenallyour

    switchboards,thankstoModbuscommunication.

    Reduce project costs with a simple, evolutive system

    Smart or system design

    Acti 9 revolutionizes communication indistribution panels

    Easilyaddanydeviceswhenitsneeded.

    Upgradeeasilytosuitanybuildingusage

    evolution.

    Designed for step-by-step investments

  • 7/30/2019 [Brochure] Acti 9 Communication System

    8/12

    8

    Easy control wiringwith one simple device

    the amount o

    time you save

    with the Acti 9

    communication system

    40%

  • 7/30/2019 [Brochure] Acti 9 Communication System

    9/12

    9

    Control wiring has never been sofexible and ast to implement

    No need or complex wiring or in/out terminal blocks crowding the switchboard. Acti 9 Smartlink has one-

    click, preabricated connectors or ast and easy data transmission support in your distribution panel.

    Most ecient or your timeEasy implementation and maintenance or

    maximum comort and peace o mind

    Eicient

    Maintenancepersonnelcan:

    Enjoylegible,easy-to-understand

    controlwiring.

    Confidentlyplanonsitemaintenancetimes.

    Schedule interventions,maintenance accurately

    Save time to operate and maintain

    Lesscontrolwiringandcabling

    Errorproofconnections

    Nointerfacerelays

    Automaticgenerationofas-builtcontrol

    descriptiondiagrams

    Save 40% o time spent oncontrol wiring

    Operatorscan:

    Viewreal-time,higher-resolut iondataon

    outgoers,tominimizedowntimeoneachcircuit.

    Instantlyfindthelocationoffaultyoutgoers.

    Performpreventivemaintenancetomaximize

    uptimewithinformationlikenumberofswitchings

    orrunninghoursforcontrolledloads.

    Improve power availability,decrease operations costs

  • 7/30/2019 [Brochure] Acti 9 Communication System

    10/12

    10

    Sae and reliableor the lietime o

    your installation

  • 7/30/2019 [Brochure] Acti 9 Communication System

    11/12

    11

    Complete peace o mind orthe lietime o your installation

    The Acti 9 communication system guarantees sae, reliable operation or the lietime o your

    installation. It is specically designed to integrate saely into nal distribution panels, and gives yourcustomers the greatest level o protection and control, even in demanding environments.

    WiththeActi9communication

    system,specialattentionwasgivento

    electromagneticcompatibility(EMC).

    Nomatterwhattypeofapplication,you

    cantrusttheintegrityofdata,andknow

    preciselywhatishappeningonyour

    circuitsatalltimes.

    Trust your installation status

    DesignerscantrustthatallActi9

    devicesarefullytestedandcompliant

    withindustryregulations.TheActi9communicationsystemisbasedon

    reliable24Vlow-levelcontactsthat

    guaranteedatatransmissionwillnot

    alterovertime.

    Guarantee data integrity forthe life of your installation

    Fully compliant60947-5-1, IEC 60947-5-4,

    IEC 61131-2

    EMC tested orimmunity, radiated,

    and conducted

    saety

    Absolutely sae

    A ully EMC-certifed

    communication system

    100% reliability

    The Acti 9

    communication

    system is high

    quality without

    compromise

  • 7/30/2019 [Brochure] Acti 9 Communication System

    12/12

    Smartfunctionsintegrated:

    Energy counting rom pulses

    Average power calculation

    Event counting

    Running hours

    Modbusprocessinginterfaceproviding:

    Circuit breaker status

    Energy meter output

    Contactor/impulse relay control

    and status

    2011SchneiderElectric.AllRightsReserved.SchneiderElectric,Acti9,andReflexaretrademarksowned

    bySchneiderElectricIndustriesSASoritsaffiliatedcompanies.Allothertrademarksarepropertyoftheir

    respectiveowners.Design: GlobalMarketing,CommunicationsStrategyandDesign998-4765_GMA

    Schneider Electric Industries SAS

    Head Ofce

    35rueJosephMonier

    92500RueilMalmaisonCedex-France

    Tel.:+33(0)141297000

    www.schneider-electric.com

    Introducing the Acti 9 communication system

    Circuit breaker auxiliary Pre-cabled links

    Energy meters

    Pre-cabled or error-proo connections

    Available in various lengths

    DIN rail mounted

    Designed or metering

    active energy consumed

    by a single- or 3-phase

    electric circuit

    Integrated control circuit breaker

    Circuit breaker remote control

    24VDC and 230 VAC

    Command-

    Open/closeposition-

    Trippingindication-

    Various confgurable local and

    remote control combinations

    Remote opening/closing o MCBs

    Remote control resetting ater tripping

    24VDC and 230VAC command

    and MCB position

    Various confgurable local/remote

    control combinations

    24V DC low-level contacts

    CB open/closed position-

    CB tripping indication-

    iOF+SD24,OF+SD24

    iEM2000TiEM3110

    ReexiC60 iATL24

    RCAiC60

    iACT24

    24V:

    Command to contactor-

    Open/closed contactor position-

    230V command to contactor

    Various confgurable local/remote-

    control combinations

    24V:

    Command to impulse relay-

    Open/closed impulse relay position-

    230V command to impulse relay

    Various confgurable local/remote-

    control combinations

    Contactor auxiliary

    Acti 9 Smartlink: The heart o the system

    Impulse relay auxiliary

    Available only from

    Schneider Electric