Doc Id: AS/NZS 60598.2.2 Page 1 of 8 Report No.: 1104EFFLED_59822 Accredited for compliance with ISO / IEC 17025. Approval Specialists Pty. Limited (ACN: 094 656 354) Trading as Austest Laboratories Compliance Testing Report for Australian/New Zealand Standards AS/NZS 60598.1:2003 and AS/NZS 60598.2.2:2001 Luminaires Part 2.2: Particular Requirements — Recessed Luminaires (Limited Testing Only) Client: Efficiency Matrix Address: 14 Ondine Drive, Wheelers Hill, Victoria 3150 Report Number: 1104EFFLED_59822 (Replacement for report no. 1030EFFLED_59822) Date of Testing: 29 – 30 October 2009 File Number: EFF091022 Equipment Name: LED Mitt Equipment Model Number: Ledmitm2 Equipment Description: LED Mitt Result: COMPLIES Tested by: Hai Ying Qiu Electrical Safety Test Engineer Approved by: Kenneth Fu Electrical Safety Manager Date of issue 04 November 2009 Results appearing herein relate only to the sample(s) tested. This report may not be reproduced in any form unless done so in full. Original copies of reports are printed on Austest Laboratories official Test Report letterhead, printed in reflex blue. This report is issued errors and omissions exempt and is subject to withdrawal at Austest Laboratories discretion.

Upload: others

Post on 24-Mar-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Compliance Testing Report for Australian/New Zealand ... · Doc Id: AS/NZS 60598.2.2 Page 3 of 8 Report No.: 1104EFFLED_59822 AS/NZS60598.2.2: 2001 Clause Requirement - Test Result

Doc Id: AS/NZS 60598.2.2 Page 1 of 8 Report No.: 1104EFFLED_59822

Accredited for compliance with ISO / IEC 17025. Approval Specialists Pty. Limited (ACN: 094 656 354) Trading as Austest Laboratories

Compliance Testing Report for Australian/New Zealand Standards

AS/NZS 60598.1:2003 and AS/NZS 60598.2.2:2001

Luminaires Part 2.2: Particular Requirements — Recessed Luminaires

(Limited Testing Only)

Client: Efficiency Matrix

Address: 14 Ondine Drive, Wheelers Hill, Victoria 3150

Report Number: 1104EFFLED_59822 (Replacement for report no. 1030EFFLED_59822)

Date of Testing: 29 – 30 October 2009

File Number: EFF091022

Equipment Name: LED Mitt

Equipment Model Number: Ledmitm2

Equipment Description: LED Mitt

Result: COMPLIES

Tested by: Hai Ying Qiu

Electrical Safety Test Engineer

Approved by: Kenneth Fu

Electrical Safety Manager

Date of issue 04 November 2009

Results appearing herein relate only to the sample(s) tested.

This report may not be reproduced in any form unless done so in full. Original copies of reports are printed on Austest Laboratories official Test Report letterhead, printed in reflex blue.

This report is issued errors and omissions exempt and is subject to withdrawal at Austest Laboratories discretion.

Page 2: Compliance Testing Report for Australian/New Zealand ... · Doc Id: AS/NZS 60598.2.2 Page 3 of 8 Report No.: 1104EFFLED_59822 AS/NZS60598.2.2: 2001 Clause Requirement - Test Result

Doc Id: AS/NZS 60598.2.2 Page 2 of 8 Report No.: 1104EFFLED_59822

Accredited for compliance with ISO / IEC 17025. Approval Specialists Pty. Limited (ACN: 094 656 354) Trading as Austest Laboratories

SUMMARY OF COMPLIANCE WITH AUSTRALIAN AND NEW ZEALAND STANDARDS AS/NZS 60598.1: 2003 AND AS/NZS60598.2.2: 2001

The EUT (Equipment Under Test) known as LED Mitt, model number Ledmitm2 and was supplied for AS/NZS 60598.1: 2003 and AS/NZS60598.2.2: 2001 testing by Efficiency Matrix of 14 Ondine Drive, Wheelers Hill, Victoria 3150. This report is the replacement report for the test report no. 1030EFFLED_59822 to include the Brand name and thickness of R5 thermal insulation.

The EUT was tested to clause 12.4 of AS/NZS 60598.1: 2003 and clause 2.12 of AS/NZS 60598.2.2: 2001 for surrounding parts only (timber and fibre glass batt R5)

When the EUT was tested in conjunction with timber and fibre glass batt R5 as the surrounding parts, the EUT COMPLIES with the tested clause 12.4 of AS/NZS 60598.1:2003 and clause 2.12 of AS/NZS60598.2.2:2001.

There is no restriction for installation of the LED Mitt around timber and fibre glass batt R5 as per the Australian Wiring Rules, AS/NZS 3000:2007 clause 4.5.2.3.

Method Testing was performed in accordance with the standard: 60598.1man Possible Test Case Verdicts: - test case does not apply to the test object ....................................................... N(.A) - test object does meet the requirements ............................................................ P(ass) - test object does not meet the requirements ..................................................... F(ail) - test was not performed ....................................................................................... NT(not tested) - noted ..................................................................................................................... ND

Page 3: Compliance Testing Report for Australian/New Zealand ... · Doc Id: AS/NZS 60598.2.2 Page 3 of 8 Report No.: 1104EFFLED_59822 AS/NZS60598.2.2: 2001 Clause Requirement - Test Result

Doc Id: AS/NZS 60598.2.2 Page 3 of 8 Report No.: 1104EFFLED_59822

AS/NZS60598.2.2: 2001

Clause Requirement - Test Result - Remark Verdict

Accredited for compliance with ISO / IEC 17025. Approval Specialists Pty. Limited (ACN: 094 656 354) Trading as Austest Laboratories

2.12 (12) ENDURANCE TEST AND THERMAL TEST

2.12 (12.4) Thermal test (normal operation) Refer to appended tables P

12.4 TABLE: temperature rise measurements for normal operation P

test voltage (V) .................................................... : 254.4

Temperature (0C) of part T (0C) Max. T (0C)

Surrounding parts of heat shield construct of timber A)

Timber 27 90

Inside the Mitt 36.8 Reference

Ambient 22 Reference

Surrounding parts of heat shield construct of fibre glass batt R5 B)

Fibre glass batt R5 39.8 90

Inside the Mitt 43.8 Reference

Ambient 22 Reference

A) 100mmX100mm timber side pieces were fitted as close as possible against four sides of the insulation Mitt. The thermocouples were placed on the timbers near the insulation Mitt where temperature expected to be highest. B) The 100mmX100mm timber side pieces were removed and replaced with thermal insulation in direct contact with the full circumference of the insulation Mitt. The thermocouple was placed on the thermal insulation near the insulation Mitt where temperature was expected to be highest.

*** END OF REPORT BODY ***

Appendix 1 – Critical Component List

Appendix 2 – Photographic Record of Sample

Page 4: Compliance Testing Report for Australian/New Zealand ... · Doc Id: AS/NZS 60598.2.2 Page 3 of 8 Report No.: 1104EFFLED_59822 AS/NZS60598.2.2: 2001 Clause Requirement - Test Result

Doc Id: AS/NZS 60598.2.2 Page 4 of 8 Report No.: 1104EFFLED_59822

Appendix 1 – Critical Component List

Accredited for compliance with ISO / IEC 17025. Approval Specialists Pty. Limited (ACN: 094 656 354) Trading as Austest Laboratories

Appendix 1 TABLE: Components P

Object / part No. Manufacturer/ trademark

Type / model Technical data Standard Mark(s) of conformity

Transformer TRIDONIC.ATCO VIPER Pri: 230-240V~ 50/60Hz

Sec: 11.6V

- V99

LED Lamp Green light MR-16

12V, 5W - -

Ceiling Batt R5.0 Insulco 201504 Thickness 215mm - -

1) An asterisk indicates a mark which assures the agreed level of surveillance

Page 5: Compliance Testing Report for Australian/New Zealand ... · Doc Id: AS/NZS 60598.2.2 Page 3 of 8 Report No.: 1104EFFLED_59822 AS/NZS60598.2.2: 2001 Clause Requirement - Test Result

Doc Id: AS/NZS 60598.2.2 Page 5 of 8 Report No.: 1104EFFLED_59822

Appendix 2 – Photographic Record of Sample

Accredited for compliance with ISO / IEC 17025. Approval Specialists Pty. Limited (ACN: 094 656 354) Trading as Austest Laboratories

Page 6: Compliance Testing Report for Australian/New Zealand ... · Doc Id: AS/NZS 60598.2.2 Page 3 of 8 Report No.: 1104EFFLED_59822 AS/NZS60598.2.2: 2001 Clause Requirement - Test Result

Doc Id: AS/NZS 60598.2.2 Page 6 of 8 Report No.: 1104EFFLED_59822

Appendix 2 – Photographic Record of Sample

Accredited for compliance with ISO / IEC 17025. Approval Specialists Pty. Limited (ACN: 094 656 354) Trading as Austest Laboratories

Page 7: Compliance Testing Report for Australian/New Zealand ... · Doc Id: AS/NZS 60598.2.2 Page 3 of 8 Report No.: 1104EFFLED_59822 AS/NZS60598.2.2: 2001 Clause Requirement - Test Result

Doc Id: AS/NZS 60598.2.2 Page 7 of 8 Report No.: 1104EFFLED_59822

Appendix 2 – Photographic Record of Sample

Accredited for compliance with ISO / IEC 17025. Approval Specialists Pty. Limited (ACN: 094 656 354) Trading as Austest Laboratories

Page 8: Compliance Testing Report for Australian/New Zealand ... · Doc Id: AS/NZS 60598.2.2 Page 3 of 8 Report No.: 1104EFFLED_59822 AS/NZS60598.2.2: 2001 Clause Requirement - Test Result

Doc Id: AS/NZS 60598.2.2 Page 8 of 8 Report No.: 1104EFFLED_59822

Appendix 2 – Photographic Record of Sample

Accredited for compliance with ISO / IEC 17025. Approval Specialists Pty. Limited (ACN: 094 656 354) Trading as Austest Laboratories