ROBINSON BUILDING COMPLEX Project No.: 4917/A4L-400/962470 SCHOOL OF GLOBAL POLICY & STRATEGY (GPS) RENOVATION UNIVERSITY OF CALIFORNIA, SAN DIEGO
UCSD - FD&C Page 1 of 1
ADDENDUM NO. ONE TO THE CONSTRUCTION DOCUMENTS May 5, 2016 General:
The following changes, additions or deletions shall be made to the following documents; all other conditions shall remain the same. I. DRAWINGS Item#
1. Delete the following listed Sheets in their entirety and substitute with the attached revised sheets dated 05/05/16. Revised Sheets: A612, A613, A614, A615, A801, A903, S102, S103, and S104
LEVEL 2435' - 6"
09.26.01
09.26
10.61
09.63
LEVEL 2435' - 6"
09.7709.55
09.51
09.26
3DA801
3CA801
3CA801
3DA801
10.41
A61210
SIM
09.63
LEVEL 2435' - 6"
09.5109.77 09.5509.26 16A903
3CA801
3BA801
3DA801
10.52.023A
A801 09.63
3BA801
SIM
3DA801
O.H.
LEVEL 2435' - 6"
OPEN
09.5509.26.02 09.26.0116.5111.13.01
09.26
09.51
A90316 A903
14
A90316
09.632D
A801
2DA801
2BA801
2AA801
10A612
A90318
2FA801
2FA801 LEVEL 2
435' - 6"
A8012C
A8012A
09.51
09.55
16.51
2BA801
16.51
W2.2
EX
LEVEL 2435' - 6"
10.61
10.62
09.26.01
LEVEL 2435' - 6"
10.61
09.26.01
LEVEL 2435' - 6"
10.61
09.26.01
09.26
09.63
LEVEL 2435' - 6"
D C.7
09.26.01
10.11
09.63
09.26
LEVEL 2435' - 6"
C.7
10.61
09.26.01
INDICATES (E) OBJECTS TO REMAIN
ACOUSTIC FABRIC PANEL
WOOD PANEL
LEVEL 1424' - 0"
10.61
09.52
10.61
10.62
10.61
09.62
W4.3W4.3
LEVEL 1424' - 0"
12.51
09.26
10.61
09.63
LEVEL 1424' - 0"
09.26
W4.3
10' - 0" TYP
09.63
EQ EQ
LEVEL 1424' - 0"
09.26
12.35
15.41.01
12.35
LEVEL 1424' - 0"
2
10.61
10.62
09.26
LEVEL 1424' - 0"
EDC.7C
09.51
10.61
09.26
10.41
10.62
LEVEL 1424' - 0"
09.26
11.13.02
12.51
W4.3
10.61
09.63
09.51
A90316
SIM16.51
LEVEL 1424' - 0"
09.55
09.51
16.5116.51
2BA801
2AA801
2CA801
A90318
A90316
09.63
A61221
SIM
SIM
16.51
09.55
09.512BA801
2AA801
2CA801
A90318
A90316
09.63A612
21
7' - 4 3/4"
SIMSIM
4S103
TYP.
LEVEL 1424' - 0"
H G
01.92
12.49.1
09.52
09.51
09.26
11.13.02
12.51
09.63
A90316
SIM
09.55
21A612
7' - 4 3/4"
LEVEL 1424' - 0"
WOOD VENEER WALL PANELS
MOUNTING HARDWARE
SEE 6/S102 FORFRAMING, TYP.
RESILIENT WALL BASE
PTD. SHEATHING
LEVEL 1424' - 0"
H
12.49.1
09.5209.52
10.61
09.26
09.63
09.62
10.61
01.92 A90316
SIM
NO. C 9136
REN 9-30-15
LIC
ENSED ARCHITECT
STATE OF CA LIFORNIA
JOS
EPH
ON -WOO
WO
GN
Date
Drawn By
Checked By
Project No.
All id
eas,
desig
ns, a
rrang
emen
ts an
d plan
sind
icated
or re
pres
ented
by th
is dr
awing
are
owne
d by,
and t
he pr
oper
ty of
Jose
ph W
ong
Desig
n Ass
ociat
es, a
nd w
ere c
reate
d,ev
olved
and d
evelo
ped f
or us
e on,
and i
nco
nnec
tion w
ith, th
e spe
cified
proje
ct. N
one
of su
ch id
eas,
desig
ns, a
rrang
emen
ts or
plans
shall
be us
ed w
ithou
t the w
ritten
perm
ission
of Jo
seph
Won
g Des
ignAs
socia
tes. W
ritten
dime
nsion
s on t
hese
draw
ings s
hall h
ave p
rece
denc
e ove
r sca
leddim
ensio
ns. C
ontra
ctors
shall
verify
and b
ere
spon
sible
for al
l dim
ensio
ns an
dco
nditio
ns on
the j
ob, a
nd th
is off
ice m
ust b
eno
tified
of al
l var
iation
s fro
m the
dime
nsion
san
d con
dition
s sho
wn by
thes
e dra
wing
s.
JWD
AA
R C
H I T
E C
T U
R E
/ P
L A
N N
I N
G / I N
T E
R I O
R D
E S
I G
N
Joseph W
ong D
esig
n A
ssocia
tes
235
9 F
ou
rth
Aven
ue
San D
iego,
Ca
lifo
rnia
9210
1-1
606
Pho
ne (
61
9)
233
-67
77
Fax (
61
9)
237
-05
41
REVISIONS:
Scale
Proje
ct Na
me
4/28
/201
6 15
:11:
54
As indicated
A612
INTE
RIOR
EL E
V ATI
O NS
UNIV
ERSI
TY O
F CA
LIFO
RNIA
SAN
DIE
GO
ROBI
NSON
BUI
LDIN
G CO
MPL
EX
JWDAJWDA
04/18/20163239 | UCSD 4917
9500
GIL
MAN
DRI
VE, L
A JO
LLA,
CA
9209
3
SCHO
OL O
F GP
S - R
ENOV
ATIO
N
1/4" = 1'-0"5 3213 - E
SHEET KEYNOTES01.92 (E) STOREFRONT SYSTEM TO REMAIN -
PROTECT AS REQ'D09.26 GYP. BOARD, TYP. - PAINTED09.26.01 GYP. BD. CEILING, TYP. - PAINTED09.26.02 (E) GYP. BD. CEILING - PATCH AS REQ'D,
PAINTED09.51 WOOD VENEER CEILING PANELS09.52 ACOUSTICAL CEILING PANEL09.55 WOOD VENEER WALL PANELS09.62 SOLID VINYL TILE FLOORING - SVT-209.63 RESILIENT WALL BASE09.77 GLASS WALL CLADDING SYSTEM10.11 WHITE BOARD - BY OTHERS10.41 INTERIOR ROOM SIGNAGE10.52.02 FIRE EXTINGUISHER CABINET - RELOCATED10.61 DEMOUNTABLE INTERIOR GLASS PARTITION
SYSTEM - BY OTHERS10.62 DEMOUNTABLE INTERIOR GLASS PARTITION
SYSTEM (DOOR) - BY OTHERS11.13.01 MEDIA MONITOR11.13.02 PROJECTOR SCREEN12.35 CASEWORK12.49.1 MANUALLY OPERATED SINGLE ROLLER SHADE12.51 FURNITURE - BY OTHERS15.41.01 PLUMBING FIXTURES16.51 LIGHT FIXTURE PER ELECTRICAL
1/4" = 1'-0"7 3200C - A 1/4" = 1'-0"8 3200C - B
1/4" = 1'-0"9 3200C - C 1/2" = 1'-0"10 CEILING/ WALL SECTION
1/4" = 1'-0"1 3213 - A 1/4" = 1'-0"2 3213 - B
1/4" = 1'-0"3 3213 - C 1/4" = 1'-0"4 3213 - D
1/4" = 1'-0"6 3213 - F
SHEET LEGEND
1/4" = 1'-0"11 OFFICE TYP. - ELEVATION 1 1/4" = 1'-0"12 OFFICE TYP. - ELEVATION 2 1/4" = 1'-0"13 OFFICE TYP. - ELEVATION 3
1/4" = 1'-0"15 3133 - ELEVATION 1
1/4" = 1'-0"16 3107 - ELEVATION 2
1/4" = 1'-0"22 3106 - ELEVATION 1 1/4" = 1'-0"23 3106 - ELEVATION 2
1/4" = 1'-0"19 3106B - SECTION 1 1/4" = 1'-0"20 3106B - SECTION 2
1/4" = 1'-0"17 3107 - ELEVATION 1 1/4" = 1'-0"18 3106B - ENLARGED PLAN
3" = 1'-0"21 3106B - DETAIL 1
NO. DESCRIPTION DATE1 ADDENDUM 1 4/26/16
1/4" = 1'-0"14 2 - d
1
5/5/16
INDICATES (E) OBJECTS TO REMAIN
ACOUSTIC FABRIC PANEL
WOOD PANEL
LEVEL 1B432' - 4"
10.11
09.26
09.63
09.26.02
LEVEL 1A435' - 0"
16A613
LEVEL 1B432' - 4"
12.49.209.81 09.26.0212.49.212.49.212.49.2 01.92
LEVEL 1B432' - 4"
10.11
09.63
09.26
LEVEL 1A435' - 0"
12.49.209.8110.41 09.26 09.26.02
09.63
LEVEL 1B432' - 4"
10.11
11.13.02
09.26.02
09.26
09.63
LEVEL 1A435' - 0"
09.81
09.26.02
09.63
LEVEL 1A435' - 0"
09.81
09.26.02
09.63
LEVEL 1A435' - 0"
09.81
09.26.02
09.63
LEVEL 1A435' - 0"
09.81 10.4109.2609.26.02
09.63
MOTOR OPERATED DOUBLEROLLER SHADES
(E) WALL/ SOFFIT TOREMAINMTL. FRAME PER DETAIL 3/S102
(E) SPANDREL GLASS
48" M
AX. A
.F.F
.TO
CON
TROL
S
SHADE BRACKET
REMOVABLE CLOSURE
(E) STOREFRONT SYSTEM TOREMAIN - PROTECT AS REQ'D
DRIVE CHAIN
SHADE CLOTH
1
(E) WALL/ SOFFIT TOREMAIN
FASCIA, FRONT & BACK, TYP.
(E) ALUMINUMSTOREFRONT SYSTEM TOREMAIN
CEILING PER RCP
MANUALLY OPERATED SINGLEROLLER SHADE
(E) GLAZING
CLOSURE
EXPOSED HEM BAR
WALL MOUNT ANGLE
SHADE CLOTH
DRIVE CHAIN
48" M
AX. A
.F.F
.TO
CON
TROL
S
SIM: SHADE SYSTEM RECESSED INCEILING, PER RCP
LEVEL 1A435' - 0"
09.77
11.13.01
16.51
09.55
09.51
09.26
05.71
A90314
A90318
3BA801
3CA801
2BA801
2DA801
2DA801
10A612
13A613
12A613
(E) WALL TO REMAIN
MTL. FRAME& MOUNTINGHARDWARE
PTD. SHEATHING
WOOD VENEER WALL PANELS
INTERIOR STAND-OFF SIGNAGE
A8012F
SIM
11A613
WOOD VENEER WALL PANELS
(E) WALL TO REMAIN
MTL. FRAME& MOUNTINGHARDWARE
INTERIOR STAND-OFF SIGNAGE
MTL. ANGLE TRIM
WOOD VENEER WALL PANELS
WOOD VENEER WALL PANELS
GLASS WALL CLADDING SYSTEM
MOUNTING HARDWARE
(E) WALL TO REMAIN
1/4"
A8012F
0' - 2"
MOUNTING HARDWARE
(E) WALL TO REMAIN
3/4" SHEATHING
MTL. TRIM
MTL. TRIM
< 2X2 X 18 GA BENT PLATE W/ #8SCREW @ 16" AT SPLICE, TYP.
GLASS WALL CLADDING SYSTEM
< 2X2 X 18 GA BENT PLATE W/ #10X1"SCREW @ 16" TO (E) STUD
LEVEL 2435' - 6"
RESILIENT WALL BASE
SOLID VINYL TILE FLOORING -SVT-2
SOLID VINYL TILE FLOORING -SVT-2
RESILIENT TIERED PLATFORMTRANSITION
TIER STRUCTURE PER7/S104, TYP.
RESILIENT WALL BASE
LAP OVER BASE, TYP.
5" T
YP
H
(E) STOREFRONT SYSTEM TOREMAIN - PROTECT AS REQ'D
W4.3
FRAMING PERSTRUCTURAL
SEALANT, TYP.
PRE-FINISHED SHEETMETAL, TO MATCH (E)MULLION
NO. C 9136
REN 9-30-15
LIC
ENSED ARCHITECT
STATE OF CA LIFORNIA
JOS
EPH
ON -WOO
WO
GN
Date
Drawn By
Checked By
Project No.
All id
eas,
desig
ns, a
rrang
emen
ts an
d plan
sind
icated
or re
pres
ented
by th
is dr
awing
are
owne
d by,
and t
he pr
oper
ty of
Jose
ph W
ong
Desig
n Ass
ociat
es, a
nd w
ere c
reate
d,ev
olved
and d
evelo
ped f
or us
e on,
and i
nco
nnec
tion w
ith, th
e spe
cified
proje
ct. N
one
of su
ch id
eas,
desig
ns, a
rrang
emen
ts or
plans
shall
be us
ed w
ithou
t the w
ritten
perm
ission
of Jo
seph
Won
g Des
ignAs
socia
tes. W
ritten
dime
nsion
s on t
hese
draw
ings s
hall h
ave p
rece
denc
e ove
r sca
leddim
ensio
ns. C
ontra
ctors
shall
verify
and b
ere
spon
sible
for al
l dim
ensio
ns an
dco
nditio
ns on
the j
ob, a
nd th
is off
ice m
ust b
eno
tified
of al
l var
iation
s fro
m the
dime
nsion
san
d con
dition
s sho
wn by
thes
e dra
wing
s.
JWD
AA
R C
H I T
E C
T U
R E
/ P
L A
N N
I N
G / I N
T E
R I O
R D
E S
I G
N
Joseph W
ong D
esig
n A
ssocia
tes
235
9 F
ou
rth
Aven
ue
San D
iego,
Ca
lifo
rnia
9210
1-1
606
Pho
ne (
61
9)
233
-67
77
Fax (
61
9)
237
-05
41
REVISIONS:
Scale
Proje
ct Na
me
4/28
/201
6 15
:12:
00
As indicated
A613
INTE
RIOR
EL E
V ATI
O NS
UNIV
ERSI
TY O
F CA
LIFO
RNIA
SAN
DIE
GO
ROBI
NSON
BUI
LDIN
G CO
MPL
EX
CheckerAuthor
04/18/20163239 | UCSD 4917
9500
GIL
MAN
DRI
VE, L
A JO
LLA,
CA
9209
3
SCHO
OL O
F GP
S - R
ENOV
ATIO
N
SHEET KEYNOTES01.92 (E) STOREFRONT SYSTEM TO REMAIN -
PROTECT AS REQ'D05.71 MTL. ANGLE TRIM09.26 GYP. BOARD, TYP. - PAINTED09.26.02 (E) GYP. BD. CEILING - PATCH AS REQ'D,
PAINTED09.51 WOOD VENEER CEILING PANELS09.55 WOOD VENEER WALL PANELS09.62 SOLID VINYL TILE FLOORING - SVT-209.63 RESILIENT WALL BASE09.66 RESILIENT TIERED PLATFORM TRANSITION09.77 GLASS WALL CLADDING SYSTEM09.81 ACOUSTIC WALL PANELS10.11 WHITE BOARD - BY OTHERS10.41 INTERIOR ROOM SIGNAGE10.42 INTERIOR STAND-OFF SIGNAGE11.13.01 MEDIA MONITOR11.13.02 PROJECTOR SCREEN12.49.1 MANUALLY OPERATED SINGLE ROLLER SHADE12.49.2 MOTOR OPERATED DOUBLE ROLLER SHADES16.51 LIGHT FIXTURE PER ELECTRICAL
SHEET LEGEND
1/4" = 1'-0"3 2101 - C 1/4" = 1'-0"4 2101 - D
1/4" = 1'-0"1 2101 - A
1/4" = 1'-0"9 2101 - J
1/4" = 1'-0"2 2101 - B
1/4" = 1'-0"8 2101 - H 1/4" = 1'-0"7 2101 - G
1/4" = 1'-0"6 2101 - F 1/4" = 1'-0"5 2101 - E
3" = 1'-0"16 DOUBLE ROLLER SHADE DETAIL 3" = 1'-0"15 SINGLE ROLLER SHADE DETAIL
1/4" = 1'-0"10 2116 - A 3" = 1'-0"11 STAND-OFF SIGNAGE
3" = 1'-0"12 STAND-OFF SIGNAGE
3" = 1'-0"13 WALL CORNER DETAIL
3" = 1'-0"14 WALL/ OPENING DETAIL
6" = 1'-0"17 TIER RISER TRANSITION, TYP.
NO. DESCRIPTION DATE1 ADDENDUM 1 4/26/16
3" = 1'-0"18 BLDG 3 - L1 - PLN (N) - WALL & SFNT
1
1
5/5/16
INDICATES (E) OBJECTS TO REMAIN
WALL TILE - PWT
WOOD PANEL
HDR
16.51
09.26
09.31
10.4109.26.01 09.26.0209.26
15.41.01
WR
MRR
15.41.01
MRR
09.26.01
09.31
09.26
2' - 0"
4' - 0
"
15.41.0115.41.01
MRR
09.26
09.31
10.15
09.26.01
4' - 0
"
2' - 0"
5CA801
5BA801
TYP
TYP
15.41.01
10.15
16.51
TSCDGBR
09.26.02
TSCD
10.1509.26
09.31
TPD
TSCD
3' - 6
" TY
P
5A801
09.26.02
09.26.01
09.26
09.31
09.32
TYP
16.51
HDRSNTD
MRR
15.41.01
09.26
09.31
09.26.01
09.26.01
WR
5AA801
SNTDHDRMRR
15.41.01
09.26.01
09.26
09.26.02
WR
09.31
2' - 0"
4' - 0
"
5AA801
5CA801
MRR
SND TPD
09.26.01
16.51
15.41.01
4' - 0
"
2' - 0"
09.26
09.31
09.32
GBR
10.15
15.41.01
09.31
09.26
09.26.01
09.26.02
TSCD
TPDSND
09.32
TSCD
09.26.01
3' - 6
" TY
P
5A801
09.26
09.31
09.26.02
TYP
09.26
09.31
15.41.01
GBR
TPD
MRR15.41.01
TSCD
SND
10.15
4' - 0
"
5' - 0"
5AA801 5A
A801
5BA801
5CA801
TYP TYP
09.26.01
16.51
09.26
09.31
5A801
TYP
09.31 09.26
HDR SNTDWR
TYP5C
A801
5BA801 TYP
09.26
16.5116.51
09.26.01
MRRSNTD
15.41.01
09.31
5AA801
MRR
09.31
09.26
5' - 0"
4' - 0
"
15.41.01
5CA801
5BA801
TYP
TYP09.26
09.31
5A801
TYP
5AA801
09.26
09.31
09.26
15.41.01
GBR
09.26.01
10.15
TSCD
TPD
5AA801
5AA801
09.26
16.51
09.26.01
16.51
15.41.01
09.31
GBRMRRTSCD
TPD
5AA801
09.26
09.31
HDR
WR
3' - 6
" TY
P
NO. C 9136
REN 9-30-15
LIC
ENSED ARCHITECT
STATE OF CA LIFORNIA
JOS
EPH
ON -WOO
WO
GN
Date
Drawn By
Checked By
Project No.
All id
eas,
desig
ns, a
rrang
emen
ts an
d plan
sind
icated
or re
pres
ented
by th
is dr
awing
are
owne
d by,
and t
he pr
oper
ty of
Jose
ph W
ong
Desig
n Ass
ociat
es, a
nd w
ere c
reate
d,ev
olved
and d
evelo
ped f
or us
e on,
and i
nco
nnec
tion w
ith, th
e spe
cified
proje
ct. N
one
of su
ch id
eas,
desig
ns, a
rrang
emen
ts or
plans
shall
be us
ed w
ithou
t the w
ritten
perm
ission
of Jo
seph
Won
g Des
ignAs
socia
tes. W
ritten
dime
nsion
s on t
hese
draw
ings s
hall h
ave p
rece
denc
e ove
r sca
leddim
ensio
ns. C
ontra
ctors
shall
verify
and b
ere
spon
sible
for al
l dim
ensio
ns an
dco
nditio
ns on
the j
ob, a
nd th
is off
ice m
ust b
eno
tified
of al
l var
iation
s fro
m the
dime
nsion
san
d con
dition
s sho
wn by
thes
e dra
wing
s.
JWD
AA
R C
H I T
E C
T U
R E
/ P
L A
N N
I N
G / I N
T E
R I O
R D
E S
I G
N
Joseph W
ong D
esig
n A
ssocia
tes
235
9 F
ou
rth
Aven
ue
San D
iego,
Ca
lifo
rnia
9210
1-1
606
Pho
ne (
61
9)
233
-67
77
Fax (
61
9)
237
-05
41
REVISIONS:
Scale
Proje
ct Na
me
4/28
/201
6 15
:12:
03
1/4" = 1'-0"
A614
INTE
RIOR
EL E
V ATI
O NS
UNIV
ERSI
TY O
F CA
LIFO
RNIA
SAN
DIE
GO
ROBI
NSON
BUI
LDIN
G CO
MPL
EX
JWDAJWDA
04/18/20163239 | UCSD 4917
9500
GIL
MAN
DRI
VE, L
A JO
LLA,
CA
9209
3
SCHO
OL O
F GP
S - R
ENOV
ATIO
N
SHEET KEYNOTES09.26 GYP. BOARD, TYP. - PAINTED09.26.01 GYP. BD. CEILING, TYP. - PAINTED09.26.02 (E) GYP. BD. CEILING - PATCH AS REQ'D,
PAINTED09.31 PORCELAIN WALL TILE - WT09.32 PORCELAIN FLOOR TILE - FT10.15 COMPARTMENT PARTITIONS, SCREENS &
ACCESSORIES10.41 INTERIOR ROOM SIGNAGE15.41.01 PLUMBING FIXTURES16.51 LIGHT FIXTURE PER ELECTRICAL
SHEET LEGEND
1/4" = 1'-0"1 2109 - ELEVATION 1 1/4" = 1'-0"2 2109 - ELEVATION 2
1/4" = 1'-0"3 2109 - ELEVATION 3 1/4" = 1'-0"4 2109 - ELEVATION 4
1/4" = 1'-0"5 2109 - ELEVATION 5
1/4" = 1'-0"6 2110 - ELEVATION 1 1/4" = 1'-0"7 2110 - ELEVATION 2
1/4" = 1'-0"8 2110 - ELEVATION 3 1/4" = 1'-0"9 2110 - ELEVATION 4
1/4" = 1'-0"10 2110 - ELEVATION 5
1/4" = 1'-0"11 3118 - ELEVATION 1 1/4" = 1'-0"12 3118 - ELEVATION 2
1/4" = 1'-0"13 3118 - ELEVATION 3 1/4" = 1'-0"14 3118 - ELEVATION 4
1/4" = 1'-0"15 3119 - ELEVATION 1 1/4" = 1'-0"16 3119 - ELEVATION 2
1/4" = 1'-0"17 3119 - ELEVATION 3 1/4" = 1'-0"18 3119 - ELEVATION 4
1/4" = 1'-0"19 3119 - ELEVATION 5 1/4" = 1'-0"20 3119 - ELEVATION 6
NO. DESCRIPTION DATE1 ADDENDUM 1 4/26/16
1
1
1
1
15/5/16
INDICATES (E) OBJECTS TO REMAIN
WALL TILE - PWT
WOOD PANEL
15.41.01
09.26.01
TSCD
TPD
GBR
09.26
09.3109.26
09.26.01
15.41.01
TSCD
TPD
09.31
3' - 6
" TY
P
MRR
4' - 0
"
2' - 0"
5CA801
5BA801
15.41.01
HDR
MRR
WR
15.41.01
09.26
09.31
5A801
TYP
09.31
09.26
09.3109.26 08.11
WR 5AA801
09.26 15.41.0109.31
TSCD GBR
09.26.01 10.15
SND TPD
TSCD
09.26 09.3109.26.01
09.26
09.26.01
09.31
15.41.01
5AA801
09.3109.26 10.80 MRR SNTD15.41.01 09.26.01HDR
4' - 0
"
5' - 0"WR
3' - 6
" TY
P
5A801
TYP
5AA801
5AA801
5BA801
5CA801
TYP
TYP
09.26.01 10.15?09.31
5AA801
15.41.01
10.80
TPD
TSCD
GBR
15.41.01
HDR
4' - 0
"
5' - 0"
MRR
5AA801
5BA801
5CA801
TYP TYP
09.26
09.26.01
09.32
15.41.01
GBR
TPD
09.31
09.26.01 09.26 09.31
TSCD5
A801TYP
TSCD
09.31
09.26
09.26.01
15.41.013' - 6
" TY
P
TPD
NO. C 9136
REN 9-30-15
LIC
ENSED ARCHITECT
STATE OF CA LIFORNIA
JOS
EPH
ON -WOO
WO
GN
Date
Drawn By
Checked By
Project No.
All id
eas,
desig
ns, a
rrang
emen
ts an
d plan
sind
icated
or re
pres
ented
by th
is dr
awing
are
owne
d by,
and t
he pr
oper
ty of
Jose
ph W
ong
Desig
n Ass
ociat
es, a
nd w
ere c
reate
d,ev
olved
and d
evelo
ped f
or us
e on,
and i
nco
nnec
tion w
ith, th
e spe
cified
proje
ct. N
one
of su
ch id
eas,
desig
ns, a
rrang
emen
ts or
plans
shall
be us
ed w
ithou
t the w
ritten
perm
ission
of Jo
seph
Won
g Des
ignAs
socia
tes. W
ritten
dime
nsion
s on t
hese
draw
ings s
hall h
ave p
rece
denc
e ove
r sca
leddim
ensio
ns. C
ontra
ctors
shall
verify
and b
ere
spon
sible
for al
l dim
ensio
ns an
dco
nditio
ns on
the j
ob, a
nd th
is off
ice m
ust b
eno
tified
of al
l var
iation
s fro
m the
dime
nsion
san
d con
dition
s sho
wn by
thes
e dra
wing
s.
JWD
AA
R C
H I T
E C
T U
R E
/ P
L A
N N
I N
G / I N
T E
R I O
R D
E S
I G
N
Joseph W
ong D
esig
n A
ssocia
tes
235
9 F
ou
rth
Aven
ue
San D
iego,
Ca
lifo
rnia
9210
1-1
606
Pho
ne (
61
9)
233
-67
77
Fax (
61
9)
237
-05
41
REVISIONS:
Scale
Proje
ct Na
me
4/28
/201
6 15
:12:
08
1/4" = 1'-0"
A615
INTE
RIOR
EL E
V ATI
O NS
UNIV
ERSI
TY O
F CA
LIFO
RNIA
SAN
DIE
GO
ROBI
NSON
BUI
LDIN
G CO
MPL
EX
JWDAJWDA
04/18/20163239 | UCSD 4917
9500
GIL
MAN
DRI
VE, L
A JO
LLA,
CA
9209
3
SCHO
OL O
F GP
S - R
ENOV
ATIO
N
SHEET KEYNOTES08.11 DOOR PER SCHEDULE09.26 GYP. BOARD, TYP. - PAINTED09.26.01 GYP. BD. CEILING, TYP. - PAINTED09.31 PORCELAIN WALL TILE - WT09.32 PORCELAIN FLOOR TILE - FT10.15 COMPARTMENT PARTITIONS, SCREENS &
ACCESSORIES10.80 TOILET ROOM ACCESSORIES15.41.01 PLUMBING FIXTURES16.51 LIGHT FIXTURE PER ELECTRICAL
SHEET LEGEND
1/4" = 1'-0"1 3212 - ELEVATION 1
1/4" = 1'-0"2 3212 - ELEVATION 2 1/4" = 1'-0"3 3212 - ELEVATION 3
1/4" = 1'-0"4 3212 - ELEVATION 4
1/4" = 1'-0"5 3214 - ELEVATION 1 1/4" = 1'-0"6 3214 - ELEVATION 2
1/4" = 1'-0"7 3214 - ELEVATION 3 1/4" = 1'-0"8 3214 - ELEVATION 4
1/4" = 1'-0"9 3214 - ELEVATION 5
1/4" = 1'-0"10 3215 - ELEVATION 1 1/4" = 1'-0"11 3215 - ELEVATION 2
1/4" = 1'-0"12 3215 - ELEVATION 3 1/4" = 1'-0"13 3215 - ELEVATION 4
1/4" = 1'-0"14 3215 - ELEVATION 5
NO. DESCRIPTION DATE1 ADDENDUM 1 4/26/16
1
1
1
5/5/16
4" METAL STUDS FRAMING@ 16" O.C., SEESTRUCTURAL FOR GA.
5/8" TYPE "X" GYPSUMBOARD
INTERIOR
HEAD
PLAN
SILL
CONTINOUS SLOTTEDTRACK
1/2" DEPTH OF FIRE RATEDSEALANT (UL HW-D-0103)
FIRE RATED SEALANT, FULLTHICKNESS OF GYP. BOARDBOTH SIDES, MAX. 3/4" HIGHJOINT (UL BW-S-0001)
W1
INTERIOR
4" SOUND BATTINSULATION, FULLHEIGHT
FIRE DESIGN: U.L. - U419 1 HR FIRE RATING
MINERAL WOOLPACKING
LEVEL 2435' - 6"
WOOD VENEER WALL PANELS
MTL. FRAME
(E) WALL/ FLOOR TO REMAIN
MOUNTING HARDWARE
W2
W2.1WVWP /3/4" SHEATHING
7/8" 3/8"W2.2
WVWP /3/4" SHEATHING /
4" MTL STUD
W2.3WVWP /
3/4" SHEATHING /4" MTL STUD /
3/4" SHEATHING /WVWP
RESILIENT WALL BASE
WOOD VENEER WALL PANELS
WOOD VENEER CEILING PANELS
(E) WALL TO REMAIN
MOUNTING HARDWARE
MTL. FRAME, TYP.1/4"
1/4"
MTL. FRAME, TYP.
WOOD VENEER WALL PANELS
(E) WALL TO REMAIN
LIGHT FIXTURE PER ELECTRICAL
FIRE RATED WALL ASSEMBLYPER WALL TYPE
EZ-PATH RATED PATHWAY, TYP.(UL 1479)
MEDIA MONITOR
WOOD VENEER WALL PANELS
(E) WALL TO REMAIN
MTL. FRAME& MNTGHARDWARE
PTD. BACKING ASREQ'D
MTL. ANGLE TRIM
FIRE RATED WALL ASSEMBLYPER WALL TYPE
(UL W-L-1054)
MAX. 6" DIA. STEEL OR IRONPIPE, COPPER PIPE OR TUBE,STEEL CONDUIT OR MAX. 4" DIA.EMT.
INTUMESCENT FIRESTOPSEALANT MIN. 5/8" THICK, TYP.
EXISTING 1HR RATEDFLOOR ASSEMBLY
(UL C-AJ-1150)
MAX. 6" DIA. STEEL OR IRONPIPE, COPPER PIPE ORTUBE, STEEL CONDUIT ORMAX. 4" DIA. EMT.
INTUMESCENT FIRESTOPSEALANT MIN
MIN. 4" THICKNESS OF 4.0PCF MINERAL WOOLPACKING
3/8"
GLASS WALL CLADDING SYSTEM
MOUNTING HARDWARE
(E) WALL TO REMAIN
3/4' SHEATHING
3/8"
GLASS WALL CLADDING SYSTEM
MOUNTING HARDWARE
(E) WALL TO REMAIN
3/4" SHEATHING
MOUNTING HARDWARE
(E) WALL TO REMAIN
3/4" SHEATHING
GLASS WALL CLADDING SYSTEM
WOOD VENEER WALL PANELS
MTL. ANGLE TRIM
THINSET PORCELAIN TILEWALL FINISH
5/8" PTD. GYPSUM BOARDSHEATHING
FRAMING - WALL PERPLAN
METAL EDGE TRIM
TILE BACKER SHEATHINGAT ALL TILE LOCATIONS
W5
W5.3
W5.2
GYP BRD. (ABOVE) /TILE (BELOW) /
5/8" TILE BACKER BRD. /6" MTL STUD /
GYP BRD.
(N) GYP BRD. (ABOVE) /(N) TILE (BELOW) /
(N) 5/8” TILE BACKER BRD. /(E) FRAMING AND/OR FINISH
W5.0
GYP BRD. (ABOVE) /TILE (BELOW) /
5/8" TILE BACKER BRD. /3 5/8" MTL STUD
W5.1
GYP BRD. (ABOVE) & TILE (BELOW) /5/8" TILE BACKER /3 5/8" MTL STUD /
5/8" TILE BACKER /GYP BRD. (ABOVE) & TILE (BELOW)
SIM: NO TILE OPPOSITE SIDE
THINSET PORCELAIN TILEFLOOR FINISH
(E) FLOOR DECK
LEVEL 2435' - 6"
3/8"
MOUNTING HARDWARE
(E) WALL TO REMAIN
3/4' SHEATHING
GLASS WALL CLADDING SYSTEM
W3
RESILIENT WALL BASE
METAL STUDS FRAMING @16" O.C., SEE STRUCTURALFOR GA.
5/8" GYPSUMBOARD
INTERIOR
HEAD
PLAN
SILL
CONTINOUS SLOTTEDTRACK
SEALANT, BOARDBOTH SIDES, MAX.3/4" HIGH JOINT
W4
INTERIOR
SOUND BATT INSULATION,FULL HEIGHT
W4.3
GYP BOARD /2 1/2" MTL STUD
W4.2GYP BOARD /3 5/8" MTL STUD
W4.1
GYP BOARD /3 5/8" MTL STUD / GYP.
BOARD
MTL. ANGLE
1/4"
WALL PER PLAN
MOUNTINGHARDWARE
ALIGN
WOOD VENEER WALL PANELS
SIM: ADJACENTWALL/ FINISH
1/4"
1/4"
(E) WALL TO REMAIN
MTL. FRAME& MNTGHARDWARE
WOOD VENEER WALL PANELS
MTL. ANGLE TRIM
WOOD VENEER WALL PANELS
THINSET PORCELAIN TILEWALL FINISH
FRAMING - WALL PERPLAN
TILE BACKER SHEATHINGAT ALL TILE LOCATIONS
LAP OVER TILE
ACCESSORIES, TYP.
PTD. GYP. BOARD
PTD. WOOD SHIM, MATCHTHICKNESS OF TILE
FRAMING/ BACKING
MTL. TRIM AND TILE(BELOW)
ACCESSORIES, TYP.
PTD. GYP. BOARD
PTD. WOOD SHIM, MATCHTHICKNESS OF TILE
MTL. TRIM AND TILE
NO. C 9136
REN 9-30-15
LIC
ENSED ARCHITECT
STATE OF CA LIFORNIA
JOS
EPH
ON -WOO
WO
GN
Date
Drawn By
Checked By
Project No.
All id
eas,
desig
ns, a
rrang
emen
ts an
d plan
sind
icated
or re
pres
ented
by th
is dr
awing
are
owne
d by,
and t
he pr
oper
ty of
Jose
ph W
ong
Desig
n Ass
ociat
es, a
nd w
ere c
reate
d,ev
olved
and d
evelo
ped f
or us
e on,
and i
nco
nnec
tion w
ith, th
e spe
cified
proje
ct. N
one
of su
ch id
eas,
desig
ns, a
rrang
emen
ts or
plans
shall
be us
ed w
ithou
t the w
ritten
perm
ission
of Jo
seph
Won
g Des
ignAs
socia
tes. W
ritten
dime
nsion
s on t
hese
draw
ings s
hall h
ave p
rece
denc
e ove
r sca
leddim
ensio
ns. C
ontra
ctors
shall
verify
and b
ere
spon
sible
for al
l dim
ensio
ns an
dco
nditio
ns on
the j
ob, a
nd th
is off
ice m
ust b
eno
tified
of al
l var
iation
s fro
m the
dime
nsion
san
d con
dition
s sho
wn by
thes
e dra
wing
s.
JWD
AA
R C
H I T
E C
T U
R E
/ P
L A
N N
I N
G / I N
T E
R I O
R D
E S
I G
N
Joseph W
ong D
esig
n A
ssocia
tes
235
9 F
ou
rth
Aven
ue
San D
iego,
Ca
lifo
rnia
9210
1-1
606
Pho
ne (
61
9)
233
-67
77
Fax (
61
9)
237
-05
41
REVISIONS:
Scale
Proje
ct Na
me
4/28
/201
6 15
:12:
12
3" = 1'-0"
A801
WAL
L TY
P ES ,
FIR
E RA
TED
A SS E
MB L
I ES
UNIV
ERSI
TY O
F CA
LIFO
RNIA
SAN
DIE
GO
ROBI
NSON
BUI
LDIN
G CO
MPL
EX
JWDAJWDA
04/18/20163239 | UCSD 4917
9500
GIL
MAN
DRI
VE, L
A JO
LLA,
CA
9209
3
SCHO
OL O
F GP
S - R
ENOV
ATIO
N
3" = 1'-0"1 - 1-HR FIRE RATED PARTITION
3" = 1'-0"2 - WOOD VENEER WALL PANEL
2C - HEAD
2B - PLAN
3" = 1'-0"11 - CABLE TRAY PENETRATION AT 1 HR RATED WALL
2D - TRIM HEAD/ JAMB DTL.
3" = 1'-0"AT 1 HR RATED WALL
3" = 1'-0"AT 1 HR RATED FLOOR
A. PIPES, CONDUITS, ETC. PASSING THROUGH RATED WALLS, FLOORS, ROOFS, ETC.SHALL BE FIRE-STOPPED WITH A UL LISTED FIRE STOP SEALANT IN ACCORDANCEWITH THE APPROVED UL LISTED SYSTEM.
B. DOOR OPENINGS SHALL BE PROTECTED BY A UL LISTED (OR EQUAL) DOOR ANDDOOR FRAME. ALL RATED DOORS SHALL BE POSITIVE LATCHING, AUTOMATICCLOSING AND GASKETED TO PREVENT PASSAGE OF SMOKE.
C. MECHANICAL AIR DUCTS PASSING THROUGH RATED CONSTRUCTION SHALL BEPROTECTED BY CALIF. STATE FIRE MARSHAL APPROVED FIRE DAMPERS,INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURES PRINTEDINSTRUCTIONS. PROVIDE ACCESS PANELS WHERE REQUIRED TO RESET / TESTUNITS. ASSEMBLIES INCLUDING SLEEVES SHALL BE APPROVED ALSO BY THELOCAL BUILDING OFFICIAL PRIOR TO INSTALLATION.
D. ALL PENETRATIONS IN RATED WALLS OVER 16 SQ. INCHES SHALL BEBACKWRAPPED WITH 5/8" TYPE 'X' GYP. BOARD. WHERE PENETRATIONS OCCURON OPPOSITE SIDES OF THE WALL, SEPARATE SUCH PENETRATIONS BY MINIMUMOF 24". UNPROTECTED PENETRATIONS (UNDER 16 SQ. IN.) SHALL NOT EXCEED 100SQ IN. TOTAL FOR EACH 100 SQ. FT. OF WALL.
PENETRATIONS THROUGH RATEDASSEMBLIES:1. ALL PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE FIRE-STOPPED BY ONEOF THE FOLLOWING MEANS:
3C - HEAD/ JAMB DETAIL
3B - JOINT DETAIL3D - CORNER DETIAL
2A - BASE
3" = 1'-0"5 - WALL TILE / TRIM
3" = 1'-0"GLASS WALL CLADDING SYSTEM - SILL DETAIL
3A - BASE
10 - TYP. PIPE PENETRATION9 - TYP. PIPE PENETRATION
3" = 1'-0"4 - NON-RATED PARTITION
2E - CORNER DTL - A 2F - CORNER DTL - B
NO. DESCRIPTION DATE1 ADDENDUM 1 4/26/16
5A - WALL TILE PLAN 5B - PLAN AT ACCESSORIES
5C - SECT. AT ACCESSORIES
1
5/5/16
12 GA. HANGER WIRE, 3 TIGHT TURNS.10 OR 12 GA. BRACING WIRE; 4 TIGHT TURNS AT BOTH ENDS
OF WIRE, TYPICAL
12 GAUGE WIRE, TYPICAL - 12 GA. WIRE SHALL BE 0.106INCHES IN DIAMETER CONFORMING TO ASTM A641. 12
GA. WIRE SHALL BE SOFT ANNEALED, GALVANIZED STEELWIRE WITH A CLASS 1 COATING.
1-1/
2" M
AX
NOTE:HANGER OR BRACING WIRE ANCHORS TOTHE STRUCTURE AND SHOULD BE INSTALLEDIN SUCH A MANNER THAT THE DIRECTION OFTHE ANCHOR ALIGNS AS CLOSELY ASPOSSIBLE WITH THE DIRECTION OF THEWIRE.
COMPRESSION STRUT
CROSS RUNNER
(4) 12 GA. BRACING WIRE AT EA.COMPRESSION STRUT W/ MIN. 4 TIGHTTURNS IN 1-1/2" BOTH ENDS OF WIRECONNECT TO MAIN RUNNER
12 GA. VERTICAL HANGER WIRE AT 4'-0" EACH WAY (4' OC. AT MAIN RUNNER)MINIMUM 3 TIGHT TURNS IN 1 1/2" BOTHENDS (TYPICAL)
2" (MAX) FROM BRACING WIRES TOCOMPRESSION STRUT AND CROSS
RUNNER
COMPRESSION STRUTS:COMPRESSION STRUTS SHALL NOT REPLACE HANGER WIRES. MAXIMUM KL/RRATIO OF 200 OR LESS. ATTACH COMPRESSION STRUTS TO MAIN RUNNERSWITHIN TWO (2) INCHES OF CROSS RUNNER. THE ATTACHMENT AT THE TOPSHALL BE CAPABLE OF SUPPORTING FOUR TIMES THE WEIGHT OF THESTRUT.
MAIN RUNNER
4'-0" O.C.8" MAX
4'-0" O.C.
8" MAX4'-0"OR LESS
WALL SLIP
2" LEDGER ANGLE
ACCEPTABLE EXITWAY DETAILS
2" STANDARD LEDGER ANGLE- CONNECT TOSTRUCTURE, NOT FINISH
RUNNER SPLICE
POP RIVET
TYP. HANGER WIRE AT 4'-0" WITH ONE PAIR OF BRACINGWIRES PARALLEL TO WALL AT 12'-0" O.C. SEE SECTIONS
1.9, 1.10 AND 1.11
CONTINUOUS MAIN RUNNERS(SPLICE ALL JOINTS)
POP RIVET
TYP. SPLICE
HANGER WIRE, TYP.
A
SLIP JOINT AT EXITWAYS INTERSECTION OR EXPANSION JOINTFOR CEILING AREA OVER 2500 SQ. FT.
B
1" CLR. SLIP JOINT
TYPICALHANGER
WIRE
1" OVERLAP
RIVET
COVER PLATE
SEE DETAIL8 / A913
3/4" CLR. MIN.
POP RIVET
SEE DETAIL8 / A913
CONNECTED WALL
CROSS RUNNER OR MAIN RUNNER
HANGER WIRE, TYP.
12'-0
"NT
S4'-
0"NT
S
4'-0"NTS
8" MIN.
#12 GAUGE MIN.HANGER WIRE @ 48" O.C. MAX.EACHWAY (MAXIMUM 16 SQUARE FEET SUPPORTED AREA)OR METAL STUD COMPRESSION STRUT, ATTACHED TOSTRUCTURE ABOVE; PROVIDE STRUT AT EACHBRACING ASSEMBLY, TYPICAL.
SCHEMATIC SUSPENDED LAY-IN PANEL CEILING FRAMING PLAN
BRACING ASSEMBLY PER 5A913
ATTACHED (OR FIXED) EDGE
FREE EDGE
FRE
E E
DG
E
ATT
ACH
ED (O
R F
IXE
D) E
DG
E8
A913
8A913
8A913
8A913
MAIN RUNNERS
CR
OSS
RU
NN
ER
S
MAX.45.00°
SCHEMATIC SECTION
METAL T GRIDSUSPENSION SYSTEM
ACOUSTIC CEILING TILE
BLOCKINGBETWEEN STUDS
METAL STUD COMPRESSION STRUT, ATTACHTO STRUCTURE ABOVE; PROVIDE STRUT AT
EACH BRACING ASSEMBLY PER DETAIL5/A913
INTERIOR STUD WALL PER PLAN AND WALLSCHEDULE
A9038
PROVIDE R-19 BATTINSULATION AT ROOM 118.4
6" MAX.
CROSS METAL RUNNER
MAIN METAL RUNNER
SUSPENDED LIGHT FIXTUREATTACHED TO CEILING GRID TO
RESIST HORIZONTAL FORCE EQUALTO WEIGHT OF FIXTURE WITH
SCREWS
#12 STEEL WIRE HANGERS,ATTACH TO PERMANENT
STRUCTURE, TYPICAL 6 PLACES
8" MAXOR NOTE 1 BELOW
ALTERNATE STRUT LOCATION WITHOUT NAIL.NOTCHING PERMITTED ONLY AT RUNNER.
NOTES:1. 1/4 OF THE LENGTH OF THE END RUNNER WHICHEVER IS LESS.2. NAILS AT THE END OF HORIZONTAL STRUTS ARE TO BE PLACED
WITH NAIL HEAD TOWARD CENTERLINE OF SPAN OF STRUT.3. HANGER WIRE NOT REQUIRED FOR CROSS RUNNERS LESS THAN
8" LONG BETWEEN MAIN RUNNER AND WALL.
SLOTTED ANGLE STRUT W/ HORIZ. 6DRINGSHANK NAIL - SEE NOTE 2 BELOW
WALL ANGLE
POP RIVET SEE SECTION 1.5
HANGER WIRE - SEE NOTE 3 BELOW
3/4"
MIN. 3 TIGHT TURNS IN 1-1/2" MAX.
8" MAXOR NOTE 1 BELOW
MAIN RUNNER OR CROSSRUNNER
ACOUSTICAL PANEL
(A) HORIZONTAL STRUT - TYPICAL (SEE SECTION 1.7)
3 TIGHT TURNS IN 1-1/2" MAX.
ACOUSTIC PANEL
(B) TYPICAL HANGER WIRE TO GRID
12 GA. HANGER WIRE
CROSS RUNNER
MAIN RUNNER
FIXED FREE
METAL STUD BRACE AT 48" O.C.
BRACING CONNECTION TOCONCRETE SLAB PERSTRUCTURAL DRAWINGSEE 3/S102
1 MAX.
1
(E) CEILING TO REMAIN
(N) SUSPENDED ACOUSTICAL GRID PANEL
TYP.2"
(N) CEILING HEIGHT PER CEILING PLAN ANDFINISH SCHEDULE
(N) CEILING HEIGHT PER CEILINGPLAN AND FINISH SCHEDULE
AXIOM TRIM
(E) GYP. BOARD WALLSIM: (N) GYP. BD. WALL
(N) SUSPENDED ACOUSTICAL GRID PANEL
(E) CEILING TO REMAIN
1/4"
ALIG
N
WOOD VENEER CEILING PANELS
GYP. BD. CEILING, TYP. - PAINTED
TYP
0' - 2
"
MTL. FRAMING, TYP.
WOOD CEILING TILE
AXION TRIM, TYP.
SUSPENSION CABLE
ACCOUSTIC CEILING TILE
A - AT GYP. BOARD CEILING
B - AT ACC. TILE CEILING
SUSPENSION CABLE
AXION TRIM, TYP.
LIGHT FIXTURE PER ELECTRICAL
WOOD VENEER CEILING PANELS
WOOD VENEER WALL PANELS
LIGHT FIXTURE PER ELECTRICAL
MIN.1/4"
SUSPENSION SYSTEM
1-1/2" 16 GA. COLD ROLLED CHANNEL UP TO A 4'-0" SPAN OR (2) 1-1/2" 16 GA. COLD ROLLEDCHANNELS BACK TO BACK (SEE FIG. A) W/ #10S.M.S. @ 16" O.C. FOR SPANS UP TO 8'.
BACK TO BACK CONDITION: #10 S.M.S.(2) C.R.C
NO. C 9136
REN 9-30-15
LIC
ENSED ARCHITECT
STATE OF CA LIFORNIA
JOS
EPH
ON -WOO
WO
GN
Date
Drawn By
Checked By
Project No.
All id
eas,
desig
ns, a
rrang
emen
ts an
d plan
sind
icated
or re
pres
ented
by th
is dr
awing
are
owne
d by,
and t
he pr
oper
ty of
Jose
ph W
ong
Desig
n Ass
ociat
es, a
nd w
ere c
reate
d,ev
olved
and d
evelo
ped f
or us
e on,
and i
nco
nnec
tion w
ith, th
e spe
cified
proje
ct. N
one
of su
ch id
eas,
desig
ns, a
rrang
emen
ts or
plans
shall
be us
ed w
ithou
t the w
ritten
perm
ission
of Jo
seph
Won
g Des
ignAs
socia
tes. W
ritten
dime
nsion
s on t
hese
draw
ings s
hall h
ave p
rece
denc
e ove
r sca
leddim
ensio
ns. C
ontra
ctors
shall
verify
and b
ere
spon
sible
for al
l dim
ensio
ns an
dco
nditio
ns on
the j
ob, a
nd th
is off
ice m
ust b
eno
tified
of al
l var
iation
s fro
m the
dime
nsion
san
d con
dition
s sho
wn by
thes
e dra
wing
s.
JWD
AA
R C
H I T
E C
T U
R E
/ P
L A
N N
I N
G / I N
T E
R I O
R D
E S
I G
N
Joseph W
ong D
esig
n A
ssocia
tes
235
9 F
ou
rth
Aven
ue
San D
iego,
Ca
lifo
rnia
9210
1-1
606
Pho
ne (
61
9)
233
-67
77
Fax (
61
9)
237
-05
41
REVISIONS:
Scale
Proje
ct Na
me
4/28
/201
6 15
:12:
31
As indicated
A903
CEIL
ING
D ET A
I LS
UNIV
ERSI
TY O
F CA
LIFO
RNIA
SAN
DIE
GO
ROBI
NSON
BUI
LDIN
G CO
MPL
EX
JWDAJWDA
04/18/20163239 | UCSD 4917
9500
GIL
MAN
DRI
VE, L
A JO
LLA,
CA
9209
3
SCHO
OL O
F GP
S - R
ENOV
ATIO
N
6" = 1'-0"9 TYPICAL WIRE TWIST DETAIL 3/8" = 1'-0"5 SUSPENDED CEILING BRACING ASSEMBLY
3" = 1'-0"12 SLIP JOINTS
3" = 1'-0"6 SCHEMATIC LAY-IN PANEL CEILING SEISMIC RESTRAINT
3" = 1'-0"17 TILE CEILING TO WALL
3" = 1'-0"10 LIGHT FIXTURE SEISMIC RESTRAINT
1. GENERAL REQUIREMENTS: THE FOLLOWING REQUIREMENTS APPLY TO CEILING SYSTEMS WHOSETOTAL WEIGHT, INCLUDING CEILING MOUNTED AIR TERMINALS, SERVICES AND LIGHT FIXTURES,DOES NOT EXCEED FOUR (4) PSF. HEAVIER SYSTEMS, AND THOSE SUPPORTING LATERAL LOADSFROM PARTITIONS, WILL REQUIRE SPECIAL DESIGN DETAILS.
1.1 #12 GAGE WIRE SHALL BE 0.106 INCHES IN DIAMETER CONFORMING TO ASTM A641. #12 GAGE WIRESHALL BE SOFT ANNEALED, GALVANIZED STEEL WIRE WITH A CLASS 1 COATING.
1.2 #12 GAGE HANGER WIRES MAY BE USED FOR UP TO AND INCLUDING 4 FT. BY 4 FT. GRID SPACINGAND SHALL BE ATTACHED TO MAIN RUNNERS.
1.3 PROVIDE #12 GAGE HANGER WIRES AT THE ENDS OF ALL MAIN AND CROSS RUNNERS WITHIN EIGHT(8) INCHES OF THE SUPPORT OR WITHIN ONE-FOURTH (1/4) OF THE LENGTH OF THE END TEE,WHICHEVER IS LEAST, FOR THE PERIMETER OF THE CEILING AREA. SEE DETAIL 8/A913. PERIMETERWIRES ARE NOT REQUIRED WHEN THE LENGTH OF THE END TEE IS EIGHT (8) INCHES OR LESS.
1.4 PROVIDE TRAPEZE OR OTHER SUPPLEMENTARY SUPPORT MEMBERS AT OBSTRUCTIONS TOTYPICAL HANGER SPACING. SEE DET 9/A914. PROVIDE ADDITIONAL HANGERS, STRUTS OR BRACESAS REQUIRED AT ALL CEILING BREAKS, SOFFITS, OR DISCONTINUOUS AREAS. HANGER WIRES THATARE MORE THAN 1 (HORIZONTAL) IN 6 (VERTICAL) OUT OF PLUMB ARE TO HAVE COUNTER-SLOPINGWIRES.
1.5 CEILING GRID MEMBERS SHALL BE ATTACHED TO TWO (2) ADJACENT WALLS PER ASCE 7-05,SECTION 13.5.6.2(B). CEILING GRID MEMBERS SHALL BE AT LEAST 3/4 INCH CLEAR OF OTHER WALLS.IF WALLS RUN DIAGONALLY TO CEILING GRID SYSTEM RUNNERS, ONE END OF MAIN AND CROSSRUNNERS SHOULD BE FREE, AND A MINIMUM OF 3/4 INCH CLEAR OF WALL.
1.6 THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL BE NOT LESS THAN 2 INCHES.1.7 AT THE PERIMETER OF THE CEILING AREA WHERE MAIN OR CROSS RUNNERS ARE NOT CONNECTED
TO THE ADJACENT WALL, PROVIDE INTERCONNECTION BETWEEN THE RUNNERS AT THE FREE ENDTO PREVENT LATERAL SPREADING. A METAL STRUT OR A #16 GAGE WIRE WITH A POSITIVEMECHANICAL CONNECTION TO THE RUNNER MAY BE USED. WHERE THE PERPENDICULAR DISTANCEFROM THE WALL TO THE FIRST PARALLEL RUNNER IS 8 INCHES OR LESS, THIS INTERLOCK IS NOTREQUIRED.
1.8 EXPANSION JOINTS SHALL BE PROVIDED IN THE CEILING AT INTERSECTIONS OF CORRIDORS AND ATJUNCTIONS OF CORRIDORS WITH LOBBIES OR OTHER SIMILAR AREAS. SEE DETAIL 12B / A913.
1.9 PROVIDE LATERAL-FORCE BRACING ASSEMBLIES CONSISTING OF A COMPRESSION STRUT ANDFOUR (4) #12 GAGE SPLAYED BRACING WIRES ORIENTED 90 DEGREES FROM EACH OTHER (SEEDETAIL 5 / A913).
1.10 PROVIDE BRACING ASSEMBLIES AT LOCATIONS NOT MORE THAN ONE HALF (1/2) THE CALCULATEDSPACING IN EACH DIRECTION FROM EACH PERIMETER WALL AND AT THE EDGES OF ANY CHANGE INELEVATION OF THE CEILING.
1.10a BRACING ASSEMBLIES SHALL BE SPACED AT A MAXIMUM OF 12 FEET BY 12 FEET ON CENTERS FORSCHOOL BUILDINGS AND 8 FEET BY 12 FEET ON CENTERS FOR ESSENTIAL SERVICES BUILDINGS.
1.10b THE MAXIMUM SLENDERNESS RATIO (KL/R) OF THE COMPRESSION STRUT SHALL BE 200 OR LESS.1.11 THE SLOPE OF BRACING WIRES SHALL NOT EXCEED 45 DEGREES FROM THE PLANE OF THE CEILING
AND WIRES SHALL BE TAUT. SPLICES IN WIRES ARE NOT PERMITTED WITHOUT SPECIAL DSAAPPROVAL.
1.12 COMPRESSION STRUTS SHALL NOT BE MORE THAN 1 (HORIZONTAL) IN 6 (VERTICAL) OUT OF PLUMB.1.13 SUSPENDED ACOUSTICAL CEILING SYSTEMS WITH A CEILING AREA OF 144 SQUARE FEET OR LESS,
AND FIRE RATED SUSPENDED ACOUSTICAL CEILING SYSTEMS WITH A CEILING AREA OF 96 SQUAREFEET OR LESS, SURROUNDED BY WALLS WHICH CONNECT DIRECTLY TO THE STRUCTURE ABOVE ORWALLS INDEPENDENTLY BRACED ABOVE CEILING TO STRUCTURE ABOVE, DO NOT REQUIREBRACING ASSEMBLIES WHEN ATTACHED TO TWO ADJACENT WALLS.
1.14 FOR CEILING AREAS EXCEEDING 2500 SQUARE FEET A SEISMIC SEPARATION JOINT SHALL BEPROVIDED IN ACCORDANCE WITH DETAIL 12A / A9.13 TO DIVIDE THE CEILING INTO AREAS NOTEXCEEDING 2500 SQUARE FEET. ALTERNATIVELY, STRUCTURAL ANALYSIS SHALL BE PERFORMED TODEMONSTRATE COMPLIANCE WITH ASTM E580-08 SECTION 5.2.9.
1.15 PENETRATIONS THROUGH THE CEILING FOR SPRINKLER HEADS AND OTHER SIMILAR DEVICES THATARE NOT INTEGRALLY TIED TO THE CEILING SYSTEM IN THE LATERAL DIRECTION SHALL HAVE A TWO(2) INCH OVERSIZED RING, SLEEVE OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FREEMOVEMENT OF ONE (1) INCH IN ALL HORIZZONTAL DIRECTIONS. ALTERNATIVELY, PER ASTM E580SECTION 5.2.8.8, A FLEXIBLE SPRINKLER HOSE FITTING THAT CAN ACCOMMODATE 1 INCH OF CEILINGMOVEMENT SHALL BE PERMITTED TO BE USED IN LIE OF THE OVERSIZED RING, SLEEVE ORADAPTER.
1.16 FASTEN #12 HANGER WIRES WITH NOT LESS THAN THREE (3) TIGHT TURNS IN 3 INCHES. HANGERWIRE LOOPS SHALL BE TIGHTLY WRAPPED AND SHARPLY BENT TO PREVENT ANY VERTICALMOVEMENT OR ROTATION OF THE MEMBER WITHIN THE LOOPS (SEE ASTM E580, SECTION5.2.7.2).FASTEN #10 OR #12 BRACING WIRES WITH FOUR (4) TIGHT TURNS. MAKE ALL TIGHT TURNSWITHIN A DISTANCE OF 1-1/2 INCHES. HANGER OR BRACING WIRE ANCHORS TO THE STRUCTURESHOULD BE INSTALLED IN SUCH A MANNER THAT THE DIRECTION OF THE ANCHOR ALIGNS ASCLOSELY AS POSSIBLE WITH THE DIRECTION OF THE WIRE. NOTE: WIRE TURNS MADE BY MACHINEWHERE BOTH STRANDS HAVE BEEN DEFORMED OR BENT IN WRAPPING CAN WAIVE THE 1-1/2 INCHREQUIREMENT, BUT THE NUMBER OF TURNS SHOULD BE MAINTAINED, AND BE AS TIGHT ASPOSSIBLE.
1.17 SEPARATE ALL CEILING HANGER AND BRACING WIRES AT LEAST SIX (6) INCHES FROM ALLUNBRACED DUCTS, PIPES, CONDUIT, ETC.
1.18 WHEN DRILLED-IN CONCRETE ANCHORS OR SHOT-IN ANCHORS ARE USED IN REINFORCEDCONCRETE FOR HANGER WIRES, 1 OUT OF 10 WIRE/ANCHOR ASSEMBLIES MUST BE FIELD TESTEDFOR 200 LBS. IN TENSION. WHEN DRILLED-IN CONCRETE ANCHORS ARE USED FOR BRACING WIRES,1 OUT OF 2 WIRE/ANCHOR ASSEMBLIES MUST BE FIELD TESTED FOR 440 LBS. IN TENSION IN THEDIRECTION OF THE WIRE. SHOT-IN ANCHORS IN CONCRETE ARE NOT PERMITTED FOR BRACINGWIRES. NOTE: DRILLED-IN OR SHOT-IN ANCHORS REQUIRE SPECIAL DSA APPROVAL PRIOR TO USEIN PRESTRESSED CONCRETE.
1.19 ATTACH ALL LIGHT FIXTURES AND CEILING MOUNTED AIR TERMINALS, TO THE CEILING GRIDRUNNERS TO RESIST A HORIZONTAL FORCE EQUAL TO THE WEIGHT OF THE FIXTURES. SCREWS ORAPPROVED FASTENERS ARE REQUIRED.
1.20 FLUSH OR RECESSED LIGHT FIXTURES, WEIGHING LESS THAN 56 LBS. AND MECHANICAL TERMINALSAND SERVICES, WEIGHING LESS THAN 20 LBS., MAY BE SUPPORTED DIRECTLY ON THE RUNNERS OFA HEAVY DUTY GRID SYSTEM BUT, IN ADDITION, THEY MUST HAVE A MINIMUM OF TWO (2) #12 GAGESLACK SAFETY WIRES ATTACHED TO THE FIXTURE AT DIAGONAL CORNERS AND ANCHORED TO THESTRUCTURE ABOVE. ALL 4 FT. X 4 FT. LIGHT FIXTURES MUST HAVE SLACK SAFETY WIRES AT EACHCORNER.ALL FLUSH OR RECESSED LIGHT FIXTURES WEIGHING 56 LBS. OR MORE AND MECHANICALTERMINALS AND SERVICES, WEIGHING 20 LBS. OR MORE, MUST BE INDEPENDENTLY SUPPORTED BYNOT LESS THAN FOUR (4) TAUT #12 GAGE WIRES, EACH ATTACHED TO THE FIXTURE AND TO THESTRUCTURE ABOVE.THE FOUR (4) TAUT #12 GAGE WIRES, INCLUDING THEIR ATTACHMENT TO THE STRUCTURE ABOVE,MUST BE CAPABLE OF SUPPORTING FOUR (4) TIMES THE WEIGHT OF THE UNIT.FLUSH OR RECESSED LIGHT FIXTURES, WEIGHING LESS THAN 56 LBS. AND MECHANICAL TERMINALSAND SERVICES, WEIGHING LESS THAN 20 LBS., MAY BE SUPPORTED DIRECTLY ON THE RUNNERS OFA HEAVY DUTY GRID SYSTEM BUT, IN ADDITION, THEY MUST HAVE A MINIMUM OF TWO (2) #12 GAGESLACK SAFETY WIRES ATTACHED TO THE FIXTURE AT DIAGONAL CORNERS AND ANCHORED TO THESTRUCTURE ABOVE. ALL 4 FT. X 4 FT. LIGHT FIXTURES MUST HAVE SLACK SAFETY WIRES AT EACHCORNER.ALL FLUSH OR RECESSED LIGHT FIXTURES WEIGHING 56 LBS. OR MORE AND MECHANICALTERMINALS AND SERVICES, WEIGHING 20 LBS. OR MORE, MUST BE INDEPENDENTLY SUPPORTED BYNOT LESS THAN FOUR (4) TAUT #12 GAGE WIRES, EACH ATTACHED TO THE FIXTURE AND TO THESTRUCTURE ABOVE.THE FOUR (4) TAUT #12 GAGE WIRES, INCLUDING THEIR ATTACHMENT TO THE STRUCTURE ABOVE,MUST BE CAPABLE OF SUPPORTING FOUR (4) TIMES THE WEIGHT OF THE UNIT.
1.21 SUPPORT SURFACE MOUNTED LIGHT FIXTURES BY AT LEAST TWO POSITIVE DEVICES WHICHSURROUND THE CEILING RUNNER AND WHICH ARE EACH SUPPORTED FROM THE STRUCTUREABOVE BY A #12 GAGE WIRE. SPRING CLIPS OR CLAMPS THAT CONNECT ONLY TO THE RUNNER ARENOT ACCEPTABLE. PROVIDE ADDITIONAL SUPPORTS WHEN LIGHT FIXTURES ARE 8 FT. OR LONGER.MAXIMUM SPACING BETWEEN SUPPORTS SHALL NOT EXCEED 8 FEET.
1.22 SUPPORT PENDANT MOUNTED LIGHT FIXTURES DIRECTLY FROM THE STRUCTURE ABOVE WITHHANGER WIRES OR CABLES PASSING THROUGH EACH PENDANT HANGER AND CAPABLE OFSUPPORTING TWO (2) TIMES THE WEIGHT OF THE FIXTURE. A BRACING ASSEMBLY, PER DETAIL 5 /A913, IS REQUIRED WHERE THE PENDANT HANGER PENETRATES THE CEILING. SPECIAL DETAILSARE REQUIRED TO ATTACH THE PENDANT HANGER TO THE BRACING ASSEMBLY TO TRANSMITHORIZONTAL FORCE. IF THE PENDANT MOUNTED LIGHT FIXTURE IS DIRECTLY AND INDEPENDENTLYBRACED BELOW THE CEILING, I.E. AIRCRAFT CABLES TO WALLS, THEN BRACE ASSEMBLY IS NOTREQUIRED ABOVE THE CEILING. SEE IR 16-9 FOR ADDITIONAL REQUIREMENT FOR PENDENTMOUNTED FIXTURES.
1.23 THE CEILING GRID SYSTEM MUST BE RATED AS HEAVY DUTY AS DEFINED BY ASTM C635.1.24 METAL PANELS AND PANELS WEIGHING MORE THAN 1/2 PSF, OTHER THAN MINERAL FIBER
ACOUSTICAL TILE, ARE TO BE POSITIVELY ATTACHED TO THE CEILING SUSPENSION RUNNERS.1.25 ALL LIGHT-WEIGHT MISCELLANEOUS DEVICES, SUCH AS STROBE LIGHTS, SPEAKERS, ETC., SHALL BE
ATTACHED TO THE CEILING GRID PER SECTION 7.1 OF IR. IN ADDITION, DEVICES WEIGHING MORETHAN 10 LBS SHALL HAVE A #12 SLACK SAFETY WIRE ANCHORED TO THE STRUCTURE ABOVE.DEVICES WEIGHING MORE THAT 20 LBS SHALL BE SUPPORTED FROM THE STRUCTURE ABOVE PERSECTION 7.3 OF IR.
3" = 1'-0"8 CEILING HANGER DETAILS
METAL SUSPENSION SYSTEMS FOR LAY-IN PANEL CEILINGS
NOTE: SEE ALSO DSA IR 25-2.10 METAL SUSP. SYSTEMS FOR LAY-IN PANEL CEILINGS.
3" = 1'-0"13 WALL BRACING TO SLAB
3" = 1'-0"15 GYPSUM / ACOUSTICAL SOFFIT
3" = 1'-0"16 GYPSUM / ACOUSTICAL SOFFIT
3" = 1'-0"14 CEILING TRANSITION DETAIL 3" = 1'-0"18 CEILING/ WALL DETAIL
12" = 1'-0"19 TRAPEZE DETAIL
NO. DESCRIPTION DATE1 ADDENDUM 1 4/26/16
1
5/5/16
5/5/16
5/5/16
5/5/16