context plan (nts) · batman st. extension service lane currong st. batman st. extension service...
TRANSCRIPT
CONTEXT PLAN (NTS)
ANALYTICAL DIAGRAMS (NTS)
COOYONG ST.
TERRITORY PLAN CONTROLS
BRADDON PRECINCT & MAP
Height of BuildingsNo stage 2 North 'A' site specific height controls within the Braddon Precinct & Map code.Except where stated, building heights in RZ5 are regulated by the Multi Unit Housing Development Code.
MULTI-UNIT HOUSING DEVELOPMENT CODE
Number of Storeys – RZ5Rule 22 In RZ5, the maximum number of storeys is: a) for that part of the building within 50m of the boundaries of blocks in RZ1, RZ2 or RZ3 - 3 b) for that part of the building within 40m of the boundaries of blocks in CFZ, PRZ1 or PRZ2 -3 c) for that part of the building within 30m of the boundaries of blocks in RZ4 - 4 d) in all other cases – 6. Roof top plant that is set back and screened from the street is not included in the number of storeys. However we would be arguing that the development achieves Criteria 22 below.
TERRITORY PLAN CONTROLS
BRADDON PRECINCT & MAPHeight of BuildingsNo stage 2 North 'A' site speci�c height controls within the Braddon Precinct & Map code.Except where stated, building heights in RZ5 are regulated by the Multi Unit Housing Development Code.
Plot Ratio
Rule 39This rule applies to blocks and sections identi�ed in Figure 8.The maximum plot ratio is 160% for block Bb (stage 2 north 'A' site).However we would be arguing that the development achieves Criteria 39 below.
Criteria 39Plot ratios are consistent with the desired character of the Cooyong street urban renewal area.
MULTI-UNIT HOUSING DEVELOPMENT CODENumber of Storeys – RZ5Rule 22�In RZ5, the maximum number of storeys is: 1. a) for that part of the building within 50m of the boundaries of blocks in RZ1, RZ2 or RZ3 - 3 2. b) for that part of the building within 40m of the boundaries of blocks in CFZ, PRZ1 or PRZ2 -3 3. c) for that part of the building within 30m of the boundaries of blocks in RZ4 - 4 4. d) in all other cases – 6. Roof top plant that is set back and screened from the street is not included in the number of storeys. However we would be arguing that the development achieves Criteria 22 below.
Criteria 22Buildings achieve all of the following:a) consistency with the desired characterb) reasonable solar access to dwellings on adjoining residential blocks and their associated private open space.
Rule 24 - This is mandatoryMaximum height of building is: a) in RZ3 – 9.5m b) in RZ4 – 12.5m c) in RZ5 – 21.5m.
Front SetbackRule 29Front boundary setbacks comply with Table A5 which states 6m to lower and upper �oor levels.However we would be arguing that the development achieves Criteria 29 below.
Criteria 29Front boundary setbacks achieve all of the following:a) consistency with the desired characterb) reasonable amenity for residentsc) su�cient space for street trees to grow to maturity.
Side and Rear Setbacks - for buildings with 4 or more storeysRule 95In RZ5 side and rear boundary setbacks are to comply with Table B1 which states a minimum side setback of 6m for unscreened elements and a minimum rear setback of 6m for unscreened elements. However we would be arguing that the development achieves Criteria 95 below.
Criteria 95Buildings and other structures are sited to achieve all of the following:a) consistency with the desired characterb) reasonable separation between adjoining developmentsc) reasonable privacy for dwellings on adjoining residential blocksd) reasonable privacy for principal private open space on adjoining residential blockse) reasonable solar access to dwellings on adjoining residential blocks and their associated principal private open space.
STAGE 2 NORTH ‘A’
BUILDING HEIGHT
STAGE 2 NORTH ‘B’
MAX.
3 ST
OREY
RULE
‘B’
MAX. 3 STOREY
MAX. 6 STOREY
RULE ‘A’
CURR
ONG
ST.
BATMAN ST. EXTENTION
CANBERRA CENTREAPPROX. 13 M HEIGHT
15 M
24.1 M 27.1 M
APPROVED S52 SOUTH HEIGHT : 21 M
BATMAN ST. BATMAN ST.
PETRIE ST.
BATMAN ST. EXTENTION
APPROVED S52 SOUTH HEIGHT : 39.1M
SERV
ICE
LANE
PRZ1
RZ1
MAX. 6 STOREY
RULE ‘D’
CANBERRA CENTREAPPROX. 20 M HEIGHT
PROPOSED 21 M 7 STOREY BUILDING
PROPOSED 15M PROPOSED 21M 7 STOREY BUILDING
DEMOLISHED 8 STOREY BUILDING
CURRONG ST.
COOYONG ST.
PETRIE ST.
BATMAN ST. EXTENTION
CURRONG ST.
CRITERIA C22a) consistency with the desired character
The proposed development meets the desired character.
b) reasonable solar access to dwellings on adjoining residential blocks and their associated private open space
The proposed development does not block solar access to dwellings on adjoining residential blocks and their associated private open space
RESIDENTIAL ZONE DEVELOPMENT CODEC55In all residential zones, where the number of storeys in a lawfully constructed building exceeds the maximum stipulated in the relevant code, a new building or buildings with no more storeys than the existing building may be permitted provided there are no additional adverse impacts on adjoining properties including but not limited to, solar access.
The proposed number of storeys is less than the demolished building
COOYONG ST.
TERRITORY PLAN CONTROLS
BRADDON PRECINCT & MAP
Height of BuildingsNo stage 2 North 'A' site specific height controls within the Braddon Precinct & Map code.Except where stated, building heights in RZ5 are regulated by the Multi Unit Housing Development Code.
MULTI-UNIT HOUSING DEVELOPMENT CODE
Number of Storeys – RZ5Rule 22 In RZ5, the maximum number of storeys is: a) for that part of the building within 50m of the boundaries of blocks in RZ1, RZ2 or RZ3 - 3 b) for that part of the building within 40m of the boundaries of blocks in CFZ, PRZ1 or PRZ2 -3 c) for that part of the building within 30m of the boundaries of blocks in RZ4 - 4 d) in all other cases – 6. Roof top plant that is set back and screened from the street is not included in the number of storeys. However we would be arguing that the development achieves Criteria 22 below.
TERRITORY PLAN CONTROLS
BRADDON PRECINCT & MAPHeight of BuildingsNo stage 2 North 'A' site speci�c height controls within the Braddon Precinct & Map code.Except where stated, building heights in RZ5 are regulated by the Multi Unit Housing Development Code.
Plot Ratio
Rule 39This rule applies to blocks and sections identi�ed in Figure 8.The maximum plot ratio is 160% for block Bb (stage 2 north 'A' site).However we would be arguing that the development achieves Criteria 39 below.
Criteria 39Plot ratios are consistent with the desired character of the Cooyong street urban renewal area.
MULTI-UNIT HOUSING DEVELOPMENT CODENumber of Storeys – RZ5Rule 22�In RZ5, the maximum number of storeys is: 1. a) for that part of the building within 50m of the boundaries of blocks in RZ1, RZ2 or RZ3 - 3 2. b) for that part of the building within 40m of the boundaries of blocks in CFZ, PRZ1 or PRZ2 -3 3. c) for that part of the building within 30m of the boundaries of blocks in RZ4 - 4 4. d) in all other cases – 6. Roof top plant that is set back and screened from the street is not included in the number of storeys. However we would be arguing that the development achieves Criteria 22 below.
Criteria 22Buildings achieve all of the following:a) consistency with the desired characterb) reasonable solar access to dwellings on adjoining residential blocks and their associated private open space.
Rule 24 - This is mandatoryMaximum height of building is: a) in RZ3 – 9.5m b) in RZ4 – 12.5m c) in RZ5 – 21.5m.
Front SetbackRule 29Front boundary setbacks comply with Table A5 which states 6m to lower and upper �oor levels.However we would be arguing that the development achieves Criteria 29 below.
Criteria 29Front boundary setbacks achieve all of the following:a) consistency with the desired characterb) reasonable amenity for residentsc) su�cient space for street trees to grow to maturity.
Side and Rear Setbacks - for buildings with 4 or more storeysRule 95In RZ5 side and rear boundary setbacks are to comply with Table B1 which states a minimum side setback of 6m for unscreened elements and a minimum rear setback of 6m for unscreened elements. However we would be arguing that the development achieves Criteria 95 below.
Criteria 95Buildings and other structures are sited to achieve all of the following:a) consistency with the desired characterb) reasonable separation between adjoining developmentsc) reasonable privacy for dwellings on adjoining residential blocksd) reasonable privacy for principal private open space on adjoining residential blockse) reasonable solar access to dwellings on adjoining residential blocks and their associated principal private open space.
STAGE 2 NORTH ‘A’
BUILDING HEIGHT
STAGE 2 NORTH ‘B’
MAX.
3 ST
OREY
RULE
‘B’
MAX. 3 STOREY
MAX. 6 STOREY
RULE ‘A’
CURR
ONG
ST.
BATMAN ST. EXTENTION
CANBERRA CENTREAPPROX. 13 M HEIGHT
15 M
24.1 M 27.1 M
APPROVED S52 SOUTH HEIGHT : 21 M
BATMAN ST. BATMAN ST.
PETRIE ST.
BATMAN ST. EXTENTION
APPROVED S52 SOUTH HEIGHT : 39.1M
SERV
ICE
LANE
PRZ1
RZ1
MAX. 6 STOREY
RULE ‘D’
CANBERRA CENTREAPPROX. 20 M HEIGHT
PROPOSED 21 M 7 STOREY BUILDING
PROPOSED 15M PROPOSED 21M 7 STOREY BUILDING
DEMOLISHED 8 STOREY BUILDING
CURRONG ST.
COOYONG ST.
PETRIE ST.
BATMAN ST. EXTENTION
CURRONG ST.
CRITERIA C22a) consistency with the desired character
The proposed development meets the desired character.
b) reasonable solar access to dwellings on adjoining residential blocks and their associated private open space
The proposed development does not block solar access to dwellings on adjoining residential blocks and their associated private open space
RESIDENTIAL ZONE DEVELOPMENT CODEC55In all residential zones, where the number of storeys in a lawfully constructed building exceeds the maximum stipulated in the relevant code, a new building or buildings with no more storeys than the existing building may be permitted provided there are no additional adverse impacts on adjoining properties including but not limited to, solar access.
The proposed number of storeys is less than the demolished building
CANBERRA CENTREAPPROX. 20 M HEIGHT
PLOT BbPROPOSED 18 M
7 STOREY BUILDING
ENCROACHMENT INTO SETBACKS
GLAZING LINE
BUILDING ENVELOPE OF FUTURE DEVELOPMENT
CURR
ONG
STRE
ET
BATMAN STREETEXTENSION
PZR1 POCKETPARK
SERV
ICE
LANE
WAY
CURR
ONG
STRE
ET
COOY
ONG
STRE
ET
BATMAN STREETEXTENSION
PZR1 POCKETPARK
SERV
ICE
LANE
WAY
CURR
ONG
STRE
ET
COOY
ONG
STRE
ET
BATMAN STREETEXTENSION
PZR1 POCKETPARK
SERV
ICE
LANE
WAY
CURR
ONG
ST.
CURR
ONG
ST.
CURR
ONG
ST.
(FRO
NT)
COOY
ONG
ST.
SERV
ICE
LANE
SERV
ICE
LANE
SERV
ICE
LANE
TERRITORY PLAN CONTROLS
BRADDON PRECINCT & MAPHeight of BuildingsNo stage 2 North 'A' site speci�c height controls within the Braddon Precinct & Map code.Except where stated, building heights in RZ5 are regulated by the Multi Unit Housing Development Code.
Plot Ratio
Rule 39This rule applies to blocks and sections identi�ed in Figure 8.The maximum plot ratio is 160% for block Bb (stage 2 north 'A' site).However we would be arguing that the development achieves Criteria 39 below.
Criteria 39Plot ratios are consistent with the desired character of the Cooyong street urban renewal area.
MULTI-UNIT HOUSING DEVELOPMENT CODENumber of Storeys – RZ5Rule 22�In RZ5, the maximum number of storeys is: 1. a) for that part of the building within 50m of the boundaries of blocks in RZ1, RZ2 or RZ3 - 3 2. b) for that part of the building within 40m of the boundaries of blocks in CFZ, PRZ1 or PRZ2 -3 3. c) for that part of the building within 30m of the boundaries of blocks in RZ4 - 4 4. d) in all other cases – 6. Roof top plant that is set back and screened from the street is not included in the number of storeys. However we would be arguing that the development achieves Criteria 22 below.
Criteria 22Buildings achieve all of the following:a) consistency with the desired characterb) reasonable solar access to dwellings on adjoining residential blocks and their associated private open space.
Rule 24 - This is mandatoryMaximum height of building is: a) in RZ3 – 9.5m b) in RZ4 – 12.5m c) in RZ5 – 21.5m.
Front SetbackRule 29Front boundary setbacks comply with Table A5 which states 6m to lower and upper �oor levels.However we would be arguing that the development achieves Criteria 29 below.
Criteria 29Front boundary setbacks achieve all of the following:a) consistency with the desired characterb) reasonable amenity for residentsc) su�cient space for street trees to grow to maturity.
Side and Rear Setbacks - for buildings with 4 or more storeysRule 95In RZ5 side and rear boundary setbacks are to comply with Table B1 which states a minimum side setback of 6m for unscreened elements and a minimum rear setback of 6m for unscreened elements. However we would be arguing that the development achieves Criteria 95 below.
Criteria 95Buildings and other structures are sited to achieve all of the following:a) consistency with the desired characterb) reasonable separation between adjoining developmentsc) reasonable privacy for dwellings on adjoining residential blocksd) reasonable privacy for principal private open space on adjoining residential blockse) reasonable solar access to dwellings on adjoining residential blocks and their associated principal private open space.
SETBACKS
PLOT Bb
SINGLE / TWO STOREY DWELLING
SITE BOUNDARYSITE BOUNDARY
FRONT & REAR SETBACK
SIDE SETBACK
LOWER FLOOR SETBACK
BUILDING LINE
UPPER FLOOR SETBACK4M
6M
6M
BATMAN ST. EXTENTION
BATMAN ST. EXTENTION
The development provides reasonable amenity for residentsThe development gives sufficient space for street trees to grow to maturity even though the balconies encroach the front setback by 2m.
The development provides reasonable privacy for principal priavate open space on adjoining residential blocksThe development gives reasonable solar access to dwellings on adjoining residential blocks and their associated principal private open space.
TERRITORY PLAN CONTROLS
MULTI UNIT HOUSING DEVELOPMENT CODE
Rule 29Front Boundary Setbacks comply with Table A5.
Floor level Blocks in subdivision approved on or after 18 October 1993lower floor level 4mupper floor level 6m Rule 30Side and rear boundary setbacks for RZ5 comply with Table A7
Minimum side boundary setback within the rear zonelower floor level - 3munscreened elementupper floor level - 6munscreened element
3M
6M
3M
6M
25M 28M
3M
6M
4M3M
6M
6M
C29Front boundary setbacks achieve all of the following:a) consistency with the desired characterb) reasonable amenity for residentsc) sufficient space for street trees to grow to maturity
C30Buildings and other structures are sited to achieve all of the following:a) consistency with the desired character b) reasonable separation between adjoining developmentsc) reasonable privacy for dwellings on adjoining residential blocksd) reasonable privacy for principal priavate open space on adjoining residential blockse) reasonable solar access to dwellings on adjoining residential blocks and their associated principal private open space.
21 JUNE AT 9 am 21 JUNE AT 12 pm
30M
21 JUNE AT 3 pm
CURR
ONG
ST.
BATMAN ST. EXTENSION
SERV
ICE
LANE
CURR
ONG
ST.
BATMAN ST. EXTENSION
SERV
ICE
LANE
CURR
ONG
ST.
BATMAN ST. EXTENSION
SERV
ICE
LANE
CANBERRA CENTREAPPROX. 20 M HEIGHT
PLOT BbPROPOSED 18 M
7 STOREY BUILDING
ENCROACHMENT INTO SETBACKS
GLAZING LINE
BUILDING ENVELOPE OF FUTURE DEVELOPMENT
CURR
ONG
STRE
ET
BATMAN STREETEXTENSION
PZR1 POCKETPARK
SERV
ICE
LANE
WAY
CURR
ONG
STRE
ET
COOY
ONG
STRE
ET
BATMAN STREETEXTENSION
PZR1 POCKETPARK
SERV
ICE
LANE
WAY
CURR
ONG
STRE
ET
COOY
ONG
STRE
ET
BATMAN STREETEXTENSION
PZR1 POCKETPARK
SERV
ICE
LANE
WAY
CURR
ONG
ST.
CURR
ONG
ST.
CURR
ONG
ST.
(FRO
NT)
COOY
ONG
ST.
SERV
ICE
LANE
SERV
ICE
LANE
SERV
ICE
LANE
TERRITORY PLAN CONTROLS
BRADDON PRECINCT & MAPHeight of BuildingsNo stage 2 North 'A' site speci�c height controls within the Braddon Precinct & Map code.Except where stated, building heights in RZ5 are regulated by the Multi Unit Housing Development Code.
Plot Ratio
Rule 39This rule applies to blocks and sections identi�ed in Figure 8.The maximum plot ratio is 160% for block Bb (stage 2 north 'A' site).However we would be arguing that the development achieves Criteria 39 below.
Criteria 39Plot ratios are consistent with the desired character of the Cooyong street urban renewal area.
MULTI-UNIT HOUSING DEVELOPMENT CODENumber of Storeys – RZ5Rule 22�In RZ5, the maximum number of storeys is: 1. a) for that part of the building within 50m of the boundaries of blocks in RZ1, RZ2 or RZ3 - 3 2. b) for that part of the building within 40m of the boundaries of blocks in CFZ, PRZ1 or PRZ2 -3 3. c) for that part of the building within 30m of the boundaries of blocks in RZ4 - 4 4. d) in all other cases – 6. Roof top plant that is set back and screened from the street is not included in the number of storeys. However we would be arguing that the development achieves Criteria 22 below.
Criteria 22Buildings achieve all of the following:a) consistency with the desired characterb) reasonable solar access to dwellings on adjoining residential blocks and their associated private open space.
Rule 24 - This is mandatoryMaximum height of building is: a) in RZ3 – 9.5m b) in RZ4 – 12.5m c) in RZ5 – 21.5m.
Front SetbackRule 29Front boundary setbacks comply with Table A5 which states 6m to lower and upper �oor levels.However we would be arguing that the development achieves Criteria 29 below.
Criteria 29Front boundary setbacks achieve all of the following:a) consistency with the desired characterb) reasonable amenity for residentsc) su�cient space for street trees to grow to maturity.
Side and Rear Setbacks - for buildings with 4 or more storeysRule 95In RZ5 side and rear boundary setbacks are to comply with Table B1 which states a minimum side setback of 6m for unscreened elements and a minimum rear setback of 6m for unscreened elements. However we would be arguing that the development achieves Criteria 95 below.
Criteria 95Buildings and other structures are sited to achieve all of the following:a) consistency with the desired characterb) reasonable separation between adjoining developmentsc) reasonable privacy for dwellings on adjoining residential blocksd) reasonable privacy for principal private open space on adjoining residential blockse) reasonable solar access to dwellings on adjoining residential blocks and their associated principal private open space.
SETBACKS
PLOT Bb
SINGLE / TWO STOREY DWELLING
SITE BOUNDARYSITE BOUNDARY
FRONT & REAR SETBACK
SIDE SETBACK
LOWER FLOOR SETBACK
BUILDING LINE
UPPER FLOOR SETBACK4M
6M
6M
BATMAN ST. EXTENTION
BATMAN ST. EXTENTION
The development provides reasonable amenity for residentsThe development gives sufficient space for street trees to grow to maturity even though the balconies encroach the front setback by 2m.
The development provides reasonable privacy for principal priavate open space on adjoining residential blocksThe development gives reasonable solar access to dwellings on adjoining residential blocks and their associated principal private open space.
TERRITORY PLAN CONTROLS
MULTI UNIT HOUSING DEVELOPMENT CODE
Rule 29Front Boundary Setbacks comply with Table A5.
Floor level Blocks in subdivision approved on or after 18 October 1993lower floor level 4mupper floor level 6m Rule 30Side and rear boundary setbacks for RZ5 comply with Table A7
Minimum side boundary setback within the rear zonelower floor level - 3munscreened elementupper floor level - 6munscreened element
3M
6M
3M
6M
25M 28M
3M
6M
4M3M
6M
6M
C29Front boundary setbacks achieve all of the following:a) consistency with the desired characterb) reasonable amenity for residentsc) sufficient space for street trees to grow to maturity
C30Buildings and other structures are sited to achieve all of the following:a) consistency with the desired character b) reasonable separation between adjoining developmentsc) reasonable privacy for dwellings on adjoining residential blocksd) reasonable privacy for principal priavate open space on adjoining residential blockse) reasonable solar access to dwellings on adjoining residential blocks and their associated principal private open space.
21 JUNE AT 9 am 21 JUNE AT 12 pm
30M
21 JUNE AT 3 pm
CURR
ONG
ST.
BATMAN ST. EXTENSION
SERV
ICE
LANE
CURR
ONG
ST.
BATMAN ST. EXTENSION
SERV
ICE
LANE
CURR
ONG
ST.
BATMAN ST. EXTENSION
SERV
ICE
LANE
BUILDING HEIGHT/MASSING SETBACKS
SHADOW DIAGRAMS
POSSIBLE FUTUREDEVELOPMENT
BASEMENT PLAN (1:200)
FRONT ARCHITECTS PTY LTD Level 2, 54 Marcus Clarke Street, Canberra City, 2601 P 02 6180 0130 E [email protected]
SCALE
DATE
Plan: Basement 1
PROJECT DRAWING TITLE
DRAWING NO.
PROJECT NO.
DA103
S52 North 'A'SECTION 52 BRADDON, ACT
JWLand Pty Ltd 16-015
REV DESCRIPTION DATE
THIS DRAWING IS COPYRIGHT AND REMAINS THE PROPERTY OF FRONT STUDIO PTY LTD.THIS DRAWING IS FOR DEVELOPMENT APPROVAL AND NOT FOR CONSTRUCTION.
INT'L
FRONT STUDIO Pty Ltd54 Marcus Clarke Street Canberra City ACT 260102 6180 0125 [email protected]
1234567
8
9101112131415
1234567
8
9101112131415
6,10
0
300
3,00
060
03,
000
600
3,00
030
0
5,23
4
6,10
0
7,567
6,10
06,
100
6,40
06,
100
6,10
06,
100
6,10
0
+564,100
1DA300
1DA300
EXIT
ENTRY
EDGE OFSTAGE 4 CARPARK
EDGE OF
STAGE 3 CARPARK
BuildingService Zone
+564.300+567.500
1 16
17 23
24 36
37 50
51 64
65
83
1:5 1:101:10
103
118 CAR PARK PROVISION
BASEMENT 1STAGE 3 = 140 (20 ADAPTABLE)STAGE 4 = 115 (20 ADAPTABLE)
BASEMENT 2STAGE 3 = 150STAGE 4 = 135
BASEMENT 3STAGE 3 = 150STAGE 4 = 135
TOTAL = 825
SMALLCAR
SMALLCAR
SMALLCAR
PARK ABOVE
CU
RR
ON
G S
TR
EE
T
SE
RV
ICE
LA
NE
WA
Y A
BO
VE
CO
OY
ON
G S
TR
EE
T
ELECTRICALSWITCH ROOM
SERVICES
WASTE
1100L
3000L
1100
L
3000L
140
1 15
24
34
47
56
65
74
83
115
84
104
119
98
+567.700
SMALLCAR
SMALLCAR
TANDEM TANDEM
TANDEM TANDEM TANDEM TANDEM TANDEM TANDEM TANDEM TANDEM TANDEM TANDEM TANDEM TANDEM TANDEM TANDEM
SMALLCAR
SMALLCAR
SMALLCAR
SMALLCAR
SMALLCAR
FFL
WASTE
Store Store Store Store Store Store Store Store Store
Store Store Store Store Store Store Store Store Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store Store Store Store Store Store Store Store StoreStore Store StoreStore Store
StoreStoreStoreStoreStoreStoreStoreStoreStoreStoreStoreStore StoreStoreStoreStore
StoreStoreStoreStoreStoreStore
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
Store
StoreStore
StoreStore
StoreStore
StoreStore
StoreStore
StoreStoreStoreStoreStore
Store
Store
Store
Store
Store
Store
Store Store
Store
StoreStoreStore Store Store
Store
Store
2DA300
3DA201
4DA201
1DA200
NA ISSUE FOR COORDINATION 14.03.18V.C
B ISSUE FOR COORDINATION 20.04.18V.C
C ISSUE FOR COORDINATION 30.04.18V.C
3 LEVEL CAR PARKING
TOTAL = 825
GROUND FLOOR PLAN (1:200)
FRONT ARCHITECTS PTY LTD Level 2, 54 Marcus Clarke Street, Canberra City, 2601 P 02 6180 0130 E [email protected]
SCALE
DATE
Plan: Ground
PROJECT DRAWING TITLE
DRAWING NO.
PROJECT NO.
DA104
S52 North 'A'SECTION 52 BRADDON, ACT
JWLand Pty Ltd 16-015
REV DESCRIPTION DATE
THIS DRAWING IS COPYRIGHT AND REMAINS THE PROPERTY OF FRONT STUDIO PTY LTD.THIS DRAWING IS FOR DEVELOPMENT APPROVAL AND NOT FOR CONSTRUCTION.
INT'L
FRONT STUDIO Pty Ltd54 Marcus Clarke Street Canberra City ACT 260102 6180 0125 [email protected]
1234567
8
9101112131415
1234567
8
9101112131415 1
234567
8
9101112131415 1
234567
8
9101112131415
1234567
8
9101112131415
1DA300
1DA300
6,0001,777
4,000
EXIT
ENTRY
ENTRY
RESIDENTIAL &COMMERCIAL
WASTE + SERVICES
CHAMBERSUBSTATION
BASEMENT ENTRYRAMP AS PER S52
SOUTH DESIGN
EXISTINGREGISTERED TREE
EXISTINGREGISTERED TREE
EXISTINGREGISTERED TREE
BRIDGE
BRIDGE
BRIDGE
BRIDGE
LIFT
CU
RR
ON
G S
TR
EE
T
CO
OY
ON
G S
TR
EE
T
BATMAN STREETEXTENSION
SE
RV
ICE
LA
NE
WA
Y
FFL
+568,500
FFL
+568,500
+564.300+567.500
1:51:10
+567.700
LIFT
LIFT
LIFT
2DA300
2DA300
2DA200
3DA201
4DA201
1DA200
NA ISSUE FOR COORDINATION 14.03.18V.CB ISSUE FOR COORDINATION 20.04.18V.CC ISSUE FOR COORDINATION 30.04.18V.CD ISSUE FOR COORDINATION 01.05.18V.C
2 BEDROOM
1 BEDROOM
TYPICAL & 5th FLOOR PLAN (1:200)
TYPICAL FLOOR (LEVEL 1-4) 5TH FLOOR
1234567
8
9101112131415 1
234567
8
9101112131415
1234567
8
9101112131415 1
234567
8
9101112131415 1
234567
8
9101112131415
1234567
8
9101112131415
BRIDGE
BRIDGE
BRIDGE
BRIDGE
L1 +571,500L2 +574,500L3 +577,500L4 +580,500
L1 +571,500L2 +574,500L3 +577,500L4 +580,500
LIFT
LIFT
LIFT
LIFT1234567
8
9101112131415 1
234567
8
9101112131415
1234567
8
9101112131415
1234567
8
9101112131415
1234567
8
9101112131415
1234567
8
9101112131415
1234567
8
9101112131415
1234567
8
9101112131415
1234567
8
9101112131415
1234567
8
9101112131415
1234567
8
9101112131415 1
234567
8
9101112131415 1
234567
8
9101112131415
1234567
8
9101112131415
MECHANICALZONE
ROOF GARDEN
FFL+583,500
FFL+583,500
MECHANICALZONE
LIFT
LIFT
LIFT
LIFT1234567
8
9101112131415 1
234567
8
9101112131415
1234567
8
9101112131415 1
234567
8
9101112131415 1
234567
8
9101112131415
1234567
8
9101112131415
BRIDGE
BRIDGE
BRIDGE
BRIDGE
L1 +571,500L2 +574,500L3 +577,500L4 +580,500
L1 +571,500L2 +574,500L3 +577,500L4 +580,500
LIFT
LIFT
LIFT
LIFT1234567
8
9101112131415 1
234567
8
9101112131415
1234567
8
9101112131415
1234567
8
9101112131415
1234567
8
9101112131415
1234567
8
9101112131415
1234567
8
9101112131415
1234567
8
9101112131415
1234567
8
9101112131415
1234567
8
9101112131415
1234567
8
9101112131415 1
234567
8
9101112131415 1
234567
8
9101112131415
1234567
8
9101112131415
MECHANICALZONE
ROOF GARDEN
FFL+583,500
FFL+583,500
MECHANICALZONE
LIFT
LIFT
LIFT
LIFT
2 BEDROOM
1 BEDROOM
SECTIONS (1:200)
FOUNDERS LANE
ELEVATIONS (1:200)