climate responsive design for administrative building in different climate zones in palestine

72
By : Bara Thaher Mohammad Sameer Osama Joma’a Supervisor : Dr Sameh Mona Climate Responsive Design For Climate Responsive Design For Administrative Building In Administrative Building In different climate zones in different climate zones in Palestine Palestine An-Najah National University Faculty of Engineering Building department 07/03/22 1

Upload: herrod-shaw

Post on 03-Jan-2016

17 views

Category:

Documents


2 download

DESCRIPTION

An-Najah National University Faculty of Engineering Building department. Climate Responsive Design For Administrative Building In different climate zones in Palestine. By : Bara Thaher Mohammad Sameer Osama Joma’a Supervisor : Dr Sameh Mona. O utline :. Project description - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Climate Responsive Design For Administrative Building In different climate zones in Palestine

By: Bara Thaher

Mohammad Sameer Osama Joma’a

Supervisor :Dr Sameh Mona

Climate Responsive Design For Climate Responsive Design For Administrative Building In different Administrative Building In different climate zones in Palestineclimate zones in Palestine

An-Najah National UniversityFaculty of Engineering

Building department

04/20/23 1

Page 2: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Project description

Methodology for solutions

Project design( Architectural , environmental , Structural , Mechanical, Electrical)

Recommendations for selection of environmental elements according to climate differences

Outline:

Page 3: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Our project is a redesign and suggestion of administrative building.

These type of buildings are important as it is used in many fields of usage in different climate zones such as .

The building designers establish these type of buildings without an overview to climate differences.

Project description Why administrative buildings:

Page 4: Climate Responsive Design For Administrative Building In different climate zones in Palestine

The employers of these type of buildings are not responsible for the energy bill, so they switch on the mechanical systems to reach their comfort zone.

This will cost the government

a lot of expenses.

Project description (cont.) Why administrative buildings:

Page 5: Climate Responsive Design For Administrative Building In different climate zones in Palestine

We considered education and higher education building in Tulkarm.

Project description (cont.)

Page 6: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Four floors and ground floor building and 256 m² for each floor.

East west orientation , and the entrance form east elevation .

Project description (cont.)

Page 7: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Orientation of the building east-west.

solar design is not taken

into consideration.

Consumes a large amount of

energy because there is a huge

amount of air conditioners

Project problems

Project description (cont.)

Page 8: Climate Responsive Design For Administrative Building In different climate zones in Palestine

The east elevation contain large glassing areas.

number of elevators is small compared

to the size of the building.

There are no emergency staircase.

No shading.

The parking capacity is not enough.

Project problems (cont.)

Page 9: Climate Responsive Design For Administrative Building In different climate zones in Palestine

we have divided building solutions into three categories to compare.

Category 1: existed building in Tulkarm.

Category 2: suggested solutions for the existed building in Tulkarm.

Category 3: the effect of climate diversity on the building.

Methodology for solutions.

Page 10: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Project design : Architectural solutions

Page 11: Climate Responsive Design For Administrative Building In different climate zones in Palestine

East elevation.

Project design : Architectural solutions (cont.)

Page 12: Climate Responsive Design For Administrative Building In different climate zones in Palestine

West elevation.

Project design : Architectural solutions (cont.)

Page 13: Climate Responsive Design For Administrative Building In different climate zones in Palestine

North elevation.

Project design : Architectural solutions (cont.)

Page 14: Climate Responsive Design For Administrative Building In different climate zones in Palestine

South elevation.

Project design : Architectural solutions (cont.)

Page 15: Climate Responsive Design For Administrative Building In different climate zones in Palestine

We used ECOTICT simulation program to analyze:

Day lighting levels.Thermal insulation.

We take a room in each elevation in existed and suggested buildings to be analyzed.

Project design : Environmental analyzing.

Page 16: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Daylight analysis:

Project design : Environmental analyzing (cont.)

Page 17: Climate Responsive Design For Administrative Building In different climate zones in Palestine

East room analysis in existed building.

%

23.2+

21.2

19.2

17.2

15.2

13.2

11.2

9.2

7.2

5.2

3.2

Daylight AnalysisDaylight FactorValue Range: 3.2 - 23.2 %© E C O T E C T v5

Visible Nodes: 48Average Value: 7.48 %

%

23.2+

21.2

19.2

17.2

15.2

13.2

11.2

9.2

7.2

5.2

3.2

Daylight AnalysisDaylight FactorValue Range: 3.2 - 23.2 %© E C O T E C T v5

Visible Nodes: 48Average Value: 7.48 %

Project design : Environmental analyzing (cont.)

Page 18: Climate Responsive Design For Administrative Building In different climate zones in Palestine

East room analysis in suggested building.

%

21.4+

19.4

17.4

15.4

13.4

11.4

9.4

7.4

5.4

3.4

1.4

Daylight AnalysisDaylight FactorValue Range: 1.4 - 21.4 %© E C O T E C T v5

Visible Nodes: 36Average Value: 3.73 %

Project design : Environmental analyzing (cont.)

Page 19: Climate Responsive Design For Administrative Building In different climate zones in Palestine

From the previous analysis, the output of ECOTICT program was as follow:

Project design : Environmental analyzing (cont.)

Page 20: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Thermal analysis

Using ECOTICT program, we analyzed the second floor in existed and suggested buildings, and extracted the simulation output.

Project design : Environmental analyzing (cont.)

Page 21: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Buildings thermal mass and walls layers.

Project design : Environmental analyzing (cont.)

Page 22: Climate Responsive Design For Administrative Building In different climate zones in Palestine

The existing and suggestion building have the same partition layers.

Project design : Environmental analyzing (cont.)

Page 23: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Types of window:

Project design : Environmental analyzing (cont.)

Page 24: Climate Responsive Design For Administrative Building In different climate zones in Palestine

We divide the second floor to four zone .

Project design : Environmental analyzing (cont.)

Page 25: Climate Responsive Design For Administrative Building In different climate zones in Palestine

The output from the analysis are shown in the following table:

Heating load comparison:

Cooling load comparison:

Project design : Environmental analyzing (cont.)

Page 26: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Solar chimney:

Project design : Environmental analyzing (cont.)

Page 27: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Solar window:

Project design : Environmental analyzing (cont.)

Page 28: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Shading:

Project design : Environmental analyzing (cont.)

Page 29: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Air conditions water disposal.

Project design : Environmental analyzing (cont.)

Page 30: Climate Responsive Design For Administrative Building In different climate zones in Palestine

we redesigned the existing building in Tulkarm according to the followings:

The American Concrete Institute code ACI 318-05.

The seismic design according to UBC-97.

The analysis and design were done using SAP2000 program.

Project design : Structural Analysis and Design

Page 31: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Design data : 1. Compressive strength :

f\c =24 Mpa2.Yielding strength of steel

The yield strength of steel for flexure Fy= 420Mpa. 3. Bearing capacity of soil

the bearing capacity of soil Qall.= 20Mpa.4. Slab thickness

One way ribbed slab is selected in design. The longest span (one end continues) = 4.55 m.The thickness of slab (h) = 455/18.5=24.6 cmwe used 25 cm as a thickness of slab.

Project design : Structural Analysis and Design (cont.)

Page 32: Climate Responsive Design For Administrative Building In different climate zones in Palestine

4.Beams dimension

5.columns dimensionGroup Dimension (mm)reinforcement

C1300*50012 14ɸ

C2300*60014 14 ɸ

type Dimension (mm)

Main beams250*550 drop 300*250

Secondary beams250*400

Edge beams300*400

Project design : Structural Analysis and Design (cont.)

Page 33: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Columns types and distribution

Project design : Structural Analysis and Design (cont.)

Page 34: Climate Responsive Design For Administrative Building In different climate zones in Palestine

• Compatibility check

3D Model Checks :

Project design : Structural Analysis and Design (cont.)

Page 35: Climate Responsive Design For Administrative Building In different climate zones in Palestine

• Maximum deflections

Project design : Structural Analysis and Design (cont.)

Page 36: Climate Responsive Design For Administrative Building In different climate zones in Palestine

ManualSAPError%

S.I.D11040105604.34 %

Live load369036830.27 %

• Equilibrium checks

Project design : Structural Analysis and Design (cont.)

Page 37: Climate Responsive Design For Administrative Building In different climate zones in Palestine

• Check participating mass ratio:

Project design : Structural Analysis and Design (cont.)

Page 38: Climate Responsive Design For Administrative Building In different climate zones in Palestine

• Slab moments from sap

Project design : Structural Analysis and Design (cont.)

Page 39: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Slab reinforcement

Project design : Structural Analysis and Design (cont.)

Page 40: Climate Responsive Design For Administrative Building In different climate zones in Palestine

• Reinforcement of a section in slab

Bottom steelTop steel

2ɸ18mm2ɸ12mm

Project design : Structural Analysis and Design (cont.)

Page 41: Climate Responsive Design For Administrative Building In different climate zones in Palestine

• Design of beams

Project design : Structural Analysis and Design (cont.)

Page 42: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Project design : Structural Analysis and Design (cont.)

Page 43: Climate Responsive Design For Administrative Building In different climate zones in Palestine

• Design of stairs

Project design : Structural Analysis and Design (cont.)

Page 44: Climate Responsive Design For Administrative Building In different climate zones in Palestine

• Design of footings

GroupFooting dimension(B*L*H) m

Footing reinforcement

F1(2.00*1.80*0.35) 9 14 long directionɸ

10 14 short directionɸ

F2(2.20*2.00*0.35) 12 14 long directionɸ

13 14 short directionɸ

Project design : Structural Analysis and Design (cont.)

Page 45: Climate Responsive Design For Administrative Building In different climate zones in Palestine

• Reinforcement of the windows

Project design : Structural Analysis and Design (cont.)

Page 46: Climate Responsive Design For Administrative Building In different climate zones in Palestine

• Elevator System Design.

• Water Supply Systems.

• Drainage Water Systems Design.

• HVAC System Design.

Project design : Mechanical design

Page 47: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Elevator System Design. After making calculations for the required elevators

the result was:

The elevator type is motor driven elevator with a sliding door we use 2 elevator type (2500/350)

Project design : Mechanical design (cont.)

Page 48: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Water Supply Systems. we took the third floor as sample of

calculations :

• we use 1.5’’ for main vertical cooled Pipe

• We used 1’’ for main vertical heat Pipe We used 1.25'' for main horizontal

cooled pipe

Project design : Mechanical design (cont.)

Page 49: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Water Supply Systems (cont.)

•We used 3/4 for main horizontal heat

• We used 3/8'' for sink.

• We used 3/8 '' for flush tank.

Project design : Mechanical design (cont.)

Page 50: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Water Supply Systems (cont.)

Project design : Mechanical design (cont.)

Page 51: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Drainage Water Systems Design.

After doing calculation for plumbing system we used for: • stack diameter 4’’.

• Lavatory pipe diameter 2’’.

• floor drain pipe diameter 3’’.

• Sewage Manholes pipe 4’’.

• Dischage pipe 4’’

Project design : Mechanical design (cont.)

Page 52: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Drainage Water Systems Design (cont.)

Project design : Mechanical design (cont.)

Page 53: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Drainage Water Systems Design (cont.)

Project design : Mechanical design (cont.)

Page 54: Climate Responsive Design For Administrative Building In different climate zones in Palestine

DISCHAGE PIPE:

Project design : Mechanical design (cont.)

Page 55: Climate Responsive Design For Administrative Building In different climate zones in Palestine

•HVAC System Design.Form ECOTICT, results of heating and

cooling load for the zone as flow :

: First zoneSecond zoneThird zoneFourth zone

Heating load 6360410354412501

Cooling load 13972126872996825046

Project design : Mechanical design (cont.)

Page 56: Climate Responsive Design For Administrative Building In different climate zones in Palestine

•HVAC System Design (cont.).We use cooling load to design and diffuser which diffuse 400 CFM for room and other diffuse 200 CFM for Corridor . We use Design Tools Ducts Size Version

6.4 to find duct size .

Project design : Mechanical design (cont.)

Page 57: Climate Responsive Design For Administrative Building In different climate zones in Palestine

•HVAC System Design (cont.).

Cooling load

First zone 13.9724

Second zone 12.6874

Third zone 29.9889

Furth zone 26.0647

Project design : Mechanical design (cont.)

Page 58: Climate Responsive Design For Administrative Building In different climate zones in Palestine

•HVAC System Design (cont.).

Project design : Mechanical design (cont.)

Page 59: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Lighting Design:

we used lumens method to find required number of lighting units.

Used (F14T12) lighting unitsThe required lumens for offices 500 lux.For corridor 100 lux.For bath room 120 lux.Workplace height is 60 cm

Project design : Project design : Electrical designElectrical design . .

Page 60: Climate Responsive Design For Administrative Building In different climate zones in Palestine

We will take planning room sample of calculation diminutions (4.3*3.8*2.4)m

Reflection coefficient of the roof = 70%Reflection coefficient of the wall = 50%E=500 LuxF100T17------------Flux =4750Lum useKr = (L*W)/(Hm*(L+W))=(3.8*4.3)/(2.4*(3.8+4.3))Kr =0.8Uf=.35Df=LLD*LDD*RSDD------------- Clean

.85.*85.*85.= 61= DFE=(n*f*uf*df)/(A)

500( = n * 4750 *.35 * 0.61\)15.9N= n\4 = 15.15\4 = 4 Laminar

Project design : Project design : Electrical designElectrical design . .

Page 61: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Project design : Project design : Electrical designElectrical design . .

Page 62: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Project design : Project design : Electrical designElectrical design . .

Page 63: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Project design : Project design : Electrical designElectrical design . .

Page 64: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Project design : Project design : Electrical designElectrical design . .

Electrical load

Page 65: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Project design : Project design : Electrical designElectrical design . .

Electrical load

Page 66: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Project design : Project design : Electrical designElectrical design . .

Electrical load

Page 67: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Project design : Project design : Electrical designElectrical design . .

DIAlux:

Page 68: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Project design : Project design : Electrical designElectrical design . .

DIAlux:

Page 69: Climate Responsive Design For Administrative Building In different climate zones in Palestine

After analysis and study we found out recommended choices for environmental elements for buildings according to their climate diversity as follows:

Orientation

JerichoNablusTulkarmorientationSouth-northSouth-northSouth-north

Recommendations for selection of Recommendations for selection of environmental elements according to climate environmental elements according to climate differencesdifferences

Page 70: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Recommendations for selection of Recommendations for selection of environmental elements according to climate environmental elements according to climate differences (cont.)differences (cont.)

ShadingJerichoNablusTulkarm

ShadingFull shadingIn summerIn summer

Thermal Mass

JerichoNablusTulkaremThermal massLowerHigherModerateInsulationLowerHigherModerate

Page 71: Climate Responsive Design For Administrative Building In different climate zones in Palestine

ventilationJerichoNablusTulkarm

ventilationMechanical and natural

Naturalnatural

openings

JerichoNablusTulkarmLarge opening in:

No large openings

North and southNorth and south

height to widthheight >> widthheight => widthheight => width

Recommendations for selection of Recommendations for selection of environmental elements according to climate environmental elements according to climate differences (cont.)differences (cont.)

Page 72: Climate Responsive Design For Administrative Building In different climate zones in Palestine

Heating and cooling to be designed

Shape of building

JerichoNablusTulkarmShapeSquare with core

insideSquarerectangular

JerichoNablusTulkarmHeatingNot to be

designedTo be designedTo be designed

CoolingTo be designedTo be designedTo be designed

Recommendations for selection of Recommendations for selection of environmental elements according to climate environmental elements according to climate differences (cont.)differences (cont.)