Page 1: Copyright © 2020. Electro Scan Inc Page 1€¦ · Peter Henley IKT Germany l FELL Used to Accurately Locate CIPP Defects. l FELL Repeatability Tested and Confirmed. l IKT Recommends

Copyright © 2020. Electro Scan Inc Page 1

Page 2: Copyright © 2020. Electro Scan Inc Page 1€¦ · Peter Henley IKT Germany l FELL Used to Accurately Locate CIPP Defects. l FELL Repeatability Tested and Confirmed. l IKT Recommends

IKT Fine-Tunes Pinhole CalculationUK’s WRc UK’s WRc Peter HenleyPeter Henley

IKT Germany l FELL Used to Accurately Locate CIPP Defects. l FELL Repeatability Tested and Confirmed. l IKT Recommends Calculation of Pinhole Leaks. l Electro Scan Develops, Tests, and Releases New Software, March 2019 (See Next Page).

World’s Leading Research Facilities onSewers & Cured-In-Place Pipe (CIPP)

Copyright © 2020. Electro Scan Inc Page 2

Page 3: Copyright © 2020. Electro Scan Inc Page 1€¦ · Peter Henley IKT Germany l FELL Used to Accurately Locate CIPP Defects. l FELL Repeatability Tested and Confirmed. l IKT Recommends

Based on Electro Scan’s Work with IKT, Pinholes Were Separately Identified & Measured for Defect Flow in Gallons Per Minute (GPM) & Liters Per Second (LPS).

CIPP PINHOLESCIPP PINHOLES

FELL Measures CIPP Pinholes

Copyright © 2020. Electro Scan Inc Page 3

Page 4: Copyright © 2020. Electro Scan Inc Page 1€¦ · Peter Henley IKT Germany l FELL Used to Accurately Locate CIPP Defects. l FELL Repeatability Tested and Confirmed. l IKT Recommends

14,450 CIPP Leaks in 20192019 2018

Copyright © 2020. Electro Scan Inc Page 4

Page 5: Copyright © 2020. Electro Scan Inc Page 1€¦ · Peter Henley IKT Germany l FELL Used to Accurately Locate CIPP Defects. l FELL Repeatability Tested and Confirmed. l IKT Recommends

ServiceConnection

Sewer Main

Service Connection

Customer Lateral

FELL has found minimal Infiltration fromCustomer Laterals. Instead, major sources of Infiltration appears to be from inaccurate or poorly assessed Sewer Mains &Service Conections.

Service Connection Assessments

Copyright © 2020. Electro Scan Inc Page 5

Page 6: Copyright © 2020. Electro Scan Inc Page 1€¦ · Peter Henley IKT Germany l FELL Used to Accurately Locate CIPP Defects. l FELL Repeatability Tested and Confirmed. l IKT Recommends

Service Connection Restorations Can Go Wrong & Needs QA/QCHow Sewer Mains LeakHow Sewer Mains LeakMore After CIPP Lining?More After CIPP Lining?

Copyright © 2020. Electro Scan Inc Page 6

Page 7: Copyright © 2020. Electro Scan Inc Page 1€¦ · Peter Henley IKT Germany l FELL Used to Accurately Locate CIPP Defects. l FELL Repeatability Tested and Confirmed. l IKT Recommends

Is Your Consulting Engineer a Certified FELL Data Provider?Is Your Consulting Engineer a Certified FELL Data Provider?

Mapping Your Lateral Connection Defect Heat Map