dlc v4.1test report · best_dlc v4.1.doc . note: this report is not valid as a best test report...
TRANSCRIPT
DLC V4.1TEST REPORT Applicant’s name ............................: Shanghai Supertek Lighting Co., Ltd.
Address .............................................: No.455,laodongRoad,caowang industrial Zone,Jiading District,shanghai
Brand Name ....................................... : SUPERTEK
Report No.......................................... : BTR66.181.16.0028.14
Product Name .................................... : WALLPACK FIXTURE
Basic Model ....................................... : WP07B-100-4000K
Tested by (printed name and signature) ........... : Title .................................................... :
David Zhang Test Engineer
.....................................................
Approved by (printed name and signature) ........... : Title .................................................... :
Steven Huo Approved Signatory .....................................................
Date of issue .................................... : Apr 17, 2017
Testing Laboratory Name .............. : BEST Test Service Shenzhen Co., Ltd.
Address ............................................ : 1st Floor, 1st Building, Weitai Industrial Park, Yingrenshi, Shiyan, Baoan, Shenzhen, China TEL: + 86-755-28236006; FAX: + 86-755-23467087 Email: [email protected]
Accrediation ..................................... : DLC/Lighting Facts/UL/ETL/ELI/CEC/EPA/DOE NVLAP Testing Lab Code: 200770-0
Test specification
Standard ............................................ : DLC V4.1
Test procedure ................................. : DLC Test Procedure
Non-standard test method ............... : No
Test Report Form No. BEST_ DLC-V4.1
TRF originator. ................................... : BEST Test Service Shenzhen Co., Ltd. Mr Tseng
Master TRF ...................................... : BEST_DLC V4.1.doc Note:
This report is not valid as a BEST Test Report unless signed by an approved BEST Test Service Shenzhen Co., Ltd. This report shall not be reproduced except in full without the written approval of the testing laboratory. The test report only allows to be revised within the retention period unless further standard or the requirement was noticed. This report is for the exclusive use of BEST’s Client and is provided pursuant to the agreement between BEST and its Client. BEST’s responsibility and Liability are limited to the terms and conditions of the agreement. BEST assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the BEST name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by BEST. The observations and test results in this report are relevant only to the sample tested. This report by itself does not cover that the material, product, of service is or has ever been under a BEST certification program. National Voluntary Laboratory Accreditation Program (NVLAP) has accredited this laboratory under ISO17025: 2005 for specific laboratory activities as listed in the NVLAP directory of accredited laboratories. The results shown in this report were determined by this laboratory in accordance with its terms of accreditation. This report must not be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government.
Shanghai Supertek Lighting Co., Ltd. Basic Model: WP07B-100-4000K
Report No.BTR66.181.16.0028.14 Page 2 of 10 DLC V4.1 Test Report
Product description:
Sample received date ........................ : Apr 10, 2017
Sample Quantity ................................ : 1 pcs per model
Model Number ................................... : WP07B-100-4000K; WP07B-100-5000K
Rating(s) (V; Hz) ................................ : 120-277VAC 50/60HZ
Nominal Power ................................... : 100W
Nominal Power Factor ....................... : N/A
Nominal Lumen Output ...................... : 11800lm; 12000lm
Nominal CCT ..................................... : 4000K; 5000K
Nominal CRI(Ra) ............................... : ≥70
Nominal Life ....................................... : 50000H
Product Classification ...................... : Premium Standard
Category .................................................. :
Indoor Indoor Retrofit Kit
Outdoor Outdoor Retrofit Kit
Linear Replacement Lamp E39 Replacements for HID Lamps
Four Pin-Base Replacement Lamps for CFLs
General Applicant .............................. : Outdoor –high Output
Primary use ...................................... : Outdoor Full-Cutoff Wall-mounted Area Luminaires
Dimmable ......................................... : Yes, No
If Yes, Select Dimming Mechanism ... : Continuous dimming, Step dimming
If Yes, Mini Dimming Level ................ : 10%
Integral Controller .............................. : Yes, No
LED Lighting Source Manufacture ..... : Lumileds
LED Lighting Source Model ............... : LUXEON 3030 2D
LED Driver Brand ............................... : N/A
LED Driver Model Number .................. N/A
Maximum Recommended Temperature (ºC) During Normal Operation ........................................... :
N/A
Fixtures Band (Retrofit Kit/Lamp Only) .................... : N/A
Fixtures Model No. (Retrofit Kit/Lamp Only) .................... : N/A
Shanghai Supertek Lighting Co., Ltd. Basic Model: WP07B-100-4000K
Report No.BTR66.181.16.0028.14 Page 3 of 10 DLC V4.1 Test Report
Test Method Description ANSI C78.376-2001 Specifications for the Chromaticity of Fluorescent Lamps ANSI C78.377-2015 Specifications for the Chromaticity of Solid State Lighting Products ANSI/NEMA/ANSLG C78.377-2011 Specifications for the Chromaticity of Solid State Lighting Products ANSI C78.5-2003 Specifications for Performance of Self-ballasted Compact Fluorescent Lamps ANSI/ANSLG C78.81-2010 Double-Capped Fluorescent Lamps—Dimensional and Electrical Characteristics ANSI C78.901-2014 Single-Based Fluorescent Lamps—Dimensional and Electrical Characteristics ANSI/ANSLG C81.61-2009 Specifications for Bases (Caps) for Electric Lamps ANSI/ANSLG C81.62-2009 Lamp holders for Electric Lamps ANSI C82.11-2011High-Frequency Fluorescent Lamp Ballasts ANSI/ANSLG C82.16-2015 (anticipated) Light Emitting Diode Drivers—Methods of Measurement ANSI C82.2-2002 Method of Measurement of Fluorescent Lamp Ballasts ANSI C82.77-10:2014 Harmonic Emission Limits—Related Power Quality Requirements for Lighting Equipment ANSI/IEEE C62.41.1-2002 IEEE Guide on the Surge Environment in Low-Voltage (1000 V and Less) AC Power Circuits ANSI/IEEE C62.41.2-2002 IEEE Recommended Practice on Characterization of Surges in Low-Voltage (1000V and Less) AC Power Circuits ANSI/UL 153-2002 Standard for Safety of Portable Electric Luminaires ANSI/UL 935-2009 Standard for Safety of Fluorescent-Lamp Ballasts ANSI/UL 1310-2010 Standard for Safety of Class 2 Power Units ANSI/UL 1574-2004 Standard for Safety of Track Lighting Systems ANSI/UL 1598-2008 Standard for Safety of Luminaires ANSI/UL 1598C Light-Emitting Diode (LED) Retrofit Luminaire Conversion Kits ANSI/UL 1598B-2010 Standard for Supplemental Requirements for Luminaire Reflector Kits for Installation on Previously Installed Fluorescent Luminaires ANSI/UL 1993-2009 Standard for Safety of Self-Ballasted Lamps and Lamp Adapters ANSI/UL 2108-2004 Standard for Low-Voltage Lighting Systems ANSI/UL 8750-2009 Standard for Light Emitting Diode (LED) Equipment for Use in Lighting Products ASTM E283-04 Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen CIE Pub. No. 13.3-1995 Method of Measuring and Specifying Color Rendering of Light Sources CIE Pub. No. 15:2004 Colorimetry EU Directive 2002/95/EC Directive 2002/95/EC of the European Parliament and of the Council of 27 January 2003 on the Restriction of the Use of Certain Hazardous Substances In Electrical and Electronic Equipment FCC CFR Title 47 Part 15 Radio Frequency Devices FCC CFR Title 47 Part 18 Industrial, Scientific, and Medical Equipment IEC 60061-1 (2012) Lamp Caps and Holders Together with Gauges for the Control of Interchangeability and Safety – Part 1: Lamp Caps IEC 60081 Amend 4 Ed 5.0 (2010) Double-capped Fluorescent Lamps - Performance Specifications IEC 60901 (2011) Single-capped Fluorescent Lamps - Performance Specifications IEC 62301 ED.2.0 B:2011 Household electrical appliances - Measurement of standby power IEC 61347-2-3-am2 ed1.0 b.2011 Amendment 2 - Lamp Control Gear - Part 2-3: Particular Requirements for A.C. Supplied Electronic Ballasts for Fluorescent Lamps IEC 62321 Ed. 1.0 Electrotechnical Products - Determination Of Levels Of Six Regulated Substances (lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, polybrominated diphenyl ethers) IEEE PAR1789 IEEE Recommending Practices for Modulating Current in High Brightness LEDs for Mitigating Health Risks to Viewers IES LM-9-09 Electric and Photometric Measurements of Fluorescent Lamps IES LM-10-96 or LM-10-XX Photometric Testing of Outdoor Fluorescent Luminaires (2015 update anticipated) IES LM-31-95 Photometric Testing of Roadway Luminaires Using Incandescent Filament and High Intensity Discharge (HID) Lamps IES LM-40-10 Life Testing of Fluorescent Lamps IES LM-41-14 Approved Method for Photometric Testing of Indoor Fluorescent Luminaries IES LM-46-04 Photometric Testing of Indoor Luminaires Using High Intensity Discharge or Incandescent Filament Lamps IES LM-49-12 Life Testing of Incandescent Filament Lamps IES LM-58-13 Method for Spectroradiometric Measurement Methods for Light Sources IES LM-65-14 Life Testing of Compact Fluorescent Lamps IES LM-66-14 Electrical and Photometric Measurements of Single-Ended Compact Fluorescent Lamps IES LM-79-08 Electrical and Photometric Measurements of Solid-State Lighting Products IES LM-80-08 Measuring Lumen Maintenance of LED Light Sources IES LM-82-12 Method for the Characterization of LED Light Engines and Integrated LED Lamps for Electrical and Photometric Properties as a Function of Temperature IES LM-84-14 Measuring Luminous Flux and Color Maintenance of LED Lamps, Light Engines, and Luminaires IES RP-16-10 Nomenclature and Definitions for Illuminating Engineering IES TM-21-11 Projecting Long Term Lumen Maintenance of LED Sources IES TM-28-14 Projecting Long-Term Luminous Flux Maintenance of LED Lamps and Luminaries NEMA LL 9-2009 Dimming of T8 Fluorescent Lighting Systems NEMA LSD 45-2009 Recommendations for Solid State Lighting Sub-Assembly Interfaces for Luminaires NEMA SSL 7A-2013 Phase Cut Dimming for Solid State Lighting: Basic Compatibility
Shanghai Supertek Lighting Co., Ltd. Basic Model: WP07B-100-4000K
Report No.BTR66.181.16.0028.14 Page 4 of 10 DLC V4.1 Test Report
Initial Photometric and Electrical Test Data
EUT Input
Voltage (V)
Frequency (Hz)
Input Current (A) ITHD Input Power
(W) Power Factor Lumen Output
(Lumens)
Efficiency Lumen/w
WP07B-100-4000K 120.0 60.0 0.872 7.1% 104.10 0.995 12406.00 119.17
WP07B-100-4000K 277.0 60.0 0.399 12.8% 103.90 0.940 / /
EUT CCT (K)
CRI Ra R9 x
CIE1931 y
CIE1931
WP07B-100-4000K 4041 73.5 -18 0.3767 0.3684
WP07B-100-5000K 5189 75.1 -15 0.3399 0.3445
EUT u' CIE1976
v' CIE1976 Duv Rf Rg
WP07B-100-4000K 0.2260 0.4973 -0.0029 71 95
WP07B-100-5000K 0.2106 0.4804 -0.0015 72 95
EUT Zonal Lumen Density zone (0-90°) Zonal Lumen Density zone (80-90°)*
WP07B-100-4000K 100.0% 0.5%
Note: 1. See the annex of Luminous Intensity Distribution Test Plots
Shanghai Supertek Lighting Co., Ltd. Basic Model: WP07B-100-4000K
Report No.BTR66.181.16.0028.14 Page 5 of 10 DLC V4.1 Test Report
7 Step Quadrangle WP07B-100-4000K WP07B-100-5000K
Shanghai Supertek Lighting Co., Ltd. Basic Model: WP07B-100-4000K
Report No.BTR66.181.16.0028.14 Page 6 of 10 DLC V4.1 Test Report
Spectral Energy Distribution WP07B-100-4000K
WL(nm) Spectrum Spectrum WL(nm) Spectrum Spectrum
380 0.0244 5.3720 585 0.8414 184.9000
385 0.0157 3.4560 590 0.8342 183.3000
390 0.0109 2.3980 595 0.8190 180.0000
395 0.0090 1.9690 600 0.7962 175.0000
400 0.0097 2.1240 605 0.7670 168.6000
405 0.0139 3.0520 610 0.7322 160.9000
410 0.0270 5.9310 615 0.6914 152.0000
415 0.0539 11.8400 620 0.6479 142.4000
420 0.1030 22.6400 625 0.6007 132.0000
425 0.1772 38.9300 630 0.5557 122.1000
430 0.2870 63.0800 635 0.5079 111.6000
435 0.4439 97.5500 640 0.4614 101.4000
440 0.6426 141.2000 645 0.4160 91.4200
445 0.8892 195.4000 650 0.3737 82.1300
450 0.9857 216.6000 655 0.3342 73.4600
455 0.7350 161.5000 660 0.2971 65.2900
460 0.4646 102.1000 665 0.2626 57.7000
465 0.3300 72.5300 670 0.2312 50.8000
470 0.2290 50.3200 675 0.2031 44.6500
475 0.1596 35.0700 680 0.1783 39.1900
480 0.1327 29.1600 685 0.1560 34.2900
485 0.1285 28.2400 690 0.1365 30.0000
490 0.1424 31.3000 695 0.1194 26.2500
495 0.1793 39.4100 700 0.1038 22.8200
500 0.2346 51.5600 705 0.0898 19.7300
505 0.2984 65.5900 710 0.0780 17.1400
510 0.3661 80.4600 715 0.0677 14.8800
515 0.4304 94.6000 720 0.0589 12.9500
520 0.4878 107.2000 725 0.0511 11.2400
525 0.5355 117.7000 730 0.0442 9.7040
530 0.5800 127.5000 735 0.0384 8.4440
535 0.6158 135.3000 740 0.0336 7.3770
540 0.6511 143.1000 745 0.0292 6.4170
545 0.6829 150.1000 750 0.0255 5.6140
550 0.7131 156.7000 755 0.0222 4.8890
555 0.7424 163.2000 760 0.0195 4.2960
560 0.7707 169.4000 765 0.0172 3.7890
565 0.7964 175.0000 770 0.0151 3.3290
570 0.8165 179.4000 775 0.0134 2.9370
575 0.8312 182.7000 780 0.0125 2.7370
580 0.8403 184.7000
Shanghai Supertek Lighting Co., Ltd. Basic Model: WP07B-100-4000K
Report No.BTR66.181.16.0028.14 Page 7 of 10 DLC V4.1 Test Report
WP07B-100-5000K
WL(nm) Spectrum Spectrum WL(nm) Spectrum Spectrum
380 0.0204 4.6360 585 0.5769 130.8000
385 0.0156 3.5370 590 0.5645 128.0000
390 0.0103 2.3360 595 0.5474 124.1000
395 0.0089 2.0140 600 0.5261 119.3000
400 0.0092 2.0770 605 0.5003 113.4000
405 0.0116 2.6280 610 0.4728 107.2000
410 0.0213 4.8400 615 0.4422 100.3000
415 0.0433 9.8160 620 0.4121 93.4500
420 0.0819 18.5700 625 0.3791 85.9700
425 0.1456 33.0200 630 0.3482 78.9600
430 0.2393 54.2600 635 0.3165 71.7700
435 0.3689 83.6600 640 0.2863 64.9200
440 0.5502 124.8000 645 0.2584 58.5800
445 0.8014 181.7000 650 0.2317 52.5400
450 0.9979 226.3000 655 0.2055 46.5900
455 0.8537 193.6000 660 0.1831 41.5200
460 0.5544 125.7000 665 0.1613 36.5700
465 0.3825 86.7300 670 0.1424 32.3000
470 0.2727 61.8400 675 0.1251 28.3600
475 0.1864 42.2600 680 0.1092 24.7700
480 0.1435 32.5500 685 0.0958 21.7300
485 0.1307 29.6300 690 0.0841 19.0700
490 0.1365 30.9600 695 0.0732 16.6000
495 0.1624 36.8300 700 0.0639 14.4900
500 0.2090 47.4000 705 0.0555 12.6000
505 0.2653 60.1400 710 0.0482 10.9200
510 0.3244 73.5500 715 0.0417 9.4460
515 0.3801 86.1900 720 0.0364 8.2590
520 0.4280 97.0400 725 0.0318 7.2030
525 0.4669 105.9000 730 0.0275 6.2350
530 0.4959 112.4000 735 0.0241 5.4650
535 0.5191 117.7000 740 0.0207 4.7020
540 0.5371 121.8000 745 0.0183 4.1600
545 0.5520 125.2000 750 0.0160 3.6390
550 0.5628 127.6000 755 0.0141 3.2050
555 0.5742 130.2000 760 0.0123 2.7930
560 0.5820 132.0000 765 0.0110 2.4880
565 0.5874 133.2000 770 0.0095 2.1620
570 0.5910 134.0000 775 0.0086 1.9560
575 0.5891 133.6000 780 0.0077 1.7410
580 0.5859 132.9000
Shanghai Supertek Lighting Co., Ltd. Basic Model: WP07B-100-4000K
Report No.BTR66.181.16.0028.14 Page 8 of 10 DLC V4.1 Test Report
Driver Case Temperature/ LED Drive Current/TMPLED Test Data
EUT Driver Max Tc (℃)
Driver In-Situ Temperature
(℃)
LED In-Situ Current
(mA)
LED In-Situ Temperature
(℃)(1#)
LED In-Situ Temperature
(℃)(2#)
LED In-Situ Temperature
(℃)(3#)
WP07B-100-4000K N/A N/A 122.0 86.4 86.8 84.9
LED Lighting Source Temperature Measurement Point in LM-80 Report LED Lighting Source In Situ Temperature Measurement
LED 1
LED 2
LED 3
Shanghai Supertek Lighting Co., Ltd. Basic Model: WP07B-100-4000K
Report No.BTR66.181.16.0028.14 Page 9 of 10 DLC V4.1 Test Report
TOP: LED 2 Lumen Maintenance and Lighting Source Life Test Data L70
Shanghai Supertek Lighting Co., Ltd. Basic Model: WP07B-100-4000K
Report No.BTR66.181.16.0028.14 Page 10 of 10 DLC V4.1 Test Report
EUT Photos
BEST TEST SERVICE SHENZHEN CO.,LTD
STREETLIGHT PHOTOMETRIC TEST REPORT
NAME:
SPEC.:
MFR.: Supertek
TYPE:WP07B-100-4000K
DIM.:
SUR.:
WEIGHT:
SERIAL No.:
PROTECTION ANGLE:
Test:U:120.0V I:0.8719A P:104.1W PF:0.9950 Lamp Flux:12406x1 lm
0
30
60
90
120
150
-/+180
-150
-120
-90
-60
-30
UNIT:cdC0/180,101.8deg
UNIT:cd
C90/270,83.0deg
AVERAGE BEAM ANGLE(50%):92.4 DEG
0
1300
2600
3900
5200
6500
INTENSITY DISTRIBUTION DIAGRAMIN C PLANS
MAX INTENSITY CONE SURFACEDISTRIBUTION DIAGRAM
C0
C30
C60
C90
C120
C150
C180
C210
C240
C270
C300
C330
Max @ = 25.0DEG
HOUSE SIDE
STREET SIDE
0
1300
2600
3900
5200
6500
DATA OF LAMP PHOTOMETRIC DATA Eff: 119.17 lm/W
MODEL
NOMINAL POWER(W)
RATED VOLTAGE(V)
NOMINAL FLUX(lm)
LAMPS INSIDE
TEST VOLTAGE(V)
Imax(cd)
LOR(%)
TOTAL FLUX(lm)
MAXIMUM @(C, )
up(%)
down(%)
street_up(%)
street_down(%)
house_up(%)
house_down(%)
76 FLASHAREA(m2)
SLI
WP07B-100-4000K
100
120.0
12406
1
120.0
6081
100.0
12406
80,25.0
0.0
100.0
0.0
56.6
0.0
43.4
C Range: 0 - 360DEGC Interval: 10.0DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.287Temperature:25.6DEG Humidity:67.1%
Test Distance:2.543m [K=1.0000]Operators:DavidTest Date:2017-04-11 Remarks:
Note: SLI:Specific Luminaire Index
BEST TEST SERVICE SHENZHEN CO.,LTD
STREETLIGHT ISOCANDELA DIAGRAM
NAME:
SPEC.:
MFR.: Supertek
TYPE:WP07B-100-4000K
DIM.:
SUR.:
WEIGHT:
SERIAL No.:
PROTECTION ANGLE:
Test:U:120.0V I:0.8719A P:104.1W PF:0.9950 Lamp Flux:12406x1 lm
15345 30330 45315 60300 75285 90270 C0
180
10
170
20
160
30
150
40
140
50
130
60
120
70
110
80
100
90
Classification:
IES:Type II - Very ShortCIE:Narrow - Short
CIE:Full cut-offIES:Cut-off
Max.At80:26.54cd/klmMax.At90:2.078cd/klmMax.80-90:26.54cd/klm
ISOCANDELA DIAGRAM
UNIT cd
Imax=100% 6081
90% 5473
80% 4865
70% 4257
60% 3649
50% 3041
40% 2433
30% 1824
20% 1216
10% 608
5% 304
C Range: 0 - 360DEGC Interval: 10.0DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.287Temperature:25.6DEG Humidity:67.1%
Test Distance:2.543m [K=1.0000]Operators:DavidTest Date:2017-04-11 Remarks:
BEST TEST SERVICE SHENZHEN CO.,LTD
COEFFICIENT OF UTILIZATION CURVEAND ISOLUX DIAGRAM
2 1 0 1 2 3 4STREET SIDEHOUSE SIDE RATIO OF DISTANCE TO MOUNTING HEIGHT
0
10
20
30
40
50
60
70
80
90
100STREETLIGHT COEFFICIENT OF UTILIZATION CURVECU(%)
TILT ANGLE 0.0(DEG)
5.0(DEG)
10.0(DEG)
15.0(DEG)
20.0(DEG)
-7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 74
3
2
1
0
1
RATIO OF DISTANCE TO MOUNTING HEIGHT
STREET SIDE D/MH HOUSE SIDE
45 34 28 22 175.6 2.8 1.7 0.56 0.28
ROAD SURFACE ISOLUX DIAGRAMILLUMINANCE AT MH=10 m,Enadir = 55.97 lx
TO CONVERT TO OTHER MH,MULTIPLY BY FACTOR IN THE TABLE.
HEIGHT FACTOR
5 m 4.000
6 m 2.778
7 m 2.041
8 m 1.563
9 m 1.235
10 m 1.000
11 m 0.826
12 m 0.694
13 m 0.592
14 m 0.510
15 m 0.444
16 m 0.391
C Range: 0 - 360DEGC Interval: 10.0DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.287Temperature:25.6DEG Humidity:67.1%
Test Distance:2.543m [K=1.0000]Operators:DavidTest Date:2017-04-11 Remarks:
BEST TEST SERVICE SHENZHEN CO.,LTD
ZONAL FLUX DIAGRAM
NAME:
SPEC.:
MFR.: Supertek
TYPE:WP07B-100-4000K
DIM.:
SUR.:
WEIGHT:
SERIAL No.:
PROTECTION ANGLE:
Test:U:120.0V I:0.8719A P:104.1W PF:0.9950 Lamp Flux:12406x1 lm
10 0- 10
20 10- 20
30 20- 30
40 30- 40
50 40- 50
60 50- 60
70 60- 70
80 70- 80
90 80- 90
100 90-100
110 100-110
120 110-120
130 120-130
140 130-140
150 140-150
160 150-160
170 160-170
180 170-180
C0 C45 C90 C135 C180 C225 C270 C315 zone total %lum
DEG LUMINOUS INTENSITY:cd UNIT:lm
5548 5906 5915 5766 5381 4959 4828 5051 525.4 525.4 4.24
5270 5767 5972 5447 4872 4163 4002 4353 1469 1994 16.1
4807 5443 5777 5030 4261 3317 3352 3623 2181 4176 33.7
4188 4950 4018 4376 3533 2698 2779 3047 2564 6740 54.3
3268 3938 2566 3042 2597 1912 1626 2315 2424 9164 73.9
2068 2521 1397 1666 1511 800.0 739.3 1173 1796 10960 88.3
951.7 1174 560.0 629.1 593.2 297.0 552.4 438.6 994.6 11954 96.4
190.1 285.1 83.52 70.73 65.51 92.94 254.7 190.7 387.9 12342 99.5
6.573 0.0334 0.0361 0.0373 0.0082 0.0932 15.53 19.71 61.93 12404 100
0.0217 0.0213 0.0414 0.0511 0.0358 0.0479 0.0200 0.0243 0.6493 12405 100
0.0745 0.0476 0.0618 0.0979 0.1024 0.1221 0.0611 0.0714 0.0517 12405 100
0.1583 0.1069 0.1090 0.1707 0.1958 0.2207 0.1302 0.1493 0.1164 12405 100
0.2142 0.1488 0.1497 0.2183 0.3002 0.3396 0.2390 0.2568 0.1722 12405 100
0.3292 0.2470 0.2433 0.3036 0.3383 0.3814 0.3303 0.3168 0.2102 12405 100
0.4761 0.3855 0.3671 0.4220 0.3735 0.4196 0.3949 0.3742 0.2217 12406 100
0.5644 0.4919 0.4673 0.5127 0.4441 0.4808 0.4726 0.4520 0.2053 12406 100
0.6763 0.6518 0.6389 0.6537 0.4585 0.4745 0.4720 0.4664 0.1498 12406 100
0.4276 0.4224 0.4353 0.4074 0.4244 0.4289 0.4244 0.4187 0.0441 12406 100
C Range: 0 - 360DEGC Interval: 10.0DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.287Temperature:25.6DEG Humidity:67.1%
Test Distance:2.543m [K=1.0000]Operators:DavidTest Date:2017-04-11 Remarks:
BEST TEST SERVICE SHENZHEN CO.,LTD
ISOCANDELA DIAGRAM
NAME:
SPEC.:
MFR.: Supertek
TYPE:WP07B-100-4000K
DIM.:
SUR.:
WEIGHT:
SERIAL No.:
PROTECTION ANGLE:
Test:U:120.0V I:0.8719A P:104.1W PF:0.9950 Lamp Flux:12406x1 lm
-90-90
-80
-80
-70
-70
-60
-60
-50
-50
-40
-40
-30
-30
-20
-20
-10
-10
0
0
10
10
20
20
30
30
40
40
50
50
60
60
70
70
80
80
90
90
HORIZONTAL(DEG)
VERTICAL(DEG)
Imax:6078(H4.0,V-24.5) (At:C=80.0,Gamma=25.0)
UNIT: cd
10% 607.820% 121630% 182440% 243150% 303960% 364770% 425580% 486390% 5471
Conical surface Flux(90deg):8005.9 lm%lum = 64.5%%lamp = 64.5%
Conical surface Flux(120deg):10960 lm%lum = 88.3%%lamp = 88.3%
C Range: 0 - 360DEGC Interval: 10.0DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.287Temperature:25.6DEG Humidity:67.1%
Test Distance:2.543m [K=1.0000]Operators:DavidTest Date:2017-04-11 Remarks:
BEST TEST SERVICE SHENZHEN CO.,LTD
Planar Illuminance Curve
Planar Illuminance Curve
-10 -8 -6 -4 -2 0 2 4 6 8 10
Distance(m)
0
6
12
18
24
30
36
42
48
54
60E(lx) MH = 10 m
C0/180
C90/270
C Range: 0 - 360DEGC Interval: 10.0DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.287Temperature:25.6DEG Humidity:67.1%
Test Distance:2.543m [K=1.0000]Operators:DavidTest Date:2017-04-11 Remarks:
BEST TEST SERVICE SHENZHEN CO.,LTD
LUMINOUS DISTRIBUTION INTENSITY DATA
NAME:
SPEC.:
MFR.: Supertek
TYPE:WP07B-100-4000K
DIM.:
SUR.:
WEIGHT:
SERIAL No.:
PROTECTION ANGLE:
Test:U:120.0V I:0.8719A P:104.1W PF:0.9950 Lamp Flux:12406x1 lm
(DEG)
C(DEG) Table--1 UNIT: cd
0
0 5598
5 5605
10 5548
15 5431
20 5270
25 5064
30 4807
35 4514
40 4188
45 3787
50 3268
55 2654
60 2068
65 1512
70 952
75 503
80 190
85 59.3
90 6.57
95 0.01
100 0.02
105 0.03
110 0.07
115 0.13
120 0.16
125 0.19
130 0.21
135 0.27
140 0.33
145 0.40
150 0.48
155 0.53
160 0.56
165 0.60
170 0.68
175 0.45
180 0.43
10
5597
5653
5644
5570
5444
5272
5063
4823
4525
4129
3609
2983
2359
1812
1221
707
299
71.6
3.69
0.01
0.02
0.02
0.06
0.11
0.14
0.17
0.20
0.25
0.31
0.38
0.45
0.51
0.55
0.58
0.67
0.45
0.43
20
5597
5696
5727
5686
5608
5465
5240
4981
4624
4195
3650
2996
2330
1731
1135
637
290
79.0
4.58
0.01
0.02
0.02
0.06
0.10
0.13
0.15
0.18
0.23
0.29
0.35
0.43
0.49
0.53
0.57
0.67
0.45
0.43
30
5596
5736
5802
5817
5697
5512
5285
4993
4597
4130
3629
3056
2393
1776
1223
716
329
78.5
0.03
0.02
0.02
0.02
0.05
0.09
0.11
0.14
0.16
0.22
0.27
0.33
0.41
0.47
0.51
0.56
0.66
0.45
0.43
40
5596
5768
5880
5857
5733
5582
5332
5059
4832
4396
3903
3279
2580
1892
1250
733
321
61.7
0.04
0.02
0.02
0.02
0.05
0.09
0.11
0.13
0.15
0.20
0.25
0.32
0.39
0.45
0.50
0.55
0.65
0.45
0.43
50
5597
5794
5931
5874
5801
5656
5554
5406
5069
4612
3974
3242
2461
1742
1098
599
249
53.0
0.02
0.02
0.02
0.02
0.05
0.08
0.10
0.13
0.15
0.19
0.24
0.31
0.38
0.44
0.49
0.54
0.65
0.45
0.42
60
5596
5816
5941
5902
5848
5843
5819
5505
5068
4310
3417
2660
1971
1345
820
450
179
17.5
0.02
0.02
0.03
0.03
0.05
0.08
0.10
0.12
0.14
0.19
0.24
0.30
0.37
0.43
0.48
0.53
0.65
0.44
0.42
70
5596
5831
5936
5924
5916
6009
5844
5466
4659
3735
2973
2307
1675
1103
678
364
127
7.30
0.03
0.03
0.03
0.03
0.05
0.08
0.10
0.12
0.14
0.19
0.23
0.30
0.37
0.43
0.47
0.52
0.64
0.44
0.43
80
5597
5839
5928
5934
5971
6081
5832
5234
4250
3415
2721
2090
1492
964
599
306
98.4
7.21
0.03
0.03
0.04
0.04
0.06
0.09
0.10
0.12
0.15
0.19
0.24
0.30
0.37
0.42
0.47
0.52
0.64
0.44
0.43
90
5596
5838
5915
5918
5972
6044
5777
5043
4018
3241
2566
1981
1397
905
560
276
83.5
2.84
0.04
0.04
0.04
0.04
0.06
0.09
0.11
0.13
0.15
0.20
0.24
0.30
0.37
0.42
0.47
0.52
0.64
0.44
0.44
100
5596
5826
5893
5884
5913
5961
5699
4980
3969
3200
2515
1920
1336
861
527
252
68.3
3.69
0.04
0.04
0.04
0.04
0.07
0.10
0.11
0.13
0.16
0.20
0.25
0.30
0.37
0.43
0.47
0.52
0.64
0.43
0.43
110
5595
5806
5863
5833
5799
5832
5576
5020
4086
3227
2526
1883
1305
821
489
227
61.2
0.17
0.04
0.04
0.05
0.05
0.07
0.10
0.12
0.15
0.17
0.21
0.26
0.31
0.38
0.43
0.48
0.53
0.64
0.44
0.42
120
5595
5777
5828
5756
5651
5621
5403
5035
4347
3404
2607
1959
1359
860
504
235
60.0
0.13
0.04
0.04
0.05
0.05
0.08
0.12
0.14
0.16
0.19
0.23
0.27
0.33
0.39
0.45
0.49
0.54
0.65
0.44
0.41
130
5595
5742
5791
5671
5504
5347
5205
4917
4464
3781
2923
2199
1543
987
563
261
66.8
0.12
0.04
0.05
0.05
0.06
0.10
0.14
0.16
0.19
0.21
0.25
0.29
0.35
0.41
0.46
0.50
0.55
0.65
0.44
0.41
140
5593
5701
5741
5584
5390
5105
4855
4655
4288
3759
3162
2472
1788
1184
695
320
74.7
0.12
0.04
0.04
0.05
0.06
0.10
0.15
0.18
0.21
0.23
0.27
0.31
0.37
0.43
0.49
0.52
0.57
0.66
0.44
0.41
150
5593
5661
5657
5512
5262
4998
4641
4310
3885
3422
2941
2356
1757
1159
685
323
77.5
0.15
0.03
0.03
0.04
0.05
0.10
0.15
0.18
0.21
0.23
0.28
0.33
0.39
0.46
0.51
0.54
0.58
0.67
0.44
0.40
160
5591
5614
5549
5420
5165
4866
4557
4205
3703
3202
2683
2148
1575
1065
644
301
74.3
0.19
0.02
0.02
0.03
0.04
0.10
0.16
0.19
0.22
0.24
0.30
0.35
0.41
0.48
0.54
0.57
0.60
0.67
0.44
0.40
170
5590
5568
5457
5262
5027
4766
4451
4107
3677
3201
2666
2063
1490
1018
575
253
68.0
3.72
0.02
0.02
0.03
0.05
0.11
0.17
0.20
0.23
0.26
0.32
0.38
0.44
0.51
0.56
0.59
0.61
0.68
0.44
0.39
180
5598
5529
5381
5153
4872
4570
4261
3933
3533
3087
2597
2018
1511
1056
593
258
65.5
1.93
0.01
0.02
0.04
0.06
0.10
0.15
0.20
0.25
0.30
0.32
0.34
0.35
0.37
0.40
0.44
0.49
0.46
0.36
0.42
C Range: 0 - 360DEGC Interval: 10.0DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.287Temperature:25.6DEG Humidity:67.1%
Test Distance:2.543m [K=1.0000]Operators:DavidTest Date:2017-04-11 Remarks:
BEST TEST SERVICE SHENZHEN CO.,LTD
LUMINOUS DISTRIBUTION INTENSITY DATA
NAME:
SPEC.:
MFR.: Supertek
TYPE:WP07B-100-4000K
DIM.:
SUR.:
WEIGHT:
SERIAL No.:
PROTECTION ANGLE:
Test:U:120.0V I:0.8719A P:104.1W PF:0.9950 Lamp Flux:12406x1 lm
(DEG)
C(DEG) Table--2 UNIT: cd
190
0 5597
5 5483
10 5289
15 5021
20 4692
25 4332
30 3990
35 3661
40 3261
45 2803
50 2290
55 1726
60 1258
65 802
70 439
75 176
80 58.2
85 4.13
90 0.01
95 0.02
100 0.04
105 0.07
110 0.11
115 0.16
120 0.21
125 0.27
130 0.32
135 0.35
140 0.36
145 0.37
150 0.39
155 0.42
160 0.45
165 0.50
170 0.46
175 0.37
180 0.42
200
5597
5431
5178
4856
4480
4109
3746
3409
3001
2548
2079
1576
1177
709
321
155
62.5
7.57
0.01
0.03
0.05
0.08
0.12
0.17
0.22
0.28
0.34
0.36
0.37
0.39
0.41
0.43
0.47
0.51
0.47
0.36
0.43
210
5596
5378
5075
4723
4342
3950
3548
3190
2798
2388
1989
1544
1024
568
282
169
77.0
15.3
0.02
0.03
0.05
0.08
0.13
0.17
0.23
0.29
0.34
0.37
0.38
0.40
0.42
0.44
0.47
0.52
0.47
0.36
0.43
220
5596
5332
4987
4627
4220
3787
3374
3007
2728
2377
1980
1378
832
459
296
183
87.2
21.3
0.04
0.03
0.05
0.08
0.13
0.17
0.22
0.29
0.34
0.37
0.39
0.40
0.42
0.45
0.48
0.52
0.47
0.36
0.43
230
5597
5298
4930
4545
4106
3670
3260
2918
2669
2359
1844
1239
768
429
298
191
98.6
27.0
0.15
0.03
0.05
0.08
0.12
0.17
0.22
0.28
0.33
0.36
0.38
0.39
0.42
0.45
0.48
0.53
0.47
0.36
0.43
240
5596
5264
4886
4472
4037
3610
3235
2918
2638
2252
1648
1180
655
468
356
241
134
42.5
0.33
0.02
0.04
0.06
0.10
0.15
0.20
0.26
0.32
0.35
0.37
0.39
0.41
0.44
0.48
0.53
0.47
0.36
0.43
250
5596
5240
4851
4431
4002
3602
3262
2973
2657
2143
1541
1208
656
519
430
305
178
63.7
2.11
0.02
0.03
0.05
0.08
0.12
0.17
0.23
0.29
0.33
0.36
0.38
0.40
0.44
0.48
0.52
0.47
0.36
0.43
260
5597
5231
4829
4409
3992
3617
3312
3045
2709
2139
1559
1197
692
588
496
370
221
86.5
5.82
0.04
0.02
0.04
0.07
0.10
0.14
0.20
0.26
0.31
0.34
0.37
0.40
0.44
0.48
0.52
0.47
0.36
0.43
270
5596
5232
4828
4410
4002
3641
3352
3110
2779
2190
1626
1251
739
644
552
412
255
107
15.5
0.09
0.02
0.04
0.06
0.09
0.13
0.18
0.24
0.29
0.33
0.36
0.39
0.43
0.47
0.52
0.47
0.36
0.42
280
5596
5242
4844
4433
4032
3672
3387
3153
2843
2266
1689
1286
769
668
585
444
280
124
25.8
0.14
0.02
0.03
0.06
0.09
0.12
0.17
0.23
0.28
0.32
0.36
0.39
0.43
0.47
0.52
0.47
0.36
0.42
290
5595
5261
4882
4482
4081
3719
3428
3187
2914
2392
1776
1416
791
655
576
433
276
128
25.1
0.16
0.02
0.03
0.06
0.09
0.12
0.17
0.23
0.28
0.32
0.35
0.39
0.43
0.47
0.52
0.47
0.36
0.42
300
5595
5292
4942
4557
4164
3790
3472
3220
2970
2553
1934
1457
885
608
518
400
255
120
25.3
0.15
0.02
0.03
0.06
0.09
0.13
0.18
0.24
0.28
0.32
0.35
0.38
0.42
0.46
0.51
0.47
0.36
0.42
310
5595
5336
5012
4653
4278
3900
3554
3267
3014
2720
2179
1539
1147
601
455
332
207
100.0
21.9
0.11
0.02
0.04
0.07
0.10
0.14
0.20
0.25
0.29
0.32
0.35
0.38
0.42
0.46
0.51
0.47
0.36
0.42
320
5593
5378
5089
4780
4428
4059
3691
3366
3079
2812
2451
1808
1200
690
423
284
174
80.7
17.5
0.06
0.03
0.05
0.08
0.11
0.15
0.21
0.26
0.29
0.32
0.34
0.37
0.40
0.45
0.50
0.46
0.36
0.42
330
5593
5431
5191
4923
4616
4267
3907
3552
3214
2895
2569
2102
1451
911
466
287
174
78.6
16.1
0.02
0.03
0.05
0.08
0.11
0.16
0.21
0.26
0.29
0.31
0.33
0.36
0.40
0.44
0.49
0.46
0.36
0.41
340
5591
5487
5314
5068
4804
4523
4199
3842
3476
3079
2650
2188
1754
1164
636
295
166
73.1
13.7
0.01
0.02
0.04
0.07
0.11
0.15
0.20
0.25
0.28
0.31
0.33
0.36
0.39
0.43
0.48
0.46
0.36
0.41
350
5590
5546
5429
5256
5036
4758
4460
4146
3799
3382
2893
2334
1819
1355
874
369
157
61.0
7.79
0.01
0.02
0.04
0.07
0.11
0.15
0.20
0.25
0.28
0.30
0.32
0.35
0.39
0.43
0.48
0.46
0.37
0.41
C Range: 0 - 360DEGC Interval: 10.0DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.287Temperature:25.6DEG Humidity:67.1%
Test Distance:2.543m [K=1.0000]Operators:DavidTest Date:2017-04-11 Remarks:
0 1020
30
40
50
60
70
80
90270
280
290
300
310
320
330340
350
C=0
C=90
C=180
C=270
650
1300
1950
2600
3250
3900
4550
5200
5850
6500
I(cd)
0 1020
30
40
50
60
70
80
90270
280
290
300
310
320
330340
350
650
1300
1950
2600
3250
3900
4550
5200
5850
6500
FLUX DATA:
LOR:STREET DOWN:STREET UP:HOUSE DOWN:HOUSE UP:
100.0 %7017 lm1.180 lm5387 lm
0.6404 lm
C
15345 30330 45315 60300 75285 90270 C0
r
0 10102020
3030
4040
5050
6060
7070
8080
9090
0% 80%0% 60%
50%
40%
30%
20%
10%
100%
Imax(100%) = 6081 cd