  • Current and Energy Measurement Technology Efficiency Is That Easy!Product Overview

  • Content

    WAGO Energy Management 4

    Current Transformers Selection Guide 8

    Power and Energy Measurement 10

    Voltage Taps 12

    Plug-In Current Transformers 14with CAGE CLAMP Connection Technology

    Split-Core Current Transformers 18

    Plug-In Current Transformers 20with picoMAX Pluggable Connector

    Line Length Calculation for Current Transformers 22

    Terminal Block Assemblies 24for Current and Voltage Transformers

    High-Current, Rail-Mount Terminal Blocks up to 185 mm2 26

    Current and Voltage Tap 28

    Rogowski Coils 30

    SignalConditionersandIsolationAmplifiers 32

    Intelligent Current Sensors 36

    Measurement Methods 38

    Glossary 40

  • CONVERTING

    Transparency Pays Back

    Complementary electricity and energy measure-ment solutions enable comprehensive consumption recording to create a base for determining relevant efficiencyratios.Itisonlythroughthistransparencythat potential savings can be discovered and, through appropriate measures, considerable cost savingscanberealized.Thisisalsoparticularlyimportant for large-scale consumers, such as the pressorbodyshopinanautoplant.

    WAGO ENERGY MANAGEMENT THE RIGHT SOLUTION FOR EVERY STEPWith Our Modern Energy Data Collection

    Measuring Systematically Record Energy Consumption

    Anywhere high currents must be measured and pro-cessed, plug-in current transformers are always the firstchoice.Ifexistingsystemswillberetrofitted,save time by using Rogowski coils to avoid disas-semblingcablesorinterruptingprocesses.

    4

  • PARAMETER SETTINGVISUALIZING

    Cloud Connectivity(via MQTT)

    EVALUATING

    MEASURING

    Evaluating Identifying and Planning Energy Use

    Three standard operation 3-phase power mea-surement modules within the WAGO-I/O-SYS-TEM750areavailableforrecordingandevaluatingall relevant metrics from a three-phase supply network.Anextremeoperation(XTR)variantisalsoavailableforharshapplications.Thisallowscomprehensive network analysis to be performed and the power supply for machine drives to be optimally controlled, helping prevent damage, machinefailuresanddowntime.

    Parameterization and Visualization

    Software solutions for the WAGO-I/O-SYSTEM and WAGOs signal conditioners make parame-terization and visualization as simple as childs play via the new WAGO Energy Data Management Application.

    Cloud Connectivity

    TheMQTTsoftwareextensionforthePFC100andPFC200Controllersallowsdatatobeeasilytransmittedfromthefieldleveltothecloud.Youcan decide whether the controller sends the data to Microsoft Azure, Amazon Web Services, or IBM Bluemix.

    5

  • WAGO ENERGY MANAGEMENT: ONE SOLUTION MANY APPLICATIONS

    ADVANTAGES: Modular energy and process data collection, management and visualization

    User-friendlyenergydataevaluationandderivationofefficiencyplans Easy input parameterization via Web visualization

    Noprogrammingexperiencerequired Establish indicators to achieve DIN EN ISO 50001

    Economical alternative to energy management software ConnectexistingsensorstotheWAGO-I/O-SYSTEM

    Integratesintoexistingsystemsforflexibilityandmaximumreturnoninvestment

    This user-friendly solution, consisting of software combined with a modular control system, records measurementdatafromdifferentmediaandinfluencingfactorsforenergymonitoringandprocesses them for further analyses, archiving andreporting.

    WiththePFC200ApplicationController(750-8202/000-022),datafrommetersandsen-sors can be easily collected by one convenient input module and parameterized through the avail-able software application no cumbersome and complicatedprogramming.

    Find out more here:www.wago.com/energiemanagement/de

    Easy parameter setting not programming

    6

  • The data can be transferred to higher level energy management software via MODBUS TCP/IPorasaCSVfileviaFTP/FTPS.Inaddition, it is possible to save history on an SDcard.Becauseitissoeasytointegratethe versatile new WAGO solution into existingsystems,adaptingtoindividualrequirementsisalsoquitesimple.Withtheintegrated visualization tool, collected data are readily displayed and evaluated in vari-ousformssuchasbarorlinegraphs.

    PFC200ApplicationController(750-8202/000-022)

    Record virtually all relevant metrics like gas, heat, water, compressed air, temperature and electrical energy in industrial and process technologies or buildingapplications.

    750-820x/ 000-022

    15-minute pulse (power supply)

    S0 counter, pulse counter

    Current and voltage measurement

    Flow,pressure,temperature,etc.

    Computer Database

    WAGO-I/O-SYSTEM750

    ETHERNET

    Poweron/off

    DI

    DI 3-PH M-Bus

    AI EnOcean

    DO

    7

  • CURRENT TRANSFORMERS SELECTION GUIDEThe Right Solution for Every Application

    855 Series Current Transformers Split-Core Current Transformers

    Plug-In Current Transformers with CAGE CLAMP Connection Technology

    Plug-In Current Transformers with a picoMAX Pluggable Connector Rogowski Coils RT500/RT2000

    Rogowski Coils RC 70 / RC 125 / RC 175

    Application Retrofits New systems New systems Retrofits Retrofits

    Coil bobbin Separable Closed Closed Separable Bayonet connector, separable

    Connection technology Connection cable (color coded) CAGE CLAMP picoMAX Connection cable Connection cable

    Mounting Round cable (insulated), copper current bar (insulated)Round cable, copper current bar, DIN-rail, mounting plate

    Round cable, DIN-rail, mounting plate

    Round cable (insulated), copper current bar (insulated)

    Round cable, copper current bar

    Compatibility with other WAGO components

    750-493,(750-493/000-001)750-494,(750-494/000-001)750-495,(750-495/000-001)857-550

    750-493 750-494 750-495 857-550

    750-495/000-002857-552789-652/789-654

    750-495/000-002857-552

    Primary rated current 601000A 502500A 32 A 35 / 64 A Up to 2000 A Upto4000A

    Secondary rated current 1A/5A 1A/5A 320 mA 1 A (upto40.02mV) 22.5mV/kA

    Accuracy class 0.5;1or3 1 or 3 0.5* 1 1

    Ambient operating temperature 10+55C 5+50C 10+55C 40+80C 40+80C

    Standards EN61869-2 EN61869-2 EN61869-2 IEC 61010-1 IEC61010-1/EN61869-2

    Approvals Y Y Y UL pending

    Connection examples

    *Inthemeasurementrange0.8to32AandincombinationwithWAGOs3-phasepowermeasurementmodules, theaccuracyclass0.5ismetperEN61869-2.

    8

  • 855 Series Current Transformers Split-Core Current Transformers

    Plug-In Current Transformers with CAGE CLAMP Connection Technology

    Plug-In Current Transformers with a picoMAX Pluggable Connector Rogowski Coils RT500/RT2000

    Rogowski Coils RC 70 / RC 125 / RC 175

    Application Retrofits New systems New systems Retrofits Retrofits

    Coil bobbin Separable Closed Closed Separable Bayonet connector, separable

    Connection technology Connection cable (color coded) CAGE CLAMP picoMAX Connection cable Connection cable

    Mounting Round cable (insulated), copper current bar (insulated)Round cable, copper current bar, DIN-rail, mounting plate

    Round cable, DIN-rail, mounting plate

    Round cable (insulated), copper current bar (insulated)

    Round cable, copper current bar

    Compatibility with other WAGO components

    750-493,(750-493/000-001)750-494,(750-494/000-001)750-495,(750-495/000-001)857-550

    750-493 750-494 750-495 857-550

    750-495/000-002857-552789-652/789-654

    750-495/000-002857-552

    Primary rated current 601000A 502500A 32 A 35 / 64 A Up to 2000 A Upto4000A

    Secondary rated current 1A/5A 1A/5A 320 mA 1 A (upto40.02mV) 22.5mV/kA

    Accuracy class 0.5;1or3 1 or 3 0.5* 1 1

    Ambient operating temperature 10+55C 5+50C 10+55C 40+80C 40+80C

    Standards EN61869-2 EN61869-2 EN61869-2 IEC 61010-1 IEC61010-1/EN61869-2

    Approvals Y Y Y UL pending

    Connection examples

    *Inthemeasurementrange0.8to32AandincombinationwithWAGOs3-phasepowermeasurementmodules, theaccuracyclass0.5ismetperEN61869-2.

    9

  • POWER AND ENERGY MEASUREMENTWith the WAGO-I/O-SYSTEM 750 and 750 XTR

    Image

    Energy consumption

    Voltage 3~ 480 V 3~ 480 V 3~480V/690V

    Current 1A(750-493) 5A(750-493/000-001)

    1A(750-494) 5A(750-494/000-001)Externalshunts(750-494/000-005)

    1A(750-495) 5A(750-495/000-001) Rogowskicoil(750-495/000-002)

    Active power/energy

    Phase position

    Reactive power/energy via function block

    Apparent power/energy via function block

    Rotary field detection

    Power factor ()

    Frequency measurement

    Four-quadrant operation (inductive, capacitive, consumer, generator)

    Harmonic analysis (up to the 41st harmonic)

    Neutral conductor measurement

    Other product variants

    Extendedtemperaturerange: 20+60C(4...+140F)750-494/025-000(1A), 750-494/025-001(5A)

    750XTR: 750-495/040-000(1A), 750-495/040-001(5A), 750-495/040-002(Rogowskicoil)

    Housing width 12mm(0.472in.) 12mm(0.472in.) 24mm(0.945in.)

    Item number 750-493 750-494 750-495

    ADVANTAGES:

    Measure machine and system energy consump-tion values

    Measures and processes all relevant measured variables

    Comprehensive network analysis ConnectiontotheWAGO-I/O-SYSTEM: fieldbus-independent,compactandflexible

    Thedarkgraymodulesfromthe750XTRSeriescanalsobeusedineXTRemeenviron-mentsandoffertheseadvantages: eXTRemetemperaturesfrom40to+70C (40...+158F) eXTRemeisolationupto5kVof impulse voltage -eXTRemevibrationresistanceupto5g of acceleration

    The I/O modules for three-phase power measure-ment record and process all relevant metrics from athree-phasesupplynetwork.Theyprovidesys-tem operators with increased insight into energy

    consumptionbyspecificmachinesandsystems,as well as the ability to perform comprehensive networkanalysis.

    10

  • 12

    34

    56

    78

    ON

    General Configurations Power, energy and N-conductor measurement of a machine ina480/690VACmainsnetworkviathree-phasepowermea-surementmodule(750-495)

    General ConfigurationsPowerandenergymeasurementofamachineina480VACmains network via three-phase power measurement module (750-493,750-494)

    Machine Machine

    Application Direct connection of Rogowski coils to the three-phase power measurement module(750-495/000-002)

    Loads Current measurement(viaexternalshunts)

    Application Directconnectionofexternalshuntstothe three-phase power measurement module(750-494/000-005)

    IN

    IL3

    IL2

    IL1

    N

    L3

    L2

    L1

    N

    L3L2L1

    L3

    L2

    L1

    NL3L2L1

    L1

    L3

    NL3L2L1

    N

    L3

    L2

    L1

    IN

    IL3

    IL2

    IL1

    N

    L2

    L1L2L3N

    NL3L2L1

    L1

    L2

    L3

    N

    Z1Z1Z1

    11

  • 12

    34

    56

    78

    ON L1

    13 14

    750-495

    L2

    L3

    N

    ABCD

    EFGH

    I1+ I1-

    15 16

    I2+ I2-

    I3+ I3-

    IN+ IN-

    ABCD

    EFGH

    S1S2

    S1S2

    S1S2

    L1L2

    L3N

    PES1

    S2

    VOLTAGE TAPSForInsulatedConductors

    Integrated SIBA fuse to protect equipmentandconductor

    Installation on insulated con-ductor with IDC connection

    ADVANTAGES: Fastermeasurementvoltagetapping

    with just one turn Tool-free assembly Conductor contact via IDC connection Reliable measurement device and conductor

    protection via integrated SIBA fuse

    Terminal Block Assembly, 2007-8874

    Voltage Taps for Insulated Conductors, 855 Series

    Split-Core Current Transformers, 855 Series

    3-Phase Power Measurement Module, 750-495

    Application Example: The Complete Retrofit Solution

    N L3 L2 L1

    N L3 L2 L1

    Image Conductor Range Fuse Cable Length Mounting Item Number

    2.5...6mm2(14...10AWG)3 5 mm FeedthroughforMeasurementConductor

    2A,450V,F,70kA (5x25mm)

    3m (pre-assembled)

    Conductor contact via IDC connection

    855-8001

    855-8002

    10...16mm2(8...6AWG)57mm (feedthrough for measurement conductor)

    2A,450V,F,70kA (5x25mm) 855-8003

    855-8004

    Watch the video tolearnmore.

    12

  • 12

    34

    56

    78

    ON L1

    13 14

    750-495

    L2

    L3

    N

    ABCD

    EFGH

    I1+ I1-

    15 16

    I2+ I2-

    I3+ I3-

    IN+ IN-

    ABCD

    EFGH

    S1S2

    S1S2

    S1S2

    L1L2

    L3N

    PES1

    S2

    VOLTAGE TAPSForBusbars

    Installationonbusbar; fastening with Allen wrench

    Integrated SIBA fuse (overload and short circuit protection)

    Conductor termination via Push-in CAGE CLAMP connection technology

    Various marking options for clearidentification

    ADVANTAGES: Fast,easyinstallationtolivebusbarwithclamp

    mount or M6/M8 mount Variousmarkingoptionsforclearidentification Universal conductor termination via Push-in

    CAGE CLAMP connection technology Fusedvoltagepathprotectsdownstream

    measurement devices

    Image Fuse Connection Technology Solid-/Fine-Stranded Mounting Item Number

    2A,450V,F,70kA (5x25mm)

    Push-in CAGE CLAMP (WAGO 2624 Series)

    M6 mount 855-8006

    M8 mount 855-8008

    Clamp mount (415mm/ 0.157...0.591in. bar thickness)

    855-8015

    Terminal Block Assembly, 2007-8874

    Voltage Taps,855 Series

    Plug-In Current Transformers with CAGE CLAMP, 855 Series

    3-Phase Power Measurement Module, 750-495

    Application Example: The Complete Retrofit Solution

    N L3 L2 L1

    N L3 L2 L1

    13

  • PLUG-IN CURRENT TRANSFORMERS With CAGE CLAMP Connection Technology

    CAGE CLAMP connectionConductor termination

    ADVANTAGES: Screwless CAGE CLAMP connection technology Primarycurrents50to2500A/secondarycurrents1Aor5A Continuous overload of 120% the nominal primary current Tool-freeinstallationviaquick-mountkit Low-voltagecurrenttransformerformax.operatingvoltagesupto1.2kV ULcertified(CertificateNo.E356480) EN61869-1/EN61869-2 Watch the video to

    learnmore.

    14

  • Y

    Quick-MountKit,855-9910 Mounting on round cable

    Mounting on DIN-rail via carrier rail adapter Secured to mounting plate

    Mounting on copper DIN-rail

    Time-Saving Installation with Plug-in Current Transformers from WAGO

    15

  • Accessories Item Number

    Carrier Rail Adapter for Plug-In Current Transformers (for855-3xx/xxxx-xxxxand855-4xx/xxxx-xxxx) 855-9900

    Quick-Mount Kit (2 pieces including cable tie) 855-9910

    Image Primary Rated CurrentSecondary Rated Current Rated Power

    Accuracy Class Item Number

    50 A 1 A 1.25VA 3 855-301/050-103

    50 A 5 A 1.25VA 3 855-305/050-103

    60 A 1 A 1.25VA 1 855-301/060-101

    60 A 5 A 1.25VA 1 855-305/060-101

    75A 1 A 2.5VA 1 855-301/075-201

    75A 5 A 2.5VA 1 855-305/075-201

    100 A 1 A 2.5VA 1 855-301/100-201

    100 A 5 A 2.5VA 1 855-305/100-201

    150 A 1 A 5VA 1 855-301/150-501

    150 A 5 A 5VA 1 855-305/150-501

    200 A 1 A 5VA 1 855-301/200-501

    200 A 5 A 5VA 1 855-305/200-501

    250 A 1 A 5VA 1 855-301/250-501

    250 A 5 A 5VA 1 855-305/250-501

    300 A 5 A 5VA 1 855-305/300-501

    400 A 1 A 10VA 1 855-301/400-1001

    400 A 5 A 10VA 1 855-305/400-1001

    600 A 1 A 10VA 1 855-301/600-1001

    600 A 5 A 10VA 1 855-305/600-1001

    250 A 1 A 5VA 1 855-401/250-501

    250 A 5 A 5VA 1 855-405/250-501

    400 A 1 A 5VA 1 855-401/400-501

    400 A 5 A 5VA 1 855-405/400-501

    600 A 1 A 5VA 1 855-401/600-501

    750A 5 A 5VA 1 855-405/750-501

    Currentbar1:30x10mm Currentbar2:25x12mm Currentbar3:20x20mmRound cable: 26mm

    Busbar1:40x10mmBusbar2:30x15mmRound cable: 32mm

    PLUG-IN CURRENT TRANSFORMERS With CAGE CLAMP Connection Technology

    16

    80.9

    91.1

    5

  • Image Primary Rated CurrentSecondary Rated Current Rated Power Accuracy Class Item Number

    400 A 1 A 10VA 1 855-501/400-1001

    400 A 5 A 10VA 1 855-505/400-1001

    600 A 1 A 10VA 1 855-501/600-1001

    600 A 5 A 10VA 1 855-505/600-1001

    800 A 1 A 10VA 1 855-501/800-1001

    800 A 5 A 10VA 1 855-505/800-1001

    1000 A 1 A 10VA 1 855-501/1000-1001

    1000 A 5 A 10VA 1 855-505/1000-1001

    1500 A 1 A 5VA 1 855-601/1500-501

    1500 A 5 A 5VA 1 855-605/1500-501

    1000 A 1 A 10VA 1 855-801/1000-1001

    2000 A 1 A 10VA 1 855-801/2000-1001

    2000 A 5 A 10VA 1 855-805/2000-1001

    2500 A 1 A 10VA 1 855-1001/2500-1001

    2500 A 5 A 10VA 1 855-1005/2500-1001

    Busbar1:50x12mm Busbar2:40x30mmRound cable: 44mm

    Busbar1:63x10mm Busbar2:50x30mmRound cable: 44mm

    Busbar1:80x10mm Busbar2:60x30mmRound cable: 55mm

    Busbar1:100x10mm Busbar2:80x30mmRound cable: 70 mm

    17

    105.

    2511

    4.85

    134.

    414

    7.45

  • SPLIT-CORE CURRENT TRANSFORMERSRetrofit Existing Systems

    ADVANTAGES: No measuring cable interruption Primarycurrents60to1000A/secondarycurrents1or5A Compact,dividablehousingmeansfastandeasymountingforretrofits Transformerleg(855-5xxx)canbecompletelyremovedifspaceistight Easy,cost-effectiveinstallationviacableties(included) Color-coded connection cables EN61869-1/EN61869-2 Watch the video to

    learnmore.

    Simple termination!

    Quick and easy mounting!

    18

  • Image Primary Rated CurrentSecondary Rated Current Rated Power

    Accuracy Class

    Cable Length Item Number

    18mm

    60 A 1 A 0.2VA 3 3m 855-3001/060-003

    100 A 1 A 0.2VA 3 3m 855-3001/100-003

    200 A 1 A 0.2VA 1 3m 855-3001/200-001

    250 A 1 A 0.2VA 1 3m 855-3001/250-001

    18mm

    100 A 1 A 0.2VA 1 3m 855-4001/100-001

    150 A 1 A 0.2VA 1 3m 855-4001/150-001

    150 A 5 A 1 VA 1 0.5m 855-4005/150-101

    200 A 1 A 0.2VA 0.5 3m 855-4001/200-001

    28mm

    200 A 1 A 0.2VA 1 3m 855-4101/200-001

    250 A 1 A 0.2VA 1 3m 855-4101/250-001

    250 A 5 A 1 VA 1 0.5m 855-4105/250-101

    400 A 1 A 0.2VA 1 3m 855-4101/400-001

    400 A 5 A 1 VA 1 0.5m 855-4105/400-101

    42 mm

    250 A 1 A 0.5VA 1 5m 855-5001/250-001

    400 A 1 A 0.5VA 0.5 5m 855-5001/400-000

    400 A 5 A 0.5VA 1 3m 855-5005/400-001

    600 A 1 A 0.5VA 0.5 5m 855-5001/600-000

    600 A 5 A 0.5VA 0.5 3m 855-5005/600-000

    1000 A 1 A 0.5VA 0.5 5m 855-5001/1000-000

    1000 A 5 A 0.5VA 0.5 3m 855-5005/1000-000

    2 x 42 mm

    1000 A 1 A 0.5VA 0.5 5m 855-5101/1000-000

    1000 A 5 A 0.5VA 0.5 3m 855-5105/1000-000

    19

  • Y

    With 1A Output

    Mounting

    Conductor Termination

    Image Primary Rated CurrentSecondary Rated Current Rated Power

    Accuracy Class

    Conductor Hole Item Number

    35 A 1 A 0.2VA 1 7.5mm 855-2701/035-001

    64 A 1 A 0.2VA 1 7.5mm 855-2701/064-001

    Carrier Rail Adapter 855-9927

    PLUG-IN CURRENT TRANSFORMERSWith picoMAX Pluggable Connector

    ADVANTAGES: Converts 64 A or 35 A to 1 A Accuracyclass1perEN61869-2 Mount on DIN-rail or panels via carrier rail adapter ULcertified(CertificateNo.E356480) Watch the video to

    learnmore.

    Justsnaptogether.

    Push-in termination of solid and ferruled conductors

    UsecarrierrailadaptertosnaptoDIN-rail.

    Universalconnectionforfine-strandedcon-ductors

    As a space-saving option, mount directly abovecircuitbreaker.

    20

  • With Low Power Output

    Mounting

    Conductor Termination

    ADVANTAGES: Firsttransformerwithlowerpoweroutput Specificallydesignedforconvertinglowcurrentsfrom32Ato320mA Complieswithaccuracyclass0.5perEN61869-2inthemeasurementrangeof0.8to32AandincombinationwithWAGOs3-PhasePowerMeasurement Module Watch the video

    tolearnmore.

    Justslidetogether.

    Push-in termination of solid and ferruled conductors

    Side-by-side assembly

    Universalconnectionforfine-strandedcon-ductors

    To save space, mount directly above circuit breaker.

    Image Primary Rated CurrentSecondary Rated Current Rated Power

    Accuracy Class

    Conductor Hole Item Number

    32A* 320 mA 0.1 0.5** 5.0mm(0.197in.) 855-1700/032-000

    *Measurementrange:0.8to32Aincombinationwiththethree-phasepowermeasurementmodules(750-493/494/495)**TestingadherestoEN61869-2withaconversionratioof16A/0.16A(accuracyclass:0.5)andanextendedprimarycurrentof200%

    21

  • LINE LENGTH CALCULATION FOR CURRENT TRANSFORMERS

    WAGOInterfaceConfigurationSoft-ware Start Screen

    Todetermineactualpowerrequirements,boththepowerrequirementsoftheconnectedmea-surement devices and the power losses from the measurement lines connected to a transformers

    iStock.com/AvatarKnowmad

    secondarycircuitmustbetakenintoaccount. Theinterfaceconfigurationsoftwaresnewfeaturequicklyand easily calculates cable length and provides the results foryoursystemdocumentation.

    Refined Solution for Your System Planning

    22

  • Current transformer 5 A

    Currenttransformer1A

    PV= 52x2x10

    1.5x56

    PV= VA=0.24VA12x2x10

    1.5x56

    Note:Whenusingacommonthree-phasereturnline,thevaluesforPVarehalved.

    IS = Secondary rated measuring current strength [A] l = Simple cable length in m ACU =Cablecross-sectioninmm PV = Power loss of connection cables

    Powercalculationofcoppercablesbetweenmeasurementdeviceandcurrenttransformer:

    PV= VAIS2x2xl

    ACUx56

    Example:A 1 amp or 5 amp current transformer is used, with an ammeter on the secondary circuit, at a distanceof10mbetweenthetransformerand

    themeasurementdevice.

    =5.96VA

    Freesoftwaredownloadat:www.wago.com/configuration-software

    CablelengthcalculationusingWAGOInterfaceConfigurationSoftware Simply documented!

    23

  • S1S2

    S1S2

    S1S2

    L1L2

    L3N

    PEL1 IL1

    13 14

    750-493

    L2 IL2

    L3 IL3

    N IN

    ABCD

    EFGH

    S1 S2 S1 S2 S1 S2 L1 L2 L3 N PE S1 S2 S1 S2 S1 S2

    TERMINAL BLOCK ASSEMBLIES FOR CURRENT TRANSFORMERS AND VOLTAGE TAPS

    IL1

    IL2

    IL3

    IN

    L1

    L2

    L3

    N

    PENL3L2L1

    3-Phase Power Measurement Module, 750Series

    Terminal Block Assemblies for Current Transformers and Voltage Taps

    Current Transformers, 855 Series

    Pre-assembled terminal block assembly for easily connecting and short circuiting current transform-ers, suitable for three-phase power measurement modules(750-495and750-494)

    L1

    L2

    L3

    I-S2 k-S1

    Compactterminalblockforcurrenttransformercircuit,2007-8873 Connection option for current and voltage, including Y point jumper

    2007-8875 Connection option for current and voltage, including Y point jumper

    I-S2 k-S1

    I-S2 k-S1

    For Fast and Easy Connections

    24

  • S1S2

    S1S2

    S1S2

    L1L2

    L3N

    PES1

    S2

    L1

    13 14

    750-495

    L2

    L3

    N

    ABCD

    EFGH

    I1+ I1-

    15 16

    I2+ I2-

    I3+ I3-

    IN+ IN-

    ABCD

    EFGH

    I-S2

    S1 S2 S1 S2 S1 S2S1 S2S1 S2 S1 S2 S1 S2 L1 L2 L3 N PES1 S2

    Pre-assembled terminal block assembly for easily connect-ing and short circuiting current transformers, suitable for three-phasepowermeasurementmodules(750-495)

    Compactterminalblockforcurrenttransformercircuit,2007-8874; connection option for current and voltage

    Compact terminal block for current transformer circuit, 2007-8877;connectionoptionforcurrent

    3-Phase Power Measurement Module, 750Series

    Terminal Block Assemblies for Current Trans-formers and Voltage Taps

    Current Transformers, 855 Series

    L1

    L2

    L3

    N

    PENL3L2L1

    k-S2

    N

    IL1IL1IL2IL2IL3IL3

    ININ

    L1

    L2

    L3

    k-S1

    I-S2 k-S1

    I-S2 k-S1

    I-S2

    ADVANTAGES: Neutral bridging Easy and clear wiring Short-circuiting of current transformers Test sockets for control measurements Visible current and voltage path separation

    Watch the video tolearnmore.

    25

  • HIGH-CURRENT, RAIL-MOUNT TERMINAL BLOCKS UP TO 185 mm2 (350 KCMIL)The Ideal Addition to Current Measurement with Plug-In Transformers

    Fast Termination Eliminate time-consuming

    preparation no ring ter-minalsorferrulesrequired

    Always Reliable Perfect clamping force

    independent of operator skill

    Easy Termination Side-entry conductor

    termination Orange locking tab

    keeps the clamp open for hands-free wiring

    Suitable for All Applications Meet the most strin-gentrequirements,including those spec-ifiedforrailwayandmarine applications

    Material durability at highandlowexternaltemperatures

    285 Series Item NumberDesignation 35 mm2 (2 AWG) 50mm2 (1/0AWG) 95mm2 (4/0AWG) 185 mm2 (350 kcmil)

    Conductor range 6 35 mm2

    102AWG1050(70f-st)mm281/0AWG

    25...95mm24 4/0 AWG

    50 185 mm2 1/0 AWG 350 kcmil (groundperstandardmax.120mm2 / 250 kcmil)

    Nominal current IN 125 A 150 A 232 A 353 ARated voltage 1000V 1000V 1000V 1000 VAC/DC, 1500 VDCThrough terminal block 285-135 285-150 285-195 285-1185

    Through terminal block 285-134 285-154 285-194 285-1184

    Ground conductor terminal block 285-137 285-157 285-197 285-1187

    Adjacent jumper* 285-435 285-450 285-495 285-1171

    Step-down jumper (for TOBJOB S, 10/16 mm2) 285-430 - - -

    Power tap* 285-427 285-447 285-407 285-1175Three phase set (without DIN-rail and mark-ing accessories) 285-139 285-159 285-199 285-1169

    Warning cover 285-420 285-440 285-170 285-1177

    Shock protector 285-421 285-441 285-169 285-1178

    Marking strip (reel) 2009-110 2009-110 2009-110 2009-110

    Marker carrier 285-442 285-442 285-442 -

    WMB Inline markers (reel) 2009-115 2009-115 2009-115 2009-115

    WMB Multi marking system (for 5 5.2 mm) 793-5501 793-5501 793-5501 793-5501

    *Formoretechnicaldata,seeourFullLineCatalog,Volume1,orvisithttp://eshop.wago.com.

    26

  • 12

    34

    56

    78

    ON

    S1S2S1S2S1S2L1L2L3NPE

    L1 IL1

    13 14

    L2 IL2

    L3 IL3

    N IN

    ABCD

    EFGH

    open

    open

    open

    open

    open

    open

    HIGH-CURRENT, RAIL-MOUNT TERMINAL BLOCKS UP TO 185 mm2 (350 KCMIL)

    285-407

    285-195

    855-xxx

    The power tap is inserted into the jumper contact slot.Itcanbefittedwithastrainreliefplate(for35mm2 high-current,rail-mountterminalblocks).

    L1 L2 L3

    Power tap provides safe and easy power distribution to additional loads.Thetapisinsertedwhenthespringisretractedwithoutconnected conductor (for 50mm2/1/0 AWG to 185 mm2 /350 kcmil) high-current,rail-mountterminalblocks).

    27

  • CURRENT AND VOLTAGE TAPThe 2-in-1 Solution

    Output Current Energy measurement device connection

    (1A) Short-circuiting the current transformer Neutral bridging

    Marking Possibility TOPJOB S Marking Strips WMB Multi Marking System

    Feedthrough forPrimary Conductors up to 95 mm2/4/0 AWG

    Fuse Protection

    Output Voltage Redundant design

    855-951/250-000

    Technical Data for Current and Voltage Taps (855-951/250-000)

    Primary rated current Ipri 250 A

    Secondary rated current Isec 1 A

    Accuracy class 0.5

    Rated power Sr 0.2VA

    Rated voltage 690VAC

    Fuse 2A,450V,F,70kA(5x25mm)

    Feedthrough for measurement conductor 16.0mm(0.630in.)

    A combination of current transformer and voltage tap, the current and voltage tap (can bequicklyandeasilymountedintothejumperslot of a two-conductor through terminal block

    (95mm/4/0AWG,285-195).Thiscombinationfitsperfectly into a successful energy management plan.

    28

  • 12

    34

    56

    78

    ON

    open

    open

    open

    open

    open

    open

    open

    open

    open

    open

    CURRENT AND VOLTAGE TAP

    ADVANTAGES: Power data can be directly tapped into the power supply Easy installation simply insert the tap into the jumper slot of the two- conductorthroughterminalblock(95mm/4/0AWG)with POWER CAGE CLAMP

    Integrated 250 A/1 A current transformer Complieswithaccuracyclass0.5perEN61869-2forexactmeasurement

    results Fusedvoltagepathprotectsdownstreammeasurementdevices

    Measurement Evaluation Visualization and Configuration

    Power Supply

    Watch the video to learnmore.

    Current and voltage can be measured directly at the supply with the current andvoltagetap(855-951/250-000)and the two-conductor through terminal block (95mm/4/0AWG,285-195)

    29

  • Image Description Cable Length Feedthrough for Measurement Conductor Primary Rated Current* Output Signal Accuracy Class** Item Number

    RogowskicoilsRC-0701.5m(59.06in.)

    70mm(2.756in.) 4000AAC 22.5mV/kAat 50 Hz 1855-9150/2000-0701

    4.5m(0.177in.) 855-9450/2000-0701

    Rogowski coil RC-1251.5m(59.06in.)

    125mm(4.921in.) 4000AAC 22.5mV/kAat 50 Hz 1855-9150/2000-1251

    4.5m(0.177in.) 855-9450/2000-1251

    RogowskicoilRC-1751.5m(59.06in.)

    175mm(6.890in) 4000AAC 22.5mV/kAat 50 Hz 1855-9150/2000-1751

    4.5m(0.177in.) 855-9450/2000-1751

    Rogowski coil RT-5001.5m(59.06in.)

    55mm(2.165in.) 500 AAC 10.5mV/500Aat 50 Hz -855-9100/500-000

    3.0m(118.11in.) 855-9300/500-000

    Rogowski coil RT-20001.5m(59.06in.)

    125mm(4.921in.) 2000AAC 40.2mV/2000Aat 50 Hz -855-9100/2000-000

    3.0m(118.11in.) 855-9300/2000-000

    *ThespecificationsfortheprimaryratedcurrentrefertoacombinationwiththeWAGOModules(857-552and750-495/000-002). Rogowskitechnologyallowsthecoilstomeasureawideprimarycurrentrangeofupto10,000Awithoutlossofaccuracy, becausetherearenosaturationeffectswiththistechnology. **perEN61869-2

    ROGOWSKI COILSFor Quick, Easy Retrofit of Existing Systems

    ADVANTAGES: Ratedinsulationvoltage: 1000VCat.III/600VCat.IV

    Accuracyclass1perEN61869-2 IP67protectionclass Ambienttemperature:40+80C ULcertified Watch the video to

    learnmore.

    30

  • Y

    12

    34

    56

    78

    ON

    L1L2L3N

    Image Description Cable Length Feedthrough for Measurement Conductor Primary Rated Current* Output Signal Accuracy Class** Item Number

    RogowskicoilsRC-0701.5m(59.06in.)

    70mm(2.756in.) 4000AAC 22.5mV/kAat 50 Hz 1855-9150/2000-0701

    4.5m(0.177in.) 855-9450/2000-0701

    Rogowski coil RC-1251.5m(59.06in.)

    125mm(4.921in.) 4000AAC 22.5mV/kAat 50 Hz 1855-9150/2000-1251

    4.5m(0.177in.) 855-9450/2000-1251

    RogowskicoilRC-1751.5m(59.06in.)

    175mm(6.890in) 4000AAC 22.5mV/kAat 50 Hz 1855-9150/2000-1751

    4.5m(0.177in.) 855-9450/2000-1751

    Rogowski coil RT-5001.5m(59.06in.)

    55mm(2.165in.) 500 AAC 10.5mV/500Aat 50 Hz -855-9100/500-000

    3.0m(118.11in.) 855-9300/500-000

    Rogowski coil RT-20001.5m(59.06in.)

    125mm(4.921in.) 2000AAC 40.2mV/2000Aat 50 Hz -855-9100/2000-000

    3.0m(118.11in.) 855-9300/2000-000

    *ThespecificationsfortheprimaryratedcurrentrefertoacombinationwiththeWAGOModules(857-552and750-495/000-002). Rogowskitechnologyallowsthecoilstomeasureawideprimarycurrentrangeofupto10,000Awithoutlossofaccuracy, becausetherearenosaturationeffectswiththistechnology. **perEN61869-2

    Easy to Use: Rogowskicoildiameter: 70,125or175mm

    Lengthofsignalline:1.5mor4.5m Sealable bayonet connector Anchor points for cable ties

    Bayonet connector:Robust and durable

    Anchor points:Quick and easy mounting with cable ties

    Lock-out seal option:Higher security via sealable bayonet lock

    Direct connection of Rogowski coils to the three-phase power measurement module (750-495/000-002)

    31

  • Description Image Circuit Diagram Input

    Cur

    rent

    and

    Vol

    tage

    Sig

    nal C

    ondi

    tione

    rs

    Current and Voltage Signal Conditioners

    Through-Hole Current Signal Conditioner

    1.11.21.3

    2.2

    1211

    3.13.2

    RELAY

    INPUT CURRENT (AC/DC)

    OUTPUT

    JUMPERPOWER

    POWER

    OUT+OUT

    4.14.2

    4.3

    6.16.2

    Us+GND

    Us+GND

    14

    4.4DO (GND) DO

    JUMPERDO

    DOGND

    AC/DC 100 A

    Current Signal ConditionerOUTIN

    POWER

    5

    6

    1

    2

    3

    4

    7

    8

    OUT+

    GND 2

    Us+

    GND 3

    IN 1A (GND 1)

    IN 5A (GND 1)

    DO (GND 3)

    GND 1

    DO

    1AAC/DC5AAC/DC

    Rogowski Coil Current Signal Conditioner

    OUTIN

    POWER

    5

    6

    1

    2

    4

    7

    8

    OUT+

    GND 2

    Us+

    GND 3

    RC1+ (GND 1)

    RC2+ (GND 1)

    DO (GND 3)

    GND 1

    DO

    3

    Rogowski coils500 AAC2000AAC4000AAC

    Voltage Signal Conditioner 300 VAC/DC

    Power Signal Conditioner 300 VAC/DC (5 A)

    Millivolt Signal Conditioner 0200mV0...1000mV 100mV

    Output Output Special Functions Configuration Power Supply Item Number

    010mA210mA020mA4 20 mA

    0 5 V 15V0 10 V 2 10 V

    10mA20 mA5 V10V

    x x x x x x x x 24VDC 2857-550

    010mA210mA020mA4 20 mA

    0 5 V 15V0 10 V 2 10 V

    x x x x x 24VDC 857-550

    010mA210mA020mA4 20 mA

    0 5 V 15V0 10 V 2 10 V

    x x x x x 24VDC 857-552

    010mA210mA020mA4 20 mA

    0 5 V 15V0 10 V 2 10 V

    x x x x x 24VDC 857-560

    010mA210mA020mA4 20 mA

    0 5 V 15V0 10 V 2 10 V

    x x x x x 24VDC 857-569

    010mA210mA020mA4 20 mA

    0 5 V 15V0 10 V 2 10 V

    x x x x 24VDC 857-819

    SIGNAL CONDITIONERS AND ISOLATION AMPLIFIERSCurrent and Voltage Signal Conditioners

    OUTU,I

    INmV

    POWER

    5

    6

    1

    2

    3

    4

    7

    8

    OUT+

    GND 1

    Us+

    GND 2

    IN+

    IN

    N.C.

    N.C.

    Current

    Voltage

    Bipolar signals Current and voltage

    Digital output (DO)

    Clipping capability

    Zero/span adjustment

    32

  • Output Output Special Functions Configuration Power Supply Item Number

    010mA210mA020mA4 20 mA

    0 5 V 15V0 10 V 2 10 V

    10mA20 mA5 V10V

    x x x x x x x x 24VDC 2857-550

    010mA210mA020mA4 20 mA

    0 5 V 15V0 10 V 2 10 V

    x x x x x 24VDC 857-550

    010mA210mA020mA4 20 mA

    0 5 V 15V0 10 V 2 10 V

    x x x x x 24VDC 857-552

    010mA210mA020mA4 20 mA

    0 5 V 15V0 10 V 2 10 V

    x x x x x 24VDC 857-560

    010mA210mA020mA4 20 mA

    0 5 V 15V0 10 V 2 10 V

    x x x x x 24VDC 857-569

    010mA210mA020mA4 20 mA

    0 5 V 15V0 10 V 2 10 V

    x x x x 24VDC 857-819

    SIGNAL CONDITIONERS AND ISOLATION AMPLIFIERS

    Simulation

    DIP switch

    Interface configurationsoftware

    Interfaceconfigurationapp

    Interfaceconfigurationdisplay,2857-900Supply voltage

    Freedownloadfrom Google Play Store

    Freedown-load

    33

  • CD

    B

    A

    CD

    B

    A

    C

    DB

    A

    C

    DB

    A

    CD

    B

    A

    CD

    B

    A

    C

    DB

    A

    C

    DB

    A

    Signal Conditioners and Isolation AmplifiersCurrent and Voltage Signal Conditioners

    PLC

    L1 NPower Signal Conditioner, 857-569

    1-phase power measurement

    Voltage Signal Conditioner, 857-560

    Voltage measurement

    PLC

    L1 N

    Power supply

    Power supply

    34

  • CD

    B

    A

    CD

    B

    A

    C

    DB

    A

    C

    DB

    A

    CD

    B

    A

    CD

    B

    A

    C

    DB

    A

    C

    DB

    A

    CD

    B

    A

    CD

    B

    A

    C

    DB

    A

    C

    DB

    A

    CD

    B

    A

    CD

    B

    A

    C

    DB

    A

    C

    DB

    A

    020mA

    Power supply

    DO/Alarm indication24 V/100 mA

    Current transformer250 A/1 A PLC

    L1

    020mA

    Power supply

    DO/Alarm indication24 V/100 mA

    PLC

    L1

    Rogowski coil

    RT 500 (500 A)+US

    -US

    020mA

    Power supply

    PLC

    DO/Alarm indication24 V/100 mA

    L1

    Power supplyEmergency power

    Current Signal Conditioner, 857-550

    Current measurement via plug-in current transformer

    Current Signal Conditioner, 2857-550

    Light monitoring

    Rogowski Signal Conditioner, 857-552

    Current measurement via Rogowski coil

    35

  • INTELLIGENT CURRENT SENSORSMonitor Solar Plants via MODBUS Communication

    Status indicatorAddressing

    elxeneize/Fotolia.com

    ADVANTAGES: Wide measurement range for measuring AC and DC current Measure line and sum currents for perfect system monitoring Easily guide live conductor through current sensor Quickly mount to DIN-rail

    36

  • Measurement range 0 80 ADC 0140ADC AC 0 50 A rmsTransmission error 0.5%ofupper-rangevalue 0.5%ofupper-rangevalue 0.5%ofupper-rangevalue

    Power supply 12 34 V (via RJ-45) 12 34 V (via RJ-45) 12 34 V (via RJ-45)

    Feedthrough 15 mm (for electrical lines) 15 mm (for electrical lines) 15 mm (for electrical lines)

    Interface RS-485 RS-485 RS-485

    Protocol MODBUS over serial line MODBUS over serial line MODBUS over serial line

    Addressing 1 32 1 32 1 32

    Max. bus length 1200m 1200m 1200m

    Item number 789-620 789-621 789-622

    1 32 sensors

    289-965 RJ-45 Interface Module for Current Sensor Modules

    E.g.,787-1002 EPSITRON COMPACT Power

    Connection to a PERSPECTO Control Panel

    Power supply

    RS-485 serial interface

    37

  • I

    I

    AB

    MEASUREMENT METHODS

    Shunt Measurement (AC/DC)Current measurement is performed using a low-ohm resistor (shunt), which is connected in parallel toavoltmeter.Thecurrentisproportionaltothecurrentmeasuredattheshuntresistor,I=U/R.

    The shunt can be located upstream or down-streamoftheload(high-side/low-sidemethod).WAGOproductsareequippedforbothmethods,giving users the freedom to decide where the con-ductorsectionshouldbedisconnected.Inadditionto DC and AC currents, shunt measurements are also suitable for measuring superimposed signals (DC+AC).Accuraciesof0.1%andgreatercanbeachieved.WAGOs855SeriesPlug-InCurrentTransformerswithapredefineddivisionratiocanbeusedtoexpandthemeasurementrangeforpureACmeasurements.

    Shunt Measurement in Combination with Plug-In Current Transformer (AC)Plug-In Current Transformers are used at higher measurementcurrents.Theyfunctionbasedonthetransformerprincipleandexpandtherangeofanexistingmeasurementsystem(usuallyashunttransformer).Thenumberofsecondarywindingsmirrorsthefixedsettingofthedivisionratio.TheelectricallyisolatedoutputACispropor-tionalandinphasewiththeinputAC.Themeasur-ingerrortypicallyliesbelow1%.

    Iin= Ushunt / Rshunt

    Measuring device

    V

    Rmeas

    Rshunt

    Ushunt

    Uin

    Iin

    Transformer Principle

    Low-Side Method

    High-Side Method

    Iin= Ushunt / Rshunt

    Measuring device

    V

    Rmeas

    Rshunt

    Ushunt

    Uin

    Iin

    38

  • U, I

    U

    Measurement Method Advantages Application Areas

    Shunt Very high accuracy Suitable for DC and AC currents Integration into control and regulation systems Process and energy technology

    Shunt + Current transformer

    Suitable for higher AC currents Potential-free measurement

    Installations and systems technology Network monitoring and analysis

    Hall effect Potential-free measurementForhighercurrents DC and AC versions

    PV systems and general energy technology Control processing of several individual systems

    Rogowski Coil (AC)Aclosed-aircoil,i.e.,coilwithoutironcore,isap-pliedaroundtheconductorthatwillbemeasured.TheACcurrentflowingthroughtheconductorinduces a proportional voltage in the Rogowski coil.Theoutputvoltageisamplifiedandcondi-tioned.Ameasurementerroroflessthan2%andaresponse threshold of only a few amps guarantee straightforward measurement of high to very high ACcurrents.

    Hall Effect Sensors (AC/DC)A soft, magnetic core is wrapped around the conductor.ThecorehasasmallairgapinwhichtheHalleffectsensorislocated.Amagneticfluxisgenerated in the ring-shaped core by the current flowingthroughtheconductor.ThemagneticfluxalsoflowsthroughtheHalleffectsensor,whichoutputs a voltage signal proportional to the current measured.Thissignalispreparedandforwardedforprocessing.UsingtheHallmethod,differentsignals (AC/DC) and measurement ranges can be mapped,dependingonthedesign.Measurementaccuracyliesbetween0.5%and1%.

    I meas

    Uout

    HallEffectSensor

    HallEffectSensorRogowski Coil

    39

  • S

    U

    I

    +

    -

    + +

    --

    SU

    I

    SU

    I++

    -- -

    Apparent Power SApparent power (S) is the total power of a trans-missionnetwork.Itiscomposedofactivepower(P)andreactivepower(Q).Positiveapparentpower,which is in the interest of the consumer, means thatthepowerisdrawnfromthegrid.Negativeapparent power, however, means that power is fed backintothegrid.

    Q=UL*IL

    Active Power PThe active power (P) is the power actually con-sumed.Ithasnophaseshiftbetweencurrentandvoltageandrelatestoaresistiveload.Foranalternating voltage, the active power results from the multiplication of the RMS values for current andvoltage.

    Reactive Power QReactive power (Q) refers to a load on the power grid,whichactsagainstthepowerflowingfromtheproducertotheconsumer.Reactivepoweristheproductofvoltageandcurrentflowingthroughareactance.ReactivepowerisgeneratedbyanydevicethatisconnectedtoanACgrid.Allelectri-calequipmentgeneratesanelectromagneticfieldwhenvoltageisapplied.Themagneticfieldiscon-stantly being built up and then dismantled by the alternatingvoltage.Theenergycreatedwhenthefieldisbeingdismantledisfedbackintothepowergrid,increasingtheresistancetothecurrentflow.

    P=UR*IR

    S=V*I

    GLOSSARY

    40

  • HarmonicsHarmonicsarecurrentshavingfrequenciesthataremultiplesofthe50Hzfundamentalfrequency.Theharmonicdegreeisdefinedastherelationshipbetweenharmonicandfundamentalfrequency.Harmonics are created by devices with non-linear characteristiccurves(e.g.,transformers,rectifiers,televisions,computers,halogenlighting).Thenon-sinusoidal currents of these devices result in a voltage drop in the network impedance, which distortsthenetworknominalvoltageandaffectsoperation.Theimpactsofharmonicscontaminationinclude:failure of protective devices, thermal overload andprematureagingofelectricalequipment,loss of mechanical stability, performance loss, measurement errors, higher noise level, hard drive failures, system crashes, operational breakdowns andmore.

    If many devices are operated within a network that generates the third harmonic, it may result in averyhighcurrentloadoftheneutralconductor.Neutral conductor currents caused by harmonics in TN-C power networks travel within the entire equipotentialbondingsystemviawater/heatingpipes, grounding systems, shields of data lines, videolinesandcommunicationsystems.Thiscanlead to increased corrosion or pitting on piping systems.Therefore, continuous harmonics and neutral conductoranalysisarerequiredforguaranteeingboth power supply and overvoltage protection, as wellasfiresafety.

    Fundamentalfrequency(50Hz)

    Third harmonic (150 Hz)

    Additioncreatesanon-sinusoidalwaveform.

    41

  • 400300200100

    0-100-200-300-400

    1/2T 3/2T 2T

    400350300250200150100

    500

    1/2T T 3/2T 2T

    Irms x21nn

    i=1i

    Sine current

    Sine Arithmetic mean valuePeriod

    PeriodAbsolute value of the sine curve

    RMS

    A

    Meansquarecurrent

    A

    Mean Square ValueThemeansquarevalueRMS(root-mean-square),alsotheTRMS(trueroot-mean-square)isthesquarerootofthequotientofthesumofsquaresfor the measured values and number of measured values(squarerootoftheaverageofthemeasuredvalue).

    Inelectricalengineering,theeffectivevalueofaperiodicquantitycorrespondstotheeffectivevalueoftheDCvariable.Itischaracteristicofthepowertransformedintheconsumer.

    TheRMSandTRMStermsarefrequentlydifferen-tiated.Thisisbasedonhistoricalcontext,sothatnewer measuring procedures are preferred over formfactorbasedmethods.Inprinciple,WAGOmeasuresaccordingtotheTRMSmethod.However,nospecialdifferentiationismade,asbothtermsdescribethesamemathematicalequation,andonemerelyindicatesthespecificaccuracyofthemeasurement.

    Arithmetic Mean ValueThe arithmetic mean value (also average) is the sum of all measured values detected and divided bythenumberofmeasuredvalues.

    Forperiodicvariables(e.g.,sinewaves),thearithmeticmeaniszero.Forthisreason,itisnotmeaningful for use with periodic variables, or it only provides information about a possibly present constant.ForDCvariables,thearithmeticmeanvalue corresponds to the average measured value viewedovertime.

    GLOSSARY

    42

  • 400300200100

    0-100-200-300-400

    8000070000600005000040000300002000010000

    0

    1/2T

    Sampled signal

    Sampling

    Input signal

    Digital ProcessingDuring digital processing, the signal is sampled in defined,veryshorttimeintervals(digitized).Thesampledvaluesareprocessedand,e.g.,convertedintoananalogstandardsignal.

    Digital processes are becoming increasingly common, since high reproducibility and signal-au-thentic mapping can be guaranteed due to high samplingrates.Inaddition,furtherprocessingortransmission of the digitized information is easier, lesssusceptibletointerferenceandmoreflexible,duetothesoftware.

    Analog ProcessingDuring analog processing, the input signal is fed directly to a processing unit and prepared accord-ingtoafixedtransferfunction.Theprocessingoccursusinganoperationalamplifier(OpAmp)andafewpassivecomponents.

    43

  • 0888

    -059

    9/02

    05-6

    901

    C

    URRE

    NT

    AND

    EN

    ERGY

    MEA

    SURE

    MEN

    T TE

    CH

    NO

    LOGY

    BRO

    CH

    URE

    2.5

    US

    10/

    2017

    P

    rinte

    d in

    Ger

    man

    y

    Subj

    ect t

    o de

    sign

    cha

    nges

    WAGO Kontakttechnik GmbH & Co. KGPostfach 2880 32385 [email protected]

    Headquarters +49571/887-0Sales +49571/887-222Orders +49571/887-44333Fax: +49571/887-844169

    WAGOisaregisteredtrademarkofWAGOVerwaltungsgesellschaftmbH.CopyrightWAGOKontakttechnikGmbH&Co.KGAllrightsreserved.ThecontentandstructureoftheWAGOwebsites,catalogs,videosandotherWAGOmediaaresubjecttocopy-right.Distributionormodificationtothecontentsofthesepagesandvideosisprohibited.Furthermore,thecontentmayneitherbecopiednormadeavailabletothirdpartiesforcommer-cialpurposes.AlsosubjecttocopyrightaretheimagesandvideosthatweremadeavailabletoWAGOKontakttechnikGmbH&Co.KGbythirdparties.