department of environmental qualitydeq.wyoming.gov/media/attachments/water quality...pdf to cheyenne...

200
Department of Environmental Quality To protect, conserve and enhance the quality of Wyoming's environment for the benefit of current and future generations. Matt Mead,. Governor April 12,2013 Eugene Ninnie Town of Pinedale P.O. Box 709 Pinedale, WY82941 NOTIFICATION OF COVERAGE Todd Parfitt, Director RE: Pinedale Ball Fields - Water Main Extensions - Permit Number 13-101, E 'Y.SW % Section 34, T34N, R109W, Sublette County Dear Mr. Ninnie: The above application for coverage under General Permit to Construct for the extension of a Public Water Supply System consisting of about 50 linear feet (LF) of 6-inch ductile iron water main, 204 LF of 4-inch PVC water main, 232 LF of 6-inch PVC drain line and a 6-inch reduced pressure zone backflow preventer with vault to serve irrigation systems for soccer and little league fields in accordance with Chapter 3, Section 7 and Chapter 12, Section 14 of the Wyoming Water Quality Rules and Regulations has been reviewed and is hereby approved. You are authorized to construct, the facility in accordance with the general permit and the materials submitted in your application package. Your attention is directed to the mandatory reporting requirements outlined in Part V, Section 0 of the General Permit. These General Permit requirements can be downloaded from the Wyoming Department of Environmental Quality webpage. The General Permits can be found under the Water Quality Division Water and Wastewater Program, Engineering and Technical Servlces.at: http://deq.state.wv.us/wgd/wwwIPermittingIPages/general permits.asp . If you have any questions, please contact me at 307-332-3144. Sincerely, Mark Baron, P.E. Southwest District Engineer Water Quality Division PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941 Page 1 of 1 I.ander Field Office· 510 Meadowview Drive • Lander, WY 82520 • http://deq.state.wy.us ABANDONED MINES (307) 332-5065 FAX 332·1726 AIR QUALITY (307) 332-6755 FAX 332·7726 LAND QUALITY (307\332-3047 l'AX 332·7726 SOLID & HAZARDOUS WASTE. (307) 332-69?A FAX 332·7726 WATER QUALITY (307) 332-3144 FAX 332·7726

Upload: others

Post on 13-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality

To protect, conserve and enhance the quality of Wyoming's environment for the benefit of current and future generations.

Matt Mead,. Governor

April 12,2013

Eugene Ninnie Town of Pinedale P.O. Box 709 Pinedale, WY82941

NOTIFICATION OF COVERAGE

Todd Parfitt, Director

RE: Pinedale Ball Fields - Water Main Extensions - Permit Number 13-101, E 'Y.SW % Section 34, T34N, R109W, Sublette County

Dear Mr. Ninnie:

The above application for coverage under General Permit to Construct for the extension of a Public Water Supply System consisting of about 50 linear feet (LF) of 6-inch ductile iron water main, 204 LF of 4-inch PVC water main, 232 LF of 6-inch PVC drain line and a 6-inch reduced pressure zone backflow preventer with vault to serve irrigation systems for soccer and little league fields in accordance with Chapter 3, Section 7 and Chapter 12, Section 14 of the Wyoming Water Quality Rules and Regulations has been reviewed and is hereby approved. You are authorized to construct, the facility in accordance with the general permit and the materials submitted in your application package. Your attention is directed to the mandatory reporting requirements outlined in Part V, Section 0 of the General Permit. These General Permit requirements can be downloaded from the Wyoming Department of Environmental Quality webpage. The General Permits can be found under the Water Quality Division Water and Wastewater Program, Engineering and Technical Servlces.at:

http://deq.state.wv.us/wgd/wwwIPermittingIPages/general permits.asp .

If you have any questions, please contact me at 307-332-3144. Sincerely,

Mark Baron, P.E. Southwest District Engineer Water Quality Division

PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Page 1 of 1

I.ander Field Office· 510 Meadowview Drive • Lander, WY 82520 • http://deq.state.wy.us ABANDONED MINES

(307) 332-5065 FAX 332·1726

AIR QUALITY (307) 332-6755 FAX 332·7726

LAND QUALITY (307\332-3047 l'AX 332·7726

SOLID & HAZARDOUS WASTE. (307) 332-69?A FAX 332·7726

WATER QUALITY (307) 332-3144 FAX 332·7726

Page 2: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(

(J

Page 3: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality

Matt Mead} Governor

March 21,2013

To protect, conserve and enhance the quality of Wyoming's environment for the benefit of current and future generations.

NOTIFICATION OF COVERAGE

Dassie OVerfield, Manager Northwest Rural Water District (NWRWD) P.O. Box 2347 Cody, WY 82414

RE: NWRWD - Grant Extension - Lovell Service Area DEQ Permit #13-102 Located In Big Ham county; E112, S27, T46N, R96W; Lat44.8064, Long. -108.3934

Dear Ms. Overfield,

Todd P.rfitt, DIC"ctor

This project consists of the installation of approximately 2,998 linear feet of 3 Inch waterline and 1,297 linear feet of 2 Inch waterline along Road 11, South of Lovell, to serve eight new service taps.

The above application for coverage under General permit has been reviewed In accordance with Chapter 3, Section 7; and Chapter 12 of the Wyoming Water Quality Rules and Regulations and is hereby approved.

You are authori..:ed to construct, the facility in accordance with. the the materials submitted in your application package and the General Permit to Construct, Install, Modify' or Operate Extensions to or Modification to Existing Public Water Supply Dislr1bution Systems. Construction shall be completed by October 31, 2015

Your attention is directed to the attached Certificate of Completion form, which is to be submitted within 60 llilY.s of the completion of the aforementioned prolli.ct

These General Permit requirements can be downloaded from the Wyoming Department of Environmental Quality webpage. The General Permits can be found under the Water Quality Division Water and Wastewater Program, Engineering and Technical Services at:

hltp:llde~.state.wv.us/wgd/www/PermittingIPages/general permlts.asg

If you have any questions, pleas!) contact Hannes Stueckl!)r at 307-335-6964 or James Brough at 307-335-6961.

Sincer"'fl / -----?~ ~- ~--.~

Ha as E. Stueckler, PE- _ Assistant Northwest District Engineer Water Quality Division

xc: PDF to Cheyenne Cody A.·Schatz, Engineering Associates, P.O. Box 1900, Cody, WY 82414

Lander Field Office • 510 Meadowview Drive • Lander, WY 82520 • http://deq.state.wy.us ABANDONED MINES

(3071 332-5086 FAX 332-7726

AIR QUALITY (307) 332-6755 FAX 332-7726

LAND QUALITY (307)332-3047 FAX 332·7726

SOLID & HAZARDOUS WAsiE (307) 332-6924 FAX 332-7726

WATER QUALITY (307) 332·3144 FAX 332-7726

Page 4: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

('

(

(j

Page 5: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality

Matthew H. Mead, Governor

April 4, 2013

To protect, conserve and enhance the quality oj Wyoming 's environmentjor the benefit of current and fieture generations.

NOTIFICATION OF COVERAGE

Town of Fort Laramie Attn: Alexander Jankewicz, Mayor 319 North Laramie Avenue Fort Laramie, Wyoming 82212

RE: Sanitary Sewer Outfall Application No. 13-103, Goshen County

Dear Mr. Jankewicz:

Todd Parfitt, Db'ector

The above application for coverage under General Permit to Construct, Install, ModifY or Operate Extensions to or Modifications of Existing Public Sewage Collection Systems consisting of replacing and installing approximately 3,150 lineal feet of 12-inch sewer main and approximately 250 lineal feet of 8·inch sewer main with appurtenances located in the Southwest 'l.I, Section 23, T26N, R64W and Northwest 'l.I, Section 26, T26N, R64W, Goshen County, in accordance with Chapter 3, Section 9 of the Wyoming Water Quality Rules and Regulations has been reviewed and is hereby approved. You are authorized to construct, install or modify the water distribution system in accordance with Chapter 11, Section 9 of the Water Quality Division Rules and Regulations, in accordance with the general permit, the conditions listed below, and the materials submitted in your application package. Your attention is directed to the mandatory reporting requirements outlined in Part V, Section 0 oIllie general permit. Additionally, the following project specific conditions also apply:

1. The variance on the pipe slopes has been granted in accordance with DEQ Policy 13.9.13 for Very Low Slope Sewer Variance.

All construction, installation, or modification allowed by this Notification of Coverage shall be completed by April 4, 2018 .

• , • t < ~.~~.~"~~~ ______________ ~=~=-=", ... ,. ".,' Herschl .. Building· 12Z·W .. t2SthStfe<t . Cbeyenne, WY 82002 • bttp:lldeq.stat •• wy.us .•..... : .'.'~'.' .. ' , ... "!

ADMlN/OUTREA<:U ABAN])ONEDMINES AlRQlIALITY moUS'l'RIALSn'ING LAI'iDQUALfrv S01..ID& HAZ. WASTE' WATER QUALITY (3D?} 771wnss (31)7) 711-6145 (307) 777-1391 (307)'/11-1369 ('JfJ7) 77"1-7755 l?07)717-1752 (301) 7'r/-1'181 FAX 177-7682 FAX77H~('j2 F.AX:717-S616 JIAX117-5973 FAX7TI-s&64 FAX777·5973 FAX 711·59'13

Page 6: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

TIlis Notice of Coverage. is covered under the General Permits on the Wyoming Department of Environmental Quality webpage. The General pennits can be viewed at the following path:

http://deq.state.wy.l1s/Wgd/www/Permitting/Pages/general permits.asp

Please reference Application No. 13-103 in any future correspondence.

If you have any questions, please contact me at either [email protected] or by phone at (307) 777-7088.

Sincerely,

~;)~? SethTourney,P.E. Southeast District Engineer Water Quality Division

SWT/rml13-0313

Enclosures: Certificate of Completion form

cc: IPS Timothy Eisenhauer, Baker & Associates, 1401 East 'M' Street, Torrington, WY, 82240

(

(. , :

(

Page 7: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

I ,

Matthew H. Mead, Governor

April 4, 2013

Department of Environmental Quality To protect, conserve and enhance the quality of Wyoming '$

environment for the benefit of current and foture generations.

NOTIFICATION OF COVERAGE

Cheyenne Board of Public Utilities Attn: Jeffrey Pecenka, Supervising Staff Engineer P.O. Box 1469 Cheyenne, Wyoming 82003

RE: Cheyenne BOPU Five Year Fire Hydrant, Fire Service Line and Service Line Permit Application No. 13.104, Laramie Couuty

Dear Mr. Pecenlca:

Todd Pnrfitl, Director

The above application for coverage under "General Permit to ConstnlCt, Install, ModifY or Operate Extensions to or Modifications of Existing Public Water Supply Distdbution Systems consisting of replacing miscellaneous fire h:Y.drants located witbin the service area for the Cheyenne Board of Public Utilities, LlIramie County, in accordance with Chapter 3, Section 9 of the Wyoming Water Quality Rules and Regulations has been reviewed" and is hereby approved. You are authorized to construct, install or modifY the water distribution system in accordance with Chapter 12, Section 14 of the Water Quality Division Rules and Regulaticrns, in accordance with tbe general permit, the conditions listed below, and the materials submitted in your application package. Your attention is directed to the mandatolY reporting requirements outlined in Part V, Section 0 ofthe general permit. Additionally, !be following project specific conditions also apply:

1. On December 1" of each year during the duration of this permit, tbe applicant shall submit report of all fire hydrants replaced under this permit. This report shall include location, static pressure, residual pressure, and available fire flow for each hydrant installed.

2. Under this permit, all fire hydrants must be installed on 6-inoh or greater water mains. Any ftfe hydrants installed all water mains less than 6-inehs must be hydraulicaUy justified and approved by Seth Tourney, Southeast Engineer for Department of Environmental Quality I Water Quality Division, prior to installation.

All constJ1lCtion, instaJiation, Or modifioation allowed by this Notificatioll of Coverage shall be completed by April 11, 2018.

This Notice of Coverage is covered under !be Gelleral Permits on the Wyoming Department of Environmental Quality webpage. The Gelleral permits can be viewed at the following patb:

http://deq.state.wy.us/wgd/www/PeJ'mitting/Pages/general permits.asp

" .~~~----------=="',! Herscblo, Building· 122 West25th:st1'.1lI"·"C~eyc.ne, WY 82002 . http://de~.'tat··WY·W\l~'''"''QUAJ"n'Y ("I"" ":w',~;Y"".""

,ADMlN/O{ITREACH ABANDONED MINES AlRQUALITY lNDustRJAI,srrING LANDQUAl.JTY SOLID&JJAZ.WASTE A. lit •

(3~1) 777-n'JS (307) 7"/1·6)45 (307)171-7391 (307) 771·n6~ (307)771-7756 (301) 717-7752 (301pn-1781 FKX717-7632 \?AX 777-6462 FAXTI1·Stllli JlAX'm·5913 FAX 777-5864 FAX 717·S!)73 FAX 'J'{'/·'SfY13

Page 8: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

r ., ..

Please reference Application No. 13-104 in any future correspondence.

If you have any questions, please contact me at either [email protected]'byphone at (307) 777-7088.

Sincerely,

./8.~7~~_ Seth Tourney, P.E. Southeast District Engineer Water Quality Division

SWTltml13-0315

Enclosures: Certificate of Completion form

cc: IPS

(

(

(;

Page 9: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

WYOMING DEPARTMENT OF ENVIRONMENTAL QUALITY WATER QUALITY DIVISION PERMIT TO CONSTRUCT

I PERMITNO.13-105

PRAIRIE WIND ELEMENTARY SCHOOL WELL 2

This permit hereby authorizes the applicant:

WYOMING OFFICE OF STATE LANDS AND INVESTMENTS 122 W 25th Street - 3W Cheyenne, WY, 82002

to construct, install or modify one test well for conversion to one municipal water according to the procedures and conditions of the application number 13-105. The facility is located in NE 1/4 of the SE 1/4 of Section 36, T15N, R67W; Laramie County, in the State of Wyoming. All construction, installation, or modification allowed by this permit shall be completed April 10, 2016.

The issuance of this permit confirms that the Wyoming Department of Environmental Quality (DEQ) has evaluated the application submitted by the permittee and determined that it meets minimum applicable construction and design standards. The compliance with construction standards and the operation and maintenance of the facility to meet the engineer's design are the responsibility of the permittee, owner, and operator.

Granting this permit does not imply that DEQ guarantees or ensures that the permitted facility, when constructed, will meet applicable discharge permit conditions or other effluent or operational requirements. Compliance with discharge standards remains the responsibility of the permittee.

Nothing in this permit constitutes an endorsement by DEQ of the construction or the design of the facility described herein. This permit verifies only that the submitted application meets the design and construction standards imposed by Wyoming statutes, rules and regulations. The DEQ assumes no liability for, and does not in any way guarantee or warrant the performance or operation of the permitted facility. The permittee, owner and operator are solely responsible for any liability arising from the construction or operation of the permitted facility. By issuing this permit, the State of Wyoming does not waive its sovereign immunity.

The permittee shall allow authorized representatives from DEQ to enter and inspect.any property, premise or place on or at which the facility is located or is being constructed or installed for the purpose of . investigating actual or potential sources of water pollution, and for determining'dompliEince or:non-" compliance with any rules, regulations, standards, permits or orders.

Nothing in this permit shall be construed to preclude the institution of any legal action or other proceeding to enforce any applicable provision of law or rules and regulations. It is the duty of the permittee, owner and operator to comply with all applicable federal, state and local laws or regulations in the exercise of its activities authorized by this permit.

The issuance of this permit does not convey any property rights in either real or personal property or any invasion of personal rights, nor any infringement of federal, state or local laws or regulations.

The permittee shall construct and operate the permitted facility in accordance with the statements, representations, procedures, terms and conditions of the permit application, supporting documents and permit. This permit does not relieve the permittee from any duty to obtain any other permit or authorization that may be required by any provision offederal, state or local laws.

In carrying out its activities authorized by this permit, the permittee, owner and operator shall comply with all of the following permit conditions:

Page 10: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

1

2.

The applicant will provide immediate oral or written notice to the Southeast District, Water Quality Division, Herschler Building 4 West, Cheyenne, 'NY, 82002, Phone 307-777-7088, FAX 307-777-7610, in accordance with the provisions of Section 11, Chapter 3, Wyoming Water Quality Rules and Regulations of any changes or modifications which are not consistent with the terms and conditions of this permit.

Separate permits to construct will be required for the improvements necessary to the wells to supply water to a public water system.

3. The concrete pad shall slope away from the well casing to discourage storm drainage and contaminants from remaining near the well casing.

4. Within sixty days of completion of construction of the authorized facility, the applicant will submit to the Southeast District, Water Quality Division, Herschler Building 4 West, Cheyenne, WY, 82002 a certification of completion signed by the Engineer of Record or the owner. A form titled "Certificate of Completion" has been provided.

5.

a. Date that construction of the facility was completed; and

b. Date that the facility was placed in operation; and

c. Certification the facility was constructed in accordance with the terms and conditions of the permit; or

d. Certification the facility was completed with changes or modifications. Submittal of as­constructed plans and specifications for the system as it was constructed, certified by an engineer if appropriate is required. All modifications or deviations from the authorized plans must be highlighted.

e. As a part of the certificate of completion, the Engineer must certify that all Test Wells have been plugged and abandoned as required by Chapter 11, WQD Rules and Regulations.

The review and approval of this permit is based upon the items identified in the attached "Statement of Basis".

AUTHORIZED BY:

Kevi n F red rick Administrator Water Quality Division

·1

Date ofIssuance e>-..\ - \S ' \ '2> SWT/rm/13-0324

"

(

(

(!

Page 11: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

STATEMENT OF BASIS

1. Permit Number: 13-105

2. This application was reviewed for compliance with the applicable regulations;

Chapters 3, 12, 26

3. Does the permit comply with all applicable regulations identified above?

Yes, with the exception of the following variance

A variance from Department of Environmental Ouality Water Ouality Rules and Regulations Chapter 12 Section 9(b)(iii)(C)(JID(2.) requiring the pumping water level to remain above the screen under all operating conditions. This variance is granted to allow access to upper sand lenses in the formation, screen corrosion and scale potential can be maintained by owner, pump will be adequately submersed to alleviate air-lock concerns, and entrained air will be dissipated through storage venting in the future public water supply ")'stem.

4. A review to determine groundwater impacts in accordance with Section 17, Chapter 3 was not required.

Public water supplies are exempted from review by Chapter 3, Section 17.

5. Documentation of Statement of Basis: The archive file for this permit includes adequate documentation of all sections of this Statement of Basis.

CERTIFICATION

The issuance of this permit is based upon a review of the application package submitted in accordance with the requirements of Chapter 3, Section 6, Wyoming Water Quality Rules and Regulations. This review was performed by Seth Tourney, Southeast District Engineer, Water and Wastewater Section, Wyoming Department of Environmental Quality !Water Quality Division, and completed on April 10, 2013. Permit issuance is recommended based upon statements, representations, and procedures presented in the permit application and supporting documents, pennit conditions, and the items identified in this "Statement of Basis. I!

Page 12: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

..

(

(

(

Page 13: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality To protect, conserve and enhance the quality af Wyoming 's

environment for the benefit of current and foture generations.

Matthew H. Mend, Governor

March 28, 2013

Wojslaw Marciniak P.O. Box30a Rawlins, WY 82301

NOTIFICATION OF COVERAGE

RE: Wojslaw Marciniak Replacement Residential Septic System, Application No. 13-106, Carbon County

Dear Mr. Marciniak:

Todd Pal'fitt, Db'ector

The above application for coverage under General Permit to Construct, Install, Modify or Operate a Small Wastewater Facility consisting of a 1000 gallon, two compartment. concrete septic tank. discharging into about 225 feet of chamber type trench legchfield divided into three equal length trenches of at least 18 infiltraiorbrand, Quick4 EQ36 model chamber units each, for a 3 bedroom home, located in the NE'.4 NWV. of Section 13, T21N, R88W, Carbon County, in accordance with Chapter 3, Section 9 of the Wyoming Water Quality Rules and Regulations has been reviewed and is hereby approved, You are authorized to construct, install or modify the small wastewater system in accordance with Chapter 25 of the Water Quality Division Rules and Regulations, the general permit, the condition listed beloW, and the materials submitted in your application package. Your attention is directed to the mandatory reporting requirements outlined in Part V, Section 0 of the general permit. All construction, installation, or modification allowed by this Notification of Coverage shall be completed by March 28, 2015,

The following project specific condition also applies:

Septic Tank ClEoian"Out Riser Requirement - Either a 6 inch diameter clean"out riser or the manway from each compartment of the septic tank must be extended to the ground surface,

HerschlerBuilding • 122 W",t25th Sit'eel . Cheyenne, WY 82002 ' http://dcq •• t.t~wy.u, ADMINlQ1JTREAClI ADANDONEDMINES M.R.QUALl'fY INDUSTRlAJ .. BlTrNG LAND QUALITY SOLI)}&JlAZ. WAm':E WATlC-RQUALITY

(307) 777-7758 (307) 177...ii14S (01)177-7391 (307) 777-1369 (307) 77M1S6 (307) 717-17~2 (301)717-nSl FAX717.76R2 FAX7n6462 FAX 177-$616 FAX 777-5913 FAX 717-5864 ]IAX77'J-5973 FAX 77']-5971

Page 14: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

This Notice of Coverage is covered under the General Permits on the Wyoming Department of Environmental Quality webpage. The General Permits can be viewed althe following path:

!:llli2:lIdeg.state.wy.us/wgd/www/Permitting/Pages/general permits.asp

Please reference Application No. 13-106 in any future correspondence.

If you have any questions, please contact me at either [email protected] or by phone at (307) 777-6183.

Sincerely,

~~~ Ronald L. Ewald Assistant Southeast District Engineer Southeast District, Water & Wastewater Section Water Quality Division

RLElrm/13-0297

Enclosures: Certificate of Completion form

co: IPS, Cheyenne Kristy Rowan, Carbon County Planning Office, Carbon Building, 215 West Buffalo

Street, Suite 336, Rawlins, Wyoming 82301

I ( . ,

! :

Page 15: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality To protfJct, conselVfJ, and anhance /he quality of l11tomlng's

environment for the bfmeflt of current end future genef8tJans.

Matthew H~ Mead, Governor 152 N. Durbin St., Suite 100 • Casper, WY 82601 • (307) 473-3450

April 18, 2013

Birch Negaard P.O. Box 1405 Sundance, WY 82729

NOTIFICATION OF COVERAGE

RE: Negaard Small Wastewater System Application No. 13-107, Crook Couuty

Dear Mr. Negaard:

Todd Parfitt, Director

The above application for coverage under General Permit to Construct, Instail, ModifY or Operate a Small Wastewater Facility consisting of a 1,000 gallon J&D Precast concrete septic tank discharging into fOllr pipe and rock trenches approximately 45 feet in length, for a three bedroom home located in the SW%, Section 32, Township 53N, Range 61W, Crook County, in accordance with Chapter 3, Section 9 of the Wyoming Water Quality Rules and Regulations has been reviewed and is hereby approved. You are authorized to construct, install, or modifY the facility in accordance with Chapter 25 of the Water Quality Division Rules aud Regulations, the general permit, and the materials submitted in your application package. Your attention is directed to the mandatory reporting requirements outlined in Part Y, Section 0 of the general permit. All construction, installation, or modification allowed by this Notification of Coverage shall be completed by December 31. 2014.

This Notification of Coverage is covered under the General Permits on the Wyoming Department of Environmental Quality webpage:

http://deq.state.wy.lIs/wqd/www/Permitting/Pages/general-1)ermits.asp

Additionally, the following permit condition applies: 1. Cleauouts are required every 100 feet and at all changes in direction 22.5 degrees and greater. 2. Flow"divider tecs 01' a distribution box is required to cvenly split flow between trenches. Standard tees are

not an adequate substitute for flow"dividing tees.

lfyoll have any questions, please contact me at 307-473-3469.

Sincerely, ~ /;?" ?~2'J

Jason Vreeland, P.E. Assistant NE District Engineer WDEQ/WQD

cc: IPS, Cheyenne WDEQ Casper File Tim Lyons, Crook County Growth and Development Mac's ConR1:ruction, p.o. Box 124, Sundance, WY 82729

Che,r,nne 122 West 25 Street 82002

(301) 777-7937

Lander 5!() Meadowview Drive 82520

(307) 332·3144

Sheridan 2100 W. 5" Sireet 8280 1

(307) 673-9337

Page 16: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(i

(

Page 17: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

REVIEW OF PLANS & SPECIFICATIONS WYOMING DEPARTMENT OF ENVIRONMENTAL QUALITY

WATER QUALITY DIVISION

PROJECT: Negaard Small Wastewater System

APPLICANT: Birch Negaard, P.O. Box 1405, Sundance, WY 82729

INSTALLER: Gerald McInerney, P.O. Box 124, Sundance, WY 82729

WATER QUALITY DIVISION APPLICATION NUMBER: 13-107

REVIEWING ENGINEER: Jason Vreeland, P.E. 307.473.3469 or [email protected]

DATE OF REVIEW: April 3, 2013

ACTION: NOT AUTHORIZED FOR CONSTRUCTION. In accordance with Section 12(a), Chapter 3, Wyoming Water Quality Rules and Regulations (WWQRR), this application is not granted. Please address the comments outlined below and submit the requested information in order that the application process may be completed in accordance with Section 9 of Chapter 3 of the WWQRR. If the applicant fails to provide the requested information within one month, the incomplete application shall be returned.

I. Please complete all applicable sections of the latest version of the conventional septic system application packet included with this review. Please use this application packet for future projects.

2. The percolation rate was calculated incorrectly. Test hole #1 had a final drop of I 1/8 inch which would yield a percolation rate of 9 mpi. Please revise the calculations accordingly.

3. Please clarify the depth of rock below the pipe. The earlier section indicates a depth of 12 inches where the later section indicates a depth of 6 inches.

Please make the required corrections and return to Wyoming Department of Enviromnental Quality, Water Quality Division, 152 North Durbin Street, Suite 100, Casper, Wyoming 82601.

Page 18: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(

(

Page 19: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

REVIEW OF PLANS & SPECIFICATIONS WYOMING DEPARTMENT OF ENVIRONMENTAL QUALITY

WATER QUALITY DIVISION

PROJECT: Humes Small Wastewater System

APPLICANT: Rob Humes, 140 Salt Creek Road, Newcastle, WY 82701

INSTALLER: Owner

WATER QUALITY DIVISION APPLICATION NUMBER: 13-108

REVIEWING ENGINEER: Jason Vreeland, P.E. 307.473.3469 or [email protected]

DATE OF REVIEW: April 4, 2013

ACTION: NOT AUTHORIZED FOR CONSTRUCTION. In accordance with Section 12(a), Chapter 3, Wyoming Water Quality Rules and Regulations (WWQRR), this application is not granted. Please address the comments outlined below and submit the requested information in order that the application process may be completed in accordance with Section 9 of Chapter 3 of the WWQRR. If the applicant fails to provide the requested information within one month, the incomplete application shall be returned.

1. The application was incomplete. Please submit pages 23 and 25, or the applicable leachfield design pages of the application packet.

2. The percolation rate was calculated incorrectly. The percolation rate should be calculated as the time interval divided by the final drop value. When conducting three tests the slowest percolation rate should be used. For your test data, Hole #3 had a final drop of 1/8 inch for a percolation rate of 80 minutes per inch. This indicates that the soil in this area may not be suitable for a standard leachfield. If the property has any additional areas that may be suitable for a leachfield, please conduct a percolation test in that area. If there are no other suitable areas on the property, you may be granted a variance to the regulation for this location if a loading rate of 0.25 gpd/ff is used to size the leachfield.

3. Leachfield trenches are required to be less than 100 feet. Please revise the design accordingly.

4. Please revise the site drawing with the location of the replacement leachfield.

Please malce the required corrections and return to Wyoming Department of Environmental Quality, Water Quality Division, 152 North Durbin Street, Suite 100, Casper, Wyoming 82601.

Page 20: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(,

Page 21: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Matthew H. Mead, Governor

June 28, 2013

Rob Humes

Department of Environmental Quality

To protec~ conserve, and enhanca the quality of flYoming's

environment for the benefit of current and future ganeratlons.

152 N. Durbin St., Suite 100 . Casper, WY 82601 . (307) 473-3450

140 Salt Creek Road Newcastle, WY 82701

RE: Return of Application for Humes Small Wastewater System, Application #13-108, Weston County, WY

Dear Mr. Humes:

Todd Parfitt. Director

The Wyoming Department of Environmental Quality (DEQ) received an application form for a Permit to Construct for a small wastewater system in Weston County. Upon review, DEQ determined that the application was not complete and contained deficiencies. Additionally, DEQ has not received a response to the review dated April 4, 2013; therefore, in accordance with Wyoming Department of Environmental Quality/Water Quality Rules and Regulations Chapter 3, Section 14 - Denial of a Permit or Coverage under a General Permit, we are returning all of the submitted application materials to you, as we are unable to process your application as submitted.

We are including a complete design packet to correct any deficiencies noted in the reviewed previously mentioned above.

If you have any questions, please contact me at (307) 473-3469, or [email protected].

Sincerely,

Jason Vreeland, P.E. WDEQ/WQD

cc: Weston County Growth and Development, I West Main Street, Newcastle, WY 82701 IPS WDEQ File

Che~enne 122 West 25' Street 82002

(307) 777-7937

Lander 510 Meadowview Drive 82520

(307) 332·3144

Sheridan 2100 W. S" Street 82801

(307) 673-9337

Page 22: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(

(

Page 23: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality

Matt Mead, Governor

March 29, 2013

Johnny Houge

To protect, conserve and enhance the quality of Wyoming's environment for the benefit of current and future generations.

NOTIFICATION OF COVERAGE

Teton Village Water and Sewer District P.O. Box 586 Teton Village, WY 83025

RE: leton Village Sewer Main Replacement (2013) DEQ Permit #13·109

Todd Parfitt, Director

Located In leton County, SW 14 and SE 14, 824, T42N, R117W; Lal. 43.5860, Long. ·110.8310

Dear Mr. Houge,

This project consists of the replacement of existing clay sewer pipes with HDPE by pipe bursting.

The above application for coverage under General Permit has been reviewed in accordance with Chapter 3, Section 7; and Chapter 11 of the Wyoming Water Quality Rules and Regulations and is hereby approved.

You are authorized to construct, the facility in accordance with the general permit and the materials submitted In your application package and the General Permit to Construct, Install, Modify or Operate a Small Wastewater Facility. Construction shall be completed by October 31,2015 '

Your attention is directed to the attached Certificate of Completion form, which is to be submitted within 60 gays of the completion of the aforementioned project.

These General Permit requirements can be downloaded from the Wyoming Department of Environmental' Quality webpage. The General Permits can be found under the Water Quality Division Water arid Wastewater Program, Engineering and Technical Services at:

http://deq.state.wy.uslwqdlwwwIPermitlinglp~geslgenemLpermils.asp

If you have any questions, please contact Hannes Stueckler at 307·335-6964 or James Brough at 307-335·6961.

He nas E. Stueckler, P.E. A sistant Northwest District Engineer Water Quality Division

xc: PDF to Cheyenne Josh Kilpatrick P.E., Nelson Engineering, P.O. Box 1599, Jackson, WY 83001

Lander Fietd Office' 510 Meadowview Drive' Lander, WY 82520 • http://deq.state.wy.us ABANDONED MINES

(307) 332"5085 l'AX 332-7726

AIR QUALITY (307) 332-6755 l'AX33U726

LAND QUALITY (307) 332"3047 FAX 332"7726

SOLID & HAZARDOUS WASTE: (307) 332-6924 FAX 332·7726

WATER QUAUTY (307) 332-3144 FAX 332-7726

Page 24: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

('

(

Page 25: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

WYOMING DEPARTMENT OF ENVIRONMENTAL QUALITY WATER QUALITY DIVISION

PERMIT NO. 13-110

PERMIT TO CONSTRUCT

Cakebread Ranches Day Lodge -Public Water System No Public Water System Number Assigned ~.

This permit hereby authorizes the applicant

Steve and Jill Cakebread P.O. Box 3529

Alpine. WY 83128

to construct a transient public water supply system consisting of an existing water well. new distribution piping and UV disinfection system to serve a Day Lodge. Gift Shop. Restaurant and Office according to the procedures and conditions of the application number 13-110. The facility is located about 3.5 miles northwest of the Town ofThayne at Long: 111 0 l' 28" Wand Lat: 42° 57' 59" N, in the county of Lincoln, in the State of Wyoming. All construction, installation, or modification allowed by this permit shall be completed by April 17. 2015.

The issuance of this permit confirms that the Wyoming Department of Environmental Quality (DEQ) has evaluated the application submitted by the permittee and determined that it meets minimum applicable construction and design standards. The compliance with construction standards and the operation and maintenance of the facility to meet the engineer's design are the responsibility of the permittee, owner, and operator.

Granting this permit does not imply that DEQ guarantees or ensures that the permitted facility, when constructed, will meet applicable discharge permit conditions or other effluent or operational requirements. Compliance with discharge standards remains the responsibility of the permittee.

Nothing in this permit constitutes an endorsement by DEQ of the construction or the design ofthe facility described herein. This permit verifies only that the submitted application meets the design and construction standards imposed by Wyoming statutes, rules and regulations. The DEQ assumes no liability for, and does not in any way guarantee or warrant the performance or operation of the permitted facility. The permittee, owner and operator are solely responsible for any liability arising from the construction or operation of the permitted facility. By issuing this permit, the State of Wyomiflg doe.s noi waive its sovereign immunity. . .\~\ ., .\ :, ',; • , •.. J," The permittee shall allow authorized representatives from DEQ to enter and inspect any property, premise or place on or at which the facility is located or is being constructed or installed for the purpose of investigating actual or potential sources of water pollution, and for determining compliance or non­compliance with any rules, regulations, standards, permits or orders.

Nothing in this permit shall be construed to preclude the institution of any legal action or other proceeding to enforce any applicable provision of law or rules and regulations. It is the duty of the permittee, owner and operator to comply with all applicable federal, state and local laws or regulations in the exercise of its activities authorized by this permit.

The issuance of this permit does not convey any property rights in either real or personal property or any invasion of personal rights, nor any infringement of federal, state or local laws or regulations.

Page 1 of 3

Page 26: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

The permittee shall construct and 9P!'lratethe pe~mitted facility ill accordance ""ith the statements, representations, procedures, terms j3lld c;ondition~ofthe perrnit~ppli.cation, supporting documents and permit. This permitdoesnot relieve t\lepermittee.frqrnallydl;lty tOqblain any other permit or (. authorization that may berequired by'any provisionoffederal, state or local laws.

In carrying out its activities auth?rized by this permit, the permittee, owner and operator shall comply with all of the following permi(concJitiqn~;.···· . . •. c, .

1of3

20f3

3 of3 .

The apPlicantwinp;o~id~·immediate. ~ral or ~riit~~.~~ti~~t~theWYOming Department' of Environmental Quality, Water QuCllityDivision(WQD), Southwest District Engineer,510

. Meadow YiElwDrive,Lander,WY825?0,.307-332-3144,FAX 307-332-7726, in accordancewiththe provision~?f~eCtiorl 11 i Chapter 3, Wyoming Water Quality Rules and Regulations of any changeso(hlodifications which are not consistent with the terms and coriditionsofthispermit •. .,,,. . Ii,

. , _ '_'-::':,'- :_,:,-'_ :;,::':-::<~':'-':'L.<-- .).:,--_:-:,(:-_- , .. ,,'.-:' __ :' _ .,_',,--- -~:_-,: -'._.,_,,,:. ,-, .. -,-,_i _ _ ,:' :'.'. _, '- --- _' '<''''. __ :-_':,- . -,,-; :-" Within sixtycJClY;;pfc9r:npleti(jn qfconstruction of.theauthorizeg facility,th~ applicant will

• ·submIttp:the~w.!th.""est Districti:!certification pf complelibpsigned bXthe Engineer of Record aOhe qwi'\er,A form titled "Certificate of Cbmpletion'!has been provided.

, _,"_',' "".',c--"o;,.-";-._·,_,_,:,.-·<:_"\-",,,, ,,", _ ._.,' ._.,/ -"._'_,;,;_:,: _:-.. ,;", ,: __ -,-,~._,- ___ ",~-" '_'" ' .

. ·a:8~teth~t~onit:ucli~ri.of~hefacility 'Na~·co~Pletid;and·· b .. Date.that the facility was placed in operation; and .' c.iC~rtificatjc)ri thef~ciIitY'Nasconstructedin ascordancewith the terms and .. :conditionsofthepermit;or'· ....... • .. " ....• ".:' ••• ? ... .

'd;.Certifb3tibh tb~faci lity wascompletedwithchange~Or modifications. '~I.lbiriittal of~s~construciedplans~ndspedficatiqnsfor the system as it was cOf1~fructed, certifiedby an engineer if appropricileisrequired.AII modifications or deviations from the authorized plans must be highlighted.

The reviewaru;lapprOlial of this permit is based upon the items identified in the attached "Statementbf Basis".

AUTHORIZED BY:

~··'a······'··· ................................. ~ ....... '.;. , " -', -', ,"- -,-'" \ .,-

~ ........... .

- . -'" . . .

Kevin D. Frederick Administrator Water Quality Division .. '.

JfI~J~~\3 . Date of Issuance

MDB/rm/13-0346

.. __ ... _._ ...... _ .• _ .. _._ .... _.----

(

(i

Page 27: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

STATEMENT OF BASIS

1. Permit Number: 13-110

2. Application reviewed for compliance with the following regulations:

Yes. Chapters 3. and 12 of the Wyoming Water Quality Rules and Regulations.

Chapter 12. Section 8 (d) (iii) requires an altemative source of power. Since the proposed water system is a transient system a variance is granted.

Chapter 12. Section 8 (b)(i) requires eithertwo water wells or storage. Since the propose water system is a transient system a variance is granted.

Chapter 12, Section 9 (b)(iii)(Dl(IV)(1.) requires that pitless units for water wells be shop fabricated. Since a pitless weld on adapter was installed per the manufacturers recommendations a variance is granted.

Chapter 12. Section 9 (b)(B)(iii)(C)(lV)(1,) requires neat cement grout to be used for 2-inch annular openings between the water well bore hole and casing. Bentonite chips were used to seal the existing water well annular opening. Since water testing does not indicate a seal failure a variance is granted,

3, If a Section 17 of Chapter 3 review is required indicate the basis for determining groundwater will be protected.

Not Required.

4, Documentation of Statement of Basis: The archives file for this permit include adequate documentation of all sections of this Statement of Basis.

CERTIFICATION

The issuance of this permit is based upon a review of the application package submitted in accordance with the requirements of Chapter 3, Section 6, Wyoming Water Quality Rules and Regulations. This review was performed by Mark D, Baron, P.E., [email protected], Southwest District Engineer and completed on April 17, 2013, Permit issuance is recommended based upon statements, representations, and procedures presented in the permit application and supporting documents, permit conditions, and the items identified in this "Statement of Basis."

cc: Brian Lenz, P.E" Jorgensen Associates, P.C., P,O. Box 9550, Jackson, WY 83002

Page 3 of 3

Page 28: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(

(

Page 29: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

STATE OF WYOMING DEPARTMENT OF ENVIRONMENTAL QUALITY

UNDERGROUND INJECTION CONTROL PERMIT ISSUED UNDER WYOMING WATER QUALITY RULES AND REGULATIONS

CHAPTER 16

CLASS V INJECTION WELL

( ) New ( ) Modified (X) Renewal

Permit Number: 13-111 Facility Number: WYS-033-00258 State Subclass: 5E3

In compliance with the Wyoming Enviroumental Quality act (W.S. 35-11-101 through 1104, specifically 301(a)(i) through 301 (a)(iv), Laws 1973, Ch. 250, Section I) and Wyoming Water Quality Rules and Regulations, Chapter 16.

Applicant: Elkhorn Trailer Park Helen and Larry Hanft HC64 192 Beckton Road Dayton, WY 82836

Elkhorn Trailer Park, hereafter referred to as the permittee, is authorized to operate the septic system located in the NEY< of the NWV. of Section 18, Township 55 North, Range 88 West, of the 6th Principal Meridian, Sheridan County, WY. Thc permittee is allowed to operate the facility according to the procedures and conditions of application 13 -III, and requirements and other conditions of this permit.

This permit shall become effective on the date of issuance and is valid for ten (10) years.

Kevin Frederick, Administrator Water Quality Division Herschler Building, 122 West 25th Street Cheyenne, WY 82002 (307)-777-7781

Todd Parfitt, Director Department of Environmental Quality Herschler Building, 122 West 25th Street Cheyenne, WY 82002

CMc/rml13-0791

PERMIT 13-111 Finalized August 21,2013

~- ;;'"J-, ,h I~ Date

Page I of 12

Page 30: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Table of Contents

A. Discharge Zone ................................................................................................................ 3

B. Well and Area of Review .......... " ......................... , .......................................................... 3

C. Groundwater Classification ...................... : ...................................................................... 3

D. Authorized Operations ............................................ " ........ """""'" .................................. 3

E. Hazardous Waste ............................................................................................................ .4

F. Proper Operation and Maintenance ........................ ", ........ """" ",,,,,,,,,,, ........................ .4

G. Entry and Inspection .................... , ....................................................................... , .......... .4

H. Environmental Monitoring Program for Groundwaters of the State .............................. .4

I. Requirements for Monitoring Groundwaters ·ofthe State .... ; .......................... "" ............ 8

J. Test Procedures ................................................................................................................ 9

K. Records and Reports ........................... c ........................................................................... :9

1. Permit Actions ............... " ........................................................................................ , ....... 9

M. Abandonment. ....................................................................... .' ........................................ 1 0

N. Duties of the Permittee .................................................................................................. l 0

O. Signatories Requirement. .................................................... , ............. " ...... .' .................... 1 0

P. Noncompliance .......................................................................................... " .................. 11

Q. Permit Transfer ....................................................... " ... " ... " ........................................... 11

R. Property Rights .............................................................................................................. 12

S. Severability .................................................................................................................... 12

Page 2 of 12 PERMIT 13-111 Finalized August 21, 2013

( (

( (

( I

(

Page 31: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

A. Discharge Zone This injection facility (sanitary leachfield) is authorized to inject 2,280 gallons per day average and 3,800 gallons per day maximum. The primary treated wastewater is injected into the alluvial aquifer. Depth to groundwater in the vicinity of the leachfield is approximately six (6) feet, based on observations made during a subsurface investigation performed in the Spring of 2012, by the permittee's consultant.

B. Well and Area of Review The inj ection well authorized by this permit is located as follows:

NEY. of the NW Y. of Section 18, Township 55 North, Range 88 West, of the 6th Principal Meridian, Sheridan County

The Area of Review is defined as a circular area of 360 acres with the injection facility located near its center.

The Area of Review is based upon the following information:

C. Grouudwater Classification The groundwater in the alluvial aquifer beneath the permittee's property is classified as Class I by quality according to Wyoming Water Quality Rules and Regulations, Chapter 8, Table 1. This classification is made because the groundwater in this formation is currently being used for domestic purposes at nearby points of withdrawal.

Groundwater of Class I shall not be degraded to malce it unusable as a source of water for this purpose. An aquifer that contains less than 10,000 mg/L total dissolved solids (and is not exempted) can be considered an underground source of drinking water.

D. Authorized Operations The operator is authorized to inject at a pressure of no more than atmospheric pressure as measured at the leach fIeld. This pressure is controlled by gravity drainage and is not required to be monitored. The permittee is authorized to inject a maximum of 3,700 gallons per day. The wastewater is produced from a seasonal trailer park with 38 plumbed camp/trailer sites. The wastewater is injected into the unconfined alluvial aquifer. The wastewater is described as primary treated domestic sewage from a septic tank.

PERMIT 13 -111 Finalized August 21, 2013

Page 3 of 12

Page 32: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

If additional sewage flows are added beyond those identified in the permit application, the leach field and/or treatment system may need to be enlarged in which case the pennittee must submit a ( revised application and receive a new permit prior to modification of the leach field or treatment system. (

E, Hazardous Waste This permit does not allow for the inj ection of any hazardous waste as defined in 40 CFR 261.3 and in Wyoming Solid Waste Management Rules and Regulations, Chapter 2. Injection of any substance defined as a hazardous waste, whether hazardous. by listing or by characteristic is a violation of this permit.

F, Proper Operation and Maintenance The permittee shall take all reasonable steps to minimize or correct any adverse impact on the environment resulting from noncompliance with this permit. . The flermittee shall operate and maintain all facilities and systems of treatment and control which are installed or used by the pennittee to achieve compliance with the conditions of the pennit. Proper operation and maintenance includes: effective perfonnance, adequate funding, operator staffing and training, and laboratory and process controls, including appropriate quality assurance procedures. This provision requires the operation of back-up or auxiliary facilities or similar systems only when necessary to achieve compliance with the conditions of this permit. The injection wells covered by this pennit shall meet all construction requirements' outlined in Wyoming Water Quality Rules and Regulations, Chapters 11, 16 and 25.

The permittee is required to operate in accordance with statements, representations and ( procedures presented in the complete permit application and supporting documents its accepted and approved by the Administrator. Any modifications Which will result in a violation of permit ( conditions shall be reported by submission of a new or amended permit application and shall not be implemented until a new or modified permit has been issued. Injection into a well may not begin until construction is complete and the permit is approved.

G, Eutry and Inspection The permittee shall allow the Administrator (upon presentation of credentials and during normal working hours) to enter the premises where a regulated facility is located, or where records are kept under the conditions of this permit and inspect and photograph the discharge and related facilities, review and copy reports and records required by this permit, collect fluid samples for analysis, measure and record water levels, and perfonn any other function authorized by law or regulation.

H. Environmental Monitoring Program for Groundwaters of the State General Requirements:

I. Samples and measurements taken for the purpose of monitoring shall be representative of the monitored activity. A groundwater sample is considered representative of the aquifer being monitored when the well has been purged to remove stagnant water prior to collection of a sample for laboratory analysis. Purging can be considered complete when a sufficient volume of water has been removed from the well and stabilization of select groundwater parameters

Page 4 of 12 PERMIT 13-111 Finalized August 21,2013

( (

Page 33: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

has been achieved. It is important to record the circumstances surrounding each sample collection event at your facility. These records can help resolve analytical discrepancies. One or both purging methods below shall be used prior to sample collection:

a. Purge by Volume Method Removal of a minimum of three (3) casing volumes of water from the well should be completed prior to collecting a groundwater sample. Minimum purge volume can be calculated by the following equation:

Minimum Purge Volume = 3 * «Total Well Depth in feet - Depth to Waterin feet) * Well Capacity) Where Well Capacity (gallons per foot) is based on well diameter:

2 inch well = 0.163 6 inch well = 1.47 4 inch well = 0.653 8 inch well = 2.61

b. Stabilization of Parameters Method Purging of groundwater until select field parameters have stabilized can be used to demonstrate that a representative sample was collected. Field parameters measured during purging should include at a minimum temperature, pH, and specific conductance. Field parameters should be measured after removal of every half casing volume of water.

Half Casing Volume = 0.5 * «Total Well Depth in feet - Depth to Water in feet) * Well Capacity)

Where Well Capacity (gallons per foot) is based on well diameter: 2 inch well = 0.163 6 inch well = 1.47 4 inch well = 0.653 8 inch well = 2.61

A minimum of six (6) parameter measurements should be collected. If field parameters have not stabilized between the last three readings, purging and parameter measurement should continue until stabilization has been achieved. Stabilization can be demonstrated by a variance of no more than +/- 10% for temperature and specific conductance, and +/-0.2 standard units for pH.

2. The permittee shall retain records of all monitoring information including all calibration and maintenance records, copies of the reports required by this permit, and records of all data used to complete the application for this permit, for a period of at least three (3) years from the date of the sample measurement, report, or application. This period may be extended by request of the Administrator at any time.

3. The permittee shaH use electronic data deliverable (EDD) reporting when required by the Administrator.

4. Records of monitoring information shall include:

a. The date, exact place, and time of sampling or measurements;

Page 5 of 12 PERMIT 13-111 Finalized August 21, 2013

Page 34: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

b. The initials or name(s) of the individual(s) who performed the sampling or measurements;

c. The date(s) analyses were performed; d. The time(s) analyses were initiated; e. The initials or name(s) of the individual(s) who performed the analyses; f. References and written procedures for the analytical techniques or methods used; g. The results of such analyses, including the bench sheets, instrument readouts, computer

disks or tapes, etc., used to determine these results.

5. Monitoring must be conducted according to test procedures approved under 40 CFR Part 136, unless other test procedures have been specified in this permit.

6. The permittee shall retain all records concerning the nature and composition of injected fluids until five (5) years after completion of any specified plugging and abandomnent procedures. The administrator may require the owner/operator to deliver the records to the administrator at the conclusion of the retention period.

7. The permittee shall report any noncompliance which may endanger health or the environment within twenty-fom (24) hours from the time the operator becomes aware of the circumstances. The report should include:

a. Any monitoring or other information which indicates that any contaminant may cause an endangerment to a usable groundwater of the state;

( (

b. Any noncompliance with a permit condition or malfunction of the discharge (injection) ( system which may cause fluid migration into or between usable ground waters of the

c. ~a~itten submission shall be provided within five (5) days of the time the operator (. becomes aware of the circlunstances. This written submission shall contain a description of the noncompliance and its cause; the period of noncompliance, including exact dates and times, and if the noncompliance has not been corrected, the anticipated time it is expected to continue; and steps taken or plarmed toredllce, eliminate, and prevent reoccurrence of the noncompliance.

8. The permittee shall report all instances of noncompliance not reported otherwise, at the time monitoring reports are submitted.

9. The monitoring reports shall be submitted on forms provided by the Department. Reports of compliance or noncompliance with, or any progress reports on, interim and final requirements contained in any compliance schedule of this permit shall be submitted no later than forty- five (45) days following each schedule date.

10. A new monitor well (MW-l; see Table 2) shall be constructed downgradient and north of the existing leachfields by December 31, 2013. The monitor well shall be drilled until a saturated aquifer is reached and be at least 20 feet in depth. The monitor well shall be screened into this aquifer, with the screen placed across the static water level. This well shall be sampled for baseline ground water constituents listed in Wyoming Water Quality Rules

PERMIT 13-111 Finalized August 21, 2013

Page 6 of 12

( (

Page 35: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

and Regulations, Chapter 8, Table I and reported to the Department upon completion of the well.

11. The permittee's public supply spring (P29347D), which is located cross-gradient, is required to have a one-time baseline sample taken to analyze for Nitrate, Ammonia, Chloride, pH, and Total Coliform.

THIS AREA WAS INTENTIONALLY LEFT BLANK

PERMIT 13-111 Finalized August 21, 2013

Page 7 of 12

Page 36: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

I. Requirements for Monitoring Groundwaters of the State The groundwater in the receiving formation shall be sampled and the following parameters analyzed according to the schedule identified in Table 2. The following parameters shall be analyzed semi-annually and reported annually:

MW-l Semi-Annually

Nitrate-Nitrite as N Monitor well,

down gradient of (January-June and

I Chloride -'vv.v, -,vv.J., VJ. '.l.LV.IJ, "TJ."'TV.LJ, VJ.

2S0 mgIL July-December) 3S3.2 4S00-CI leachfield

pH (standard units; s.u.) IS0.1 or ISO.2 4S00-H+B 6.S-8.S s.u. measure as soon as

pos~i1

Total volume Flow meter reading 3,800 gpd N/A Septic Tank,

u. .... wv ...... J.HVUUJ.Jj

Annually Sludge depth in tanks

Visual 2 feet N/A

* All applicable chemical concentrations in this permit are expressed as total (not dissolved) in mgIL unless otherwise noted.

, The septic tanks serving the Elkhorn Trailer Court are to be inspected, at a minimum, annually and must be pumped as necessary based on sludge depth at bottom of the septic tank, and at least once every five (5) years. A copy of the invoice for pumping the tanks is to be included with the annual report. Sludge depth is not to exceed 24 inches in the septic tank.

All annual reports are to.be reported within forty-five (45) days of the last day of each year (February 15th).

The above upper control limits (DCL) cannot be exceeded in any sample. Exceedance of these values is a violation of this permit and shall require notification under Section K of this permit. If the VCL is exceeded in a sample, additional monitoring wells may be required to determine whether groundwater has been impacted and to delineate the nature and extent of any contamination resulting from operation of the permitted facility.

PERMIT 13-111 F~ed August 21, 2013

Page 8 of12

~ .,-.,

Page 37: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

J. Test Procedures All samples and measurements taken for the purpose of monitoring shall be representative of the monitored activity. All samples taken shall include a trip blank of distilled water for each sampling date and a duplicate sample at least once per year. All required analyses shall be conducted in compliance with Wyoming Water Quality Rules and Regulations, Chapter 8, Section 7.

K. Records and Reports The permittee shall furnish to the Administrator within a specified time any information which the Administrator may request relating to the operation of the facility, including copies of records required to be kept by this permit. The permittee shall retain copies of all records and reports required by this permit for a period of three (3) years following permanent well abandonment. After that time, those records shall be delivered to the Administrator for disposal or archive at his discretion. Confirmed noncompliance resulting in the migration of injected fluid into any zone outside the permitted receiver shall be reported to the Administrator within twenty-four (24) hours, and a written submission (via certified mail) shall be provided within five (5) days of the time the permittee becomes aware of the excursion. The written submission shall contain: a description of the noncompliance; the period of noncompliance, including exact dates and times, and if the noncompliance has not been controlled, the anticipated time it is expected to continue; and a list of the steps taken or planned to reduce, eliminate, and prevent the recurrence of the noncompliance. Confirmed noncompliance not already reported under this section shall be reported at the time monitoring reports are submitted. The reports shall contain the same information as required by the paragraph above. The permittee shall notifY the Administrator thirty (30) days in advance of any planned alteration, conversion, or abandonment of the well covered by this permit.

L. Permit Actions This permit is authorized for a period of ten (10) years. If the permittee wishes to continue injection after the expiration date of this permit he shall apply to the Administrator and obtain a new permit. The application should be submitted at least 180 days before the expiration date of this permit. Under this permit, the Department may consider injection after the expiration date a violation ofthe permit.

It shall not be a defense for the permittee in an enforcement action that it would be necessary to halt or reduce the permitted activity in order to maintain compliance with the conditions of the permit. The :filing of a request by the permittee, or at the instigation of the Administrator, for permit modification, revocation, termination, or notification of planned changes or anticipated noncompliance shall not stay any condition of this permit.

After notice and opportunity for a hearing, a permit may be modified, suspended or revoked in whole or part during its term for cause which includes, but is not limited to any of the following:

I. Violation of this permit; or 2. Obtaining a permit by misrepresentation of facts in the application.

PERMIT 13-111 Finalized August 21, 2013

Page 9 of 12

Page 38: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

This permit will be reviewed at least once every five (5) years, and may be reviewed more frequently. A permit may be modified at any time as may be required, including for conformity (. with changes in regulations or standards which occur after the permit was issued. A permit may be modified in whole or part in order to apply more or less stringent standards; or prohibitions for toxic or other substances present in the permittees discharge as may be ordered by the Environmental Quality Council.

M. Abandonment General Requirements:

1. The permittee shall notify the administrator at least thirty (30) days prior to abandonment of the facility.

2. An abandonment report, detailing the compliance with abandonment procedures outlined in the original application for coverage under this permit, or describing any deviations from the original plan, shall be submitted as soon as practicable after abandonment. The abandonment shall include reclamation of the well site.

3. Injection wells covered by this permit shall be abandoned in accordance with Wyoming Water Quality Rules and Regulations, Chapter 16, Section 12.

N. Duties ofthe Permittee The permittee shall give advance notice to the Administrator as soon as possible of any planned physical alteration or additions, other than authorized operation and maintenance, to the permitted facility and receive authorization prior to implementing the proposed alteration or addition. The permittee shall furnish the Administrator within a reasonable time any information ( which the Administrator may request to determine whether cause exists for modifying, revoking, or reissuing, or terminating this permit, or to determine compliance with this permit; and to furnish to the Administrator upon request, copies of records required to be kept by this permit. Any modification which may result in a violation of a permit condition shall be reported to the Administrator, and any modification that will result in a violation of any permit conditions shall be reported to the Administrator through the submission of a new or amended permit application. The permittee shall report all instances where he becomes aware that he failed to submit any relevant facts in the permit application, or where he submitted incorrect information in a permit application or in any report to the Administrator, and shall promptly submit such facts or information.

If any cultural materials are discovered during construction, work in the area should halt immediately. The Administrator and the Wyoming State Historic Preservation Office shall be contacted (777-7697) and the materials shall be evaluated by an archaeologist or historian meeting the Secretary of the Interior's Professional Qualification Standards (48 FR 22716, Sept. 1983).

O. Signatories Requirement All reports filed in conjunction with this permit shall contain the following certification:

"I certify, under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel (

PERMIT 13·111 Finalized August 21,2013

Page 10 of 12

Page 39: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations."

All reports required by this permit and other requested information shall be signed as follows:

For a corporation - by a principal executive officer of at least the level of vice-president;

For a partnership or sole proprietorship - by a general partner or the proprietor, respectively;

For a municipality, state, federal, or other public agency - by either a principal executive officer or ranking elected official; or

By a duly authorized representative for any of the above. A person is a duly authorized representative only if:

1. The authorization is made in writing by one of the prescribed principals; 2. The authorization specifies either an individual or position having responsibility for the

overall operation of the regulated facility or activity; and 3. The written authorization is submitted to the Administrator.

If an authorization is no longer aCCUl'ate because a different individual or position has responsibility for the overall operation of the facility, a new authorization must be submitted to the Administrator prior to or together with any reports or information, to be signed by the new authorized representative.

P. Noncompliance The permittee shall comply with all conditions of the permit. Any permit noncompliance constitutes a violation of Wyoming Water Quality Rules and Regulations, Chapter 16 and is grounds for enforcement action, permit termination, revocation, or modification. Conformed noncompliance resulting in an excUl'sion shall be reported to the Administrator orally within twenty-four (24) hours, and a written submission shall be provided within five (5) days of the time the permittee becomes aware of the excursion. The written report shall contain the sections specified in Section K of this permit. Any permit noncompliance constitutes a violation of this permit.

The filing of any request by the permittee for a permit modification, revocation and reissuance, or tennination, or a notification of planned changes or anticipated noncompliance, does not stay any permit condition.

Q. Permit Transfer

Any transfer of this permit shall be accomplished by the submission of the proper forms for permit transfer to the Administrator. Transfer of this permit must first be approved by tile Administrator and the Director. No transfer shall be approved unless the proposed permittee

Page 11 o£12 PERMIT 13-111 Finalized Augnst 21, 2013

Page 40: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

agrees to bring any and all noncompliance issues into compliance with this permit. The permittee is alone responsible for the operation of the facility covered by this permit. Sale of the ( facility and subsequent operation of this facility by another is a violation. of this permit unless a transfer of this permit has first been accomplished.

R. Property Rights This permit does not convey any property rights of any sort or any exclusive privilege. This permit does not authorize injury to private property or any invasion of personal rights, nor any infringement of federal, state, or local laws or regulations.

S. Severability

Nothing in this permit shall be construed to preclude the institution of any legal action or to relieve the permittee from any responsibilities, liabilities, or penalties established pursuant to any applicable state law or regulation.

PERMIT 13-111 Finalized August 21,2013

-End of Permit-

Page 12 of 12

(

(

Page 41: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality

Matthew II. Mead, Governor

August 22, 2013

Elkhorn Trailer Park Attn: Larry Hanft HC64, 192 Beckton Road Dayton, WY 82836

To protect, conserve and enhance the quality of Wyoming 's

environment for the benefit of current and future generations.

RE: Elkhorn Trailer Court, WYS-033-002S8 Permit 13-111, Class V Septic System Permit Sheridan County, Wyoming

Dear Mr. Hanft:

Todd Parfitt, Director

Attached please find one copy of the Class V septic system permit for the facility referenced above. The permit requires a one-time sampling of the water supply from the spring that services this facility, as well as a one-time baselihe sampling of the new monitor well that is to be installed downgradient of your leachfield (Section H, Items 10 & II). This permit also requires semi-annual sampling ofMW-1 and rumual inspection and periodic pumping of the septic tanks (Section I). The corresponding report forms can be filled out using our on-line webform (Monitor Reports Link). For your convenience, the Wyoming Department of Enviromnental Quality (WDEQ) has printed the inspection forms and enclosed them in this mailing. Please use the exact well names used in your permit when reporting data to avoid any miscommunications.

The underground injection control program was promulgated to prevent serious problems caused by direct discharges to the groundwater. Those problems included groundwater pollution leading to contamination in domestic water wells and serious health affects caused by exposures to toxic substances and water borne pathogens. Your cooperation with our program is sincerely appreciated.

If you have any questions please do not hesitate to contact me at the below referenced pbone number or email.

Sincerely,

~ Carol McAdams, GIT Wyoming Department of Environmental Quality Water Quality Division (307) 777-2960 carol.mcadams@W)'o.gov CMc/rm113-079I

Enclosure: Final Permit #13-111 Monitoring Report Forms

cc: John Passehl, WDEQ

Herschler Building' 122 West 25th Street· Cheyenne, WY 82002 . http://deq.state.wy.us ADMIN/OUTREACH

(307) 777-7758 FAX 777-7682

ABANDONED MINES (307) 777-GI4S FAX 777-6462

AIR QUALITY INDUSTRIAL SITING (307)777-7391 (307) 777-7369 FAX 777-5616 FAX 777-5973

LAND QUALITY SOLID & HAZ. WASTE (307) 777-7756 (307) 777-7152 FAX 777-5864 FAX 777-5973

WATER QUALITY (307) 777·7781 FAX 777·5973

Page 42: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

( ..

(

Page 43: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality

Matthew H. Mead, Governor

April 23, 2013

Mr. Brian J. Edwards

To protect, conserve and enhance the quality of Wyoming's

environment for the benefit of current and future generations.

Hohn, Blough and Company Consulting Engineers and Land Surveyors 1402 Stampede Ave. Cody, WY 82414

RE: Yellowstone Valley Inn - Replacement of Septic Systems #2, #3, and #4 Facility Number WYS-029-00 148, Pennit# - 13-112, Class V Injection Wells Park County, Wyoming

Dear Mr. Edwards:

Todd Parfitt, Director

Attached, please find comments developed by the Wyoming Department ofEnvironmental Quality (WDEQ) with respect to the content and adequacy of the Wyoming Water Quality Rules and Regulations, Chapter 13, request for modification of a Class V Injection Well Permit.

The WDEQ received this request for modification on March 6, 2013 and has until May 4, 2013 to make an initial determination of completeness. Re-submittal of infonnation by an applicant on an incomplete application will begin a new 60 day review process. Pursuant to Chapter 13, Section 6 during any 60 day review period where an application is detennined complete, a draft pennit for issuance or denial shall be prepared and a public notice provided pursuant to Chapter 13, Section 19.

Please feel free to contact me at (307) 777-8275 should you have any questions related to these comments or the application and review process.

tf/~~~~ ~!J.G. Wyoming Department of Environment a Quality Project Geologist Water Quality Division

NT/rm/13-036 I

Attachments: WDEQ Comments cc: John Passehl, WDEQ

Ron Jordan, Yellowstone Valley Inn, 3324 Yellowstone Park Highway, Cody, WY 82414

Page 1 of3 Herschler Building' 122 West 25th Street· Cheyenne, WY 82002 . http://deq.state.wy.ns

ADMINfOUTREACH ABANDONED MINES (307) 717-7758 (307) 177-6145 FAX 777-1682 FAX 777-6..f62

AIR QUALITY (307) 777-7391 FAX 777-5616

INl)USTRIAL SITING (307)777-7369 FAX 777-5973

LAND QUALITY SOLID & lIAZ. WASTE (307) 777-7756 (307) 777-7752 FAX 777-5864 FAX 777,·5973

WATER QUALlTY (307)777-7781 FAX 777-5973

Page 44: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

('

(

(!

Page 45: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

UNDERGROUND INJECTION CONTROL PROGRAM REViEW COMMENTS:

PLANS/SPECIFICATIONSIPROPOSALSIREPORTS

WYOMING DEPARTMENT OF ENVIRONMENTAL QUALITY WATER QUALITY DIVISION

PROJECT:

LOCATION:

APPLICANT:

OWNER:

Herschler Bldg., 4 West Cheyenne, Wyoming 82002

307-777-7781

Application 13-112 Yellowstone Valley Inn Septic System #2, #3, and #4 replacement

Park COlll1ty

Ron Jordan, owner Yellowstone Valley Inn 3324 Yellowstone Park Highway Cody, WY 82414

Ron Jordan

CONSULTANTS:

GEOLOGIST

ENGINEER

TITLE:

PLANS

none listed

Brian J. Edwards Holm, Blough and Company Consulting Engineers & Land Surveyors 1402 Stampede Ave Cody, WY 82414

"Replacement of Septic System #5"

SPECS -.X PROPOSAL REPORT

DATE ON PROPOSALIPLANSIREPORT: March 3, 2013

DATE RECEIVED BY WDEQ:

WDEQ REVIEWER:

DATE OF THIS REVIEW:

March 6, 2013

Nicole Twing, Geologist Ron Ewald, Engineer

April 22, 2013

ACTION: Application Incomplete; See Attached Comments REVIEW COMMENTS:

Page 2 of3

Page 46: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

('

(

(:

Page 47: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

e Ie Technical Engineering Review Extent - The extent of the technical engineering review was limited to the replacement of Septic Systems SS-2/lNJ-2, SS-3/lNJ-3, and SS-4/lNJ-4 only, as per the March 6, 2013 request for system replacement. The replacement systems for these septic systems were reviewed for system design loads, septic tanks, sizing, and design ofleachfie1ds, and the layout of the systems. Based on the application, SS-2 will be replaced and SS-3 and SS-4 will be combined into one new systeme

2. Abandonment: How will the septic tanks and lines from SS-2, SS-3, and SS-4 be abandoned?

3. Effective Length of Ouick4 Chamber Units: When connected together, a Quick4 chamber unit only add 4.0 running feet (ft) to the length of the chamber row. In other words, when placed in position, the effective length is 4.0 ft, not 4.5 ft. This will affect the total length ofthe design trenches (add 5 ft for end caps).

4. Minimum Number of Chamber Units Required: When calculating this number, always round up to the nearest whole number.

5. Minimum Required Distance Between Trenches to be Used as a Replacement Leachfield Area: The minimum required distance between trenches is an absolute minimum of 9.0 ft, not +1- 9 ft. To allow for variation during digging, 10 feet of undisturbed soil between trenches is recommended to ensure that the in-between space is useable as a trench replacement area.

6. Clean-Outs: Will there be clean-outs installed at changes of direction or junctions ofthe sewage collection pipes, or at no more than 100 foot intervals? Please show the locations of any clean-outs on the plans.

7. Total Facility RevisedlUpdated Design Flow: Please indicate what the revised/updated total design flow for the entire YVI UIC facility is after these changes. Break it down sub-system by sub-system, including the systems that are not being changed in this application.

8. Percolation Test Locations and Report: Where were the referenced percolation (perc) tests done at onsite? How is this area 'similar' to the proposed construction areas? Please include the referenced perc tests done by Jones Engineering.

9. Replacemcnt Systcm SS-2/INJ2:

a. Location ofthe Four Additional RV Spaces - Where are the four additional RV space that will be connected to this system located? How are they connected to the system?

be Maximum Length of Chamber Trenches - The three chambers for this replacement system are designed to be 105 feet long. From experience, the DEQ recommends that chamber trenches be no longer than 80 feet long. You may wish to consider 4 trenches instead of 3 trenches.

10. Replacement System SS-314/ INJ-3/4:

a. Leachfield Trench Layout - The plans for this leachfield show three trenches all of different lengths. There is room to layout three trenches of equal length.

Page 3 oB

Page 48: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(,

(

Page 49: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Matthew H. Mead, Governol'

April 4, 2012

Cheyenne BOPU

Department of Environmental Quality To protect, conserve and enhance the quality a/Wyoming's

environment for the benefit of current andfuture generations.

NO'l1FICATION OF COVERAGE

Attn: JeffPecenka, Engineer 2416 Snyder Avenue Cheyenne, Wyoming 82001

RE: 2013 Sewer Manholes Project Application No. 13·113, Laramie Connty

Dear Mr. Pecenka:

Todd Parfitt, Director

The above application for coverage under General Permit to Construct, Install, ModifY or Operate Extensions to or Modifications of Existing Public Sewage Collection Systems consistulg of replaCing existing miscellaneous sanitary manholes in the SanIe location with the sanIe diameter that are located within the service area for Cheyenne BOPU, Lammie County, in accordance with Chapter 3, Section 9 of the Wyoming Water Quality Rllies and Regulations has been reviewed and is hereby approved. You are authorized to construct, install or modify Ihe water distribution system in accordance with Chapter 11, Section 9 oflhe Water Quality Division Rules and Regulations, in accordance with the general permit and the materials submitted in your application package. Your atteution is directed to the mandatory reporting requirements outlined in Part Y, Section 0 of the general permit.

All consll'Uctlon, installation, ol'lnodification allowed by this Notification of Coverage shall be completed by April 23, 2018.

This Notice of Coverage is covered under the General Permits on the Wyoming Department ofElIvironmelltal Quality webpage. The General permits can be viewed at the following path:

ht\ll:lldcg.staie.wy.us/wgd/www/Permitting/Pages/geneml penults.asp

Please reference Application No. 13·1.13 in any future correspondence. If you have any questions, please contact me at either [email protected] or by phone at (307) 777·7088.

Sincerely,

~c2 Seth Tomney, P.E. ~ Southeast District Eugineer Water Quality Division

SWT/nn113·0314 Enclosures: Certificate of Completion form co: IPS

----~" ............ '-"-" ..... ~,.~.~. ="~ .. -.~.~. '~""~"'~'-------------------~~--~~~~""-""~'~."".""=-. ·:"HerschlcrBuilahig"· 122 West 25th Street· Cheyenne, WY 82002 . http://deq,statll.WY'WUSAT~'Q··:':LI· T" (I, .;.'~' ..

ADMINlOm'MACH ABANDONED MlNES AlR QUALITY INDUS1'JUAL SITING LAND QUALrl'Y SOJ.,ID & HAZ. WASTl'j ... ~.......~ ~ (307)777-775" (307)'771-614S (30'l)'tn-7391 (J01) 71H3M (01)"717-7156 (9:07)771.7152 {307!'l77-1781 l?A.X7'17-7682 FAX 771-6452 FAXn1·5616 FAX 717-5'l13 FAJ0'11-Sl!64 FAX 177-5913 FAX 771-5973

Page 50: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(

Page 51: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Matthew H. Mead, Governor

April 23, 2013

Department of Environmental Quality To protect, conserve and enhance the quality of Wyoming's

environment fol' the benefit of c"rrenl and future generations.

NOTIFICATION OF COVERAGE

City of Laramie Department of Public Works Attn: Richard Elliott, Director of Public Works P.O. Box C Laramie, WY 82073

RE: South Laramie Water Supply Project Application No. 13-114, Albany County

Dear Mr. Elliott:

Todd Purfitt, Oirectol'

The above application for coverage under General Permit to Construct, Install, Modify or Operate Extensions to or Modifications of an EXisting Public Water Supply Olstributlon System consisting of a total of approximately 11 ,000 feet of 12" PVC C900 DR14 and 8,000feet of 14" PVC C905 DR14watermain, new gate valves, fire hydrants, and air/vac vaults as specified, and two Pressure Reducing Valve vault stations, located in theSE% of Section 9, the NE%& Wv. of Sec 10, and the SE%ofSec 3, T15N, R73W,Albany County, in accordance with Chapter 3, Section 9 ofthe Wyoming Water Quality Rules and Regulations has been reviewed and is hereby approved. You are authorized to construct, install or modify the water distribution system in accordance with Chapter 12, Section 14 of the Water Quality Division Rules and Regulations, in accordance with the general permit, and the materials submitted in your application package. Your attention is directed to the mandatory reporting requirements outlined in Part V, Section 0 ofthe general permit. All construction, installation, or modification allowed by this Notification of Coverage shall be completed by April 22, 2015.

This Notice of Coverage is covered underthe General Permits on the Wyoming Department of Environmental Quality webpage. The General permits can be viewed at the following path:

hltp:/ldeg.state.wy.uslwgd/www/Permilting/Pages/general permits.asp

Please reference Application No. 13-114 in any future correspondence.

If you have any questions, please contact me at either [email protected] phone at (307) 777-6183.

Si~~~ Ronald L. Ewald Assistant Southeast District Engineer Water Quality Division

RLElrm/13-0351 Enclosures: Certificate of Completion form cc: IPS, Cheyenne

Lynn Hill, DOWL HKM, 1575 North 4th Street, Suite 105, Laramie, WY 82072

HerschJ.er Building· 122 West 25th Street· Clteyenne, WY 82002 . http://dcq.state.wy.us AlJMINfOOTlillACll ABANDONED MINES

po']) 771"1758 (07) 777·6145 FAX7n76R2 FAX 717·5462

AIR QUALITY INDUSTRIAL SITING LAND QUALITY SOU}) & BAt, WASTE WATER QUAL11'Y (01)117-7391 (3rJ1) 777-7369 (307)717-1156 (307)777-7752 (301)117-7781 PAX 777k S$16 FAX 777-5973 FAX 177-5854 FAX 777-5973 FAX '111.5973

Page 52: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(

(

Page 53: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality To protect, conserve and enhance the quality afWyoming's

environment for the benefit of current andfoture generations .

. NOTIFICATION OF COVERAGE

May 24,2013

City of Laramie Attn: Dave Derragon, Public Works Director 405 Grand Avenue (p.O. Box C) Laramie, Wyoming 82070

RE: Laramie 2012 8PT Project-Phase 3 Schedule 4 _19'h Street Waterline, Application No. 13-116, Albany County

Dear Mr. Derragon:

The above application for coverage under General Permit to Constrnct, Install, Modify or Operate Extensions to or Modifications of Existing Public Water Supply Distrihution Systems consisting ofinstaIJing approximately 1250 LF of 10-inch and 285 of 8-inch PVC water main located In the South y" Section 34, TI6N, R73W, Albany County, in accordance with Chapter 3, Section 9 of the Wyoming Water QUality Rules and Regulations has been reviewed and is hereby approved. You are authorized to construc~ install or modify the water distribution system iu accordance with Chapter 12, Section 14 of the Water QuaIiiy Division Rules and Regulations, in accordance with the general permit, the conditions listed below, and the materials submitted in your application package. Your attention is directed to the mandatory reporting requirements outlined in Part V, Section 0 of the general.permit. Additionally, the following project specific conditions also apply:

1. Section 2665 E.6 - Watertight plugs shall be maintained in all pipe openings in a trench any time pipe laying is not in progress or the trench is unattended.

All construction, installation, or modification allowed by this Notification of Coverage shall be completed by May 24, 2018.

This Notice of Coverage is covered under the General Permits on the Wyoming Department of Environmental Quality webpage. The General permits can be viewed at the following path:

http://deq.state.wy.us/wqdlwwwlPermitting/Pages/genel'al permits. asp

HerschlerBnilding • 122 West 25th Street· Cheyenne, WY 82002 • http://dL'q.state.wy.lls ADM1NlOUTREACIl AHANDONEDMIl"{ES AIR QUALITY INDUSTRULSITING LANDQUALTIY SOLID &HAZ. WASTE WATER.QUALITY

(3tl-1) 717-775& (307)n7-6145 (307) 77'J.7391 (301)777·7369 FAX 777-'J682 FAX 777·6462 FAX.771-5616 FA"X171·5973

(307)7n-71S6 (307) 171·1152. (07) 777-77&1 FAX777-"5864 PAX 777:S973 FAX 717--5')73

Page 54: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Please reference Application No. 13-116 in any future correspondence.

If you have any questions, please contact me at either [email protected] or by phone at (307) 777-7088.

Sincerely,

$fl.J.~~ Seth Tourney, P.E. Southeast District Engineer Water Quality Division

SWT/nnf13-0473

Enclosures: Certificate of Completion form

co: IPS C. Jade Gernant, DOWL ID<M, 1575 N0l1h 4th Street, Suite l{)S, Laramie, Wyoming 82072 Cal Van Zee, City of Laramie, P.O. Box C, Laramie, Wyoming 82072

1 , I

( ;

. :

(

Page 55: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality

To protect, conserve and enhance the quality of Wyoming's environment for the benefit of current and future generations.

Matt Melld, Governor Todd Parfitt, Director

NOTIFICATION OF COVERAGE April 22, 2013

Ron Granger, Vice President for Administrative Services Central Wyoming College 2660 Peck Ave. Riverton, WY 82501

RE: CWC Pro-Tech Remodel and Addition DEQ Permit #13-117 Located in. Fremont County, NE %, SE %, S29, TiN, R4E

Dear Mr. Granger,

This project consists of the addition of a 4 Inch PVC fire supply line, the replacement of 8 inch vitrified clay sewer pipe with schedule 40 PVC pipe, and the addition of a 4 inch schedule 40 PVC sewer service.

The above application for coverage under General Pennit has been reviewed In accordance with Chapter 3, Section 7; Chapter 11 and Chapter 12 of the Wyoming Water Quality Rules and Regulations and Is hereby approved.

You are authorized to construct, the facility in accordance with the general permit and the materials submitted In your application package, and the General Permit to Construct, Install, Modify or Operate Extensions to or Modification to Existing Public Waler Supply Distribution Systems and tlhe Genenal Permit to Construct, Install, Modify or Operate Extensions to or Modification of EXisting Sewage Collection Systems. Your atlention is directed to the mandatory reporting requirements outlined· In Part V, Section 0 of the general permit. Construction shall be completed by October 31, 2013

Your attention is directed to the atlached Certificate of Completion form, which is to be submitted within 60 days of the completion altha aforementioned project.

These General Permit requirements can be downloaded from the Wyoming Department of Environmental Quality webpage. The General Permits can be found under the Water Quality Division Water and Wastewater Program, Engineering and Technical Services at:

http://deq.state.wy.us/wgd/www/Permllling/Pages/general permlts.asp

If you have any questions, please contact Hannes Stueckler at 307-335-6964 or James Brough at 307-335-6961. .

annes E. Stueckler, P.E. Assistant Northwest District Engineer Waler Quality Division

xc: PDF to Cheyenne Jeff Young, Trlhydro Corporation, 350 Garfield, Lander, WY 82520

Lander Field Office • 510 Meadowview Drive • Lander, WY 82520 • http://deq.state.wy_us ABANOONED MINES

(307) 332-6085 FAX 332-7726

AIR QUALITY (307) 332-6766 "FAX 332-7726

LAND QUALITY (307) 332-3047 FAX 332-7726

SOLID & HAz:AROOUS WASTE (307) 332-5924 FAX 332-7726

WATgR QUALITY (307) 332-3144 FAX 332-7726 • -

Page 56: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

( !

(

Page 57: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality To protect, conselV9, and enhance the quality of l1YOmings

environment lor the benem of cutrem and future genflJ1Jllons.

Matthew H, Mead, Governor 152 N. Durbin St., Suite 100 • Casper, WY 82601 • (307) 473-3450

April 12, 2013

Andrew Beamer, P.E. City of Casper 200 North David Street Casper, WY 82601

NOTIFICATION OF COVERAGE

RE: Casper Streets - 2013 Miscellaneous Sanitary Sewer Lining Application No. 13-118, Natrona Couaty

Dear Mr. Beamer:

Todd Parfitt, Dlr.Clo,

The above application for coverage lUlder General Permit to Construct, Install, Modify or Operate Extensions to or Modifications ofEristing Sewage Collection Systems, consisting of the the lining of 6,300 feet of sanitary sewer located in Section 9, Township 33N, Range 79W, Natrona County, in accordance with Chapter 3, Section 9 of the Wyoming Water Quality Rules and Regulations has been reviewed and is hereby approved. YOII are authorized to oonstruct, install, or modify the facility in accordanoe with Chapter 11 of the Water Quality Division Rules and Regulations, the general permit, and the materials submitted in your application package. Your attention is directed to the mandatory reporting requirements outlined in Part V, Section 0 of the general permit. All construction, installation, or moclification allowed by this Notification of Coverage shall be completed by December 31, 2014.

This Notification of Coverage is covered UIld,er the General Permits on the Wyoming Department of Environmental Quality webpage:

http://deq.state.wy.us/wqd/www/PermittingiPages/general permits.asp

IfyOli have allY questions, please contact me at307-473-3469.

Sincerely, z/ /,-"-;:.j,v--r . ".;/ ,

/ Jason Vreeland, P.E. Assistant NE District Engineer WDEQlWQD

cc: IPS, Cheyenne WDEQ Casper File Alex Sveda, P .E., City of Casper, 200 N. David Street, Casper, WY 8260 I

Cheloone 122 West 25 Street 82002

(307) 777-7937

Lander 'SIO Meadowview Drive 82520

(307) 332-3144

Sheridan 2100 W. 5" Street 82801

(307) 673-9337

Page 58: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(

(

Page 59: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

STATE OF WYOMING DEPARTMENT OF ENVIRONMENTAL QUALITY

UNDERGROUND INJECTION CONTROL PERMIT ISSUED UNDER WYOMING WATER QUALITY RULES AND REGULATIONS

CHAPTER 16

CLASS V INJECTION WELL

( ) New ( ) Modified (X) Renewal

Permit Number: 13-119 Facility Number: WYS-039-033 State Subclass: 5E3

In compliance with the Wyoming Environmental Quality act (W.S. 35-11-101 through 1104, specifically 301(a)(i) through 301 (a)(iv), Laws 1973, Ch. 250, Section 1) and Wyoming Water Quality Rules and Regulations, Chapter 16.

Applicant: Flat Creek Motel 1935NHwy 89 Jackson, WY 83002

Flat Creek Motel, hereafter referred to as the permittee, is authorized to operate the septic system located in the NEY. of the NWY. of Section 22, Township 41 North, Range 116 West, of the 6th

Principal Meridian, Teton County, WY. The permittee is allowed to operate the facility according to the procedures and conditions of application 13-119, and requirements and other conditions of this permit.

This permit shall become effective on the date of issuance and is valid for ten (10) years.

Kevin Frederick, Administrator Water Quality Division Herschler Building, 122 West 25th Street Cheyenne, WY 82002 (307)-777-7781

d Parfitt, Director epartment of Enviro ntal Quality

Herschler Building, 122 West 25th Street Cheyenne, WY 82002

CMc/rm/13-0610

PERMIT 13-119 Final July 2, 2013

7 - t/ - 12 Date

IDa

Page 1 of 11

Page 60: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Table of Contents

A. Discharge'Zone .......... , .. ~ .... ' ... :: .......................... : .. , ... : ........................................................ 3

B. Well and Area of Review ............................................................................................... .3

C. Groundwater Classification ............................................................................................. 3

D. Authorized Op()ratidns.: ........... :.: ..................................................................................... 3

E. Hazardous Waste ; ....... , .................................................................................................... 4

F. 'Proper Operation and Maintenance .; ..................... ' ..... :; ... ;' .... ;.:;: .. ; .. : ............................... .4 ".

G. Entry and Inspection ........................................................................................................ 4

H. Environmental Monitoring Program for Groundwaters oftheState .............................. .4

1. Requirements for Monitoring Groundwaters of the State .c ............................................. 7

J. . Test Procedures ........................ ;;: .............................. ; .• : .. .'.:' ......... : ..................................... 8

K. . Records andReports .................................. ; .... · ................................... .' ............................. 8

L. Permit Actions ................................................................................................................. 8

M. Abandonment. ................................................................................................................... 9 \

N. "1 .' i.' '

Duties of the Permittee ............................................................. ;;::· ..... :.1 .• , .. : ...................... 9

O. Signatories Requirement. ........................................................................ ; ........................ 9

P. Noncompliance .................................................................................... ; ............ : ............ 1 0

Q. Permit Transfer ....................................................... , ....................................................... 10

R. .Property Rights .......................................................... : ...... ;;;;;':.' ................ : ... ; ........... ; .... 11

S. Severability ............................................................. ; ...... : .................... ; .......................... 11·,

Page 2 of 11 PERMIl13·119 Final July 2,2013

(

(

(,

Page 61: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

A. Discharge Zone This injection facility (sanitary leachfield) is authorized to inject 4,500 gallons per day average and 7,500 gallons per day maximum. The primary treated wastewater is injected into the unconfined alluvial aquifer. Depth to groundwater in the vicinity of the leachfield is approximately ten (10) feet, based on test borings dug near the points of injection.

B. Well and Area of Review The injection well authorized by this permit is located as follows:

NEY> of the NW Y> of Section 22. Township 41 North, Range 116 West, of the 6th Principal Meridian, Teton County

The Area of Review is defined as a circular area of 360 acres with the injection facility located near its center.

The Area of Review is based upon the following information:

C. Groundwater Classification The grmmdwater in the alluvial aquifer beneath the permittee's property is classified as Class I by quality according to Wyoming Water Quality Rules and Regulations, Chapter 8, Table 1. This classification is made because the groundwater in this formation is currently being used for domestic purposes at nearby points of withdrawal.

Groundwater of Class I shall not be degraded to make it unusable as a source of water for this purpose. An aquifer that contains less than 10,000 mgIL total dissolved solids (and is not exempted) can be considered an underground source of drinking water.

D. Authorized Operations

The operator is authorized to inject at a pressure of no more than atmospheric pressure as measured at the leach field. This pressure is controlled by gravity drainage and is not required to be monitored. The permittee is authorized to inject a maximmn of 7,500 gallons per day. The wastewater is produced from a 75-room motel, and a gas station. A proposed future sandwich shop and employee housing may be added to the system at a future time, and the above rate is inclusive of those additional sewage flows. The wastewater is inj ected into the unconfined alluvial aquifer. The wastewater is described as primary treated domestic sewage from a septic tanle

PERMIT 13-1J9 Final July 2, 2013

Page 3 of 11

Page 62: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

If additional sewage flows are added beyond those identified in the permit application, the leach· field and/or treatment system may ne.ed to be enlarged inwhichcase the permittee must submit a ( revised application and receive a new permit prior to modification of the leach field or treatment· system

E. Hazardous Waste This permit does not allow for the injection of any hazardous waste as.defmed in 40 CFR 261.3 . and in Wyoming Solid Waste Management Rules and Regulations, Chapter 2. Injection of any substance defined as a hazardous waste, whether hazardous by listing or by characteristic is a violatiop. of this perinit. .; ..

F. Proper Oper:ltion and Maintenance The permittee sh~lltake alIreilsonable steps to minimize or correct any adverse impact on the environment res!llting from noncompliance with this .permit. The permittee shall operate and maintain all facilities and systems of treatment and control which· are installed or used by the permittee to achieve compliance with the conditions of the permit. Proper·operation and maintenance includes: effective performance, adequate funding,6perator staffing and training, and laboratory and processcolltr(}ls,in;cludingap.wopriat~qualif)ra~surancellroGedures. This provision requiresthe·9Ptjrajion. ofba(;k~up. oraUJ{i)iaryfaG~lities.orsimilarsystems only when necessary to achievecompliancewith the conditions .ofthis permit.. The injection wells covered by this perinit shall meet all constrnction requirements outlined in WYOIning Water Quality R!lles and Regulations, Chapters II, 16 and 25.

The permittee isreqwed to operate in accordance with statelJl.ents, representations and ( procedures presented in the complete pennit application and supporting documents as accepted and approved by the Administrator. Aoy modifications which will res!llt in a violation of perinit conditions shall be reported by submission of a new or amended permit application and shall not be implementec\;uutil a new ormodifi~dpennit has been .issueq. Injectloninto awell may not begin untilconstructioI\iscompleteand the perinit is appro"ed. .. . . .

G .. Entry a~d Inspe~tion The permittee shall allow the Aclministrator (upon presentation of credentials and during normal working hours) to .enter the.pn;miseswhere aregulated fa<:i1ity ~slocakd,orwhererycords are kept under the conditions of this permit and inspect and photograplJ.:tl!.e disc,harge and related facilities, review and copy reports and records required by this pennit,collect fluid samples for analysis, measure and record water levels, and perform any other function authorized by law or regulation.

, '-" ,

H. E .. nvirollmental Monitoring Program for Groundwatersof the State , -', >- . ' " ;'.' , ' ' - -.

General Requirements:

1. Samples ane! measurements taken for the purpose of monitoring shall be r~presentative of the monitored activity. A groundwater sample is considered representative of the aquifer being monitored when the well has been purged to remove stagnant water prior to collection of a sample for laboratory analysis. Purging can be considered complete when a sufficient volume (. I

of water has been removed from the well and stabilization of select groundwater parameters

PERMIT 13·119 Final July 2, 2013

·.Page 4 0fll·

Page 63: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

has been achieved. It is important to record the circumstances surrounding each sample collection event at your facility. These records can help resolve analytical discrepancies. One or both purging methods below shall be used prior to sample collection:

a. Purge by Volume Method Removal of a minimum of three casing volumes of water from the well should be completed prior to collecting a groundwater sample. Minimum purge volume can be calculated by the following equation:

Minimum Purge Volume = 3 * «Total Well Depth in feet - Depth to Water in feet) * Well Capacity) Where Well Capacity (gallons per foot) is based on well diameter:

2 inch well = 0.163 6 inch well = 1.47 4 inch well = 0.653 8 inch well = 2.61

b. Stabilization of Parameters Method Purging of groundwater until select field parameters have stabilized can be used to demonstrate that a representative sample was collected. Field parameters measured during purging should include at a minimum temperature, pH, and specific conductance. Field parameters should be measured after removal of every half casing volume of water.

Half Casing Volume = 0.5 * «Total Well Depth in feet - Depth to Water in feet) * Well Capacity)

Where Well Capacity (gallons per foot) is based on well diameter: 2 inch well = 0.163 6 inch well = 1.47 4 inch well = 0.653 8 inch well = 2.61

A minimum of six (6) parameter measurements should be collected. If field parameters have not stabilized between the last three readings, purging and parameter measurement should continue until stabilization has been achieved. Stabilization can be demonstrated by a variance of no more than +/- 10% for temperature and specific conductance, and +/-0.2 standard units for pH.

2. The permittee shall retain records of all monitoring information including all calibration and maintenance records, copies of the reports required by this permit, and records of all data used to complete the application for this permit, for a period of at least three (3) years from the date of the sample measurement, report, or application. This period may be extended by request of the Administrator at any time.

3. The permittee shall use electronic data deliverable (EDD) reporting when required by the Administrator.

4. Records of monitoring information shall include:

a. The date, exact place, and time of sampling or measurements;

PERMIT 13-119 Final July 2, 2013

Page 5 of) 1

Page 64: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

b. The" initials or name(s)" of the individual(s) who performed the sampling or measurements;

c. The date(s) analyseswere performed; d. The time(s) analyses were initiated; e. The initials or name(s) of the individual(s) who performed the analyses; f. References and writt~n proceduresfor the analytical techniq~es or methods used; g. Thetesults of such analyses, inClUding the bench sheetS, instrument readouts, computer

disks or tapes, etc., used to determine these results.' .

5. Monitoring mus~ be cond~cted accotdingto test proc~aUr~s appro~ed under 40 CFR Part 136, unless othettest procedures have been specified inlhispermit.'·,

6. The permittee shall retain all records conceming. the natUre and composition of injected fluids until five (5) years after completion of any specified plugging and abandonment procedures. The administrator may require the owner/operator to deliver the records to the administrator at the conclusion of the retention period .• ,

7. The permittee shall report any '. noncompliance which may endanger health or the environment Within twerity-four(24) hours from the time the operator becomes aware of the circumstances. The report should indude:

(

a. Any monitoring or other information .which indicates that any contaminant may cause an endangerment tei a usable groundwater of the state;

b. Any noncompliance with a permit condition or malfunction of·the discharge (injection) ( system which may cause fluid migration into or between usable ground waters of the state;

c. A written submission shall be provided within five (5) days of the time the operator becomes aware of the circumstances. This writteri SUbmission shall contain a description of then6ncompliance andjtscause; the period of noncomp1i<,ilice, mcluding exact dates and times, and if thenohcompliance has not been corrected, ithe anticipat~d time it is expected to continue; arid steps taken or planned to reduce, eliminate; and prevent reoccurrence ofthe noncompliance.

8. The permittee shall report all instances of noncompliance not reported otherwise, at the time monitoring reports are submitted:

9. The monitoring reports shall be submitted on forms provided by the Department. Reports of compliance or noncompliance with, or any progress reports on, interim and final requirements contained in any compliance schedule of this permit shall be submitted no later than forty-five (45) days following each schedule date.

10. The permittee's supply well (P76783W) which is upgradient of the leachfields, shall be sampled once to obtain baseline data. The· parameters to be analyzed will be Nitrate, Annnonia as N, Chloride, pH and Total Coliform.

PERMIT 13-119 Final July 2,2013

Page 6 of 11

(I

Page 65: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

I. Requirements for Monitoring Groundwaters of the State

The groundwater in the receiving formation shall be sampled and the following parameters analyzed according to the schedule identified in Table 2. The following parameters shall be analyzed semi-annually and reported annually:

MW-I19 and Nitrate-Nitrite as N

MW-120 Semi-Annually Chloride

300.0; 300.1; or 4110 B, 4140 B, or 250mglL I :L.?S days / no

Monitor wells, (January-June and 353.2 4500-Cl downgradient of July-December)

pH (standard units; s.u.) 150.1 or 150.2 4500-H+B 6.5-8.5 s.n. I measure as soon as leachfield

T'\",~i-"h +,.,. ,,+ .... ~ .... n' ..... +-"' ...

Steel tape N/A N/A

Flow meter reading 7,500 gpd N/A Septic Tanksr

Aunually I Sludge d~~~ in tanks I Visnal 2 feet N/A

NOTES: * All applicable chemical concentrations in this permit are expressed as total (not dissolved) in mglL uuless otherwise noted.

1 The septic tanks serving the Flat Creek Motel are to be inspected, at a minimum, annually and must be pumped as necessary based on sludge depth at bottom ofthe septic tallie, and at least once every five (5) years. A copy of the invoice for pumping the tanks is to be included with the annual report. Sludge depth is not to exceed 24 inches in the septic tanks.

All annual reports are to be reported within forty-five (45) days of the last day of each year (February 15th).

The above upper control limits (DCL) cannot be exceeded in any sample. Exceedance of these values is a violation of this permit and shall require notification under Section K of this permit. If the DCL is exceeded in a sample, additional monitoring wells may be required to determine whether groundwater has been impacted and to delineate the nature and extent of any contamination resulting from operation of the permitted facility.

PERMIT 13-119 Final July 2, 2013

Page 7 of 11

Page 66: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

J. Test Procedures All samples and ~easurements taken for the pnrpose. (jf monitoring shall be. representative of the monitored activity.- All samples taken shall include a trip blallk of distilled. water for each sampling date and a duplicate sample at least once per year. All requireddmalyses shall be conducted in compliance with Wyoming Water Quality Ru1es and Regul\ltions, Chapter 8, Section 7.

K. Records and R~ports ..; . The permitteeshaltfurnishtothe.Administrator within a specifi~cl time any)D:formation which the Administratormayr(,)quest #,lating to the operation of thefacility,jncluding copies of records required .fol}e kept by this permit The permittee shall retain copiesofall records and reports required by this permit for a period of three (3) Years follo~g.permanent well abandonment-After thattime,thoserecoidsshall be delivered to the Administrator for disposal or archive at.his ;discretion. Confrrmednoncompliance resulting in themigr~tion of injected fluid into any zone outside thepermittedreceiver shall be reported to theA~!pinistrator within twenty-four (24) hours, and a written submission (via certified.I)'l~I) shilll.b"ePtovided within five (5) days of the time the permittee becomes aWare oftheexbtirsion.Tl;le:~tten submission shall contain:\ldescription offhe noncompliance; the period of nOll(;ompli®c~iiiIcluding exact dates and times,and if the noncompliarlCe has notbeencontrolled, the flllticiPllted time it is expected to continue; and a list of the steps taken or plarmed to reduce, elimiIlate,and prevent the recurrence of the nbncompliance.·Confrrmed noncompliance 'not already Jeported under this section shall be reported at the time monitoring reports are submitted. The r.~p(jrts shall contain the same information as required ty the paragraph above .... Thepermittef.shall. notify the Administratorthirty (30) days in advance of any plarmed alteration, con~eisi~n,6r abandonment of the well covered by this permit.

L. Permit Actions This permit is authorized for. a period of ten (10) years. If the permitteewi~hes to continue injection afterthe expiration date of this permit he shall apply to the Administrator and obtain a new permit. The. application shou1d be submitted at least 180 days before the~xpiration date of this permit. Underthis permit, tllepepartrnent may consider.injection after the expiration date a violation of the p¢lrmit.· ~. .

It shall not be a defense for the pe~ittee in an enforcement action that it would be necessary to halt or reduce the permitted activi1:)iin order to maintain compliance with the conditions of the permit. The fi,lingof a tequestbythe permittee, or at the instigation of the Administrator, for permit modificatioIl, revocation, termination, or notification of planned changes or anticipated noncompliance shall not stay .anycondition of this permit.

After notice and. opportunity for a hearing, a permit may be modified, suspended or revoked in whole or part during its term for cause which includes, but is not limited to any of the following:

1. Violation of this permit; or. 2. Obtaining a permit by misrepresentation of facts in the application.

PERMIT 13-119 Final July 2, 2013

Page 80fll , .'''-.

(

(

(

Page 67: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

This permit will be reviewed at least once every five (5) years, and may be reviewed more frequently. A permit may be modified at any time as may be required, including for conformity with changes in regulations or standards which occur after the permit was issued. A permit may be modified in whole or part in order to apply more or less stringent standards; or prohibitions for toxic or other substances present in the pemlittees discharge as may be ordered by the Enviromnental Quality Council.

M. Abandonment General Requirements:

1. The permittee shall notify the administrator at least thirty (30) days prior to abandomnent of the facility.

2. An abandomnent report, detailing the compliance with abandomnent procedures outlined in the original application for coverage under this permit, or describing any deviations from the original plan, shall be submitted as soon as practicable after abandomnent. The abandomnent shall include reclamation of the well site.

3. Injection wells covered by this permit shall be abandoned in accordance with Wyoming Water Quality Rules and Regulations, Chapter 16, Section 12.

N. Duties of the Permittee The permittee shall give advance notice to the Administrator as soon as possible of any planned physical alteration or additions, other than authorized operation and maintenance, to the permitted facility and receive authorization prior to implementing the proposed alteration or addition. The permittee shall furnish the Administrator within a reasonable time any information which the Administrator may request to determine whether cause exists for modifying, revoking, or reissuing, or terminating this permit, or to determine compliance with this permit; and to furnish to the Administrator upon request, copies of records required to be kept by this permit. Any modification which may result in a violation of a permit condition shall be reported to the Administrator, and any modification that will result in a violation of any permit conditions shall be reported to the Administrator through the submission of a new or amended permit application. The permittee shall report all instances where he becomes aware that he failed to submit any relevant facts in the permit application, or where he submitted incorrect information in a permit application or in any report to the Administrator, and shall promptly submit such facts or information.

If any cultural materials are discovered during construction, work in the area should. halt immediately. The Administrator and the Wyoming State Historic Preservation Office shall be contacted (777-7697) and the materials shall be evaluated by an archaeologist or historian meeting the Secretary of the Interior's Professional Qualification Standards (48 FR 22716, Sept. 1983).

O. Signatories Requirement All reports filed in conjunction with this permit shall contain the following certification:

"I certify, under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel

PERMIT 13·119 Final July 2, 2013

Page 90f 11

Page 68: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

properly gather and evaluate theinformationsubmitted.' Based on myinquiry of the person or (~ , persons who manage the system, or those persons directly responsible for gathering the • infoimation, the infomiation submitted is to the best of my knowledge and belief, true, accurate, . and complete .. I am aware that there are significantpenalties for submitting false information, including the possibility offine and imprisonment for knowing violations."

All reports required by this permit and other requested information shall be signed as follows: ~

For a cOrPoration - by a principal executive officer of at least the level ofvicecpresident;

For a partnership or sole proprietorship "":by a general partner or the proprietor, respectively;

For a municipality, state, federal, or other public agency ~by either a principal executive officer orraiJkingelected official; or •. , .

By a duly authorized representative for any of the above. A person is a duly authorized representative only if:

1. The authorization is made in writing by one of the prescribed principals; 2. The authorization specifies either an individual or position having' responsibility for the

overall operation ofthe regulated facility or activity; and 3. The written authorization is submitted to the Admimstrator.

If an authorization. is . no longer accuratt! because a different individual, or position has ( ; responsibility for the overall operation of the facility, a new authorization must be submitted to the Administrator prior to or together with any reports or. information; to be signed by the new authorized representative. '

P .,N oncompliance, The permittee shalL comply with all conditions of the permit. Anyperinit noncompliance constitutes a violation' of Wyoming' Water Quality Rules and Regulations, Chapter 16 and, is grounds for enforcement action, permittermination, revocation, or modification. Conformed noncompliance resulting in an 'excursion shall be reported to the Administrator orally within twenty-four (24) hours, and a written submission shall be provided within five (5) days of the time the permittee becomes aware of the excursion. The written report shall contain the sections specified in Section K of this permit. Any permit noncompliance constitutes a violation of this permit.

The filing of any request by the permittee for a permit modification, revocation and reissuance, or termination, or a notification of planned changes or anticipated noncompliance, does not stay any permit condition.

Q. Permit Tr;msfer Any transfer of this permit shall be accomplished by the submission of the proper forms for permit transfer to the Administrator. . Transfer of this permit must first be approved by the (~ Administrator and the Director. N o transfer shall be approved unless the proposed permittee

PERMIT 13-119 Final July 2,2013

Page 10 of11

Page 69: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

agrees to bring any and all noncompliance issues into compliance with this permit. The permittee is alone responsible for the operation of the facility covered by this permit. Sale of the facility and subsequent operation of this facility by another is a violation of this permit unless a transfer of this permit has first been accomplished.

R. Property Rights

This permit does not convey any property rights of any sort or any exclusive privilege. This permit does not authorize injury to private property or any invasion of personal rights, nor any infringement of federal, state, or local laws or regulations.

S. Severability

Nothing in this permit shall be construed to preclude the institution of any legal action or to relieve the permittee from any responsibilities, liabilities, or penalties established pursuant to any applicable state law or regulation.

PERMIT 13-119 Final July 2, 2013

-End oCPermit-

Page 11 of 11

Page 70: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(

(

Page 71: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality

To protect, conserve and enhance the quality of Wyoming's

environment for the benefit of current and future generations.

Matthew H. Mead~ Governor Todd Parfitt, Director

July 3, 2013

Leon Nelson 1409N.400W American Fork, UT 84003

RE: Flat Creek Motel Final Permit 13-119, Class V Septic System Renewal Teton County, Wyoming

Dear Mr. Nelson:

Attached please find one copy of the Class V septic system permit for the facility referenced above. This permit requires annual inspection and periodic pumping of the septic tanks, semi-annual sampling of the downgradient monitoring wells (MW-119 and MW-120) and a one-time baseline sample of the upgradient supply well (P76783W). The corresponding report forms can be filled out usiug our on-line webform (Monitor Reports Link), or you may have the lab submit them using 'Report Data Loader' link at the following site: http:// gem.wq d.apps.deq. wyoming. gov.

For your convenience, the Wyoming Department of Enviromnental Quality (WDEQ) has printed the inspection forms and enclosed them in this mailing, you may use the paper forms to report your inspection and monitoring activities to WDEQ. Please use the exact well names used in your permit when reporting data to avoid any miscommunications.

The underground injection control program was promulgated to prevent serious problems caused by direct discharges to the groundwater. Those problems included groundwater pollution leading to contamination in domestic water wells and serious health effects caused by exposures to toxic substances and water borne pathogens. Your cooperation with our program is sincerely appreciated.

If you have any questions please do not hesitate to contact me at the below referenced phone number or email.

Sincerely,

Carol McAdams, GIT Wyoming Department of Environmental Quality Water Quality Division (307) 777-2960 [email protected] CMc/rm/13-06l0

Enclosure: Final Permit # 13-119 Monitoring Report Forms

cc: John Passehl, WDEQ .-------------------------~'"'----

Hersch!er Building' 122 West 25th Street· Cheyenne, WY 82002 . http://deq.state.wy.us ADMIN/OUTREACH ABANDONED MINES AIR QUALITY INDUSTRIAL SITING

(307) 777-7758 (307) 771-6145 (307) 777-7391 (307) 777-7369 FAX 777-7682 FAX 777-6462 FAX777-5616 FAX 777-5973

LAND QUALITY SOLID & HAZ, WASTE (307)777-7756 (307)777-7752 FAX 777-5864 FAX 777-5973

WATER QUALITY (307) 777-7781 FAX 777-5973

eli . . ~ . 7

c -

Page 72: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(

Page 73: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

PERMIT NO. 13-120

WYOMING DEPARTMENT OF ENVIRONMENTAL QUALITY WATER QUALITY DIVISION

PERMIT TO CONSTRUCT

REFERENCE PERMIT NO. NI A

C61liiisHeights Lift Stillion Upgfaoe

This permit hereby authorizes the applicant:

Steve Peterson. P .E. City of Gillette

611 N. Exchange Avenue Gillette. WY 82717

to construct, install or modifY the Collins Heights Lift Station according to the procedures and conditions of the application number 13-120. The facility is located in the NE Y. of Section 30, Township 50 North, Range 71 West, further located iu Gillette, Wyoming. All construction, installation, or modification allowed by this permit shall be completed by December 31,2015.

The issuance of this permit confirms that the Wyoming Department of Environmental Quality (DEQ) has evaluated the application submitted by the permittee and determined that it meets minimum applicable construction and design standards. The compliance with construction standards and the operation and maintenance of the facility to meet the engineer's design are the responsibility of the permittee, owner, and operator.

Granting this permit does not imply that DEQ guarantees or ensures that the permitted facility, when constructed, will meet applicable permit conditions or other operational requirements. Compliance with all applicable standards remains the responsibility of the permittee.

Nothing in tms permit constitutes an endorsement by DEQ of the construction or the design of the facility described herein. This permit verifies only that the submitted application meets the design and construction standards imposed by Wyoming statutes, rules and regulations. The DEQ assumes no liability for, and does not in any way guarantee or warrant the performance or operation of the permitted facility. The permittee, owner and operator are solely responsible for any liability arising from the construction or operation of the permitted facility. By issuing this permit, the State of Wyoming does not waive its sovereign immunity.

, \-.

The permittee shall allow authorized representatives from DEQ to enter and inspect 88)1, "p,operty, 'pxemi,se or place on or at which the facility is located or is being constructed or installed for the purpose of investigating actual or potential sources of water pollution, and for determining compliance or non-compliance with any rules, regulations, standards, permits or orders,

Nothing in this permit shall be construed to preclude the institution of any legal action or other proceeding to enforce any applicable provision of law or rules and regulations. It is the duty of the permittee, owner and operator to comply with all applicable federal, state and local laws or regulations in the exercise of its activities authorized by tms permit The issuance of this permit does not convey any properly rights in either real or personal property or any invasion of personal rights, nor any infringement of federal, state or local laws or regulations.

The permittee shall construct and operate the permitted facility in accordance with the statements, representations, procedures, terms and conditions of the permit application, supporting documents and permit. This permit does not relieve the permittee from any duty to obtaiu any other permit or authorization that may be required by any provision offederal, state or local laws,

Page 74: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

In carrying out its activities authorized bY;~iSP~Au'it,' the'perhtitree, Owner and ()perator shall comply with all of the followiug permit couditions: . . .' ..... . , .;' .. ,. . . (

10f4

20f4

'I'IiS ,aRplicat.ltwill prOvide immediate oralor written notice tothe NortheaStDistrict, Water QualityDi~isioh;152 North Durbin; Suite 100, Casper, WY, 82601, Pl1one307~473-3465; ,FA::x 307-473~3458: inaccor~ance~itl1t11eprovisionsof SeCtion .. 1 t,Chapter 3,Wyoming 'vV~ter Quality Rulesand Regulations of aiiychan'gesorlriodifications which are not consistent withthe teims and conclitionsof ihispermit.

. . . - . ,~.

Within sixty days ofcompletiOl).of,constfpcti?n" of the au1:h~rized fa?ility, the applicant will submit to theNortheast Distdc(W~ter;Q?~litybivision, 152l'<~ithDurbiri, Suite 100, Casper, WYi82601acertificati~n,ofco]tiJllei.i(jJ1sig'n~d by t~eEngineer of Record or the owner. A form titled "Certificate of Completioli"'hasb~enp~dviciecl/'

. ,,"' ,- -,,'"j;.<";'('- ,', ':"'-:-::\\j/',:-~?'j/-" .

a. Datethatcoiistruction of the facilitY,'wascompleted; and '

~'at~~~tthefaCility~a~PI~cediii o~~riiiin; ~ri~',;l:{'·'/···' . "r<\;'-\.', ;;; _" - . ~,,--., .' _"",;" ;,-

c. Certification the facility was constructed in accoiclancewiththe terms and conditions of the permit; or .. ' ... "" .. ,'

d.

30f4

". Cemfic~tiol1thefacility\vasconipleted\vithcha1gesorfuo,dificati()ns. Submittal of as­'coJ1struct.;d plailsandspecifications forahe. systema~ i~' ",as constructed, certified by an engineer if appr6\Jriate is required. Allmodificat'ions or dilViations from the authorized plans mustbe highlighted.

Within thirty days of c!lInpleti()n'()f constructi()nofthea?th~rit!bd1'acility; the Engineer of Record ( will subnlit two (2)compJetecopiesofthe OperatiqnandMainfeTIll11ce Manuals to the Northeast District, Water Quality Division, 152 North Durbin;Suite'l OO;Casper,'WY 82601.

40f4 Therevie", an~approvalof this peimit is based upon the it~ins ideiitified in the attached , "Statement oI'Basis". . . . ' . .

A.UTHORIzED BY:

~l Kevin Frederick' Administrator Water Quality Division

Date ofIssuailce

TP/KF IJRV /bbl13-0394

To&t Parfitt . . . Director"· Department of EnvirOtl1nental Quality

cc: Dayton Alsaker, P.E., DOWL HKM, 16 W. 8th Street, Sheridan, WY 82801

()

Page 75: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

STATEMENT OF BASIS

1. Permit Number: 13-120

2. Application reviewed for compliance with the following applicable regulations:

CHAPTER 3 AND CHAPTERll OF THE WYOMING WATER QUALITY RULES AND REGULATIONS

3. Does the permit comply with all applicable regulations identified above?

YES

4. Facilities include components not specifically covered or differing from applicable regulations and approval is based upon a deviation in accordance with Section 5.

N/A

5. A review to determine groundwater impacts in accordance with Section 17, Chapter 3 is not required.

6. Documentation of Statement of Basis: The archive file for this permit includes adequate documentation of all sections of this Statement of Basis.

CERTIFICATION

The issuance of this permit is based upon a review of the application package submitted in accordance with the requirements of Chapter 3, Section 6, Wyoming Water Quality Rules and Regulations. This review was performed by Jason Vreeland, P.E., and completed on May 1,2013. Permit issuance is recommended based upon statements, representations, and procedures presented in the permit application and supporting documents, permit conditions, and the items identified in this "Statement of Basis."

JRV/bb/13-0394

Page 76: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(

()

Page 77: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality To protect, conserve, and enhance the quality of Wyoming's

environment for the benefft of current and future generations.

Matthew H. Mead. Governor 152 N. Durbin St., Suite 100 . Casper, WY 82601 . (307) 473-3450

April 16, 2013

Dayton Alsaker, P.E. DOWLHKM 16 W. 8th Street Sheridan, WY 82801

RE: Collins Heights Lift Station Upgrade Location: NE \4, Section 30, T. SON, R. 71 W, Gillette, WY WDEQ Application #13-120

Dear Mr. Alsaker:

Todd Parfitt. Director

We have completed our review of the permit application submitted on March 28, 2013. Attached you will find a summary of the review comments. Please provide the information requested as soon as possible. Please feel free to contact me at (307) 473-3469 should you have any questions related to these comments or the application and review process.

Sincerely,

"r","":;? '7 --'"? /" // C c,,,,-,,

Jason Vreeland, P.E. Assistant Northeast District Engineer WDEQ/WQD

Attachments: WDEQ Comments

cc: IPS WDEQ File

Chel;'enne 122 West 251 Street 82002

(307) 777·7937

Lander 510 Meadowview Drive 82520

(307) 332·3144

Sheridan 2100 W. 5th Street 82801

(307) 673·9337

Page 78: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(,

( )

Page 79: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

REVIEW OF PLANS & SPECIFICATIONS WYOMING DEPARTMENT OF ENVIRONMENTAL QUALITY

WATER QUALITY DIVISION 152 North Durbin Street, Suite 100

Casper, Wyoming 82601 Phone (307) 473-3465

PROJECT: Collins Heights Lift Station Upgrade

LOCATION: Gillette, Wyoming

ENGINEER: DOWLHKM

APPLICANT: City of Gillette

WATER QUALITY DIVISION APPLICATION NUMBER: 13-120

DATE ON PROPOSAL/PLANS/REPORT: March 27,2013

DATE RECEIVED BY DEQ: March 28,2013

DATE OF THIS REVIEW: April 16, 2013

WDEQ REVIEWER: Jason Vreeland, P.E.

ACTION: NOT AUTHORIZED FOR CONSTRUCTION. In accordance with Chapter 3, Section 14 (a), Wyoming Water Quality Rules and Regulations (WWQRR), the application is denied because it is incomplete and/or contains errors. Please address the comments outlined below and submit the requested information/clarifications in order that the application process may be completed in accordance with Chapter 3, Section 9 of the WWQRR. If the applicant fails to provide the requested information within six months, the incomplete application shall be returned. This review may not include all deficiencies and shall not be construed as a complete comprehensive list.

WDEQ COMMENTS

1) Chapter 11, Section 1 O(a)(i) - Please provide the calculations for the total dynamic head rating of the pumping units. Also, please provide the pump curves.

2) Chapter 11, Section 10(a)(v) - The design report indicates thatthe wet well was sized so that the number of pump starts does not exceed 6 per hour. The report indicated that one-half the design flow rate would correspond to the minimum pump cycle time. The minimum operating interval should correspond with the highest design flow. Further, the wet well must be able to contain this volume between the pump on and pump off levels. The wet well in the plan set does not appear to have sufficient capacity. Please address.

3) Chapter 11, Section 7(b)(ii) - Please label the profile with the type of PVC pipe to be used.

2

Page 80: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(;

(

Page 81: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

4) Chapter 11, Section 1 O( c )(ii) - The wet well walls are designed with a slope of 1: 1. WWQRR require hopper walls of wet wells to be sloped at no less than 1.75:1. Please address.

5) Chapter 11, Section 1 O(a)(i)(A) - The sump pump appears to be inaccessible upon installation ofthe piping. Please address access to the sump pump or comment on the accessibility of this pump.

3

Page 82: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(

(

Page 83: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

PERMIT NO. 13-121

WYOMING DEPARTMENT OF ENVIRONMENTAL QUALITY WATER QUALITY DIVISION

PERMIT TO CONSTRUCT

REFERENCE PERMIT NO. N/A

. Powder Horn Ranch Wastewater Treatfuent PhitifModificafions

This permit hereby authorizes the applicant:

Homer R. Scott Powder Horn Ranch LLC.

51 Powder Hom Road Sheridan. WY 8280 I

to construct, install or modify the Powder Horn Ranch wastewater treatment and sludge storage system according to the procedures and conditions of the application number 13-121. The facility is located in the SW \i, of Section 34, Township 55 North, Range 84 West, further located in Sheridan County, Wyoming. All construction, installation, or modification allowed by this permit shall be completed by December 31, 2014.

The issuance of this permit confirms that the Wyoming Department of Environmental Quality (DEQ) has evaluated the application submitted by the permittee and determined that it meets minimum applicable construction and design standards. The compliance with construction standards and the operation and maintenance of the facility to meet the engineer's design are the responsibility of the permittee, owner, and operator.

Granting this permit does not imply that DEQ guarantees or ensures that the permitted facility, when constructed, will meet applicable permit conditions or other operational requirements. Compliance with all applicable standards remains the responsibility of the pennittee.

Nothing in this permit constitutes an endorsement by DEQ of the construction or the design of the facility described herein. This pennit verifies only that the submitted application meets the design and construction standards imposed by Wyoming statutes, rules and regulations. The DEQ assumes no liability for, and does not in any way guarantee or warrant the performance or operation of the permitted facility. The permittee, owner and operator are solely responsible for any liability arising from the construction or operation ofthe pennitted facility. By issuing this permit, the State of Wyoming does not waive its sovereign immunity.

The permittee shall allow authorized representatives from DEQ to enter and inspect- any'-propertY, premise 'or place on or at which the facility is located or is being constructed or installed for the plrrpose of investigating actual or potential sources of water pollution, and for determining compliance or non-compliance with any rules, regulations, standards, permits or orders.

Nothing in this permit shall be construed to preclude the institution of any legal action or other proceeding to enforce any applicable provision of law or rules and regulations. It is the duty of the permittee, owner and operator to comply with all applicable federal, state and local laws or regulations in the exercise of its activities authorized by this permit. The issuance ofthis permit does not convey any property rights in either real or personal property or any invasion of personal rights, nor any infringement of federal, state or local laws or regulations.

The permittee shall construct and operate the pennitted facility in accordance with the statements, representations, procedures, terms and conditions of the permit application, supporting documents and pemlit. This permit does not relieve the permittee from any duty to obtain any other permit or authorization that may be required by any provision of federal, state or local laws.

Page 84: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

In carrying out its activities authorized by this permit, the permittee, oWner and operator shall comply with all of the following permit conditious: " , (

lof4

20f4

30f4

40f4

The applic~twin provide immediate oral or written notice totheNortiIeastDistrict, Water QualityDivision,152 North Durbin, Suite 100, Casper, WY, 82601, Phone 397~473-3465, FAX 307-473-3458, in accordance with the provisions of Section, 11, Chapter 3, Wyoming Water QualityRules andRegulations of any changes or modifications whicharenot consistent with the terms lUld conditions of this permit. '

Within sixtydays of completion of construction of th~ auth~rized f~cili~,the applicant will submit to th~ Northeast District, water Quaijty' ])ivision, 152 North Durbin, Snite 100, Casper, WY,82601 a certification of cpmpletionjigllectbYJ)1e Engineer of Record or the owner. A form titled "Certificate ofCompletion",Juis be'WproYi4ed. "

a. Date that construction ofthe facility wascompleted;and

b. 'Date thatthe facility was place4 in operation; and,

c.

d.

'" Certification thefacilitywas constrrictedin'lIccordance with the terms and conditions of the permit; or "

'" Certificationthti facility was comple~edwith changes or modifications. Submittal of as-. constructed plans and specifications for the system as itwas constructed, certified by an

: >engineerifappropriatejs,required. All modifications or deviations from the authorized plansnmst behighlighted.

Within thirty days of completion ofconstrriction of the auth()rizedfacility, the Engineer of, Record willsubinit two (2) complete copies of the Operation and Maintenance Manuals to the Northeast District, Water Quality Division, 152 North Durbin, Suite 100, Casper, WY 82601.

The review and approval of this permit is based upon the items identified in the attached "Statement of Basis". ."

Kevin Frederick Administrator

~~~. "lretr' , ' ,

Water Quality Division Department of Environmental Quality

Date of Issuance

JRV/rm/13-0345

cc: Travis Evans, P.E., ECS Engineers, 371 Coffeen Avenue, Sheridan, WY 82801

(

()

Page 85: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

STATEMENT OF BASIS

I. Penn it Number: 13-121

2. Application reviewed for compliance with the following applicable regulations:

CHAPTER 3 AND CHAPTER 11 OF THE WYOMING WATER QUALITY RULES AND REGULATIONS

3. Does the permit comply with all applicable regulations identified above?

YES

4. Facilities include components not specifically covered or differing from applicable regulations and approval is based upon a deviation in accordance with Section 5.

N/A

5. A review to detennine groundwater impacts in accordance with Section 17, Chapter 3 is not required.

6. Documentation of Statement of Basis: The archive file for this pennit includes adequate documentation of all sections of this Statement of Basis.

CERTIFICATION

The issuance of this pennit is based upon a review of the application package submitted in accordance with the requirements of Chapter 3, Section 6, Wyoming Water Quality Rules and Regulations. This review was perfonned by Jason Vreeland, P.E., and completed on April 19, 2013. Pennit issuance is recommended based upon statements, representations, and procedures presented in the permit application and supporting documents, permit conditions, and the items identified in this "Statement of Basis."

Page 86: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(

(

Page 87: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

PERMIT NO. 13-122

WYOMING DEPARTMENT OF ENVIRONMENTAL QUALITY WATER QUALITY DIVISION

PERMIT TO CONSTRUCT PWS No. WY5600136

REFERENCE PERMIT NO. 10-412 (RJ-7 Well)

. ------. '--'-WrightW aterand'Sewef'District""RJ~ 1W ell Completion,-Transmission;-and 'Primphouse- ...

This permit hereby authorizes the' applicant:

Joseph Johnson, Chairman Wright Water and Sewer District

P.O. Box 549 Wright. WY 82732

to construct, install or modifY a new pumphouse building, piping for the RJ-7 well site, approximately 17,000 lineal feet of raw and potable transmission lines, and components associated with the completion of the RJ-7 well, according to the procedures and conditions of the application number 13-122. The facility is located in Section 3 of Township 43 North, Range 72 West, Section 34 of Township 44 North, Range 72 West, and Section 35 of Township 44 North, Range 72 West, located in Campbell County, Wyoming. All construction, installation, or modification allowed by this permit shall be completed by December 31, 2015.

The issuance of this permit confirms that the Wyoming Department of Environmental Quality (DEQ) has evaluated the application submitted by the permittee and determined that it meets minimum applicable construction and design standards. The compliance with construction standards and the operation and maintenance of the facility to 'meet the engineer's design are the responsibility of the permittee, owner, and operator.

• ." •. "" , "!_ I

Granting this permit lIoes not imply that DEQ guarantees or ensures that the permitted facility, when constructed, will meet applicable permit conditions or other operational requirements. Compliance with all applicable standards remains the responsibility of the permittee.

Nothing in this permit constitutes an endorsement by DEQ of the construction or the design of the facility described herein. This permit verifies only that the submitted application meets the design and construction standards imposed by Wyoming statutes, rules and regnlations. The DEQ assumes no liability for, and does not in any way guarantee or warrant the performance or operation of the permitted facility. The permittee, owoer and operator are solely responsible for any liability arising from the construction or operation of the permitted facility. By issuing this permit, the State of Wyoming does not waive its sovereign immunity.

The permittee shall allow authorized representatives from DEQ to enter and inspect any property, premise or place on or at which the facility is located or is being constructed or installed for the purpose of investigating actual or potential sources of water pollution, and for determining compliance or non-compliance with any rules, regulations, standards, permits or orders.

Nothing in this permit shall be construed to preclude the institution of any legal action or other proceeding to enforce any applicable provision of law or rules and regulations. It is the duty of the permittee, owner and operator to comply with all applicable federal, state and local laws or regulations in the exercise of its activities authorized by this permit. The issuance of this permit does not convey any property rights in either real or personal property or any invasion of personal rights, nor any infringement of federal, state or local laws or regnlations.

The permittee shall construct and operate the permitted facility in accordance with the statements, representations, procedures, terms and conditions of the permit application, supporting documents and pemlit. This permit does

Page 88: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

not relieve the permittee from 'any dutyt(/obtaw ariybtherpermit or!luthorization that may be required by any provision of federal, state orlocallaws, . '.' . '.," _. ".

In carrying out its activjtiesauthorized by this p~;.mii;tliepeimitt~~;'owner and operator shall comply with all of the following permit conditions: .

,,-.. _ -.- ., __ ,c,.'.:;_ i; ._~,-; ~.- -:-i'~.'~ . ,_" ';-J

I of4

2of4

3 of4

40f4

"" -,' <-,-'-'-'---/'- --' - -': - ,,- - - " "

Theapplicant~ilLprovyle.innnedi~teoml or. written notice to the Northeast District, Water QualitY Division, 152 N(;~ Durbin;. Suite 1 00, Casper; WY ; 826(}1 , Phone 307':4 73-3465 ,FAX 307-473~3458,inaccordance with the provisions of S()ctionl1, Chapter 3, Wyoming Water Quality Rules and Regulati()lls of any changes or modifications which are not consistent with the terms' and conditions of this permit.

Within sixtyd~ys o(cori,pletioiiofc6rtl!inI~tion'ofthe 'authorized facility, the applicant will SUbmittoth~ Northeast District,)Vater9u1V&l)ivision, 152 North Durbin, Suite 100, Casper, WY,8260La certification of completiollsigneli by the Engineer of Record or the oWner. A form titled "Certificate of Completion" has been provided and must be completely filled out. -'-~f<" -,',' - - --'- ., - '~."'. ' -". -' ,- - - - -,,-.,,- , . ,'I

'~'-'-'

"'i~hl:Thi~da§§.()f.()Olllpleti?n. ofMn~tructi()n of theallfuorized facility, the Engineer of ;Recor~wnsubmit .twp(2)completecopie~ ofth~Operation and Maintenance Mannals to the N oitheilst District,W ater Quality Division, lsi North Durbin, Suit~ 1 00; Casper, WY 82601.

The re"iewand approv';l of this peimitis\)ased upon the items identified in the attached "Statement of Basis".

AUTHORlZEDBY: .'

Kevin Frederick . , . . . Administrator . Water Quality Division

Date of Issuance

KLFfrml13-0581

Todd Parfitt Director' Department of Environmental Quality

cc:David Myers, P.E.,HDREtlgiueering, Inc., P.O.:Bmi457, Gillette,WY82717 John Gillis, PhD, EPA Region 8, 1595 Wynkoop Street, Denver, CO 80202-1129 Kevin King,P.E.; Campbell Coimty Public Works, 500 South Gillette Avenue, Suite 1500, Gillette,WY 82716

(

(

Page 89: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

STATEMENT OF BASIS

1. Pennit Number: 13-122

2. Application reviewed for compliance with the following applicable regulations:

CHAPTER 3 AND CHAPTER 12 OF THE WYOMING WATER QUALI1Y RULES AND . REGULATIONS······ .......... - ............ ... . ............... _ .. '. ... ... ........ .. . ... ..

3. Does the pennit comply with all applicable regulations identified above?

NO. A VARIANCE HAS BEEN GRANTED FOR VALVE SPACING GREATER THAN 800'. A SPACING OF APPROXIMATELY 1600' WILL BE ALLOWED DUE TO THE RURAL NATURE OF THE TRANSMISSION LINE AND THE OPERATING PROCEDURES OF THE WRIGHT WATER AND SEWER DISTRICT.

4. Facilities include components not specifically covered or differing from applicable regulations and approval is based upon a deviation in accordance with Section 5.

5. A review to determine groundwater impacts in accordance with Section 17, Chapter 3 is not required.

6. Documentation of Statement of Basis: The archive file for this pennit includes adequate documentation of all sections of this Statement of Basis.

CERTIFICATION

The issuance of this permit is based upon a review of the application package submitted in accordance with the requirements of Chapter 3, Section 6, Wyoming Water Quality Rules and Regulations. This review was performed by Karen L. Farley, P.E., and completed on June 26, 2013. Pennit issuance is recommended based upon statements, representations, and procedures presented in the pennit application and supporting documents, pennit conditions, and the items identified in this "Statement of Basis."

Page 90: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(

(

Page 91: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality

To protect, conserve, and enhance the quality of Wyoming's

environment for the benefit of current and future generations.

Matthew H. Mead, Governor 152 N. Durbin St., Suite 100 . Casper, WY 82601 • (307) 473-3450

May 17, 2013

David G. Meyers, P.E. HDR P.O. Box 457 Gillette, WY 82717

John Carra, Director

RE: Wright Water and Sewer District - RJ-7 Well Completion, Transmission Pipelines, and Pumphouse Project Location: S y, of Section 34, Township 44 North, Range 72 West and N Y, of Section 3, Township 43 North, Range 72 West. WDEQ Application #13-122

Dear Mr.Meyers:

We have completed our review of the permit application submitted on March 19, 2013. Attached you will find a summary of the review comments. Please provide the information requested as soon as possible. Please feel free to contact me at (307) 473-3478 should you have any questions related to these comments or the application and review process.

Sincerely,

~~'/.~ Karen 1. Farley, P.E. Northeast District Engineer WDEQ/WQD

Attachments: WDEQ Comments

ce: IPS WDEQFile

Cherenne' 122 West 25' Street 82002

(307)777-7937

Lander 510 Meadowview Drive 82520

(307) 332-3144

Sheridan 2100 W. 5th Street 82801

(307) 673-9337

Page 92: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

REVIEW OF PLANS & SPECIFICATIONS WYOMING DEPARTMENT OF ENVIRONMENTAL QUALIT\;

WATER QUALITY DIVISION

PROJECT:

LOCATION:

ENGINEER:

APPLICANT:

152 North Durbin Street, Suite 100 Casper, Wyoming 82601

Phone (307) 473-3465

Wright Water and Sewer District - RJ-7 Well Completion, Transmission Lines, and Pumphouse

Wright, Wyoming

HDR Engineering

Wright Water and Sewer District

WATER QUALITY DIVISION APPLICATION NUMBER: 13-122

DATE ON PROPOSALIPLANS/REPORT: March,2013

DATE RECEIVED BY DEQ: March 19,2013

DATE OF THIS REVIEW: May 16,2013

WDEQ REVIEWER: Karen L. Farley, P .E.

ACTION: NOT AUTHORIZED FOR CONSTRUCTION. In accordance with Chapter 3, Section 14 (a), Wyoming Water Quality Rules and Regulations (WWQRR), the application is denied because it is incomplete and/or contains errors. Please address the comments outlined below and submit the requested information/clarifications in order that the application process may be completed in accordance with Chapter 3, Section 9 of the WWQRR. If the applicant fails to provide the requested information within six months, the incomplete application shall be returned. This review may not include all deficiencies and shall not be construed as a complete comprehensive list.

WDEQ COMMENTS

RJ-7WELL

1) Chapter 12, Section 9(b)(ii)(A) - Yield and drawdown tests. "The test pump capacity, at maximum anticipated drawdown, shall be at least 1.5 times the design rate anticipated The test

('

(;

shall provide for continuous pumping for at least 24 hours or until stabilized drawdown has continuedfor at least 6 hours when test pumped at 1.5 time the design rate. "If a design rate of ( )

2

Page 93: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

300 gpm is proposed, the well must be pump tested at 1.5 times that rate, or 450 gpm. The Level II Study provided information that it was only tested at 300 gpm.

TRANSMISSION LINES

2) Chapter 12, Section 14(b)(vii) - The design report indicates that flushing hydrants will be located at low points on the transmission lines. Please confirm and provide calculations that show that the flushing hydrants proposed are capable of flushing the lines a minimum of2.5 feet per second.

3) Chapter 12, Section 14(f)(vii) - Please provide information on what pressure the lines will be pressure-tested at.

GENERAL COMMENTS

4) Sheet 13 - The existing ground profile seems correct, but the water line profile does not. Please address.

5) The design report doesn't specifically discuss the proposed counection from the new 12" Transmission Loop line to an existing 6" line shown on Sheet 20. Please provide infonnation on this connection - what is it for, what are the existing pressures, etc.

6) Sheet 23 - The proposed 12" water transmission main appears to cross under (or over) an existing culvert; it's difficult to tell because there is no information on the cui vert inverts -please address.

7) Sheets 32&33 - The elevation labels that are shown along the middle of the profile appear to be incorrect or swapped - please address.

8) Chapter 12, Section 14(e)(i) - Sheet 27 - Please address the high point shown in this proposed alignment.

9) Sheet 29 - The proposed 12" gate valve and blow off valve assembly at Station 213+50 appear to be proposed for the existing 8" line; please address.

3

Page 94: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(\

(;

( )

Page 95: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality To protect, conserve and enhance the quality of Wyoming's

environment for the benefit qf current and future generations.

Matthew H. Mead, Go"Vcrnot

NOTIFICATION OF COVERAGE

April 25, 2013

City of Laramie Attn: Richard Elliott, Public Works Director 405 Ivlnson Street P.O. BoxC Laramie, Wyoming 82073

RE: Laramie SPT Phase 3, Schedule 2 - Hillside Dr. & Connecting Alley to the South

Application No. 13·123, Albany County

Dear Mr. Ellioll:

- Water & Sewer Replacements

Todd Parfitt, Director

The above application for coverage under General Permit to Construct, Install, Modify or Operate Extensions to or Modifications of an Existing Sewage Collection System consisting of replacing approximately 700 linear feet of 8" VCP sewer main with new 8" PVC sanitary sewer pipe. and on8(1) new manhole, and Existing Water Supply Distribution System conSisting of replacing approximately 1050 linear feet of old water main with new B" PVC water pipe. ten(10) gate valves, and two(2) new fire hydrants, located in Section 3, T15N, R73W, Albany County In accordance with Chapter 3, Section 9 of the Wyoming Water Quality Rules and Regulations has been reviewed and is hereby approved. You are authorized to construct, install or modify the sewage collection system in accordance with Chapter 11, Section 9 of the Water Quality Division Rules and Regulations, the water distribution system in accordance with Chapter 12, Section 14 of the Water Quality Division Rules and Regulations, and both systems in accordance with the general permits, and the materials submitted in your application package. Your attention is directed to the mandatory reporting requirements outlined in Part V, Section 0 of the general permits. All construction, installation, or modification allowed by this Notification of Coverage shall be completed by April 25, 2015.

This Notice of Coverage is covered under the General Permits on the Wyoming Department of Environmental Quality webpage. The General permits can be viewed at the following path:

b!!R:lldeg.state.wy.us/wgd/www/Permitting/Pages/general permlts.asp

Please reference Application No. 13-123 in any future correspondence.

If you have any questions, please contact me at either [email protected] or by phone at (307) 777-6183.

Sincerely,

~7-~ Ronald L. Ewald Assistant Southeast District Engineer Water Quality Division

RLE/rm/13-0370

Enclosures: Certificate of Completion form cc: IPS, Cheyenne

Cal Van Zee, City of Laramie Utility Operator, P.O. Box C, 1167 N. 4th, Laramie,

Wyoming 82073 Forrest Todd, WWC Engineering, 611 Skyline Road, Laramie, Wyoming 82070

lIerschlel' Building • 122 West 25th Street· Cllcycnne, WY 82001. • httpllldeq.state.wy.ll-s ADMINroUl1U!:ACH AnANDONJW MINES AIR QUALrl'Y 1NDUSl'lUALSrnN~ LA.NDQUALITY sor,1D &ItAZ. WAST}t WAl''KRQUAIJTY

(307) 177-7758 (301) '117-61'1-5 (01) 117·73!1'I (107)177-7369 {301)177-77S6 (307)177-7752 (301)177-7181 FAX 771·76WJ. FAX 7'17-6462 FAX 17'1.56!6 FAX'I7'l-59?> foAX777·S864 VAX 117-S97? JlAX777-S913

Page 96: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(,

(,

Page 97: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

WYOMING DEPARTMENT OF ENVIRONMENTAL QUALITY WATER QUALITY DIVISION PERMIT TO CONSTRUCT

PERMIT NO. 13-124

Ross Recovery Commercial Oilfield Wastewater Evaporation Pond Expansion #2

This permit hereby authorizes the applicant:

Ross Recovery. Inc. 3493 Ross Road

Douglas. Wyoming 82633

to construct, install or modify two (2) additional evaporative pond cells for the disposal of oilfield exploration and production wastewater at an existing commercial oilfield wastewater disposal facility, according to the procedures and conditions of the application number 13-124. The facility is located near the center of the south half of Section 13, Township 39 North, Range 75 West, in the county of Converse, in the State of Wyoming. The facility is located approximately 40 miles northeast of Glenrock, Wyoming. All construction, installation, or modification allowed by this permit shall be completed by May 1, 2018.

The issuance of this permit confirms that the Wyoming Department of Environmental Quality (DEQ) has evaluated the application submitted by the permittee and determined that it meets minimum applicable construction and design standards. The compliance with construction standards and the operation and maintenance of the facility to meet the engineer's design are the responsibility of the permittee, owner, a nd operator.

Granting this permit does not imply that DEQ guarantees or ensures that the permitted facility, when constructed, will meet applicable discharge permit conditions or other effluent or operational requirements. Compliance with discharge standards remains the responsibility of the permittee.

Nothing in this permit constitutes an endorsement by DEQ of the construction or the design of the facility described herein. This permit verifies only that the submitted application meets the design and construction standards imposed by Wyoming statutes, rules and regulations. The DEQ assumes no liability for, and does not in any way guarantee or warrant the performance or operation of the permitted facility. The permittee, owner and operator are solely responsible for any liability arising from the construction or operation of the permitted facility. By issuing this permit, the State of Wyoming does not waive its sovereign immunity.

The permittee shall allow authorized representatives from DEQ to enter and inspect any property, premise or place on or at which the facility is located or is being constructed or installed for the purpose of investigating actual or potential sources of water pollution, and for determining compliance or non­compliance with any rules, regulations, standards, permits or orders.

Nothing in this permit shall be construed to preclude the institution of any legal action or other proceeding to enforce any applicable provision of law or rules and regulations. It is the duty of the permittee, owner and operator to comply with all applicable federal, state and local laws or regulations in the exercise of its activities authorized by this permit.

The issuance of this permit does not convey any property rights in either real or personal property or any invasion of personal rights, nor any infringement of federal, state or local laws or regulations.

Page 98: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

The permittee shall construct and operate the permitted facility in accordance with the statements, representations, procedures, terms and conditions of the permit application, supporting documents and ( permit. This permit does not relieve the permittee from any duty to obtain any other permit or authorization that may be required by any provision of federal, state or local laws.

In carrying out its activities authorized by this permit, the permittee, owner and operator shall comply with all of the following permit conditions:

1 of 14 The applicant will notify the CBM I Oil and Gas Group, Water Quality Division, 152 North Durbin Street, Suite 100, Casper, WY 82601, Phone 307-473-3465, FAX 307-473-3458 of the date construction will begin and the estimated completion date.

2 of 14 The applicant will provide the CBM I Oil and Gas Group, Water Quality Division, 152 North Durbin Street, Suite 100, Casper, WY 82.601, the name of the type and brand of the primary and secondary liner, the liner manufacturer(s), the liner installation contractor(s), and ali other required documentation related to the liners, at least two weeks prior to beginning construction. The manufacturer(s) will need to submit recommended installation methods that include cold weather installation. At a minimum, installation should be conducted in accordance with "Cold Weather Seaming of Geomembranes", Geosynthetic Institute, GRI Test Method GM9 or a comparable method.

3 of 14 The applicant will provide immediate oral or written notice to the CBM I Oil and Gas Group, Water Quality Division, 152 North Durbin Street, Suite 100, Casper, WY 82601, Phone 307-473-3465, FAX 307-473-3458, in accordance with the provisions of Section 11, Chapter 3, Wyoming Water Quality Rules and Regulations of any changes or modifications which are not consistent with the terms and conditions of this permit.

4 of 14 Within sixty days of completion of construction of the authorized facility, the applicant will submit to the CBM I Oil and Gas Group, Water Quality Division, 152 North Durbin Street, Suite 100, Casper, WY 82601, a certification of completion signed by the Engineer of Record or the owner. A form titled "Certificate of Completion" has been provided and must be completely filled out.

5 of 14

6 of 14

7 of 14

The review and approval of this permit is based upon the items identified in the attached "Statement of Basis".

Measurement of depth to groundwater and testing of groundwater is to be performed prior to filling any ponds at this facility.

Groundwater monitoring will be conducted on a quarterly basis and results reported to DEQ within a month after receiving laboratory analytical reports. Samples will be submitted for the following analysis:

a) electrical conductivity b) pH c) chloride d) sodium e) alkalinity f) sllifate g) total dissolved solids

(

(

Page 99: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

The analyte list and monitoring frequency are subject to revision as needed by CBM / Oil and Gas Group, Water Quality Division. Groundwater monitoring will also include measurement of depth to groundwater and the preparation of a potentiometric surface map, to be included with the analytical data.

8 of 14 The leak detection system is to be checked weekly for the first month following filling of a pond and monthly thereafter with a log kept of the inspection results. As new ponds are constructed, the leak detection system is to be checked weekly for the first month. If fluid is found, the DEQ CBM / Oil and Gas Group is to be notified immediately, and samples are to be pulled from the inspection pipes and tested for total petroleum hydrocarbons, Gasoline Range Organics (GRO) and Diesel Range Organics (DRO) by EPA Method 8015 (modified), chlorides, total dissolved solids (TDS) and sulfates. Results are to be reported to DEQ as soon as they are available. Testing requirements are subject to revision as needed.

9 of 14 Operational concerns will be identified in an annual report to be submitted to DEQ by April 1 of each year. Any changes in operations, a discussion of groundw?ter monitoring, leak detection system operation, and pond characterization is to be include~. i,n th~ qnnual.report.

10 of 14 Fluids in the ponds are to be checked annually for the following constituents. Each pond will be sampled and analyzed separately in accordance with the following list:

a) electrical conductivity b) pH c) chloride d) sodium e) alkalinity f) sulfate g) barium h) total dissolved solids

The results of the pond analyses are to be reported to DEQ within one month after receiving laboratory analytical reports. The analyte list and monitoring frequency are subject to revision by CBM / Oil and Gas Group, Water Quality Division.

11 of 14 The facility is authorized to receive oilfield exploration and production waste (production water, produced water, and frac water), exempt from RCRA regulations by EPA. Any other waste must be approved on a case by case basis by the DEQ and the owner. Prior to approval for disposal by DEQ/WQD, all other waste will be subject to rules, regulations, policies, and/or procedures related to hazardous waste deterrnination and disposal, as issued or promulgated by DEQ/Solid and Hazardous Waste Division (SHWD).

12 of 14 Additional geologic and hydrogeologic investigations will be required prior to construction of Pond 6. The additional investigations must be reviewed and approved by WDEQ prior to any construction activities.

13 of 14 The validity of this permit is subject to the owner maintaining a bond acceptable to the State of Wyoming, DEQ/WQD for the amount of the facility closure and post-closure costs. The bonding amount is subject to review on an annual basis. The bond amount may be "phased­in", in accordance to the facility construction. However, prior to construction of any pond, financial assurance must be in place which covers the next construction phase. This additional bonding must be acceptable to the State of Wyoming prior to any construction related to that phase.

Page 100: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

14 of 14 An annual report will be submitted to DEQ CBM / Oil and Gas Group by April 1 of each year. The annual report will include relevant details of the construction, modification, and operation details of the facility from the previous year, any anticipated construction, ( modification and/or operational changes for the upcoming year. The report will include a _ discussion and analysis of the groundwater monitoring, leak detection monitoring and pond analysis. A listing of all non exploration and production wastes accepted by the facility will also be included in the annual report. This listing shall include generator, type of waste, amount and date of disposal. The annual report will also include a review of the closure and post closure requirements, including financial costs. A renewal of the bond will be required as part of the annual report. Reporting requirements are subject to modification by DEQ.

AUTHORIZED BY:

Kevin Frederick Administrator Water Quality Division

Date of Issuance_~SL----,I,-,b",---,\,-,~,=,-__ _

TP/KF/JDL/KJM/bb/13-0395

cc: Darrin Tromble, WWC Engineering, 6000 East 2nd Street, Suite 1004, Casper, WY 82609

(

(

Page 101: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

STATEMENT OF BASIS

1. Permit Number: 13-124

2. Application reviewed for compliance with the following applicable regulations:

Chapters 3 and 11 of the Wyoming Water Quality Rules and Regulations

3. Does the permit comply with all applicable regulations identified above?

4. Facilities include components not specifically covered or differing from applicable regulations and approval is based upon a deviation in accordance with Section 5.

a. The permit includes approval to deviate from the following regulatory requirements:

Not applicable

b. Briefly state the basis for the deviation.

Not applicable

c. Permit approval is based upon deviation from applicable regulations in accordance with approved policy statement.

Not applica ble

5. A review to determine groundwater impacts in accordance with Section 17, Chapter 3 was required.

6. If Section 17 of Chapter 3 review is required, indicate the basis for determining groundwater will be protected.

The facility will not allow a discharge to groundwater.

The pond will have a primary liner of 60 mil high density polyethylene with a 40 mil high density polyethylene secondary liner. A compacted clay subgrade will be installed under the secondary liner. A leak detection system will be installed between the two liners. Groundwater monitoring wells will also be installed at the facility to monitor groundwater on a quarterly basis.

Quality of wastewater is such that it will not cause a violation of groundwater standards.

Not applicable

Existing soils or geology will not allow a discharge to groundwater.

Not applicable

The facility is designed and will be operated so that it will not to violate groundwater standards.

Page 102: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Not applicable

Discharge will result in groundwater concentrations in excess of standards but post discharge ( water quality can be returned to standards in accordance with Section 4 (d)(vi), Chapter VIII. Briefly describe:

Not applicable

If any groundwater quality standards are to be exceeded, briefly describe how any users of the affected aquifer will be protected. The description should include the water quality standard affected, the anticipated maximum concentration, the property boundaries, places of groundwater withdrawal and any other relevant information.

Not applicable

Briefly describe monitoring plan. The groundwater monitoring plan includes the monitoring wells or other sampling points, the parameters to be analyzed, the sampling frequency and reporting methods.

The leak detection system will be checked weekly for the first month after the ponds are filled. A log will be kept of the inspection results. The leak detection system is also monitored by a high level alarm system. If fluid is found, DEQ will be notified immediately.

Measurement of depth to groundwater and testing of groundwater is to be performed prior to filling any ponds at this facility. Groundwater monitoring will be conducted on a quarterly basis and results reported to DEQ within a month after receiving laboratory analytical reports. ( ,

Fluids in the pond are to be checked annually for constituents by collecting a sample from each pond in operation.

Operational concerns will be identified in an annual report to be submitted to DEQ by April 1 of each year. Any changes in operations, a discussion of groundwater monitoring, leak detection system operation, and pond characterization is to be included in the annual report.

The permit should clearly state the parameters to be utilized for determining compliance and what occurrences constitute a violation. The permit should identify the corrective actions to be taken in the event of a violation of a groundwater standard.

Documentation of Statement of Basis.

The archive file for this permit includes adequate documentation of all sections of this Statement of Basis.

CERTIFICATION

The issuance of this permit is based upon a review of the application package submitted in accordance with the requirements of Chapter 3, Section 6, Wyoming Water Quality Rules and Regulations. This review was performed by Kim Medina and Dennis Lamb, CBM / Oil and Gas Group and completed on April 29, 2013. Permit issuance is recommended based upon statements, representations, and procedures presented in the permit application and supporting documents, permit conditions, and the items identified in this "Statement of Basis." (

Page 103: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality

Matt Mead, Governor

April 16, 2013

To protect, conserve and enhance the quality of Wyoming's environment for the benefit of current and future generations.

NOTIFICATION OF COVERAGE

David Plute, NWC Physical Plant Director Northwest College 231 W 6111 Street Powell, WY 82435

RE: NWC-Yellowstone Academic Building DEQ Permit #13-126

Todd Parfitt, Director

Located In Park County, T 55N, R 99W, SiD, L75H; Let. 44.7613, Long. -108.7647

Dear Mr. Plute,

This project consists of the installation of approximately 245 linear feet of 6-inch AWWA C900 PVC fire sprinkler line from Division Stnset to a new building.

The above application. for coverage under, General Permit has been reviewed in accordance with Chapter 3, Section 7; and Chapter 12 of the Wyoming Water Quality Rules and Regulations and is hereby approved.

You are authorized to construct, the facility in accordance with the the materials submitted in your application package and the General Permit to Construct, Install, Modify or Operate Extensions to or Modification to Existing Public Water Supply Distribution Systems. Construction shall be completed by October 31,2015

Your attention is directed to the attached Certificate of Completion form, Which, is to be submitted within 60 days of the completion of !he aforementioned project.

These General Permit requirements can be downloaded from the Wyoming Department of Environmental Quality webpage. The General Permits can be found under the Water Quality Division Water and Wastewater Program, Engineering and Technical Services at:

http://deg.state.wy.us/wgdIwwwJPermitting/PagesJgeneral permits. asp

If you have any questions, please contact Hannes Stueckler at 307-335-6964 or James Brough at 307-335-6961. '

s~nc~ . /l.-----Ha nes E. Stueckler, P.E. Assistant Northwest District Engineer Water Quality Division

xc: PDF to Cheyenne Robert A. Overfield, Engineering Associates, P.O. Box 1900, Cody, WY 82414

Lander Field Office· 510 Meadowview Drive· Lander, WY 82520 • http://deq.state.wy.us ABANDONED MINeS

(307) 332·5085 FAX 332·7726

AIR QUALITV (307) 332·6765 IW(332·7726

lAND QUALITY (307) 332·3047 FA)( 332,7726

SOLIP & HAZARDOUS WASTE (307) 332·6924 FAX 332·7726

WATER QUALrrv (3071 332·3144 FAX 332·7726

Page 104: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(

(J

Page 105: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

WYOMING DEPARTMENT OF ENVIRONMENTAL QUALITY WATER QUALITY DIVISION PERMIT TO CONSTRUCT

PERMIT NO.13-127

COUNTRY MEADOWS WASTE WATER DECHLORINATION UNIT

This permit hereby authorizes the applicant:

Country Meadows, LLC Harland Zimmerman, Owner 7872 Regency Park Street

Las Vegas, NV 89149

to construct, install or modify one dechlorination unit according to the procedures and conditions of the application number 13-127. The facility is located in NW 1/4 of Section 12, T15N R73W; Albany County, in the State of Wyoming. All construction, installation, or modification allowed by this permit shall be completed May 3, 2015.

The issuance of this permit confirms that the Wyoming Department of Environmental Quality (DEQ) has evaluated the application submitted by the permittee and determined that it meets minimum applicable construction and design standards. The compliance with construction standards and the operation and maintenance of the facility to meet the engineer's design are the responsibility of the permittee, owner, and operator.

Granting this permit does not imply that DEQ guarantees or ensures that the permitted facility, when constructed, will meet applicable discharge permit conditions or other effluent or operational requirements. Compliance with discharge standards remains the responsibility of the permittee.

Nothing in this permit constitutes an endorsement by DEQ of the construction or the design of the facility described herein. This permit verifies only that the submitted application meets the design and construction standards imposed by Wyoming statutes, rules and regulations. The DEQ assumes no liability for, and does not in any way guarantee or warrant the performance or operation of the permitted facility. The permittee, owner and operator are solely responsible for any liability arising from the construction or operation of the permitted facility. By issuing this permit, the State of Wyoming does not waive its sovereign immunity.

The permittee shall allow authorized representatives from DEQ to enter and inspect any property, premise or place on or at which the facility is located or is being constructed or installed for the purpose of investigating actual or potential sources of water pollution, and for determining compliance or non­compliance with any rules, regulations, standards, permits or orders.

Nothing in this permit shall be construed to preclude the institution of any legal action or other proceeding to enforce any applicable provision of law or rules and regulations. It is the duty of the permittee, owner and operator to comply with all applicable federal, state and local laws or regulations in the exercise of its activities authorized by this permit.

The issuance of this permit does not convey any property rights in either real or personal property or any invasion of personal rights, nor any infringement of federal, state or local laws or regulations.

The permittee shall construct and operate the permitted facility in accordance with the statements, representations, procedures, terms and conditions of the permit application, supporting documents and permit. This permit does not relieve the permittee from any duty to obtain any other permit or authorization that may be required by any provision of federal, state or local laws.

Page 106: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

In carrying out its activities authorized by this permit, the permittee, owner and operator shall comply with all of the following permit conditions:

1 The applicant will provide immediate oral or written notice to the Southeast District, Water Quality Division, Herschler Building 4 West, Cheyenne, WY, 82002, Phone 307-777-7088, FAX 307·777-7610, in accordance with the provisions of Section 11, Chapter 3, Wyoming Water Quality Rules and Regulations of any changes or modifications which are not consistent with the terms and conditions of this permit.

2. For acceptable operation of the entire disinfection process, the chlorination unit must continually operate at least three (3) of the chlorination tablet tUbes.

3. Within sixty days of completion of construction of the authorized facility, the applicant will submit to the Southeast District, Water Quality Division, Herschler Building 4 West, Cheyenne, WY, 82002 a certification of completion signed by the Engineer of Record or the owner. A form titled "Certificate of Completion" has been provided and must be completely filled ·out.

4. The review and approval of this permit is based upon the items identified in the attached "Statement of Basisll,

AUTHORIZED BY:

Kevin Frederick Administrator Water Quality Division

Date of Issuance 0.. -s -\~

SWT/rm/13-0844

Director Department of Environmental Quality

(

(

(!

Page 107: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

STATEMENT OF BASIS

I. Permit Number: 13-127

2. This application was reviewed for compliance with the applicable regulations;

Chapters 3, II

3. Does the permit comply with all applicable regulations identified above?

4. A review to determine grOlmdwater impacts in accordance with Section 17, Chapter 3 was not required.

Sewerage Systems are exempted from review by Chapter 3, Section 17.

5. Documentation of Statement of Basis: The archive file for this permit includes adequate documentation of all sections of this Statement of Basis.

CERTIFICATION

The issuance of this permit is based upon a review of the application package submitted in accordance with the requirements of Chapter 3, Section 6, Wyoming Water Quality Rulcs and Regulations. This review was performed by Seth Tourney, Southeast District Engineer, Water and Wastewater Section, Wyoming Department of Environmental Quality /Water Quality Division, and completed on September 4, 2013. Permit issuance is recommended based upon statements, representations, and procedures presented in the permit application and supporting documents, permit conditions, and the items identified in this "Statement of Basis."

Page 108: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

('

(.

(:

Page 109: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality To protece consefV9, and enhance the qualhy of WyomIng's

envIronment for tha beneOt of current and tiJlUl'e generations.

Matthew H. Mead. Governor 152 N. DurbinS!., Suite 100 • Casper, WY 82601 • (307) 473-3450

May 23, 2013

Jason Harms Hanus oil Company 337 22'><1 Avenue South Brookings, SD 57006

NOTIFICATION OF COVERAGE

RE: Coffee Cup Reconstruction - Waterline Relocation, Moorcroft, WY WDEQ Application No. 13-128, Crook Couuty

Dear Mr. Harms:

John Corra, Dlreclor

The above application for coverage under General Permit to Construct, Install, Modify or Operate Extensions to or Modifications of Existing Water Supply Distribution Systems, consisting of the installation of approximately 650 lineal reet of 8" PVC waterline, located in the NE \4 ofSectio11 6, Township 49 North, Range 67 West, Tract E of the Texas Trails Subdivision, Moorcroft, WY, in accordance with Chapter 3, flection 9 of the Wyoming Water Quality Rules and Regulations has been reviewed and is hereby approved. You are authorized to construct, iustall, or modify the facility iu accordance with Chapter 12 of the Water Quality Division Rules and Regulations, the general permit, and the materials submitted in your application package. Your attention is directed to the mandatory reporting reljuirements outlined in Part V, Section 0 of the general permit. All construction; 'installation, or modification allowed by this Notification of Coverage shall be completed by December 31. 2014:

This Notification of Coverage is covered under the General Permits on the Wyoming Department of Environmental Quality webpage:

htt(2://deq.state.wv.lIs/wqd/wwwiPennitJ:jng/Pages/general Rermits.asp

If you have any questions, please contact me at 307-473-3478.

Sincerely,

~~t.~ Karen L. Farley, P.E. NE District Engineer WDEQ/WQD

co: IPS, Cheyenne WDEQ Casper File Robert A. Swanson, P.E., PCA Engineering, Inc., P.O. Box 2185, Gilletle, WY 82717 Steve Blakeman, Mayor, Town of Moorcroft, P.O. Box 70, Moorcroft, WY 82721

Ch~enne 122 West 25' Street 82002

(307) n7·7937

Lander 510 Meadowview Drive 82520

(307) 332-3144

Sheridan 2100 W. 5'" Street 82801

(307) 673-9337

Page 110: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

()

(!

Page 111: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality To protect, conserve, and enhance /he quality of Ji0tomlng;g

environment for the benefit of current and future generations.

Matthew H. Mead, Governor 152 N. Durbin St., Suite 100 ' Casper, WY 82601 • (307) 473·3450

April 23, 2013

Andrew Beamer, P,E. City of Casper 200 North David Street Casper, WY 82601

NOTIFICATION OF COVERAGE

RE: 2013 Miscellaneous Manhole Replacement Application No. 13-129, Natrona County

Deal' Mr. Beamer:

Todd Parfitt, Director

The ahove application for coverage under General Permit to Construct, Install, Modiry or Operate Extensions to or Modifications of Existing Sewage Collection Systems, consisting of the replacement of 13 manholes located in Section 2, Township 33N, Range 79W, Natrona County, in accordance with Chapter 3, Section 9 of the Wyoming Water Quality Rules and Regulations has been reviewed and is hereby approved. You are authorb>:ed to c.oostruci, install, or modiry the facility in accordance with Chapter 11 of the Water Quality Division Rules and Regulations, the general pennit, and the materials submitted in your application package. Your attention is directed to the mandatory reporting requirements ontlined in Part V, Section 0 of the general permit. All construction, installation, or modification allowed by this Notification of Coverage shall be completed by December 31, 2014.

This Notification of Coverage is covered under the General Permits on the Wyoming Department of Environmental Quality webpage: .

http://deg.state.wy. us/wqd/www/PermittingIPagesigeneral permits.asp

If you have any questions, please contact me at 307A73-3469.

Sincerely,

,?7-Z/ Jason Vreeland, P.E. Assistant NE District Engineer WDEQIWQD

ce: IPS, Cheyenne WDEQ Casper File

COO,enn. 122 West 2S' Street 82002

(307) 777-7937

Lander 510 Meadowview Drive 32520

(307)332·3144

Sheridan 2100W. S'h S1reet 82801

(307) 673·9337

Page 112: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

('

(I

Page 113: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality To protect, conserve, and enhance the quall/y of IIW<>mlngs

environment for the benefit of cummt and fUture geneJl3tJons.

Matthew H. Mead. Qovornor 152 N. Durbin SI., Sulle 100 . Casper, WY 82601 . (307) 473-3450

May 10,2013

Andrew Beamer, P.E. City of Cas pel' 200 North David Street Caaper, WY 82601

NOTIFICATION OF COVERAGE

RE: All American Center - Water and Sanitary Sewer Improvements Project Application No. 13-130, City ofCnsper, WY

Denr Mr. Beamel':

Todd Parfln, Dlroclor

The above application for covel'age under General Permits to Construct, Install, ModifY or Operate Extensions to or Modifications of Existing Water Supply Distribution Systems and Existing Sewage Collection Systems, consisting ofthe installation of approximately 600 lineal feet of 8 inch PVC sanitary sewer line and approximately 1200 lineal feet of 8 inch PVC water line, including associated fire hydrants, sanitary sewer manholes, and services, located in the SW V. ofNE V. of Section 3, Township 33 North, Range 79 West, Natrona County, in accordance with Chapter 3, Section 9 of the Wyoming Water Quality Rules and Regulations has been reviewed and is hereby approved. You are authorized to construct, install, or modifY the facility in accordancc with Chllpter 11 lind 12 of the Water Quality Division Rules and Regulations, the General Permits, and the materials submitted in your application package. Your attention is directed to the mandatory reporting requirements outlined in Part V, Section 0 of the general pcrmit. All construction, installation, or modification allowed by this Notification of Coverage shall be completed by December 31, 2014.

TWs Notification of Coverage is covered under the General Permits 011 the Wyoming Departmcnt of Environment.l Quality webpage:

http://deq.state.wy.lls/wQd/www/Permitting/Pages/generai permits.asp-

Tfyon have any questions, please contact me at 307-473-3478.

Sincerely,

'-I J ..;-r.. (} C.t'\CLV/I>'\ .j" -rc.j..V(·~"L

Karen L. Farley, P.E. 1 NE District Engineer WDEQ/WQD

cc: IPS, Cheyenne WDEQ Casper File Robert Bennett, P.E., CEPI, 6080 Enterprise Drive, Casper, WY 82609

Che~onllo 122 West 25' Slreel 82002

(307) 777-7937

Lander 510 Meadowview Drive 82520

(307)332-3144

Sheridan 2100 W. 51b Street 82801

(307) 673-9337

Page 114: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

('

(i

~~~~ ~---~---

Page 115: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

, t , .

, ,

Department of Environmental Quality To protect, conserve and enhance the quality of Wyoming's

environment for the benefit of current and fUture generations.

Matthew H. Mead, Governor Todd Porfi!t, DIrector

NOTIFICATION OF COVERAGE

May 13, 2013

Jordan Seitz 204% East Fourth, P.O. Box 484 Encampment, Wyoming 82325

RE: Seitz Residential Small Wastewater Disposal System, Application No. 13-131, Carbon County

Dear Mr. Seitz:

The above application for coverage under General Permitto Construct, Install, Modify or Operate a Small Wastewater Facility consisting of a 1000 gallon, two compartment, concrete septic tank discharging into about 168 feet of chamber type trench leachfield divided into three equal length trenches of at least 9 Infiltrator brand, Standard model chamber units each, fora 3 bedroom house, located in the SW% NE% Section 21, T16N, R83W, Carbon County, in accordance with Chapter 3, Section 9 of the Wyoming Water Quality Rules and Regulations has been· reviewed and is hereby approved. You are authorized to construct, install or modify the small wastewater system in accordance with Chapter 25 of the Water Quality Division Rules and Regulations, the general permit, the condition listed below, and the materials submitted in your application package. Your attention is directed to the mandatory reporting requirements outlined in Part V, Section 0 of the general permit. All construction, installation, or modification allowed by this Notification of Coverage shall be completed by May 13,2015.

The following project specific condition also applies:

Septic Tank Clean-Out Riser Requirement - Either a 6 inch diameter clean-out riser or the manway from each compartment of the septic tank must be extended to the ground surface.

_._.-

This Notice of Coverage is covered under the General Permits on the Wyoming Department of Environmental Quality webpage. The General Permits can be viewed althe 'following path:

l:!:tm ://d f29 .state.wy. us/wgd/www/P e rmitti ng/Pages/g en eral perm its, alill

Herscl\l",'lluilding . l7.2 W"t 25th Street· Cheye.n., WY 82002 • http,/Ideq.state.wy.n, ADMJN/OUTREAClI ABANDONEJJ M1NltS AlRQtJALIT¥ INDUIITRIALSITING LAND QUAUTY SOLID &HAZ. WASTE WATER QUALITY

(?,01) '/71-'175'8 (307) 7n-~145 (301)717-1391 (07) 771-1369 (3m) 7n-1756 (301) 777-n5? (307)1n-'1781 FAX 177-76&2 PAX ?17-{l462 lIAX 777-5616 FAX 777-5973 PAX 771--5864 FAX 171-5973 IIAX 717-5973 1\)-r

(. ; \ .. /

Page 116: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Please reference Application No. 13-131 in any future correspondence.

If you have any questions, please contact me at either [email protected] phone at (307) 777-6183.

Sincerely,

Ronald L. Ewald Assistant Southeast District Engineer Southeast District, Water & Wastewater Sectiofl Water Quality Division

RLE/rm/13-0441

Enclosures: Certificate of Completion form

cc: IPS, Cheyenne Kristy Rowan, Carbon County Planning Office, Carbon Building, 215 West Buffalo

Street, Suite 336, Rawlins, Wyoming 82301

I J

1 J ('

(

(

Page 117: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

WYOMING DEPARTMENT OF ENVIRONMENTAL QUALITY WATER QUALITY DIVISION

LAND APPLICATION PERMIT

PERMIT NO. 13-132

Indian Paintbrush Water Supply Land Application Project

This permit hereby authorizes the applicant:

Mike Calabrese. President Indian Paintbrush Water District

P.O. Box 100 Wilson. WY 83014

to land apply water from Indian Paintbrush Test Well. according to the procedures and conditions of application number 13-132. The water meets National Drinking Water Standards and will be applied during pump tests of a test well. The well will be pump tested for up to 48 hours at a flow rates between 20 and 100 gpm and the pumped water will be land applied to minimize live contact with any live streams. The application site is located in Section 33. T41 N. R117W in the county ofTeton, in the State of Wyoming. This permit shall be effective until October 1 , 2015.

The issuance of this permit confirms thatthe Department of Environmental Quality (DEQ) has evaluated the application submitted by the permittee and determined that it meets minimum applicable standards. Compliance with DEQ standards is the responsibility of the permittee, owner, and/or operator.

. Nothing in this permit constitutes an endorsement by the DEQ of the disposal method described herein. , This permit verifies only that the submitted application meets the standards imposed by the DEQ statutes,

rules and regulations. The DEQ assumes no liability for, and does not in any way guarantee or warrant the performance of, the permitted activity. The permittee, owner and/or operator are solely responsible for any liability arising from the waste disposal. permitted. By issuing this permit, the state does not waive its sovereign immunity. ' . ..

The permittee shall allow authorized representatives from the DEQ, Water Quality Division, to enter and inspect any property, premise or place on or af which the facility is located or is being constructed or installed for the purpose of investigating actual or potential sources of water pollution, and for determining compliance or non-compliance with any rules, regulations, standards, permits or orders.

Nothing in this permit shall be construed to preclude the institution of any legal action or other proceeding to enforce any applicable provision of law or rules and regulations. It is the duty of the permittee, owner and/or operator to comply with all applicable federal, state and local laws or regulations in the exercise oiits activities authorized by this permit.

The issuance of this permit does not convey any property rights in either real or personal property or any invasion of personal rights, nor any infringement of federal, state or local laws or regulations.

The permittee shall construct and operate the permitted facility in accordance with the statements, representations, procedures, terms and conditions of the permit application, supporting documents and permit. This permit does not relieve the permittee from any duty to obtain any other permit or authorization that may be required by any provision of federal, state or local laws.

, In carrying out its activities authorized by this permit, the permittee, owner and/or operator shall comply with all of the following permit conditions:

Page 118: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

1 of 4 Section 9, Chapter III, Wyoming Water Quality Rules and Regulations requires notification of DEQ for any changes or modifications to the approved permit package. The permittee shall provide immediate verbal or written notice to the Northwest District Engineer, Wyoming DEQ/WQD, 510 Meadowview Drive, Lander, WY 82520, phone 307-332-3144.

2 of 4 The water shall be discharged in a manner as to not cause unnecessary erosion.

3 of 4 The permittee shall provide certification that the project was completed in accordance with the terms and conditions of the permit within sixty (60) days ofthe project completion to the Northwest District Engineer on the attached Certification of Completion form.

a. Date that the land application was completed; and

b. Certification the land application was done in accordance with the terms and conditions of the permit; or

c. Certification the land application was completed with changes or modifications. Submit the information necessary to clearly indicate the land application as actually performed. This information shall include a contour map depicting only those sections of land that actually received.

4 of 4 The review and approval of this permit is based upon the items identified in the attached Statement of Basis.

AUTHORIZED BY:

Kevin Frederick Administrator Water Quality Division

~8>--\3 Date of Issuance

JSB/rm/13-0416

Todd Parfitt Director Department of Environmental Quality

(

(

(.

Page 119: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

STATEMENT OF BASIS

1. Permit Number: 13-132

2. Application reviewed for compliance with the following applicable regulations:

Chapter 11 of the Wyoming Water Quality Rules and Regulations.

3. Basis for issuing permit.

The water that will be land applied is groundwater that meets the National Drinking Water Standards.

4. Application requires review to determine groundwater impacts in accordance with Section 17, Chapter 3.

Public water supplies are exempted from review by Chapter 3, Section 17.

5. Documentation of Statement of Basis.

The archive file for this permit will include adequate documentation of all sections of this Statement of Basis.

CERTIFICATION

The issuance of this permit is based upon a review of the application package submitted in accordance with the requirements of Section 6, Chapter 3, Wyoming Water Quality Rules and Regulations. This review was performed by James S. Brough, [email protected], Northwest District Engineer and completed on April 26, 2013. Permit issuance is recommended based upon statements, representations, and procedures presented in the permit application and supporting documents, permit conditions, and the items identified in this "Statement of Basis."

cc: Kevin Boyce, P.G, Wyoming Water Development Commission, 6920 Yellowtail Rd., Cheyenne, WY 82002 Mark Stacy, P.G., Lidstone & Associates, Inc., 4025 Automation Way, Bldg. E., Fort Collins, CO 80525

F:\divislon\WQD\W&WW Section\2013 Permits & Reviews\13-132.lndianPaintBrush __ Land_Appl.jsb,doc

Page 120: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(

(

Page 121: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

WYOMING DEPARTMENT OF ENVIRONMENTAL QUALITY WATER QUALITY DIVISION

PERMIT NO. 13-133

PERMIT TO CONSTRUCT

Indian Paintbrush Test Well Drilling & Testing PWS #WY5600758

This permit hereby authorizes the applicant:

Mike Calabrese. President Indian Paintbrush Water District

P.O. Box 100 Wilson. WY 83014

to drill, construct. develop and test a new well for Indian Paintbrush Water District, according to the procedures and conditions of the application number 13c133. A successful test well could be the district's third public supply well and the target yield for the new well is 60 gpm. The new well is within Section 33, T41 N, R117W in the county of Teton, in the State of Wyoming. All construction, installation, or modification allowed by this permit shall be completed by October 1, 2015.

The issuance ofthis permit confirms that the Wyoming Department of Environmental Quality (DEQ) has evaluated the application submitted by the permittee and determined that it meets minimum applicable construction and design standards. The compliance with construction standards and the operation and maintenance of the facility to meet the engineer's design are the responsibility of the permittee, owner, and operator.

iranting this permit does not imply that DEQ guarantees or ensures that the permitted facility, when constructed, will meet applicable discharge permit conditions or other effluent or operational requirements. Compliance with discharge standards remains the responsibility of the permittee.

Nothing in this permit constitutes an endorsement by DEQ of the construction or the design ofthe facility described herein. This permit verifies only that the submitted application meets the design and construction standards imposed by Wyoming statutes, rules and regulations. The DEQ assumes no liability for, and does not in any way guarantee or warrant the performance or operation of the permitted facility. The permittee, owner and operator are solely responsible for any liability arising from the construction or operation of the permitted facility. By issuing this permit, the State of Wyoming does not waive its sovereign immunity.

The permittee shall allow authorized representatives from DEQ to enter and inspect any property, premise or place on or at which the facility is located or is being constructed or installed for the purpose of investigating actual or potential sources of water pollution, and for determining compliance or non-compliance with any rules, regulations, standards, permits or orders,

Nothing in this permit shall be construed to preclude the institution of any legal action or other proceeding to enforce any applicable provision of law or rules and regulations. It is the duty of the permittee, owner and operator to comply with all applicable federal, state and local laws or regulations in the exercise of its activities authorized by this permit.

The issuance of this permit does not convey any property rights in either real or personal property or any invasion of personal rights, or any infringement of federal, state or local laws or regulations.

The permittee shall construct and operate the permitted facility in accordance with the statements, representations, irocedures, terms and conditions of the permit application, supporting documents and permit. This permit does not

Page 1 of 3

Page 122: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

relieve the permittee from any duty to obtain any other permit or authorization that may be required by any provision offederal, state or local laws.

In carrying out its activities authorized by this permit, the permittee, owner and operator shall comply with all of the ( \ following permit conditions:

1 of 4 The applicant will provide immediate oral or written notice to the Wyoming Department of Environmental Quality, Water Quality Division (WQD), Northwest District Engineer, 510 Meadowview Drive, Lander, WY 82520, 307-332-3144,FAX 307-332-3183, in accordance with the provisions of Section ii, Chapter 3, Wyoming Water Quality Rules and Regulations of any changes or modifications which are not consistent with the terms and conditions of this permit.

2 of 4 A permit to construction application along with plans and technical specifications for the equipping ofthe well and other construction such as installation of discharge piping, construction of a well house, disinfection, etc. must be submitted to the Wyoming Department of Environmental Quality. A Permit to Construct must be obtained prior to construction of the aforementioned items.

3 of 4 Within sixty days of completion of construction of the authorized facility, the applicant will submit to the Northwest District a certification of completion signed by the Engineer of Record or the owner. A form titled "Certificate of Completion" has been provided.

a. Date that construction of the facility was completed; and

b. Date that the facility was placed in operation; and

c. Certification the facility was constructed in accordance with the terms and conditions of the permit; or

d. Certification the facility was completed with changes or modifications. Submittal of as-construc;ted plans and specifications for the system as it was constructed, certified by an engineer if appropriate is(' required. All modifications or deviations from the authorized plans must be highlighted.

4 of 4 The review and approval of this permit is based upon the items identified in the attached "Statement of Basis".

AUTHORIZED BY:

H~ O_A Kevin Frederick r "­Administrator Water Quality Division

,S'-~'-\~ Date of Issuance

JSB/rm/13-0417

Todd Parfitt Director Department of Environmental Quality

Page20f3

(

Page 123: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

STATEMENT OF BASIS

1. Permit Number: 13-133

2. Application reviewed for compliance with the following regulations:

Chapters 3 and 12 of the Wyoming Water Quality Rules and Regulations.

3. Does the permit comply with all applicable regulations identified above?

4. Facilities include components not specifically covered by regulations and approval is based upon a deviation from applicable regulations in accordance with Section 5 of applicable regulations.

5. If Section 17 of Chapter 3 review is required indicate the basis for determining groundwater will be protected.

Public water supply wells are exempted from review by Chapter 3. Section 17

6. Documentation of Statement of Basis: The archive file for this permit includes adequate documentation of all sections of this Statement of Basis.

CERTIFICATION

The issuance of this permit is based upon a review of the application package submitted in accordance with the requirements of Chapter 3, Section 6, Wyoming Water Quality Rules and Regulations. This review was performed by James S. Brough, [email protected], Northwest District Engineer and completed on April 26, 2013. Permit issuance is recommended based upon statements, representations, and procedures presented in the permit application and supporting documents permit conditions, and the items identified in this "Statement of Basis."

cc: Kevin Boyce, P.G, Wyoming Water Development Commission, 6920 Yellowtail Rd., Cheyenne, WY 82002 Mark Stacy, P.G., Lidstone & Associates, Inc., 4025 Automation Way, Bldg. E., Fort Collins, CO 80525

Page 3 of 3

Page 124: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

('

(

(

Page 125: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Matthew H. Mead~ Governor

April 23, 2013

Department of Environmental Quality To protect, conserve and enhance· the quality of Wyoming's

environment for the benefit of current and fitfure generations.

NOTIFICATION OF COVERAGE

Dana Ehnle P.O.Box492 Encampment, WY 82325

Todd Parfitt, DirectoI'

RE: Town of Encampment: Blocks 109, 110, 119, & 120, Application No. 13-135, Carbon County

Reference: 07-286

Dear Mr. Ehnle:

The above application for coverage under General Pennit to Construct, Install, ModifY or Operate Extensions to or Modifications of Existing Public Water Supply Distribution Systems consisting of extending approximately 1750 lineal feet of water main and Existing Sewage Collection Systems consisting of extending approximately 2120 lineal feet of sMitary sewer main located in the Northwest Y4, Section 1, T14N, R84W, Carbon County, in accordance with Chapter 3, Section 9 ofthe Wyoming Water Quality Rules and Regulations has been reviewed and is hereby approved. You are authorized to construct, install or modifY the water distribution system in accordance with Chapter 12, Section 14 ofthc Water Quality Division Rules and RegUlations, the sewage collection system in accordance with Chapter 11, Section 9 of the Water Quality Division Rules and Regulations, and both systems in accordance with the general permit, the conditions listed helow, and the materials submitted in your application package. Your attention is directed to the maudatory reporting requirements outlined in Part V, Section 0 of the general permit. Additionally, the following project specific conditions also apply:

1. Where the water line crosses under sewer lines flow fill must be used from the water line to the top of the sewer line, extending a minimum distance of 5 fect each way from the centerline of the water line.

All construction, instal1ation, 01' modification allowed by this Notification of Coverage shall be completed by May 7, 2017.

Horsehler BuUding • 122 West 25th Street· Choyo.ne, WY 82002 • bttp:l1doq.,tate.wy.ll' ADMIN/olITRJi:ACn ABANDONED MINKS AIRQUAUTY INDUSl'lUIILSmNG LANDQUAL"lTY SOUD&HAZ. WASTE WATERQUAI,JTY

()01) 1':1M158 (307) Tl1·6145 FAX 717·16%2 FAX 171-6462

(307)771-1391 (307)177-736, FAX 171-5616 p'AX 777-5973

(307) 717-17% (301) 711-7752 (301) 777-77&1 MX771-:Wri4 flA:'01'1-5!Yl3 PAX 177-5913

Page 126: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

This Notice of Coverage is covered under the GeneralPermits on the Wyoming Department of Environmental Quality webpage. The General pelmits can be viewed at the following path:

http://deg.state.wy.us/wgd/www/P.ex,mitting/Pages/general permits.asp

Please reference Application No. 13-135 in any future correspondence.

If you have any questions, please contact me at either [email protected] or by phone at (307) 777-7088.

Sincerely,

~J~ Seili Tourney, P .E. Souilieast District Engineer Water Quality Division

SWT/rm/13-0359

Enclosures: Certificate of Completion form

co: IPS Jon Anderson, P.O. Box 595, Saratoga, Wyoming 82331 Doreen Harvey, ClerkITreasurer, Town of Encampment, P.O. Box 5, Encampment, WY

82325

(' ·1

(

Page 127: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality

Matthew H. Mead, Governor

July 23, 2013

Teton Science School clo Shawn Remis 700 Coyote Canyon Rd Jackson, WY 83001

To protect, conserve and enhance the quality of Wyoming's

environment for the benefit of current and foture generations.

RE: Teton Science School, WYS-039-0 12 Final Permit 13-136, Class V Septic System Permit Teton County, Wyoming

Dear Mr. Remis:

Todd Parfitt, Director

Attached please find one copy of the Class V septic system permit for the facility referenced above. Please be aware that this permit requires the installation of one down-gradient monitoring well t6 be installed within 6-months of the permit approval and a one-time baseline analysis of the well servicing Duplex G per Section H of your permit. This permit also requires semi-annual sampling and requires annual inspection and periodic pumping of the septic tanks per Section I. The report forms can be filled out using our on-line webform (Monitor Reports Link), or you may have the lab submit them using Electronic Data Deliverable (EDD) at the following site: http://gem.wqd.apps.deq.wyoming.gov/default.aspx. Please use the exact well names used in your pennit when reporting data to avoid any miscommunications. For your convenience, copies of the inspection forms are attached, you may use the paper forms to report your inspection and monitoring activities to WDEQ.

The underground injection control program was promulgated to prevent serious problems caused by direct discharges to the groundwater. Those problems included groundwater pollution leading to contamination in domestic water wells and serious health effects caused by exposures to toxic substances and water borne pathogens. Your cooperation with our program is sincerely appreciated.

If you have any questions please do not hesitate to contact me at the below referenced phone number or email.

Nicole Twing, P.G. Wyoming Department of Environmental Quality Project Geologist Water Quality Division Phone: (307) 777-8275 [email protected] NTlrml13-0680

Enclosure: Final Permit #13-136

cc: John Passehl, WDEQ

Hersc:hler Building' 122 West 25th Street· Cheyenne, WY 82002 . http://deq.state.wy.us AD~UN/OUTREACH

(307) 777-7758 FAX 777-768'2

ABANDO:..rED ""liNES (307) 777·6145 FAX 777-6462

AlRQUALlTY (307) 777·1391 FAX 777-5616

li'l'DUSTRIAl SITING 1307) 777-7369 FAX 777-5973

L."'-ND QUALITY SOLID & HAZ. WASTE (307) 777-7756 (307) 777·7752 FAX 777-5864 FAX 777.5973

WATER QUALITY (307) 777-7781 FAX 777-5973

Page 128: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(

(,

Page 129: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

STATE OF WYOMING DEPARTMENT OF ENVIRONMENTAL QUALITY

UNDERGROUND INJECTION CONTROL PERMIT ISSUED UNDER WYOMING WATER QUALITY RULES AND REGULATIONS

CHAPTER 16

CLASS V INJECTION WELL

( ) New ( ) Modified (X) Renewal

Permit Number: 13-136 Facility Number: WYS-039-012 State Subclass: 5E3 Previous Permit: 01-206

In compliance with the Wyoming Environmental Quality act (W.S. 35-11-101 through 1104, specifically 301(a)(i) through 301 (a)(iv), Laws 1973, Ch. 250, Section I) and Wyoming Water Quality Rules and Regulations, Chapter 16.

Applicant: Teton Science Schools 700 Coyote Canyon Road Jackson, WY 83001 (307) 734-3790

Teton Science Schools, hereafter referred to as the permittee, is authorized to continue operating the septic systems located in SE1I4 of the SE1I4 of Section 14, Township 41 North, Range 117 West, Teton County. The permittee is allowed to operate the facility according to the procedures, conditions of application 13-136, including the conditions and requirements of this permit. This permit shall become effective on date of issuance and is valid for ten (10) years.

Kevin Frederick, Administrator Water Quality Division Herschler Building, 122 West 25th Street Cheyeune, WY 82002

Todd Parfitt, Director Department of Environmental Quality Herschler Building, 122 West 25th Street Cheyenne, WY 82002

NT/rm113-0680

Page 1 of12

I Date •

Page 130: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Table of Contents (

A. Discharge Zone ................ ~ ........... " ................ ,.; .................. ; ............... ,.: ........................... 3

B. Well and Area of Review ................................................................................................ 3

C. Groundwater Classification ............................................................................................. 3

D. Authorized Operations ............ , ..... ;~ ................................................................................. 3

E. Hazardous Waste ................... " .... , ................................................................................... 4

F. ' Proper Operation and lv,[ainten,ance.,L .. ,; ......... ; ... , ... ; ................ ; .• : .................... ; ........... : .. .4 '., ' . " -- '

O. Entry and lruipection .............................................. " .. ; •... ~: ..... ; •. ; .... :.;;;; •. : ............ ; •.. ; ....... .4

H. Environmental Monitoring Program for Waters of the State ....... ;; ........ : ...................... ..4

I. Requirements for Monitoring Waters of the State ........................ ; ......... : •. ; ..................... 8

J. Test Procedures ................................................................................................................ 9

K.' . Records and' Reports: ....•...... : ...... : ... , ............................. : ..... : ............ ,;.; ............. ; ............... 9 ( 1. Permit Actions •. , ..... ;,: ... ; ...... ; ........ : .............. " ...... ; ...... :., ..... , .... ; .... : ............. ; .................... 9

M. Abandouinent. ................................................................................................................ 1 0

N;' Dutks:p{the Permittee ............................................................... Jl.: .... ..:J.::;.::.': .. ;; ......... 10

o. . '-- -,' --,

Signat~ries Requirement, ............................................................................. ; ................. 11

P. Noncompliance .................................................................................... : ......................... 11

Q. Permit Transfer .............................. , .............................. : ............................ ", ................. 12 _,:" \. \:, .. ,:;., __ i\_\~. . _,.: ,: _" '- t-:' f"~ .

PropertY Rights ................................................ : ............................................... ; ............... 12 R. 'i' ,

S. Severability ............................................................................. , ......... : .......... " ................ 12

Page 2 of12

Page 131: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

A. Discharge Zone The injection facility (sanitary leachfields) is authorized to inject an average of 2,970 gallons per day (calculated as 60% of maximum), and a maximum of 4,950 gallons per day combined total from four (4) sanitary leachfields servicing six (6) employee housing buildings and one (1) office/manager building (33 bedrooms total). The majority of wastewater is discharged to a mounded pressure-dosed septic system. The primary treated wastewater is injected into the sand and gravel alluvial aquifer adjacent to the Snake River. Depth to seasonally high groundwater in the vicinity of the leach field is approximately two (2) ft.

B. Well and Area of Review The injection wells authorized by this permit are located as follows:

SE Y. of the SE Y. of Section 14, Township 41 North, Range 117 West of the 6th Principal Meridian. Teton County.

The Area of Review is defined as a circular area of 360 acres with the injection facility located near its center. The Area of Review is based upon the following assumptions:

C. Gronndwater Classification

The groundwater in the alluvial aquifer beneath the permittee's property is classified as Class I according to Wyoming Water Quality Rules and Regulations, Chapter 8. This classification is made because the groundwater in this formation is currently being used for domestic purposes at nearby points of withdrawal.

Ground water of Class I is suitable for domestic use and shall not be degraded to make it unusable as a source of water for this purpose. An aquifer that contains less than 10,000 mg/L total. dissolved solids (and is not exempted) can be considered an underground source of drinking water.

D. Authorized Operations

The operator is authorized to inj ect at a pressure of no more than atmospheric pressure as measuredat-the leachfieldso -This pressure is controlled-by gravity-drainage and-is not required to be monitored. This does not preclude the operation of dosing pumps. The permittee is authorized to inj ect an average of 2,970 gallons per day and a maximum of 4,950 gallons per day. The wastewater is produced :from six (6) employee housing buildings and one (1) office/manager building (33 bedrooms total). The wastewater is injected into the unconfined

Page 3 of12

Page 132: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

alluvial aquifer adjacent to the Snake River. The wastewater is described as primary treated ( domestic sewage from four septic systems.

If additional sewage flows are added beyond those identified· in· the permit application, the permittee' must submit a revised application and receive a new permit prior to addition/modification of the leach field(s) or treatment system(s).

E. Hazardous Waste This permit does not allow for the injection of any hazardous waste as defined in 40 CFR 261.3 and in Wyoming Solid Waste Management Rules and Regulations, Chapter 2. Injection of any substance defined as a hazardous waste, whether hazardoUli . by listing or by characteristic is a violation of this permit. . .

F.' Pr~per Operation andM~int~nance The permittee shall take all reasonable steps to minimize or correct any adverse impact on the enviromnent resulting from noncompliance with this permit. The pennittee shall operate and. maintain all facilities and systems of tr~atrnentand control which areinstitlled or used by.the permittee to achieve cQmpliance with the conditions ,of the permit. Proper operation and maintenance includes: ,effectiyeper{onnance, adeqllatefuriQjl1gf 9pera.t?r. staffing and training, and laboratory .. an4pn?Ce~sC9ntr?ls; lrtclu~if1&~jfuro~riatP9fituitt ~ssuran~.eJ?roceq!1Ies. T!Ji:'C' s'---_____ _ provision requires the operation of back-up or auxiliary, facilities {)f similar systems only when necessary to achieveCoillpllance with theconditionsof,this peIillit.The injeftionwells covered by this permit shallmeeiall construction requiremepfs outlined inWyprning Water Quality Rules and Regulations; Chapters 11, 16,and 25.

The permittee isr~qui~~d to operate in accordance with.stateJ,l,wl1ts,.tepresentations and procedures presented inthecomptete pennitapplication and supporting docUlllents' as accepted and approved by the Administrator .. Any modifications which wiU),:esqlt in ,a yiolationpf permit conditions shall bereportedby SU1;lIn,iSsion of<\ ne"" or aJ1lende4p~I)l1it, apphcationand shall not be implemel1te(,luntil a: l1eW or,modifiedpein)jthas beenjss~~d., Injection mio aw'e111l1ay'not begin untilconstructioll is cOlPplete andthe p~rin.it isapproyed. '. . '., .

G. Entry and Inspection

The permittee sh1i11alto'Y the,i}.dtpinistrator(upon prrsentati(?llpfcredelltials and durjJ)g normal working hours) t(?epter the pr~nrises w~en;~il reguhitedf<\cjlitylslocated, or where re,cordsare kept under . thec~ndi~ons of.tpis. perl)1h' f:!ild .inspect. ~4pl1oiograpl1 th~. discharge<\ild related facilities, review andcopyrepocts and records required bythispeimit, collect fluid samples for. analysis, measure and record water levels, and perform any other function authorized by law or regulation. , ,.

H. Environment~i Monit~til1gPr6gramf()rWaters of the state GeneralRequirementS:' ..• . .

1. Samples and'm,easurements tak~n for the pllrpose ofiUomtoring sh~ll berepres~ntative of the monitored activity. AgroundwatersaJ1lp\eis considered repn;~entative of the aqpifer being monitored when the well has been pUrged to remove stagnant water prior to collection of a

Page 4 of12

(

Page 133: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

sample for laboratory analysis. Purging can be considered complete when a sufficient volume of water has been removed from the well and stabilization of select groundwater parameters has been achieved. It is important to record the circumstances surrounding each sample collection event at your facility. These records can help resolve analytical discrepancies. Both purging methods below shall be used prior to sample collection:

a. Purge by Volume Method Removal of a minimum of three casing volumes of water from the well should be completed prior to collecting a groundwater sample. Minimum purge volume can be calculated by the following equation:

Minimum Purge Volume = 3 * «Total Well Depth in feet - Depth to Water in feet) * Well Capacity) Where Well Capacity (gallons per foot) is based on well diameter:

2 inch well = 0.163 6 inch well = 1.47 4 inch well = 0.653 8 inch well = 2.61

b. Stabilization of Parameters Method Purging of groundwater until select field parameters have stabilized can be used to demonstrate that a representative sample was collected. Field parameters measured during purging should include at a minimum temperature, pH, and specific conductance. Field parameters should be measured after removal of every half casing volume of water.

Half Casing Volumc = 0.5 * «Total Well Depth in feet - Depth to Water in feet) * Well Capacity)

Where Well Capacity (gallons per foot) is based on well diameter: 2 inch well = 0.163 6 inch well = 1.47 4 inch well = 0.653 8 inch well = 2.61

A minimum of six (6) parameter measurements should be collected. If field parameters have not stabilized between the last three readings, purging and parameter measurement should continue until stabilization has been achieved. Stabilization can be demonstrated by a variance of no more than +/- 10% for temperature and specific conductance, and +/-0.2 standard units for pH.

2. The permittee shall retain records of all monitoring information including all calibration and maintenance records, copies of the reports required by this permit, and records of all data used to complete the application for this permit, for a period of at least three (3) years from the date of the sample measurement, report, or application. This period may be extended by request of the Administrator at any time.

3 . Tnejieririittee-slialluse electroniC data deliverable (EDD)feporting when reqUireo by the Administrator.

4. Records of monitoring information shall include:

PageS of12

Page 134: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

a. The date, exact place, and time of sampling or measurements; b. The initials or name(s) of the individual(s) who performed the .sampling or measurements; c. The date(s) analyses were performed; d. The time(s) analyses were initiated; . e. The initials or name(s) of the indivldual(s) who performed the analyses; f. References and written procedures for the analytical techniques or methods used; g. The results of such analyses, including the bench . sheets, instrument readouts, computer disks or tapes, etc., used to determine these results.

5. Monitoring must be conducted according to test procedures approved under 40 CFR Part 136, unless other test procedures have been specified in this permit.

6. The permittee shall retain all .records concerning thenatlJre and composition of injected fluids until five (5) years after completion of any specified plugging and abandonment procedures. The administrator may require the oWller/operator to deliver the records to the administrator at the conclusion of the retention period.

7. The permittee shalL report any. noncompliance which 'may endanger health or the environment within twenty-four (24) hours from the time. the operator becomes aware of the circumstances. The report should include:

(

a. Any monitoring or other information which indicates that any contaminant may cause an endangennent to ausable groundwater of the state;, .'. . (

b. Any noncompliance with a pennitconditionor malfunction of thedischarge (injection) system which may cause fluid migration irito or. between usable ground waters of the state;

c. A written submission shall be provided within five (5)days of the time the operator becomes aware of the circumstances. This written submission shall contain a description of the noncompliance and its cause; the period of noncompliance, includiug exact dates and times, and if the noncompliance has not been corrected; theanncipated .time it is expected to continue; anel steps taken or plaruied to,redjlce, eliminate, and prevent reoccurrenceof the noncompliance. .

8. The permittee shall report all instances of noncompliance not reported otherwise, at the time monitoring reports are submitted. . ..

9 .. The monitoring reports shall be sukmittedonformsproyidedbythe Department. Reports of compliance or noncompliance with; or any . progress reports on,jnterimand final requirements contained in any compliance schedule of thispemrit shall be.submitted no Jater than forty-five (45) days following each schedule date. . .

10. At least one monitor well is required to be installed at this facility within six (6) months of authorization of this permit. The permittee must obtain approval regarding the design and siting of the monitor well prior to installation. The new monitor well shall be constructed dOWll-gradient of the existing leachfields, and drilled until a saturated aquifer is encountered, ( :

Page 6 of12

Page 135: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

or to a depth of 250 feet, whichever depth is reached first. Based on well logs from nearby water wells, groundwater is encountered at approximately fifty (50) feet below ground surface.

11. The permittee's domestic supply well, servicing Duplex G which is upgradient of the leachfields, shall be sampled once to obtain baseline data. The parameters to be analyzed will be all those listed in Wyoming Water Quality Rules and Regulations Chapter 8; Table I except for radionuclides.

Page 7 of 12

Page 136: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

I. Requirements for Monitoring Waters of the State The groundwater in the receiving formation shall be sampled and the following parameters analyzed according to the schedule identified in Table 2. The following parameters shall be analyzed semi-annually and reported annually:

Monitor well #2 downgradient of

leach fields (to be installed within 6 months of permit

Septic Tanks'

Nitrate-Nitrite as N Semi-Annually V.I. -'-'..1 . .J I . _ (January-June Chloride 300.0; 300.1; or 4110 B, 4140 B, or I 250 mgIL 128 days Ino specified

and July. 353.2 4500-CI December) . . .) pH (standard umts; S.U.I.. 150.1 or 1502 4500-H+B 6.5-8.5 s.u.

Static Water Level Steel tape

Illeter 4,950

Annually Sludge depth in tank (ft) Visual

NOTES: . . 1 All applicable chemical concentrations in this permit are expressed as total (not dissolved).in mgIL unless otherwise noted.

'-'. Page 8 of12

,-,. ,-,

Page 137: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

3 The septic tanks serving the Teton Science School are to be inspected, at a minimum, annually and must be pumped as necessary based on sludge depth at bottom of the septic tanks, and at least once every five years. A copy of the invoice for pumping the tanks is to be included with the annual report. Sludge depth is not to exceed 24 inches in the septic tanks.

All annual reports are to be reported within forty-five (45) days of the last day of each year (February 15th

).

The upper control limits (UCL) in Table 2 cannot be exceeded in any sample. Exceedance of these values is a violation of this permit and shall require notification under Section K of this permit. If the UCL is exceeded in a sample, additional monitoring wells may be required to determine whether groundwater has been impacted and to delineate the nature and extent of any contamination resulting from operation of the permitted facility.

J. Test Procedures All samples and measurements taken for the purpose of monitoring shall be representative of the monitored activity. Ail samples taken shall include a trip blank of distilled water for each sampling date and a duplicate sample at least once per year. All required analyses shall be conducted in compliance with Wyoming Water Quality Rules and Regulations, Chapter 8, Section 7.

K. Records and Reports The permittee shall furnish to the Administrator within a specified time any information which the Administrator may request relating to the operation of the facility, including copies of records required to be kept by this permit. The permittee shall retain copies of alL records and reports required by this permit for a period of three (3) years following permanent well abandonment. Mer that time, those records shall be delivered to the Administrator for disposal or archive at his discretion. Confirmed noncompliance resulting in the migration of injected fluid into any zone outside the permitted receiver shall be reported to the Administrator within twenty-four (24) hours, and a written submission (via certified mail) shall be provided within five (5) days of the time the permittee becomes aware of the excursion. The written submission shall contain: a description of the noncompliance; the period of noncompliance, including exact dates and times, and if the noncompliance has not been controlled, the anticipated time it is expected to continue; and a list of the steps taken or planned to reduce, eliminate, and prevent the recurrence of the noncompliance. Confirmed noncompliance not already reported under this section shall be reported at the time monitoring reports are submitted. The reports shall contain the same information as required by the paragraph above. The permittee shall notifY the Administrator thirty (30) days in advance of any planned alteration, conversion, or abandonment of the well covered by this permit.

L;' PermiC1\cti6iis -'- . _.. ,.. __ ....

This permit is authorized for a period of ten (10) years. If the permittee wishes to continue injection after the expiration date of this permit he shall apply to the Administrator and obtain a new permit The application should be submitted at least 180 days before the expiration date of

Page 9 of12

Page 138: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

this permit. Under this permit, the Department may consider injection after the expiration date a violation of the permit. ( ,

It shall not be a defense for the permittee in an enforcemeniaction that it would be necessary to halt or reduce the permitted activity in,orderto maintain compliance with the.conditions of the permit. The filing of a request by the permittee, or at the instigation of the Administrator, for permit modification, revocation, termination; ot notification of planned changes or anticipated noncompliance shall not stay any condition of this permit.

After notice and opportunity for ahearing,a permit maybe modified, suspended or revoked in whole or part during its term for cause which inc1udes, but is not limited to any of the following:

1. Violation of this permit; or 2. Obtaining a permit by misrepresentation of facts in the application.

This permit will be reviewedafleast once, every five (5) years, and maybe reviewed more frequently. A permit may beI)1odifiedat anytinlC as triay berequired,inchlding for conformity with ,changes in iegulationsorstanilards whichoQcurafteFt~e permitwas issued. A permit may be modified in whole orpart in ord~rto apply more orless~tringentstandards; or prohibitions for toxic or other, substances present in the permittees discharge as maybe ordered by the Envirorffilental Quality Council.

M. Abandonment General Requirements:

1. The permittee shalIn6tifYtheadministratorat lellst thirty gO) days priorto abandomnent of

the facility. "",'.".,,< .' ",', ", ,',.',,",,' '" ", ,'," ',,' , "','""""""",,,',',. ,," ", 2. An abandorffilentreport, detailingthecompliancewithaband?rffilentprocedures outlined in

the original applicationf6rcoyerag~underthis permit; or describing any deviation~from the original plan', shallbesubI)1itted,as soon as prlfcticabkllfterabimdorffilent., The,abandorffilent shall includereciamationofthe .\Vellslte. ,,' '/, ", ," ", ",..

3. Injection wells coveredby'thlspennit,shallbe abandoned in accordance with· Wyoming Water QUlllity RuleSandRegUIations,C;hapter 16, $ectl()n 12; " , '

N. Duties ofthePermitt~e

(

The permitteeshallgiy~advance nOtice to the Ac!nrinistratoi as soon asp()ssible of~y plarmed physical alterati()n oradditioris;otherth!U1!luthm;izedoperation,andI)1aintenance, to the permitted facility a:ndreceiveallthorizationprior to implementing the proposed alternation or addition. ,The pefI)1ittee shall furnish theAdIp.ii1i~tratorwithinareasop.able timeanyir1ormation which the Administrator may request to dett?rmine whether causet?xistsfor I)1odifying, revoking, or reissuing, • or, terminating this permit; orto determine compliance with this permit; and to furnish to the Administrator upon request,copies of records required to be kept by this permit. Any modification whichmayresultin a violation of a permit condition shall be reported to the Administrator, and any modificationthatwiU result in ayiolatiollofanypeJ:lllit conditions shall . be reported to the AdministratOl)hrough the submission of a new or.arnendeci permit'application. ( The permittee shall repOl:t· all instances where he bec()mes aware that he failed to submit any

Page 10 of12

Page 139: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

relevant facts in the permit application, or where he submitted incorrect information in a permit application or in any report to the Administrator, and shall promptly submit such facts or information.

If any cultural materials are discovered during construction, work in the area should halt immediately. The Administrator and the Wyoming State Historic Preservation Office shall be contacted (777-7697) and the materials shall be evaluated by an archaeologist or historian meeting the Secretary of the Interior's Professional Qualification Standards (48 FR 22716, Sept. 1983).

O. Signatories Requirement All reports filed in conjunction with this permit shall contain the following certification:

"I certii'y, under penalty of law that this document and all attaclnnents were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility offine and imprisonment for knowing violations."

All reports required by this permit and other requested information shall be signed as follows:

For a corporation - by a principal executive officer of at least the level ofvice-presidcnt; . For a partnership or sole proprietorship - by a general partner or the proprietor, respectively;

For a municipality, state, federal, or other public agency - by either a principal executive officer or ranking elected official; or

By a duly authorized representative for any of the above. A person is a duly authorized representative only if:

I. The authorization is made in writing by one of the prescribed principals; 2. The authorization specifies either an individual or position having responsibility for the

overall operation of the regulated facility or activity; and 3. The written authorization is submitted to the Administrator.

If an authorization is no longer accurate because a different individual or position has responsibility for the overall operation of the facility, a new authorization must be submitted to the Administrator prior to or together with any reports or information, to be signed by the new

. alillionzearepresentauve. - - -- . - '.. . " .. _. ,

P. Noncompliance

The permittee shall comply with all conditions of the permit. Any permit noncompliance constitutes a violation of Wyoming Water Quality Rules and Regulations, Chapter 16 and is

Page 11 of 12,

Page 140: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

grounds for enforcement action, permit termination, revocation, or modification. Conformed (C noncompliance resulting in an excursion shall be reported to the Administrator orally within twenty-four (24) hours, and a written submission shall be provided within five (5) days of the time the permittee becomes aware of the excursion. The written report shall contain the sections specified in Section K of this permit; Any permitnoncompliance constitutes a violation of this permit.

The filing of any request by the permittee for a permit modification, revocation and reissuance, or termination, or a notification of planned changes or anticipated noncompliance, does not stay any permit condition.

Q. Permit Transfer Any transfer of this permit shall be accomplished by the submis'sion of the proper, forms for permit transfer to theAdministrator.Transferofthis penIlitnmstfirstbe approved by ,the Administrator and the Director. No transfer shall be approved unless the proposed permittee agrees to bring al1yand all noncompliance issues into compliance with this permit. ,The permittee is alone responsible for the operation of the facility covered by this permit. Sale of the ' facility and subsequent operation of this facility by anotheris a violation of this permit uuless a transfer of this permit has first been accomplished.

R. Property Rights This permit 'does not convey any properly rights ,Of any sort or any exclusive privilege. This permit does not authorize injury to private property or any invasion of personal rights, nor any (' infringement of federal; state, or IQcallaws or regulations.' , ', j

S. Severability Nothing in this permit shall be construed to preclude the institution of any legal action or to relieve the permittee from' any responsibilities; liabilities, orpenhltiesestablishedpUrsuant to any applicable state law or regulation. '

-End of Permit-

Page 12 of12

(i

Page 141: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

PERMIT NO.13-137

WYOMING DEPARTMENT OF ENVIRONMENTAL QUALITY WATER QUALITY DIVISION PERMITTO CONSTRUCT

REDUNDANT BAG FILTRATION PWS WY5600291

This permit hereby authorizes the applicant:

Dave Johnston Generating Station 1591 Tank Farm Road Glenrock, WY, 82637

to construct, install or modify one redundant bag filtration unit according to the procedures and conditions of the application number '13-137. The facility is located in NE 1/4 of Section 18, T33N R74W; Converse County, in the State of Wyoming. All construction, installation, or modification allowed by this permit shall be completed May 16, 2015.

The issuance of this permit confirms that the Wyoming Department of Environmental Quality (DEQ) has evaluated the application submitted by the permittee and determined that it meets minimum applicable construction and design standards. The compliance with construction standards and the operation and maintenance of the facility to meet the engineer's design are the responsibility of the permittee, owner, and operator.

Granting this permit does not imply that DEQ guarantees or ensures that the permitted facility, when constructed, will meet applicable discharge permit conditions or other effluent or operation,)1 requirements. Compliance with discharge standards remains the responsibility ofth<;lpermittee ..

Nothing in this permit constitutes an endorsement by DEQ of the construction or the design of the facility described herein. This permit verifies only that the submitted application meets the design and construction standards imposed by Wyoming statutes, rules and regulations. The DEQ assumes no liability for, and does not in any way guarantee or warrant the performance or operation of the permitted facility. The permittee, owner and operator are solely responsible for any liability arising from the construction or operation of the permitted facility. By issuing this permit, the State of Wyoming does not waive its sovereign immunity.

The permittee shall allow authorized representatives from DEQ to enter and inspect any property, premise or place on or at which the facility is located or is being constructed or installed for the purpose of investigating actual or potential sources of water pollution, and for determining compliance or non-compliance with any rules, regulations, standards, permits or orders.

Nothing in this permit shall be construed to preclude the institution of any legal action or other proceeding to enforce any applicable provision of law or rules and regulations. It is the duty of the permittee, owner and operator to comply with all applicable federal, state and local laws or regulations in the exercise of its activities authorized by this permit.

The issuance of this permit does not convey any property rights in either real or personal property or any invasion of personal rights, nor any infringement of federal, state or local laws or regulations.

Page 142: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

The permittee shall construct and operate the permitted facility in accordance with the statements, representations, procedures, terms and conditions, of the permit application, supporting documents and permit. This permit does not reli~ve the permittee from any duty to obtain any (, other permit or authorization that may be required by any provision of federal, state or local laws,

In carrying out its activities authorized by this permit, the permittee, owner and operator shall comply with all of the following permit conditions:

1 The applicant will provide immediate oral or written notice to the Southeast District, Water Quality Division, Herschler Building 4 West, Cheyenne, WY, 82002, Phone 307-777-7088, FAX 307-777-7610, in accordance with the provisions of Section 11, Chapter 3, Wyoming Water Quality Rules and Regulations of any changes or modifications which are not consistent with the terms and conditions of this permit.

2, Within sixty days of completion of construction of the authorized facility, the applicant will submit to the Southeast District, Water Quality Division, Herschler Building 4 West, Cheyenne, WY, 82002 a certification of completion signed by the Engineer of Record or the owner. A form titled "Certificate of Completion" has been provided and must be completely filled out.

3. The review and approval of this permit is based upon the items identified in the attached "Statement of Basis""

AUTHORIZED BY:

Kevin Frederick Administrator Water Quality Division

Date of Issuance ':-=-) _. ,;to - \ C;)_)

SWTlrm/13-0456

Todd Parfitt Director Department of Environmental Quality

(

(

Page 143: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

STATEMENT OF BASIS

1. Permit Number: 13-137

2. This application was reviewed for compliance with the applicable regulations;

Chapters 3. 12

3. Does the permit comply with all applicable regulations identified above?

4. A review to determine groundwater impacts in accordance with Section 17, Chapter 3 was not required.

Public water supplies are exempted from review by Chapter 3, Section 17.

5. Documentation of Statement of Basis: The archive file for this permit includes adequate documentation of all sections of this Statement of Basis.

CERTIFICATION

The issuance of this permit is based upon a review of the application package submitted in accordance with the requirements of Chapter 3, Section 6, Wyoming Water Quality Rules and Regulations. This review was performed by Seth Tourney, Southeast District Engineer, Water and Wastewater Section, Wyoming Department of Environmental Quality /Water Quality Division, and completed on May 17, 2013. Permit issuance is recommended based upon statements, representations, and procedures presented in the permit application and supporting documents, permit conditions, and the items identified in this "Statement of Basis."

Page 144: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

('

(

(

Page 145: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Motthaw H. Me.d, GOV6mor

June 20, 2013

Don Behnke DSJ Propelties, LLC. 223 Hoadley Rd. Gillette, WY 82718

Department of Environmental Quality To protect, consetve, and enhance the quality of J1ry'oming'S

anvlronment for the benefit of ClJrrent and fUtuf9 generations.

152 N. Durbin St., Suite 100 ' Casper, WY 82601 . (307) 473-3450

NOTIFICATION OF COVERAGE

RE: DSJ Properties, LLC. Small Wastewater System Application No. 13-138, Campbell County

Dear Mr. Behnke:

Todd P.rfIt~ Director

The above application for coverage under General Permit to Construct, Install, Modify or Operate a Small Wastewater Facility consisting of a 1,000 gallon J&o Precast concrete septic tank discharging into one chambered trench ofthree Biodiffuser ARC 36 chambers, for a commercial building located in the SEY. NEY., Section 21, Township 49 N, Range 71 W, Campbell COlUlty, in accordance with Chapter 3, Section 9 of the Wyoming Water Quality Rules and Regulations has been reviewed and is hereby approved. You are authorized to construct, install, or modify the facility in accordance with Chapter 25 of the Water Quality Division Rules and Regulations, the general permit, and the materials submitted in your application package. Your attention is directed to the mandatory reporting requirements outlined in Part V, Section 0 of the general permit. AlJ constntction, installation, or modificatiou allowed by this Notification of Coverage shall be completed by December 31, 2014.

This Notification of Coverage is covel'ed under the General Permits on the Wyoming Department of Environmental Quality webpage:

http://deq.state.wy.us/wqd/www/Permitting/Pages/general permits.asp

Additionally, the following permit condition applies: 1. Cleanouts are required every 100 feet and at all changes in direction 22.5 degrees and greater.

If you have any questions, please contact me at 307-473-3478.

Sincerely,

ct<~l~ Karen L. Farley, P.E. NE District Engineer WDEQ/WQD

cc: IPS, Cheyenne WDEQ Casper File Keith Bowar, Campbell Counly Public Works, 500 S. Gillette Ave., Suite 1500, Gillette, WY 82716 Bret Wolz, P.E., 445 Sinclair Street, Gillette, WY 82718

Cbe~cnno 122 West 25' Street &2002

(307) 777-7937

Lander 510 MeadowvIew DrIve 82520

(307) 332-3144

Sheridan 2100 W. 5'h Street 82801

(307) 673-9337

Page 146: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(

(\

Page 147: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality To protect, conserve, and enhance the quality of Wyoming's

environment for the benefit of current and future generations.

Matthew H. Mead, Governor 152 N. Durbin St., Suite 100 . Casper, WY 82601 . (307) 473·3450

June 3, 2013

Jacob 1. Wright, P.E. Nelson Engineering P.O. Box 1004 Buffalo, WY 82834

RE: King Lane Water Main Extension, Johnson County, WY WDEQ Application #13·139

Dear Mr. Wright:

Todd Parfitt, Director

We have completed our second review of the application originally received on April 15, 2013. Attached you will find a summary of the review comments. Please provide the information requested as soon as possible. Please feel free to contact me at (307) 473·3478 should you have any questions related to these comments or the application and review process.

Sincerely,

j)~j.~ Karen 1. Farley, P.E. Northeast District Engineer WDEQ/WQD

Attachments: WDEQ Comments

cc: IPS WDEQFiIe

Che~enne 122 West 25' Street 82002

(307) 777·7937

Lander 510 Meadowview Drive 82520

(307) 332·3144

Sheridan 2100 W. 5'h Street 82801

(307) 673·9337

Page 148: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

( (

('

(

(J

Page 149: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

REVIEW OF PLANS & SPECIFICATIONS WYOMING DEPARTMENT OF ENVIRONMENTAL QUALITY

WATER QUALITY DIVISION 152 North Durbin Street, Suite 100

Casper, Wyoming 82601 Phone (307) 473-3465

PROJECT: King Lane Water Main Extension

LOCATION: Johnson County

ENGINEER: Nelson Engineering

APPLICANT: Johnson County

WATER QUALITY DIVISION APPLICATION NUMBER: 13-139

DATE ON PROPOSAL/PLANS/REPORT: March 2013

DATE RECEIVED BY DEQ: April 15,2013

DATE OF THIS REVIEW: June 3, 2013

WDEQ REVIEWER: Karen Farley, P.E.

ACTION: NOT AUTHORIZED FOR CONSTRUCTION. In accordance with Chapter 3, Section 14 (a), Wyoming Water Quality Rules and Regulations (WWQRR), the application is denied because it is incomplete and/or contains errors. Please address the comments outlined below and submit the requested information/clarifications in order that the application process may be completed in accordance with Chapter 3, Section 9 of the WWQRR. If the applicant fails to provide the requested information within six months, the incomplete application shall be returned. This review may not inc1mle all deficiencies and shall not be construed as a complete comprehensive list.

WDEQ COMMENTS

1) The proposed water line will need to be connected onto the main line with a tee. We are not aware of any PVC wyes that conform to A WW A C907 that are used for pressurized water mains. If one has recently been developed for use, please let us know.

2

Page 150: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(:

(i

Page 151: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Matthew H. Mead, Governor

June 12, 2013

Scott Pehringer 310 Railroad Avenue Buffalo, WY 82834

Department of Environmental Quality To protee, con89/Ve, al1d enhance the quality of Wyoming s envlromnent for the benem of current al1d futurtJ generaUons.

152 N. Durbin St., Suite 100 . Casper, WY 82601 . (307) 473-3450

NOTIFICATION OF COVERAGE

. RE: King Lane Water Main Extension, Buffalo, WY WDEQ Application No. 13-139, Johnson Connty

Dear Mr. Pehringer:

Todd Partlll. Dlreclor

The above appIicationfor coverage under General Permit to Construct, rn8tal~ ModifY or Operate Extensions to or Modifications of Existing Water Supply Distribution Systems, consisting of the installation of approximately 525 lineal feet of 8" PVC water line, to provide services and fire suppression for Johnson County facilities, located in the SE '/., SW '14, of Section 26, Township 51 North, Range 82 West, a Resubdivision bf Anderson Addition, Buffalo, WY, in accordance with Chapter 3, Section 9 of the Wyoming Water Quality Rules and Regulations has been reviewed and is hereby approved. You are authorized to construct, instail, or modify the facility in accordance with Chapter 12 of the Water Quality Division Rules and Regulations, the general permit, and the materials submitted in your application package. Your attention is directed to the mandatory reporting requirements outlined in Part V, Section 0 of the general permit. All constmction, installation, or modification allowed by this Notification of Coverage shall be completed by December 31, 2014.

This Notification of Coverage is covered under the General Permits on the Wyoming Department of Environmental Quality webpage:

http://deq.state.wy.usiwqd/www/Permitting/Pagesigeneral permits.asp

If you have any questions, please conl<~ct me at 307-473-3478.

Sincereiy,

!::;:;;,~. NE District Engineer WDEQ/WQD

cc: IPS, Cheyenne WDEQ Casper File Les Hook, 46 North Main Street, Buffalo, WY 82834 Jacob L. Wright, P.E., Nelson Engineering, P.O. Box 1004, Buffalo, WY 82834

Chei.enne 122 West 25" Street 82002

(307) 777·7937

Lander 510 Meadowview Drive 82520

(307) 332·3144

Shorldan 2100 W. 5'" Street 82801

(307) 673·9337

Page 152: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

( (

(

(

(!

Page 153: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

WYOMING DEPARTMENT OF ENVIRONMENTAL QUALITY WATER QUALITY DIVISION

PERMIT TO CONSTRUCT

PERMIT NO. 13-140 REFERENCE PERMIT NO. N/A

Wright Water and Sewer District- RJ-7 1 MG Tank Project, PWS No. 5600136

This permit hereby authorizes the applicant:

Joseph Johnson Wright Water and Sewer District

P.O. Box 549 Wright. WY 82732

to constmct, install or modifY a new 1,000,000 gallon potable water storage tank according to the procedures and conditions of the application number 13-140. The facility is located in Section 3, Township 43 North, Range 72 West, further located in Wright, Wyoming. All construction, installation, or modification allowed by this permit shall be completed by December 31, 2016.

The issuance of this permit confirms that the Wyoming Department of Environmental Quality (DEQ) has evaluated the application submitted by the permittee and determined that it meets minimum applicable construction and design standards. The compliance with construction standards and the operation and maintenance of the facility to meet the engineers design are the responsibility of the pennittee, owner, and operator.

Granting this permit does not imply that DEQ guarantees or ensures that the permitted facility, when constructed, will meet applicable permit conditions or other operational requirements. Compliance with all applicable standards remains the responsibility of the pennittee.

Nothing in this permit constitutes an endorsement by DEQ of the construction or the design of the facility described herein. This permit verifies. only that the submitted application meets the designand construction standards imposed by Wyoming statutes, rules and regulations. The DEQ assumes no liability for, and doesrlot in any way guarantee or warrant the performance or operation of the permitted facility. The permittee, owner and operator are solely responsible for any liability arising from the construction or operation of the permitted facility. By issuing this permit, the State of Wyoming does not waive its sovereign immunity.

The permittee shall allow authorized representatives from DEQ to enter and inspect any property, premise or place on or at which the facility is located or is being constructed or installed for the purpose of investigating actual or potential sources of water pollution, and for determining compliance or non-compliance with any rules, regulations, standards, permits or orders.

Nothing in this permit shall be construed to preclude the institution of any legal action or other proceeding to enforce any applicable provision of law or rules and regulations. It is the duty of the permittee, owner and operator to comply with all applicable federal, state and local laws or regulations in the exercise of its activities authorized by this permit. The issuance of this pennit does not convey any property rights in either real or personal property or any invasion of personal rights, nor any infringement of federal, state or local laws or regulations.

The permittee shall construct and operate the permitted facility in accordance with the statements, representations, procedures, terms and conditions of the permit application, supporting documents and permit. This permit does

Page 154: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

not relieve the permittee from any duty to obtain any other pennit or authorization that may be required by any provision of federal, state or local laws.

In carrying out its activities authorized by this permit, the permittee, owner and operator shall comply with all of ( the following permit conditions:

lof5

20f5

3 of5

40f5

The applicant will provide immediate oral or written notice to the Northeast District, Water Quality Division, 152 North Durbin, Suite 100, Casper, WY, 82601, Phone 307-473-3465, FAX 307-473-3458, in accordance with the provisions of Section 11, Chapter 3, Wyoming Water Quality Rules and Regulations of any changes or modifications which are not consistent with the terms and conditions of this peJmit.

Within sixty days of completion of construction of the authorized facility, the applicant will submit to the Northeast District, Water Quality Division, 152 North Durbin, Suite 100, Casper, WY,82601 a certification of completion signed by the Engineer of Record or the owner. A form titled "Certificate of Completion" has been provided and must be completely filled out.

Within thirty days of completion of construction of the authorized facility, the Engineer of Record will submit two (2) complete copies of the Operation and Maintenance Manuals to the Northeast District, Water Quality Division, 152 North Durbin, Suite 100, Casper, WY 82601.

The review and approval of this permit is based upon the items identified in tile attached "Statement of Basis".

5 of 5 Construction of the storage tanic will not commence until the WDEQ/WQD Northeast District Office has been provided, and has approved, the storage tank structural and foundation designs sealed by a Wyoming professional engineer.

AUTHORIZED BY:

Kevin Frederick Administrator Water Quality Division

Date ofIssuance

JRV/nnl13-1003

Todd Parfitt Director Department of Environmental Quality

cc: Dave Meyers, P.E., HDREngineering, Inc., P.O. Box 457, Gillette, WY 82717 Jolm Gillis, PhD, EPA Region 8, 1595 Wynkoop Street, Denver, CO 80202-1129

(

(

Page 155: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

STATEMENT OF BASIS

I. Permit Number: 13-140

2. Application reviewed for compliance with the following applicable regulations:

POLICIES 14.13.2 AND 14.13.3, AS WELL AS CHAPTER 3 AND CHAPTER 12 OF THE WYOMING WATER QUALITY RULES AND REGULATIONS

3. Does the permit comply with all applicable regulations identified above?

YES

4. Facilities include components not specifically covered or differing from applicable regulations and approval is based upon a deviation in accordance with Section 5.

N/A

5. A review to determine groundwater impacts in accordance with Section 17, Chapter 3 is not required.

6. Documentation of Statement of Basis: The archive file for this permit includes adequate documentation of all sections of this Statement of Basis.

CERTIFICATION

The issuance of this permit is based npon a review of the application package submitted in accordance with the requirements of Chapter 3, Section 6, Wyoming Water Quality Rules and Regulations. This review was perfonned by Jason Vreeland, P.I:i., and completed on October 11, 2013. Permit issuance is recommended based upon .statements, representations, and procedures presented in the permit application and supporting documents, permit conditious, and the items identified in this "Statement of Basis."

Page 156: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(.

(, ...

(

Page 157: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Depal Lment of Environmental :Quality

To protect, conserve, and enhance the quality of Wyoming's

environment for the beneOt of current and future generetions.

Matthew H. Mead, Governor 152 N. Durbin St., Suite 100 ' Casper, WY 82601 ' (307) 473-3450

May 22, 2013

Dave Meyers, P.E. HDR Engineering, Inc. P.O. Box457 Gillette, WY 82717

RE: Wright Water and Sewer District - RJ-7 ! MG Tank Project Location: NE v., Section 3, Township 43N, Range nw WDEQ Application #13-140

Dear Mr. Meyers:

John Corra, Director

We have completed our review of the permit application submitted on April!!, 2013. Attached you will find a summary of the review comments. Please provide the information requested as soon as possible. Please feel free to contact me at (307) 473-3469 should you have any questions related to these comments or the application and review process.

Sincerely,

-7?-2r/ Jason Vreeland, P.E. Assistant Northeast District Engineer WDEQ/WQD

Attachments: WDEQ Comments

cc: IPS WDEQ File

Lander Che1enne 122 West 2S' Street 82002

(307) 777-7937 510 Meadowview Drive 82520

(307) 332-3144

Sheridan 2100 W. 5th Street 82801

(307) 673-9337

Page 158: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

( (

(

(

Page 159: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

REVIEW OF PLANS & SPECIFICATIONS WYOMING DEPARTMENT OF ENVIRONMENTAL QUALITY

WATER QUALITY DIVISION 152 North Durbin Street, Suite 100

Casper, Wyoming 82601 Phone (307) 473-3465

PROJECT: Wright Water and Sewer District - RJ-7 1 MG Tank Project

LOCATION: Wright, Wyoming

ENGINEER: HDR Engineering, Inc.

APPLICANT: Wright Water and Sewer District

WATER QUALITY DIVISION APPLICATION NUMBER: 13-140

DATE ON PROPOSALIPLANSIREPORT: Apri19, 2013

DATE RECEIVED BY DEQ: April 11, 2013

DATE OF THIS REVIEW: May 22, 2013

WDEQ REVIEWER: Jason Vreeland, P.E.

ACTION: NOT AUTHORIZED FOR CONSTRUCTION. In accordance with Chapter 3, Section 14 (a), Wyoming Water Quality Rules and Regulations (WWQRR), the application is denied because it is incomplete andlor contains errors. Please address the comments outlined below and submit the requested information/clarifications in order that the application process may be completed in accordance with Chapter 3, Section 9 of the WWQRR. If the applicant fails to provide the requested information within six months, the incomplete application shall be returned. This review may not include all deficiencies and shall not be construed as a complete comprehensive list.

WDEQ COMMENTS

1) WDEQ Policy 14.13.3 - The design report must demonstrate that the storage will be operated for a minimum of 10% daily fill at all times including during the month of minimum use. Additionally, the average age of water must be provided. Ifthe average age of water is greater than two days the storage must be operated so that a minimum 25% fill occurs each time pumping is initiated with a minimum inlet velocity ofl 0 ft/s. If this is not possible, the storage must have designed passive or active mixing.

2) Chapter 12, Section 13(a)(vi) - The formula used to calculate the capacity of the overflow doesn't appear to take into account the restriction in flow due to the orifice. Additionally, the drain system should be evaluated for the capacity ofthe 12" line after the manhole.

2

Page 160: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

( ( . \ ,

(\

(

(,

Page 161: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

3) Chapter 12, Section 13 (a)(vi) - The overflow pipe doesn't appear to designed in the access tube. WWQRR require overflow pipes to be located in the access tube. Please address.

4) Chapter 12, Section 1 3 (a)(v) - The overflow/drain pipe appears to enter the maohole near the bottom of the manhole. WDEQ Policy 14.13.2 requires an air gap of2 feet with either a check valve (Tideflex is not in the policy) or screen.

5) The plan set notes Class S slurry is to be used to backfill between pipes. Is there a special provision or specification for this type of slurry or is this the same as cement treated backfill in theWPWSS?

6) The outlet structure to be constructed under the RJ -7 well completion application which is referenced on the plan set, doesn't appear to be designed to connect the 12" drain from the tanks. Please address.

3

Page 162: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

( l",

(,

(,

Page 163: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality

To protect! conserve and enhance the quality of Wyoming's environment for the bendit of Cllmnt and future generations.

May 23, 2013

Eugene D. Nlnnle Town of Pinedale P.O. Box 709 Pinedale, WY 82941

NOTIFICATION OF COVERAGE

Todd Drrector

RE: Pinedale .. Water Metering Improvements Project - Permit Number 13-141, Sections 32,33,34, T34N, R109W, and Sections 3,4,5, T33N, R109W, (Original Block 4, Lots 1-5, Town Hall Building) Sublette County

Dear Mr. Nlnnle:

The above application lor coverage under General Penmlt to Construct for the modification of a Publlc Waler Supply System consisting of 895 new water meters, the replacement of 27 existing meters with new motors and the installation of an Automated Moter Reading Data Collection and Communication System in accordance with Chapter 3, Section 7 and Chapter 12, Section 14 of the Wyoming Water Quality Rtlles and Regulations has been reviewed and is hereby approved. You afe authorized to construe!, the facilltios in accordance with the general permits and the materials sUbmittod in your application package. Your attention is directed to the mandatory rePorting requirements outlined in Part V, Sactlon 0 of the General Permit. These Genersl Permit requiroments carr be downloaded from tho Wyoming Department of Environmental Quality webpage. The General Permits can be found under the Water Quality Division Water and Wastewater Program, Engineering and Technical Services at: l:illR:1Ideg.state.wy.us!wqd/vywvyjpermitting/Pages/geoeraJ permits.as.!?

If you have any questions, please contact me at 307-332-3144.

Mark Baron, P.E. Southwest District Enginoer Water Quality Division

PDF to Cheyenne Bemard E. Poppenga, P.E., Stantec ConsullingServices, Inc., 2000 S. Colorado Blvd" Suilo 2· 300, Denver, CO 80222

Page 1 of 1

lander Field OffiCI! • 510 liIleadowview • I...a""e" WY 82520 • ABANDONED I\JUNES

1307) 332·,OB5 FAX "'~2·7ne

f~!RQUALnY (301) 332·6755 FAX 332-7726

LAN~ QUAliTY 1307) 332·3047 FAX 332-7726

SOLID I< HAZARDOUs WASTE (307) :1:l2,6924 t'AX :,32·7726

WAT!!R QUALITY (:107) 332,1144 fAX 332.7776

Page 164: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

('

(.

Page 165: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality

To protect, conserve and enhance the quality of Wyoming's environment for the benefit of current and future generations.

Matt Mead, Governor

May1,2013

M&R Development Rich Gibbs P.O. Box3151 Cheyenne, WY 82901

NOTIFICATION OF COVERAGE

Todd ParAn, Director

RE: Rock Springs - City's Edge Subdivision - Water and Sewer Main Extensions - Permit Number 13-142, NW y., Section 33,T19N,R105W,Sweetwater County

Dear Mr. Gibbs:

The above application for coverage under General Permit to Construct for the extension of a Public Water Supply System consisting of about 1293 linear feet (LF) of 8-inch PVC water main and the extension of a Public Sewage Collection System consisting of about 2500 LF of 8-inch sewer main to serve a 38 lot residential subdivision in accordance with Chapter 3, Section 7, Chapter 12, Section 14 and Chapter 11, Section 9 of the Wyoming Water Quality Rules and Regulations has been reviewed and is hereby approved: You are authorized to construct, the facilities in accordance with the general permits and the materials submitted in your application package. Your attention is directed to the mandatory reporting requirements outlined in Part V, Section 0 of the General Permit. These General Permit requirements can be downloaded from the Wyoming Department of Environmental Quality webpage. The General Permits can be

. found under the Water Quality Division Water and Wastewater Program, Engineering and Technical Services at : http://deg.state.wy.us/wgd/www/Permitting/Pages/general permits.asp

If you have any questions, please contact me at 307-332-3144. Sincerely, D c/lrkA. ~. Mark Baron, P .E. Southwest District Engineer Water Quality Division

PDF to Cheyenne Shawn M. Arnoldi, P.E., Choice Engineering Services, Inc.,404 N. Street, Suite 201, Rock Springs, WY 82901

Page 1 of l'

Lander Field Office' 510 Meadowview Drive' Lander, WY 82520 • http://deq.state.wy.us ABANOONE:O MINES

(307) 332-5085 . FAX 332-7726

AIR qUALITY (30n 332-6755 l'AX 332-7726

LANO QUALITY (307) 332-3047 FAX 332-7726

SOLID & HAZARDOUS WASTE (307) 332-6924 FAX 332-7726

WATE:R QUALllY (307) 332.3144 FAX 332-7726

Page 166: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(:

(

()

Page 167: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality To protect, conS8IVe, and enhance the quality of Wyoming's

environment for the benefit of current and future generations.

Mallhow H. Me.d, Qo,emor 152 N. Durbin St., Suite 100 . Casper, WY 82601 • (307) 473·3450

June 19,2013

Mayor Steve Blakeman Town of Moorcroft P.O. Box 70 Moorcroft, WY 82721

NOTIFICATION OF COVERAGE

RE: South Belle Fourche Water Main Replacement, Town of Moorcroft, WY ApplicatiollNo. 13-143, Crool, County

Deal' Mayor Blakeman:

Todd Parfitt, Olraotor

The above application ror coverage under General Permit to Constmct, Install, Modify or Operate Extensions to or Modifications of Existing Water Supply Distribution Systems consisting of the replacement of approximately 1,190 lineal feet oi8 inch PVC water main, 20 water services, 3 fire hydrants, and other associated items, located in Section 6, Township 49N, Range 67W, Crook County, in accordance with Chapter 3, Section 9 of the Wyoming Water Quality Rules and Regnlalions has been reviewed and is hereby approved. You al'e authorized to construct, install, or modify the facility ill accordance with Cbapter 12 oftile Water Quality Division Rules and Regulations, the general. permit, and the materials submitted ill your application package. Your attention is directed to the mandatory reporting requirements outlined in Part V, Section 0 of the general permit. All constrcctioll, installation, or modification allowed by this Notification of Coverage shall bc completed by December 31, 2015.

This Notitication ofCov"rage is cove,'ed under the General Pemlits on the Wyoming Department ofEl1virollmental Quality webpage:

l.ll1p:lldeQ,state,wy,tlS/wq9fwww/Perll1itting/Pages/~enel'al penllits.asp

If you have lIllY questions, please contaetme at 307-473-3478.

Sincerely,

~fMw,i.~ Karen L. Farley, P.E. NE Distl'ict Engineer WDEQIWQD

CC: IPS, Cheyenne WDEQ Casper File Bill A. Carsoll, P,E., HDR Engineering, Inc., 1',0. Box 457, Gillette, WY 82717

Chel'enne 122 West 25' Street 82002

(307) 777-7937

LOlIder 510 MeadowvIew Drive 82520

(307) 332-3144

Sheridan 2100 W. 5" Streot 82801

(301) 673·9337

Page 168: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(\

(

(!

Page 169: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

STATE OF WYOMING DEPARTMENT OF ENVIRONMENTAL QUALITY

UNDERGROUND INJECTION CONTROL PERMIT ISSUED UNDER WYOMING WATER QUALITY RULES AND REGULATIONS

CHAPTER 16

CLASS V INJECTION WELL

( ) ( ) (X)

New Modified Renewal

Pennit Number: 13-144 Facility Number: WYS-029-118 State Subclass: 5E4 Previous Pennit Number: 03-011

In compliance with the Wyoming Environmental Quality act (W.S. 35-11-101 through 1104, specifically 301(a)(i) through 301 (a)(iv), Laws 1973, Chapter 250, Section 1) and Wyoming Water Quality Rules and Regulations, Chapter 16.

Applicant: Yellowstone National Park Norris Junction, Publicly Owned Treatment Works P.O. Box 169 Yellowstone National Park, WY 82190 (307) 344-2310 (office)

Yellowstone National Park, hereafter referred to as the permittee, is authorized to operate the waste water treatment facility located in Park County. The pennittee is allowed to operate the facility according to the procedures and conditions of application 13-144, and requirements and other conditions of this permit.

This pennit shall become effective on the date of issuance and is valid for ten (10) years.

Kevin Frederick, Administrator Water Quality Division Herschler Building, 122 West 25 th Street Cheyenne, WY 82002

Todd Parfitt, Director Department of Environmental Quality Herschler Building, 122 West 25th Street Cheyenne, WY 82002 JP/rmll3-1008

PERMIT 13-144 Revised July 31, 2013

Page 1 of 11

{Jt-f,r4, del ~ I

Date

Date

Page 170: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Table of Contents

A. Discharge Zone ................................................................................................................ 3

B. Well Locations and Areas of Review .............................................................................. 3

C. Groundwater Classification ............................................................................................. 3

D. Authorized Operations ..................................................................................................... 3

E. Hazardous Waste ............................................................................................................ .4

F. Proper Operation and Maintenance ................................................................................ .4

G. Entry and Inspection ........................................................................................................ 4

H. Environmental Monitoring Program for Groundwaters of the State .............................. .4

1. Requirements for Monitoring Groundwaters of the State ............................................... 7

J. Test Procedures ................................................................................................................ 8

K. Records and Reports ........................................................................................................ 8

L. Permit Actions ................................................................................................................. 8

M. Abandonment. .................................................................................................................. 9

N. Duties of the Permittee .................................................................................................... 9

O. Special Permit Conditions ............................................................................................... 9

P. Signatories Requirement ................................................................................................ 1 0

Q. Noncompliance .............................................................................................................. 10

R. Permit Transfer .............................................................................................................. 11

S. Propeliy Rights .............................................................................................................. 11

T. Permit Transfer .............................................................................................................. 11

PERMIT 13-144 Revised July 31, 2013

Page 2 of 11

(

(

Page 171: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

A. Discharge Zone The permittee is authorized to inject an average of 45,000 gallons per day (gpd) and a maximum of 75,000 gpd of tertiary treated domestic wastewater from the Norris Junction POTW into an existing leachfield. The wastewater is injected into the unconfined Gibbon River Alluvium. The shallowest groundwater is approximately ten (10) feet below ground surface based on the measured depth to groundwater from the four (4) monitoring wells surrounding the leachfield in the summer of2012.

B. Well Locations and Areas of Review The injection well (sanitary leachfield) authorized by this permit is located in the SESW Quarter­Quarter of Section 23, T55N, Range 115 West of the 6th principal meridian.

The Area of Review is defined as a circular area of 730 acres with the point of injection located near its center.

The Area of Review is based upon the following assumptions:

C. Groundwater Classification The groundwater in the unconfined alluvial aquifer beneath the permittee's property is classified as Class I according to Wyoming Water Quality Rules and Regulations, Chapter 8. This classification is made because the groundwater in this formation is assumed to be Class I by quality. Ground water is a major contributor to surface flows in nearby Gibbon River, which is currently being utilized as the water source for this facility. There are no wells permitted by the Wyoming State Engineer's Office located within one mile of this facility.

Groundwater of Class I shall not be degraded to malce it unusable as a source of water for this purpose. An aquifer that contains less than 10,000 mgIL total dissolved solids (and is not exempted) can be considered an tmderground source of drinking water.

D. Authorized Operations The injectate (effluent) quality and volume shall not exceed limits listed in Table 2 of this permit. The ground water in the monitor wells shall not exceed any limit listed in Table 2 of this permit, nor any standard for Class I grOlmd water listed in Chapter 8, Water Quality Rules and Regulations, whichever is more stringent.

The operator is authorized to inj ect at a pressure of no more than atmospheric pressure as measured at the wellhead.

PERMIT 13-144 Revised July 31, 2013

Page 3 of 11

Page 172: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

In the case where the treatment system needs to be enlarged to accept a greater sewage flow or if the permittee plans on accepting additional sewage flows that would increase their discharge volume (-beyond the maximum permitted rate, the permittee must submit a revised application and receive a new permit prior to modification of the treatment system or prior to discharging beyond the maximum permitted rate.

E. Hazardous Waste This permit does not allow for the injection of any hazardous waste as defined in 40 CFR 261.3 and in Wyoming Solid Waste Management Rules and Regulations, Chapter 2. Injection of any substance defined as a hazardous waste, whether hazardous by listing or by characteristic is a violation of this permit.

F. Proper Operation and Maintenance The permittee shall take all reasonable steps to minimize or correct any adverse impact on the environment resulting from noncompliance with this permit. The permittee shall operate and maintain all facilities and systems of treatment and control which are installed or used by the permittee to achieve compliance with the conditions of the permit. Proper operation and maintenance includes: effective performance, adequate funding, operator staffing and training, and laboratory and process controls, including appropriate quality assurance procedures. This provision requires the operation of back-up or auxiliary facilities or similar systems only when necessary to achieve compliance with the conditions of this permit. The injection wells covered by this permit shall meet all construction requirements outlined in Wyoming Water Quality Rules and Regulations, Chapters 11, 16 and 25.

The permittee is required to operate in accordance with statements, representations and procedures presented in the complete permit application and supporting documents as accepted and approved by the Administrator. Any modifications which will result in a violation of permit conditions shall be reported by submission of a new or amended permit application and shall not be implemented until a new or modified permit has been issued. Injection into any new well may not begin until construction is complete and the permit is approved.

G. Entry and Inspection The permittee shall allow the Administrator (upon presentation of credentials and during normal working hours) to enter the premises where a regulated facility is located, or where records are kept under the conditions of this permit and inspect and photograph the discharge and related facilities, review and copy reports and records required by this permit, collect fluid samples for analysis, measure and record water levels, and perform any other function authorized by law or regulation.

H. Environmental Monitoring Program for Groundwaters of the State General Requirements:

1. Samples and measurements taken for the purpose of monitoring shall be representative of the monitored activity. A groundwater sample is considered representative of the aquifer being monitored when the well has been purged to remove stagnant water prior to collection of a sample for laboratory analysis. Purging can be considered complete when a sufficient volume

(

of water has been removed from the well and stabilization of select groundwater parameters <: I

PERMIT 13-144 Revised July 31, 2013

Page 4 of 11

Page 173: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

has been achieved. It is important to record the circumstances surrounding each sample collection event at your facility. These records can help resolve analytical discrepancies. Either of the purging methods below shall be used prior to sample collection:

a. Purge by Volume Removal of a minimum of three (3) casing volumes of water from the well should be completed prior to collecting a groundwater sample. Minimum purge volume can be calculated by the following equation:

Minimum Purge Volume = 3 * «Total Well Depth in feet - Depth to Water in feet) * Well Capacity) Where Well Capacity (gallons per foot) is based on well diameter:

2 inch well = 0.163 6 inch well = 1.47 4 inch well = 0.653 8 inch well = 2.61

b. Stabilization of Parameters Field parameters measured during purging should include at a minimum temperature, pH, and specific conductance. Field parameters should be measured after removal of every half casing volume of water.

Half Casing Volume = 0.5 * «Total Well Depth in feet - Depth to Water in feet) * Well Capacity)

Where Well Capacity (gallons per foot) is based on well diameter: 2 inch well = 0.163 6 inch well = 1.47 4 inch well = 0.653 8 inch well = 2.61

A minimum of six (6) parameter measurements should be collected. If field parameters have not stabilized between the last three (3) readings, purging and parameter measurement should continue until stabilization has been achieved. Stabilization can be demonstrated by a variance of no more than +/- 10% for temperature and specific conductance, and +/- 0.2 standard units for pH.

2. The permittee shall retain records of all monitoring information including all calibration and maintenance records, copies of the reports required by this permit, and records of all data used to complete the application for this permit, for a period of at least three (3) years from the date of the sample measurement, report, or application. This period may be extended by request of the Administrator at any time.

3. The pe=ittee shall use electronic data deliverable (EDD) reporting when required by the Administrator.

4. Records of monitoring information shall include: a. The date, exact place, and time of sampling or measurements; b. The name(s) of the individual(s) who performed the sampling or measurements; c. The date(s) analyses were performed; d. The time(s) analyses were initiated; e. The name(s) of the individual(s) who performed the analyses;

PERMIT 13-144 Revised July 31, 2013

Page 5 of 11

Page 174: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

f. References and written procedures for the analytical techniques or methods used; g. The results of such analyses, including the bench sheets, instrument readouts, (

computer disks or tapes, etc., used to determine these results.

5. Monitoring must be conducted according to test procedures approved under 40 CFR Part 136, unless other test procedures have been specified in this permit.

6. The permittee shall retain all records concerning the nature and composition of injected fluids (final effluent), even if the records/data are in excess of the minimum sampling and analysis requirements of this permit. Records shall be kept until five (5) years after completion of any specified plugging and abandonment procedures. The administrator may require the owner/operator to deliver the records to the administrator at the conclusion of the retention period.

7. The permittee shall report any noncompliance which may endanger health or the environment within twenty-four (24) hours from the time the operator becomes aware of the circumstances, to include:

a. Any monitoring or other information which indicates that any conk'lminant may cause an endangerment to a usable groundwater of the state;

b. Any noncompliance with a permit condition or malfunction of the discharge (injection) system which may cause fluid migration into or between usable ground waters of the state;

A written submission shall be provided within five (5) days of the time the operator becomes ( aware ofthe circumstances. This written submission shall contain:

a. a description of the noncompliance and its cause b. the period of noncompliance, including exact dates and times, and c. if the noncompliance has not been cOiTected, the anticipated time it is expected to

continue; and steps taken or planned to reduce, eliminate, and prevent reoccurrence of the noncompliance.

8. The permittee shall report all instances of noncompliance not reported otherwise, at the time monitoring reports are submitted.

9. The monitoring reports shall be submitted on forms provided by the Department. Reports of compliance or noncompliance with, or any progress reports on, interim and final requirements contained in any compliance schedule of this permit shall be submitted no later than forty-five (45) days following each schedule date.

PERMIT 13-144 Revised July 31, 2013

Page 6 of 11

(

Page 175: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

I. Requirements for Monitoring Groundwaters of the State The injected fluid and groundwater in the receiving formation shall be sampled and the following parameters analyzed according to the schedule identified in Table 3, below.

Table 2 Groundwater Monitoring Schedule)*

/l;A~~Ll~b iikAM~;Jiti ' . i'SCHE))uLE 'ANiALYZEP': ,:,~,' \">,, - -'-;,_ ',.: .' .- "'i~:~)< '-' -:;;,;:>j,;';!.::" Ii E~;'Mdi()D~~~'~fJ:.!"i' .. ~!~=~Htl;!lii~~ . WELL: ..•. /.

NAMEO.Ri····. . NUMBlfRi ,,'

#Ammonia as N I 350.1 I HACHTNT830 I N/A (see below) 28 days/4° C

Monthly Sampling #Nitrate as N 300.0; 353.1; 353.2; or 353.3 HACH TNT8351l0206 N/A (see below) 28 days / 4° C Treatment

Plant Effluent (during operational *Total Coliform Membrane Filter/I 103.1 EPA 1604 N/A (see below) 24 hours /4° C

season); (In j ectate) Quarterly Reporting pH pH Meter; ISO. I or 150.2 >6.5 and <8.5

measure during sample collection .

.

Total Volume Injected Flowmeter 75,000 gpd N/A

#Ammonia as N 350.3 HACHTNT830 0.50 mgIL 28 days/4° C

Monitoring Wells; One Annual sample #Nitrate as N 300.0; 353.1; 353.2; or 353.3 HACH TNT8351l0206 10 mgIL 28 days/4° C

MW-I, (spring would be MW-2, best due to higher MW-3, groundwater levels). *Total Coliform Membrane Filterlll03.1 EPA 1604 Absent 24 hours/ MW-4

pH pH MeIer; 150.1 or 150.2 >6.5 and <8.5 measure during

sample collection.

NOTES: * A routine sample that is positive for coliforms, triggers repeat samples - a violation only occurs if any repeat sample is positive for total coliform. # These constituents must be sampled concurrently.

All chemical concentrations in this permit are expressed in mg/I unless otherwise noted. The above Upper Control Limits (VCL) are not to be exceeded in any sample. Exceedance of any UCL is a violation of this permit and shall require corrective action. Wyoming Water Quality Rules and Regulations Chapter 16 require the effluent to be sampled after treatment but prior to discharge. The points of compliance for this permit are the downgradient monitoring wells; therefore there are no UCL's for the injectate.

PERMIT 13 -144 Revised July 31, 2013

Page 7 of 11

Page 176: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

J. Test Procedures All samples and measurements taken for the purpose of monitoring shall be representative of the monitored activity. All required analyses shall be conducted in compliance with Wyoming Water Quality Rules and Regulations, Chapter 8, Section 7.

Ammonia as N and Nitrate as N shall always be sampled concurrently, reSUlting in paired values for every sampling event.

K. Records and Reports The permittee shall furnish to the Administrator within a specified time any information which the Administrator may request relating to the operation of the facility, including copies of records required to be kept by this permit. The permittee shall retain copies of all records and reports required by this permit for a period of three (3) years following permanent well abandonment. After that time, those records shall be delivered to the Administrator for disposal or archive at his discretion. Confirmed noncompliance resulting in the migration of injected fluid into any zone outside the permitted receiver shall be reported to the Administrator within twenty-four (24) hours, and a written submission (via certified mail) shall be provided within five (5) days of the time the permittee becomes aware of the excursion. The written submission shall contain:

• a description ofthe noncompliance; • the period of noncompliance, including exact dates and times, and if the noncompliance has

not been controlled, the anticipated time it is expected to continue; and

(

• a list of the steps taken or plarmed to reduce, eliminate, and prevent the recurrence of the noncompliance. (

Confirmed noncompliance not already reported under this section shall be reported at the time monitoring reports are submitted. The reports shall contain the same information as required by the paragraph above. The permittee shall notify the Administrator thirty (30) days in advance of any planned alteration, conversion, or abandonment of the well covered by this permit.

L. Permit Actions This permit is authorized for a period often (10) years. If the permittee wishes to continue injection after the expiration date of this permit he shall apply to the Administrator and obtain a new permit. The application should be submitted at least six (6) months before the expiration date of this permit. Under this permit, the Department may consider injection after the expiration date a violation of the permit.

It shall not be a defense for the permittee in an enforcement action that it would be necessary to halt or reduce the permitted activity in order to maintain compliance with the conditions of the permit. The filing of a request by the permittee, or at the instigation of the Administrator, for permit modification, revocation, termination, or notification of plarmed changes or anticipated noncompliance shall not stay any condition of this permit.

After notice and opportLmity for a hearing, a permit may be modified, suspended or revoked in whole or part during its term for cause which includes, but is not limited to any of the following:

PERMIT 13-144 Revised July 31, 2013

Page 8 of 11

(

Page 177: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

1. Violation of this permit; or 2. Obtaining a permit by misrepresentation of facts in the application.

This permit will be reviewed at least once every five (5) years, and may be reviewed more frequently. A permit may be modified at any time as may be required, including for conformity with changes in regulations or standards which occur after the permit was issued. A permit may be modified in whole or part in order to apply more or less stringent standards; or prohibitions for toxic or other substances present in the permittees discharge as may be ordered by the Environmental Quality Council.

M. Abandonment General Requirements:

1. The permittee shall notifY the administrator at least thirty (30) days prior to abandonment of the facility.

2. An abandonment report, detailing the compliance with abandonment procedures outlined in the original application for coverage under this permit, or describing any deviations from the original plan, shall be submitted as soon as practicable after abandonment. The abandonment shall include reclamation of the well site.

3. Injection wells covered by this permit shall be abandoned in accordance with Wyoming Water Quality Rules and Regulations, Chapter 16, Section 12.

N. Duties of the Permittee The permittee shall give advance notice to the Administrator as soon as possible of any planned physical alteration or additions, other than authorized operation and maintenance, to the permitted facility and receive authorization prior to implementing the proposed alternation or addition. The permittee shall furnish the Administrator within a reasonable time any information which the Administrator may request to determine whether cause exists for modifying, revoking, or reissuing, or terminating this permit, or to determine compliance with this permit; and to furnish to the Administrator upon request, copies of records required to be kept by this permit. Any modification which may result in a violation of a permit condition shall be reported to the Administrator, and any modification that will result in a violation of any permit conditions shall be reported to the Administrator through the submission of a new or amended permit application. The permittee shall report all instances where he becomes aware that he failed to submit any relevant facts in the permit application, or where he submitted incorrect information in a permit application or in any report to the Administrator, and shall promptly submit such facts or information.

If any cultural materials are discovered during construction, work in the area should halt immediately. The Administrator and the Wyoming State Historic Preservation Office shall be contacted (777-7697) and the materials shall be evaluated by an archaeologist or historian meeting the Secretary of the Interior's Professional Qualification Standards (48 FR 22716, Sept. 1983).

O. Special Permit Conditions In addition to the conditions required of all permits, the Administrator may establish specific conditions to clarifY the permit and prevent contamination of underground sources of drinking water. The following specific conditions are established for this permit.

PERMIT 13-144 Revised July 31, 2013

Page 9 of11

Page 178: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

P. Signatories Requirement All reports filed in conjunction with this permit shall contain the following certification:

"1 certify, under penalty of law that this document and all attachments were prepared tmder my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is to the best of my knowledge and belief, true, accurate, and complete. 1 am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations."

All reports required by this permit and other requested information shall be signed as follows:

For a corporation - by a principal executive officer of at least the level of vice-president;

For a partnership or sole proprietorship - by a general partner or the proprietor, respectively;

For a municipality, state, federal, or other public agency - by either a principal executive officer or ranking elected official; or

By a duly authorized representative for any of the above. A person is a duly authorized representative only if:

1. The authorization is made in writing by one (1) of the prescribed principals;

2. The authorization specifies either an individual or position having responsibility for the overall operation ofthe regulated facility or activity; and

3. The written authorization is submitted to the Administrator.

If an authorization is no longer accurate because a different individual or position has responsibility for the overall operation of the facility, a new authorization must be submitted to the Administrator prior to or together with any reports or information, to be signed by the new authorized representative.

Q. Noncompliance The permittee shall comply with all conditions ofthe permit. Any permit noncompliance constitutes a violation of Wyoming Water Quality Rules and Regulations, Chapter 16 and is grounds for enforcement action, permit termination, revocation, or modification. Conformed noncompliance resulting in an excursion shall be reported to the Administrator orally within twenty-four (24) hours, and a written submission shall be provided within five (5) days of the time the permittee becomes aware of the excursion. The written report shall contain the sections specified in Section K of this permit. Any permit noncompliance constitutes a violation of this permit.

PERMIT 13-144 Revised July 31, 2013

Page 10 of 11

(

(

(

------- ----- ---

Page 179: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

The filing of any request by the permittee for a permit modification, revocation and reissuance, or termination, or a notification of planned changes or anticipated noncompliance, does not stay any permit condition.

R. Permit Transfer Any transfer of this permit shall be accomplished by the submission of the proper forms for permit transfer to the Administrator. Transfer of this permit must first be approved by the Administrator and the Director. No transfer shall be approved unless the proposed permittee agrees to bring any and all noncompliance issues into compliance with this permit. The permittee is alone responsible for the operation of the facility covered by this permit. Sale of the facility and subsequent operation of this facility by another is a violation of this permit unless a transfer of this permit has first been accomplished.

S. Property Rights This permit does not convey any property rights of any sort or any exclusive privilege. This permit does not authorize injury to private property or any invasion of personal rights, nor any infringement offederal, state, or local laws or regulations.

T. Permit Transfer Nothing in this permit shall be construed to preclude the institution of any legal action or to relieve the permittee from any responsibilities, liabilities, or penalties established pursuant to any applicable state law or regulation.

PERMIT 13-144 Revised July 31, 2013

-End of Permit-

Page 11 of 11

Page 180: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(

(

Page 181: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality

Matthew H. Mead, GovernOl"

October 14,2013

National Park Service Attn: Ms. Nancy Ward P.O. Box 168 Yellowstone NP, WY 82190

To protect, conserve and enhance the quality of Wyoming's

environment for the benefit of current and future generations.

RE: Norris Junction Publicly Owned Treatment Works (POTW), Class V Pennit Renewal Final Permit 13-144, Facili1y Number: WYS-029-118 Park Coun1y, Wyoming

Dem' Ms. Ward:

Todd Parfitt, Director

Attached please find one copy of the Class V septic system permit for the facili1y referenced above. This permit requires quarterly water quali1y analysis of your monitoring wells, weekly water quali1y analysis of your effluent, and subsequent reporting. The corresponding report fonns can be filled out using our on-line webform (Monitor Reports Link), or one may submit them using Electronic Data Deliverable (EDD) at the following site: http://gem.wqd.apps.deq.wyoming.gov. For your convenience, the Wyoming Department of Environmental Quali1y (WDEQ) has printed the inspection forms and enclosed them in this mailing, you may use the paper fonns to report your inspectiou and monitoring activities to WDEQ.

The underground injection control program was promulgated to prevent serious problems caused by direct dischm'ges to the groundwater. Those problems included groundwater pollution leading to contamination in domestic water wells and serious health affects caused by exposures to toxic substances and water borne pathogens. Your cooperation with our program is sincerely appreciated.

If you have any questions please do not hesitate to contact me at the below referenced phone number or email.

Sincerely,

jLm~ John A. Passehl, P.G. UIC Geology Supervisor Wyoming Department of Environmental Quality Water Quality Division (307) 777-5623 [email protected]

JP/rml13-1008

Enclosures: Permit Monitoring Report Forms

Herschler Building' 122 West 25th Street· Cheyenne, WY 82002 . http://deq.state.wy.lIs ADMIN/OUTREACH ABANDONED MINES

(307) 777-7758 (307) 777-6145 PAX 777-7682 FAX 777-6462

AlRQUALITY (307)777-7391 FAX 777-5616

INDUSTRIAL SITING (307) 777-7369 FAX 777-5973

LAND QUALITY SOLTD& IIAZ. WASTE (307) 777-7756 (307) 777-7752 FAX 777-5864 FAX 777-5973

WATER QUALTTY (307) 777-7781 FAX 777-5973

Page 182: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(

(

Page 183: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

WYOMING DEPARTMENT OF ENVIRONMENTAL QUALITY WATER QUALITY DIVISION PERMIT TO CONSTRUCT

PERMIT NO. 13-145 EXisting Permit 93-096

Naughton Power Plant - North Ash Pond Unit 3 -Interim Cover

This permit hereby authorizes the applicant:

Shawn Smith PacifiCorp

P.O. Box 191 Kemmerer. WY 83101

to construct an interim fugitive dust control cover system for an existing permitted ash disposal pond. the cover system will consist of bottom ash covered with vegetated native soil placed over fugitive dust areas according to the procedures and conditions of the application number 13-145. The facility is located about 3.5 miles southwest of the Town of Kemmerer at Long: Lat: 41.761' and Long:-11 0.598' in the county of Lincoln, in the State of Wyoming. All construction, installation, or modification allowed by this permit shall be completed by May 15, 2016.

The issuance of this permit confirms that the Wyoming Department of Environmental Quality (DEQ) has evaluated the application submitted by the permittee and determined that it meets minimum applicable construction and design standards. The compliance with construction standards and the operation and maintenance of the facility to meet the engineer's design are the responsibility of the permittee, owner, and operator.

Granting this permit does not imply that DEQ guarantees or ensures that the permitted facility, when constructed, will meet applicable discharge permit conditions or other effluent or operational requirements. Compliance with discharge standards remains the responsibility of the permittee,

Nothing in this permit constitutes an endorsement by DEQ of the construction or the design of the facility described herein. This permit verifies only that the submitted application meets the design and construction standards imposed by Wyoming statutes, rules and regulations. The DEQ assumes no liability for, and does not in any way guarantee or warrant the performance or operation of the permitted facility. The permittee, owner and operator are solely responsible for any liability arising from the construction or operation of the permitted facility. By issuing this permit, the State of Wyoming does not waive its sovereign immunity.

The permittee shall allow authorized representatives from DEQ to enter and inspect any property, premise or place on or at which the facility is located or is being constructed or installed for the purpose of investigating actual or potential sources of water pollution, and for determining compliance or non­compliance with any rules, regulations, standards, permits or orders.

Nothing in this permit shall be construed to preciude the institution of any legal action or other proceeding to enforce any applicable provision of law or rules and regulations. It is the duty of the permittee, owner and operator to comply with all applicable federal, state and local laws or regulations in the exercise of its activities authorized by this permit.

Page 1 of 3

Page 184: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

The issuance of this permit does not convey any property rights in either real or personal property or any invasion of personal rights, nor any Infringement of federal, state or local laws or regulations.

The permittee shall construct and operate the permitted facility in accordance with the statements, ( representations, procedures, terms and conditions of the permit application, supporting documents and permit. This permit does not relieve the permittee from any duty to obtain any other permit or authorization that may be required by any provision offederal, state or local laws.

In carrying out its activities authorized by this permit, the permittee, owner and operator shall comply with all of the following permit conditions:

1 of 3 The applicant will provide immediate oral or written notice to the Wyoming Department of Environmental Quality, Water Quality Division (WQD), Southwest District Engineer,51 0 Meadow View Drive, Lander, WY 82520, 307-332-3144,FAX 307-332-7726, in accordance with the provisions of Section 11, Chapter 3, Wyoming Water Quality Rules and Regulations of any changes or modifications which are not consistent with the terms and conditions of this permit.

2 of 3 Within sixty days of completion of construction of the authorized facility, the applicant will submit to the Southwest District a certification of completion signed by the Engineer of Record or the owner. A form titled "Certificate of Completion" has been provided and must be completely filled out.

3 of 3 The review and approval of this permit is based upon the items identified in the attached "Statement of Basis".

AUTHORIZED BY:

JLLd Kevin Frederick Administrator Water Quality Division

5-d, (J - \:::, Date of Issuance

MDB/rm/13-0459

Page 2 of 3

Todd Parfitt Director Department of Environmental Quality

(

(,

Page 185: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

STATEMENT OF BASIS

I 1. Permit Number: 13-145

2. Application reviewed for compliance with the following regulations:

Yes. Chapters 3. and 11 of the Wyoming Water Quality Rules and Regulations.

3. If a Section 17 of Chapter 3 review is required indicate the basis for determining groundwater will be protected.

The requirements of Section 17 of Chapter 3 are being met by PacifiCorp's ongoing groundwater monitoring program which is being conducted with oversiqht by the Water Quality Division's Groundwater Pollution Control Program.

4. Documentation of Statement of Basis: The archive file for this permit includes adequate documentation of all sections of this Statement of Basis.

CERTIFICATION

The issuance of this permit is based upon a review of the application package submitted in accordance with the requirements of Chapter 3, Section 6, Wyoming Water Quality Rules and Regulations. This review was performed by Mark D. Baron, P .E., [email protected], Southwest District Engineer and completed on May 15, 2013. Permit issuance is recommended based upon statements, representations, and procedures presented in the permit application and supporting documents, permit conditions, and the items identified in this "Statement of Basis."

cc: David J Erickson, P.G., Water & Environmental Technologies, 480 East Park St., Butte, MT Joshua T. Vincent, P.E., Water & Environmental Technologies, 480 East Park St., Butte, MT

Page 3 of 3

Page 186: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(

( /

Page 187: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Ouality

To protect, conserve and enhance the quality of Wyoming's environment for the benefit of current and future generations.

Matt Mead, Governor Todd Parfitt, Director

NOTIFICATION OF COVERAGE April 23, 2013

Chris Riker, Project Manager' Fremont County School District #2 314 Helmer Street Dubois, WY 82513

RE: FCSD#2 Dubois K·12 water and sewer improvements DEQ Permit #13·146 Located In Fremont County, SW Y.i, S6, T41N, R106W; Lat. 43.5408, Long. ·109.6286

Dear Mr. Riker,

This project consists of rerouting a 6 inch PVC water line to accommodate new building construction, rerouting approximately 187 linear feet of 8 Inch PVC sanitary sewer, extending approximately 30 linear feet of 8 inch sanitary sewer main, and constructing approximately 391 linear feet of new 6 Inch sewer service including 4 manholes and 4 cleanouts to the building addition.

The above application for coverage under General Permit has been reviewed In accordance with Chapter 3, Section 7; Chapter 11 and Chapler 12 of the Wyoming Water Quality Rules and Regulations and is hereby approved.

You are authorized to construct, the facility in accordance with the general permit and the materials submitted in your application package, and the General Permit to Construct, Install, Modify or Operate Extensions to or Modification to Existing Public Water Supply Dlstrlbu!lon Systems and the General Permit to Construct, Install, Modify or Operate Extensions to or Modification of Existing Sewage Collection Systems. Your attention Is directed to the mandatory reporting requirements outlined in Part V, Section 0 01 the general permit. Construction shall be completed by October 31, 2015

Your attention is directed to the attached Certificate of Completion form, which is to be submitted within 60 days of the completion of the aforementioned project.

These General Permit requirements can be downloaded from the Wyoming Department of Environmental Quality webpage. The General Permits can be found under the Water Quality DiviSion Water and Wastewater Program, Engineering and Technical Services at:

httR:lldeq.state.wy.uslwqdlwwwIPermitting/Pages/general permits.asp

If you have any questions, please contact Hannes Stueckler at 307-335-6964 or James Brough at 307-335·6961.

S~9F~ Hannes E. Stueckler, P.E. Assistant Northwest District Engineer Water Quality Division

xc: PDF to Cheyenne Terry Zenk, Apex Surveying, Inc., P.O. Box '18-751, Cliverlon, WY 82501

Lander Field Office • 510 Meadowview Drive • Lander, WY 82520 • http://deq.state.wy.u5 ABANDONED MINES

(307) 332-5085 FAX 332-7726

AIR QUALITY (307) 332-6755 FAX 332-7726

lAND QUALlTY (307) 332-3{147 FAX 332-7726

SOUP & HAZARDOUS WASTa: (307) 332-6924 FAX 332-7726

WATER QUAl,ITY (307) 332-3144 FAX 332-7726 •

Page 188: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(

(

(

Page 189: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Mnlthew H. Mead. Governor

June 20, 2013

Keith Tyler

Department of Environmental Quality To protect conserve, end enhance the quality of IWOmlng's

environment for the ben9fft of current and future generations.

152 N. Durbin SI., Suite 100 . Casper, WY 82601 . (307) 473-3450

NOTIFICATION OF COVERAGE

River Heights Development, LLC 421 South Center Street Casper, WY 82601 .

RE: River Heights Subdivision Application No. 13-148, Natrona County, WY

Dear Mr. Tyler:

Todd Parflll, Director

The above application for coverage under General Permits to Construct, Install, Modify or Operate Extensions to or Modifications of Existing Water Supply Distribution Systems and Existing Sewage Collection Systems, consisting of the installation of approximately 4,680 lineal feet of 8 inch PVC water line, 1,660 lineal feet of 12" PVC water line, and associated services, fire hydrants, and· valves,. and 4,845 lineal fcct of 8" PVC sanitary sewer line, associated sewer service lines, and sanitary sewer manholes, to serve" new 64 lot residential subdivision, located in the W Yz, SW lI.., Section 11, Township 33 North, Range 80 West, Natrona County, in accordance with Chapter 3, Section 9 of the Wyoming Water Quality Rules and Regulations has been reviewed and is hereby approved. YOll

are authorized to construct, install, or modify the facility in accordance with Chapter 11 and 12 of the Water Quality Division RlIles and Regulations, the General Permits, and the materials submitted in your application package. Your attention is directed to the mandatory reporting requirements outlined in Psrt V, Section 0 of the general permit. All construction, installation, or modification allowed by this Notification of Coverage shall be completed by December 31, 2015.

This Notification of Coverage is covered under the General Permits on the Wyoming Department of Environmental Quality webpage:

http://deq.state.wy.us/wqd/www/Permitting/Pagos/general permits. asp

If you have any questions, please contact me at 307-473-3478.

Sincerely,

d/~i.~" Karen L. Farley, P.E. NE District Engineer WDIlQ/WQD

cc: IPS, Cheyenne WDEQ Casper Vile Brad Holwegner, P.E., WLC, 200 Pronghorn, Casper, WY 82601 Dave Hill, City of Caspel', 200 North David, Casper, WY 82601 Mike Coleman, Town of Mills, P.O. Box 789, Mills, WY 82644

Ch:;renne 122 West 25' S!rcet 82002

(307) 777-7937

Lander 5 JO Meadowview Drivo 82520

(307) 332"3144

Sheridan 2100 W. 5'h S!rcet 82801

(307) 673"9337

Page 190: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

( "

(i

Page 191: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

Department of Environmental Quality

To protect, conserve, and enhance the quality of Wyoming's

environment for the benefit of current and future generations.

Matthew H. Mead, Governor 152 N. Durbin St., Suite 100 . Casper, WY 82601 . (307) 473-3450

June 3, 2013

Brad Holwegner, P.E. WLC Engineering 200 Pronghorn Street Casper, WY 82601

RE: River Heights Subdivision Location: SW v., Section 11, Township 33N, Range 80W WDEQ Application #13-148

Dear Mr. Holwegner:

Todd Parfitt, Director

We have completed our review of the permit application submitted on April 18, 2013. Attached you will find a summary of the review comments. Please provide the information requested as soon as possible. Please feel free to contact me at (307) 473-3478 should you have any questions related to these comments or the application and review process.

Sincerely,

~~J~ Karen L. Farley, P.E. Northeast District Engineer WDEQ/WQD

Attachments: WDEQ Comments

cc: IPS WDEQFile

Chel.'enne 122 West 25 t Street 82002

(307) 777-7937

Lander 510 Meadowview Drive 82520

(307) 332-3144

Sheridan 2100 W. 5th Street 82801

(307) 673-9337

Page 192: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

( (

('

(

(!

Page 193: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

REVIEW OF PLANS & SPECIFICATIONS WYOMING DEPARTMENT OF ENVIRONMENTAL QUALITY

WATER QUALITY DIVISION 152 North Durbin Street, Suite 100

Casper, Wyoming 82601 Phone (307) 473-3465

PROJECT: River Heights Subdivision

LOCATION: Natrona County, Wyoming

ENGINEER: WLC Engineering

APPLICANT: River Heights Development, LLC.

WATER QUALITY DIVISION APPLICATION NUMBER: 13-148

DATE ON PROPOSALIPLANSIREPORT: April 18, 2013

DATE RECEIVED BY DEQ: April 18,2013

DATE OF THIS REVIEW: June 3, 2013

WDEQ REVIEWERS: Jason Vreeland, P.E., Karen 1. Farley, P.E.

ACTION: NOT AUTHORIZED FOR CONSTRUCTION. In accordance with Chapter 3, Section 14 (a), Wyoming Water Quality Rules and Regulations (WWQRR), the application is denied because it is incomplete and/or contains errors. Please address the comments outlined below and submit the requested information/clarifications in order that the application process may be completed in accordance with Chapter 3, Section 9 of the WWQRR. Ifthe applicant fails to provide the requested information within six months, the incomplete application shall be returned. This review may not include all deficiencies and shall not be construed as a complete comprehensive list.

WDEQ COMMENTS

1) Chapter 12, Section 6(b )(iv) - It does not appear that the overall capacity of the Town of Mills' water system was evaluated. Please discuss the available storage and production of the system and how the new development mayor may not affect this. This type of analysis is critical when additional development such as this occurs.

2) Chapter 12, Section 14(b )(i) - Please provide the pipe analysis and pipe and friction losses that should have been done as part of the overall modeling of the system. Based upon what was provided in the Poison Spider Replacement project, it appears that the hydraulic grade used was 5428.60, but there was no other factors tal(en into account when the resultant pressures were calculated. This information, as well as tank levels and other pertinent information on well

2

Page 194: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

( (

f'

(

(.

Page 195: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

i

-~

production and tank storage capabilities should have been included in the design report. In addition, please provide justification for the 12" line used in Poison Spider. Please address.

3) Chapter 12, Section 6 - The design report stated that water for the development will be provided by a connection to the Town of Mills and a connection to Regional- please clarify.

4) Chapter 12, Section 14(e) - WWQRR require air relief valves at all high points. Sheet 17 appears to show a high point near 3+50 without any means of air relief.

5) Chapter 12, Section 7( c) - Sheet 19 appears to show a water utility crossing at approximately station 13+60 on the plan view, but this crossing isn't shown on the profile. Please address.

6) Chapter 12, Section 14(g) - The storm sewer crossing shown near station 14+30 on Sheet 31 appears to be less than 18 inches. Please address.

7) Chapter 12, Section 7(c) - Manhole 18 on Sheet 43 appears to show the invert elevation in and out switched. Please address.

8) Chapter 12, Section 14(e) - Sheet 44 shows a water crossing near station 18+90 on the plan view but not on the profile. Please address.

9) Chapter 12, Section 14(d) - Please comment on the distance from the seasonally high groundwater level and to hydrant drains for all proposed hydrants on the project.

10) Please clarify the water lines along Poison Spider Road. Sheet 23 of the plan set indicates that the 14" line on the south side of Poison Spider is operated by CWRWS. Sheet 4 of the Poison Spider Water Replacement Project appears to indicate that this line is operated by the Town of Mills. Please address.

11) Chapter 12, Section 7( c)(i) - Please identify the symbols used on Sheet 23 (in particular) - they appear to be meter pits, but the legend does not have information on this. Also, what are the two lines that are shown running southeast/northwcst? In addition, please show the new line from the Poison Spider project that was proposed to have been installed in the middle of the road.

12) Chapters 12, Section 14(g) - Please review and address all water services that are located within 10' of sanitary sewer manholes.

13) Chapter 12, Section (b )(vii) - Please address this dead-end section of line. 14) Chapter 12, Section (d) - FH-IO shown on Sheet 31 should be installed on the 8" line by a tee

and a separate hydrant lead and valve. The way it is shown, it is tied directly onto the 8" main. Please address.

3

Page 196: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(\ ( "

('

(

(

Page 197: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

WYOMING DEPARTMENT OF ENVIRONMENTAL QUALITY WATER QUALITY DIVISION

STATEWIDE PERMIT TO CONSTRUCT

CHANGE OF OWNERSHIP PERMIT NO. 13-149 SPECIAL CONDITIONS

REF/PERMIT NO.08-666

Barium Removal Treatment Process Using TBEC CLEANSWEEP for CBM Produced Water

This permit hereby authorizes the applicant:

Encore Energy Partners Operating, LLC 1414 Lincoln Street

Gillette, Wyoming 82716

to assume the permit for the Barium Removal Treatment process Using TBEC, INC. CLEANSWEEP- acid injection for CBM produced water, and operate it according to the procedures and conditions of this permit number 13-149. and as derived from the reference permit number 08-666. The facility is located Statewide in the State of Wyoming.

The issuance of this permit confirms that the Wyoming Department of Environmental Quality (DEQ) has evaluated the application submitted by the permittee and determined that it meets minimum applicable construction and design standards. The compliance with construction standards and the operation and maintenance of the facility to meet the engineer's design are the responsibility of the permittee, owner, and operator.

Granting this permit does not imply that DEQ guarantees or ensures that the permitted facility, when constructed, will meet applicable discharge permit conditions or other effluent or operational requirements. Compliance with discharge standards remains the responsibility of the permittee.

Nothing In this permit constitutes an endorsement by DEQ of the construction or the design of the facility described herein. This permit verifies only that the submitted application meets the design and construction standards imposed by Wyoming statutes, rules and regulations. The DEQ assumes no liability for, and does not in any way guarantee or warrant the performance or operation of the permitted facility. The permittee, owner and operator are solely responsible for any liability arising from the construction or operation of the permitted facility. By issuing this permit, the State of Wyoming does not waive its sovereign immunity.

The permittee shall allow authorized representatives from DEQ to enter and inspect any property, premise or place on or at which the facility is located or is being constructed or installed for the purpose of investigating actual or potential sources of water pollution, and for determining compliance or non­compliance with any rules, regulations, standards, permits or orders.

Nothing in this permit shall be construed to preclude the institution of any legal action or other proceeding to enforce any applicable provision of law or rules and regulations. It is the duty of the permittee, owner and operator to comply with all applicable federal, state and local laws or regulations in the exercise of its activities authorized by this permit.

The issuance of this permit does not convey any property rights in either real or personal property or any invasion of personal rights, nor any infringement of federal, state or local laws or regulations.

The permittee shall operate the permitted facility in accordance with the statements, representations, procedures, terms and conditions of this permit, 13-149; referenced permits 06-178 and 08-666, and

Page 198: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

applicable supporting documents. This permit does not relieve the permittee from any duty to obtain any other permit or authorization that may be required by any provision of federal, state or local laws.

In carrying out its activities authorized by this permit, the permittee, owner and operator shall comply with all (" of the following permit conditions:

1 of 7 The applicant will provide immediate oral and/or written notice to DEQ CBM / Oil and Gas Group, 152 North Durbin Street, Suite 100, Casper, WY 82601, in accordance with the provisions of Section 9, Chapter III, Wyoming Water Quality Rules and Regulations of any changes or modifications which are not consistent with the terms and conditions of this permit.

2 of 7 Permit to Construct 08-666 was issued to allow use of the TBEC treatment process for the treatment of balium for CBM produced water from the Powder River Basin that requires such treatment and where the process will not increase other constituents above discharge limits.

3 of 7 The applicant shall provide the CBM / Oil and Gas Group, Water Quality Division with the information regarding disposal of any waste generated by the process at a DEQ approved facility.

4 of 7 During the first two months of operation of a new plant, the applicant will monitor operation of the facilities at least three times a week. After two moriths, if the operation of the facilities is within the stated operational parameters, monitoring will be conducted weekly.

5 of 7 An operation and monitoring report will be sUbmitted to the CBM / Oil and Gas Group, Water Quality Division monthly for the first two months of operation. If after two months, the facility is operating within stated parameters, operation and monitoring reports may be submitted quarterly. The operation and monitoring reports will include, at a minimum, influent water quality, amount of water treated at each location, other operational information, waste disposal, and effluent water quality. (

6 of 7 Following completion oitreatment, the treatment plant and all associated structures will.be reclaimed to the satisfaction of the land owner.

7 of 7 The review and approval of this permit is based upon the items identified in the attached "Statement of Basis".

AUTHORIZED BY:

J2'~ Kevin Frederick Administrator Water Quality Division

Date of Issuance

JDLlKJM/rm/13-0444

cc: WDEQ Casper Field Office (j

Page 199: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

STATEMENT OF BASIS

1. Permit Number: 13-149

2. Application reviewed for compliance with the following applicable regulations:

a. Chapter 11.

b. The STATEWIDE permit is based on completion of the Pilot Project permits# 06-178 and state wide permit #08-666

3. Does the permit comply with all applicable regulations identified above?

Yes

Application requires review to determine groundwater impacts in accordance with Section 17, Chapter 3.

a. Not required.

Documentation of Statement of Basis.

The archive file forthis permit will include adequate documentation of all sections of this Statement of Basis.

CERTIFICATION

The issuance ofthis permit is based upon a review of the application package submitted in accordance with the requirements of Section 6, Chapter III, Wyoming Water Quality Rules and Regulations. This review was performed by Kim Medina, Geologic Project Analyst, and completed on April 29, 2013. Permit issuance is recommended based upon statements, representations, and procedures presented in the permit application and supporting documents, permit conditions, and the items identified in this "Statement of Basis."

Page 200: Department of Environmental Qualitydeq.wyoming.gov/media/attachments/Water Quality...PDF to Cheyenne Mark Eatinger, P.E., Rio Verde Engineering, P.O. Box 642, Pinedale, WY 82941

(:

( }